{"product_id":"micro-epore-pinpoint-cell-penetrator","title":"Penetratore cellulare di precisione WPI MICRO-ePORE","description":"\u003c!-- section:details --\u003e\n\u003cdiv style=\"padding: 20px 0;\"\u003e\u003ca href=\"\/it\/pinpoint-cell-penetrator-for-microinjection\" target=\"_blank\" rel=\"noopener\"\u003e \u003cspan class=\"pdf-button\"\u003eRichiedi informazioni\u003c\/span\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003ch2\u003eCaratteristiche\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDisplay touchscreen con pannello resistivo, utilizzabile con i guanti\u003c\/li\u003e\n\u003cli\u003eControllo dell’iniezione tramite comando a pedale o manualmente dal touch screen \u003c\/li\u003e\n\u003cli\u003eInterfaccia utente intuitiva \u003c\/li\u003e\n\u003cli\u003eFrequenza e tensione regolabili dall’utente tramite touch screen \u003c\/li\u003e\n\u003cli\u003eIngombro ridotto \u003c\/li\u003e\n\u003cli\u003eQuattro protocolli programmabili dall’utente \u003c\/li\u003e\n\u003cli\u003eTono acustico di continuità regolabile per indicare l’iniezione attiva della sonda; contatore per indicare il numero totale di iniezioni \u003c\/li\u003e\n\u003cli\u003eUsa una tensione inferiore rispetto all’elettroporazione per attraversare un’area specifica della membrana cellulare\u003c\/li\u003e\n\u003cli\u003e\nSono disponibili \u003ca href=\"\/it\/var-300683-micro-epore-holder.html\"\u003esupporti per elettrodi con fili di platino\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eVantaggi\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAumenta la vitalità degli embrioni iniettati\u003c\/li\u003e\n\u003cli\u003eSistema flessibile\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eSi integra con PV820\/PV830 di WPI e con altri diffusi sistemi di microiniezione, come Femtojet® di Eppendorf e gli iniettori Narishige (Femtojet® 4I è un marchio registrato di Eppendorf.)\u003c\/li\u003e\n\u003cli\u003eMicroiniezione di diversi composti e biomolecole: DNA, RNA, proteine\u003c\/li\u003e\n\u003cli\u003ePrima e dopo l’impianto, in embrioni di diverse specie: topi, roditori, scimmie, bovini, suini, pesci zebra ecc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eMicroiniettore cellulare facile da usare - funzionamento a mani libere tramite comando a pedale \u003c\/li\u003e\n\u003cli\u003eFrequenza e tensione regolabili dall’utente - quattro protocolli programmabili\u003c\/li\u003e\n\u003cli\u003eUnità compatta e portatile che consente di risparmiare prezioso spazio sul banco di lavoro\u003c\/li\u003e\n\u003cli\u003eCompatibile con tutti i principali microscopi invertiti\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/it\/vir-micro-epore-ex1-micro-epore-extended-warranty\"\u003eGaranzia premium disponibile\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplicazioni principali\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMicroiniezione cellulare negli ovociti e negli embrioni di mammiferi in fase preimpianto, compresa la microiniezione di reagenti CRISPR-Cas9 nel citoplasma di embrioni allo stadio di due cellule \u003c\/li\u003e\n\u003cli\u003eMicroiniezione pronucleare di zigoti di roditori \u003c\/li\u003e\n\u003cli\u003eSilenziamento genico nel pesce zebra\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ciframe style=\"text-align: left;\" src=\"https:\/\/www.youtube.com\/embed\/S-mmNpNU0nc?rel=0\" width=\"510\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2\u003eUna soluzione semplice ed elegante\u003c\/h2\u003e\n\u003cp\u003eIl nuovo MICRO-ePORE™ Pinpoint Cell Penetrator di WPI è un sistema semplice e versatile, utilizzabile per eseguire in modo efficiente la microiniezione di un’ampia varietà di composti e biomolecole negli ovociti e negli embrioni di mammiferi in fase preimpianto. La tecnologia brevettata Flutter Electrode, in attesa di brevetto, favorisce una penetrazione della membrana precisa, pulita e circoscritta, senza lacerarla né danneggiarla, durante la microiniezione per la creazione di animali transgenici o la manipolazione cellulare.