{"title":"Electrophysiology","description":"\u003ch1\u003e\u003cspan\u003eElectrophysiology\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eElectrophysiology helps researchers investigate how electrical signals are generated, transmitted and regulated in cells and tissues. Whether you’re recording from a single cell or studying activity across a neural network, a dependable setup helps you capture and interpret those signals. \u003c\/span\u003e\u003cspan\u003eExplore amplifiers for patch clamp, intracellular and extracellular recordings; stimulators for delivering controlled electrical pulses; and stimulus isolators for delivering stimulation while keeping the stimulation circuit electrically separate from the recording setup. Browse the range to find components for building a new system or expanding an existing one.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"74030-isolated-low-noise-bioamplifer-chassis","title":"Châssis bioamplificateur isolé à faible bruit","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eChâssis pour le bioamplificateur isolé à faible bruit\u003c\/h2\u003e\n\u003cp\u003eDécouvrez ce que vous devez savoir \u003ca href=\"\/fr\/blog\/post\/wpi-s-low-noise-amplifiers-outperform-cheap-imitations\"\u003eavant d’acheter un amplificateur\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eCaractéristiques\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCommandez un châssis et un boîtier d’alimentation (l’article de cette page)\u003c\/li\u003e\n\u003cli\u003eSélectionnez jusqu’à 8 modules (\u003ca href=\"\/fr\/74020-isolated-low-noise-bioamplifier-single-channel-module\"\u003e\u003cstrong\u003eISO-DAM8A\u003c\/strong\u003e \u003c\/a\u003eou \u003ca href=\"\/fr\/bridge8-bridge8-transducer-amplifier-module\"\u003e\u003cstrong\u003eBRIDGE8\u003c\/strong\u003e\u003c\/a\u003e)\u003c\/li\u003e\n\u003cli\u003eCommandez des panneaux pleins (\u003ca href=\"\/fr\/74050-isdb-blank-panels\"\u003e\u003cstrong\u003e74050\u003c\/strong\u003e\u003c\/a\u003e) pour remplir les emplacements vides\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAvantages\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLe châssis accepte une combinaison de bioamplificateurs et d’amplificateurs de transducteurs\u003c\/li\u003e\n\u003cli\u003eNombre de canaux flexible (1–8) permettant une extension\u003c\/li\u003e\n\u003cli\u003eFiltre en peigne ciblant les sources de bruit du réseau électrique\u003c\/li\u003e\n\u003cli\u003eAmplitude de sortie à gain variable\u003c\/li\u003e\n\u003cli\u003eLarge plage de sortie ±10V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAmplification des biopotentiels à l’aide de microélectrodes métalliques\u003c\/li\u003e\n\u003cli\u003ePotentiels de champ de tranches cérébrales\u003c\/li\u003e\n\u003cli\u003eEAG (Électroantennogramme)\u003c\/li\u003e\n\u003cli\u003eERG (Électrorétinogramme)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLe \u003cstrong\u003eISO-DAM8A\u003c\/strong\u003e est un système d’amplificateur DC modulaire compact, standard et montable en rack. Chaque canal est électriquement isolé des autres et de la terre. Aucun courant ne peut circuler depuis les bornes d’entrée et les électrodes. L’instrument est intrinsèquement sûr et ne peut provoquer aucune stimulation électrique ni choc à la préparation. De plus, le bruit de boucle de masse est minimisé.\u003c\/p\u003e\n\u003ch2\u003eFiltres inclus avec l’amplificateur\u003c\/h2\u003e\n\u003cp\u003eLes systèmes peuvent être achetés avec un, deux, trois ou jusqu’à huit modules de préamplificateur ou mélangés avec des modules d’amplificateur de transducteur \u003cstrong\u003eBridge8\u003c\/strong\u003e. Vous pouvez ensuite sélectionner :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUn réglage approprié du filtre passe-bas, du gain et du décalage sur le panneau de l’amplificateur de canal.\u003c\/li\u003e\n\u003cli\u003eUn filtre en peigne ajouté pour réduire les interférences de fréquence secteur.\u003c\/li\u003e\n\u003cli\u003eUn préamplificateur de tête optionnel (gain 10x) permettant un enregistrement extracellulaire (DC) à faible bruit avec le \u003cstrong\u003eIso-DAM8A\u003c\/strong\u003e et offrant une bande passante plus large qu’un câble blindé de même longueur.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLa configuration amplificateur et tête \u003cstrong\u003eIso-DAM8A\u003c\/strong\u003e est parfaitement adaptée à l’utilisation avec nos \u003ca href=\"\/fr\/products\/supplies-parts-accessories\/electrodes\/electrodes\"\u003emicroélectrodes métalliques\u003c\/a\u003e et peut être facilement configurée pour de nombreuses applications. Chaque canal d’amplificateur dispose d’un connecteur coaxial (BNC) situé sur le panneau arrière.\u003c\/p\u003e\n\u003ch2\u003eConfigurer votre système ISDB\u003c\/h2\u003e\n\u003cp\u003eLe châssis ISDB (\u003ca href=\"\/fr\/74030-isolated-low-noise-bioamplifer-chassis\"\u003e\u003cstrong\u003e74030\u003c\/strong\u003e\u003c\/a\u003e) peut accueillir jusqu’à huit modules et comprend une alimentation. Vous pouvez inclure n’importe quelle combinaison de modules d’amplificateur de transducteur \u003ca href=\"\/fr\/bridge8-bridge8-transducer-amplifier-module\"\u003e\u003cstrong\u003eBRIDGE8\u003c\/strong\u003e\u003c\/a\u003e ou de modules mono-canal ISO-DAM8A (\u003ca href=\"\/fr\/74020-isolated-low-noise-bioamplifier-single-channel-module\"\u003e\u003cstrong\u003e74020\u003c\/strong\u003e\u003c\/a\u003e). Si vous choisissez moins de huit modules, vous devez commander les panneaux pleins ISDB (\u003ca href=\"\/fr\/74050-isdb-blank-panels\"\u003e\u003cstrong\u003e74050\u003c\/strong\u003e\u003c\/a\u003e) pour remplir les emplacements vides du châssis. Les bioamplificateurs ISO-DAM8A incluent un connecteur DIN 8 broches avec câble blindé non terminé de 5 pieds. Veuillez spécifier la tension secteur lors de la commande.\u003c\/p\u003e\n\u003cp\u003eLors de la configuration de votre système ISDB :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCommandez un châssis et un boîtier d’alimentation (\u003ca href=\"\/fr\/74030-isolated-low-noise-bioamplifer-chassis\"\u003e\u003cstrong\u003e74030\u003c\/strong\u003e\u003c\/a\u003e)\u003c\/li\u003e\n\u003cli\u003eSélectionnez jusqu’à 8 modules (\u003ca href=\"\/fr\/74020-isolated-low-noise-bioamplifier-single-channel-module\"\u003e\u003cstrong\u003eISO-DAM8A\u003c\/strong\u003e \u003c\/a\u003eou \u003ca href=\"\/fr\/bridge8-bridge8-transducer-amplifier-module\"\u003e\u003cstrong\u003eBRIDGE8\u003c\/strong\u003e\u003c\/a\u003e)\u003c\/li\u003e\n\u003cli\u003eCommandez des panneaux pleins (\u003ca href=\"\/fr\/74050-isdb-blank-panels\"\u003e\u003cstrong\u003e74050\u003c\/strong\u003e\u003c\/a\u003e) pour remplir les emplacements vides\u003c\/li\u003e\n\u003cli\u003eISO-DAM8A \u003ca href=\"\/fr\/74020-isolated-low-noise-bioamplifier-single-channel-module\"\u003e\u003cstrong\u003e74020\u003c\/strong\u003e \u003c\/a\u003eest un amplificateur DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSystème complet d’amplificateur huit canaux avec châssis 74030 montrant huit modules \u003ca href=\"\/fr\/74020-isolated-low-noise-bioamplifier-single-channel-module\"\u003e74020\u003c\/a\u003e (ISODAM8A) installés\u003cbr\u003e*Disponible également pour modules d’amplificateur de transducteur BRIDGE8 et panneaux pleins (74050).\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/Iso-DAM8a-full_7f8b430e-57f7-43a1-a0bb-cc0a58b4b19f.jpg?v=1765943236\" alt=\"Iso-DAM8a\" width=\"500\" height=\"205\"\u003e\u003c\/p\u003e\n\u003cp\u003eLa photo illustre un système complet d’amplificateur et montre le châssis 74030 avec huit modules amplificateurs ISO-DAM8A (74020).\u003c\/p\u003e\n\u003cp\u003e*Les modules sont vendus séparément.  \u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr bgcolor=\"#e4e4e4\"\u003e\n\u003ctd\u003eSource d’alimentation\u003c\/td\u003e\n\u003ctd\u003eAdaptateur secteur 110-120V\/60Hz ou 220-240V\/50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions du boîtier\u003c\/td\u003e\n\u003ctd\u003e7 x 17 x 9,2 pouces (18 x 43 x 23 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e4e4e4\"\u003e\n\u003ctd\u003ePoids à l’expédition\u003c\/td\u003e\n\u003ctd\u003e10–21 lb (4,5–9,5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42265635651674,"sku":"74030","price":2800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/isdb_e0309281-674f-41e9-b88a-cedf625e29be.jpg?v=1766393128"},{"product_id":"var-2273-constant-current-stimulus-isolator","title":"Isolateur de stimulus à courant constant","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eImpulsions bipolaires automatisées pour une charge nette nulle sur les préparations biologiques\u003c\/h2\u003e\n\u003ch2\u003eCaractéristiques\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCourant constant\u003c\/li\u003e\n\u003cli\u003eModes de stimulation unipolaire et bipolaire\u003c\/li\u003e\n\u003cli\u003eAlarme intégrée de non-conformité\u003c\/li\u003e\n\u003cli\u003eEntrée optiquement isolée\u003c\/li\u003e\n\u003cli\u003eDéclenchement TTL standard\u003c\/li\u003e\n\u003cli\u003eMode test CC\u003c\/li\u003e\n\u003cli\u003eAlimenté par des piles alcalines 9 V ou rechargeables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOptions\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #0081c2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eRéf. #\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eDescription\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eType de batterie\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eComprend le chargeur\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eA365RC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA365R avec un chargeur de batterie A362\u003c\/td\u003e\n\u003ctd\u003eBatterie rechargeable\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eOui\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSYS-A365R\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIsolateur haute tension, bipolaire\u003c\/td\u003e\n\u003ctd\u003eBatterie rechargeable\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eNon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSYS-A365D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIsolateur haute tension, bipolaire\u003c\/td\u003e\n\u003ctd\u003ePiles alcalines\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e_\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eAvantages\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLa tension de conformité est de 100 V ou plus\u003c\/li\u003e\n\u003cli\u003eLe mode bipolaire génère automatiquement des impulsions positives et négatives alternées à partir d'une entrée TTL\u003c\/li\u003e\n\u003cli\u003eLe mode test simplifie la vérification des performances\u003c\/li\u003e\n\u003cli\u003eL'isolation optique améliore la sécurité de la préparation et réduit la susceptibilité au bruit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eÉlectrophysiologie\u003c\/li\u003e\n\u003cli\u003eStimulation de tranches cérébrales\u003c\/li\u003e\n\u003cli\u003e\nStimulation cérébrale et du SNC \u003cem\u003ein vivo\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eActivé par des commandes logiques conventionnelles, Modèle \u003cstrong\u003eA365\u003c\/strong\u003e peuvent être commandées par n'importe quel générateur d'impulsions, stimulateur ou sortie d'ordinateur avec impulsions bipolaires automatisées pour une charge nette nulle sur les préparations biologiques.\u003c\/p\u003e\n\u003ch2\u003eAlarmes sonores à double tonalité\u003c\/h2\u003e\n\u003cp\u003eUn signal sonore retentit lorsqu'un circuit d'électrode ouvert est détecté ou lorsque la conformité du système est atteinte. Un second signal sonore optionnel retentit lorsqu'un signal est appliqué à l'entrée. Un interrupteur de test est également prévu pour vérifier la charge de la batterie.\u003c\/p\u003e\n\u003ch2\u003eFourniture de courant jusqu'à 10 mA à plus de 100 V\u003c\/h2\u003e\n\u003cp\u003eLes courants de stimulation sont réglés à l'aide d'un bouton de contrôle à trois chiffres et d'un commutateur de plage à trois positions. Le courant de sortie suit les réglages de contrôle à mieux que 1 %. Le courant de sortie est indépendant de la charge, et la tension suffisante pour pousser le courant désiré à travers la charge est automatiquement développée, sous réserve uniquement des limites de conformité. Modèle \u003cstrong\u003eA360LA\u003c\/strong\u003e produit jusqu'à 10 mA de courant, dans trois plages, avec une conformité supérieure à 100 V.\u003c\/p\u003e\n\u003ch2\u003ePolarité de sortie bipolaire\u003c\/h2\u003e\n\u003cp\u003eLa polarité de sortie est déterminée par un interrupteur-poussoir sur le panneau avant. Le courant bipolaire est basculé par la forme d'onde de commande, définissant les impulsions alternées comme positives ou négatives.\u003c\/p\u003e\n\u003ch2\u003eAlimentation\u003c\/h2\u003e\n\u003cp\u003eCet\u003cstrong\u003e\u003ca href=\"\/fr\/index.php?src=directory\u0026amp;view=products\u0026amp;srctype=detail\u0026amp;refno=2273\u0026amp;category=Physiology\"\u003e \u003c\/a\u003eA365RC\u003c\/strong\u003e Isolateur de Stimulus comprend à la fois l'isolateur de stimulus \u003cstrong\u003eA365R\u003c\/strong\u003e et le chargeur de batterie \u003cstrong\u003eA362\u003c\/strong\u003e. Le \u003cstrong\u003eA365R\u003c\/strong\u003e rechargeable est fourni avec un ensemble de batteries nickel-hydrure métallique. Le \u003ca href=\"\/fr\/sys-a362-a362-battery-charger\"\u003e\u003cstrong\u003eChargeur de batterie A362\u003c\/strong\u003e\u003c\/a\u003e est requis avec le \u003cstrong\u003eA365R\u003c\/strong\u003e. \u003c\/p\u003e\n\u003cp\u003e REMARQUE : Non destiné à un usage humain.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/A365_IMs.pdf\" target=\"_self\"\u003eManuel d'instructions A365\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:specifications --\u003e\n\u003ctable cellpadding=\"2\" cellspacing=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFORME D'ONDE DE SORTIE\u003c\/td\u003e\n\u003ctd\u003eCC ou impulsion de courant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003ePLAGES DE COURANT DE SORTIE\u003c\/td\u003e\n\u003ctd\u003e0,1, 1,0 et 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eERREUR D'AMPLITUDE DU COURANT\u003c\/td\u003e\n\u003ctd\u003e0,5 % de l'échelle complète, max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eRÉSOLUTION ACTUELLE\u003c\/td\u003e\n\u003ctd\u003e0.1 % de l’échelle complète, typique\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEXCURSION DE TENSION DE CHARGE DE SORTIE (CONFORMITÉ)\u003c\/td\u003e\n\u003ctd\u003e100 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eSEUIL DE COMMANDE EXTERNE\u003c\/td\u003e\n\u003ctd\u003e5 V à 3 mA, min. 10 V, max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEUIL DE DÉCLENCHEMENT\u003c\/td\u003e\n\u003ctd\u003e2.0 V à 0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOLARITÉ DE SORTIE\u003c\/td\u003e\n\u003ctd\u003eRéversible, interrupteur manuel ou automatique\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eTEMPS DE MONTÉE ET DÉLAI DU COURANT\u003c\/td\u003e\n\u003ctd\u003e6 μs, typique (charge 1 KΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEMPS DE CHUTE ET DÉLAI DU COURANT\u003c\/td\u003e\n\u003ctd\u003e10 μs, typique (charge 1 KΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eRÉSISTANCE DE SORTIE VERS LA MASSE\u003c\/td\u003e\n\u003ctd\u003e10\u003csup\u003e12 \u003c\/sup\u003eΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOPTOCOUPLEUR\u003c\/td\u003e\n\u003ctd\u003e2500 V, tension de claquage minimale nominale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eALIMENTATION : Modèle A365D (pile sèche)\u003c\/td\u003e\n\u003ctd\u003e16 piles alcalines 9 V incluses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eALIMENTATION : Modèle A365R (rechargeable)\u003c\/td\u003e\n\u003ctd\u003e16 piles NiMH rechargeables 9 V incluses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eDIMENSIONS\u003c\/td\u003e\n\u003ctd\u003e8.5 x 3.5 x 5 po (22 x 9 x 12 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOIDS D’EXPÉDITION\u003c\/td\u003e\n\u003ctd\u003e4 lb. (1.8 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cb\u003eYavich, L., Tanila, H., Vepsäläinen, S., \u0026amp; Jäkälä, P. (n.d.).\u003c\/b\u003e Neurobiologie des maladies Rôle de la ␣-synucléine dans le recrutement présynaptique de la dopamine. \u003ca href=\"https:\/\/doi.org\/10.1523\/JNEUROSCI.2559-04.2004\"\u003ehttps:\/\/doi.org\/10.1523\/JNEUROSCI.2559-04.2004\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIremonger, K. J., Anderson, T. R., Hu, B., \u0026amp; Kiss, Z. H. T. (n.d.).\u003c\/b\u003e Mécanismes cellulaires empêchant l’activation soutenue du cortex lors d’une stimulation sous-corticale à haute fréquence. \u003ca href=\"https:\/\/doi.org\/10.1152\/jn.00105.2006\"\u003ehttps:\/\/doi.org\/10.1152\/jn.00105.2006\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eRowland, N. C., \u0026amp; Jaeger, D. (n.d.).\u003c\/b\u003e Les réponses à la stimulation tactile dans les neurones du noyau cérébelleux profond résultent d’une activation récurrente dans plusieurs voies. \u003ca href=\"https:\/\/doi.org\/10.1152\/jn.01100.2007\"\u003ehttps:\/\/doi.org\/10.1152\/jn.01100.2007\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eD ’ambrosio, R., Gordon, D. S., Winn, H. R., ’ambrosio, D., Raimondo, D. S., Gordon, H., \u0026amp; Richard, W. (n.d.).\u003c\/b\u003e Rôle différentiel du canal KIR et de la pompe Na ϩ \/K ϩ dans la régulation du K ϩ extracellulaire dans l’hippocampe de rat. \u003ca href=\"https:\/\/doi.org\/10.1152\/jn.00240.2001\"\u003ehttps:\/\/doi.org\/10.1152\/jn.00240.2001\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHuda, R., Mccrimmon, D. R., \u0026amp; Martina, M. (n.d.).\u003c\/b\u003e La modulation du pH des transporteurs gliaux de glutamate régule la transmission synaptique dans le noyau du tractus solitaire.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eChen, Y., Beffert, U., Ertunc, M., Tang, T.-S., Kavalali, E. T., Bezprozvanny, I., \u0026amp; Herz, J. (n.d.).\u003c\/b\u003e Développement\/Plasticité\/Réparation Reelin module l’activité des récepteurs NMDA dans les neurones corticaux. \u003ca href=\"https:\/\/doi.org\/10.1523\/JNEUROSCI.1951-05.2005\"\u003ehttps:\/\/doi.org\/10.1523\/JNEUROSCI.1951-05.2005\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eD ’ambrosio, R., Wenzel, J., Schwartzkroin, P. A., Mckhann Ii, G. M., \u0026amp; Janigro, D. (n.d.).\u003c\/b\u003e Spécialisation fonctionnelle et ségrégation topographique des astrocytes hippocampiques.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eD ’ambrosio, R., Maris, D. O., Grady, M. S., Winn, H. R., \u0026amp; Janigro, D. (n.d.).\u003c\/b\u003e Homéostasie altérée du K ؉ et propriétés électrophysiologiques modifiées des glies hippocampiques post-traumatiques.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eJi, H., \u0026amp; Shepard, P. D. (n.d.).\u003c\/b\u003e Comportement\/Systèmes\/Cognitif La stimulation de l’habénula latérale inhibe les neurones dopaminergiques du mésencéphale du rat via un mécanisme médié par le récepteur GABA A. \u003ca href=\"https:\/\/doi.org\/10.1523\/JNEUROSCI.0958-07.2007\"\u003ehttps:\/\/doi.org\/10.1523\/JNEUROSCI.0958-07.2007\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eLee, E., Hong, J., Park, Y.-G., Chae, S., Kim, Y., \u0026amp; Kim, D. (2015).\u003c\/b\u003e L’activité corticale du cerveau gauche module les effets du stress sur le comportement social. \u003ci\u003eScientific Reports\u003c\/i\u003e, \u003ci\u003e5\u003c\/i\u003e, 13342. \u003ca href=\"https:\/\/doi.org\/10.1038\/srep13342\"\u003ehttps:\/\/doi.org\/10.1038\/srep13342\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eGindrat, A.-D., Quairiaux, C., Britz, J., Brunet, D., Lanz, F., Michel, C. M., \u0026amp; Rouiller, E. M. (2015).