{"title":"Sistemi di rilevamento dell’ossigeno","description":"\u003ch1\u003eSistemi di rilevamento dell’ossigeno\u003c\/h1\u003e\n\u003cstyle\u003e#html-body [data-pb-style=C4123PV]{justify-content:flex-start;display:flex;flex-direction:column;background-position:left top;background-size:cover;background-repeat:no-repeat;background-attachment:scroll}\u003c\/style\u003e\n\u003cdiv data-element=\"main\" data-appearance=\"contained\" data-content-type=\"row\"\u003e\n\u003cdiv data-pb-style=\"C4123PV\" data-element=\"inner\" data-video-fallback-src=\"\" data-video-lazy-load=\"true\" data-video-play-only-visible=\"true\" data-video-loop=\"true\" data-background-type=\"image\" data-background-images=\"{}\" data-parallax-speed=\"0.5\" data-enable-parallax=\"0\"\u003e\n\u003cdiv data-element=\"main\" data-appearance=\"default\" data-content-type=\"text\"\u003e\n\u003cp\u003eStai cercando un sistema di rilevamento elettrochimico dell’ossigeno con elettrodi in fibra di carbonio o rilevatori a fluorescenza per sensori ottici? Offriamo diversi sistemi per il rilevamento dell’ossigeno. Ottieni un rilevamento preciso dell’ossigeno con i nostri innovativi \u003cstrong\u003esistemi di rilevamento dell’ossigeno\u003c\/strong\u003e di WPI. Perfetti per ricercatori e professionisti, questi sistemi offrono precisione e affidabilità senza pari in una vasta gamma di applicazioni. Che tu stia cercando minisensori, microsensori o altri \u003cstrong\u003esistemi di rilevamento \u003c\/strong\u003edell’ossigeno, da WPI troverai un’ampia scelta di modelli.\u003c\/p\u003e\n\u003cp\u003eSe hai bisogno di un sistema di rilevamento elettrochimico con elettrodi in fibra di carbonio o di rilevatori a fluorescenza per sensori ottici, abbiamo una soluzione personalizzabile in base alle tue esigenze. Quando la precisione è fondamentale, i nostri \u003cstrong\u003esistemi di rilevamento dell’ossigeno\u003c\/strong\u003e garantiscono risultati costanti e di alta qualità, ogni volta. Scopri qui sotto i nostri sistemi di rilevamento per saperne di più su ciascun modello e sulle sue funzionalità.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","products":[{"product_id":"oxy-micro-aot-fiber-optic-oxygen-meter-for-microsensors","title":"Misuratore di ossigeno a fibra ottica per microsensori","description":"\u003c!-- section:details --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/OxyMicro.pdf\"\u003eFai clic qui per visualizzare la \u003cstrong\u003eScheda tecnica\u003c\/strong\u003e aggiornata\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eCaratteristiche\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eL’ossigeno non viene consumato durante l’esperimento\u003c\/li\u003e\n\u003cli\u003eImmune alle interferenze elettriche e magnetiche\u003c\/li\u003e\n\u003cli\u003eEccellente stabilità a lungo termine\u003c\/li\u003e\n\u003cli\u003eNon è necessaria una lunga polarizzazione (come per gli elettrodi O2 di tipo Clark)\u003c\/li\u003e\n\u003cli\u003eTempo di risposta rapido \u0026lt; 0.5 s per i sensori MicroTip\u003c\/li\u003e\n\u003cli\u003eDimensioni della sonda dei sensori MicroTip: appena 50 µm\u003c\/li\u003e\n\u003cli\u003eÈ possibile misurare in gas secco\u003c\/li\u003e\n\u003cli\u003eÈ disponibile l’isolamento ottico della punta del sensore, per campioni fluorescenti o fotosinteticamente attivi\u003c\/li\u003e\n\u003cli\u003eI sensori non sono inclusi nel sistema\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eVantaggi\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInsensibile alla stabilità della sorgente luminosa e alle variazioni di intensità, grazie al rilevamento basato sulla durata della luminescenza.\u003c\/li\u003e\n\u003cli\u003eI misuratori compatti e portatili possono essere usati in ambienti interni o esterni\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplicazioni\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eControllo di processo, per esempio degli impianti di imbottigliamento nei birrifici, e controllo qualità delle confezioni (OxyMini)\u003c\/li\u003e\n\u003cli\u003eBiotecnologia, per esempio controllo dei terreni di coltura cellulare e controllo non invasivo dei bioreattori (OxyMini)\u003c\/li\u003e\n\u003cli\u003eImpianto di sensori di ossigeno nel suolo e negli alberi (OxyMini)\u003c\/li\u003e\n\u003cli\u003eProfili di ossigeno nei sedimenti marini, nel suolo o nei tessuti (OxyMicro)\u003c\/li\u003e\n\u003cli\u003eImpianto nei tessuti viventi, come il tessuto cardiaco o muscolare (OxyMicro)\u003c\/li\u003e\n\u003cli\u003eControllo dei terreni di coltura cellulare in biotecnologia (OxyMicro)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInsensibile alla stabilità e all’intensità della sorgente luminosa\u003c\/h2\u003e\n\u003cp\u003eI sistemi convenzionali con sensori di ossigeno a fibra ottica basati su misure di intensità hanno una precisione limitata dalla stabilità della sorgente luminosa e dalle variazioni della luce ambientale. Grazie al rilevamento della durata della luminescenza, le misure non sono influenzate dalla stabilità della sorgente luminosa, dalle variazioni di intensità dovute alla flessione della fibra o dai cambiamenti delle proprietà ottiche del campione (torbidità, indice di rifrazione, colorazione, ecc.).