{"title":"Biochip per l’adesione cellulare e la coltura in flusso","description":"\u003cp\u003e\u003cspan\u003eWPI offre biochip Cellix per un'ampia gamma di applicazioni nelle scienze della vita, tra cui studi sui biofilm, sullo stress di taglio, sui ligandi, test di rotolamento e adesione e studi su singole cellule.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eBiochip per l'adesione e la coltura cellulare in condizioni di flusso\u003c\/h2\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/Vena8%20Fluoro1.png\" alt=\"\" width=\"200\" height=\"148\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003ch3\u003eBiochip Vena8 Fluoro+\u003c\/h3\u003e\n\u003cp\u003eAdesione cellula-ligando \/ cellula-proteina\u003c\/p\u003e\n\u003cp\u003eOgni biochip contiene 8 capillari paralleli che possono essere rivestiti con diverse molecole di adesione per studiare le interazioni recettore-ligando cellulare (ovvero le interazioni cellula-matrice) in condizioni di flusso di taglio.  \u003c\/p\u003e\n\u003cp\u003eQuesti biochip sono compatibili con la microscopia confocale.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn flusso di taglio\u003c\/li\u003e\n\u003cli\u003eBiochip monouso\u003c\/li\u003e\n\u003cli\u003eTest di adesione e rotolamento cellulare su canali rivestiti con ligandi\/proteine\u003c\/li\u003e\n\u003cli\u003eIdeale per test di aggregazione piastrinica e trombosi\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca title=\"Vena8 Fluoro+ Biochip Technical Notes\" href=\"https:\/\/www.wpi-europe.com\/downloads\/content\/Technical%20Note%20Vena8%20Fluoro%20Biochip.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/icon_download_pdf.png\" alt=\"\" width=\"40\" height=\"48\"\u003e\u003c\/a\u003e Note tecniche del biochip Vena8 Fluoro+\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Vena8 Fluoro+ Biochip Protocol Notes\" href=\"https:\/\/www.wpi-europe.com\/downloads\/content\/Protocol%20Vena8%20Fluoro%20Biochip.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/icon_download_pdf.png\" alt=\"\" width=\"40\" height=\"48\"\u003e\u003c\/a\u003e Note sul protocollo del biochip Vena8 Fluoro+\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCodice prodotto\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescrizione del prodotto\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/pumps--microinjection\/microfluidic-pumps--biochips\/biochips\/biochips-for-cell-adhesion--culture-under-flow.aspx#productlistitem8204\"\u003eV8CF-400-100-02P5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBiochip Vena8 Fluoro+ confezione da 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/pumps--microinjection\/microfluidic-pumps--biochips\/biochips\/biochips-for-cell-adhesion--culture-under-flow.aspx#productlistitem8203\"\u003eV8CF-400-100-02P10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBiochip Vena8 Fluoro+ confezione da 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/Vena8%20Endothelial.png\" alt=\"\" width=\"200\" height=\"143\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003ch3\u003eBiochip Vena8 Endothelial+\u003c\/h3\u003e\n\u003cp\u003eColtura cellulare e adesione cellula-cellula\u003c\/p\u003e\n\u003cp\u003eOgni biochip contiene 8 capillari paralleli, che possono essere seminati con cellule endoteliali per coltivare 8 monostrati in parallelo e studiare successivamente le interazioni cellula-cellula in condizioni di flusso di taglio.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn flusso di taglio\u003c\/li\u003e\n\u003cli\u003eBiochip monouso\u003c\/li\u003e\n\u003cli\u003eColtura di cellule endoteliali in monostrati in camere a flusso con microcanali\u003c\/li\u003e\n\u003cli\u003eTest di adesione cellula-cellula in flusso di taglio\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca title=\"Vena8 Endothelial+ Biochip Technical Notes\" href=\"https:\/\/www.wpi-europe.com\/downloads\/content\/Tech%20Note_Vena8%20Endothelial%20Biochip.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/icon_download_pdf.png\" alt=\"\" width=\"40\" height=\"48\"\u003e\u003c\/a\u003e Note tecniche del biochip Vena8 Endothelial+\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Vena8 Endothelial+ Biochip Protocol Notes\" href=\"https:\/\/www.wpi-europe.com\/downloads\/content\/Protocol_Vena8%20Endothelial%20Biochip.