Key features:
| SKU | Options | Description |
|---|---|---|
| AL-DUAL-AL-1000 | Standard, AL-1000 | Dual Aladdin system of two AL-1000 programmable syringe pumps with a sync cable, for continuous flow, emulsification or independent use. |
| AL-DUAL-AL-1000X | Continuous, AL-1000X | Continuous Aladdin system of two AL-1000X advanced syringe pumps with a sync cable that removes the flow pauses of push-pull systems. |
| AL-DUAL-AL-1010 | High Pressure, AL-1010 | Dual Aladdin system of two AL-1010 high-pressure syringe pumps with a sync cable, for continuous flow, emulsification or independent use. |
| AL-DUAL-AL-1010X | Continuous, AL-1010X | Continuous Aladdin system of two AL-1010X high-pressure advanced syringe pumps with a sync cable for flow without push-pull pauses. |
AL-DUAL-AL-1000 – Standard, AL-1000
A dual Aladdin pump system made of two AL-1000 programmable single-channel syringe pumps linked by a synchronization cable. The pumps can run together for continuous push-pull flow or emulsification, or independently.
Includes:
Key features:
Push-pull continuous flow needs the optional P-DKIT check valve set, sold separately.
AL-DUAL-AL-1000X – Continuous, AL-1000X
A continuous Aladdin pump system made of two AL-1000X advanced programmable syringe pumps linked by a synchronization cable. The refilling pump refills faster than the other pump infuses, then primes or overlaps the infusion, so flow continues without the pauses and drop-offs of push-pull systems. The pumps can also run for emulsification or independently.
Includes:
Key features:
Continuous push-pull flow needs the optional P-DKIT check valve set, sold separately.
AL-DUAL-AL-1010 – High Pressure, AL-1010
A dual Aladdin high-pressure pump system made of two AL-1010 SyringeONE 100 programmable syringe pumps linked by a synchronization cable. The pumps can run together for continuous push-pull flow or emulsification, or independently.
Includes:
Key features:
Push-pull continuous flow needs the optional P-DKIT check valve set, sold separately.
AL-DUAL-AL-1010X – Continuous, AL-1010X
A continuous Aladdin pump system made of two AL-1010X advanced high-pressure programmable syringe pumps linked by a synchronization cable. The refilling pump refills faster than the other pump infuses, then primes or overlaps the infusion, so flow continues without the pauses and drop-offs of push-pull systems. The pumps can also run for emulsification or independently.
Includes:
Key features:
Continuous push-pull flow needs the optional P-DKIT check valve set, sold separately.
| SYRINGE SIZES | 1-60 mL, or 0.5-5µL micro syringes |
| NUMBER OF SYRINGES | 1 |
| MOTOR TYPE | Step Motor, 1/8 to 1/2 step modes |
| STEPS PER REVOLUTIONS | 400 |
| STEPPING (max. min.) | 0.21µm to 0.850µm |
| MOTOR TO DRIVE SCREW RATIO | 15/28 |
| SPEED (max./min.) | 5.1 cm/min / 0.0042 cm/hr |
| PUMPING RATES | 1699 mL/hr with 60 mL syringe, to 0.73µL/hr with 1 mL syringe |
| MAXIMUM FORCE | 35 lb at min. speed, 18 lb at max. speed |
| NUMBER OF PROGRAM PHASES | 41 |
| RS-232 PUMP NETWORK | 100 pumps maximum |
| POWER supply | Wall adapter 12V DC @ 850 mA |
| DIMENSIONS | 22.9 x 14.6 x 11.4 cm (8.75 x 5.75 x 4.5 in.) |
| WEIGHT | 3.2 kg |
| SYRINGE SIZES | 1-60 mL, or 0.5-5µL micro syringes |
| NUMBER OF SYRINGES | 1 |
| MOTOR TYPE | Step Motor, 1/8 to 1/2 step modes |
| STEPS PER REVOLUTIONS | 400 |
| STEPPING (max. min.) | 0.21µm to 0.850µm |
| MOTOR TO DRIVE SCREW RATIO | 15/28 |
| SPEED (max./min.) | 5.1 cm/min / 0.0042 cm/hr |
| PUMPING RATES | 1699 mL/hr with 60 mL syringe, to 0.73µL/hr with 1 mL syringe |
| MAXIMUM FORCE | 35 lb at min. speed, 18 lb at max. speed |
| NUMBER OF PROGRAM PHASES | 41 |
| RS-232 PUMP NETWORK | 100 pumps maximum |
| POWER supply | Wall adapter 12V DC @ 850 mA |
| DIMENSIONS | 22.9 x 14.6 x 11.4 cm (8.75 x 5.75 x 4.5 in.) |