\u003c\/p\u003e\n\u003cp\u003eCalibrazione: i sensori possono essere calibrati con una semplice calibrazione a due punti, al 100% e allo 0% di saturazione in aria.\u003c\/p\u003e\n\u003ch2\u003eMisuratori compatti e portatili, per interni ed esterni\u003c\/h2\u003e\n\u003cp\u003eI misuratori di ossigeno a fibra ottica OxiMini e OxyMicro sono compatti e facili da trasportare. Progettati per l’uso in ambienti interni ed esterni, possono essere collegati a un PC tramite interfaccia RS232. I dati possono essere visualizzati, analizzati e archiviati con il software in dotazione. È disponibile un’ampia gamma di sensori.\u003c\/p\u003e\n\u003ch2\u003eSistemi OxyMicro\u003c\/h2\u003e\n\u003cp\u003eOxyMicro è un misuratore di O2 a un canale per microsensori di O2 a fibra ottica.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMicroTip\u003c\/strong\u003e – \u003cimg style=\"float: right;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/oxyMicroTip_sml_e37ddfcb-60da-4838-a51b-4f9d5d17d42e.jpg?v=1765947313\" alt=\"\" align=\"right\"\u003eMicroTip (501656) è un microsensore di ossigeno ad ago (27 ga.), progettato per applicazioni che richiedono una punta di piccole dimensioni (50 µm) e un tempo di risposta rapido (t90) di 1 s. La punta sensibile all'ossigeno è costituita da una fibra di 140 µm rastremata fino a una punta di 50 µm. Alloggiato all'interno di un ago in acciaio inossidabile lungo 22 mm e con un diametro di 0,4 mm, può perforare un setto di gomma o materiale simile. È ideale per la profilazione dell'ossigeno nei sedimenti e nei biofilm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMicroFlow\u003c\/strong\u003e – \u003cimg style=\"float: right;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/oxyMicroflow_sml_81f476fe-1f6f-43a5-bac6-8a2ba4ae449f.jpg?v=1765947319\" alt=\"\" align=\"right\"\u003eIl sensore di ossigeno MicroFlow (501657) è un sensore chimico miniaturizzato a fibra ottica, ottimizzato per tempi di risposta rapidi (t90 \u0026lt; 1 sec nei gas, \u0026lt; 5 sec nei liquidi). La minuscola sonda ha una punta di 50 µm ed è integrata in una cella a flusso a T, per essere collegata facilmente a tubi esterni tramite adattatori Luer-Lock. È possibile pompare liquidi (come acqua, sangue ecc.) attraverso la cella.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMicroImplant\u003c\/strong\u003e – \u003cimg style=\"float: right;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/oxyMicroImplant_sml_06ecca35-7943-4c87-b737-c1081be8d559.jpg?v=1765947324\" alt=\"\" align=\"right\"\u003eIl sensore di ossigeno MicroImplant (501658) è una sonda impiantabile (IMP) con una punta di 50 µm, una lunghezza della fibra esposta di 5 mm e un diametro della guaina di 900 µm. È stato impiantato con successo in granchi, pesci e terreno.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/OxyMicro-IM-022003.pdf\" target=\"_self\"\u003eManuale di istruzioni OxyMicro\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\u003c!-- section:specifications --\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #0081c2;\"\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMiniTip\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMiniFlow\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMiniSpot\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMicroTip\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMicroFlow\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMicroImplant\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eINTERVALLO DI MISURA\u003cbr\u003eDISCIOLTO\/GASSOSO\u003c\/td\u003e\n\u003ctd\u003e0-45 ppm, 0-100%\u003cbr\u003e0-760 mmHg\u003c\/td\u003e\n\u003ctd\u003e0-45 ppm, 0-100%\u003cbr\u003e0-760 mmHg\u003c\/td\u003e\n\u003ctd\u003e0-45 ppm, 0-100%\u003cbr\u003e0-760 mmHg\u003c\/td\u003e\n\u003ctd\u003e0-45 ppm, 0-100%\u003cbr\u003e0-760 mmHg\u003c\/td\u003e\n\u003ctd\u003e0-45 ppm, 0-100%\u003cbr\u003e0-760 mmHg\u003c\/td\u003e\n\u003ctd\u003e0-45 ppm, 0-100%\u003cbr\u003e0-760 mmHg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEMPO DI RISPOSTA [T₉₀]\u003cbr\u003eDISCIOLTO\/GASSOSO\u003c\/td\u003e\n\u003ctd\u003e40 s\u003cbr\u003e10 s\u003c\/td\u003e\n\u003ctd\u003e40 s\u003cbr\u003e10 s\u003c\/td\u003e\n\u003ctd\u003e40 s\u003cbr\u003e10 s\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2 s\u003cbr\u003e\u0026lt; 0.5 s\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2 s\u003cbr\u003e\u0026lt; 0.5 s\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2 s\u003cbr\u003e\u0026lt; 0.5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eSTERILIZZAZIONE\u003cbr\u003eETOH, H₂O₂\u003cbr\u003eSTERILIZZABILE IN AUTOCLAVE*\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003eY\u003cbr\u003eN\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003eY\u003cbr\u003eY\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003eY\u003cbr\u003eY\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003eY\u003cbr\u003eN\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003eY\u003cbr\u003eY\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003eY\u003cbr\u003eY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDERIVA**\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1%\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1%\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1%\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.3%\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.3%\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003ePRECISIONE***\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e0.