Corning® Permeability/EVOM™ Compatibility Chart
WPI offers Corning® permeable membrane cell culture inserts and HTS Plates to grow epithelial and endothelial cells mimicking in vivo like condition. The formation of functional in vitro tissues or cell layers can be evaluated by measuring Transepithelial/ transendothelial (TEER) using WPI's EVOM™ instruments, the gold standard for the evaluation of effective cellular barrier formation. Use the table below to see which plates are compatible with which WPI TEER systems and electrodes.
|
Order Code |
Corning P/N | Option | Case of | Compatible with EVOM™ Manual | Compatible with EVOM™ Auto | |||
|
Meter |
Electrode |
System | Electrode | Notes | ||||
|
Corning® HTS Transwell® 96 Permeable Support with 8.0 µm Pore Polyester Membrane, Sterile |
||||||||
| EVM-AC-03-C3374 | 3374 | 2 |
EVOM™ Manual (EVM-MT-03-02, EVM-MT-03-01, EVOM3), EVOM2 (when used with the compatible electrode) |
STX HTS EVOM™ Electrode for CORNING 96 (EVM-EL-03-03-05) |
EVOM™ AUTO - 24/96 HTS Plate (EVA-MT-03-01, includes electrode) |
96 HTS Electrode Array (EVA-EL-03-01) |
||
| EVM-AC-03-C3384 | 3384 | 8 | ||||||
|
Corning® HTS Transwell® 24-well Permeable Support with 0.4 µm Pore Polyester Membrane and 6.5 mm Inserts, Sterile |
||||||||
| EVM-AC-03-C3378 | 3378 | 12 |
EVOM™ Manual (EVM-MT-03-02, EVM-MT-03-01, EVOM3), EVOM2 (when used with the compatible electrode) |
STX HTS EVOM™ Electrode for CORNING 24 (EVM-EL-03-03-04) |
EVOM™ AUTO - 24/96 HTS Plate (EVA-MT-03-02, includes electrode) |
24C HTS Electrode Array (EVA-EL-03-02)
|
||
| EVM-AC-03-C3379 | 3379 | 2 | ||||||
|
Corning® HTS Transwell® 96 Permeable Support with 1.0 microns Pore Polyester Membrane, Sterile |
||||||||
| EVM-AC-03-C3380 | 3380 | 1 |
EVOM™ Manual (EVM-MT-03-02, EVM-MT-03-01, EVOM3), EVOM2 (when used with the compatible electrode) |
STX HTS EVOM™ Electrode for CORNING 96 (EVM-EL-03-03-05) |
EVOM™ AUTO - 24/96 HTS Plate (EVA-MT-03-01, includes electrode) |
96 HTS Electrode Array (EVA-EL-03-01) |
||
| EVM-AC-03-C3392 | 3392 | 5 | ||||||
| Corning® HTS Transwell® 96 Permeable Support with 0.4 microns Pore Polycarbonate/PET Membrane, Sterile | ||||||||
| EVM-AC-03-C3381 | 3381 | 1 |
EVOM™ Manual (EVM-MT-03-02, EVM-MT-03-01, EVOM3), EVOM2 (when used with the compatible electrode) |
STX HTS EVOM™ Electrode for CORNING 96 (EVM-EL-03-03-05) |
EVOM™ AUTO - 24/96 HTS Plate (EVA-MT-03-01, includes electrode) |
96 HTS Electrode Array (EVA-EL-03-01) |
||
| EVM-AC-03-C3391 | 3391 | 5 | ||||||
| EVM-AC-03-C7369 | 7369 | 5 | ||||||
| Corning® HTS Transwell® 96 Permeable Support with 3.0 microns Pore Polycarbonate Membrane, Sterile | ||||||||
| EVM-AC-03-C3385 | 3385 | 2 |
EVOM™ Manual (EVM-MT-03-02, EVM-MT-03-01, EVOM3), EVOM2 (when used with the compatible electrode) |
STX HTS EVOM™ Electrode for CORNING 96 (EVM-EL-03-03-05) |
