{"title":"Neurotransmitter Detection","description":"\u003ch1\u003e\u003cspan\u003eElectrochemical Detection of Oxidizable Compounds\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003eCarbon fiber microelectrodes have been used in both the detection of oxidizable compounds (Gonon, et al., 1978; Cahill and Wightman, 1995) and extracellular single-unit recording (Armstrong-James and Millar, 1979). WPI's ultra-sensitive and low-noise carbon fiber (CF) electrodes can be applied, with our Micro-C Potentiostat or similar instruments, in the electrochemical detection of catecholamines (epinephrine, norepinephrine and dopamine), indolamines (serotonin, 5-HT or melatonin), Fe (II) and other oxidizable compounds.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/cf10-cf30.jpg\" alt=\"\" width=\"449\" height=\"449\"\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDiameter: 10 um\u003c\/li\u003e\n\u003cli\u003eLength: 100 um\u003c\/li\u003e\n\u003cli\u003ePack of 5\u003c\/li\u003e\n\u003cli\u003eUltra-sensitive and low noise\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/microcconccurve.jpg\" alt=\"\" width=\"512\" height=\"396\"\u003e\u003c\/p\u003e\n\u003cp\u003eFig. 1-Excellent linearity in response of carbon fiber electrode (\u003cstrong\u003eCF30-500\u003c\/strong\u003e) to dopamine recorded on a \u003cstrong\u003eMicroC\u003c\/strong\u003e. Courtesy: Drs. D Yeomans and X.-T. Wang, University of Illinis at Chicago.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eCF electrodes (diameter of 10 or 30 um) respond with an excellent linearity to the oxidizable compounds and can detect the compounds as low as 0.2 nM. The shorter (25-100 um) CF electrodes are suitable for in vivo amperometric and voltammetric measurements. When used with the \u003ca href=\"https:\/\/www.wpiinc.com\/sys-microc-carbon-fiber-potentiostat\"\u003e\u003cstrong\u003eMicroC \u003c\/strong\u003e\u003c\/a\u003ePotentiostat, these CF electrodes can be activated and renewed in sensitivity for multiple use. The selective detection of catecholamines can be achieved with our Nafion-coated CF electrodes. For selective detection of 5-HT, please contact WPI for more information.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/microcfig2.jpg\" alt=\"\" width=\"476\" height=\"308\"\u003e\u003cbr\u003eFig. 2-Extracellular recording using a carbon electrode in CA1 region of the hippocampus in an anesthetized rat shows ultra-low noise ( ≤5μV). Courtesy: Dr. Carolyn Harley of Memorial University, Newfoundland, Canada.\u003c\/p\u003e","products":[{"product_id":"cf10-100-carbon-fiber-electrode-l-100-um","title":"Electrodo de Fibra de Carbono, L 100 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDiámetro: 10 um\u003c\/li\u003e\r\n\u003cli\u003eLongitud: 100 um\u003c\/li\u003e\r\n\u003cli\u003ePaquete de 5\u003c\/li\u003e\r\n\u003cli\u003eUltra sensible y bajo ruido\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_e3d4d5e4-04b7-4e0a-9a82-abcf269c1d97.jpg?v=1765945657\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eFig. 1-Excelente linealidad en la respuesta del electrodo de fibra de carbono (\u003ca href=\"\/es\/cf30-500-carbon-fiber-electrode-length-500-um\"\u003e\u003cstrong\u003eCF30-500\u003c\/strong\u003e\u003c\/a\u003e) a la dopamina registrada en un MicroC. Cortesía: Dres. D Yeomans y X.-T. Wang, Universidad de Illinois en Chicago.\u003c\/p\u003e\r\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\r\n\u003cp\u003eLos electrodos de CF (diámetro de 10 o 30 um) responden con una excelente linealidad a los compuestos oxidable y pueden detectar compuestos tan bajos como 0.2 nM. Los electrodos de CF más cortos (25-100 um) son adecuados para mediciones amperométricas y voltamétricas in vivo. Cuando se usan con el Potenciostato MicroC, estos electrodos de CF pueden activarse y renovar su sensibilidad para múltiples usos. La detección selectiva de catecolaminas se puede lograr con nuestros electrodos de CF recubiertos con Nafion. Para la detección selectiva de 5-HT, por favor contacte a WPI para más información.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_08d43912-7321-4d82-a55c-4e79740271ea.jpg?v=1765945662\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Registro extracelular usando un electrodo de carbono en la región CA1 del hipocampo en una rata anestesiada muestra un ruido ultra bajo ( ≤5μV). Cortesía: Dra. Carolyn Harley de la Universidad Memorial, Terranova, Canadá.