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRISOLUZIONE***\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"6\"\u003e2.75 ±0.01 ppm, 9.00 ±0.05 ppm, 220 ±0.15 ppm, 45.0 ±0.25 mmHg,\u003cbr\u003e150 ±0.75 mmHg, 375 ±2.6 mmHg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eINTERVALLO DI TEMPERATURA\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eda -10°C a 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLUNGHEZZA DELL'ASSEMBLAGGIO DELLA SONDA\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"6\"\u003e2.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"7\"\u003e*130°C, 1.5 atm  **100.000 punti dati, 20°C  ***20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266219446362,"sku":"OXY-MICRO-AOT","price":11800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/oxy-micro-aot_1_d293e2ac-b44f-401e-b9af-02bccdf0a2d8.jpg?v=1766399001"},{"product_id":"oxy-mini-aot-fiber-optic-oxygen-meter-for-minisensors","title":"Misuratore di ossigeno a fibra ottica per minisensori","description":"\u003c!-- section:details --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/OxyMini.pdf\" target=\"_self\"\u003eFai clic qui per visualizzare la \u003cstrong\u003eScheda tecnica\u003c\/strong\u003e aggiornata\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eCaratteristiche\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eL’ossigeno non viene consumato durante l’esperimento\u003c\/li\u003e\n\u003cli\u003eImmune alle interferenze elettriche e magnetiche\u003c\/li\u003e\n\u003cli\u003eEccellente stabilità a lungo termine\u003c\/li\u003e\n\u003cli\u003eNon è necessaria una lunga polarizzazione (come per gli elettrodi O2 di tipo Clark)\u003c\/li\u003e\n\u003cli\u003eTempo di risposta rapido: \u0026lt; 0.5 s per i sensori MicroTip\u003c\/li\u003e\n\u003cli\u003eDimensioni della punta dei sensori MicroTip: fino a 50 µm\u003c\/li\u003e\n\u003cli\u003eÈ possibile misurare in gas secco\u003c\/li\u003e\n\u003cli\u003eÈ disponibile l’isolamento ottico della punta del sensore per campioni fluorescenti o fotosinteticamente attivi\u003c\/li\u003e\n\u003cli\u003eI sensori non sono inclusi nel sistema\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eVantaggi\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndipendente dalla stabilità della sorgente luminosa e dalle fluttuazioni di intensità, grazie alla rilevazione del tempo di vita della luminescenza.\u003c\/li\u003e\n\u003cli\u003eI misuratori compatti e portatili possono essere utilizzati in ambienti interni ed esterni\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplicazioni\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eControllo dei processi, come l’imbottigliamento nei birrifici, e controllo qualità delle confezioni (OxyMini)\u003c\/li\u003e\n\u003cli\u003eBiotecnologia: controllo dei terreni di coltura cellulare e controllo non invasivo dei bioreattori (OxyMini)\u003c\/li\u003e\n\u003cli\u003eImpianto di sensori di ossigeno nel suolo e negli alberi (OxyMini)\u003c\/li\u003e\n\u003cli\u003eProfili dell’ossigeno nei sedimenti marini, nei suoli o nei tessuti (OxyMicro)\u003c\/li\u003e\n\u003cli\u003eImpianto in tessuti viventi, come il tessuto cardiaco o muscolare (OxyMicro)\u003c\/li\u003e\n\u003cli\u003eControllo dei terreni di coltura cellulare in biotecnologia (OxyMicro)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIndipendente dalla stabilità e dall’intensità della sorgente luminosa\u003c\/h2\u003e\n\u003cp\u003eI tradizionali sistemi con sensori di ossigeno ottici a fibra basati su misurazioni dell’intensità hanno una precisione limitata dalla stabilità della sorgente luminosa e dalle fluttuazioni della luce ambientale. Grazie alla rilevazione del tempo di vita della luminescenza, le misurazioni non sono influenzate dalla stabilità della sorgente luminosa, dalle fluttuazioni di intensità causate dalla piegatura della fibra o dai cambiamenti delle proprietà ottiche del campione (torbidità, indice di rifrazione, colorazione ecc.).\u003c\/p\u003e\n\u003cp\u003eCalibrazione: i sensori possono essere calibrati con una semplice calibrazione a due punti: saturazione dell’aria al 100% e saturazione dell’aria allo 0%.\u003c\/p\u003e\n\u003ch2\u003eMisuratori compatti e portatili, per interni ed esterni\u003c\/h2\u003e\n\u003cp\u003eI misuratori di ossigeno ottici a fibra OxiMini e OxyMicro sono compatti e facili da trasportare. Progettati per l’uso in ambienti interni ed esterni, possono essere collegati a un PC tramite un’interfaccia RS232. I dati possono essere visualizzati, analizzati e salvati con il software fornito. È disponibile un’ampia gamma di sensori.\u003c\/p\u003e\n\u003ch2\u003eSistemi OxyMini\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOxyMini\u003c\/strong\u003e è un misuratore di O\u003csub\u003e2\u003c\/sub\u003e ottico a fibra a un canale, per minisensori ottici a fibra per O\u003csub\u003e2\u003c\/sub\u003e. Questi sensori si basano su fibre ottiche polimeriche da 2 mm e hanno una lunghezza di 2,5 m.