EVOM™ AUTO - 24/96 HTS Plate (EVA-MT-03-01, includes electrode) |
96 HTS Electrode Array (EVA-EL-03-01) |
||
| EVM-AC-03-C3386 | 3386 | 8 | ||||||
|
Corning® HTS Transwell® 96 Permeable Support with 5.0 microns Pore Polycarbonate Membrane, Sterile |
||||||||
| EVM-AC-03-C3387 | 3387 | 8 |
EVOM™ Manual (EVM-MT-03-02, EVM-MT-03-01, EVOM3), EVOM2 (when used with the compatible electrode) |
STX HTS EVOM™ Electrode for CORNING 96 (EVM-EL-03-03-05) |
EVOM™ AUTO - 24/96 HTS Plate (EVA-MT-03-01, includes electrode) |
96 HTS Electrode Array (EVA-EL-03-01) |
||
| EVM-AC-03-C3388 | 3388 | 2 | ||||||
| Corning® HTS Transwell® 24-well Permeable Support with 0.4 microns Pore Polycarbonate Membrane and 6.5 mm Inserts, Sterile | ||||||||
| EVM-AC-03-C3396 | 3396 | 2 |
EVOM™ Manual (EVM-MT-03-02, EVM-MT-03-01, EVOM3), EVOM2 (when used with the compatible electrode) |
STX HTS EVOM™ Electrode for CORNING 24 (EVM-EL-03-03-04) |
EVOM™ AUTO - 24/96 HTS Plate (EVA-MT-03-02, includes electrode) |
24C HTS Electrode Array (EVA-EL-03-02) |
||
| EVM-AC-03-C3397 | 3397 | 12 | ||||||
| Corning® 6.5/12/24 mm Transwell® with 0.4 microns Pore Polyester Membrane Insert, Sterile | ||||||||
| EVM-AC-03-C3450 | 3450 | 24 mm | 24 |
EVOM™ Manual (EVM-MT-03-02, EVM-MT-03-01, EVOM3), EVOM2
|
Not compatible with EVOM™ Auto |
|||
| EVM-AC-03-C3460 | 3460 | 12 mm | 48 | |||||
| EVM-AC-03-C3470 | 3470 | 6.5 mm, TCT | 48 |
Chopstick Electrode STX4 EVOM™ Manual Electrode |
EVOM™ AUTO for TEER Measurement In 24/96 HTS Plate (EVA-MT-03-03, includes electrode) |
24M HTS Electrode Array (EVA-EL-03) |
Requires Exchange Plate for 24 Well Inserts and inserts are moved to these plates for automated TEER |
|
|
Corning® 6.5 mm Transwell® with 0.4/3/8 microns Pore Polycarbonate Membrane Insert, Sterile |
||||||||
| EVM-AC-03-C3413 | 3413 | 0.4 µm Pore | 48 |
EVOM™ Manual (EVM-MT-03-02, EVM-MT-03-01, EVOM3), EVOM2
|
Chopstick Electrode STX4 EVOM™ Manual Electrode |
EVOM™ AUTO - 24/96 HTS Plate (EVA-MT-03-03, includes electrode) |
24M HTS Electrode Array (EVA-EL-03) |
Requires Exchange Plate for 24 Well Inserts and inserts are moved to these plates for automated TEER |
| EVM-AC-03-C3415 | 3415 | 3.0 µm Pore | 48 | |||||
| EVM-AC-03-C3422 | 3422 | 8.0 µm Pore | 48 | |||||
|
Corning® 24 mm Transwell® with 0.4/3.0 microns Pore Polycarbonate Membrane Insert, Sterile |
||||||||
| EVM-AC-03-C3412 | 3412 | 24 |
EVOM™ Manual (EVM-MT-03-02, EVM-MT-03-01, EVOM3), EVOM2
|
Not compatible |
||||
| EVM-AC-03-C3414 | 3414 | 24 | ||||||
|
Corning® HTS Transwell®-24-well Permeable Support with 3.0 microns Pore Polycarbonate Membrane and 6.5 mm Inserts, Sterile |
||||||||
| EVM-AC-03-C3398 | 3398 | 2 |
EVOM™ Manual (EVM-MT-03-02, EVM-MT-03-01, EVOM3), EVOM2 (when used with the compatible electrode) |
STX HTS EVOM™ Electrode for CORNING 96 (EVM-EL-03-03-05) |
