{"title":"Electrophysiology Essentials","description":"\u003ch1\u003eElectrophysiology Essentials\u003c\/h1\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAccurate electrophysiological measurements depend on reliable instrumentation and a stable recording environment. Explore essential electrophysiology equipment designed to support the measurement, monitoring, and analysis of electrical activity in biological tissues and cells. From impedance measurement instruments to specialized noise reduction and shielding solutions available through WPI Europe, these tools help researchers minimize electrical interference, improve signal quality, and obtain consistent, reproducible results. Whether conducting intracellular or extracellular recordings, studying neural activity, or investigating cellular electrical properties, the right equipment helps establish a dependable foundation for electrophysiology research.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"sys-omegaz-battery-operated-impedance-measurement","title":"Mesure d'impédance sur batterie","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaractéristiques\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFonctionne sur batterie\u003c\/li\u003e\n\u003cli\u003ePortable\u003c\/li\u003e\n\u003cli\u003eSonde à faible bruit incluse\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAvantages\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDéterminer la résistance de l'électrode capillaire en verre pendant le processus de biseautage de la micropipette.\u003c\/li\u003e\n\u003cli\u003eMesurer l'impédance des microélectrodes métalliques\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLes mesures d'impédance fournissent des informations précieuses sur l'interface électrode-électrolyte, notamment la résistance et la capacité du système.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAccessoires requis\u003c\/h2\u003e\n\u003cp\u003ePour mesurer la résistance sur une micropipette en verre préalablement tirée, vous aurez besoin d'un porte-microélectrode \u003ca href=\"\/fr\/ehbf-microelectrode-holder-straight-female-connector\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003eEHBF\u003c\/strong\u003e\u003c\/a\u003e. Pour tester l'impédance des microélectrodes métalliques, vous aurez besoin de l'adaptateur d'électrode numéro de pièce \u003ca href=\"\/fr\/5468-2mm-receptacle-to-0031-jack-for-omega-tipz\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003e5468\u003c\/strong\u003e\u003c\/a\u003e. Pour les deux applications, une électrode de référence est nécessaire, nous recommandons le numéro de pièce \u003ca href=\"\/fr\/var-3316-reference-cells\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003eRC1T\u003c\/strong\u003e\u003c\/a\u003e. Ces trois accessoires sont vendus séparément.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*Achetez \u003ca href=\"\/fr\/electrophysiology\/electrodes\/single-bipolar-concentric\"\u003edes microélectrodes métalliques\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eREMARQUE\u003c\/strong\u003e : Les microélectrodes métalliques préalablement calibrées à 1 kHz doivent être étalonnées avant utilisation avec \u003cstrong\u003eOmega-Tip-Z.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePour plus d'informations sur les microélectrodes, vous pouvez consulter les articles suivants :\u003c\/p\u003e\n\u003cdiv align=\"left\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003ca href=\"\/fr\/blog\/post\/metal-microelectrode-selection-guide\" target=\"_blank\" rel=\"noopener\"\u003eGuide de sélection des microélectrodes métalliques\u003c\/a\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/blog\/post\/metal-microelectrodes-basics\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003eNotions de base sur les microélectrodes métalliques\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/blog\/post\/metal-electrodes-selection-guide-for-assortments-and-concentric\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003eGuide de sélection pour les assortiments d'introduction et les électrodes concentriques\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/blog\/post\/metal-electrode-selection-guide-for-profile-a\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003eGuide de sélection pour le profil A\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/blog\/post\/metal-electrode-selection-guide-for-profile-b\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003eGuide de sélection pour le profil B\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/blog\/post\/metal-electrode-selection-guide-for-profile-c\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003eGuide de sélection pour le profil C\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/Omega-Tip-Z_IMs.pdf\"\u003eManuel d'instructions Omega-Tip-Z\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266243334234,"sku":"SYS-OMEGAZ","price":2603.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/omega-z_258f376c-b523-4d91-8d65-b21bfc6dee44.jpg?v=1766399629"}],"url":"https:\/\/wpiinc.com\/fr\/collections\/electrophysiology-essentials.oembed","provider":"World Precision Instruments","version":"1.0","type":"link"}