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMiniTip\u003c\/strong\u003e – Questa sonda a immersione (501641) ha un diametro della punta di 4 mm ed è costituita da una fibra ottica polimerica con un rivestimento sensibile all’O2. Il suo intervallo è 0–100%. Ha un tempo di risposta (t90) di circa 40 s.\u003cimg style=\"float: right;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/oxyMiniTip_sml_65860f24-c8a4-4398-8735-7536d2330b4e.jpg?v=1765947337\" alt=\"oxyMiniTip\" width=\"250\" height=\"41\" align=\"right\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMiniFlow\u003c\/strong\u003e – La sonda MiniFlow (501642) è un sensore chimico miniaturizzato a fibra ottica integrato in una cella di flusso standard a forma di T, facilmente collegabile a tubi esterni tramite adattatori Luer-Lock. I liquidi possono essere pompati attraverso la cella. Ha un tempo di risposta (t90) di circa 40 s e un’eccellente stabilità a lungo termine.\u003cimg style=\"float: right;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/oxyMiniFlow_sml_28bc6e12-f670-4fcc-9587-a97e8310d3e2.jpg?v=1765947342\" alt=\"oxyMiniFlow\" width=\"250\" height=\"74\" align=\"right)\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMiniFoil\u003c\/strong\u003e – Materiale sensibile su un disco di supporto in poliestere da 1 cm², applicabile all’interno di fiale di vetro. Misura la concentrazione di ossigeno dall’esterno attraverso la parete della fiala, senza contatto e senza danneggiarla. Illumina la pellicola sensibile con un cavo in fibra ottica di plastica (501644, 01645). La parete della fiala deve essere trasparente e non fluorescente. (Tempo di risposta (t90) di circa 50 s.) Il materiale può essere impiantato nei tessuti animali o in alloggiamenti realizzati su misura. \u003cimg style=\"float: right;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/oxyMiniFoil_sml_fedeffb5-3fa5-46a3-bd95-732f2f44fc2b.jpg?v=1765947348\" alt=\"oxyMiniFoil\" width=\"191\" height=\"162\" align=\"right\"\u003e\u003c\/p\u003e\n\u003cp\u003eIl sistema OxyMini è ottimizzato per applicazioni di controllo dei processi e biotecnologia. Il principio di misurazione del sistema si basa sul rilevamento della concentrazione di ossigeno in funzione della durata della luminescenza, sia in ambienti con fase disciolta sia in fase gassosa. Il misuratore di ossigeno a fibra ottica è compatto e facile da trasportare. È progettato per l’uso in interni ed esterni e può essere collegato a un PC tramite un’interfaccia RS232. I dati possono essere visualizzati, analizzati e archiviati con il software in dotazione. È disponibile una gamma completa di sensori che copre la maggior parte delle applicazioni biomediche.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrincipio di misurazione\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eI sistemi convenzionali di sensori di ossigeno a fibra ottica basati su misurazioni dell’intensità presentano una precisione limitata a causa della stabilità della sorgente luminosa e delle fluttuazioni della luce ambientale. Con il rilevamento della durata della luminescenza, le misurazioni non sono influenzate dalla stabilità della sorgente luminosa, dalle fluttuazioni di intensità causate dalla piegatura della fibra o dai cambiamenti delle proprietà ottiche del campione (torbidità, indice di rifrazione, colorazione, ecc.). Questi vantaggi rendono OxyMini e OxyMicro di WPI i sistemi di ossigeno a fibra ottica più avanzati e affidabili disponibili.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCalibrazione\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eI sensori possono essere calibrati con una semplice calibrazione a due punti: saturazione in aria al 100% e saturazione in aria allo 0%.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/OxyMini-IM-073003r.pdf\" target=\"_self\"\u003eManuale di istruzioni OxyMini\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\u003c!-- section:specifications --\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #0081c2;\"\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMiniSonda\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMiniFlusso\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMiniSpot\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMicrosonda\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMicroflusso\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMicroimpianto\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eINTERVALLO DI MISURA\u003cbr\u003eDISCIOLTO\/GASSOSO\u003c\/td\u003e\n\u003ctd\u003e0-45 ppm, 0-100%\u003cbr\u003e0-760 mmHg\u003c\/td\u003e\n\u003ctd\u003e0-45 ppm, 0-100%\u003cbr\u003e0-760 mmHg\u003c\/td\u003e\n\u003ctd\u003e0-45 ppm, 0-100%\u003cbr\u003e0-760 mmHg\u003c\/td\u003e\n\u003ctd\u003e0-45 ppm, 0-100%\u003cbr\u003e0-760 mmHg\u003c\/td\u003e\n\u003ctd\u003e0-45 ppm, 0-100%\u003cbr\u003e0-760 mmHg\u003c\/td\u003e\n\u003ctd\u003e0-45 ppm, 0-100%\u003cbr\u003e0-760 mmHg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEMPO DI RISPOSTA [T₉₀]\u003cbr\u003eDISCIOLTO\/GASSOSO\u003c\/td\u003e\n\u003ctd\u003e40 s\u003cbr\u003e10 s\u003c\/td\u003e\n\u003ctd\u003e40 s\u003cbr\u003e10 s\u003c\/td\u003e\n\u003ctd\u003e40 s\u003cbr\u003e10 s\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2 s\u003cbr\u003e\u0026lt; 0.5 s\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2 