{"title":"4U  Pressure","description":"\u003ch1\u003e\u003cspan\u003e4U Pressure Pump for Microfluidics\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003e4U Pump series is a four channel microfluidic pressure pump controlled by SmartFlo software that can be run from a PC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/4U%20Banner.png\" alt=\"\" width=\"650\" height=\"141\"\u003e\u003c\/p\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e4U is a four-channel precision, microfluidic, pressure pump for a variety of microfluidic applications, where accurate and stable flow rate delivery is required. The pressure pump component is based on controlled air injection. SmartFlo application executed on the PC via a LabVIEW based interface communicates with the four separate channels of the 4U pump allowing simultaneous control and independent programming of each pump’s flow profile.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFAST RESPONSE and fast settling time\u003c\/li\u003e\n\u003cli\u003ePULSE-FREE down to uL\/min with flow sensor\u003c\/li\u003e\n\u003cli\u003ePROGRAMMABLE flow profiles with any combination of constant, ramp, sine and step\u003c\/li\u003e\n\u003cli\u003eEASY INTEGRATION with your own software - LabVIEW, C++, Python, etc\u003c\/li\u003e\n\u003cli\u003eFLOW RATES: 1µL\/min - 1 mL\/min\u003c\/li\u003e\n\u003cli\u003eINPUT PRESSURE: up to 10 bar or 145 psi - external compressor or vacuum pump required\u003c\/li\u003e\n\u003cli\u003eCLOSED-LOOP FEEDBACK: Flow sensors provide active feedback and precise flow control\u003c\/li\u003e\n\u003cli\u003eEASY TO USE: simple software control via SmartFlo app for your PC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA 4U pressure pump setup will look like this\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/4U%20Pressure%20Pump%20Setup.jpg\" alt=\"\" width=\"650\" height=\"326\"\u003e\u003c\/p\u003e\n\u003cp\u003eTo select a 4U pump configuration you need to used the selection chart below\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/4U-Configuration%202.png\" alt=\"\" width=\"650\" height=\"516\"\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eSelect whether you need an external pressure source included or you already have your own\u003c\/li\u003e\n\u003cli\u003eSelect the flow sensor for each channel based on the flow rate required. When selecting the 4U model below add the four flow sensors you need in the comments section\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Pressure\u003c\/td\u003e\n\u003ctd\u003eUp to 10 bar or 145PSI or vacuum -0.9 bar\u003csup\u003e(1)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolumetric Flow Rates\u003c\/td\u003e\n\u003ctd\u003e1 μL\/min to 1 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Direction\u003c\/td\u003e\n\u003ctd\u003eUnidirectional (Push or Pull)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse-free flow rate for microfluidic applications\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 μL\/min - 80 μL\/min (± 120 nL\/min)\u003csup\u003e(2)\u003c\/sup\u003e\u003c\/p\u003e\n\u003cp\u003e10 μL\/min - 1 mL\/min (± 2 μL\/min)\u003csup\u003e(3)\u003c\/sup\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow feedback options\u003c\/td\u003e\n\u003ctd\u003ePressure-flow combined or Pressure only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFast response\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Control\u003c\/td\u003e\n\u003ctd\u003eSmartFlo App running on PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e230 mm (L) x 193 mm (W) x 85 mm (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight of pump\u003c\/td\u003e\n\u003ctd\u003e2.5 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirement\u003c\/td\u003e\n\u003ctd\u003e110\/220V - 50\/60Hz | 60W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e(1) External compressor or vacuum required.\u003cbr\u003e(2) Using a 80µL\/min sensor (FS80.0)\u003cbr\u003e(3) Using a 1mL\/min sensor (FS-1000)\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDroplet Generation: high throughput droplet micro-reactor generation\u003c\/li\u003e\n\u003cli\u003eOrgan-on-chip studies\u003c\/li\u003e\n\u003cli\u003eVolatile Organic Compound (VOC) experimental set-ups\u003c\/li\u003e\n\u003cli\u003eShear based cell rolling, adhesion and transmigration assays on ligand-coated surface or on endothelial cells.\u003c\/li\u003e\n\u003cli\u003eCell and particle manipulation\u003c\/li\u003e\n\u003cli\u003ePrecise multichannel mixing\u003c\/li\u003e\n\u003cli\u003eBacterial biofilm formation on solid surfaces\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eVideos\u003c\/h2\u003e\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/XInRk-Ml8D8\" width=\"560\" height=\"314\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/ueyEBgY0cRs\" width=\"560\" height=\"314\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/6NcwI1TIa9o\" width=\"650\" height=\"364\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e","products":[],"url":"https:\/\/wpiinc.com\/it\/collections\/4u-pressure.oembed","provider":"World Precision Instruments","version":"1.0","type":"link"}