Key features:

  • Each pump accepts 1 to 60 ml syringes or 0.5 to 5 µl microsyringes
  • Motor stall detection
SKU Options Description
AL-DUAL-AL-1000 Standard, AL-1000 Dual Aladdin system of two AL-1000 programmable syringe pumps with a sync cable, for continuous flow, emulsification or independent use.
AL-DUAL-AL-1000X Continuous, AL-1000X Continuous Aladdin system of two AL-1000X advanced syringe pumps with a sync cable that removes the flow pauses of push-pull systems.
AL-DUAL-AL-1010 High Pressure, AL-1010 Dual Aladdin system of two AL-1010 high-pressure syringe pumps with a sync cable, for continuous flow, emulsification or independent use.
AL-DUAL-AL-1010X Continuous, AL-1010X Continuous Aladdin system of two AL-1010X high-pressure advanced syringe pumps with a sync cable for flow without push-pull pauses.

Details by version

AL-DUAL-AL-1000 – Standard, AL-1000

A dual Aladdin pump system made of two AL-1000 programmable single-channel syringe pumps linked by a synchronization cable. The pumps can run together for continuous push-pull flow or emulsification, or independently.

Includes:

  • 2 x AL-1000 syringe pumps
  • Synchronization cable for reciprocating use

Key features:

  • Each pump: flow 0.001 µl/hr (0.5 µl syringe) to 3470 ml/hr (140 ml syringe); dispensing accuracy ±1%
  • Each pump: linear force 35 lb at low speed; 18 lb at maximum speed
  • Displays total volume dispensed in ml or µl; rate can be changed while pumping
  • Up to 41 pumping phases; program via keypad or computer
  • Network, control and monitor up to 100 pumps from one computer

Push-pull continuous flow needs the optional P-DKIT check valve set, sold separately.

AL-DUAL-AL-1000X – Continuous, AL-1000X

A continuous Aladdin pump system made of two AL-1000X advanced programmable syringe pumps linked by a synchronization cable. The refilling pump refills faster than the other pump infuses, then primes or overlaps the infusion, so flow continues without the pauses and drop-offs of push-pull systems. The pumps can also run for emulsification or independently.

Includes:

  • 2 x AL-1000X syringe pumps
  • Synchronization cable

Key features:

  • Transition between syringes tuned by infusion rate, refill rate, priming rate, prime volume and overlap volume
  • Gradient ramping of flow rates
  • Each pump: flow 0.001 µl/hr (0.5 µl syringe) to 3470 ml/hr (140 ml syringe); dispensing accuracy ±1%
  • Each pump: linear force 35 lb at low speed; 18 lb at maximum speed
  • Up to 41 pumping phases; program via keypad or computer; network up to 100 pumps

Continuous push-pull flow needs the optional P-DKIT check valve set, sold separately.

AL-DUAL-AL-1010 – High Pressure, AL-1010

A dual Aladdin high-pressure pump system made of two AL-1010 SyringeONE 100 programmable syringe pumps linked by a synchronization cable. The pumps can run together for continuous push-pull flow or emulsification, or independently.

Includes:

  • 2 x AL-1010 high-pressure syringe pumps
  • Synchronization cable for reciprocating use

Key features:

  • Each pump: linear force 100 lb at low speed; 18 lb at maximum speed
  • Each pump: flow 0.001 µl/hr (0.5 µl syringe) to 208.3 ml/min (140 ml syringe); dispensing accuracy ±1%
  • Displays total volume dispensed in ml or µl; rate can be changed while pumping
  • Up to 41 pumping phases; program via keypad or computer
  • Network, control and monitor up to 100 pumps from one computer

Push-pull continuous flow needs the optional P-DKIT check valve set, sold separately.