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/micro-epore-setup2_2d709440-c3f4-4fb1-930f-27ca4fa7f49c.jpg?v=1765950931\" alt=\"configurazione micro-epore\" width=\"75%\"\u003e\u003c\/p\u003e\n\u003ch2\u003ePinpoint Cell Penetrator a confronto con l’elettroporazione\u003c\/h2\u003e\n\u003cp\u003eL’elettroporazione usa un impulso elettrico in un mezzo per aprire pori nelle membrane cellulari delle cellule presenti nella cuvetta per elettroporazione, così da attraversare la membrana cellulare e introdurre materiale genetico.\u003c\/p\u003e\n\u003cp\u003eIl MICRO-ePORE™ Pinpoint Cell Penetrator di WPI offre diversi vantaggi rispetto all’elettroporazione tradizionale per la microiniezione cellulare. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIl nostro microiniettore cellulare di precisione usa una tensione molto più bassa per aprire un canale nella membrana cellulare.\u003c\/li\u003e\n\u003cli\u003eL’elettroporazione è un approccio a tappeto che apre numerosi pori nella membrana cellulare. Al contrario, il nostro microiniettore cellulare di precisione agisce su un’area specifica della membrana cellulare, proprio nel punto in cui avviene la microiniezione.\u003c\/li\u003e\n\u003cli\u003eLa sopravvivenza degli embrioni è significativamente maggiore con la penetrazione cellulare puntiforme rispetto all’elettroporazione.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDati sperimentali\u003c\/h2\u003e\n\u003cp\u003eI sistemi elettrofisiologici che utilizzano la capacità negativa sono stati regolarmente impiegati per la microiniezione cellulare di diverse biomolecole negli ovociti di mammifero, nonché in embrioni preimpianto e postimpianto negli studi di biologia dello sviluppo. Il sistema non più disponibile, l’amplificatore intracellulare WPI Cyto721, consente all’ago di perforare la membrana cellulare con un trauma fisico minimo. Più recentemente, questa tecnica è stata applicata al trasferimento genetico tramite microiniezione di reagenti CRISPR\/Cas9 in embrioni di topo allo stadio di due cellule. Gli autori hanno dimostrato che il loro metodo aumenta significativamente l’efficienza di knock-in e garantisce un’elevata vitalità degli embrioni.\u003c\/p\u003e\n\u003cp\u003eIl nuovo penetratore cellulare puntiforme MICRO-ePORE™ offre una soluzione esclusiva per la microiniezione cellulare, con conseguente elevata vitalità embrionale. Lo strumento genera un campo elettrico oscillante in un punto localizzato della membrana, immediatamente sotto il sito di iniezione. MICRO-ePORE™ crea piccoli pori reversibili nella membrana plasmatica, attraverso i quali viene microiniettato il materiale. Il ricercatore determina l’ampiezza e la frequenza del segnale più adatte all’applicazione. A differenza della microiniezione cellulare convenzionale, nella microiniezione mirata con MICRO-ePORE™ la membrana non si lacera, consentendo così una vitalità embrionale superiore. La tecnica è semplice ed elegante. Il nuovo prototipo di penetratore cellulare MICRO-ePORE™ è stato testato con successo su embrioni preimpianto di topo e primati, oltre che per il silenziamento genico nelle code di zebrafish.\u003c\/p\u003e\n\u003cp\u003eMICRO-ePORE™ è stato progettato per una serie di applicazioni, tra cui la generazione di topi knock-in CRISPR\/Cas9 con grandi inserzioni mediante microiniezione in embrioni allo stadio di due cellule, con un’elevata vitalità.7 MICRO-ePORE™ ha consentito la microiniezione precisa di oligomeri morfolino (knockdown antisenso) nelle code di zebrafish.\u003c\/p\u003e\n\u003ch2\u003eOpzione con elettrodo di riferimento a pozzetto\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/micro-epore-well-setup2_f1049e47-6ba2-4e39-be66-2f69e30a59e7.jpg?v=1765950937\" alt=\"Configurazione con l’elettrodo di riferimento a pozzetto\" width=\"50%\"\u003e\u003c\/p\u003e\n\u003ch2\u003eOpzione con elettrodo di riferimento a sonda\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/micro-epore-probe-setup_0f8fd091-29b7-4769-b5f0-ae41683ed370.jpg?v=1765950942\" alt=\"Configurazione con l’elettrodo di riferimento a pozzetto\" width=\"50%\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eQuesto mostra l’elettrodo di riferimento a sonda con un iniettore Eppendorf, di Fangtao Chi dell’UCLA\/MCDB e Utpal Banerjee.