{"product_id":"sys-705-ultra-quiet-intracellular-amplifier","title":"Amplificatore intracellulare ultra silenzioso","description":"\u003c!-- section:details --\u003e\n\u003cp\u003e\u003ca href=\"\/it\/blog\/post\/wpi-s-low-noise-amplifiers-outperform-cheap-imitations\"\u003eScopri cosa devi sapere prima di acquistare un amplificatore\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eCaratteristiche\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSchermatura di guardia pilotata\u003c\/li\u003e\n\u003cli\u003ePorta di test\u003c\/li\u003e\n\u003cli\u003ePorta di terra\u003c\/li\u003e\n\u003cli\u003ePortatile\u003c\/li\u003e\n\u003cli\u003eStadio di testa remoto\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eVantaggi\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eConveniente\u003c\/li\u003e\n\u003cli\u003eAlimentato a batteria\u003c\/li\u003e\n\u003cli\u003eCompensazione della capacità\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplicazioni\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMisurare i potenziali d'azione intracellulari\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectro 705\u003c\/strong\u003e include 1 unità ciascuno dei seguenti \u003ca href=\"\/it\/var-3786-microelectrode-holder-meh1sf\"\u003eportamicroelettrodi\u003c\/a\u003e : MEH1SF10, MEH1SF12, MEH1SF15 e MEH1SF20. Per l'elettrodo di riferimento si consiglia l'\u003ca href=\"\/it\/var-3316-reference-cells\"\u003eRC1T\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectro 705\u003c\/strong\u003e, un preamplificatore elettrometrico a batterie, a basso rumore e a banda larga, è progettato per la misurazione della tensione intracellulare. È possibile collegare due unità 705 per formare una coppia di elettrometri differenziali ad alta impedenza. Ogni strumento include una sonda attiva miniaturizzata placcata in oro, alla quale è possibile collegare un microelettrodo utilizzando il portamicroelettrodo WPI in dotazione.\u003c\/p\u003e\n\u003ch2\u003eStadio di testa remoto\u003c\/h2\u003e\n\u003cp\u003eFacile da montare su qualsiasi micromanipolatore, questa sonda compatta, che contiene il primo stadio di amplificazione, include un portamicroelettrodo che si collega direttamente all'ingresso della sonda.\u003c\/p\u003e\n\u003ch2\u003eAlimentazione a batteria\u003c\/h2\u003e\n\u003cp\u003eQuattro batterie alcaline da 9 V (incluse) alimentano \u003cstrong\u003eElectro 705\u003c\/strong\u003e per circa 500 ore, garantendo una fonte di alimentazione pulita e a basso rumore e rendendo \u003cstrong\u003eElectro 705\u003c\/strong\u003e l'amplificatore più silenzioso disponibile. È possibile testare facilmente le batterie premendo un pulsante.\u003c\/p\u003e\n\u003ch2\u003eCompensazione della capacità\u003c\/h2\u003e\n\u003cp\u003eCompensa la riduzione del tempo di salita causata dalla capacità dell'elettrodo. È possibile neutralizzare fino a 50 pF di capacità di shunt dell'elettrodo.\u003c\/p\u003e\n\u003ch2\u003eSchermatura di guardia pilotata\u003c\/h2\u003e\n\u003cp\u003eÈ possibile ridurre ulteriormente la capacità parassita posizionando la schermatura di guardia pilotata (inclusa) sul portaelettrIodo all'estremità di ingresso della sonda.\u003c\/p\u003e\n\u003ch2\u003eFunzioni di test\u003c\/h2\u003e\n\u003cp\u003eUn circuito di innesco genera un'oscillazione momentanea che facilita la penetrazione cellulare. \u003cstrong\u003eElecto 705\u003c\/strong\u003e fornisce una corrente di test dell'elettrodo di 1 nA. La resistenza dell'elettrodo viene monitorata all'uscita 1X sotto forma di tensione (1 mV\/M). La porta di test della sonda consente di verificare comodamente il rumore intrinseco e il guadagno dell'amplificatore, senza ingombranti collegamenti di test esterni. È inoltre possibile regolare facilmente la corrente di dispersione dello stadio di testa. Il controllo della posizione della linea di base aggiunge o sottrae fino a 300 mV all'uscita dello stadio di testa, consentendo di azzerare le tensioni artefatto, come i potenziali di giunzione liquida, prima della registrazione.\u003c\/p\u003e\n\u003ch2\u003eUscita differenziale\u003c\/h2\u003e\n\u003cp\u003eÈ possibile collegare in tandem due unità \u003cstrong\u003eElectro 705\u003c\/strong\u003e per creare un sistema di sonde con amplificatore differenziale opzionale.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/Electro705_IMs.pdf\" target=\"_self\"\u003eManuale di istruzioni Electro 705\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\u003c!