| WEIGHT | 3.2 kg |
| SYRINGE SIZES | 1-60 mL (140 mL partially filled) |
| NUMBER OF SYRINGES | 1 |
| MOTOR TYPE | Step Motor, 1/8 to 1/2 step modes |
| STEPS PER REVOLUTIONS | 200 |
| STEPPING (min. max.) | 0.425 µm (1/8 stepping) to 1.701 µm (1/2 stepping) |
| MOTOR TO DRIVE SCREW RATIO | 15/28 |
| SPEED (max./min.) | 18.4 cm/min / 0.0084 cm/hr |
| PUMPING RATES | 6120 mL/hr with 60mL syringe, to 1.459 µL/hr with 1mL syringe |
| MAXIMUM FORCE | 100 lb at min. speed, 18 lb at max. speed |
| NUMBER OF PROGRAM PHASES | 41 |
| RS-232 PUMP NETWORK | 100 pumps maximum |
| POWER supply | Wall adapter 12V DC @ 1000mA |
| DIMENSIONS | 22.9 x 14.6 x 11.4 cm (8.75 x 5.75 x 4.5 in.) |
| WEIGHT | 1.6 kg (3.6 lb) |
| SYRINGE SIZES | 1-60 mL (140 mL partially filled) |
| NUMBER OF SYRINGES | 1 |
| MOTOR TYPE | Step Motor, 1/8 to 1/2 step modes |
| STEPS PER REVOLUTIONS | 200 |
| STEPPING (min. max.) | 0.425 µm (1/8 stepping) to 1.701 µm (1/2 stepping) |
| MOTOR TO DRIVE SCREW RATIO | 15/28 |
| SPEED (max./min.) | 18.4 cm/min / 0.0084 cm/hr |
| PUMPING RATES | 6120 mL/hr with 60mL syringe, to 1.459 µL/hr with 1mL syringe |
| MAXIMUM FORCE | 100 lb at min. speed, 18 lb at max. speed |
| NUMBER OF PROGRAM PHASES | 41 |
| RS-232 PUMP NETWORK | 100 pumps maximum |
| POWER supply | Wall adapter 12V DC @ 1000mA |
| DIMENSIONS | 22.9 x 14.6 x 11.4 cm (8.75 x 5.75 x 4.5 in.) |
| WEIGHT | 1.6 kg (3.6 lb) |
Birngruber, T., & Ghosh, A. (2013). Cerebral open flow microperfusion: A new in vivo technique for continuous measurement of substance transport across the intact blood–brain barrier. Clinical and …. Retrieved from https://onlinelibrary.wiley.com/doi/10.1111/1440-1681.12174/full
Ferreira, D., Reis, R., & Azevedo, H. (2013). Peptide-based microcapsules obtained by self-assembly and microfluidics as controlled environments for cell culture. Soft Matter. Retrieved from https://pubs.rsc.org/EN/content/articlehtml/2013/sm/c3sm51189h
Herricks, T., Avril, M., Janes, J., Smith, J., & Rathod, P. (2013). Clonal Variants of Plasmodium falciparum Exhibit a Narrow Range of Rolling Velocities to Host Receptor CD36 under Dynamic Flow Conditions. Eukaryotic cell. Retrieved from https://ec.asm.org/content/12/11/1490.short
Maya, H., Vincent, M., & Nötzli, S. (2013). Increased porosity of electrospun hybrid scaffolds improved bladder tissue regeneration. … Research Part A. Retrieved from https://onlinelibrary.wiley.com/doi/10.1002/jbm.a.34889/full
Tõnurist, K., Thomberg, T., & Jänes, A. (2013). Polymorphic Behavior and Morphology of Electrospun Poly (Vinylidene Fluoride) Separator Materials for Non-Aqueous Electrolyte Based Electric Double Layer. ECS …. Retrieved from https://ecst.ecsdl.org/content/50/45/49.short
Tõnurist, K., Thomberg, T., Jänes, A., & Lust, E. (2013). Specific Performance of Electrical Double–Layer Capacitors Based on Different Separator Materials and Non–Aqueous Electrolytes. ECS Transactions. Retrieved from https://ecst.ecsdl.org/content/50/43/181.short
Zander, N., & Orlicki, J. (2013). Electrospun polycaprolactone scaffolds with tailored porosity using two approaches for enhanced cellular infiltration. Journal of Materials …. Retrieved from https://link.springer.com/article/10.1007/s10856-012-4771-7
Zhang, J., Jiang, D., & Peng, H. (2014). A pressurized filtration technique for fabricating carbon nanotube buckypaper: Structure, mechanical and conductive properties. Microporous and Mesoporous Materials. Retrieved from https://www.sciencedirect.com/science/article/pii/S1387181113005192
Zhang, J., Jiang, D., Peng, H., & Qin, F. (2013). Enhanced mechanical and electrical properties of carbon nanotube buckypaper by in situ cross-linking. Carbon. Retrieved from https://www.sciencedirect.com/science/article/pii/S000862231300568X

$1,771.00
Múltiples SKUs
¡Se está vendiendo rápido!
Consigue el tuyo mientras puedas.