Cellix

WPI Europe partners with Cellix to provide microfluidic solutions with easy-to-use benchtop instruments and associated biochips for cell-based assays and particle studies including droplet generation assays.

Cellix range offers high-quality and effective microfluidic pumps, biochips, software and automated solutions for cell-based assays. Pairing with WPI’s fluidic knowledge enables us to remain at the forefront of the microfluidics industry and provide high-quality products and solutions, to guarantee consistent customer satisfaction.

Cellix Pumps,  Cellix Microfluidic Pumps 

Microfluidic Syringe Pumps

  • ExiGo Pump Series 

    ExiGo Pump series is a microfluidic syringe pump controlled by SmartFlo software that can be run from a PC. Up to 4 ExiGo pumps can be plugged together with independent programming of each pump's flow profile.

    • Flow rate 10 nL/min to 13 mL/min
    • Standard syringes from 100 µL to 5 mL - use the automatic refill with ExiGo Manifold accessory
    • Programmable flow profiles with any combination of constant, ramp, sine and step
    • Fast switching - response times as low as 50 ms
  • Mirus Evo Pump

    Mirus Evo Pump is an 8-channel pulse-free microfluidic syringe pump. Syringe pump comes with the MultiFlow8 providing equal flow rates in each of the 8 channels.

    • Flow rate: 100 nL/min - 10 mL/min
    • Standard syringes: 100 µL, 250 µL, 500 µL, 1 mL, 5 mL glass syringes
    • Programmable with PC-controlled VenaFluxAssay software
1 の 2

Microfluidic Pressure Pumps

  • UniGo Pump series

    UniGo Pump series is a microfluidic pressure pump controlled by SmartFlo software that can be run from a PC. Connect up to 4 UniGo pumps together with independent programming of each pump's flow profile.

    • Flow rate 1 nL/min to 1 mL/min
    • Programmable flow profiles with any combination of constant, ramp, sine and step
    • Input pressure up to 10 bar (145 psi) via external compressor or vacuum pump required
    • Closed loop feedback - flow sensors provide active feedback and precise flow control
  • 4U Pump series

    4U Pump series is a four channel pulse free microfluidic pressure pump controlled by SmartFlo software that can be run from a PC.

    • Flow rate: 1 µL/min - 1 mL/min
    • Programmable with PC-controlled VenaFluxAssay software
    • Input pressure up to 10 bar (145 psi) via external compressor or vacuum pump required
    • Closed loop feedback - flow sensors provide active feedback and precise flow control
1 の 2

Microfluidic Recirculating Pumps

Kima pump is a microfluidic recirculating pump designed to aid cell culture (e.g. endothelial cells) under physiological conditions (shear flow) in various biochips and flow chambers.

The Kima pump when used with the Vena8 Endothelial+ biochip offers 8 parallel microchannels and with additional Kima pumps the Kima controller can control and run up to 32 microchannels.

  • Flow rate ~250 µL/min to 600 µL/min.  If using Kima pump with Vena8 biochip range, the flow splitter will result in flow rates of ~30 - 75µL/min in each of the 8 channels of the biochip
  • Recirculating culture media saves reagents and no additional fluidic valves required
  • Incubator safe
  • Easy to use - control up to 4 pumps with same controller and iPod Touch

Cellix Biochips

Biochips For Cell Adhesion & Cell Culture Under Flow

1 の 3
  • Cellix Vena Delta Y1 Biochip

    The VenaDeltaY1 biochips contain branching microchannels for dual flow / dual injection of samples.  Ideal for studying chemotactic gradients, dual flow, multilaminar flow & diffusion.

    Each biochip contains 4 Y-shaped capillaries in parallel which can be coated with different adhesion molecules for cell receptor-ligand (i.e. cell-matrix interactions) studies under shear flow with dual-injection (chemotaxis experiments) or for investigation of thrombi formation at the Y-channel branch.

    • Branching Y-junction at input port
    • Mimic branching microvascular networks
    • Chemotaxis assays, dual flow, multilaminar flow & diffusion
    • Choice of channel size 400 µm (width) x 100 µm (depth) or 800 µm (width) x 120 µm (depth)

    Cellix Vena8 Delta Y BiochipTechnical Notes

    Product Code

    • V4DY1-400-100-1-1P10, VenaDeltaY1 Biochip Pack 10 (Minimum order of 6 packs) - channel size 400 µm (width) x 100 µm (depth)
    • V4DY1-800-120-1-1P10, VenaDeltaY1 Biochip Pack 10 (Minimum order of 6 packs) - channel size 800 µm (width) x 120 µm (depth)

  • Cellix Vena Delta Y2 Biochip

    The VenaDeltaY2 biochips contain branching microchannels for dual flow / dual injection of samples.  Ideal for studying chemotactic gradients, dual flow, multilaminar flow & diffusion.

    Each biochip contains 4 Y-shaped capillaries at both ends in parallel which can be coated with different adhesion molecules for cell receptor-ligand (i.e. cell-matrix interactions) studies under shear flow with dual-injection (chemotaxis experiments) or for investigation of thrombi formation at the Y-channel branch.