AL-DUAL-AL-1010X – Continuous, AL-1010X

A continuous Aladdin pump system made of two AL-1010X advanced high-pressure programmable syringe pumps linked by a synchronization cable. The refilling pump refills faster than the other pump infuses, then primes or overlaps the infusion, so flow continues without the pauses and drop-offs of push-pull systems. The pumps can also run for emulsification or independently.

Includes:

  • 2 x AL-1010X syringe pumps
  • Synchronization cable

Key features:

  • Transition between syringes tuned by infusion rate, refill rate, priming rate, prime volume and overlap volume
  • Gradient ramping of flow rates
  • Each pump: linear force 100 lb at low speed; 18 lb at maximum speed
  • Each pump: flow 0.001 µl/hr (0.5 µl syringe) to 208.3 ml/min (140 ml syringe)
  • Up to 41 pumping phases; program via keypad or computer; network up to 100 pumps

Continuous push-pull flow needs the optional P-DKIT check valve set, sold separately.

Ressourcen

Spezifikationen

SYRINGE SIZES 1-60 mL, or 0.5-5µL micro syringes
NUMBER OF SYRINGES 1
MOTOR TYPE  Step Motor, 1/8 to 1/2 step modes
STEPS PER REVOLUTIONS 400
STEPPING (max. min.) 0.21µm to 0.850µm
MOTOR TO DRIVE SCREW RATIO 15/28
SPEED (max./min.) 5.1 cm/min / 0.0042 cm/hr
PUMPING RATES 1699 mL/hr with 60 mL syringe, to 0.73µL/hr with 1 mL syringe
MAXIMUM FORCE 35 lb at min. speed, 18 lb at max. speed
NUMBER OF PROGRAM PHASES 41
RS-232 PUMP NETWORK 100 pumps maximum
POWER supply Wall adapter 12V DC @ 850 mA
DIMENSIONS 22.9 x 14.6 x 11.4 cm (8.75 x 5.75 x 4.5 in.)
WEIGHT 3.2 kg

AL-1000X Aladdin Syringe Pump

SYRINGE SIZES 1-60 mL, or 0.5-5µL micro syringes
NUMBER OF SYRINGES 1
MOTOR TYPE  Step Motor, 1/8 to 1/2 step modes
STEPS PER REVOLUTIONS 400
STEPPING (max. min.) 0.21µm to 0.850µm
MOTOR TO DRIVE SCREW RATIO 15/28
SPEED (max./min.) 5.1 cm/min / 0.0042 cm/hr
PUMPING RATES 1699 mL/hr with 60 mL syringe, to 0.73µL/hr with 1 mL syringe
MAXIMUM FORCE 35 lb at min. speed, 18 lb at max. speed
NUMBER OF PROGRAM PHASES 41
RS-232 PUMP NETWORK 100 pumps maximum
POWER supply Wall adapter 12V DC @ 850 mA
DIMENSIONS 22.9 x 14.6 x 11.4 cm (8.75 x 5.75 x 4.5 in.)
WEIGHT 3.2 kg
SYRINGE SIZES 1-60 mL (140 mL partially filled)
NUMBER OF SYRINGES 1
MOTOR TYPE Step Motor, 1/8 to 1/2 step modes
STEPS PER REVOLUTIONS 200
STEPPING (min. max.) 0.425 µm (1/8 stepping) to 1.701 µm (1/2 stepping)
MOTOR TO DRIVE SCREW RATIO 15/28
SPEED (max./min.) 18.4 cm/min / 0.0084 cm/hr
PUMPING RATES 6120 mL/hr with 60mL syringe, to 1.459 µL/hr with 1mL syringe
MAXIMUM FORCE 100 lb at min. speed, 18 lb at max. speed
NUMBER OF PROGRAM PHASES 41
RS-232 PUMP NETWORK 100 pumps maximum
POWER supply Wall adapter 12V DC @ 1000mA
DIMENSIONS 22.9 x 14.6 x 11.4 cm (8.75 x 5.75 x 4.5 in.)
WEIGHT 1.6 kg (3.6 lb)

