VIDEO: What's the Difference between Hanging and Standing Cell Culture Inserts used in EndOhm Chambers
WPI EndOhm chambers are used with WPI's EVOM2 meter for making TEER (transepithelial electrical resistance) measurements. Here Subhra shows the difference between hanging cell culture inserts and standing cell culture inserts.
Sterile Disposable Rinse Stations for EVOM™ Auto Offer Convenience
The EVOM™ Auto automates measurements of TEER in epithelial or endothelial monolayers cultured on 24-well or 96-well high throughput screening (HTS) plates utilizing our innovative EVOM technology, qualitatively measuring cell monolayer health and quantitatively measuring cellular confluence by reaching an increase or a plateau in tissue resistance. The autosampler has a 3-well rinse station for cleaning and stabilizing the electrodes. Now, sterile disposable rinse station inserts are available for your convenience. They fit over the 3-well base rinse station. You can simply throw out the disposable inserts with the solutions when you are changing plates. This short videos shows how easy they are to use.
VIDEO: How to Remove EVOM™ Auto Electrode Array Lock
EVOM™ Auto, with both 24 and 96 HTS multiwell plate capability, is a high throughput screening (HTS) platform offering fast, noninvasive sample scanning by comparing electrical resistance measurements (transepithelial/transendothelial electrical resistance: TEER). TEER measurement experiments are simple to set up and less time consuming than more complex molecular studies. TEER measurement can be used as the primary scanning method to identify any physiological changes that can then be further evaluated by other methods. EVOM™ Auto can capture TEER measurements in 24 and 96 HTS multiwell plates from Corning, Millipore, or MatTek. The sample preparation time in these HTS plates is efficient, allowing for fast, multi-channel pipetting options.
The EVOM™ Auto autosampler ships with a red electrode array lock in place to prevent the electrode array connection port from moving during transit. Here you can see how to easily remove it without damaging the lock or the autosampler.
VIDEO: Why Upgrade Your EVOM2?
In 2022, the United States Food and Drug Administration (FDA) approved 37 new drugs, of which 20 were chemical entities and 17 were biologics. In 2023, drug discovery remains strong with many new advancements a result of changing landscapes in both the types of drugs that are being developed and the new and innovative assay that are being launched to evaluate drugs preclinically. Therapeutic development is still highly focused on diseases that affect large populations of people for which there are lack of effective treatments, with 2023’s most anticipated drug launches expected to be in areas of cancer, Alzheimer’s disease, cardiovascular disease, and ulcerative colitis.
Applications for TEER Measurement in Drug Discovery
In 2022, the United States Food and Drug Administration (FDA) approved 37 new drugs, of which 20 were chemical entities and 17 were biologics. In 2023, drug discovery remains strong with many new advancements a result of changing landscapes in both the types of drugs that are being developed and the new and innovative assay that are being launched to evaluate drugs preclinically. Therapeutic development is still highly focused on diseases that affect large populations of people for which there are lack of effective treatments, with 2023’s most anticipated drug launches expected to be in areas of cancer, Alzheimer’s disease, cardiovascular disease, and ulcerative colitis.
VIDEO: How to Schedule an Operation on the EVOM™ Auto
The EVOM™ Auto automates measurements of TEER in epithelial or endothelial monolayers cultured on high throughput screening 96-well plates utilizing our innovative EVOM™ technology, qualitatively measuring cell monolayer health and quantitatively measuring cell confluence by determining an increase or a plateau in tissue resistance.
The video below shows you how to schedule an operation on the EVOM™ Auto:
VIDEO: How to Stabilize the Electrode Array on the EVOM™ Auto
The EVOM™ Auto automates measurements of TEER in epithelial or endothelial monolayers cultured on high throughput screening 96-well plates utilizing our innovative EVOM technology, qualitatively measuring cell monolayer health and quantitatively measuring cell confluence by determining an increase or a plateau in tissue resistance.
The video below shows you how to stabilize the electrode array on the EVOM™ Auto:
VIDEO: How to Create a Plate File on the EVOM™ Auto
The EVOM™ Auto automates measurements of TEER in epithelial or endothelial monolayers cultured on high throughput screening 96-well plates utilizing our innovative EVOM™ technology, qualitatively measuring cell monolayer health and quantitatively measuring cell confluence by determining an increase or a plateau in tissue resistance.
VIDEO: How to Download and Delete a Data File on the EVOM™ Auto
The EVOM™ Auto automates measurements of TEER in epithelial or endothelial monolayers cultured on high throughput screening 96-well plates utilizing our innovative EVOM™ technology, qualitatively measuring cell monolayer health and quantitatively measuring cell confluence by determining an increase or a plateau in tissue resistance.