s\u003cbr\u003e\u0026lt; 0.5 s\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2 s\u003cbr\u003e\u0026lt; 0.5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eSTERILIZZAZIONE\u003cbr\u003eETOH, H₂O₂\u003cbr\u003eSTERILIZZABILE IN AUTOCLAVE*\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003eY\u003cbr\u003eN\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003eY\u003cbr\u003eY\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003eY\u003cbr\u003eY\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003eY\u003cbr\u003eN\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003eY\u003cbr\u003eY\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003eY\u003cbr\u003eY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDERIVA**\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1%\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1%\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1%\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.3%\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.3%\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003ePRECISIONE***\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e0.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRISOLUZIONE***\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"6\"\u003e2.75 ±0.01 ppm, 9.00 ±0.05 ppm, 220 ±0.15 ppm, 45.0 ±0.25 mmHg,\u003cbr\u003e150 ±0.75 mmHg, 375 ±2.6 mmHg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eINTERVALLO DI TEMPERATURA\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eda -10°C a 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLUNGHEZZA DELL’ASSEMBLAGGIO DELLA SONDA\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"6\"\u003e2.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"7\"\u003e*130°C, 1.5 atm  **100.000 punti dati, 20°C  ***20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266219479130,"sku":"OXY-MINI-AOT","price":11200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/oxy-mini-aot_d927bea9-d4e2-4acc-ac90-f380e777b0eb.jpg?v=1766399011"},{"product_id":"var-7803-oxygen-sensor","title":"Sensore di ossigeno","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eRilevamento di O2 per analisi in tempo reale\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eRilevatore per sensori ottici basato sul rilevamento della fluorescenza, una valida alternativa ai tradizionali dispositivi di rilevamento chimico\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eMisurazione della durata di fluorescenza, della fase e dell’intensità\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLa fotometria basata su LED rende questa unità conveniente: costa la metà rispetto a sistemi di misurazione della fase comparabili\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eStabilità eccellente, deriva e rumore di fase estremamente ridotti\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCalibrazione, configurazione e controllo semplici\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eKit per il monitoraggio dell’ossigeno, comprensivo di:\n\u003cul\u003e\n\u003cli\u003eSistema di misurazione della fase\u003c\/li\u003e\n\u003cli\u003eSonda di temperatura \u003c\/li\u003e\n\u003cli\u003eSelezionare le patch del sensore al momento dell’ordine\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOpzioni\u003c\/h2\u003e\n\u003ctable style=\"width: 743px;\" border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #0081c2;\"\u003e\n\u003ctd style=\"text-align: center; width: 136.063px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eCodice d’ordine\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 592.938px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eDescrizione\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 136.063px;\"\u003ePatch FLOX\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 592.938px;\"\u003eKit per il monitoraggio non invasivo dell’ossigeno, comprensivo di sistema di misurazione della fase e sonda di temperatura; selezionare le patch del sensore al momento dell’ordine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd style=\"width: 136.063px;\"\u003eSonda FLOX\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 592.938px;\"\u003e\u003cspan class=\"CharOverride-15\"\u003eKit per il monitoraggio dell’ossigeno in situ, comprensivo di sistema di misurazione della fase e sonda di temperatura; selezionare il sensore al momento dell’ordine\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e Vantaggi\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSistema da banco autonomo, insensibile alle piegature della fibra e alla luce parassita\u003c\/li\u003e\n\u003cli\u003eLa facilità di configurazione e controllo, insieme alla stabilità e alla sensibilità, rende questa unità perfetta per gli studi a lungo termine\u003c\/li\u003e\n\u003cli\u003eTre rivestimenti per sonde e patch offrono numerose possibilità\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplicazioni\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eApplicazioni di rilevamento dell’ossigeno che richiedono stabilità e sensibilità alla deriva e che devono rimanere indisturbate per lunghi periodi\u003c\/li\u003e\n\u003cli\u003eMonitoraggio della pressione parziale di O₂ nei gas e nelle soluzioni acquose, nonché nei vapori e nelle soluzioni non acquosi\u003cbr\u003eMonitoraggio di tracce di ossigeno nei gas e nei liquidi\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFLOX\u003c\/strong\u003e è un dispositivo per misurare la durata di fluorescenza, la fase e l’intensità. Utilizza l’eccitazione a LED e il rilevamento con fotodiodo, con selezione della lunghezza d’onda basata su filtri, per facilitare la configurazione e il controllo degli esperimenti.