-- section:specifications --\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedenza di ingresso\u003c\/td\u003e\n\u003ctd\u003e10\u003csup\u003e12\u003c\/sup\u003e Ω, shuntata da 1pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eImpedenza di uscita\u003c\/td\u003e\n\u003ctd\u003e100 Ω, entrambe le uscite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGuadagno\u003c\/td\u003e\n\u003ctd\u003eX1: ±0,1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eIntervallo della tensione di ingresso\u003c\/td\u003e\n\u003ctd\u003e±5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTempo di salita\u003c\/td\u003e\n\u003ctd\u003e15 µs, 10-90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eLivello di rumore\u003c\/td\u003e\n\u003ctd\u003e500 μV picco-picco*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompensazione della capacità d'ingresso\u003c\/td\u003e\n\u003ctd\u003e0-50 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eCorrente di perdita del gate\u003c\/td\u003e\n\u003ctd\u003e±10 pA, regolabile a zero\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest della resistenza dell'elettrodo\u003c\/td\u003e\n\u003ctd\u003e1 mV\/MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003ePosizionamento CC\u003c\/td\u003e\n\u003ctd\u003e±300 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReiezione di modo comune\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10\u003csup\u003e4\u003c\/sup\u003e (in modalità differenziale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eAlimentazione\u003c\/td\u003e\n\u003ctd\u003eQuattro batterie alcaline da 9 V, incluse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensioni\u003c\/td\u003e\n\u003ctd\u003e8,5 x 3,5 x 2,2 in. (22 x 9 x 6 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003ePeso di spedizione\u003c\/td\u003e\n\u003ctd\u003e5 lb. (2,3 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e\n\u003c!-- section:references --\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eWan, E., Kushner, J. S., Zakharov, S., Nui, X.-W., Chudasama, N., Kelly, C., … Marx, S. O. (2013). La riduzione della corrente dei canali BK nella muscolatura liscia vascolare è alla base della vasocostrizione indotta dall'insufficienza cardiaca nei topi. \u003ci\u003eFASEB Journal : Official Publication of the Federation of American Societies for Experimental Biology\u003c\/i\u003e, \u003ci\u003e27\u003c\/i\u003e(5), 1859–67. \u003ca href=\"http:\/\/doi.org\/10.1096\/fj.12-223511\"\u003ehttp:\/\/doi.org\/10.1096\/fj.12-223511\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eGokina, N. I., Bonev, A. D., Gokin, A. P., \u0026amp; Goloman, G. (2013). Ruolo della compromissione della segnalazione del Ca2+ nelle cellule endoteliali nella disfunzione vascolare uteroplacentare durante la gravidanza di ratti diabetici. \u003ci\u003eAmerican Journal of Physiology - Heart and Circulatory Physiology\u003c\/i\u003e, \u003ci\u003e304\u003c\/i\u003e(7).\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eThomas, R. C., \u0026amp; Bers, D. M. (2013). Come realizzare microelettrodi sensibili al calcio. \u003ci\u003eCold Spring Harbor Protocols\u003c\/i\u003e, \u003ci\u003e2013\u003c\/i\u003e(4), 370–3. \u003ca href=\"http:\/\/doi.org\/10.1101\/pdb.prot072850\"\u003ehttp:\/\/doi.org\/10.1101\/pdb.prot072850\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKinoshita, H., Matsuda, N., Iranami, H., Ogawa, K., Hatakeyama, N., Azma, T., … Yamazaki, M. (2012). Il pretrattamento con isoflurano preserva la funzione dei canali K+ sensibili all'adenosina trifosfato nell'arteria umana esposta allo stress ossidativo causato da livelli elevati di glucosio. \u003ci\u003eAnesthesia \u0026amp; Analgesia\u003c\/i\u003e, \u003ci\u003e115\u003c\/i\u003e(1), 54–61. \u003ca href=\"http:\/\/doi.org\/10.1213\/ANE.0b013e318254270d\"\u003ehttp:\/\/doi.org\/10.1213\/ANE.0b013e318254270d\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eHaba, M., Kinoshita, H., Matsuda, N., Azma, T., Hama-Tomioka, K., Hatakeyama, N., … Hatano, Y. (2009). Effetto benefico del propofol sulla funzione dei canali K+ sensibili all'adenosina trifosfato arteriosi compromessa dal trombossano. \u003ci\u003eAnesthesiology\u003c\/i\u003e, \u003ci\u003e111\u003c\/i\u003e(2), 279–286. \u003ca href=\"http:\/\/doi.org\/10.1097\/ALN.0b013e3181a918a0\"\u003ehttp:\/\/doi.org\/10.1097\/ALN.0b013e3181a918a0\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eZheng, J., \u0026amp; Pollack, G. H. (2006). Esclusione dei soluti e distribuzione del potenziale in prossimità di superfici idrofile. In \u003ci\u003eAcqua e la cellula\u003c\/i\u003e (pp. 165–174). Dordrecht: Springer Netherlands. \u003ca href=\"http:\/\/doi.org\/10.1007\/1-4020-4927-7_8\"\u003ehttp:\/\/doi.org\/10.1007\/1-4020-4927-7_8\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003ePeters, O., Back, T., Lindauer, U., Busch, C., Megow, D., Dreier, J., \u0026amp; Dirnagl, U. (1998). Aumento della formazione di specie reattive dell'ossigeno dopo occlusione permanente e reversibile dell'arteria cerebrale media nel ratto, \u003ci\u003e18\u003c\/i\u003e(2), 196–205. \u003ca href=\"http:\/\/doi.org\/10.1097\/00004647-199802000-00011\"\u003ehttp:\/\/doi.org\/10.1097\/00004647-199802000-00011\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266235797594,"sku":"SYS-705","price":2800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/705-front_5a2fdcee-735a-40d4-b3cb-7445abfd79b3.jpg?v=1766399540","url":"https:\/\/wpiinc.com\/it\/products\/sys-705-ultra-quiet-intracellular-amplifier","provider":"World Precision Instruments","version":"1.0","type":"link"}