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eManual de instrucciones de microelectrodos de fibra de carbono CF10\/CF30\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eM. Potie, F. Bedioui, J. Devnck\u003c\/strong\u003e \"Nuevas microfibras compuestas modificadas de carbono para la determinación sensible y selectiva de concentraciones fisiológicamente relevantes de óxido nítrico en solución\" \u003cspan style=\"font-style: italic;\"\u003eElectroanálisis\u003c\/span\u003e 11. 1999: 845-850\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266095517786,"sku":"CF10-100","price":617.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_13_6dc25553-9da7-453c-bd19-4e375c1c32b5.jpg?v=1766396964"},{"product_id":"cf10-250-carbon-fiber-electrode-l-250-um","title":"Electrodo de Fibra de Carbono, L 250 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDiámetro: 10 um\u003c\/li\u003e\r\n\u003cli\u003eLongitud: 250 um\u003c\/li\u003e\r\n\u003cli\u003ePaquete de 5\u003c\/li\u003e\r\n\u003cli\u003eUltra sensible y bajo ruido\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_a62d9011-5ee7-4d22-ac3d-cd8f685aad28.jpg?v=1765945674\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eFig. 1-Excelente linealidad en la respuesta del electrodo de fibra de carbono (CF30-500) a la dopamina registrada en un MicroC. Cortesía: Dres. D Yeomans y X.-T. Wang, Universidad de Illinois en Chicago.\u003c\/p\u003e\r\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\r\n\u003cp\u003eLos electrodos CF (diámetro de 10 o 30 um) responden con una excelente linealidad a los compuestos oxidables y pueden detectar compuestos en concentraciones tan bajas como 0.2 nM. Los electrodos CF más cortos (25-100 um) son adecuados para mediciones amperométricas y voltamétricas in vivo. Cuando se usan con el Potenciostato MicroC, estos electrodos CF pueden activarse y renovar su sensibilidad para múltiples usos. La detección selectiva de catecolaminas se puede lograr con nuestros electrodos CF recubiertos con Nafion. Para la detección selectiva de 5-HT, por favor contacte a WPI para más información.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_03016fe5-f950-405f-9e35-96e577b46c44.jpg?v=1765945680\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Registro extracelular usando un electrodo de carbono en la región CA1 del hipocampo en una rata anestesiada muestra ruido ultra bajo ( ≤5μV). Cortesía: Dra. Carolyn Harley de la Universidad Memorial, Newfoundland, Canadá.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eManual de instrucciones de microelectrodos de fibra de carbono CF10\/CF30\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eM. Potie, F. Bedioui, J. Devnck\u003c\/strong\u003e \"Nuevas microfibras compuestas modificadas de carbono para la determinación sensible y selectiva de concentraciones fisiológicamente relevantes de óxido nítrico en solución\" \u003cspan style=\"font-style: italic;\"\u003eElectroanálisis\u003c\/span\u003e 11. 1999: 845-850\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266096369754,"sku":"CF10-250","price":617.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_3_03b153a2-dca5-4fa6-bf3d-813a73264d68.jpg?v=1766396975"},{"product_id":"cf10-500-carbon-fiber-electrode-l-500-um","title":"Electrodo de Fibra de Carbono, L 500 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDiámetro: 10 um\u003c\/li\u003e\r\n\u003cli\u003eLongitud: 500 um\u003c\/li\u003e\r\n\u003cli\u003ePaquete de 5\u003c\/li\u003e\r\n\u003cli\u003eUltra sensible y bajo ruido\u003c\/li\u003e\r\n\u003cli\u003eFabricado por encargo. Por favor permita hasta cuatro semanas para el tiempo de fabricación.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_7fa4e40e-da05-4595-b4c9-a60899b7eb38.jpg?v=1765945689\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eFig. 1-Excelente linealidad en la respuesta del electrodo de fibra de carbono (CF30-500) a la dopamina registrada en un MicroC. Cortesía: Dres. D Yeomans y X.-T. Wang, Universidad de Illinois en Chicago.\u003c\/p\u003e\r\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\r\n\u003cp\u003eLos electrodos CF (diámetro de 10 o 30 um) responden con una excelente linealidad a los compuestos oxidables y pueden detectar compuestos en concentraciones tan bajas como 0.2 nM. Los electrodos CF más cortos (25-100 um) son adecuados para mediciones amperométricas y voltamétricas in vivo. Cuando se usan con el Potenciostato MicroC, estos electrodos CF pueden activarse y renovar su sensibilidad para múltiples usos. La detección selectiva de catecolaminas se puede lograr con nuestros electrodos CF recubiertos con Nafion. Para la detección selectiva de 5-HT, por favor contacte a WPI para más información.