\u003c\/p\u003e\n\u003ch2\u003eUnità autonoma\u003c\/h2\u003e\n\u003cp\u003eL’unità compatta e autonoma è insensibile alle piegature della fibra e alla luce parassita. Offre inoltre un ampio intervallo dinamico dell’intensità ottica, un basso crosstalk ottico ed elettronico e una deriva e un rumore di fase ridotti.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFLOX\u003c\/strong\u003e è particolarmente utile per le applicazioni di rilevamento dell’ossigeno in cui sono importanti la stabilità e la sensibilità alla deriva e in cui i campioni devono rimanere indisturbati per lunghi periodi.\u003c\/p\u003e\n\u003ch2\u003eFacile da configurare, ideale per studi a lungo termine\u003c\/h2\u003e\n\u003cp\u003eIl nuovo sistema di rilevamento dell’ossigeno misura la durata di fluorescenza, la fase e l’intensità, utilizzando l’eccitazione a LED e il rilevamento con fotodiodo, con selezione della lunghezza d’onda basata su filtri. Il sistema è semplice da configurare e controllare. Questa unità è ideale quando, negli esperimenti di rilevamento dell’ossigeno, sono importanti la stabilità e la sensibilità alla deriva. È perfetta per le applicazioni in cui i campioni devono rimanere indisturbati per lunghi periodi.\u003c\/p\u003e\n\u003ch2\u003eTre rivestimenti disponibili per sonde e patch\u003c\/h2\u003e\n\u003cp\u003eI sensori ottici sono costituiti da materiali trasduttori applicati alle estremità delle fibre ottiche o a substrati come patch o cuvette, che modificano le proprietà ottiche in risposta a specifici analiti presenti nell’ambiente circostante.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOXY\u003c\/strong\u003e–Il sensore standard per l’ossigeno, progettato per monitorare la pressione parziale di ossigeno nei gas e nelle soluzioni acquose, è una sonda a fluorescenza in fibra ottica con una punta rivestita con un rivestimento proprietario per il rilevamento dell’ossigeno.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHIOXY\u003c\/strong\u003e–Progettato per monitorare la pressione parziale dell'ossigeno in vapori e soluzioni non acquosi. La composizione chimica del rivestimento del sensore è compatibile con oli, alcoli e vapori e liquidi a base di idrocarburi.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFOSPOR\u003c\/strong\u003e–Una nuova generazione di rivestimenti sensibili per sensori può essere utilizzata per monitorare tracce di ossigeno in gas e liquidi.\u003c\/p\u003e\n\u003cp\u003eLe sonde del sensore di ossigeno hanno un basso consumo energetico e offrono elevata sensibilità, reversibilità e stabilità, caratteristiche ideali per il monitoraggio remoto. Il sottile rivestimento sulle punte delle sonde non consuma ossigeno, consentendo il contatto continuo con il campione. Sono ideali per campioni viscosi e non risentono delle interferenze causate da variazioni di pH, forza ionica o salinità, né dal biofouling.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/10_orig_71ef576f-84ef-40c5-8472-e98fd8fc684e.png?v=1765948947\" alt=\"misurazioni dell'ossigeno\" width=\"400\" height=\"237\"\u003e\u003c\/p\u003e\n\u003cp\u003eIl software FLOX visualizza le misurazioni dell'ossigeno su un PC collegato.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003c!-- section:specifications --\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 200px;\"\u003e\u003cstrong\u003eSpecifiche delle sonde\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eFormulazione OXY\u003c\/strong\u003e \u003cstrong\u003e(rivestimento per uso generale)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eFormulazione FOSPOR\u003c\/strong\u003e \u003cstrong\u003e(ad alta sensibilità per bassi livelli di \u003c\/strong\u003e\u003cstrong\u003eO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eFormulazione HIOXY\u003c\/strong\u003e \u003cstrong\u003e(per ambienti con idrocarburi)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eO\u003csub\u003e2\u003c\/sub\u003eIntervallo % (a 1 ATM)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003ctd\u003e0-\u0026lt;10%\u003c\/td\u003e\n\u003ctd\u003e0-20.9%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntervallo DO (ppm a 1 ATM)\u003c\/td\u003e\n\u003ctd\u003e0-40 ppm\u003c\/td\u003e\n\u003ctd\u003e0-4 ppm\u003c\/td\u003e\n\u003ctd\u003e0-8 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eIntervallo di temperatura\u003c\/td\u003e\n\u003ctd\u003e-50-+80ºC per le sonde\u003c\/td\u003e\n\u003ctd\u003e0-+60ºC per le sonde\u003c\/td\u003e\n\u003ctd\u003e-50-+60ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0-60 ºC per i patch\u003c\/td\u003e\n\u003ctd\u003e0-60ºC per i patch\u003c\/td\u003e\n\u003ctd\u003eN\/D\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eO\u003csub\u003e2\u003c\/sub\u003eRisoluzione %\u003c\/td\u003e\n\u003ctd\u003e100 ppm in gas\u003c\/td\u003e\n\u003ctd\u003e10 ppm in