\u003c\/b\u003e Cartographie EEG complète du cuir chevelu des potentiels évoqués somatosensoriels chez le macaque. \u003ci\u003eBrain Structure \u0026amp; Function\u003c\/i\u003e, \u003ci\u003e220\u003c\/i\u003e(4), 2121–2142. \u003ca href=\"https:\/\/doi.org\/10.1007\/s00429-014-0776-y\"\u003ehttps:\/\/doi.org\/10.1007\/s00429-014-0776-y\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAvila, I., \u0026amp; Lin, S.-C. (2014).\u003c\/b\u003e Le signal de saillance motivationnelle dans le prosencéphale basal est associé à une vitesse de décision plus rapide et plus précise. \u003ci\u003ePLoS Biology\u003c\/i\u003e, \u003ci\u003e12\u003c\/i\u003e(3), e1001811. \u003ca href=\"https:\/\/doi.org\/10.1371\/journal.pbio.1001811\"\u003ehttps:\/\/doi.org\/10.1371\/journal.pbio.1001811\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNguyen, D. P., \u0026amp; Lin, S.-C. (2014).\u003c\/b\u003e Un potentiel évoqué lié à un événement dans le cortex frontal piloté par le prosencéphale basal. \u003ci\u003eELife\u003c\/i\u003e, \u003ci\u003e3\u003c\/i\u003e, e02148. Consulté sur \u003ca rel=\"noopener\" href=\"https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC3974155\/\" target=\"_blank\"\u003ehttps:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC3974155\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHerrera, C., Directores, R., Panetsos, F., Carlos, P., \u0026amp; Trueba, A. (2014).\u003c\/b\u003e THÈSE DE DOCTORAT Effets de la stimulation artificielle d’un nerf périphérique sectionné sur la voie somatosensorielle désafférentée du rat.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eYounce, J. R., Albaugh, D. L., \u0026amp; Shih, Y.-Y. I. (2014).\u003c\/b\u003e Stimulation cérébrale profonde avec IRMf simultanée chez les rongeurs. \u003ci\u003eJournal of Visualized Experiments\u003c\/i\u003e, (84), e51271–e51271. \u003ca href=\"https:\/\/doi.org\/10.3791\/51271\"\u003ehttps:\/\/doi.org\/10.3791\/51271\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOulad Ben Taib, N., \u0026amp; Manto, M. (2013).\u003c\/b\u003e Trains de stimulation DC épidurale du cervelet modulant l’excitabilité corticomotrice. \u003ci\u003eNeural Plasticity\u003c\/i\u003e, \u003ci\u003e2013\u003c\/i\u003e(10), 1–12. \u003ca href=\"https:\/\/doi.org\/10.1155\/2013\/613197\"\u003ehttps:\/\/doi.org\/10.1155\/2013\/613197\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSyvänen, S., Russmann, V., Verbeek, J., Eriksson, J., Labots, M., Zellinger, C., … Potschka, H. (2013).\u003c\/b\u003e Imagerie PET au [11C]quinidine et [11C]laniquidar dans un modèle chronique d’épilepsie chez le rongeur : impact de l’épilepsie et de la réponse aux médicaments. \u003ci\u003eNuclear Medicine and Biology\u003c\/i\u003e, \u003ci\u003e40\u003c\/i\u003e(6), 764–775. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.nucmedbio.2013.05.008\"\u003ehttps:\/\/doi.org\/10.1016\/j.nucmedbio.2013.05.008\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSchroder, E. A., Lefta, M., Zhang, X., Bartos, D. C., Feng, H.-Z., Zhao, Y., … Delisle, B. P. (2013).\u003c\/b\u003e L'horloge moléculaire du cardiomyocyte, la régulation de Scn5a, et la susceptibilité aux arythmies. \u003ci\u003eAmerican Journal of Physiology. Cell Physiology\u003c\/i\u003e, \u003ci\u003e304\u003c\/i\u003e(10), C954-65. \u003ca href=\"https:\/\/doi.org\/10.1152\/ajpcell.00383.2012\"\u003ehttps:\/\/doi.org\/10.1152\/ajpcell.00383.2012\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSchmuckermair, C., Gaburro, S., Sah, A., Landgraf, R., Sartori, S. B., \u0026amp; Singewald, N. (2013).\u003c\/b\u003e Effets comportementaux et neurobiologiques de la stimulation cérébrale profonde dans un modèle murin d'anxiété élevée et de comportement dépressif. \u003ci\u003eNeuropsychopharmacology : Official Publication of the American College of Neuropsychopharmacology\u003c\/i\u003e, \u003ci\u003e38\u003c\/i\u003e(7), 1234–1244. \u003ca href=\"https:\/\/doi.org\/10.1038\/npp.2013.21\"\u003ehttps:\/\/doi.org\/10.1038\/npp.2013.21\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDalby-Brown, W., Jessen, C., Hougaard, C., Jensen, M. L., Jacobsen, T. A., Nielsen, K. S., … Jørgensen, S. (2013).\u003c\/b\u003e Caractérisation d'un nouveau modulateur positif à haute puissance des canaux Kv7. \u003ci\u003eEuropean Journal of Pharmacology\u003c\/i\u003e, \u003ci\u003e709\u003c\/i\u003e(1–3), 52–63. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.ejphar.2013.03.039\"\u003ehttps:\/\/doi.org\/10.1016\/j.ejphar.2013.03.039\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eLicko, T., Seeger, N., Zellinger, C., Russmann, V., Matagne, A., \u0026amp; Potschka, H. (2013). \u003c\/b\u003eLe traitement par lacosamide après un status epilepticus atténue la perte neuronale et les altérations de la neurogenèse hippocampique dans un modèle électrique de status epilepticus chez le rat. \u003ci\u003eEpilepsia\u003c\/i\u003e, \u003ci\u003e54\u003c\/i\u003e(7), 1176–1185. \u003ca href=\"https:\/\/doi.org\/10.1111\/epi.12196\"\u003ehttps:\/\/doi.org\/10.1111\/epi.12196\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAtherton, J. F., Menard, A., Urbain, N., \u0026amp; Bevan, M. D. (2013).\u003c\/b\u003e Dépression à court terme de la transmission synaptique du globus pallidus externe au noyau sous-thalamique et implications pour le modelage de l'activité sous-thalamique. \u003ci\u003eThe Journal of Neuroscience : The Official Journal of the Society for Neuroscience\u003c\/i\u003e, \u003ci\u003e33\u003c\/i\u003e(17), 7130–7144. \u003ca href=\"https:\/\/doi.org\/10.1523\/JNEUROSCI.3576-12.2013\"\u003ehttps:\/\/doi.org\/10.1523\/JNEUROSCI.3576-12.2013\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSaha, D., Leong, K., Katta, N., \u0026amp; Raman, B. (2013).\u003c\/b\u003e Méthodes d'enregistrement multi-unités pour caractériser l'activité neuronale dans les circuits olfactifs de la sauterelle (\u0026amp;lt;em\u0026amp;gt;Schistocerca Americana\u0026amp;lt;\/em\u0026amp;gt;). \u003ci\u003eJournal of Visualized Experiments\u003c\/i\u003e, (71), e50139–e50139. \u003ca href=\"https:\/\/doi.org\/10.3791\/50139\"\u003ehttps:\/\/doi.org\/10.3791\/50139\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHuda, R., McCrimmon, D. R., \u0026amp; Martina, M. (2013).\u003c\/b\u003e La modulation du pH des transporteurs gliaux de glutamate régule la transmission synaptique dans le noyau du tractus solitaire. \u003ci\u003eJournal of Neurophysiology\u003c\/i\u003e, \u003ci\u003e110\u003c\/i\u003e(2), 368–377. \u003ca href=\"https:\/\/doi.org\/10.1152\/jn.01074.2012\"\u003ehttps:\/\/doi.org\/10.1152\/jn.01074.2012\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSonner, P. M., \u0026amp; Ladle, D. R. (2013).\u003c\/b\u003e Développement postnatal précoce de l’inhibition présynaptique GABAergique des connexions afférentes proprioceptives Ia dans la moelle épinière de souris. \u003ci\u003eJournal of Neurophysiology\u003c\/i\u003e, \u003ci\u003e109\u003c\/i\u003e(8), 2118–2128. \u003ca href=\"https:\/\/doi.org\/10.1152\/jn.00783.2012\"\u003ehttps:\/\/doi.org\/10.1152\/jn.00783.2012\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eZhu, Z., Sierra, A., Burnett, C. M.-L. L., Chen, B., Subbotina, E., Koganti, S. R. K., … Zingman, L. V. (2013).\u003c\/b\u003e Les canaux potassiques ATP-sensibles sarcolemmaux modulent la fonction musculaire squelettique sous des charges de travail à faible intensité. \u003ci\u003eThe Journal of General Physiology\u003c\/i\u003e, \u003ci\u003e143\u003c\/i\u003e(1), 119–134. \u003ca href=\"https:\/\/doi.org\/10.1085\/jgp.201311063\"\u003ehttps:\/\/doi.org\/10.1085\/jgp.201311063\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eBrenowitz, S. D., \u0026amp; Regehr, W. G. (2012).\u003c\/b\u003e Imagerie présynaptique des fibres de projection par injection in vivo d’indicateurs calciques conjugués au dextran. \u003ci\u003eCold Spring Harbor Protocols\u003c\/i\u003e, \u003ci\u003e2012\u003c\/i\u003e(4), 465–471. \u003ca href=\"https:\/\/doi.org\/10.1101\/pdb.prot068551\"\u003ehttps:\/\/doi.org\/10.1101\/pdb.prot068551\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eLi, W., Janardhan, A. H., Fedorov, V. V, Sha, Q., Schuessler, R. B., \u0026amp; Efimov, I. R. (2011).\u003c\/b\u003e La thérapie de défibrillation atriale multistade à basse énergie termine la fibrillation atriale avec moins d’énergie qu’un choc unique. \u003ci\u003eCirculation. Arrhythmia and Electrophysiology\u003c\/i\u003e, \u003ci\u003e4\u003c\/i\u003e(6), 917–925. \u003ca href=\"https:\/\/doi.org\/10.1161\/CIRCEP.111.965830\"\u003ehttps:\/\/doi.org\/10.1161\/CIRCEP.111.965830\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eMathis, D. M., Furman, J. L., \u0026amp; Norris, C. M. (2011).\u003c\/b\u003e Préparation de tranches aiguës d’hippocampe de rats et de souris transgéniques pour l’étude des altérations synaptiques durant le vieillissement et la pathologie amyloïde. \u003ci\u003eJournal of Visualized Experiments\u003c\/i\u003e, (49), e2330–e2330. \u003ca href=\"https:\/\/doi.org\/10.3791\/2330\"\u003ehttps:\/\/doi.org\/10.3791\/2330\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eManto, M. U., Hampe, C. S., Rogemond, V., \u0026amp; Honnorat, J. (2011).\u003c\/b\u003e Implications respectives des anticorps contre la glutamate décarboxylase dans le syndrome de la personne raide et l’ataxie cérébelleuse. \u003ci\u003eOrphanet Journal of Rare Diseases\u003c\/i\u003e, \u003ci\u003e6\u003c\/i\u003e(1), 3. \u003ca href=\"https:\/\/doi.org\/10.1186\/1750-1172-6-3\"\u003ehttps:\/\/doi.org\/10.1186\/1750-1172-6-3\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eKim, J., Woo, J., Park, Y.-G., Chae, S., Jo, S., Choi, J. W., … Kim, D. (2011).\u003c\/b\u003e Les canaux calciques T-type thalamiques médiatisent les dysfonctionnements du lobe frontal causés par un dommage de type hypoxique dans le cortex préfrontal. \u003ci\u003eThe Journal of Neuroscience : The Official Journal of the Society for Neuroscience\u003c\/i\u003e, \u003ci\u003e31\u003c\/i\u003e(11), 4063–4073. \u003ca href=\"https:\/\/doi.org\/10.1523\/JNEUROSCI.4493-10.2011\"\u003ehttps:\/\/doi.org\/10.1523\/JNEUROSCI.4493-10.2011\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSeo, J. H., Jang, I. K., Kim, H., Yang, M. S., Lee, J. E., Kim, H. E., … Cho, S.-R. (2011).\u003c\/b\u003e Immunomodulation précoce par des cellules souches mésenchymateuses transplantées par voie intraveineuse favorise la récupération fonctionnelle chez des rats avec une lésion de la moelle épinière. \u003ci\u003eCell Medicine\u003c\/i\u003e, \u003ci\u003e2\u003c\/i\u003e(2), 55–67. \u003ca href=\"https:\/\/doi.org\/10.3727\/215517911X582788\"\u003ehttps:\/\/doi.org\/10.3727\/215517911X582788\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePelkonen, A., Hiltunen, M., Kiianmaa, K., \u0026amp; Yavich, L. (2010).\u003c\/b\u003e Débordement de dopamine stimulé et expression d'alpha-synucléine dans le noyau accumbens core distinguent les rats sélectionnés pour une préférence différentielle à l'éthanol. \u003ci\u003eJournal of Neurochemistry\u003c\/i\u003e, \u003ci\u003e114\u003c\/i\u003e(4), 1168–1176. \u003ca href=\"https:\/\/doi.org\/10.1111\/j.1471-4159.2010.06844.x\"\u003ehttps:\/\/doi.org\/10.1111\/j.1471-4159.2010.06844.x\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFoust, A. J., Schei, J. L., Rojas, M. J., \u0026amp; Rector, D. M. (2008).\u003c\/b\u003e Analyse du bruit in vitro et in vivo pour l'enregistrement neural optique. \u003ci\u003eJournal of Biomedical Optics\u003c\/i\u003e, \u003ci\u003e13\u003c\/i\u003e(4), 044038. \u003ca href=\"https:\/\/doi.org\/10.1117\/1.2952295\"\u003ehttps:\/\/doi.org\/10.1117\/1.2952295\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSchei, J. L., McCluskey, M. D., Foust, A. J., Yao, X.-C., \u0026amp; Rector, D. M. (2008). \u003c\/b\u003ePropagation du potentiel d'action imagée avec une résolution temporelle élevée par microscopie vidéo proche infrarouge et lumière polarisée. \u003ci\u003eNeuroImage\u003c\/i\u003e, \u003ci\u003e40\u003c\/i\u003e(3), 1034–1043. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.neuroimage.2007.12.055\"\u003ehttps:\/\/doi.org\/10.1016\/j.neuroimage.2007.12.055\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFoust, A. J., \u0026amp; Rector, D. M. (2007). \u003c\/b\u003eDémêler optiquement le gonflement neural et la dépolarisation. \u003ci\u003eNeuroscience\u003c\/i\u003e, \u003ci\u003e145\u003c\/i\u003e(3), 887–899. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.neuroscience.2006.12.068\"\u003ehttps:\/\/doi.org\/10.1016\/j.neuroscience.2006.12.068\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eJi, H., \u0026amp; Shepard, P. D. (2007).\u003c\/b\u003e La stimulation de l'habénula latérale inhibe les neurones dopaminergiques du mésencéphale chez le rat via un mécanisme médié par les récepteurs GABA(A). \u003ci\u003eThe Journal of Neuroscience : The Official Journal of the Society for Neuroscience\u003c\/i\u003e, \u003ci\u003e27\u003c\/i\u003e(26), 6923–6930. \u003ca href=\"https:\/\/doi.org\/10.1523\/JNEUROSCI.0958-07.2007\"\u003ehttps:\/\/doi.org\/10.1523\/JNEUROSCI.0958-07.2007\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eLee, B. H., Lee, K. H., Yoon, D. H., Kim, U. J., Hwang, Y. S., Park, S. K., … Jahng, T. (2005).\u003c\/b\u003e Effets de la méthylprednisolone sur la conduction neuronale des potentiels moteurs évoqués chez des rats avec lésion de la moelle épinière. \u003ci\u003eJournal of Korean Medical Science\u003c\/i\u003e, \u003ci\u003e20\u003c\/i\u003e(1), 132–138. \u003ca href=\"https:\/\/doi.org\/10.3346\/jkms.2005.20.1.132\"\u003ehttps:\/\/doi.org\/10.3346\/jkms.2005.20.1.132\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAnderson, T., Hu, B., Pittman, Q., \u0026amp; Kiss, Z. H. T. (2004).\u003c\/b\u003e Mécanismes de la stimulation cérébrale profonde : une étude intracellulaire dans le thalamus de rat. \u003ci\u003eThe Journal of Physiology\u003c\/i\u003e, \u003ci\u003e559\u003c\/i\u003e(1), 301–313. \u003ca href=\"https:\/\/doi.org\/10.1113\/jphysiol.2004.064998\"\u003ehttps:\/\/doi.org\/10.1113\/jphysiol.2004.064998\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSokolow, S., Manto, M., Gailly, P., Molgó, J., Vandebrouck, C., Vanderwinden, J.-M., … Schurmans, S. (2004).\u003c\/b\u003e Transmission neuromusculaire altérée et nécrose des fibres musculaires squelettiques chez des souris dépourvues de l’échangeur Na\/Ca 3. \u003ci\u003eJournal of Clinical Investigation\u003c\/i\u003e, \u003ci\u003e113\u003c\/i\u003e(2), 265–273. \u003ca href=\"https:\/\/doi.org\/10.1172\/JCI18688\"\u003ehttps:\/\/doi.org\/10.1172\/JCI18688\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eD’Ambrosio, R., Fairbanks, J. P., Fender, J. S., Born, D. E., Doyle, D. L., \u0026amp; Miller, J. W. (2004). \u003c\/b\u003eÉpilepsie post-traumatique après traumatisme par percussion liquide chez le rat. \u003ci\u003eBrain : A Journal of Neurology\u003c\/i\u003e, \u003ci\u003e127\u003c\/i\u003e(Pt 2), 304–314. \u003ca href=\"https:\/\/doi.org\/10.1093\/brain\/awh038\"\u003ehttps:\/\/doi.org\/10.1093\/brain\/awh038\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eShaw, B. K., \u0026amp; Kennedy, G. G. (2002).\u003c\/b\u003e Preuves de différences interespèces dans le schéma de distribution des récepteurs aux androgènes en relation avec des différences comportementales dépendantes des androgènes. \u003ci\u003eJournal of Neurobiology\u003c\/i\u003e, \u003ci\u003e52\u003c\/i\u003e(3), 203–220. \u003ca href=\"https:\/\/doi.org\/10.1002\/neu.10079\"\u003ehttps:\/\/doi.org\/10.1002\/neu.10079\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eYavich, L., \u0026amp; Tiihonen, J. (2000).\u003c\/b\u003e L’éthanol module la libération de dopamine évoquée dans le noyau accumbens de la souris : dépendance au stress social et à la dose. \u003ci\u003eEuropean Journal of Pharmacology\u003c\/i\u003e, \u003ci\u003e401\u003c\/i\u003e(3), 365–373. Consulté sur \u003ca href=\"http:\/\/www.safetylit.org\/citations\/index.php?fuseaction=citations.viewdetails\u0026amp;citationIds%5B%5D=citjournalarticle_271069_38\"\u003ehttp:\/\/www.safetylit.org\/citations\/index.php?fuseaction=citations.viewdetails\u0026amp;citationIds%5B%5D=citjournalarticle_271069_38\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eKnisley, S. B., Trayanova, N., \u0026amp; Aguel, F. (1999).\u003c\/b\u003e Rôles du champ électrique et de la structure des fibres dans la stimulation électrique cardiaque. \u003ci\u003eBiophysical Journal\u003c\/i\u003e, \u003ci\u003e77\u003c\/i\u003e(3), 1404–1417. \u003ca href=\"https:\/\/doi.org\/10.1016\/S0006-3495(99)76989-4\"\u003ehttps:\/\/doi.org\/10.1016\/S0006-3495(99)76989-4\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Alcalin","offer_id":42266068615258,"sku":"SYS-A365D","price":1800.0,"currency_code":"USD","in_stock":true},{"title":"Rechargeable","offer_id":42266068582490,"sku":"SYS-A365R","price":2300.0,"currency_code":"USD","in_stock":true},{"title":"Rechargeable avec Chargeur","offer_id":42266068648026,"sku":"A365RC","price":2700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/a365_1_fc747f0d-6742-4e53-b046-ddaebb5c1dcc.jpg?v=1766396620"},{"product_id":"sys-a382-battery-charger","title":"Chargeur de batterie","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaractéristiques\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eChargeur innovant en 3 étapes utilisant des charges rapides, moyennes et d'entretien\u003c\/li\u003e\r\n\u003cli\u003eCharge à un courant sûr et faible, prolongeant considérablement la durée de vie de la batterie\u003c\/li\u003e\r\n\u003cli\u003eÀ utiliser uniquement avec les batteries dans l'isolateur de stimulus A385\u003c\/li\u003e\r\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/A382-IM.pdf\"\u003eManuel d'instructions A382\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ePUISSANCE\u003c\/td\u003e\r\n\u003ctd\u003e95-135 V ou 220-240 V, 50\/60 Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eDIMENSIONS\u003c\/td\u003e\r\n\u003ctd\u003e8,5 x 3,5 x 5 po (22 x 9 x 12 cm)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ePOIDS D'EXPÉDITION\u003c\/td\u003e\r\n\u003ctd\u003e5 lb (2,3 kg)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266239172698,"sku":"SYS-A382","price":975.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/a382-front_e2948864-4042-4264-8ad1-ce6b91ddd557.jpg?v=1766399584"},{"product_id":"var-su-dpatch-dpatch-system","title":"Système dPatch","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eOptions\u003c\/h2\u003e\n\u003ctable width=\"100%\" style=\"width: 100%;\" class=\"product-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 15.4776%;\"\u003e\u003cstrong\u003eCode de commande\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 38.4522%;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 46.0701%;\"\u003e\u003cstrong\u003eDétails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15.4776%;\"\u003eSU-DPATCH\u003c\/td\u003e\n\u003ctd style=\"width: 38.4522%;\"\u003eSystème dPatch avec un headstage et préamplificateur\u003c\/td\u003e\n\u003ctd style=\"width: 46.0701%;\"\u003eComprend : système dPatch avec un headstage et préamplificateur, support de pipette 505671, cellule modèle, borne à vis pour sorties numériques, matériel de montage en rack ; suite logicielle SutterPatch® avec licence Igor Pro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15.4776%;\"\u003eSU-DPATCH-2\u003c\/td\u003e\n\u003ctd style=\"width: 38.4522%;\"\u003eSystème dPatch avec deux headstages et préamplificateurs\u003c\/td\u003e\n\u003ctd style=\"width: 46.0701%;\"\u003eComprend : système dPatch avec deux headstages et préamplificateurs, deux supports de pipette 505671, deux cellules modèle, bornes à vis pour sorties numériques, matériel de montage en rack ; suite logicielle SutterPatch® avec licence Igor Pro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSUPPORT LÉGENDAIRE\u003c\/h2\u003e\n\u003cp\u003eSutter a une longue histoire de soutien à nos produits et de leur amélioration continue. Alors que d'autres amplificateurs sur le marché n'ont pas été mis à jour depuis 20 ans, le dPatch continuera d'être développé et supporté BIEN dans le futur. Tous nos produits sont fabriqués aux USA, et nous offrons un support gratuit si vous avez besoin d'aide.