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_d3b273d0-5cf0-4289-82ba-bf02e9b29850.jpg?v=1765945695\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Registro extracelular usando un electrodo de carbono en la región CA1 del hipocampo en una rata anestesiada muestra ruido ultra bajo ( ≤5μV). Cortesía: Dra. Carolyn Harley de la Universidad Memorial, Newfoundland, Canadá.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eManual de instrucciones de microelectrodos de fibra de carbono CF10\/CF30\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eM. Potie, F. Bedioui, J. Devnck\u003c\/strong\u003e \"Nuevas microfibras compuestas modificadas de carbono para la determinación sensible y selectiva de concentraciones fisiológicamente relevantes de óxido nítrico en solución\" \u003cspan style=\"font-style: italic;\"\u003eElectroanálisis\u003c\/span\u003e 11. 1999: 845-850\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266097483866,"sku":"CF10-500","price":780.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_109e2aec-57ce-4b50-bd48-34b1a8060cd0.jpg?v=1766396983"},{"product_id":"cf30-100-carbon-fiber-electrode-length-100-um","title":"Electrodo de Fibra de Carbono, Longitud 100 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDiámetro: 30 um\u003c\/li\u003e\r\n\u003cli\u003eLongitud: 100 um\u003c\/li\u003e\r\n\u003cli\u003ePaquete de 5\u003c\/li\u003e\r\n\u003cli\u003eUltra sensible y bajo ruido\u003c\/li\u003e\r\n\u003cli\u003eFabricado por encargo. Por favor permita hasta cuatro semanas para el tiempo de fabricación.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_7222799f-5226-4f27-b10d-aadd2e6bcb15.jpg?v=1765945705\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eFig. 1-Excelente linealidad en la respuesta del electrodo de fibra de carbono (CF30-500) a dopamina registrado en un MicroC. Cortesía: Dres. D Yeomans y X.-T. Wang, Universidad de Illinois en Chicago.\u003c\/p\u003e\r\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\r\n\u003cp\u003eLos electrodos CF (diámetro de 10 o 30 um) responden con una excelente linealidad a los compuestos oxidable y pueden detectar compuestos tan bajos como 0.2 nM. Los electrodos CF más cortos (25-100 um) son adecuados para mediciones amperométricas y voltamétricas in vivo. Cuando se usan con el Potenciostato Micro-C, estos electrodos CF pueden activarse y renovar su sensibilidad para múltiples usos. La detección selectiva de catecolaminas se puede lograr con nuestros electrodos CF recubiertos con Nafion. Para la detección selectiva de 5-HT, por favor contacte a WPI para más información.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_bd13e8e1-b97a-4af5-85df-8488e1f47880.jpg?v=1765945710\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Registro extracelular usando un electrodo de carbono en la región CA1 del hipocampo en una rata anestesiada muestra ruido ultra bajo ( ≤5μV). Cortesía: Dra. Carolyn Harley de la Universidad Memorial, Newfoundland, Canadá.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eManual de instrucciones de microelectrodos de fibra de carbono CF10\/CF30\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eM. Potie, F. Bedioui, J. Devnck\u003c\/strong\u003e \"Nuevas microfibras compuestas modificadas de carbono para la determinación sensible y selectiva de concentraciones fisiológicamente relevantes de óxido nítrico en solución\" \u003cspan style=\"font-style: italic;\"\u003eElectroanálisis\u003c\/span\u003e 11. 1999: 845-850\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266098499674,"sku":"CF30-100","price":598.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_1_c934e29a-3f49-44c9-9c98-48c75a973015.jpg?v=1766396991"},{"product_id":"cf30-1000-carbon-fiber-electrode-length-1000-um","title":"Electrodo de Fibra de Carbono, Longitud 1000 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDiámetro: 30 um\u003c\/li\u003e\r\n\u003cli\u003eLongitud: 1000 um\u003c\/li\u003e\r\n\u003cli\u003ePaquete de 5\u003c\/li\u003e\r\n\u003cli\u003eUltra sensible y bajo ruido\u003c\/li\u003e\r\n\u003cli\u003eFabricado por encargo. Por favor permita hasta cuatro semanas para el tiempo de fabricación.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_96d2d802-7130-4baf-b6f1-5f6c98d4868a.jpg?v=1765945720\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eFig. 1-Excelente linealidad en la respuesta del electrodo de fibra de carbono (CF30-500) a dopamina registrada en un MicroC. Cortesía: Dres. D Yeomans y X.-T. Wang, Universidad de Illinois en Chicago.