gas\u003c\/td\u003e\n\u003ctd\u003e100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRisoluzione DO (a temperatura ambiente)\u003c\/td\u003e\n\u003ctd\u003e4 ppb\u003c\/td\u003e\n\u003ctd\u003e0,4 ppb\u003c\/td\u003e\n\u003ctd\u003e4 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eO\u003csub\u003e2\u003c\/sub\u003ePrecisione %\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5% della lettura\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5% della lettura\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5% della lettura\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrecisione DO\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5% della lettura\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5% della lettura\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5% della lettura\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eLivello minimo rilevabile in gas\u003c\/td\u003e\n\u003ctd\u003e0.01% - 0.05%\u003c\/td\u003e\n\u003ctd\u003e0.001% - 0.01%\u003c\/td\u003e\n\u003ctd\u003e0.01% - 0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTempo di risposta (in gas)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 secondo\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 30-60 secondi\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 secondo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eTempo di risposta con rivestimento protettivo in gas\u003c\/td\u003e\n\u003ctd\u003e45-60 secondi\u003c\/td\u003e\n\u003ctd\u003e60-90 secondi\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTempo di risposta in acqua pura\u003c\/td\u003e\n\u003ctd\u003e30-45 secondi\u003c\/td\u003e\n\u003ctd\u003e60-90 secondi\u003c\/td\u003e\n\u003ctd\u003e~45 secondi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 200px;\"\u003e\u003cstrong\u003eSpecifiche dei patch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eFormulazione OXY\u003c\/strong\u003e \u003cstrong\u003e(rivestimento per uso generale)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eFormulazione FOSPOR\u003c\/strong\u003e \u003cstrong\u003e(ad alta sensibilità per bassi livelli di \u003c\/strong\u003e\u003cstrong\u003eO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eFormulazione HIOXY\u003c\/strong\u003e \u003cstrong\u003e(per ambienti con idrocarburi)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eO\u003csub\u003e2\u003c\/sub\u003eIntervallo % (a 1 ATM)\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003ctd\u003e0-10%\u003c\/td\u003e\n\u003ctd\u003e0-20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntervallo DO (ppm a 1 ATM)  \u003c\/td\u003e\n\u003ctd\u003e0-40 ppm\u003c\/td\u003e\n\u003ctd\u003e0-4 ppm\u003c\/td\u003e\n\u003ctd\u003e0-8 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eIntervallo di temperatura\u003c\/td\u003e\n\u003ctd\u003e-20 a +60 ºC per i patch\u003c\/td\u003e\n\u003ctd\u003e0 a +60 ºC per i patch\u003c\/td\u003e\n\u003ctd\u003e-20 a +60 ºC per i patch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eO\u003csub\u003e2\u003c\/sub\u003eRisoluzione % (media su 20 sec)\u003c\/td\u003e\n\u003ctd\u003e0.05%\u003c\/td\u003e\n\u003ctd\u003e0.01%\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003e (con media su 30 sec)\u003c\/td\u003e\n\u003ctd\u003e0.05%\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRisoluzione DO (a temperatura ambiente)\u003c\/td\u003e\n\u003ctd\u003e20 ppb\u003c\/td\u003e\n\u003ctd\u003e4 ppb\u003c\/td\u003e\n\u003ctd\u003e20 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eO\u003csub\u003e2\u003c\/sub\u003ePrecisione %\u003c\/td\u003e\n\u003ctd\u003e5% della lettura\u003c\/td\u003e\n\u003ctd\u003e5% della lettura\u003c\/td\u003e\n\u003ctd\u003e5% della lettura\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrecisione DO\u003c\/td\u003e\n\u003ctd\u003e5% della lettura\u003c\/td\u003e\n\u003ctd\u003e5% della lettura\u003c\/td\u003e\n\u003ctd\u003e5% della lettura\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eLivello minimo rilevabile \u003c\/td\u003e\n\u003ctd\u003e0.1% O\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.01% O\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e  (con media su 30 sec)\u003c\/td\u003e\n\u003ctd\u003e0.1% O\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eLivello minimo rilevabile in acqua (a temperatura ambiente)\u003c\/td\u003e\n\u003ctd\u003e40 ppb    \u003c\/td\u003e\n\u003ctd\u003e4 ppb\u003c\/td\u003e\n\u003ctd\u003e40 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTempo di risposta (in gas)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1 secondo\u003c\/td\u003e\n\u003ctd\u003e30-60 secondi\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1 secondo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003e\n\u003cp\u003eTempo di risposta con rivestimento protettivo in gas\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e~30-45 secondi\u003c\/td\u003e\n\u003ctd\u003e~60-90 secondi\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTempo di risposta in acqua pura\u003c\/td\u003e\n\u003ctd\u003e~45 secondi\u003c\/td\u003e\n\u003ctd\u003e~60-90 secondi\u003c\/td\u003e\n\u003ctd\u003e~30-45 secondi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 200px;\"\u003e\u003cstrong\u003eStabilità (LED continuo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eFormulazione