EVOM™ AUTO - 24/96 HTS Plate (EVA-MT-03-01, includes electrode) |
96 HTS Electrode Array (EVA-EL-03-01) |
||
| EVM-AC-03-C3399 | 3399 | 12 | ||||||
| Costar® 6/12/24-well Clear TCT Individually Wrapped Plates (50) | ||||||||
| EVM-AC-03-C3513 | 3513 | 12-well | 50 |
Plates can be used as the base plate with Transwells or permeable membrane cell culture inserts. For EVOM™ measurement, Transwell® set up is required. Cells grown directly on the base plate cannot provide any TEER measurements. |
|
|
|
|
| EVM-AC-03-C3516 | 3516 | 6-well | 50 |
|
|
|
||
| EVM-AC-03-C3526 | 3526 | 24-well | 50 |
|
|
|
||
| Corning® 12 mm Transwell® with 0.4/3.0 microns Pore Polycarbonate Membrane Insert, Sterile | ||||||||
| EVM-AC-03-C3401 | 3401 | 0.4 µm Pore, PC | 48 |
EVOM™ Manual (EVM-MT-03-02, EVM-MT-03-01, EVOM3), EVOM2
|
Not compatible |
|||
| EVM-AC-03-C3407 | 3407 | 0.4 µm Pore, PC | 24 | |||||
| EVM-AC-03-C3462 | 3462 | 3.0 µm Pore, PET | 48 | |||||
| Corning® FluoroBlok™ HTS 96-well Multiwell Permeable Support System with 3.0/8.0 microns High Density PET Membrane, Sterile | ||||||||
| EVM-AC-03-C351161 | 351161 | 3.0 µm Pore | 1 |
|
|
EVOM™ AUTO - 24/96 HTS Plate (EVA-MT-03-01, includes electrode)
|
96 HTS Electrode Array (EVA-EL-03-01) |
|
| EVM-AC-03-C351162 | 351162 | 3.0 µm Pore | 5 |
|
|
|||
| EVM-AC-03-C351163 | 351163 | 8.0 µm Pore | 1 |
|
|
|||
| EVM-AC-03-C351164 | 351164 | 8.0 µm Pore | 5 |
|
|
|||
| Falcon® 24-well Multiwell Insert System with 1.0 microns Pore High Density PET Membrane, 5 Plates per Case | ||||||||
| EVM-AC-03-C351181 | 351181 |
EVOM™ Manual (EVM-MT-03-02, EVM-MT-03-01, EVOM3), EVOM2 (when used with the compatible electrode) |
STX HTS EVOM™ Electrode for Falcom (EVM-EL-03-03-03) |
EVOM™ AUTO - 24/96 HTS Plate (EVA-MT-03-02 includes electrode) |
24C HTS Electrode Array (EVA-EL-03-02) |
|||
| Corning® BioCoat® Control Inserts with 0.4 microns PET Membrane in two 24-well Plates, 12/Pack | ||||||||
| EVM-AC-03-C354572 | 354572 | 24 | EVOM™ Manual (EVM-MT-03-02, EVM-MT-03-01, EVOM3), EVOM2 older meters. |
Chopstick Electrode STX4 EVOM™ Manual Electrode |
EVOM™ AUTO - 24/96 HTS Plate (EVA-MT-03-03, includes electrode) |
24M HTS Electrode Array (EVA-EL-03) |
Requires Exchange Plate for 24 Well Inserts and inserts are moved to these plates for automated TEER | |
| Falcon® 96 Well/Square Well Insert Plate, Sterile, 5/Case | ||||||||
|
EVM-AC-03-C353938 |
353938 | 96 square well | 5 |
|
|
EVOM™ AUTO - 24/96 HTS Plate (EVA-MT-03-01, includes electrode) |
96 HTS Electrode Array (EVA-EL-03-01) |
|
|
EVM-AC-03-C351131 |
351131 | 96 well | 5 |
|
|
|||
EndOhm Chamber Compatibility
| Insert Size | Wells per Plate | For EVOM™ Manual/EVOM3 | For EVOM2 |
| 6 mm | 24 | EVM-EL-03-01-01 | ENDOHM-6G |
| 12 mm | 12 | EVM-EL-03-01-02 | ENDOHM-12G |
| 24 | 6 | EVM-EL-03-01-03 | ENDOHM-24G-SNAP |