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eTAUX D'ÉCHANTILLONNAGE DE 5 MHz, JUSQU'À 22 BITS DE RÉSOLUTION\u003c\/h2\u003e\n\u003cp\u003eUne caractéristique unique du dPatch est le système d'échantillonnage des données du headstage. Chaque headstage est échantillonné en continu à 5 MHz. Le filtrage de sortie propose treize réglages entre 100 Hz et 1 MHz. Une résolution de 18 bits est atteinte à 1 MHz. Pour des réglages de filtre plus bas, le sous-échantillonnage automatique augmente la résolution tout en optimisant les débits de données. À un réglage de bande passante de 1 kHz, le système dPatch offre une résolution de signal supérieure à 22 bits.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eREFROIDISSEMENT ACTIF NON REQUIS\u003c\/h2\u003e\n\u003cp\u003eLe refroidissement actif cause de nombreux problèmes qui créent en fait plus de « bruit » à long terme. Le refroidissement actif dans les headstages d'amplificateur utilise des cellules Peltier, qui refroidissent l'électronique pour une performance légèrement meilleure, mais génèrent une chaleur considérable de l'autre côté de la cellule. La chaleur générée provoque une dérive thermique qui rend presque impossible de rester connecté lors de travaux sur un seul canal. C'est LA SOURCE LA PLUS COURANTE de ce que les utilisateurs perçoivent comme une « dérive du manipulateur ». En tant qu'entreprise fabriquant des micromanipulateurs, nous sommes très sensibles à la performance du système dans un ensemble complet d'électrophysiologie.\u003c\/p\u003e\n\u003cp\u003eLe refroidissement actif peut aider à obtenir une spécification de bruit légèrement meilleure sur le papier, mais dans la réalité, les inconvénients l'emportent largement sur le léger gain en spécification. L'un des objectifs de développement du dPatch headstage était d'atteindre une performance de bruit comparable à température ambiante, sans besoin d'un headstage refroidi. Dans les deux modes de rétroaction résistive, l'amplificateur dPatch est même plus silencieux que tous les systèmes concurrents. De plus, la durée de vie limitée des éléments Peltier soulève des préoccupations de fiabilité que nous avons jugées inacceptables.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eSYSTÈME D'ACQUISITION DE DONNÉES INTÉGRÉ SIGNIFIE AUCUNE INTERFACE INFORMATIQUE TIERS\u003c\/h2\u003e\n\u003cp\u003eGrâce à une conception sans multiplexeur, le dPatch offre 8 canaux d'entrée analogique différentielle complète, 4 canaux de sortie analogique et 16 sorties numériques (TTL). Tous les canaux E\/S sont échantillonnés en continu (200 kHz pour les entrées analogiques, 250 kHz pour les sorties analogiques et numériques) et accessibles via l'interface utilisateur.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eLOGICIEL SUTTERPATCH\u003c\/h2\u003e\n\u003cp\u003eLe système d'amplificateur dPatch, en combinaison avec le logiciel SutterPatch, a été conçu pour capturer et stocker automatiquement tous les réglages de l'amplificateur, les informations sur les stimuli et les paramètres externes de l'expérience, et les associer dans le temps aux traces de données brutes. Cela inclut tous les réglages de l'amplificateur et de l'acquisition, ainsi que le timing et le déroulement de l'expérience. Le contrôle informatique entièrement intégré des étages de l'amplificateur signifie que le logiciel d'acquisition est constamment informé de l'état interne de l'amplificateur et du numériseur et peut suivre tout changement pouvant survenir. Cela est indépendant du fait qu'un changement soit déclenché automatiquement ou initié par l'utilisateur.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan style=\"color: red;\"\u003e●NOUVELLE FONCTIONNALITÉ● \u003c\/span\u003eCLAMP DYNAMIQUE\u003c\/h2\u003e\n\u003cp\u003eL'architecture numérique brevetée du système d'amplificateur dPatch offre une plateforme idéale pour le clamp dynamique. Le dPatch est alimenté par un système sur puce qui fournit un traitement parallèle via un Field Programmable Gate Array (FPGA) et deux processeurs ARM haute vitesse. Plusieurs modèles sophistiqués de clamp dynamique sont implémentés dans cette architecture. Dans chaque modèle, la mise à jour des valeurs de courant appliquées se fait sans communication entre le dPatch et un ordinateur. Selon la complexité du modèle, des taux de mise à jour allant jusqu'à 500 kHz peuvent être atteints. \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eSUIVI D'AUTRES DONNÉES EXTERNES\u003c\/h2\u003e\n\u003cp\u003eEn plus des changements d'état du matériel connecté qui sont automatiquement suivis, le chercheur peut déclencher manuellement des balises pour documenter des événements tels que l'application de stimuli à l'aide d'instruments non connectés à l'amplificateur. Des informations sur les paramètres environnementaux et une spécification plus détaillée des propriétés de l'échantillon peuvent être enregistrées et stockées avec les données brutes. Plus de 650 attributs de métadonnées sont pris en charge. Parmi les exemples : espèce animale, génotype, date\/heure de préparation d'un échantillon cellulaire, solutions d'enregistrement, résistance de la pipette, propriétés du matériel et informations détaillées sur les stimuli appliqués.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eVISUALISATION ET ANALYSE DES DONNÉES\u003c\/h2\u003e\n\u003cp\u003eLe logiciel SutterPatch a été conçu pour simplifier la navigation et l'analyse de jeux de données complexes. La fenêtre de portée prend en charge plusieurs modes d'affichage en deux dimensions ainsi qu'un affichage innovant en trois dimensions. La vue 3D est particulièrement utile lors du développement d'essais. Basé sur la dernière version de la plateforme éprouvée Igor Pro, SutterPatch combine les fonctionnalités natives d'Igor Pro avec une multitude de fonctionnalités adaptées aux applications d'électrophysiologie. Tant le débutant que l'utilisateur expérimenté de programmes de patch clamp se sentiront à l'aise avec le logiciel SutterPatch.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eLes modules d'application fournissent des fonctionnalités ciblées pour des applications particulières.\u003cbr\u003e\u003cbr\u003e\u003cem\u003eActuellement disponible :\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eModule de détection d'événements : un algorithme de déconvolution qui excelle à détecter les événements synaptiques miniatures même sur un fond bruité.\u003c\/li\u003e\n\u003cli\u003eModule d'analyse du potentiel d'action : graphique du plan de phase, statistiques de synchronisation et de forme d'onde.\u003c\/li\u003e\n\u003cli\u003eModule caméra : un moyen simple de documenter l'identité et l'état de la cellule enregistrée.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eUN CHEVAL DE BATAILLE DE LABORATOIRE\u003c\/h2\u003e\n\u003cp\u003eBien que le système dPatch soit prêt pour la recherche de pointe, son ensemble de fonctionnalités le rend immédiatement utile dans tout laboratoire.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTrois plages de rétroaction de tête pour un enregistrement optimal whole-cell et monocanal\u003c\/li\u003e\n\u003cli\u003eCompensation automatisée de la capacité de l'électrode et de la cellule entière\u003c\/li\u003e\n\u003cli\u003eCompensation de la résistance série\u003c\/li\u003e\n\u003cli\u003eCâblage simple, installation rapide et facile\u003c\/li\u003e\n\u003cli\u003eLa large plage dynamique du numériseur évite le besoin d'étages à gain variable\u003c\/li\u003e\n\u003cli\u003eLa grande vitesse du numériseur élimine les soucis liés au taux d'échantillonnage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\n\u003cbr\u003eAPPLICATIONS COURANTES :\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli type=\"square\"\u003eEnregistrements monocanaux\u003c\/li\u003e\n\u003cli type=\"square\"\u003eRecherche auditive et autres signaux à évolution rapide\u003c\/li\u003e\n\u003cli type=\"square\"\u003eEnregistrements sur tranches de tissu\u003c\/li\u003e\n\u003cli type=\"square\"\u003eExpériences sur cellules en culture\u003c\/li\u003e\n\u003cli type=\"square\"\u003eÉtudes sur lignées cellulaires à partir de cellules adhérentes ou dispersées\u003c\/li\u003e\n\u003cli type=\"square\"\u003eOptogénétique\u003c\/li\u003e\n\u003cli type=\"square\"\u003eRecherche sur nanopores et nanogaps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eCARACTÉRISTIQUES\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSupport technique gratuit\u003c\/li\u003e\n\u003cli\u003eAmplificateur patch clamp à tête simple ou double et système d'acquisition de données entièrement intégrés garantissant une installation rapide et facile\u003c\/li\u003e\n\u003cli\u003eOptimisé pour les enregistrements patch clamp monocanal et whole-cell dans des tranches de tissu, cellules adhérentes ou dissociées\u003c\/li\u003e\n\u003cli\u003eContrôle informatique complet assurant la compensation automatisée de la capacité de l'électrode et de la cellule entière\u003c\/li\u003e\n\u003cli\u003eClamp de tension, clamp de courant FastFollower™ et capacité de clamp dynamique entièrement intégrée pour une caractérisation complète de l'activité électrique des cellules\u003c\/li\u003e\n\u003cli\u003eRéduction de la fréquence secteur dans SutterPatch\u003c\/li\u003e\n\u003cli\u003eAmplificateur à verrouillage logiciel dans SutterPatch pour des mesures de capacité haute résolution\u003c\/li\u003e\n\u003cli\u003eLarge bande passante permettant la caractérisation des signaux les plus rapides\u003c\/li\u003e\n\u003cli\u003eTrois plages de rétroaction de tête pour enregistrements patch clamp monocanal et whole-cell\u003c\/li\u003e\n\u003cli\u003eCircuiterie de compensation numérique complète offrant une précision et une fidélité du signal optimales\u003c\/li\u003e\n\u003cli\u003eLe logiciel SutterPatch® inclus offre une gestion polyvalente des données, une navigation intuitive et une analyse des données simplifiée.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eAccessoires\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePoint de masse\u003c\/strong\u003e\u003cbr\u003eLe point de masse (#505673) fournit des connexions fiables à faible résistance pour une configuration de masse en étoile, la méthode éprouvée pour éviter les boucles de masse dans toute installation d'électrophysiologie. Accepte 9 fiches banane + 8 fils nus jusqu'au calibre 10 ou fiches banane. La plaque de base se monte directement sur des tables à air impériales ou métriques avec les vis ¼-20 et M6 fournies. Fabriqué en laiton massif usiné avec connecteurs banane\/pince plaqués.\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.sutter.com\/productLG\/gp-17_lg.jpg\" target=\"_blank\"\u003e\u003cimg align=\"center\" width=\"300\" alt=\"gp-17\" src=\"https:\/\/www.sutter.com\/productSM\/gp-17_sm.jpg\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cbr\u003e\u003cstrong\u003ePanneau d'extension dPatch\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.sutter.com\/productLG\/dpa_expansion_3-4_lg.jpg\" target=\"_blank\"\u003e\u003cimg border=\"0\" align=\"center\" width=\"500\" alt=\"Extension dPatch\" src=\"https:\/\/www.sutter.com\/productSM\/dpa_expansion_3-4_sm.jpg\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:resources --\u003e\n\u003ch2\u003eManuel utilisateur\u003c\/h2\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.sutter.com\/manuals\/dPatch_SutterPatch_OpMan.pdf\" title=\"\" target=\"_blank\"\u003eManuel d'utilisation dPatch \u0026amp; SutterPatch\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eINFORMATIONS PRODUIT\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.sutter.com\/PDFs\/Comparison_aX.pdf\"\u003eComparaison avec la marque aX\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.sutter.com\/Flyers\/DynamicClamp_flyer.pdf\"\u003eBrochure Dynamic Clamp\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.sutter.com\/Flyers\/DPA_flyer.pdf\"\u003eBrochure de vente dPatch (version anglaise)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.sutter.com\/Flyers\/SutterPatch_flyer.pdf\"\u003eBrochure de vente SutterPatch®\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.sutter.com\/PDFs\/Comparison_Amplifier_Systems.pdf\"\u003eComparaison des systèmes amplificateurs Sutter\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003ePUBLICATIONS SCIENTIFIQUES\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.sutter.com\/PDFs\/IPA_dPA_SutterPatch_Publications.pdf\"\u003eExpériences d'intérêt impliquant les systèmes amplificateurs Sutter Instrument et le logiciel SutterPatch®\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.sutter.com\/PDFs\/Patch_Clamp_Technology_TwentyFirst_Century.pdf\" target=\"_blank\"\u003eChapitre de livre : Technologie Patch Clamp au XXIe siècle\u003c\/a\u003e\u003cbr\u003eDans : \u003ca rel=\"noopener\" href=\"https:\/\/doi.org\/10.1007\/978-1-0716-0818-0_2\" target=\"_blank\"\u003eDallas M., Bell D. (éds) Patch Clamp Electrophysiology. Méthodes en biologie moléculaire, vol 2188. Humana, New York, NY\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eVIDÉOS\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/youtu.be\/T2fKGV-eQl8\"\u003eWEBINAIRE : Clamp dynamique et analyse inter-expériences\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/yQO33mOaO38\" target=\"_blank\"\u003eVidéo d'information SutterPatch\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/fTAOWTVw8mc\"\u003ePrésentation SutterPatch : #1 Introduction\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/OaZ1mCtyb3I\"\u003ePrésentation SutterPatch : #2 Contrôle de l'amplificateur\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/IIzmJVZlL_E\"\u003ePrésentation SutterPatch : #3 Routines\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/HVMup1iDVCI\"\u003ePrésentation SutterPatch : #4 Navigateur de données et métadonnées\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/hpu_UJmJ3nM\"\u003ePrésentation SutterPatch : #5 Modules d'application\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ : Comment le dPatch® se compare-t-il aux autres amplificateurs sur le marché ?\u003c\/strong\u003e\u003cbr\u003eR : Le dPatch utilise une architecture numérique de pointe. En convertissant le signal de l'analogique au numérique près de la tête d'amplificateur, nous préservons l'intégrité du signal autant que possible. Presque toutes les spécifications de bruit du dPatch dépassent celles de tous les autres amplificateurs sur le marché. De plus, le dPatch constitue un système complet de patch clamp, tout le matériel et logiciel d'acquisition de données sont inclus, et aucun matériel externe n'est requis pour le clamp dynamique. \u003ca href=\"https:\/\/www.sutter.com\/PDFs\/Comparison_aX.pdf\"\u003e(voir notre fiche de comparaison)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ : Pourquoi le dPatch n'a-t-il pas de refroidissement actif ?\u003c\/strong\u003e\u003cbr\u003eR : Le refroidissement actif cause de nombreux problèmes qui génèrent en fait plus de \"bruit\" à long terme. La chaleur produite par les cellules Peltier provoque une dérive thermique dans les manipulateurs, rendant presque impossible de rester en patch lors de travaux sur un seul canal. En tant qu'entreprise fabriquant des micromanipulateurs, nous sommes très sensibles à la performance du système dans un ensemble complet d'électrophysiologie. Le refroidissement actif peut aider à obtenir une spécification de bruit légèrement meilleure sur le papier, mais dans la réalité les inconvénients l'emportent largement sur le léger gain en spécifications (voir la fiche de comparaison). De plus, la durée de vie limitée des éléments Peltier soulève des préoccupations de fiabilité que nous avons jugées inacceptables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ : Dois-je acheter un numériseur ou un logiciel avec le dPatch ?\u003c\/strong\u003e\u003cbr\u003eR : Non, car le dPatch est intrinsèquement une conception numérique, aucun numériseur supplémentaire n'est nécessaire. Le logiciel SutterPatch® et une licence pour IgorPro sont inclus avec chaque système dPatch. Le dPatch comprend tout ce dont vous avez besoin pour commencer vos expériences.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ : Puis-je ajouter une seconde tête d'amplificateur à mon système dPatch à tête unique ultérieurement ?\u003c\/strong\u003e\u003cbr\u003eR : Oui, les unités tête d'amplificateur\/préamplificateur dPatch sont interchangeables et autonomes. Toutes les informations de calibration et de réglage sont stockées directement dans l'unité tête d'amplificateur\/préamplificateur et lues au démarrage. Cela facilite l'ajout d'une seconde tête d'amplificateur.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ : Les têtes d'amplificateur s'adaptent-elles à mon micromanipulateur existant ?\u003c\/strong\u003e\u003cbr\u003eR : Toutes les têtes d'amplificateur Sutter Instrument sont équipées d'un montage standard en queue d'aronde. Ce montage a été introduit conjointement par Sutter Instrument et Axon Instruments il y a près de 30 ans et a depuis été adopté par la plupart des fabricants d'amplificateurs patch clamp et de micromanipulateurs. Cela fait des têtes Sutter un remplacement direct sur un équipement existant, dans la plupart des cas sans nécessiter aucun ajustement.\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:specifications --\u003e\n\u003cp\u003eL'amplificateur patch clamp numérique intégré dPatch est un système à tête unique ou double contrôlé par ordinateur, optimisé pour les applications d'enregistrement sur canal unique et sur cellule entière.\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.sutter.com\/productLG\/dpa_back_lg.jpg\" target=\"_blank\"\u003e\u003cimg align=\"center\" width=\"645\" alt=\"arrière du dPatch\" src=\"https:\/\/www.sutter.com\/productSM\/dpa_back_sm.jpg\"\u003e\u003c\/a\u003e\u003cbr\u003e\u003cem\u003epanneau arrière du dPatch. (Cliquez pour agrandir)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cem\u003eAmplificateur\u003c\/em\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eL'architecture matérielle permet que toute conversion de données soit effectuée près de la préparation, loin des sources de bruit connues, telles que les alimentations et les circuits numériques à haute vitesse.\u003c\/li\u003e\n\u003cli\u003eModes clamp de tension et clamp courant véritable avec commutation intelligente entre les modes pour éviter les artefacts de courant\u003c\/li\u003e\n\u003cli\u003eTrois choix d'éléments de rétroaction de tête pour optimiser à la fois l'enregistrement sur canal unique et sur cellule entière\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\" class=\"product-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003ccenter\u003eRétroaction\u003cbr\u003eÉlément\u003c\/center\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ccenter\u003ePlage\u003c\/center\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ccenter\u003eAnalogique\u003cbr\u003eBande passante\u003c\/center\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ccenter\u003eBruit\u003cbr\u003eBW 10 kHz\u003c\/center\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ccenter\u003ePipette\u003cbr\u003eCompensation\u003cbr\u003ePlage\u003c\/center\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ccenter\u003eSérie\u003cbr\u003eRésistance\u003cbr\u003ePlage\u003c\/center\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ccenter\u003eCellule\u003cbr\u003eCapacité\u003cbr\u003ePlage\u003c\/center\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ccenter\u003eCapacitif\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e±20 nA\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e1 MHz\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u0026lt; 0,22 pA\u003csub\u003erms\u003c\/sub\u003e\n\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e20 pF\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003eN\/A*\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003eN\/A*\u003c\/center\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ccenter\u003e500 MΩ\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e±20 nA\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u0026gt; 250 kHz\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u0026lt; 0,7 pA\u003csub\u003erms\u003c\/sub\u003e\n\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e20 pF\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e100 MΩ\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e100 pF\u003c\/center\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ccenter\u003e50 MΩ\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e±200 nA\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u0026gt; 250 kHz\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u0026lt; 2,3 pA\u003csub\u003erms\u003c\/sub\u003e\n\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e20 pF\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e10 MΩ\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e1000 pF\u003c\/center\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003e\u003csup\u003e*\u003c\/sup\u003e La plage de rétroaction capacitive est optimisée pour les enregistrements en clamp de tension sur canal unique. La compensation cellule entière et le mode clamp courant sont désactivés avec cette plage.