OXY\u003c\/strong\u003e \u003cstrong\u003e(rivestimento per uso generale)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eFormulazione FOSPOR\u003c\/strong\u003e \u003cstrong\u003e(ad alta sensibilità per bassi livelli di \u003c\/strong\u003e\u003cstrong\u003eO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eFormulazione HIOXY\u003c\/strong\u003e \u003cstrong\u003e(per ambienti con idrocarburi)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eStabilità nel tempo (Tau)\u003c\/td\u003e\n\u003ctd\u003e0,0006 usec\/ HR\u003c\/td\u003e\n\u003ctd\u003e0,003 usec\/ HR\u003c\/td\u003e\n\u003ctd\u003e0,0002 usec\/HR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStabilità dell'ossigeno %\u003c\/td\u003e\n\u003ctd\u003e0,01% HR\u003c\/td\u003e\n\u003ctd\u003e0,005% HR\u003c\/td\u003e\n\u003ctd\u003e0,007% HR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 200px;\"\u003e\u003cstrong\u003eGuida alla sterilizzazione\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eFormulazione OXY\u003c\/strong\u003e \u003cstrong\u003e(rivestimento per uso generale)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eFormulazione FOSPOR\u003c\/strong\u003e \u003cstrong\u003e(ad alta sensibilità per bassi livelli di \u003c\/strong\u003e\u003cstrong\u003eO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eFormulazione HIOXY\u003c\/strong\u003e \u003cstrong\u003e(per ambienti con idrocarburi)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eFattore di forma\u003c\/td\u003e\n\u003ctd\u003eSonde\/patch\u003c\/td\u003e\n\u003ctd\u003eSonde\/patch\u003c\/td\u003e\n\u003ctd\u003eSonde\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoclavabile\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNon ancora determinato\u003c\/td\u003e\n\u003ctd\u003eSì\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eCalibrazione\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eÈ necessario un ripristino a punto singolo dopo la sterilizzazione\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGamma\u003c\/td\u003e\n\u003ctd\u003eSì\u003c\/td\u003e\n\u003ctd\u003eNon ancora determinato\u003c\/td\u003e\n\u003ctd\u003eSì\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDisponibili anche altre opzioni\u003c\/h2\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"2\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAL300\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUna sonda a fibra ottica con diametro esterno di 500 µm (diametro del nucleo di 300 µm) e guaina in alluminio, per applicazioni che richiedono un'elevata risoluzione spaziale. Gruppo di fibre con guaina in alluminio da 300 µm; diametro esterno di 500 µm, lunghezza di 1 m\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/11_orig.jpg\" alt=\"\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOR125\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLa OR125 è una sonda a fibra ottica con diametro esterno di 1\/8\", utilizzata come ricambio diretto per gli elettrodi O2 con diametro esterno di 1\/8\".\u003cbr\u003eFibra ottica da 100 µm, ghiera in acciaio inossidabile; diametro esterno di 3,175 mm, lunghezza di 63,5 mm\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/12_orig.jpg\" alt=\"\" width=\"131\" height=\"96\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eP1600\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003eLa PI600 è una sonda a fibra ottica con guaina in silicone e rivestimento in poliimmide, utilizzata in ambienti in cui è necessaria una sonda non metallica.\u003cbr\u003eFibra ottica da 200 o 600 µm con guaina in silicone; diametro esterno di 710 µm, lunghezza di 2 m\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/13_orig.jpg\" alt=\"\" width=\"125\" height=\"68\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOR125G e OR125GT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQueste sonde sono sonde a fibra ottica con diametro esterno di 1\/8\", utilizzate come ricambio diretto per gli elettrodi O2 con diametro esterno di 1\/8\".\u003cbr\u003eFibra ottica da 1000 µm, ghiera in acciaio inossidabile; diametro esterno di 3,175 mm, lunghezza di 63,5 mm\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/14_orig.jpg\" alt=\"\" width=\"120\" height=\"100\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSonda sensore R\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFibra da 1000 µm in una ghiera in acciaio inossidabile da 1\/16\"; diametro esterno di 1,587 mm, lunghezza di 152,4 mm\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/15_orig.jpg\" alt=\"\" width=\"128\" height=\"89\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Kit di monitoraggio non invasivo dell’ossigeno","offer_id":42266308313178,"sku":"FLOX-PATCH","price":4473.0,"currency_code":"USD","in_stock":true},{"title":"Kit per il monitoraggio dell’ossigeno in situ","offer_id":42266308345946,"sku":"FLOX-PROBE","price":5812.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/flox-al300_80472b1a-4e00-4602-9431-6de9723c3169.jpg?v=1766401214"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/collections\/pubo2-systemes.jpg?v=1793787371","url":"https:\/\/wpiinc.com\/it\/collections\/oxygen-detection-systems.oembed","provider":"World Precision Instruments","version":"1.0","type":"link"}