    • Branching Y-junction at input & exit ports
    • Mimic branching microvascular networks
    • Chemotaxis assays, dual flow, multilaminar flow & diffusion
    • Channel sizes:  600 µm (width) x 100 µm (depth)

    Cellix Vena8 Delta Y BiochipTechnical Notes 

    Product Code

    • V4DY2-600-100-2-1P10, VenaDeltaY2 Biochip Pack 10 (Minimum order of 6 packs)
  • Cellix Vena Delta T Biochip

    The VenaDeltaT biochip contains 4 T-junction shaped capillaries in parallel which can be coated with different adhesion molecules for cell receptor-ligand (i.e. cell-matrix interactions) studies under shear flow with dual-injection (chemotaxis experiments) or for investigation of thrombi formation at the T-channel branch.

    • 4 T-junction shaped capillaries
    • Channel sizes:  400 µm (width) x 100 µm (depth)

    Product Code

    • V4DT-400-100-1-1P10, VenaDeltaT Biochip Pack 10

    Cellix Vena Delta W Biochip

    The VenDeltaW biochip contains 2 W-junction shaped capillaries and 1 Y-junction shaped capillary in the centre which can be coated with different adhesion molecules for cell receptor-ligand (i.e. cell-matrix interactions) studies under shear flow with dual-injection (chemotaxis experiments) or for investigation of thrombi formation at the W or Y-channel branch.

    • 2 W-junction shaped capillaries
    • 1 Y-junction shaped capillary
    • Channel sizes:  400 µm (width) x 100 µm (depth)

    Product Code

    • VDW-400-100-1-1P10, VenaDeltaW Biochip Pack 10

1 の 3

Biochips For Transmigration: Vena T4

Chemotaxis, Transmigration, Invasion Assays, Organ-on-Chip, Culture on-chip.

Each biochip contains 4 capillaries in parallel with a membrane of pore size 2-10 um diameter separating them from a microwell underneath.  Chemoattractants can be placed inside the well for subsequent study of cell migration through the membrane under shear flow.

  • Under shear flow
  • Cell adhesion and transmigration under shear flow
  • Transmigration through microporous membrane into underlying microwell which may contain chemoattractant
  • Channel sizes:  400 µm (width) x 100 µm (depth)
  • Pores sizes:  choice of 2 µm; 5 µm; 8 µm or 10 µm

VenaT4 Biochip Technical Notes

VenaT4 Biochip Protocol Notes

 Product Code

  • VT4-400-100-2-1P10, VenaT4 Biochip Pack 10

Biochips For Droplet Generation & Microfluidic Studies

  •  DropChip 

    • Droplet Generation
    • Under shear flow
    • 3 Droplet Generators & 1 splitter
    • High-throughput generation of microdroplets and monodispersed oils/emulsions

    DropChips are fabricated from plastic (acrylic) and have a footprint of 40 mm x 50 mm (W x L).  Each DropChip contains:??

    • 1 x Flow Splitter and
    • 3 x Droplet Generator junctions:2 x Flow-Focusing junctions, single-injection dispersed phase1 x Flow Focusing junction with dual-injection dispersed phase
  • Cellix Vena Delta Y1 Biochip

    The VenaDeltaY1 biochips contain branching microchannels for dual flow / dual injection of samples.  Ideal for studying chemotactic gradients, dual flow, multilaminar flow & diffusion.

    Each biochip contains 4 Y-shaped capillaries in parallel which can be coated with different adhesion molecules for cell receptor-ligand (i.e. cell-matrix interactions) studies under shear flow with dual-injection (chemotaxis experiments) or for investigation of thrombi formation at the Y-channel branch.

    • Branching Y-junction at input port
    • Mimic branching microvascular networks
    • Chemotaxis assays, dual flow, multilaminar flow & diffusion
    • Choice of channel size 400 µm (width) x 100 µm (depth) or 800 µm (width) x 120 µm (depth)

    Cellix Vena8 Delta Y BiochipTechnical Notes

    Product Code

    • V4DY1-400-100-1-1P10, VenaDeltaY1 Biochip Pack 10 (Minimum order of 6 packs) - channel size 400 µm (width) x 100 µm (depth)
    • V4DY1-800-120-1-1P10, VenaDeltaY1 Biochip Pack 10 (Minimum order of 6 packs) - channel size 800 µm (width) x 120 µm (depth)

     

  • Cellix Vena Delta Y2 Biochip

    The VenaDeltaY2 biochips contain branching microchannels for dual flow / dual injection of samples.  Ideal for studying chemotactic gradients, dual flow, multilaminar flow & diffusion.

    Each biochip contains 4 Y-shaped capillaries at both ends in parallel which can be coated with different adhesion molecules for cell receptor-ligand (i.e. cell-matrix interactions) studies under shear flow with dual-injection (chemotaxis experiments) or for investigation of thrombi formation at the Y-channel branch.

    • Branching Y-junction at input & exit ports
    • Mimic branching microvascular networks
    • Chemotaxis assays, dual flow, multilaminar flow & diffusion
    • Channel sizes:  600 µm (width) x 100 µm (depth)

     Cellix Vena8 Delta Y BiochipTechnical Notes

     

    Product CodeProduct DescriptionV4DY2-600-100-2-1P10VenaDeltaY2 Biochip Pack 10 (Minimum order of 6 packs)

     

1 の 3

Product list

  • 商品名の例

    通常価格 $19.99
    セール価格 $19.99 通常価格
  • 商品名の例

    通常価格 $19.99
    セール価格 $19.99 通常価格
  • 商品名の例

    通常価格 $19.99
    セール価格 $19.99 通常価格
  • 商品名の例

    通常価格 $19.99
    セール価格 $19.99 通常価格
1 の 4