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/icon_download_pdf.png\" alt=\"\" width=\"40\" height=\"48\"\u003e\u003c\/a\u003e Note sul protocollo del biochip Vena8 Endothelial+\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCodice prodotto\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescrizione del prodotto\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/pumps--microinjection\/microfluidic-pumps--biochips\/biochips\/biochips-for-cell-adhesion--culture-under-flow.aspx#productlistitem8206\"\u003eV8EP-800-120-02P5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBiochip Vena8 Endothelial+ confezione da 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/pumps--microinjection\/microfluidic-pumps--biochips\/biochips\/biochips-for-cell-adhesion--culture-under-flow.aspx#productlistitem8205\"\u003eV8EP-800-120-02P10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBiochip Vena8 Endothelial+ confezione da 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/Vena8%20Glass1.png\" alt=\"\" width=\"200\" height=\"144\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/Vena8GCS%20(3).png\" alt=\"\" width=\"200\" height=\"133\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003ch3\u003eBiochip Vena8 con vetrini coprioggetto in vetro\u003c\/h3\u003e\n\u003cp\u003eAdesione cellula-ligando e cellula-cellula\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn flusso di taglio\u003c\/li\u003e\n\u003cli\u003eBiochip monouso\u003c\/li\u003e\n\u003cli\u003eFlessibilità grazie al vetrino coprioggetto in vetro fornito non fissato.\u003c\/li\u003e\n\u003cli\u003eI vetrini coprioggetto in vetro possono essere trattati con ioni Cu2+ chelati, legati al rivestimento ad alta densità di PEG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOpzioni:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eVetrino coprioggetto: \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVetrino coprioggetto in vetro aderente\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVetrino coprioggetto in vetro non aderente\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStrato adesivo aderente\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrattamento superficiale del chip:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eNon trattato\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrattato con tag istidinico Cu2+\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrattato con gruppo uscente NHS sul rivestimento a spazzola di PEG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdatto per portate:\n\u003cul\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePortate basse (dimensioni del canale: 1600 µm x 160 µm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePortate elevate (dimensioni del canale: 800 µm x 80 µm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca title=\"Vena8 Biochip With Glass Coverslips Technical Notes\" href=\"https:\/\/www.wpi-europe.com\/downloads\/content\/Technical%20Note%20Vena8%20Glass%20Coverslip%20Biochip.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/icon_download_pdf.png\" alt=\"\" width=\"40\" height=\"48\"\u003e\u003c\/a\u003e Note tecniche del biochip Vena8 con vetrini coprioggetto in vetro\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Vena8 Biochip With Glass Coverslips Low Shear Flow Rates\" href=\"https:\/\/www.wpi-europe.com\/downloads\/content\/Vena8%20Glass%20Coverslip%20Low%20Shear%20Flow%20Rates.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/icon_download_pdf.png\" alt=\"\" width=\"40\" height=\"48\"\u003e\u003c\/a\u003e Biochip Vena8 con vetrini coprioggetto in vetro per portate basse a basso sforzo di taglio\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Vena8 Biochip With Glass Coverslips High Shear Flow Rates\" href=\"https:\/\/www.wpi-europe.com\/downloads\/content\/Vena8%20Glass%20Coverslip%20High%20Shear%20Flow%20Rates.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/icon_download_pdf.png\" alt=\"\" width=\"40\" height=\"48\"\u003e\u003c\/a\u003e Biochip Vena8 con vetrini coprioggetto in vetro per portate elevate a elevato sforzo di taglio\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCodice prodotto\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescrizione del prodotto\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/pumps--microinjection\/microfluidic-pumps--biochips\/biochips\/biochips-for-cell-adhesion--culture-under-flow.aspx#productlistitem8220\"\u003eV8GCS-A-NT-1600-160-P10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eVena8 con vetrini coprioggetto in vetro aderenti, non trattato; portate basse; confezione da 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/pumps--microinjection\/microfluidic-pumps--biochips\/biochips\/biochips-for-cell-adhesion--culture-under-flow.aspx#productlistitem8221\"\u003eV8GCS-A-NT-800-80-P10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eVena8 con vetrini coprioggetto in vetro aderenti, non trattato; portate elevate; confezione da 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/pumps--microinjection\/microfluidic-pumps--biochips\/biochips\/biochips-for-cell-adhesion--culture-under-flow.aspx#productlistitem8222\"\u003eV8GCS-NA-NT-1600-160-P10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eVena8 con vetrini coprioggetto in vetro non aderenti, non trattato; portate basse; confezione da 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/pumps--microinjection\/microfluidic-pumps--biochips\/biochips\/biochips-for-cell-adhesion--culture-under-flow.aspx#productlistitem8223\"\u003eV8GCS-NA-NT-800-80-P10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eVena8 