The video below shows you how to download and how to delete a data file EVOM™ Auto:
VIDEO: EVOM™ Auto, Introducing the Experiment Screen
The EVOM™ Auto automates measurements of TEER in epithelial or endothelial monolayers cultured on high throughput screening 96-well plates utilizing our innovative EVOM™ technology, qualitatively measuring cell monolayer health and quantitatively measuring cell confluence by determining an increase or a plateau in tissue resistance.
The video below shows details the features and functions of the Experiment window on the EVOM™ Auto:
VIDEO: Introducing the EVOM™ Auto Home Screen
The EVOM™ Auto automates measurements of TEER in epithelial or endothelial monolayers cultured on high throughput screening 96-well plates utilizing our innovative EVOM™ technology, qualitatively measuring cell monolayer health and quantitatively measuring cell confluence by determining an increase or a plateau in tissue resistance.
The video below shows you the features of the homepage on the EVOM™ Auto:
VIDEO: How to Set up the EVOM Auto TEER Measurement System
Have you got the new EVOM Auto TEER Measurement System for 96-well HTS plates? This short videos shows how easy it is to setup.
VIDEO: Unboxing the EVOM™ Manual TEER meter
EVOM™ Manual is WPI's newest instrument to measure Trans Epithelial Electrical Resistance (TEER). Let's look at what comes with the system and how easy it is to setup.
VIDEO: How to Take Voltage Measurements with the EVOM™ Manual
EVOM™ Manual is WPI’s newest instrument to measure Trans Epithelial Electrical Resistance (TEER). Let’s look at how to set it up and take voltage measurements.
VIDEO: 9 Reasons to Trust the EVOM™ Manual TEER Measurement Meter
WPI’s EVOM™ technology is the gold standard for delivering stable and repeatable Trans Epithelial Electrical Resistance (TEER) measurements. Here are nine reasons to trust the new EVOM Manual TEER Meter for qualitatively measuring cell monolayer health and quantitatively measuring cell confluence.
VIDEO: How to Take Resistance Measurements with EVOM™ Manual
EVOM™ Manual is WPI’s newest instrument to measure Trans Epithelial Electrical Resistance (TEER). Let’s look at how to set it up and take resistance measurements.
VIDEO: Which EVOM™ Electrode is Right for Your Application?
WPI’s EVOM™ Manual is the gold standard for delivering stable and repeatable Trans Epithelial Electrical Resistance (TEER) measurements. The EVOM™ Manual is the newest TEER meter. It qualitatively measures cell monolayer health and quantitatively measures cell confluence by determining an increase or a plateau in tissue resistance detected using our innovative EVOM™ technology. WPI’s state of the art EVOM™ technology provides you with real-time, valuable feedback during experimental measurements.
VIDEO: How to Replace the STX4 Electrode Blades
The new STX4 electrode works with the EVOM3, and the blades are replaceable. EVOM3 is used for making TEER (TER) Measurements in cell culture plates. Here's a quick tutorial to show you how to replace the blades.
VIDEO: 7 Reasons to Love the New EVOM3 for TEER Measurement
The NEW EVOM3 Epithelial Volt/Ohm Meter delivers improved workflow efficiency, increased stability and more repeatable measurements than traditional Trans Epithelial Electrical Resistance (TEER) meters. Here are seven things you will love about the new EVOM3.
How to Set the Gap on your WPI EndOhm Chambers
WPI EndOhm chambers are used with WPI's EVOM2 meter for making TEER (transepithelial electrical resistance) measurements. Each EndOhm chamber comes with a "spacer" disk for calibrating the gap between the two chamber electrodes. A consistent gap ensures reliable measurements. Here Subhra shows how to calibrate your chambers.
Resurfacing Electrodes in a WPI EndOhm Chamber
WPI EndOhm chambers are used with WPI's EVOM2 meter for making TEER (transepithelial electrical resistance) measurements. After heavy use your background resistance measurement may start to rise. Your electrodes may need to be resurfaced to remove buildup of proteins, sugars and biological materials. Here Subhra demonstrates how to clean and resurface your EndOhm chambers.
Choosing an EndOhm Chamber Compatible with your Cell Culture Inserts
WPI's EndOhm chambers are used with WPI's EVOM2 meter to measure TEER (transepithelial electrical resistance) in cell culture inserts. Three chamber sizes are available for 6-well plates, 12-well plates and 24-well plates. Here Subhra demonstrates how to choose an EndOhm chamber to match the cell culture inserts you are using.
EVOM2-How to Equilibrate Your STX2
The World Precision Instruments (WPI) EVOM2 is used for making trans epithelial electrical resistance (or TEER) measurements. Two silver/silver chloride pellets are used for the electrodes. The chloride ion tends to migrate, which is a reversible reaction. But, because of this chloride ion swapping, the electrodes need to be polarized before each use. Before using the meter for making voltage measurements, equilibrate the electrodes. This video shows you how.