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/probe-style_f5fa11ae-9dc6-4d29-8ee2-797ca2871d4b.jpg?v=1765950948\" alt=\"Elettrodo di riferimento a sonda\" width=\"500\" height=\"383\"\u003e\u003c\/p\u003e\n\u003ch2\u003eConfigurazione del MICRO-ePORE™\u003c\/h2\u003e\n\u003cp\u003eIl nuovo penetratore cellulare puntiforme WPI MICRO-ePORE™ è un sistema semplice e versatile, utilizzabile per la microiniezione efficiente di un’ampia varietà di composti e biomolecole negli ovociti e negli embrioni di mammifero in fase preimpianto. La tecnologia brevettata Flutter Electrode, in attesa di brevetto, consente di penetrare la membrana in modo preciso, pulito e delicato, senza lacerarla né danneggiarla. Qui Gabe configura il sistema e collega tutti i componenti.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003c!-- section:resources --\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #00AFE9;\"\u003e\n\u003ctd\u003e\n\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMICRO-ePORE™ Versione 2\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ffffff;\"\u003eRev. 2 (per unità con numeri di serie a partire da 182508) \u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMICRO-ePORE™ Versione 1\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ffffff;\"\u003e Rev. 1 (per unità con numeri di serie fino a 182508) \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca title=\"User Manual for MICRO-ePORE\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/MICRO-ePORE_IMs.pdf\"\u003eManuale di istruzioni v2\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/MICRO-ePORE_QSG.pdf\"\u003eGuida rapida v2\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca title=\"User Manual for MICRO-ePORE\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/MICRO-ePORE_IMs_v1.pdf\"\u003eManuale di istruzioni v1\u003c\/a\u003e \u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/MICRO-ePORE_QSG_v1.pdf\"\u003eGuida rapida v1\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/MICRO-ePORE_BR.pdf\"\u003eMICRO-ePORE\u003csup\u003eTM\u003c\/sup\u003e Brochure\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/MICRO-ePORE_references.pdf\"\u003eÈ possibile ridurre la lisi degli embrioni usando MICRO-ePORE? W.Gardiner, J.Kenyon, T.Bell, S.Atkins\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eVideo\u003c\/h2\u003e\n\u003cp\u003eDisimballaggio del sistema MICRO-ePORE™\u003c\/p\u003e\n\u003cp\u003e \u003ciframe style=\"font-size: 12px;\" src=\"\/\/www.youtube.com\/embed\/GDj1ru6A0Iw?rel=0\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCollegamento del sistema MICRO-ePORE™\u003c\/p\u003e\n\u003cp\u003e\u003ciframe src=\"\/\/www.youtube.com\/embed\/Uhwx7-3Rd88?rel=0\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCollegamento dei portaeletrodi MICRO-ePORE™\u003c\/p\u003e\n\u003cp\u003e\u003ciframe style=\"font-size: 12px;\" src=\"\/\/www.youtube.com\/embed\/26qf0FtNcDI?rel=0\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\u003c!-- section:specifications --\u003e\n\u003ch2\u003eIl sistema include:\u003c\/h2\u003e\n\u003cp\u003e(1) Controller MICRO-ePORE™\u003cbr\u003e(1) Portaeletrodi con filo d'argento. A scelta tra:\u003cbr\u003e   • WPI #300863 Portaeletrodi WPI MICRO-ePORE\u003cbr\u003e   • WPI #300864 Portaeletrodi Femtojet® MICRO-ePORE\u003cbr\u003e   • WPI #300865 Narishige MICRO-ePORE™\u003cbr\u003e (1) Cavo di interfaccia del portamicroelettrodi \u003cbr\u003e(1) Elettrodo di riferimento a pozzetto \u003cbr\u003e(1) Gruppo elettrodo di riferimento a sonda \u003cbr\u003e(1) Interruttore a pedale 13142 \u003cbr\u003e(1) Cavo di alimentazione\u003cbr\u003e(1) Cavo di messa a terra 99789 MICRO-ePORE™\u003cbr\u003e(1) Manuale di istruzioni\u003c\/p\u003e\n\u003ctable class=\"product-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifiche\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescrizione\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametri di tensione\u003c\/td\u003e\n\u003ctd\u003e0–3.0 V, con incrementi di 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametri di frequenza\u003c\/td\u003e\n\u003ctd\u003e50–3000 Hz, con incrementi di 1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoglia massima dell'allarme di resistenza della pipetta\u003c\/td\u003e\n\u003ctd\u003e500 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensioni\u003c\/td\u003e\n\u003ctd\u003e19.7 × 12.7 × 7.6 cm (7.75 × 5 × 3 in.) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeso\u003c\/td\u003e\n\u003ctd\u003e0.9 kg (2 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificazioni\u003c\/td\u003e\n\u003ctd\u003eCE, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e\n\u003c!-- section:references --\u003e\n\u003cp\u003eBałakier H, Pedersen RA. Allocazione delle cellule alle linee della massa cellulare interna e del trofoectoderma negli embrioni di topo preimpianto. Dev Biol. 1982 Apr; 90(2):352-62. PMID: 7075865 (\u003ca href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/7075865\"\u003ehttps:\/\/www.ncbi.nlm.nih.gov\/pubmed\/7075865\u003c\/a\u003e)\u003c\/p\u003e\n\u003cp\u003eLawson KA, Pedersen RA. Destino cellulare, movimento morfogenetico e cinetica delle popolazioni dell'endoderma embrionale al momento della formazione dei foglietti germinativi nel topo. Development. 1987 Nov;101(3):627-52. PMID:3502998 (\u003ca href=\"https:\/\/www-ncbi-nlm-nih-gov.myaccess.library.utoronto.ca\/pubmed\/3502998\"\u003ehttps:\/\/www-ncbi-nlm-nih-gov.myaccess.library.utoronto.ca\/pubmed\/3502998\u003c\/a\u003e)\u003c\/p\u003e\n\u003cp\u003eWianny F, Zernicka-Goetz M. Interferenza specifica con la funzione genica mediante RNA a doppio filamento nello sviluppo precoce del topo. Nat Cell Biol. 2000 Feb; 2(2):70-5. PMID:10655585 (\u003ca href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/10655585\"\u003ehttps:\/\/www.ncbi.nlm.nih.gov\/pubmed\/10655585\u003c\/a\u003e)\u003c\/p\u003e\n\u003cp\u003eChazaud C, Yamanaka Y, Pawson T, Rossant J. Segregazione precoce delle linee cellulari tra epiblasto ed endoderma primitivo nelle blastocisti di topo attraverso la via Grb2-MAPK. Dev Cell. 2006 May; 10(5):615- 24. PMID:16678776 (\u003ca href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/16678776\"\u003ehttps:\/\/www.ncbi.nlm.nih.gov\/pubmed\/16678776\u003c\/a\u003e)\u003c\/p\u003e\n\u003cp\u003eSwann K, Campbell K, Yu Y, Saunders C, Lai FA. Uso di una chimera della luciferasi per monitorare l'espressione di PLCzeta negli ovociti di topo. Methods Mol Biol. 2009; 518:17-29. doi: 10.1007\/978-1-59745-202-1_2. PMID:19085135 (\u003ca href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/19085135\"\u003ehttps:\/\/www.ncbi.nlm.nih.gov\/pubmed\/19085135\u003c\/a\u003e)\u003c\/p\u003e\n\u003cp\u003ePosfai E, Petropoulos S, de Barros FRO, Schell JP, Jurisica I, Sandberg R, Lanner F, Rossant J. Plasticità dipendente dalla posizione e dalla segnalazione Hippo durante la segregazione delle linee cellulari nell'embrione precoce di topo. Elife. 2017 Feb 22; 6. pii: e22906. doi: 10.7554\/eLife.22906. PMID: 28226240 (\u003ca href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/28226240\"\u003ehttps:\/\/www.ncbi.nlm.nih.gov\/pubmed\/28226240\u003c\/a\u003e)\u003c\/p\u003e\n\u003cp\u003eGu B, Posfai E, Rossant J. Generazione efficiente di grandi inserzioni mirate mediante microiniezione in embrioni di topo allo stadio a due cellule. Nature Biotechnology 2018 Aug; 36(7):632-637. doi: 10.1038\/nbt.4166. Epub 2018 Jun 11. PMID: 29889212 (\u003ca href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/29889212\"\u003ehttps:\/\/www.ncbi.nlm.nih.gov\/pubmed\/29889212\u003c\/a\u003e)\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Supporto FEMTO MICRO-ePORE™ (300684)","offer_id":42936940232794,"sku":"MICRO-EPORE","price":4600.0,"currency_code":"USD","in_stock":true},{"title":"Supporto NARISH MICRO-ePORE™ (300685)","offer_id":42936940265562,"sku":"MICRO-EPORE","price":4600.0,"currency_code":"USD","in_stock":true},{"title":"Porta WPI MICRO-ePORE™ (300683)","offer_id":42936940200026,"sku":"MICRO-EPORE","price":4600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microepore2_5aec4f7f-2bdb-4970-aab9-174d6cb354b5.jpg?v=1766405633","url":"https:\/\/wpiinc.com\/it\/products\/micro-epore-pinpoint-cell-penetrator","provider":"World Precision Instruments","version":"1.0","type":"link"}