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRoutines automatiques de compensation pour la pipette, la cellule entière et la résistance série\u003c\/li\u003e\n\u003cli\u003ePrédiction et correction de la résistance série programmables indépendamment\u003c\/li\u003e\n\u003cli\u003eFiltre Bessel 8 pôles 0,1, 0,2, 0,5, 1, 2, 5, 10, 20, 50, 100, 250, 500, 1000 kHz\u003c\/li\u003e\n\u003cli\u003eTraitement du signal de sortie du filtre pour augmenter la résolution et réduire la taille des fichiers de données\u003c\/li\u003e\n\u003cli\u003eRésolution supérieure à 22 bits avec un filtre réglé à 1 kHz\u003c\/li\u003e\n\u003cli\u003eGrande plage dynamique des convertisseurs analogique-numérique évitant le besoin d'étages de gain de sortie variables\u003c\/li\u003e\n\u003cli\u003ePotentiel de maintien ±1000 mV\u003c\/li\u003e\n\u003cli\u003eCompensation du pont en clamp courant et compensation de la capacité de la pipette\u003c\/li\u003e\n\u003cli\u003eSuivi lent du potentiel de maintien compense la dérive lors des enregistrements en clamp courant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cem\u003eAcquisition de données\u003c\/em\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSystème d'acquisition de données intégré élimine le besoin d'une carte d'acquisition externe\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eTaux d'échantillonnage de 5 MHz par tête, résolution 22 bits\u003c\/li\u003e\n\u003cli\u003e8 entrées analogiques auxiliaires, 16 bits entièrement différentielles, ±10 V, échantillonnées en continu à 200 kHz chacune\u003c\/li\u003e\n\u003cli\u003e4 sorties analogiques, 16 bits, ±10 V chacune mises à jour en continu à 250 kHz\u003c\/li\u003e\n\u003cli\u003e16 sorties numériques (TTL) fonctionnant chacune à 250 kHz\u003c\/li\u003e\n\u003cli\u003eEntrée Trigger IN \/ Sortie Trigger OUT indépendantes pour la synchronisation des instruments externes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eConnexion unique SuperSpeed USB 3.0 contrôle l'acquisition de données et l'amplificateur\u003c\/li\u003e\n\u003cli\u003eFormes d'onde de commande complexes\u003c\/li\u003e\n\u003cli\u003eL'acquisition de données peut être déclenchée par une horloge embarquée à la microseconde ou un déclencheur externe (TTL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cem\u003eLogiciel SutterPatch\u003c\/em\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBasé sur la fondation d'Igor Pro 8 (WaveMetrics, Inc.)\u003c\/li\u003e\n\u003cli\u003eParadigmes et routines offrent un contrôle expérimental complet\u003c\/li\u003e\n\u003cli\u003eÉditeur de forme d'onde pour une création facile des motifs de stimulus les plus complexes ou des modèles définis par l'utilisateur\u003c\/li\u003e\n\u003cli\u003eAssociated Metadata stocke toutes les informations pertinentes concernant votre expérience\u003c\/li\u003e\n\u003cli\u003eRoutines complètes d'analyse de données et graphiques de qualité publication\u003c\/li\u003e\n\u003cli\u003eRéduction rapide en ligne de la fréquence secteur\u003c\/li\u003e\n\u003cli\u003eFonctionne sous Windows 10 ou version ultérieure (64 bits), ou Macintosh OS X 10.11 (El Capitan) ou versions plus récentes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp align=\"center\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.sutter.com\/productLG\/sutterpatch.jpg\" target=\"_blank\"\u003e\u003cimg align=\"center\" width=\"645\" alt=\"Sutterpatch\" src=\"https:\/\/www.sutter.com\/productLG\/sutterpatch.jpg\"\u003e\u003c\/a\u003e\u003cbr\u003e\u003cem\u003eCapture d'écran du logiciel SutterPatch\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPÉCIFICATIONS TECHNIQUES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003cbr\u003e\u003cem\u003edPatch :\u003c\/em\u003e 19 in x 11 in x 3,5 in | 48,2 cm x 28 cm x 9 cm\u003cbr\u003e\u003cbr\u003e\u003cem\u003edPatch Preamplifier :\u003c\/em\u003e 7,6 in x 3,5 in x 1,2 in | 19,5 cm x 9 cm x 3 cm\u003cbr\u003e\u003cbr\u003e\u003cem\u003edPatch Headstage :\u003c\/em\u003e 3,7 in x 1,1 in x 0,66 in | 9,5 cm x 2,9 cm x 1,7 cm\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003ePoids\u003c\/strong\u003e\u003cbr\u003e\u003cem\u003edPatch :\u003c\/em\u003e 15 lbs | 6,8 kg\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eÉlectrique\u003c\/strong\u003e\u003cbr\u003e110\/240 Volts\u003cbr\u003eAlimentation 50\/60 Hertz\u003cbr\u003e\u003cbr\u003e*Brevet n° US 10,393,727 B2\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConforme RoHS\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.sutter.com\/PDFs\/CE\/CE_EU_DoC_DPATCH.pdf\" target=\"_blank\"\u003eCertificat DPATCH CE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg height=\"53\" width=\"75\" alt=\"Logo CE\" src=\"https:\/\/www.sutter.com\/images\/structure\/ce-marking-logo.png\"\u003e   \u003cimg height=\"50\" width=\"50\" alt=\"UKCA\" src=\"https:\/\/www.sutter.com\/images\/structure\/UKCA_74.png\"\u003e   \u003cimg height=\"57\" width=\"65\" alt=\"Chiana CE\" src=\"https:\/\/www.sutter.com\/images\/structure\/China_CE_97.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEXIGENCES SYSTÈME\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eConfiguration minimale :\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWindows 10 (64 bits), ou MacOS : 10.11, El Capitan ou version ultérieure\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProcesseur : i5 double cœur\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eMémoire : 8 Go\u003c\/li\u003e\n\u003cli\u003eDisque SSD (Solid-state drive) : 500 Go ou plus\u003c\/li\u003e\n\u003cli\u003eRésolution d'affichage : 1024 x 768 (XGA)\u003c\/li\u003e\n\u003cli\u003e1 port USB 3.0 SuperSpeed disponible (sur la carte mère, pas une carte PCIx ou similaire)\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003cem\u003eConfiguration recommandée pour des largeurs de bande \u0026gt;50 kHz :\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWindows 10 (64 bits), ou MacOS : 10.11, El Capitan ou version ultérieure\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProcesseur : i5 double cœur\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eMémoire : 16 Go\u003c\/li\u003e\n\u003cli\u003eDisque SSD (Solid-state drive) : 500 Go ou plus\u003c\/li\u003e\n\u003cli\u003eRésolution d'affichage 1920 x 1080 (Full HD)\u003c\/li\u003e\n\u003cli\u003e1 port USB 3.0 SuperSpeed disponible (sur la carte mère, pas une carte PCIx ou similaire)\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSystème de gestion et logiciel d'analyse d'acquisition de données SUTTERPATCH® : inclus avec tous les systèmes d'amplificateurs Sutter Instrument\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003csup\u003e1\u003c\/sup\u003e Les systèmes d'exploitation installés dans des plateformes de virtualisation telles que VMware et Parallels ne sont pas pris en charge.\u003cbr\u003e\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e À ce jour, WaveMetrics ne prend pas entièrement en charge Igor Pro sur les ordinateurs Mac basés sur l'architecture Apple Silicon M1. Voir \u003ca rel=\"noopener\" href=\"https:\/\/www.wavemetrics.com\/news\/igor-and-apple-arm-processors\" target=\"_blank\"\u003ehttps:\/\/www.wavemetrics.com\/news\/igor-and-apple-arm-processors\u003c\/a\u003e pour les détails techniques. Des expériences préliminaires indiquent que le logiciel SutterPatch fonctionne sur ces ordinateurs, à la fois sous Igor Pro 8 et 9, et avec chacun des systèmes d'amplificateurs Sutter connectés. Cependant, comme pour chaque nouvelle technologie, nous ne pouvons pas exclure totalement des incompatibilités.\u003cbr\u003e\u003cbr\u003e\u003csup\u003e3\u003c\/sup\u003e Les ports USB 3.0 sont compatibles avec les spécifications USB 2.0 High Speed.\u003cbr\u003eLes ports USB 2.0 « full-speed » plus lents, que l'on trouve parfois sur les anciens PC Windows ou les cartes d'extension USB, ne sont pas pris en charge.\u003cbr\u003e\u003cbr\u003ePour vérifier la présence d'USB 2.0 High Speed ou USB 3.0 sur un ordinateur PC sous Windows, consultez le Panneau de configuration \u0026gt; Gestionnaire de périphériques \u0026gt; section Contrôleurs de bus USB pour les contrôleurs hôtes « Améliorés ». Comme cela ne fournit aucune information de correspondance avec les ports physiques de l'ordinateur, et qu'il peut y avoir un mélange de versions de ports USB, vous devez vérifier les performances opérationnelles des ports USB individuels pour USB 2.0\/3.0 High Speed. Comme indicateur visuel, les ports USB 3.0 sont souvent codés en bleu.\u003cbr\u003e\u003cbr\u003eLes concentrateurs USB ne sont pas pris en charge. Les cartes d'extension USB, même si elles répondent formellement aux spécifications High Speed ou Super Speed, ne sont pas recommandées. Elles sont souvent configurées architecturale comme des concentrateurs USB et peuvent entraîner des erreurs de transfert intermittentes difficiles à diagnostiquer.\u003cbr\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"53\" width=\"75\" alt=\"Logo CE\" src=\"https:\/\/www.sutter.com\/images\/structure\/ce-marking-logo.png\"\u003e\u003cbr\u003e\u003cimg height=\"59\" width=\"72\" alt=\"RoHS\" src=\"https:\/\/www.sutter.com\/images\/structure\/rohs.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Système dPatch avec une tête et préamplificateur","offer_id":42267582464090,"sku":"SU-DPATCH","price":29630.01,"currency_code":"USD","in_stock":true},{"title":"Système dPatch avec deux têtes et préamplificateur","offer_id":42267582496858,"sku":"SU-DPATCH-2","price":35829.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/double_dpa_lg_c7fa529a-e687-4700-bbc0-31dea413bb84.jpg?v=1766414927"},{"product_id":"var-su-ipa-ipa-system","title":"Système IPA","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable class=\"product-table\" style=\"height: 54px; width: 100%;\" width=\"100%\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"height: 18px;\"\u003e\r\n\u003ctd style=\"text-align: center; height: 18px; width: 15.2358%;\"\u003e\u003cstrong\u003eCode de commande\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; height: 18px; width: 36.5175%;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 48.2467%;\"\u003e\u003cstrong\u003eDétails\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 18px;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 15.2358%;\"\u003eSU-IPA\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 36.5175%;\"\u003eSystème IPA avec tête d'amplificateur\u003c\/td\u003e\r\n\u003ctd style=\"width: 48.2467%;\"\u003eComprend : système IPA avec tête d'amplificateur, porte-pipette 505671, cellule modèle, câble de dérivation « octopus », matériel de montage en rack ; suite logicielle SutterPatch® avec licence Igor Pro\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 18px;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 15.2358%;\"\u003eSU-IPA2\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 36.5175%;\"\u003eSystème IPA double avec deux têtes d'amplificateur\u003c\/td\u003e\r\n\u003ctd style=\"width: 48.2467%;\"\u003eComprend : système IPA double avec deux têtes d'amplificateur, deux porte-pipettes 505671, cellule modèle, câble de dérivation « octopus », matériel de montage en rack ; suite logicielle SutterPatch® avec licence Igor Pro.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003ch2\u003eEntrées et sorties externes\u003c\/h2\u003e\r\n\u003cp\u003eDes signaux externes, tels que des paramètres environnementaux ou des informations sur les stimuli, peuvent être enregistrés à l'aide de 4 canaux d'entrée analogiques auxiliaires. Les systèmes IPA prennent également en charge le contrôle du matériel périphérique, comme les commutateurs de longueur d'onde ou de solution, avec 2 canaux de sortie analogiques et 8 canaux de sortie numériques (TTL). En alternative au câble de dérivation standard, un panneau de connexion optionnel offre une manière ordonnée de connecter les signaux auxiliaires à l'avant de votre rack.\u003c\/p\u003e\r\n\u003ch2\u003eLogiciel SutterPatch\u003c\/h2\u003e\r\n\u003cp\u003eLe système IPA, en combinaison avec le logiciel SutterPatch, a été conçu pour capturer et stocker automatiquement tous les réglages de l'amplificateur, les informations sur les stimuli et les paramètres externes de l'expérience, et les associer dans le temps aux traces de données brutes. Cela inclut tous les réglages de l'amplificateur et de l'acquisition, ainsi que le timing et le déroulement de l'expérience. Le contrôle informatique entièrement intégré des étages d'amplification signifie que le logiciel d'acquisition connaît en permanence l'état interne de l'amplificateur et du numériseur et peut suivre tout changement qui pourrait survenir. Cela est indépendant du fait qu'un changement soit déclenché automatiquement ou initié par l'utilisateur.\u003c\/p\u003e\r\n\u003ch2\u003eSuivi d'autres données externes\u003c\/h2\u003e\r\n\u003cp\u003eEn plus des changements d'état du matériel connecté qui sont automatiquement suivis, l'expérimentateur peut déclencher manuellement des balises pour documenter des événements comme l'application d'un stimulus sur des instruments non connectés au système IPA.\u003cbr\u003e\u003cbr\u003eDes informations sur les paramètres environnementaux et une spécification plus détaillée des propriétés de l'échantillon peuvent être enregistrées et stockées avec les données brutes. Plus de 600 attributs de métadonnées sont pris en charge. Parmi les exemples : espèce animale, souche, génotype, date\/heure de préparation d'un échantillon cellulaire, solutions d'enregistrement, résistance de la pipette, propriétés matérielles et informations détaillées sur les stimuli appliqués.\u003c\/p\u003e\r\n\u003ch2\u003eVisualisation et analyse des données\u003c\/h2\u003e\r\n\u003cp\u003eLe logiciel SutterPatch a été conçu pour simplifier la navigation et l'analyse de jeux de données complexes. La fenêtre de visualisation prend en charge plusieurs modes d'affichage en deux dimensions ainsi qu'un affichage innovant en trois dimensions. La vue 3D est particulièrement utile lors du développement de tests. Basé sur la dernière version de la plateforme éprouvée Igor Pro, le programme SutterPatch combine les fonctionnalités natives d'Igor Pro avec une multitude de fonctionnalités adaptées aux applications d'électrophysiologie. Tant le novice que l'utilisateur expérimenté de programmes de patch clamp se sentiront à l'aise avec le logiciel SutterPatch.\u003c\/p\u003e\r\n\u003cp\u003eLes modules d'application offrent des fonctionnalités ciblées pour des applications particulières.\u003c\/p\u003e\r\n\u003cul\u003eActuellement disponible :\r\n\u003cli\u003e\n\u003cem\u003eModule de détection d'événements :\u003c\/em\u003e Un algorithme de déconvolution qui excelle à détecter les événements synaptiques miniatures même sur un fond bruité\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cem\u003eModule d'analyse du potentiel d'action :\u003c\/em\u003e Graphique phase-plane, statistiques de synchronisation et de forme d'onde\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cem\u003eModule caméra :\u003c\/em\u003e Un moyen simple de documenter l'identité et l'état de la cellule enregistrée\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eLes amplificateurs patch clamp intégrés IPA et Double IPA sont des amplificateurs à tête unique ou double contrôlés par ordinateur, optimisés pour les applications d'enregistrement whole-cell.\u003c\/p\u003e\r\n\u003ch2 style=\"text-align: left;\" align=\"center\"\u003eAPPLICATIONS COURANTES\u003c\/h2\u003e\r\n\u003cdiv\u003e\r\n\u003cul\u003e\r\n\u003cli type=\"square\"\u003eEnregistrements sur tranches de tissu\u003c\/li\u003e\r\n\u003cli type=\"square\"\u003eExpériences sur cellules en culture\u003c\/li\u003e\r\n\u003cli type=\"square\"\u003eÉtudes de lignées cellulaires à partir de cellules adhérentes ou dispersées\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003c\/div\u003e\r\n\u003cdiv\u003e\r\n\u003cul\u003e\r\n\u003cli type=\"square\"\u003e\nPatch clamp \u003cem\u003ein vivo\u003c\/em\u003e\u003c\/li\u003e\r\n\u003cli type=\"square\"\u003eÉtudes en réseau\u003c\/li\u003e\r\n\u003cli type=\"square\"\u003eOptogénétique\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003c\/div\u003e\r\n\u003cdiv\u003e \u003c\/div\u003e\r\n\u003ch2\u003eCARACTÉRISTIQUES\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\n\u003cstrong\u003eNOUVEAU :\u003c\/strong\u003e Combinaison de deux appareils IPA ou Double IPA permettant jusqu'à quatre canaux de tête pour jusqu'à 16 signaux\u003c\/li\u003e\r\n\u003cli\u003eAmplificateur patch clamp et système d'acquisition de données entièrement intégrés garantissant une installation rapide et facile\u003c\/li\u003e\r\n\u003cli\u003eOptimisé pour les enregistrements en patch clamp whole-cell dans des tranches de tissu, cellules adhérentes ou dissociées\u003c\/li\u003e\r\n\u003cli\u003eContrôle informatique complet offrant une compensation automatisée de la capacité des électrodes et de la cellule entière\u003c\/li\u003e\r\n\u003cli\u003eCapacité de voltage et clamp de courant pour une caractérisation complète de l'activité électrique des cellules\u003c\/li\u003e\r\n\u003cli\u003eLe logiciel SutterPatch inclus excelle dans la gestion complète des données, la navigation intuitive et l'analyse simplifiée des données\u003c\/li\u003e\r\n\u003cli\u003eRéduction de la fréquence secteur dans SutterPatch\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2 style=\"text-align: left;\" align=\"center\"\u003eACCESSOIRES\u003c\/h2\u003e\r\n\u003cp\u003e\u003cstrong\u003ePanneau de patch IPA optionnel\u003c\/strong\u003e\u003cbr\u003eLes amplificateurs IPA et Double IPA sont livrés de série avec un câble de dérivation \"pieuvre\" pour les entrées et sorties auxiliaires, ainsi que les sorties numériques. Le panneau de patch IPA optionnel, usiné dans un bloc d'aluminium de ½\" d'épaisseur comme la face avant de l'IPA, amène les connexions E\/S auxiliaires à l'avant du rack dans un panneau de montage en rack 2U soigné avec connecteurs BNC. Le panneau de patch IPA inclut un câble de connexion de 2,5 ft (76 cm) et remplace le câble standard livré avec le système IPA.\u003cbr\u003e\u003ca href=\"https:\/\/www.sutter.com\/productLG\/ipa_patch_lg.jpg\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/www.sutter.com\/productSM\/ipa_patch_sm.jpg\" alt=\"Patch IPA\" width=\"645\" align=\"center\"\u003e\u003c\/a\u003e\u003cbr\u003e\u003cstrong\u003ePoint de masse\u003c\/strong\u003e\u003cbr\u003eLe Ground Point (505673) offre des connexions fiables à faible résistance pour les connexions de masse en étoile, la méthode éprouvée pour éviter les boucles de masse dans toute installation d'électrophysiologie. Accepte 9 fiches banane + 8 fils nus jusqu'au calibre 10 ou fiches banane. La plaque de base se monte directement sur des plateaux de table à air standard ou métriques avec les vis ¼-20 et M6 fournies. Fabriqué en laiton massif usiné avec connecteurs banane\/pince plaqués.