con vetrini coprioggetto in vetro non aderenti, non trattato; portate elevate; confezione da 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/pumps--microinjection\/microfluidic-pumps--biochips\/biochips\/biochips-for-cell-adhesion--culture-under-flow.aspx#productlistitem8224\"\u003eV8-Adhesive-1600-160-P10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eVena8 con strato inferiore adesivo; portate basse; confezione da 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/pumps--microinjection\/microfluidic-pumps--biochips\/biochips\/biochips-for-cell-adhesion--culture-under-flow.aspx#productlistitem8225\"\u003eV8-Adhesive-800-80-P10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eVena8 con strato inferiore adesivo; portate elevate; confezione da 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/pumps--microinjection\/microfluidic-pumps--biochips\/biochips\/biochips-for-cell-adhesion--culture-under-flow.aspx#productlistitem8216\"\u003eV8GCS-A-T-Cu2+Htag-1600-160-P10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eVena8 con vetrini coprioggetto in vetro aderenti, trattato con tag istidinico Cu2+; portate basse; confezione da 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/pumps--microinjection\/microfluidic-pumps--biochips\/biochips\/biochips-for-cell-adhesion--culture-under-flow.aspx#productlistitem8217\"\u003eV8GCS-A-T-Cu2+Htag-800-80-P10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eVena8 con vetrini coprioggetto in vetro aderenti, trattato con tag istidinico Cu2+; portate elevate; confezione da 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/pumps--microinjection\/microfluidic-pumps--biochips\/biochips\/biochips-for-cell-adhesion--culture-under-flow.aspx#productlistitem8218\"\u003eV8GCS-A-T-NHS_02-1600-160-P10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eVena8 con vetrini coprioggetto in vetro aderenti, trattati con gruppo uscente NHS su strato di PEG; portate ridotte; confezione da 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/pumps--microinjection\/microfluidic-pumps--biochips\/biochips\/biochips-for-cell-adhesion--culture-under-flow.aspx#productlistitem8219\"\u003eV8GCS-A-T-NHS_02-800-80-P10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eVena8 con vetrini coprioggetto in vetro aderenti, trattati con gruppo uscente NHS su strato di PEG; portate elevate; confezione da 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/Vena%20Delta%20Y1.jpg\" alt=\"\" width=\"200\" height=\"202\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003ch3\u003eBiochip Vena Delta Y1\u003c\/h3\u003e\n\u003cp\u003eI biochip VenaDeltaY1 contengono microcanali ramificati per il flusso doppio e la doppia iniezione dei campioni.  Ideali per studiare i gradienti chemiotattici, il flusso doppio, il flusso multilaminare e la diffusione.\u003c\/p\u003e\n\u003cp\u003eOgni biochip contiene 4 capillari a forma di Y disposti in parallelo, rivestibili con diverse molecole di adesione per studiare le interazioni recettore-ligando delle cellule (ovvero le interazioni cellula-matrice) in condizioni di flusso di taglio con doppia iniezione (esperimenti di chemiotassi), oppure per analizzare la formazione di trombi nel ramo del canale a Y.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGiunzione ramificata a Y alla porta di ingresso\u003c\/li\u003e\n\u003cli\u003eSimulano reti microvascolari ramificate\u003c\/li\u003e\n\u003cli\u003eTest di chemiotassi, flusso doppio, flusso multilaminare e diffusione\u003c\/li\u003e\n\u003cli\u003eScelta tra canali di 400 µm (larghezza) x 100 µm (profondità) o 800 µm (larghezza) x 120 µm (profondità)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca title=\"Vena8 Delta Y BiochipTechnical Notes\" href=\"https:\/\/www.wpi-europe.com\/downloads\/content\/Technical%20Note%20VenaDeltaY%20Biochip.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/icon_download_pdf.png\" alt=\"\" width=\"40\" height=\"48\"\u003e\u003c\/a\u003e Biochip Vena8 Delta Y - Note tecniche\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCodice prodotto\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescrizione del prodotto\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/pumps--microinjection\/microfluidic-pumps--biochips\/biochips\/biochips-for-cell-adhesion--culture-under-flow.aspx#productlistitem8208\"\u003eV4DY1-400-100-1-1P10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eConfezione da 10 biochip VenaDeltaY1 (ordine minimo di 6 confezioni) - dimensioni del canale: 400 µm (larghezza) x 100 µm (profondità)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/pumps--microinjection\/microfluidic-pumps--biochips\/biochips\/biochips-for-cell-adhesion--culture-under-flow.aspx#productlistitem8209\"\u003eV4DY1-800-120-1-1P10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eConfezione da 10 biochip VenaDeltaY1 (ordine minimo di 6 confezioni) - dimensioni del canale: 800 µm (larghezza) x 120 µm (profondità)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/Vena%20Delta%20Y2.jpg\" alt=\"\" width=\"200\" height=\"199\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003ch3\u003eBiochip Vena Delta Y2\u003c\/h3\u003e\n\u003cp\u003eI biochip VenaDeltaY2 contengono microcanali ramificati per il flusso doppio e la doppia iniezione dei campioni.  