AL-1010X Aladdin Syringe Pump

SYRINGE SIZES 1-60 mL (140 mL partially filled)
NUMBER OF SYRINGES 1
MOTOR TYPE Step Motor, 1/8 to 1/2 step modes
STEPS PER REVOLUTIONS 200
STEPPING (min. max.) 0.425 µm (1/8 stepping) to 1.701 µm (1/2 stepping)
MOTOR TO DRIVE SCREW RATIO 15/28
SPEED (max./min.) 18.4 cm/min / 0.0084 cm/hr
PUMPING RATES 6120 mL/hr with 60mL syringe, to 1.459 µL/hr with 1mL syringe
MAXIMUM FORCE 100 lb at min. speed, 18 lb at max. speed
NUMBER OF PROGRAM PHASES 41
RS-232 PUMP NETWORK 100 pumps maximum
POWER supply Wall adapter 12V DC @ 1000mA
DIMENSIONS 22.9 x 14.6 x 11.4 cm (8.75 x 5.75 x 4.5 in.)
WEIGHT 1.6 kg (3.6 lb)

Literaturverzeichnis

Birngruber, T., & Ghosh, A. (2013). Cerebral open flow microperfusion: A new in vivo technique for continuous measurement of substance transport across the intact blood–brain barrier. Clinical and  …. Retrieved from https://onlinelibrary.wiley.com/doi/10.1111/1440-1681.12174/full

Ferreira, D., Reis, R., & Azevedo, H. (2013). Peptide-based microcapsules obtained by self-assembly and microfluidics as controlled environments for cell culture. Soft Matter. Retrieved from https://pubs.rsc.org/EN/content/articlehtml/2013/sm/c3sm51189h

Herricks, T., Avril, M., Janes, J., Smith, J., & Rathod, P. (2013). Clonal Variants of Plasmodium falciparum Exhibit a Narrow Range of Rolling Velocities to Host Receptor CD36 under Dynamic Flow Conditions. Eukaryotic cell. Retrieved from https://ec.asm.org/content/12/11/1490.short

Maya, H., Vincent, M., & Nötzli, S. (2013). Increased porosity of electrospun hybrid scaffolds improved bladder tissue regeneration. …  Research Part A. Retrieved from https://onlinelibrary.wiley.com/doi/10.1002/jbm.a.34889/full

Tõnurist, K., Thomberg, T., & Jänes, A. (2013). Polymorphic Behavior and Morphology of Electrospun Poly (Vinylidene Fluoride) Separator Materials for Non-Aqueous Electrolyte Based Electric Double Layer. ECS  …. Retrieved from https://ecst.ecsdl.org/content/50/45/49.short

Tõnurist, K., Thomberg, T., Jänes, A., & Lust, E. (2013). Specific Performance of Electrical Double–Layer Capacitors Based on Different Separator Materials and Non–Aqueous Electrolytes. ECS Transactions. Retrieved from https://ecst.ecsdl.org/content/50/43/181.short

Zander, N., & Orlicki, J. (2013). Electrospun polycaprolactone scaffolds with tailored porosity using two approaches for enhanced cellular infiltration. Journal of Materials  …. Retrieved from https://link.springer.com/article/10.1007/s10856-012-4771-7

Zhang, J., Jiang, D., & Peng, H. (2014). A pressurized filtration technique for fabricating carbon nanotube buckypaper: Structure, mechanical and conductive properties. Microporous and Mesoporous Materials. Retrieved from https://www.sciencedirect.com/science/article/pii/S1387181113005192

Zhang, J., Jiang, D., Peng, H., & Qin, F. (2013). Enhanced mechanical and electrical properties of carbon nanotube buckypaper by in situ cross-linking. Carbon. Retrieved from https://www.sciencedirect.com/science/article/pii/S000862231300568X


Dual Aladdin Syringe Pump System

$1,771.00

Verwandte Produkte

1 von 1