\u003c\/p\u003e\r\n\u003cp align=\"center\"\u003e\u003ca href=\"https:\/\/www.sutter.com\/productLG\/gp-17_lg.jpg\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/www.sutter.com\/productSM\/gp-17_sm.jpg\" alt=\"GP 17\" width=\"300\" align=\"center\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003ch2\u003eMANUELS UTILISATEUR\u003c\/h2\u003e\r\n\u003cp\u003e\u003ca href=\"https:\/\/www.sutter.com\/manuals\/IPA_SutterPatch_QSGuide.pdf\" target=\"new\"\u003eGuide de démarrage rapide IPA \u0026amp; SutterPatch\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.sutter.com\/manuals\/IPA_SutterPatch_OpMan.pdf\" target=\"new\"\u003eManuel d'utilisation IPA \u0026amp; SutterPatch\u003c\/a\u003e\u003c\/p\u003e\r\n\u003ch2\u003eINFORMATIONS PRODUIT\u003c\/h2\u003e\r\n\u003cp\u003e\u003cstrong\u003eDépliant de vente IPA \/ DOUBLE IPA :\u003c\/strong\u003e \u003ca href=\"https:\/\/www.sutter.com\/Flyers\/IPA_flyer.pdf\" target=\"new\"\u003eAnglais\u003c\/a\u003e \/ \u003ca href=\"https:\/\/www.sutter.com\/Flyers\/IPA_flyer_china.pdf\" target=\"new\"\u003eChinois\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.sutter.com\/Flyers\/SutterPatch_flyer.pdf\" target=\"new\"\u003eBrochure commerciale SutterPatch\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.sutter.com\/PDFs\/Comparison_Amplifier_Systems.pdf\" target=\"new\"\u003eComparaison des systèmes d'amplificateurs Sutter\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/yQO33mOaO38\" target=\"_blank\" rel=\"noopener\"\u003eVidéo d'information SutterPatch\u003c\/a\u003e\u003c\/p\u003e\r\n\u003ch2\u003ePUBLICATIONS SCIENTIFIQUES\u003c\/h2\u003e\r\n\u003cp\u003e\u003ca href=\"https:\/\/www.sutter.com\/PDFs\/IPA_dPA_SutterPatch_Publications.pdf\" target=\"new\"\u003eExpériences d'intérêt impliquant les systèmes d'amplificateurs Sutter Instrument et le logiciel SutterPatch®\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.sutter.com\/PDFs\/Patch_Clamp_Technology_TwentyFirst_Century.pdf\" target=\"_blank\" rel=\"noopener\"\u003eChapitre de livre : Technologie Patch Clamp au XXIe siècle\u003c\/a\u003e\u003cbr\u003eDans : \u003ca href=\"https:\/\/doi.org\/10.1007\/978-1-0716-0818-0_2\" target=\"_blank\" rel=\"noopener\"\u003eDallas M., Bell D. (éditeurs) Patch Clamp Electrophysiology. Methods in Molecular Biology, vol 2188. Humana, New York, NY\u003c\/a\u003e\u003c\/p\u003e\r\n\u003ch2\u003eVIDÉOS\u003c\/h2\u003e\r\n\u003cp\u003e\u003ca href=\"https:\/\/youtu.be\/yQO33mOaO38\" target=\"_blank\" rel=\"noopener\"\u003eVidéo d'information SutterPatch\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/fTAOWTVw8mc\" target=\"new\"\u003ePrésentation SutterPatch : #1 Introduction\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/OaZ1mCtyb3I\" target=\"new\"\u003ePrésentation SutterPatch : #2 Contrôle de l'amplificateur\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/IIzmJVZlL_E\" target=\"new\"\u003ePrésentation SutterPatch : #3 Routines\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/HVMup1iDVCI\" target=\"new\"\u003ePrésentation SutterPatch : #4 Navigateur de données et métadonnées\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/hpu_UJmJ3nM\" target=\"new\"\u003ePrésentation SutterPatch : #5 Modules d'application\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/T2fKGV-eQl8\" target=\"new\"\u003eWEBINAIRE : Clamp dynamique et analyse inter-expériences\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/v.youku.com\/v_show\/id_XNDY0Mzk5OTUyNA\" target=\"new\"\u003eWEBINAIRE : Clamp dynamique et analyse inter-expériences (Youku)\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ch2\u003eAmplificateur\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eModes clamp tension et clamp courant véritable avec commutation intelligente entre les modes pour éviter les artefacts de courant\u003c\/li\u003e\r\n\u003cli\u003eBruit en circuit ouvert (RMS) de 1,4 pA dans une bande passante de 0,1-10 kHz\u003c\/li\u003e\r\n\u003cli\u003eRésistance de rétroaction de tête de 500 MΩ offrant une plage maximale de ±20 nA\u003c\/li\u003e\r\n\u003cli\u003eCompensation rapide de la capacité de la pipette et compensation whole-cell\u003c\/li\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eCompensation de la capacité de la pipette jusqu'à 25 pF\u003c\/li\u003e\r\n\u003cli\u003eCompensation whole-cell : C\u003csub\u003em\u003c\/sub\u003e de 1 à 100 pF ; R\u003csub\u003es\u003c\/sub\u003e de 1 à 100 MΩ\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cli\u003eRoutines de compensation automatiques embarquées\u003c\/li\u003e\r\n\u003cli\u003ePrédiction et correction de la résistance série (0-100 MΩ)\u003c\/li\u003e\r\n\u003cli\u003eFiltre passe-bas Bessel à quatre pôles (fréquence de coupure = 0,5 – 20 kHz)\u003c\/li\u003e\r\n\u003cli\u003eGain de sortie : 0,5-25 mV\/pA (clamp tension) ; 10-500 mV\/mV (clamp courant)\u003c\/li\u003e\r\n\u003cli\u003ePotentiel de maintien ±1000 mV\u003c\/li\u003e\r\n\u003cli\u003eCompensation du pont en clamp courant et neutralisation de la capacité\u003c\/li\u003e\r\n\u003cli\u003eSuivi lent du potentiel de maintien compensant la dérive lors des enregistrements en clamp courant\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eAcquisition de données\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eSystème d'acquisition de données intégré éliminant le besoin d'une carte d'acquisition externe et facilitant la configuration\u003c\/li\u003e\r\n\u003cli\u003eConnexion USB haute vitesse unique contrôlant l'acquisition de données et l'amplificateur\u003c\/li\u003e\r\n\u003cli\u003eJusqu'à 6 ou 8 canaux d'entrée (taux d'échantillonnage de 0,1 à 50 kHz par canal)\u003c\/li\u003e\r\n\u003cli\u003eTaux d'échantillonnage agrégé jusqu'à 400 kHz\u003c\/li\u003e\r\n\u003cli\u003eMode multi-amplificateur : une combinaison de deux amplificateurs IPA ou Double IPA peut être connectée, offrant jusqu'à 16 canaux d'entrée\u003c\/li\u003e\r\n\u003cli\u003eFormes d'onde de commande complexes\u003c\/li\u003e\r\n\u003cli\u003eEntrée \/ sortie auxiliaire pour le contrôle d'autres instruments\u003c\/li\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e4 canaux d'entrée analogiques (±10 V)\u003c\/li\u003e\r\n\u003cli\u003e2 canaux de sortie analogiques (±10 V)\u003c\/li\u003e\r\n\u003cli\u003e8 canaux de sortie numériques (TTL)\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cli\u003eL'acquisition de données peut être déclenchée par une horloge interne à la microseconde ou un déclencheur externe (TTL)\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eLogiciel SutterPatch®\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eBasé sur la plateforme Igor Pro (WaveMetrics, Inc.)\u003c\/li\u003e\r\n\u003cli\u003eParadigmes et routines offrent un contrôle expérimental complet\u003c\/li\u003e\r\n\u003cli\u003eÉditeur de formes d'onde pour une création facile des motifs de stimulation les plus complexes ou des modèles définis par l'utilisateur\u003c\/li\u003e\r\n\u003cli\u003eLes métadonnées associées stockent toutes les informations pertinentes concernant votre expérience\u003c\/li\u003e\r\n\u003cli\u003eRoutines complètes d'analyse de données et graphiques de qualité publication\u003c\/li\u003e\r\n\u003cli\u003eFonctionne sous Windows 10 ou version ultérieure (64 bits) ou Mac OS X 10.11 (El Capitan) ou version ultérieure\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003ca href=\"https:\/\/www.sutter.com\/productLG\/sutterpatch.jpg\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/www.sutter.com\/productLG\/sutterpatch.jpg\" alt=\"Patch Sutter\" width=\"645\" align=\"center\"\u003e\u003c\/a\u003e \u003c\/p\u003e\r\n\u003cp\u003e\u003cem\u003eCapture d'écran du logiciel SutterPatch\u003c\/em\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\r\n\u003ch2\u003eSPÉCIFICATIONS TECHNIQUES\u003c\/h2\u003e\r\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003cbr\u003e\u003cem\u003eIPA® :\u003c\/em\u003e 18,8 in x 11,8 in x 1,8 in | 48 cm x 30 cm x 4,5 cm\u003cbr\u003e\u003cem\u003eDOUBLE IPA® :\u003c\/em\u003e 18,8 in x 11,8 in x 3,5 in | 48 cm x 30 cm x 9 cm\u003cbr\u003e\u003cem\u003eIPA Headstage :\u003c\/em\u003e 4,0 in x 1,4 in x 0,75 in | 10 cm x 3,5 cm x 1,9 cm\u003cbr\u003e\u003cem\u003ePanneau de brassage :\u003c\/em\u003e 18,8 in x 2,0 in x 3,5 in | 48 cm x 5 cm x 9 cm\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003ePoids\u003c\/strong\u003e\u003cbr\u003e\u003cem\u003eIPA :\u003c\/em\u003e 9 lbs | 4 kg\u003cbr\u003e\u003cem\u003eDOUBLE IPA :\u003c\/em\u003e 8,1 lbs | 3,7 kg\u003cbr\u003e\u003cem\u003ePanneau de brassage :\u003c\/em\u003e 3,5 lbs | 1,6 kg\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eÉlectrique\u003c\/strong\u003e\u003cbr\u003e110\/240 Volts\u003cbr\u003eAlimentation secteur 50\/60 Hertz\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eConforme RoHS\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.sutter.com\/PDFs\/CE\/CE_EU_DoC_IPA_DOUBLE_IPA.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCertificat CE IPA \u0026amp; DOUBLE IPA\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/www.sutter.com\/images\/structure\/ce-marking-logo.png\" alt=\"CE\" width=\"75\" height=\"53\"\u003e   \u003cimg src=\"https:\/\/www.sutter.com\/images\/structure\/UKCA_74.png\" alt=\"Royaume-Uni CE\" width=\"50\" height=\"50\"\u003e   \u003cimg src=\"https:\/\/www.sutter.com\/images\/structure\/China_CE_97.png\" alt=\"Chine CE\" width=\"65\" height=\"57\"\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eEXIGENCES SYSTÈME\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cem\u003eConfiguration minimale :\u003c\/em\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eWindows 10 (64 bits), ou MacOS : 10.11, El Capitan ou version ultérieure\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/li\u003e\r\n\u003cli\u003eProcesseur : i5 double cœur\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\r\n\u003cli\u003eMémoire : 3 Go\u003c\/li\u003e\r\n\u003cli\u003eDisque dur : 500 Go ou plus\u003c\/li\u003e\r\n\u003cli\u003eRésolution d'affichage : 1024 x 768 (XGA)\u003c\/li\u003e\r\n\u003cli\u003e1 port USB 2.0 High Speed disponible\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cbr\u003e\u003cem\u003eConfiguration recommandée pour des bandes passantes \u0026gt;50 kHz :\u003c\/em\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eWindows 10 (64 bits), ou MacOS : 10.11, El Capitan ou version ultérieure\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/li\u003e\r\n\u003cli\u003eProcesseur : i5 double cœur\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\r\n\u003cli\u003eMémoire : 8 Go\u003c\/li\u003e\r\n\u003cli\u003eDisque SSD (Solid-state drive) : 500 Go ou plus\u003c\/li\u003e\r\n\u003cli\u003eRésolution d'affichage 1920 x 1080 (Full HD)\u003c\/li\u003e\r\n\u003cli\u003e1 port USB 2.0 High Speed disponible\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003eSUTTERPATCH® Système de gestion et logiciel d'acquisition de données : Inclus avec tous les systèmes d'amplificateurs Sutter Instrument\u003c\/p\u003e\r\n\u003cp\u003e\u003cem\u003e\u003csup\u003e1\u003c\/sup\u003e Les systèmes d'exploitation installés dans des plateformes de virtualisation telles que VMware et Parallels ne sont pas pris en charge.\u003cbr\u003e\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e À ce jour, WaveMetrics ne prend pas entièrement en charge Igor Pro sur les ordinateurs Mac basés sur l'architecture Apple Silicon M1. Voir \u003ca href=\"https:\/\/www.wavemetrics.com\/news\/igor-and-apple-arm-processors\" target=\"_blank\" rel=\"noopener\"\u003ehttps:\/\/www.wavemetrics.com\/news\/igor-and-apple-arm-processors\u003c\/a\u003e pour les détails techniques. Des expériences préliminaires indiquent que le logiciel SutterPatch fonctionne sur ces ordinateurs, à la fois sous Igor Pro 8 et 9, et avec chacun des systèmes d'amplificateurs Sutter connectés. Cependant, comme pour toute nouvelle technologie, nous ne pouvons pas exclure complètement des incompatibilités.\u003cbr\u003e\u003cbr\u003e\u003csup\u003e3\u003c\/sup\u003e Les ports USB 3.0 sont compatibles avec les spécifications USB 2.0 High Speed.\u003cbr\u003eLes ports USB 2.0 « full-speed » plus lents, que l'on trouve parfois sur les anciens PC Windows ou les cartes d'extension USB, ne sont pas pris en charge.\u003cbr\u003e\u003cbr\u003ePour vérifier la présence d'USB 2.0 High Speed ou USB 3.0 sur un ordinateur PC sous Windows, consultez le Panneau de configuration \u0026gt; Gestionnaire de périphériques \u0026gt; section Contrôleurs de bus USB pour les contrôleurs hôtes « Améliorés ». Comme cela ne fournit aucune information de correspondance avec les ports physiques de l'ordinateur, et qu'il peut y avoir un mélange de versions de ports USB, vous devez vérifier les performances opérationnelles des ports USB individuels pour USB 2.0\/3.0 High Speed. Comme indicateur visuel, les ports USB 3.0 sont souvent codés en bleu.\u003cbr\u003e\u003cbr\u003eLes concentrateurs USB ne sont pas pris en charge. Les cartes d'extension USB, même si elles répondent formellement aux spécifications High Speed ou Super Speed, ne sont pas recommandées. Elles sont souvent configurées architecturale-ment comme des concentrateurs USB et peuvent entraîner des erreurs de transfert intermittentes difficiles à diagnostiquer.\u003cbr\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Système IPA double avec deux têtes","offer_id":42267583152218,"sku":"SU-IPA2","price":22197.5,"currency_code":"USD","in_stock":true},{"title":"Système IPA avec tête","offer_id":42267583184986,"sku":"SU-IPA","price":17231.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ipa_dipa_lg_1_5bd1743b-856a-41c7-8862-4f1e9e17204b.jpg?v=1766414954"},{"product_id":"iso-80-isolated-differential-amplifier-with-active-probe","title":"Amplificateur différentiel isolé avec sonde active","description":"\u003c!-- section:details --\u003e\n\u003cp\u003e\u003ca href=\"\/fr\/blog\/post\/wpi-s-low-noise-amplifiers-outperform-cheap-imitations\"\u003eDécouvrez ce que vous devez savoir avant d'acheter un amplificateur.\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eExcellente performance d'enregistrement pour les potentiels d'action nerveux extracellulaires\u003c\/h2\u003e\n\u003ch2\u003eCaractéristiques\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAlimenté par batterie, rechargeable\u003c\/li\u003e\n\u003cli\u003eFiltrage passe-haut et passe-bas\u003c\/li\u003e\n\u003cli\u003eTête distante active\u003c\/li\u003e\n\u003cli\u003eAmplification uniquement en courant alternatif\u003c\/li\u003e\n\u003cli\u003eFonction de test d'impédance d'électrode\u003c\/li\u003e\n\u003cli\u003eGénération de courant d'électrode avec sélection de polarité\u003c\/li\u003e\n\u003cli\u003ePositionnement de sortie variable\u003c\/li\u003e\n\u003cli\u003eLa sonde de remplacement ISO-80P ne nécessite pas l'envoi de l'ISO-80 pour étalonnage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLe kit de démarrage comprend 2-CBL102, 2-5469, 2-13388, 3294, 2033, 2034, 2-2035, 2-M3301EH, 5470, EP1.\u003c\/p\u003e\n\u003ch2\u003eAvantages\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAlimentation DC ultra silencieuse\u003c\/li\u003e\n\u003cli\u003eFaible susceptibilité intrinsèque aux boucles de masse\u003c\/li\u003e\n\u003cli\u003eRapport signal sur bruit élevé grâce à la tête distante\u003c\/li\u003e\n\u003cli\u003eEmpreinte réduite\u003c\/li\u003e\n\u003cli\u003eCourant de stimulation\/marquage histologique\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAmplification des bio-potentiels avec microélectrodes métalliques\u003c\/li\u003e\n\u003cli\u003ePotentiels de champ sur tranches cérébrales\u003c\/li\u003e\n\u003cli\u003eEAG (Électroantennogramme)\u003c\/li\u003e\n\u003cli\u003eERG (Électrorétinogramme)\u003c\/li\u003e\n\u003cli\u003eSurveillance des potentiels d'action nerveux extracellulaires\u003c\/li\u003e\n\u003cli\u003eUtilisé pour le marquage cellulaire, la stimulation ou le nettoyage des électrodes\u003c\/li\u003e\n\u003cli\u003e\nEnregistrement cortical \u003cem\u003ein vivo\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKit de démarrage\u003c\/h2\u003e\n\u003cp\u003eInclus avec l'ISO-80, un kit de démarrage contenant les accessoires suivants nécessaires pour la recherche électrophysiologique de base avec électrodes métalliques :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCBL102 Câble, BNC vers prise 3,5 mm 6 pieds (2 m) (deux)\u003c\/li\u003e\n\u003cli\u003e5469 Adaptateur, mini-banana vers prise 0,031 (deux)\u003c\/li\u003e\n\u003cli\u003e13388 Adaptateur, mini-banana vers prise 2 mm (deux)\u003c\/li\u003e\n\u003cli\u003e3294 Câble, pince de terre vers câble, 3 pieds.\u003c\/li\u003e\n\u003cli\u003e2033 Connecteur mini-banana, noir\u003c\/li\u003e\n\u003cli\u003e2034 Connecteur mini-banana, rouge\u003c\/li\u003e\n\u003cli\u003e2035 Connecteur mini-banana soudable à tourelle (deux)\u003c\/li\u003e\n\u003cli\u003ePastille EP1 Ag\/AgCl (câble de 70 mm) diamètre 1 mm x 2,5 mm de long\u003c\/li\u003e\n\u003cli\u003eSupport d'électrode M3301EH, 14 cm (deux)\u003c\/li\u003e\n\u003cli\u003e5470 prise de 0,031 pouce sur câble de 12 pouces (paquet de 4)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications \u003c\/h2\u003e\n\u003cp\u003ePlusieurs applications sont disponibles avec une variété d'options. Ici, vous pouvez voir deux configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATION DIFFÉRENTIELLE POUR ÉLECTRODES MÉTALLIQUES \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDans cette configuration, des électrodes métalliques sont utilisées avec un amplificateur différentiel. Ici, un DAM80 est présenté, mais vous pouvez facilement le remplacer par un DAM50 (avec 5489), ISO-DAM8A (avec 74040) ou ISO-80.\u003c\/p\u003e\n\u003cp\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/damsetup2_8a2961a4-1f39-49ef-ab00-60e275e65aeb.jpg?v=1765946604\" alt=\"Application différentielle pour électrodes métalliques\" width=\"496\" height=\"330\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ISO-80-Differential-application_6864d541-4bcb-4b2a-9cd9-3a3ce4ee6307.jpg?v=1765946610\" alt=\"Configuration d'application différentielle ISO-80\" width=\"85%\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ISO-80-optional-differential-application_7a67ab31-386d-4b3a-a88c-a0a0f42ff0ac.jpg?v=1765946615\" alt=\"Configuration d'application différentielle avec ISO-80\" width=\"75%\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATIONS EXTRACELLULAIRES UTILISANT DU VERRE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePour les rares cas d'utilisation d'amplificateurs extracellulaires avec du verre, vous pouvez utiliser la configuration montrée ci-dessous. Dans cette configuration, un DAM80 est présenté, mais vous pouvez facilement remplacer par un ISODAM8A (avec 74040) ou ISO-80. De même, cette configuration montre la poignée 2505 (1\/4\" - 6,3 mm), mais si vous avez un micromanipulateur plus petit, vous pourriez avoir besoin de la poignée 5444 (3\/16\" - 4,8 mm). Dans cette illustration, MEH7W-10 est utilisé, mais n'importe quelle taille de verre MEH7W peut être utilisée. (MEH7W-10 est du verre de 1,0 mm, MEH7W-12 est du verre de 1,2 mm, MEH7W-15 est du verre de 1,5 mm et MEH7W-20 est du verre de 2,0 mm.) EP2 est utilisé pour la mise à la terre dans l'illustration.