A Microprobe Thermometer is the instrument of choice for biological and laboratory temperature measurements. These thermometers are very versatile, providing fast response, high accuracy and stability with digital display and analog signal for connection to a computer or recorder. With the wide selection of probes, the instruments can be used in almost any application.
| Order code | Description | Image |
| BAT-10R/LOP | Multiple Input Type T Thermocouple Thermometer, rechargeable NiCad batteries and 110 VAC adapter (microprobes ordered separately) | ![]() |
| BAT-10R/LOP220 | Multiple Input Type T Thermocouple Thermometer, rechargeable NiCad batteries and 220 VAC adapter (microprobes ordered separately) | ![]() |
| BAT-12R | Single Input Type T Thermocouple Thermometer, rechargeable NiCad batteries and 110 VAC adapter (microprobes ordered separately) | ![]() |
| BAT-12R-220 | Single Input Type T Thermocouple Thermometer, rechargeable NiCad batteries and 220 VAC adapter (microprobes ordered separately) | ![]() |
 Â
Benefits
Applications
A Microprobe Thermometer is the instrument of choice for biological and laboratory temperature measurements. These thermometers are very versatile, providing fast response, high accuracy and stability with digital display and analog signal for connection to a computer or recorder. With the wide selection of probes, the instruments can be used in almost any application.
BAT-10Â This is the most versatile thermometer available. The instrument has a wide temperature range and fast response with most microprobes. The BATâ10 accuracy is NIST traceable and in each of the two temperature ranges, the accuracy is the same as the resolution. There are three microprobe inputs, 1 and 2 can be selected as separate inputs while 2 and 3 will read the differential temperature measurement between the two. The instrument has automatic warnings for low battery or faulty probes on the digital display. The linearized analog output (LOP) signal allows ease of connection to a data acquisition system or recorder.
BAT-12 This thermometer has a sealed construction making it water, dust and fume resistant. The BAT-12 has a single microprobe input and a single range with the same high accuracy as the BAT-10. Comes complete with carrying case.
The thermometers can be used with any âType Tâ thermocouple. Select a temperature microprobe on the following page for your specific application.
Systems include rechargeable NiCd batteries and 110 VAC adapter. (Microprobes must be ordered separately.)
| Â | BAT-10R/LOP BAT-10R/LOP220 |
BAT-12R BAT-12R-220 |
| TEMPERATURE RANGE & RESOLUTION | -200°C to +400ÂșC, 1ÂșC resolution -100°C to +199.9ÂșC, 0.1ÂșC resolution |
-100°C to +199.9ÂșC, 0.1ÂșC resolution |
| DIFFERENTIAL TEMPERATURE RANGE | -19.99°C to +19.99ÂșC Linearization centered at 40°C 0.01°C resolution |
N/A |
|
ACCURACY 1° Range |
|
 0.1°C ± 1 digit between 0-50°C |
| REPEATABILITY | ± 1 least significant digit |  |
| CALIBRATION CONFORMITY | Conforms to NIST tables | Follows NIST thermocouple tables within 1 digit |
| DISPLAY | 3œ Digit LCD | 3œ Digit LCD |
| INPUTâSOCKET | Â Miniature, quick disconnect, copper-constantan | Miniature, quick disconnect, copper-constantan |
| ANALOG OUTPUT | Non-linearized set at 1.6 V, corresponding to temperature of 401°C | â 10 mV per degree C |
| POWERâSUPPLY/BATTERIES | 4 Ni-Cad âCâ cells (rechargeable unit)Â | 9V Ni-Cad with charger |
| SENSORS | Three Type T thermocouple inputs | One Type T thermocouple input |
| AMBIENT OPERATING RANGE | 15-45°C | Auto-compensated to 0.1°C from 0°C to 50°C |
| Dimensions | 21.6 x 22.9 x 8.9âcm (8.5 x 9 x 3.5 in.) | 12.7 x 6.4 x 15.2âcm (5 x 2.5 x 6 in.) |
| WEIGHT | 1.6 kg (3.5 lb.), including carrying case | 1 kg (2 lb.), including carrying case |
Â
Â

$1,720.00