{"title":"Bipolar Tungsten","description":"\u003carticle\u003e\n\u003csection class=\"article-content clearfix\"\u003e\n\u003cp\u003e\u003cstrong\u003eTungsten\u003c\/strong\u003e is a versatile and widely-used microelectrode material that offers a good balance between performance and cost.\u003c\/p\u003e\n\u003cdiv class=\"su-spacer sus5ef60b23aab66\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003ch3 class=\"module-title\"\u003eAdvantages\u003c\/h3\u003e\n\u003cdiv id=\"sul_5ef60b23aac04\" class=\"su-list su-list-style-default\"\u003e\n\u003cul\u003e\n\u003cli\u003eExtremely strong and stiff metal provides probes with exceptional rigidity.\u003c\/li\u003e\n\u003cli\u003eGreat for acute and chronic recording due to biocompatibility and lower cost.\u003c\/li\u003e\n\u003cli\u003eHigh corrosion resistance offers consistent long-term performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003ch3 class=\"module-title\"\u003eDisadvantages\u003c\/h3\u003e\n\u003cdiv id=\"sul_5ef60b23aac47\" class=\"su-list su-list-style-default\"\u003e\n\u003cul\u003e\n\u003cli\u003eDoes not provide the same degree of electrochemical performance or stability as platinum-iridium alloy, making it a poor alternative for microstimulation.\u003c\/li\u003e\n\u003cli\u003eLower charge transfer capacity of tungsten will result in larger, potentially unsafe interfacial potentials when applying the same stimulation current as to a platinum-iridium electrode.\u003c\/li\u003e\n\u003cli\u003eCertain pH or stimulation conditions can lead to tungsten corrosion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n\u003cdiv class=\"row flex\"\u003e\n\u003cdiv class=\"col-sm-6 col-md-3 flex\"\u003e\n\u003cdiv class=\"card\"\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-6 col-md-3 flex\"\u003e\n\u003cdiv class=\"card\"\u003e\n\u003cdiv class=\"card-body\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cimg src=\"https:\/\/www.wpi-europe.com\/downloads\/content\/DipTipMini_DS.pdf\" alt=\"\"\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/tungsten-tip.png\" alt=\"\" width=\"243\" height=\"161\"\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/bipolar-stereotrodes\/bipolar---tungsten\/standard-tip-profile.aspx\"\u003e\u003cstrong\u003eA - STANDARD TIP PROFILE\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003eOur standard tip profile features a sharp yet robust point that offers versatile performance and an effective balance between penetration and durability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/blunted-tip.png\" alt=\"\" width=\"243\" height=\"161\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/bipolar-stereotrodes\/bipolar---tungsten\/blunted-tip.aspx\"\u003e\u003cstrong\u003eB - BLUNTED TIP PROFILE\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003eOur blunted electrodes are engineered to have a more rounded, bullet-shaped tip. For many applications the blunted tip can offer superior stimulation performance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/tapered-tip.png\" alt=\"\" width=\"243\" height=\"161\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/bipolar-stereotrodes\/bipolar---tungsten\/tapered-tip.aspx\"\u003e\u003cstrong\u003eH - HEAT TREATED TAPERED TIP PROFILE\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003eOur heat-treated electrodes are intended for those investigators who must penetrate their probes through tough membranes, such as the dura mater of larger mammals.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/extra-fine-tip.png\" alt=\"\" width=\"243\" height=\"161\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/bipolar-stereotrodes\/bipolar---tungsten\/extra-fine-tip.aspx\"\u003e\u003cstrong\u003eF - EXTRA FINE TIP PROFILE\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003eOur extra-fine tip profile features a significantly sharper taper as well as\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","products":[],"url":"https:\/\/wpiinc.com\/ja\/collections\/bipolar-tungsten.oembed","provider":"World Precision Instruments","version":"1.0","type":"link"}