\u003c\/p\u003e\n\u003cp\u003ePour les applications à extrémité unique, un adaptateur de fil 2033 sur la prise noire peut être connecté au câble 3294. La pointe utilisée dépend de vos besoins spécifiques. Dans l'illustration, TIP1TW1 est suggéré. NOTEZ que le verre n'est pas montré dans l'illustration ci-dessous. \u003cspan style=\"font-size: 12pt; line-height: 1.3em;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"margin: 5px; width: 469px; height: 418px;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/damsetup1_45eab984-e1ff-407c-b1cd-2933fc4572f4.jpg?v=1765946621\" alt=\"Applications extracellulaires utilisant du verre\" width=\"469\" height=\"418\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ISO-80-single-ended-application_4ec40597-4d80-4e2a-8b62-d2ca8874bcb8.jpg?v=1765946627\" alt=\"Application ISO-80 à extrémité unique\" width=\"80%\"\u003e\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ISO-80_IM.pdf\" target=\"_self\"\u003eManuel ISO-80\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRésistance d’entrée\u003c\/td\u003e\r\n\u003ctd\u003e10\u003csup\u003e11\u003c\/sup\u003eΩ, mode commun et différentiel\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eCourant de fuite d'entrée\u003c\/td\u003e\r\n\u003ctd\u003e50 pA, max.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAmplification\u003c\/td\u003e\r\n\u003ctd\u003ex10\u003csup\u003e2\u003c\/sup\u003e, x10\u003csup\u003e3\u003c\/sup\u003e, x10\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eRapport de rejet du mode commun\u003c\/td\u003e\r\n\u003ctd\u003e100 dB typ. @ 50\/60 Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSignal d'entrée de bruit équivalent\u003c\/td\u003e\r\n\u003ctd\u003e0,4 µV rms (0,1-100 Hz) 2,0 µV rms (1 Hz - 10 kHz)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eRéglages du filtre : basse fréquence\u003c\/td\u003e\r\n\u003ctd\u003e5, 10, 100, 300 Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRéglages du filtre : haute fréquence\u003c\/td\u003e\r\n\u003ctd\u003e100 Hz, 1, 3, 10 kHz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eAmplitude maximale de sortie de tension\u003c\/td\u003e\r\n\u003ctd\u003e±8 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ePlage d'impédance de l'électrode\u003c\/td\u003e\r\n\u003ctd\u003e100 kΩ - 10 MΩ @ 300Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eCourant de stimulation\u003c\/td\u003e\r\n\u003ctd\u003e0 à ±20 µA (courant constant)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTension maximale de STIMULATION\u003c\/td\u003e\r\n\u003ctd\u003e±15 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eTension maximale de l'électrode\u003c\/td\u003e\r\n\u003ctd\u003e±40 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAffichage\u003c\/td\u003e\r\n\u003ctd\u003eÉcran LCD 3,5 chiffres\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eTEST DE LA PILE\u003c\/td\u003e\r\n\u003ctd\u003eAffichage de batterie faible\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAlimentation\u003c\/td\u003e\r\n\u003ctd\u003eDeux batteries Ni-MH 9 V \u0026amp; chargeur fournis\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003ePOIDS D'EXPÉDITION\u003c\/td\u003e\r\n\u003ctd\u003e4 lb. (1,8 kg)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42272862208090,"sku":"ISO-80","price":3750.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/iso-80_2_37987a43-ec63-417a-b2f5-da9b815b074a.jpg?v=1766398221"},{"product_id":"sys-dam50-dam50-extracellular-amplifier","title":"Amplificateur extracellulaire DAM50","description":"\u003c!-- section:details --\u003e\n\u003cp\u003eConsultez la \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/DAM_DS.pdf\"\u003efiche technique\u003c\/a\u003e actuelle.\u003c\/p\u003e\n\u003cp\u003eDécouvrez ce que vous devez \u003ca href=\"\/fr\/blog\/post\/wpi-s-low-noise-amplifiers-outperform-cheap-imitations\"\u003esavoir avant d'acheter un amplificateur\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eUne gamme d'amplificateurs à très faible bruit fonctionnant sur batterie\u003c\/h2\u003e\n\u003ch2\u003eCaractéristiques\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAlimenté par batterie pour éliminer le bruit secteur\u003c\/li\u003e\n\u003cli\u003eFiltrage passe-haut et passe-bas\u003c\/li\u003e\n\u003cli\u003eFonctionnement à extrémité unique ou différentiel\u003c\/li\u003e\n\u003cli\u003eAmplification DC\/AC\u003c\/li\u003e\n\u003cli\u003ePositionnement de sortie variable\u003c\/li\u003e\n\u003cli\u003eConstruit avec des composants de haute qualité pour assurer un bruit intrinsèque (shot) minimal\u003c\/li\u003e\n\u003cli\u003ePortable\u003c\/li\u003e\n\u003cli\u003eMontable en rack\u003c\/li\u003e\n\u003cli\u003eLe pack DAM50 inclut désormais le câble d'électrode métallique blindé 300647 et un câble modulaire blindé.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAvantages\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBruit interne très faible\u003c\/li\u003e\n\u003cli\u003eAlimentation DC ultra silencieuse — pas de AC nécessaire\u003c\/li\u003e\n\u003cli\u003eFaible susceptibilité intrinsèque aux boucles de masse\u003c\/li\u003e\n\u003cli\u003eFaible encombrement\u003c\/li\u003e\n\u003cli\u003eRentable\u003c\/li\u003e\n\u003cli\u003eProtection contre les décharges électrostatiques !\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAmplification des biopotentiels à partir d'électrodes métalliques\u003c\/li\u003e\n\u003cli\u003eStimulation de champ de tranche cérébrale\u003c\/li\u003e\n\u003cli\u003eEAG (Électroantennogramme)\u003c\/li\u003e\n\u003cli\u003eERG (Électrorétinogramme)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRéduction du bruit avec amplification différentielle\u003c\/h2\u003e\n\u003cp\u003eL'amplification différentielle est d'une grande importance en enregistrement bioélectrique pour réduire l'effet toujours présent des interférences de bruit provenant de l'induction du réseau électrique. Un amplificateur différentiel bien conçu diminuera significativement le bruit du réseau (secteur). Il est essentiel que la préparation soit connectée avec une électrode à une bonne terre électrique ainsi qu'au fil de mise à la terre du DAM50 lui-même. Cela devrait avoir pour effet de réduire considérablement le potentiel induit électrostatiquement. En plus de la terre de la préparation, deux connexions d'entrée différentielles doivent être réalisées via des électrodes appropriées appliquées au site d'enregistrement afin d'enregistrer de manière optimale une différence de potentiel bioélectrique.\u003c\/p\u003e\n\u003ch2\u003eTableau comparatif des caractéristiques\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #0081c2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eDAM50\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eDAM80\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eMode d'entrée\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eAC\/DC\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration d'entrée\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eDifférentiel\/à extrémité unique\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eDifférentiel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003ePlage de gain\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e100-10 000 (AC)\u003cbr\u003e10-1 000 (DC)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e100 - 10 000 (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiltres haut\/bas\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eOui\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eOui\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eContrôle de position de décalage\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eOui\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eOui\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGénérateur de courant\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eNon\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eOui\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eTête active distante\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eNon\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eOui\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnexion de sortie\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBNC\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eMini jack 3,5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eConnexion d'entrée standard\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003efil non terminé\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eMini banane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlimentation\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e(2) piles alcalines 9V\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e(2) piles alcalines 9V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e      \u003c\/p\u003e\n\u003ch2\u003eApplications différentielles pour électrodes métalliques\u003c\/h2\u003e\n\u003cp\u003eLes images ci-dessous montrent deux applications pour les électrodes métalliques.  \u003c\/p\u003e\n\u003cp\u003eDans ce premier exemple, une pastille d'électrode scellée RC1T Ag\/AgCl est câblée au câble de l'amplificateur. Cela montre également une configuration différentielle.\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"500\" width=\"500\" alt=\"DAM50\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/DAM50_Aa01_cc0dd12a-941d-47e2-91dd-a76af6401480.jpg?v=1765947822\"\u003e\u003c\/p\u003e\n\u003cp\u003eCe deuxième exemple montre une pastille d'électrode argent\/chlorure d'argent EP2 connectée à l'adaptateur d'amplificateur 5389. Cela montre une configuration différentielle. L'EP2 est adaptée pour une application crânienne chez la souris. Pour cela, elle nécessite un fil d'extension 3294 pour la connecter à l'adaptateur 5389.\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"500\" width=\"500\" alt=\"Dam50\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/DAM50_Ba01_6829c3a7-86d8-49dc-af3e-7d0aa3ffb495.jpg?v=1765947828\"\u003e\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/dam50-im-082208.pdf\"\u003eManuel d'instructions DAM50\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eIMPÉDANCE D'ENTRÉE\u003c\/td\u003e\r\n\u003ctd\u003e10\u003csup\u003e12\u003c\/sup\u003e Ω, mode commun et différentiel\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eCOURANT DE FUITE D'ENTRÉE\u003c\/td\u003e\r\n\u003ctd\u003e50 pA (typique)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSIGNAL DIFFÉRENTIEL DC MAX.\u003c\/td\u003e\r\n\u003ctd\u003e±2,5 V (DAM 50)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eGAIN\u003c\/td\u003e\r\n\u003ctd\u003eAC : 100x, 1000x, 10000x, DC : 10x, 100x, 1000x (DAM50)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRAPPORT DE RÉJECTION DU MODE COMMUN\u003c\/td\u003e\r\n\u003ctd\u003e100 dB @ 50\/60 Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eCAPACITANCE D’ENTRÉE\u003c\/td\u003e\r\n\u003ctd\u003e20 pF\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBRUIT MODE AC\u003c\/td\u003e\r\n\u003ctd\u003e0,4 μV RMS (2uV p-p) 0,1-100 Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eBRUIT MODE AC\u003c\/td\u003e\r\n\u003ctd\u003e2,6 μV RMS (10uV p-p) 1 Hz-10 kHz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBRUIT MODE DC (DAM50)\u003c\/td\u003e\r\n\u003ctd\u003e(DAM50) 7,5uV RMS (30uV p-p) 3-10 kHz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eRÉGLAGES DU FILTRE DE BANDE PASSANTE : Mode AC\u003c\/td\u003e\r\n\u003ctd\u003eBasse fréquence, 0,1, 1, 10, 300 Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRÉGLAGES DU FILTRE DE BANDE PASSANTE : Mode DC (DAM50)\u003c\/td\u003e\r\n\u003ctd\u003eHaute fréquence, 0,1, 1, 3, 10 kHz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eCONNECTEURS DE SORTIE\u003c\/td\u003e\r\n\u003ctd\u003eBNC\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAMPLITUDE DE TENSION DE SORTIE\u003c\/td\u003e\r\n\u003ctd\u003e±8 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eIMPÉDANCE DE SORTIE\u003c\/td\u003e\r\n\u003ctd\u003e470 Ω\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTEST DE PILE\u003c\/td\u003e\r\n\u003ctd\u003eTon audible\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eSIGNAL DE CALIBRATION\u003c\/td\u003e\r\n\u003ctd\u003eOnde carrée 10 Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ePOSITION\u003c\/td\u003e\r\n\u003ctd\u003eEnviron 250 mV\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eCOMMANDE EXTERNE\u003c\/td\u003e\r\n\u003ctd\u003eTension d’entrée ±10 V commandes\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eForme d’onde de courant AC ou DC\u003c\/td\u003e\r\n\u003ctd\u003eAmplitude max ±50μA @ 200 kΩ\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003ePILE(S)\u003c\/td\u003e\r\n\u003ctd\u003e2 x 9 V alcalines (incluses)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDIMENSIONS : DAM50\u003c\/td\u003e\r\n\u003ctd\u003e8 x 4 x 1,75 po (20,3 x 10,2 x 4,4 cm)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003ePOIDS D’EXPÉDITION\u003c\/td\u003e\r\n\u003ctd\u003e3,5 lb (1,6 kg)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003eLes graphiques de bande passante suivants pour le DAM50 montrent la réponse de l’amplificateur lorsque différents filtres et gains sont utilisés. Pour des images plus grandes, cliquez sur les vignettes ci-dessous. \u003c\/p\u003e\r\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/dam50_graph005.jpg\"\u003e\u003cimg style=\"margin: 5px;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/dam50_graph005sm.jpg\" alt=\"Graphiques de bande passante pour le DAM50\" width=\"288\" height=\"182\"\u003e\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cem\u003eGAINS : Ce graphique montre la fréquence de coupure standard à -3 dB à \u003c\/em\u003e la bande passante maximale du filtre.\u003c\/p\u003e\r\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/dam50_graph004.jpg\"\u003e\u003cimg style=\"margin: 5px;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/dam50_graph004sm.jpg\" alt=\"La fréquence standard à -3 dB\" width=\"288\" height=\"178\"\u003e\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cem\u003eFILTRES : Divers filtres passe-bas et passe-haut ont été appliqués au réglage de gain AC x1000 pour montrer la bande passante et l’amplificateur DAM50 réel. \u003c\/em\u003e\u003c\/p\u003e\n\u003c!-- \/section:specifications --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKim, E. Y., \u0026amp; Virginia, W. (n.d.). Effet de l’hormone de croissance sur la fonction synaptique hippocampique pendant la privation de sommeil par.\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003efull-text. (n.d.).\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eDai, J., Brooks, D. I., \u0026amp; Sheinberg, D. L. (n.d.). Informations supplémentaires - Le système d’optogénétique et de microstimulation électrique biaise systématiquement le choix visuospatial chez les primates.\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eŠkorjanc, A., \u0026amp; Belušič, G. (n.d.). Comment nous enseignons : projets de recherche en classe et en laboratoire - Étude du flux sanguin et de l’effet des substances vasoactives dans les vaisseaux cutanés de Xenopus laevis.\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eLiu, Y., Wang, Y., Zhu, G., Sun, J., Bi, X., \u0026amp; Baudry, M. (2016). Un inhibiteur sélectif de la calpaïne-2 améliore l’apprentissage et la mémoire en prolongeant l’activation d’ERK. \u003ci\u003eNeuropharmacology\u003c\/i\u003e, \u003ci\u003e105\u003c\/i\u003e, 471–477. \u003ca href=\"http:\/\/doi.org\/10.1016\/j.neuropharm.2016.02.022\"\u003ehttp:\/\/doi.org\/10.1016\/j.neuropharm.2016.02.022\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eZtaou, S., Maurice, N., Camon, J., Guiraudie-Capraz, G., Kerkerian-Le Goff, L., Beurrier, C., … Amalric, M. (2016). Implication des interneurones cholinergiques striataux et des récepteurs muscariniques M1 et M4 dans les symptômes moteurs de la maladie de Parkinson. \u003ci\u003eJournal of Neuroscience\u003c\/i\u003e, \u003ci\u003e36\u003c\/i\u003e(35).\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKentish, S. S. J., Frisby, C. L., Kritas, S., Li, H., Hatzinikolas, G., O’Donnell, T. A., … Ahern, G. (2015). Canaux TRPV1 et signalisation vagale gastrique afférente chez des souris maigres et obèses induites par un régime riche en graisses. \u003ci\u003ePloS One\u003c\/i\u003e, \u003ci\u003e10\u003c\/i\u003e(8), e0135892. \u003ca href=\"http:\/\/doi.org\/10.1371\/journal.pone.0135892\"\u003ehttp:\/\/doi.org\/10.1371\/journal.pone.0135892\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eBlauvelt, D. G., Sato, T. F., Wienisch, M., \u0026amp; Murthy, V. N. (2013). Activité spatiotemporelle distincte dans les neurones principaux du bulbe olfactif de souris à l’état anesthésié et éveillé. \u003ci\u003eFrontiers in Neural Circuits\u003c\/i\u003e, \u003ci\u003e7\u003c\/i\u003e. \u003ca href=\"http:\/\/doi.org\/10.3389\/fncir.2013.00046\"\u003ehttp:\/\/doi.org\/10.3389\/fncir.2013.00046\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eBlaise, J. H. (2013). Potentialisation à long terme de la synapse du chemin perforant au gyrus denté chez des souris en liberté. \u003ci\u003eJournal of Visualized Experiments\u003c\/i\u003e, (81), e50642. \u003ca href=\"http:\/\/doi.org\/10.3791\/50642\"\u003ehttp:\/\/doi.org\/10.3791\/50642\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eWang, H., Siddharthan, V., Kesler, K. K., Hall, J. O., Motter, N. E., Julander, J. G., \u0026amp; Morrey, J. D. (2013). L’insuffisance respiratoire neurologique fatale est fréquente parmi les encéphalites virales. \u003ci\u003eThe Journal of Infectious Diseases\u003c\/i\u003e, \u003ci\u003e208\u003c\/i\u003e(4), 573–83. \u003ca href=\"http:\/\/doi.org\/10.1093\/infdis\/jit186\"\u003ehttp:\/\/doi.org\/10.1093\/infdis\/jit186\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eZhang, Q.-X., Lu, R.-W., Curcio, C. A., Yao, X.-C., DC., H., SE., N., … PN, D. (2012). Identification in vivo par signal optique intrinsèque confocal de dysfonctionnements rétiniens localisés. \u003ci\u003eInvestigative Opthalmology \u0026amp; Visual Science\u003c\/i\u003e, \u003ci\u003e53\u003c\/i\u003e(13), 8139. \u003ca href=\"http:\/\/doi.org\/10.1167\/iovs.12-10732\"\u003ehttp:\/\/doi.org\/10.1167\/iovs.12-10732\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eBadsha, F., Kain, P., Prabhakar, S., Sundaram, S., Padinjat, R., Rodrigues, V., \u0026amp; Hasan, G. (2012). Les mutants des canaux TRPC de Drosophila réduisent la sensibilité olfactive au dioxyde de carbone. \u003ci\u003ePloS One\u003c\/i\u003e, \u003ci\u003e7\u003c\/i\u003e(11), e49848. \u003ca href=\"http:\/\/doi.org\/10.1371\/journal.pone.0049848\"\u003ehttp:\/\/doi.org\/10.1371\/journal.pone.0049848\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKonow, N., Azizi, E., \u0026amp; Roberts, T. J. (2012). Atténuation de la puissance musculaire par le tendon lors de la dissipation d’énergie. \u003ci\u003eProceedings. Biological Sciences \/ The Royal Society\u003c\/i\u003e, \u003ci\u003e279\u003c\/i\u003e(1731), 1108–13. \u003ca href=\"http:\/\/doi.org\/10.1098\/rspb.2011.1435\"\u003ehttp:\/\/doi.org\/10.1098\/rspb.2011.1435\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eChen, S., Mohajerani, M. H., Xie, Y., \u0026amp; Murphy, T. H. (2012). Analyse optogénétique de l’excitabilité neuronale pendant l’ischémie globale révélant des déficits sélectifs dans le traitement sensoriel après reperfusion dans le cortex de souris. \u003ci\u003eThe Journal of Neuroscience : The Official Journal of the Society for Neuroscience\u003c\/i\u003e, \u003ci\u003e32\u003c\/i\u003e(39), 13510–9. \u003ca href=\"http:\/\/doi.org\/10.1523\/JNEUROSCI.1439-12.2012\"\u003ehttp:\/\/doi.org\/10.1523\/JNEUROSCI.1439-12.2012\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eMorrey, J. D., Siddharthan, V., Wang, H., Hall, J. O., Motter, N. E., Skinner, R. D., \u0026amp; Skirpstunas, R. T. (2010). Suppression neurologique des électromyogrammes du diaphragme chez des hamsters infectés par le virus du Nil occidental. \u003ci\u003eJournal of Neurovirology\u003c\/i\u003e, \u003ci\u003e16\u003c\/i\u003e(4), 318–329. \u003ca href=\"http:\/\/doi.org\/10.3109\/13550284.2010.501847\"\u003ehttp:\/\/doi.org\/10.3109\/13550284.2010.501847\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eBrundage, C. M., \u0026amp; Taylor, B. E. (2010). Neuroplasticité de la réponse ventilatoire centrale hypercapnique : altération induite par un tératogène et récupération ultérieure pendant le développement. \u003ci\u003eDevelopmental Neurobiology\u003c\/i\u003e, \u003ci\u003e70\u003c\/i\u003e(10), 726–35. \u003ca href=\"http:\/\/doi.org\/10.1002\/dneu.20806\"\u003ehttp:\/\/doi.org\/10.1002\/dneu.20806\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKim, E., Grover, L. M., Bertolotti, D., \u0026amp; Green, T. L. (2010). L'hormone de croissance restaure la fonction synaptique hippocampique après privation de sommeil. \u003ci\u003eAmerican Journal of Physiology. Regulatory, Integrative and Comparative Physiology\u003c\/i\u003e, \u003ci\u003e298\u003c\/i\u003e(6), R1588-96. \u003ca href=\"http:\/\/doi.org\/10.1152\/ajpregu.00580.2009\"\u003ehttp:\/\/doi.org\/10.1152\/ajpregu.00580.2009\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKavlie, R. G., Kernan, M. J., \u0026amp; Eberl, D. F. (2010). L'audition chez Drosophila nécessite TilB, une protéine conservée associée à la motilité ciliaire. \u003ci\u003eGenetics\u003c\/i\u003e, \u003ci\u003e185\u003c\/i\u003e(1), 177–88. \u003ca href=\"http:\/\/doi.org\/10.1534\/genetics.110.114009\"\u003ehttp:\/\/doi.org\/10.1534\/genetics.110.114009\u003c\/a\u003e \u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eLenti, L., Domoki, F., Gáspár, T., Snipes, J. A., Bari, F., \u0026amp; Busija, D. W. (2009). Le N-Méthyl-d-Aspartate induit une hyperémie corticale par des mécanismes dépendants et indépendants de la dépression corticale propagée chez le rat. \u003ci\u003eMicrocirculation\u003c\/i\u003e, \u003ci\u003e16\u003c\/i\u003e(7), 629–639. \u003ca href=\"http:\/\/doi.org\/10.1080\/10739680903131510\"\u003ehttp:\/\/doi.org\/10.1080\/10739680903131510\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eSu, C.