Ideali per studiare i gradienti chemiotattici, il flusso doppio, il flusso multilaminare e la diffusione.\u003c\/p\u003e\n\u003cp\u003eOgni biochip contiene 4 capillari a forma di Y disposti in parallelo a entrambe le estremità, rivestibili con diverse molecole di adesione per studiare le interazioni recettore-ligando delle cellule (ovvero le interazioni cellula-matrice) in condizioni di flusso di taglio con doppia iniezione (esperimenti di chemiotassi), oppure per analizzare la formazione di trombi nel ramo del canale a Y.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGiunzione ramificata a Y alle porte di ingresso e di uscita\u003c\/li\u003e\n\u003cli\u003eSimulano reti microvascolari ramificate\u003c\/li\u003e\n\u003cli\u003eTest di chemiotassi, flusso doppio, flusso multilaminare e diffusione\u003c\/li\u003e\n\u003cli\u003eDimensioni dei canali:  600 µm (larghezza) x 100 µm (profondità)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca title=\"Vena8 Delta Y BiochipTechnical Notes\" href=\"https:\/\/www.wpi-europe.com\/downloads\/content\/Technical%20Note%20VenaDeltaY%20Biochip.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/icon_download_pdf.png\" alt=\"\" width=\"40\" height=\"48\"\u003e\u003c\/a\u003e Biochip Vena8 Delta Y - Note tecniche\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCodice prodotto\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescrizione del prodotto\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/https\/\/www.wpi-europe.com\/products\/pumps--microinjection\/microfluidic-pumps--biochips\/biochips\/biochips-for-cell-adhesion--culture-under-flow.aspx#productlistitem8210\"\u003eV4DY2-600-100-2-1P10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eConfezione da 10 biochip VenaDeltaY2 (ordine minimo di 6 confezioni)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003ch3\u003eBiochip Vena Delta T\u003c\/h3\u003e\n\u003cp\u003eIl biochip VenaDeltaT contiene 4 capillari a forma di giunzione a T disposti in parallelo, rivestibili con diverse molecole di adesione per studiare le interazioni recettore-ligando delle cellule (ovvero le interazioni cellula-matrice) in condizioni di flusso di taglio con doppia iniezione (esperimenti di chemiotassi), oppure per analizzare la formazione di trombi nel ramo del canale a T.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e4 capillari a forma di giunzione a T\u003c\/li\u003e\n\u003cli\u003eDimensioni dei canali:  400 µm (larghezza) x 100 µm (profondità)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCodice prodotto\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescrizione del prodotto\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/pumps--microinjection\/microfluidic-pumps--biochips\/biochips\/biochips-for-cell-adhesion--culture-under-flow.aspx#productlistitem8211\"\u003eV4DT-400-100-1-1P10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eConfezione da 10 biochip VenaDeltaT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003ch3\u003eBiochip Vena Delta W\u003c\/h3\u003e\n\u003cp\u003eIl biochip VenaDeltaW contiene 2 capillari a forma di giunzione a W e 1 capillare a forma di giunzione a Y al centro, rivestibili con diverse molecole di adesione per studiare le interazioni recettore-ligando delle cellule (ovvero le interazioni cellula-matrice) in condizioni di flusso di taglio con doppia iniezione (esperimenti di chemiotassi), oppure per analizzare la formazione di trombi nel ramo del canale a W o a Y.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 capillari a forma di giunzione a W\u003c\/li\u003e\n\u003cli\u003e1 capillare a forma di giunzione a Y\u003c\/li\u003e\n\u003cli\u003eDimensioni dei canali:  400 µm (larghezza) x 100 µm (profondità)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCodice prodotto\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescrizione del prodotto\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/pumps--microinjection\/microfluidic-pumps--biochips\/biochips\/biochips-for-cell-adhesion--culture-under-flow.aspx#productlistitem8212\"\u003eVDW-400-100-1-1P10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eConfezione da 10 biochip VenaDeltaW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","products":[],"url":"https:\/\/wpiinc.com\/it\/collections\/biochips-for-cell-adhesion-culture-under-flow.oembed","provider":"World Precision Instruments","version":"1.0","type":"link"}