-K., Ho, C.-M., Kuo, H.-H., Wen, Y.-C., \u0026amp; Chai, C.-Y. (2009). Expression de c-Fos corrélée au système sympathique dans la moelle épinière de rat nouveau-né in vitro. \u003ci\u003eJournal of Biomedical Science\u003c\/i\u003e, \u003ci\u003e16\u003c\/i\u003e(1), 44. \u003ca href=\"http:\/\/doi.org\/10.1186\/1423-0127-16-44\"\u003ehttp:\/\/doi.org\/10.1186\/1423-0127-16-44\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eBrundage, C. M., \u0026amp; Taylor, B. E. (2009). Le moment et la durée de l'exposition au nicotine pendant le développement contribuent à l'atténuation de la réponse neuroventilatoire hypercapnique chez le têtard. \u003ci\u003eDevelopmental Neurobiology\u003c\/i\u003e, \u003ci\u003e69\u003c\/i\u003e(7), 451–61. \u003ca href=\"http:\/\/doi.org\/10.1002\/dneu.20720\"\u003ehttp:\/\/doi.org\/10.1002\/dneu.20720\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eOrem, N. R., Xia, L., \u0026amp; Dolph, P. J. (2006). Un rôle essentiel de l'endocytose de la rhodopsine via l'interaction de l'arrestine visuelle avec l'adaptateur AP-2. \u003ci\u003eJournal of Cell Science\u003c\/i\u003e, \u003ci\u003e119\u003c\/i\u003e(Pt 15), 3141–8. \u003ca href=\"http:\/\/doi.org\/10.1242\/jcs.03052\"\u003ehttp:\/\/doi.org\/10.1242\/jcs.03052\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eMarkham, M. R., \u0026amp; Stoddard, P. K. (2005). L'hormone adrénocorticotrope renforce la masculinité d'un signal de communication électrique en modulant la forme d'onde et le timing des potentiels d'action au sein des cellules individuelles. \u003ci\u003eThe Journal of Neuroscience : The Official Journal of the Society for Neuroscience\u003c\/i\u003e, \u003ci\u003e25\u003c\/i\u003e(38), 8746–54. \u003ca href=\"http:\/\/doi.org\/10.1523\/JNEUROSCI.2809-05.2005\"\u003ehttp:\/\/doi.org\/10.1523\/JNEUROSCI.2809-05.2005\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eCartford, M. C. (2004). La noradrénaline cérébelleuse module l'apprentissage du conditionnement classique du clignement retardé : preuve d'une signalisation post-synaptique via la PKA. \u003ci\u003eLearning \u0026amp; Memory\u003c\/i\u003e, \u003ci\u003e11\u003c\/i\u003e(6), 732–737. \u003ca href=\"http:\/\/doi.org\/10.1101\/lm.83104\"\u003ehttp:\/\/doi.org\/10.1101\/lm.83104\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eJonker, D. M., Vermeij, D. A. C., Edelbroek, P. M., Voskuyl, R. A., Piotrovsky, V. K., \u0026amp; Danhof, M. (2003). Analyse pharmacodynamique de l'interaction entre la tiagabine et le midazolam avec un modèle allostérique intégrant la transduction du signal. \u003ci\u003eEpilepsia\u003c\/i\u003e, \u003ci\u003e44\u003c\/i\u003e(3), 329–338. \u003ca href=\"http:\/\/doi.org\/10.1046\/j.1528-1157.2003.37802.x\"\u003ehttp:\/\/doi.org\/10.1046\/j.1528-1157.2003.37802.x\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003evan den Pol, A. N., Ghosh, P. K., Liu, R., Li, Y., Aghajanian, G. K., \u0026amp; Gao, X.-B. (2002). L'hypocrétine (orexine) augmente l'activité neuronale et la synchronie cellulaire dans le locus coeruleus en développement chez la souris exprimant la GFP. \u003ci\u003eThe Journal of Physiology\u003c\/i\u003e, \u003ci\u003e541\u003c\/i\u003e(1), 169–185. \u003ca href=\"http:\/\/doi.org\/10.1113\/jphysiol.2002.017426\"\u003ehttp:\/\/doi.org\/10.1113\/jphysiol.2002.017426\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eRansom, C. B., Ransom, B. R., \u0026amp; Sontheimer, H. (2000). Accumulation extracellulaire de K+ dépendante de l'activité dans le nerf optique du rat : rôle des pompes Na+ gliales et axonales. \u003ci\u003eThe Journal of Physiology\u003c\/i\u003e, \u003ci\u003e522 Pt 3\u003c\/i\u003e, 427–42. Consulté sur \u003ca href=\"http:\/\/www.pubmedcentral.nih.gov\/articlerender.fcgi?artid=2269766\u0026amp;tool=pmcentrez\u0026amp;rendertype=abstract\"\u003ehttp:\/\/www.pubmedcentral.nih.gov\/articlerender.fcgi?artid=2269766\u0026amp;tool=pmcentrez\u0026amp;rendertype=abstract\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eAlloway, P. G., \u0026amp; Dolph, P. J. (1999). Un rôle pour la phosphorylation dépendante de la lumière de l'arrestine visuelle. \u003ci\u003eProceedings of the National Academy of Sciences\u003c\/i\u003e, \u003ci\u003e96\u003c\/i\u003e(11), 6072–6077. \u003ca href=\"http:\/\/doi.org\/10.1073\/pnas.96.11.6072\"\u003ehttp:\/\/doi.org\/10.1073\/pnas.96.11.6072\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eLipchik, G. L., Holroyd, K. A., France, C. R., Kvaal, S. A., Segal, D., Cordingley, G. E., … McCool, H. R. (1996). Mécanismes centraux et périphériques dans la céphalée de tension chronique. \u003ci\u003ePain\u003c\/i\u003e, \u003ci\u003e64\u003c\/i\u003e(3), 467–75. Consulté sur \u003ca href=\"http:\/\/www.pubmedcentral.nih.gov\/articlerender.fcgi?artid=2128054\u0026amp;tool=pmcentrez\u0026amp;rendertype=abstract\"\u003ehttp:\/\/www.pubmedcentral.nih.gov\/articlerender.fcgi?artid=2128054\u0026amp;tool=pmcentrez\u0026amp;rendertype=abstract\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKnuckey, N. W., Palm, D., Primiano, M., Epstein, M. H., \u0026amp; Johanson, C. E. (1995). La N-Acétylcystéine améliore la survie neuronale hippocampique après une ischémie transitoire du cerveau antérieur chez le rat. \u003ci\u003eStroke\u003c\/i\u003e, \u003ci\u003e26\u003c\/i\u003e(2), 305–311. \u003ca href=\"http:\/\/doi.org\/10.1161\/01.STR.26.2.305\"\u003ehttp:\/\/doi.org\/10.1161\/01.STR.26.2.305\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42272907067482,"sku":"SYS-DAM50","price":2100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/dam50-cable_f63449e3-728b-4aa5-8ae4-b8de3c817ee7.png?v=1766399605"},{"product_id":"sys-dam80-extracellular-amplifier-with-active-probe","title":"Amplificateur extracellulaire avec sonde active","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eUne gamme d'amplificateurs extracellulaires à très faible bruit, alimentés par batterie\u003c\/h2\u003e\n\u003cp\u003eLe kit de démarrage DAM80 comprend : 2-CBL102, 5469, 2-13388, 3294, 2033, 2034, 2-2035\u003c\/p\u003e\n\u003cp\u003eConsultez la \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/DAM_DS.pdf\"\u003efiche technique\u003c\/a\u003e actuelle.\u003c\/p\u003e\n\u003cp\u003eDécouvrez ce que vous devez \u003ca href=\"\/fr\/blog\/post\/wpi-s-low-noise-amplifiers-outperform-cheap-imitations\"\u003esavoir avant d'acheter un amplificateur\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eCaractéristiques\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAlimenté par batterie pour éliminer le bruit secteur\u003c\/li\u003e\n\u003cli\u003eFiltrage passe-haut et passe-bas\u003c\/li\u003e\n\u003cli\u003eFonctionnement en simple extrémité ou différentiel\u003c\/li\u003e\n\u003cli\u003eAmplification AC uniquement\u003c\/li\u003e\n\u003cli\u003eComprend une tête à faible bruit\u003c\/li\u003e\n\u003cli\u003ePositionnement de sortie variable\u003c\/li\u003e\n\u003cli\u003eConstruit avec des composants de haute qualité pour assurer un bruit intrinsèque (de tir) minimal\u003c\/li\u003e\n\u003cli\u003ePortable\u003c\/li\u003e\n\u003cli\u003eMontable en rack\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAvantages\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBruit interne très faible\u003c\/li\u003e\n\u003cli\u003eAlimentation DC ultra silencieuse — pas de courant alternatif requis\u003c\/li\u003e\n\u003cli\u003eFaible susceptibilité intrinsèque aux boucles de masse\u003c\/li\u003e\n\u003cli\u003eFaible encombrement\u003c\/li\u003e\n\u003cli\u003eRentable\u003c\/li\u003e\n\u003cli\u003eProtection contre les décharges électrostatiques !\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAmplification des biopotentiels à partir d'électrodes métalliques\u003c\/li\u003e\n\u003cli\u003eStimulation de champ sur tranches cérébrales\u003c\/li\u003e\n\u003cli\u003eEAG (Électroantennogramme)\u003c\/li\u003e\n\u003cli\u003eERG (Électrorétinogramme)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eLes amplificateurs de la série \u003cstrong\u003eDAM\u003c\/strong\u003e de WPI sont bien connus comme une référence dans l'industrie pour l'amplification des potentiels extracellulaires. Ces bio-amplificateurs alimentés par batterie sont conçus avec un châssis compact qui permet à l'utilisateur de placer l'unité plus près de la préparation et ainsi minimiser la longueur des câbles, ce qui réduit le bruit. Chaque amplificateur est équipé de filtres haut et bas sélectionnables, ainsi que d'un contrôle de position pour compenser les potentiels galvaniques pouvant se développer pendant l'enregistrement.\u003c\/p\u003e\n\u003cp\u003eLe kit de démarrage (inclus) est montré sur l'image ci-dessous.\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"432\" width=\"576\" alt=\"Le kit de démarrage DAM80 comprend les composants illustrés.\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/dam80kit_992d4f69-2fd4-4886-8b14-9e75dd253c82.jpg?v=1765947842\" style=\"margin: 5px;\"\u003e\u003c\/p\u003e\n\u003ch2\u003eTête active à distance\u003c\/h2\u003e\n\u003cp\u003eLe \u003cstrong\u003eDAM80\u003c\/strong\u003e, un amplificateur AC uniquement, dispose d'une sonde de tête à très faible bruit qui peut être montée sur des micromanipulateurs pour un enregistrement cortical rapproché, ou pour l'enregistrement extracellulaire à partir d'électrodes microélectriques en verre ou en métal à haute impédance. L'unité fournit également un courant commandé pour le marquage des tissus. Le support de microélectrode \u003ca href=\"\/fr\/var-3814-microelectrode-holder-meh7w\"\u003e\u003cstrong\u003eMEH7W-XX\u003c\/strong\u003e\u003c\/a\u003e (vendu séparément) est recommandé pour les microélectrodes en verre.\u003c\/p\u003e\n\u003ch2\u003eGénération de courant\u003c\/h2\u003e\n\u003cp\u003eLe DAM80 est parfait pour la génération de courant commandée ou manuelle pour le marquage histologique, l'iontophorèse ou la stimulation cellulaire. Il inclut une tête active à distance à très faible bruit, utile pour l'amplification à très haute impédance utilisant des électrodes en verre ou en métal.\u003c\/p\u003e\n\u003ch2\u003ePortabilité\u003c\/h2\u003e\n\u003cp\u003eLes amplificateurs de la série \u003cstrong\u003eDAM\u003c\/strong\u003e peuvent être utilisés comme unités autonomes sur n'importe quelle surface plane, ou avec un matériel de fixation par pince optionnel pour les placer commodément dans la zone de travail. Alternativement, une paire d'amplificateurs peut être montée dans une baie d'équipement standard avec un kit de montage en rack (#\u003cstrong\u003e3484\u003c\/strong\u003e). Une variété d'accessoires de connexion est disponible pour configurer votre application. \u003c\/p\u003e\n\u003ch2\u003eTableau comparatif des caractéristiques\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #0081c2;\"\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eDAM50\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eDAM80\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eMode d'entrée\u003c\/td\u003e\n\u003ctd\u003eAC\/DC\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration d'entrée\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eDifférentiel\/à extrémité unique\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eDifférentiel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003ePlage de gain\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e100-10 000 (AC)\u003cbr\u003e10-1 000 (DC)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e100 - 10 000 (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiltres haut\/bas\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eOui\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eOui\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eContrôle de position de décalage\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eOui\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eOui\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGénérateur de courant\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eNon\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eOui\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eTête active à distance\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eNon\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eOui\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnexion de sortie\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBNC\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eMini jack 3,5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eConnexion d'entrée standard\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003efil non terminé\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eMini banane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlimentation électrique\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e(2) piles alcalines 9V\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e(2) piles alcalines 9V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"contentcontainer\" id=\"appnotescontainer\"\u003e\n\u003cp\u003ePlusieurs applications sont disponibles avec une variété d'options. Ici, vous pouvez voir deux configurations.\u003c\/p\u003e\n\u003ch2\u003eApplications différentielles pour électrodes métalliques\u003c\/h2\u003e\n\u003cp\u003eDans cette configuration, des électrodes métalliques sont utilisées avec un amplificateur différentiel. Dans cette configuration, un \u003ca href=\"\/fr\/sys-dam80-extracellular-amplifier-with-active-probe\"\u003e\u003cstrong\u003eDAM80\u003c\/strong\u003e\u003c\/a\u003e est présenté, mais vous pouvez facilement le remplacer par un \u003ca href=\"\/fr\/sys-dam50-dam50-extracellular-amplifier\"\u003e\u003cstrong\u003eDAM50\u003c\/strong\u003e\u003c\/a\u003e (avec \u003ca href=\"\/fr\/5489-optional-probe-for-dam50\"\u003e\u003cstrong\u003e5489\u003c\/strong\u003e\u003c\/a\u003e), \u003cstrong\u003eISO-DAM8A\u003c\/strong\u003e (avec \u003ca href=\"\/fr\/74040-iso-dam8a-active-headstage\"\u003e\u003cstrong\u003e74040\u003c\/strong\u003e\u003c\/a\u003e) ou un \u003ca href=\"\/fr\/iso-80-isolated-differential-amplifier-with-active-probe\"\u003e\u003cstrong\u003eISO-80\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"330\" width=\"496\" alt=\"APPLICATION DIFFÉRENTIELLE POUR ÉLECTRODES MÉTALLIQUES\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/damsetup2_21a259c3-95dc-41ab-923f-28dc4772870e.jpg?v=1765947848\"\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications extracellulaires utilisant des microélectrodes en verre\u003c\/h2\u003e\n\u003cp\u003ePour les rares cas où vous utilisez des amplificateurs extracellulaires avec du verre, vous pouvez utiliser la configuration montrée ci-dessous. Dans cette configuration, un DAM80 est présenté, mais vous pouvez facilement le remplacer par un \u003cstrong\u003eISO-DAM8A\u003c\/strong\u003e (avec \u003ca href=\"\/fr\/74040-iso-dam8a-active-headstage\"\u003e\u003cstrong\u003e74040\u003c\/strong\u003e\u003c\/a\u003e) ou un \u003ca href=\"\/fr\/iso-80-isolated-differential-amplifier-with-active-probe\"\u003e\u003cstrong\u003eISO-80\u003c\/strong\u003e\u003c\/a\u003e. De même, cette configuration montre la poignée \u003ca href=\"\/fr\/2505-electrode-handle-63-mm\"\u003e\u003cstrong\u003e2505\u003c\/strong\u003e\u003c\/a\u003e (1\/4\" - 6,3 mm), mais si vous avez un micromanipulateur plus petit, vous pourriez avoir besoin de la poignée \u003ca href=\"\/fr\/5444-electrode-handle-48-mm\"\u003e\u003cstrong\u003e5444\u003c\/strong\u003e\u003c\/a\u003e (3\/16\" - 4,8 mm). Dans cette illustration, \u003ca rel=\"noopener\" href=\"\/fr\/var-3814-microelectrode-holder-meh7w\" target=\"_blank\"\u003e\u003cstrong\u003eMEH7W-10\u003c\/strong\u003e\u003c\/a\u003e est utilisé, mais n'importe quelle taille de verre \u003ca rel=\"noopener\" href=\"\/fr\/var-3814-microelectrode-holder-meh7w\" target=\"_blank\"\u003e\u003cstrong\u003eMEH7W\u003c\/strong\u003e\u003c\/a\u003e pourrait être utilisée. (\u003ca rel=\"noopener\" href=\"\/fr\/var-3814-microelectrode-holder-meh7w\" target=\"_blank\"\u003e\u003cstrong\u003eMEH7W-10\u003c\/strong\u003e\u003c\/a\u003e correspond à du verre de 1,0 mm, \u003ca rel=\"noopener\" href=\"\/fr\/var-3814-microelectrode-holder-meh7w\" target=\"_blank\"\u003e\u003cstrong\u003eMEH7W-12\u003c\/strong\u003e\u003c\/a\u003e à du verre de 1,2 mm, \u003ca rel=\"noopener\" href=\"\/fr\/var-3814-microelectrode-holder-meh7w\" target=\"_blank\"\u003e\u003cstrong\u003eMEH7W-15\u003c\/strong\u003e\u003c\/a\u003e à du verre de 1,5 mm et \u003ca href=\"\/fr\/var-3814-microelectrode-holder-meh7w\"\u003e\u003cstrong\u003eMEH7W-20\u003c\/strong\u003e\u003c\/a\u003e à du verre de 2,0 mm.) \u003ca href=\"\/fr\/var-2739-ag-agcl-electrode\"\u003e\u003cstrong\u003eEP2\u003c\/strong\u003e\u003c\/a\u003e est utilisé pour la mise à la terre dans l'illustration.\u003c\/p\u003e\n\u003cp\u003ePour les applications à entrée simple, cependant, un adaptateur de fil \u003ca href=\"\/fr\/2033-black-insulated-mini-banana-plug\"\u003e\u003cstrong\u003e2033\u003c\/strong\u003e\u003c\/a\u003e sur la prise du connecteur noir peut être connecté au câble \u003ca href=\"\/fr\/3294-ground-wire-for-dam80-probe\"\u003e\u003cstrong\u003e3294\u003c\/strong\u003e\u003c\/a\u003e. La pointe utilisée dépend de vos besoins spécifiques. Dans l'illustration, \u003ca href=\"\/fr\/var-3564-pre-pulled-glass-pipettes\"\u003e\u003cstrong\u003eTIP1TW1\u003c\/strong\u003e \u003c\/a\u003eétait suggérée. NOTEZ que le verre n'est pas montré dans l'illustration ci-dessous.\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"418\" width=\"469\" alt=\"APPLICATIONS EXTRACELLULAIRES UTILISANT LE VERRE\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/damsetup1_81b0fb71-843c-40ff-a980-343604d34af6.jpg?v=1765947854\" style=\"margin: 5px;\"\u003e\u003c\/p\u003e\n\u003cp\u003e   \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- \/section:details --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/DAM80_IMs.pdf\" target=\"_self\"\u003eManuel d'instructions DAM80\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:specifications --\u003e\n\u003ctable cellpadding=\"2\" cellspacing=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIMPÉDANCE D'ENTRÉE\u003c\/td\u003e\n\u003ctd\u003e10\u003csup\u003e12 \u003c\/sup\u003eΩ, mode commun et différentiel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eCOURANT DE FUITE D'ENTRÉE\u003c\/td\u003e\n\u003ctd\u003e50 pA (typique)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAPPORT DE RÉJECTION DU MODE COMMUN\u003c\/td\u003e\n\u003ctd\u003e100 dB @ 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eCAPACITÉ D'ENTRÉE\u003c\/td\u003e\n\u003ctd\u003e20 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBRUIT EN MODE AC\u003c\/td\u003e\n\u003ctd\u003e0,4 µV RMS (2uV p-p) 0,1-100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eBRUIT EN MODE AC\u003c\/td\u003e\n\u003ctd\u003e2,6 µV RMS (10uV p-p) 1Hz-10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRÉGLAGES FILTRE DE BANDE PASSANTE, Mode AC\u003c\/td\u003e\n\u003ctd\u003eBasse fréquence, 0,1, 1, 10, 300 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eRÉGLAGES FILTRE DE BANDE PASSANTE : Mode AC (DAM80)\u003c\/td\u003e\n\u003ctd\u003eHaute fréquence, 0,1, 1, 3, 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCONNECTEURS DE SORTIE\u003c\/td\u003e\n\u003ctd\u003eConnecteur MiniPhone 3,5 mm sur DAM80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eAMPLITUDE DE TENSION DE SORTIE\u003c\/td\u003e\n\u003ctd\u003e±8V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIMPÉDANCE DE SORTIE\u003c\/td\u003e\n\u003ctd\u003e470 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eTEST DE PILE\u003c\/td\u003e\n\u003ctd\u003eTon audible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSIGNAL DE CALIBRATION\u003c\/td\u003e\n\u003ctd\u003eOnde carrée 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003ePOSITION\u003c\/td\u003e\n\u003ctd\u003eEnviron 250 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSOURCE DE COURANT:DAM80: Générateur continu\u003c\/td\u003e\n\u003ctd\u003e0 à ±50 µA, variable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eCOMMANDE EXTERNE\u003c\/td\u003e\n\u003ctd\u003eTension d'entrée commandes ±10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForme d'onde courant alternatif ou continu\u003c\/td\u003e\n\u003ctd\u003e±50 µA amplitude max. @ 200 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003ePILES\u003c\/td\u003e\n\u003ctd\u003e2 x 9 V alcalines (incluses)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDIMENSIONS:DAM80\u003c\/td\u003e\n\u003ctd\u003e7 x 4 x 1,75 po (17,8 x 10,2 x 4,4 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003ePOIDS D'EXPÉDITION\u003c\/td\u003e\n\u003ctd\u003e3,5 lb (1,6 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:references --\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eDonnelly, W. T., Bartlett, D., \u0026amp; Leiter, J. C. (2016). La sérotonine dans le noyau du tractus solitaire raccourcit le chémoréflexe laryngé chez les rats nouveau-nés anesthésiés. \u003ci\u003eExperimental Physiology\u003c\/i\u003e, \u003ci\u003e101\u003c\/i\u003e(7), 946–961. \u003ca href=\"http:\/\/doi.org\/10.1113\/EP085716\"\u003ehttp:\/\/doi.org\/10.1113\/EP085716\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eFeng, B., Joyce, S. C., \u0026amp; Gebhart, G. F. (2016). Activation optogénétique des afférences mécaniquement insensibles dans le côlon-rectum de souris révèle une chémosensibilité. \u003ci\u003eAmerican Journal of Physiology - Gastrointestinal and Liver Physiology\u003c\/i\u003e, \u003ci\u003e310\u003c\/i\u003e(10).\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKaldenbach, F., Bleckmann, H., \u0026amp; Kohl, T. (2016). Réponses des unités tectales sensibles à l'infrarouge du serpent à sonnette Crotalus atrox aux objets en mouvement. \u003ci\u003eJournal of Comparative Physiology A\u003c\/i\u003e, \u003ci\u003e202\u003c\/i\u003e(6), 389–398. \u003ca href=\"http:\/\/doi.org\/10.1007\/s00359-016-1076-1\"\u003ehttp:\/\/doi.org\/10.1007\/s00359-016-1076-1\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eMustafina, A. N., Koroleva, K. S., Giniatullin, R. A., \u0026amp; Sitdikova, G. F. (2016). Canaux ioniques sensibles aux acides comme cible du sulfure d'hydrogène dans les neurones trigéminés de rat. \u003ci\u003eBioNanoScience\u003c\/i\u003e, 1–3. \u003ca href=\"http:\/\/doi.org\/10.1007\/s12668-016-0237-6\"\u003ehttp:\/\/doi.org\/10.1007\/s12668-016-0237-6\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eOrton, L. D., Papasavvas, C. A., \u0026amp; Rees, A. (2016). Le contrôle du gain commissural améliore la représentation de la localisation sonore dans le mésencéphale. \u003ci\u003eThe Journal of Neuroscience : The Official Journal of the Society for Neuroscience\u003c\/i\u003e, \u003ci\u003e36\u003c\/i\u003e(16), 4470–81. \u003ca href=\"http:\/\/doi.org\/10.1523\/JNEUROSCI.3012-15.2016\"\u003ehttp:\/\/doi.org\/10.1523\/JNEUROSCI.3012-15.2016\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003ePalanca-Castan, N., Laumen, G., Reed, D., \u0026amp; Köppl, C. (2016). La composante d’interaction binaurale chez la chouette effraie (Tyto alba) présente peu de différences avec les données des mammifères. \u003ci\u003eJournal of the Association for Research in Otolaryngology\u003c\/i\u003e, 1–13. \u003ca href=\"http:\/\/doi.org\/10.1007\/s10162-016-0583-7\"\u003ehttp:\/\/doi.org\/10.1007\/s10162-016-0583-7\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eFeng, B., \u0026amp; Gebhart, G. F. (2015). \u0026amp;lt;em\u0026amp;gt;Caractérisation fonctionnelle in vitro\u0026amp;lt;\/em\u0026amp;gt; des terminaisons afférentes colorectales de la souris. \u003ci\u003eJournal of Visualized Experiments\u003c\/i\u003e, (95), e52310–e52310. \u003ca href=\"http:\/\/doi.org\/10.3791\/52310\"\u003ehttp:\/\/doi.org\/10.3791\/52310\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eGholami, M., Moradpour, F., Semnanian, S., Naghdi, N., \u0026amp; Fathollahi, Y. (2015). L’administration chronique de salicylate de sodium améliore la potentialisation à long terme des pics de population après une stimulation en rafale amorcée à fréquence thêta et l’application transitoire de pentylenetetrazol dans les neurones CA1 de l’hippocampe du rat. \u003ci\u003eEuropean Journal of Pharmacology\u003c\/i\u003e, \u003ci\u003e767\u003c\/i\u003e, 165–174. \u003ca href=\"http:\/\/doi.org\/10.1016\/j.ejphar.2015.10.021\"\u003ehttp:\/\/doi.org\/10.1016\/j.ejphar.2015.10.021\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKim, Y.-J., \u0026amp; Kang, T.-C. (2015). Le rôle de TRPC6 dans la susceptibilité aux crises et les dommages neuronaux liés aux crises dans le gyrus denté du rat. \u003ci\u003eNeuroscience\u003c\/i\u003e, \u003ci\u003e307\u003c\/i\u003e, 215–230. \u003ca href=\"http:\/\/doi.org\/10.1016\/j.neuroscience.2015.08.054\"\u003ehttp:\/\/doi.org\/10.1016\/j.neuroscience.2015.08.054\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKulthinee, S., Wyss, J. M., \u0026amp; Roysommuti, S. (2015). La supplémentation en taurine prévient l’effet néfaste d’une consommation élevée de sucre sur le contrôle de la pression artérielle après ischémie\/reperfusion cardiaque chez la rate. \u003ci\u003eAdvances in Experimental Medicine and Biology\u003c\/i\u003e, \u003ci\u003e803\u003c\/i\u003e, 597–611. \u003ca href=\"http:\/\/doi.org\/10.1007\/978-3-319-15126-7_48\"\u003ehttp:\/\/doi.org\/10.1007\/978-3-319-15126-7_48\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eBouabid, S., Delaville, C., De Deurwaerdère, P., Lakhdar-Ghazal, N., \u0026amp; Benazzouz, A. (2014). Le parkinsonisme atypique induit par le manganèse est associé à une activité altérée des ganglions de la base et à des modifications des niveaux tissulaires de monoamines chez le rat. \u003ci\u003ePLoS ONE\u003c\/i\u003e, \u003ci\u003e9\u003c\/i\u003e(6), e98952. \u003ca href=\"http:\/\/doi.org\/10.1371\/journal.pone.0098952\"\u003ehttp:\/\/doi.org\/10.1371\/journal.pone.0098952\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eGal, R., Kaiser, M., Haspel, G., Libersat, F., Fouad, K., Libersat, F., … Yack, J. (2014). Arsenal sensoriel sur le dard de la guêpe bijou parasitoïde et son rôle possible dans l’identification des cerveaux de cafards. \u003ci\u003ePLoS ONE\u003c\/i\u003e, \u003ci\u003e9\u003c\/i\u003e(2), e89683. \u003ca href=\"http:\/\/doi.org\/10.1371\/journal.pone.0089683\"\u003ehttp:\/\/doi.org\/10.1371\/journal.pone.0089683\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eHuo, B.-X., Smith, J. B., \u0026amp; Drew, P. J. (2014). Couplage et découplage neurovasculaire dans le cortex pendant la locomotion volontaire. \u003ci\u003eThe Journal of Neuroscience : The Official Journal of the Society for Neuroscience\u003c\/i\u003e, \u003ci\u003e34\u003c\/i\u003e(33), 10975–81. \u003ca href=\"http:\/\/doi.org\/10.1523\/JNEUROSCI.1369-14.2014\"\u003ehttp:\/\/doi.org\/10.1523\/JNEUROSCI.1369-14.2014\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eHermann, P. M., Park, D., Beaulieu, E., \u0026amp; Wildering, W. C. (2013). Preuves d'un dysfonctionnement de la mémoire médié par l'inflammation chez les gastéropodes : des inhibiteurs putatifs de PLA2 et COX abolissent l'échec de la mémoire à long terme induit par des défis immunitaires systémiques. \u003ci\u003eBMC Neuroscience\u003c\/i\u003e, \u003ci\u003e14\u003c\/i\u003e(1), 83. \u003ca href=\"http:\/\/doi.org\/10.1186\/1471-2202-14-83\"\u003ehttp:\/\/doi.org\/10.1186\/1471-2202-14-83\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKam, T.-I., Song, S., Gwon, Y., Park, H., Yan, J.-J., Im, I., … Jung, Y.-K. (2013). FcγRIIb médie la neurotoxicité de l'amyloïde-β et les troubles de la mémoire dans la maladie d'Alzheimer. \u003ci\u003eThe Journal of Clinical Investigation\u003c\/i\u003e, \u003ci\u003e123\u003c\/i\u003e(7), 2791–802. \u003ca href=\"http:\/\/doi.org\/10.1172\/JCI66827\"\u003ehttp:\/\/doi.org\/10.1172\/JCI66827\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003ePark, H.-J., Bonmassar, G., Kaltenbach, J. A., Machado, A. G., Manzoor, N. F., \u0026amp; Gale, J. T. (2013). Activation du système nerveux central induite par une micro-stimulation magnétique. \u003ci\u003eNature Communications\u003c\/i\u003e, \u003ci\u003e4\u003c\/i\u003e, 2463. \u003ca href=\"http:\/\/doi.org\/10.1038\/ncomms3463\"\u003ehttp:\/\/doi.org\/10.1038\/ncomms3463\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eSanchez-Jimenez, A., Torets, C., \u0026amp; Panetsos, F. (2013). Traitement complémentaire de l'information haptique par des neurones à adaptation lente et rapide dans la voie trigéminothalamique. Électrophysiologie, modélisation mathématique et simulations des neurones liés aux vibrisses. \u003ci\u003eFrontiers in Cellular Neuroscience\u003c\/i\u003e, \u003ci\u003e7\u003c\/i\u003e, 79. \u003ca href=\"http:\/\/doi.org\/10.3389\/fncel.2013.00079\"\u003ehttp:\/\/doi.org\/10.3389\/fncel.2013.00079\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eSotoyama, H., Namba, H., Chiken, S., Nambu, A., \u0026amp; Nawa, H. (2013). L'exposition à la cytokine EGF conduit à une hyperactivité anormale des neurones GABA pallidaux : implications pour la schizophrénie et sa modélisation. \u003ci\u003eJournal of Neurochemistry\u003c\/i\u003e, \u003ci\u003e126\u003c\/i\u003e(4), 518–28. \u003ca href=\"http:\/\/doi.org\/10.1111\/jnc.12223\"\u003ehttp:\/\/doi.org\/10.1111\/jnc.12223\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eJirakulsomchok, D., Napawachirahat, S., Kunbootsri, N., Suttitum, T., Wannanon, P., Wyss, J. M., \u0026amp; Roysommuti, S. (2012). Réponse rénale altérée à l'infusion portale de solution saline hypertonique chez des rats traités à l'adriamycine. \u003ci\u003eClinical and Experimental Pharmacology and Physiology\u003c\/i\u003e, \u003ci\u003e39\u003c\/i\u003e(7), 636–641. \u003ca href=\"http:\/\/doi.org\/10.1111\/j.1440-1681.2012.05722.x\"\u003ehttp:\/\/doi.org\/10.1111\/j.1440-1681.2012.05722.x\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKato, Y. X., Furukawa, S., Samejima, K., Hironaka, N., \u0026amp; Kashino, M. (2012). Méthode basée sur le polyimide photosensible pour la fabrication de diverses architectures d'électrodes neuronales. \u003ci\u003eFrontiers in Neuroengineering\u003c\/i\u003e, \u003ci\u003e5\u003c\/i\u003e. \u003ca href=\"http:\/\/doi.org\/10.3389\/fneng.2012.00011\"\u003ehttp:\/\/doi.org\/10.3389\/fneng.2012.00011\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eOhnami, S., Kato, A., Ogawa, K., Shinohara, S., Ono, H., \u0026amp; Tanabe, M. (2012). Effets du milnacipran, un inhibiteur de la recapture de la 5-HT et de la noradrénaline, sur les potentiels de champ évoqués par les fibres C dans la potentialisation à long terme spinale et la douleur neuropathique. \u003ci\u003eBritish Journal of Pharmacology\u003c\/i\u003e, \u003ci\u003e167\u003c\/i\u003e(3), 537–47. \u003ca href=\"http:\/\/doi.org\/10.1111\/j.1476-5381.2012.02007.x\"\u003ehttp:\/\/doi.org\/10.1111\/j.1476-5381.2012.02007.x\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eRazy-Krajka, F., Brown, E. R., Horie, T., Callebert, J., Sasakura, Y., Joly, J.-S., … Vernier, P. (2012). Modulation monoaminergique de la photoréception chez l’ascidie : preuve d’un territoire proto-hypothalamo-rétinien. \u003ci\u003eBMC Biology\u003c\/i\u003e, \u003ci\u003e10\u003c\/i\u003e(1), 45. \u003ca href=\"http:\/\/doi.org\/10.1186\/1741-7007-10-45\"\u003ehttp:\/\/doi.org\/10.1186\/1741-7007-10-45\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eHu, W., Bi, Y., Zhang, K., Meng, F., \u0026amp; Zhang, J. (2011). La stimulation électrique à haute fréquence dans le noyau accumbens de rats traités à la morphine supprime la décharge neuronale dans les régions cérébrales liées à la récompense. \u003ci\u003eMedical Science Monitor : International Medical Journal of Experimental and Clinical Research\u003c\/i\u003e, \u003ci\u003e17\u003c\/i\u003e(6), BR153-60. Consulté sur \u003ca href=\"https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC3539543\" rel=\"noopener\" target=\"_blank\"\u003ehttps:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC3539543\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKim, J.-E., \u0026amp; Kang, T.-C. (2011). Le complexe récepteur P2X7–pannexine-1 diminue la susceptibilité aux crises médiée par les récepteurs muscariniques de l’acétylcholine chez la souris. \u003ci\u003eJournal of Clinical Investigation\u003c\/i\u003e, \u003ci\u003e121\u003c\/i\u003e(5), 2037–2047. \u003ca href=\"http:\/\/doi.org\/10.1172\/JCI44818\"\u003ehttp:\/\/doi.org\/10.1172\/JCI44818\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKim, J.-E., \u0026amp; Kang, T.-C. (2011). Le complexe récepteur P2X7-pannexine-1 diminue la susceptibilité aux crises médiée par les récepteurs muscariniques de l’acétylcholine chez la souris. \u003ci\u003eThe Journal of Clinical Investigation\u003c\/i\u003e, \u003ci\u003e121\u003c\/i\u003e(5), 2037–47. \u003ca href=\"http:\/\/doi.org\/10.1172\/JCI44818\"\u003ehttp:\/\/doi.org\/10.1172\/JCI44818\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eSchwarz, D., Bloom, D., Castro, R., Pagán, O. R., \u0026amp; Jiménez-Rivera, C. A. (2011). Le parthénolide bloque l’effet de la cocaïne sur l’activité de décharge spontanée des neurones dopaminergiques dans l’aire tegmentale ventrale. \u003ci\u003eCurrent Neuropharmacology\u003c\/i\u003e, \u003ci\u003e9\u003c\/i\u003e(1), 17–20. \u003ca href=\"http:\/\/doi.org\/10.2174\/157015911795017010\"\u003ehttp:\/\/doi.org\/10.2174\/157015911795017010\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eBedi, S. S., Yang, Q., Crook, R. J., Du, J., Wu, Z., Fishman, H. M., … Walters, E. T. (2010). L’activité spontanée chronique générée dans les somas des nocicepteurs primaires est associée à un comportement lié à la douleur après une lésion de la moelle épinière. \u003ci\u003eJournal of Neuroscience\u003c\/i\u003e, \u003ci\u003e30\u003c\/i\u003e(44), 14870–14882. \u003ca href=\"http:\/\/doi.org\/10.1523\/JNEUROSCI.2428-10.2010\"\u003ehttp:\/\/doi.org\/10.1523\/JNEUROSCI.2428-10.2010\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eGwak, Y. S., Unabia, G. C., \u0026amp; Hulsebosch, C. E. (2009). L'activation de p-38alpha MAPK contribue à l'hyperexcitabilité neuronale dans les régions caudales éloignées de la lésion de la moelle épinière. \u003ci\u003eExperimental Neurology\u003c\/i\u003e, \u003ci\u003e220\u003c\/i\u003e(1), 154–61. \u003ca href=\"http:\/\/doi.org\/10.1016\/j.expneurol.2009.08.012\"\u003ehttp:\/\/doi.org\/10.1016\/j.expneurol.2009.08.012\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eGwak, Y. S., Crown, E. D., Unabia, G. C., \u0026amp; Hulsebosch, C. E. (2008). La propentofylline atténue l'allodynie, l'activation gliale et module le tonus GABAergique après une lésion de la moelle épinière chez le rat. \u003ci\u003ePain\u003c\/i\u003e, \u003ci\u003e138\u003c\/i\u003e(2), 410–22. \u003ca href=\"http:\/\/doi.org\/10.1016\/j.pain.2008.01.021\"\u003ehttp:\/\/doi.org\/10.1016\/j.pain.2008.01.021\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eGreger, B., Kateb, B., Gruen, P., \u0026amp; Patterson, P. H. (2007). Dispositif hybride implantable en continu, canule-électrode, pour évaluer les effets des molécules sur les signaux électrophysiologiques chez des animaux en liberté. \u003ci\u003eJournal of Neuroscience Methods\u003c\/i\u003e, \u003ci\u003e163\u003c\/i\u003e(2), 321–325. \u003ca href=\"http:\/\/doi.org\/10.1016\/j.jneumeth.2007.03.017\"\u003ehttp:\/\/doi.org\/10.1016\/j.jneumeth.2007.03.017\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eZhao, P., Waxman, S. G., \u0026amp; Hains, B. C. (2006). Expression des canaux sodiques dans le noyau ventral postérolatéral du thalamus après une lésion nerveuse périphérique. \u003ci\u003eMolecular Pain\u003c\/i\u003e, \u003ci\u003e2\u003c\/i\u003e, 27. \u003ca href=\"http:\/\/doi.org\/10.1186\/1744-8069-2-27\"\u003ehttp:\/\/doi.org\/10.1186\/1744-8069-2-27\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eCharles, C. J., Jardine, D. L., Nicholls, M. G., \u0026amp; Richards, A. M. (2005). L'adrénomédulline augmente l'activité nerveuse sympathique cardiaque chez des moutons conscients normaux. \u003ci\u003eThe Journal of Endocrinology\u003c\/i\u003e, \u003ci\u003e187\u003c\/i\u003e(2), 275–81. \u003ca href=\"http:\/\/doi.org\/10.1677\/joe.1.06337\"\u003ehttp:\/\/doi.org\/10.1677\/joe.1.06337\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKaminski, R. M., Marini, H., Kim, W.-J., \u0026amp; Rogawski, M. A. (2005). Activité anticonvulsivante de l'androstérone et de l'étiocolanolone. \u003ci\u003eEpilepsia\u003c\/i\u003e, \u003ci\u003e46\u003c\/i\u003e(6), 819–827. \u003ca href=\"http:\/\/doi.org\/10.1111\/j.1528-1167.2005.00705.x\"\u003ehttp:\/\/doi.org\/10.1111\/j.1528-1167.2005.00705.x\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eLi, X., Conklin, D., Pan, H.-L., \u0026amp; Eisenach, J. C. (2003). La modulation allostérique des récepteurs à l'adénosine réduit l'hypersensibilité après inflammation périphérique par un mécanisme central. \u003ci\u003eThe Journal of Pharmacology and Experimental Therapeutics\u003c\/i\u003e, \u003ci\u003e305\u003c\/i\u003e(3), 950–5. \u003ca href=\"http:\/\/doi.org\/10.1124\/jpet.102.047951\"\u003ehttp:\/\/doi.org\/10.1124\/jpet.102.047951\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eMasino, S. A. (2003). Comparaison quantitative entre l'imagerie fonctionnelle et le spiking unitaire dans le cortex somatosensoriel du rat. \u003ci\u003eJournal of Neurophysiology\u003c\/i\u003e, \u003ci\u003e89\u003c\/i\u003e(3), 1702–12. \u003ca href=\"http:\/\/doi.org\/10.1152\/jn.00860.2002\"\u003ehttp:\/\/doi.org\/10.1152\/jn.00860.2002\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eWichmann, T., Kliem, M. A., \u0026amp; DeLong, M. R. (2001). Effets antiparkinsoniens et comportementaux de l'inactivation de la substantia nigra pars reticulata chez des primates hémiparkinsoniens. \u003ci\u003eExperimental Neurology\u003c\/i\u003e, \u003ci\u003e167\u003c\/i\u003e(2), 410–24. \u003ca href=\"http:\/\/doi.org\/10.1006\/exnr.2000.7572\"\u003ehttp:\/\/doi.org\/10.1006\/exnr.2000.7572\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42272907264090,"sku":"SYS-DAM80","price":3400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/dam80-angle_f93695dc-3aa8-43df-9023-a37909d3ab92.jpg?v=1766399620"}],"url":"https:\/\/wpiinc.com\/fr\/collections\/electrophysiology.oembed","provider":"World Precision Instruments","version":"1.0","type":"link"}