\u003c\/p\u003e\r\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\r\n\u003cp\u003eLos electrodos CF (diámetro de 10 o 30 um) responden con una excelente linealidad a los compuestos oxidable y pueden detectar compuestos en concentraciones tan bajas como 0.2 nM. Los electrodos CF más cortos (25-100 um) son adecuados para mediciones amperométricas y voltamétricas in vivo. Cuando se usan con el Potenciostato Micro-C, estos electrodos CF pueden activarse y renovar su sensibilidad para múltiples usos. La detección selectiva de catecolaminas se puede lograr con nuestros electrodos CF recubiertos con Nafion. Para la detección selectiva de 5-HT, por favor contacte a WPI para más información.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_6ce96aca-d329-41da-9795-88e26b78eccc.jpg?v=1765945726\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Registro extracelular usando un electrodo de carbono en la región CA1 del hipocampo en una rata anestesiada muestra un ruido ultra bajo (≤5μV). Cortesía: Dra. Carolyn Harley de la Universidad Memorial, Newfoundland, Canadá.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eManual de instrucciones de microelectrodos de fibra de carbono CF10\/CF30\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eM. Potie, F. Bedioui, J. Devnck\u003c\/strong\u003e \"Nuevas microfibras compuestas modificadas de carbono para la determinación sensible y selectiva de concentraciones fisiológicamente relevantes de óxido nítrico en solución\" \u003cspan style=\"font-style: italic;\"\u003eElectroanálisis\u003c\/span\u003e 11. 1999: 845-850\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266099155034,"sku":"CF30-1000","price":638.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_2_80999054-e9c4-4f7e-be7c-c4aa15144496.jpg?v=1766396999"},{"product_id":"cf30-50-carbon-fiber-electrode-length-50-um","title":"Electrodo de Fibra de Carbono, Longitud 50 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDiámetro: 30 um\u003c\/li\u003e\r\n\u003cli\u003eLongitud: 50 um\u003c\/li\u003e\r\n\u003cli\u003ePaquete de 5\u003c\/li\u003e\r\n\u003cli\u003eUltra sensible y bajo ruido\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_f4197b9a-8055-4903-8e3a-b0a74aa8513d.jpg?v=1765945738\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eFig. 1-Excelente linealidad en la respuesta del electrodo de fibra de carbono (CF30-500) a la dopamina registrada en un MicroC. Cortesía: Dres. D Yeomans y X.-T. Wang, Universidad de Illinois en Chicago.\u003c\/p\u003e\r\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\r\n\u003cp\u003eLos electrodos CF (diámetro de 10 o 30 um) responden con una excelente linealidad a los compuestos oxidables y pueden detectar compuestos en concentraciones tan bajas como 0.2 nM. Los electrodos CF más cortos (25-100 um) son adecuados para mediciones amperométricas y voltamétricas in vivo. Cuando se usan con el Micro-C Potenciostato, estos electrodos CF pueden activarse y renovar su sensibilidad para múltiples usos. La detección selectiva de catecolaminas se puede lograr con nuestros electrodos CF recubiertos de Nafion. Para la detección selectiva de 5-HT, por favor contacte a WPI para más información.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_11f44941-36cb-40c3-b1d9-0abef6fd5ac9.jpg?v=1765945744\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Registro extracelular usando un electrodo de carbono en la región CA1 del hipocampo en una rata anestesiada muestra ruido ultra bajo ( ≤5μV). Cortesía: Dra. Carolyn Harley de la Universidad Memorial, Newfoundland, Canadá.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eManual de instrucciones de microelectrodos de fibra de carbono CF10\/CF30\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eM. Potie, F. Bedioui, J. Devnck\u003c\/strong\u003e \"Nuevas microfibras compuestas modificadas de carbono para la determinación sensible y selectiva de concentraciones fisiológicamente relevantes de óxido nítrico en solución\" \u003cspan style=\"font-style: italic;\"\u003eElectroanálisis\u003c\/span\u003e 11. 1999: 845-850\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266100269146,"sku":"CF30-50","price":587.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_7_479d5ce6-8774-471c-85e4-f414a9ea01fb.jpg?v=1766397010"},{"product_id":"cf30-500-carbon-fiber-electrode-length-500-um","title":"Electrodo de Fibra de Carbono, Longitud 500 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDiámetro: 30 um\u003c\/li\u003e\r\n\u003cli\u003eLongitud: 500 um\u003c\/li\u003e\r\n\u003cli\u003ePaquete de 5\u003c\/li\u003e\r\n\u003cli\u003eUltra sensible y bajo ruido\u003c\/li\u003e\r\n\u003cli\u003eFabricado por encargo. Por favor permita hasta cuatro semanas para el tiempo de fabricación.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_2606cfc9-9a97-4771-a2ff-557464cfd0cd.jpg?v=1765945753\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eFig. 1-Excelente linealidad en la respuesta del electrodo de fibra de carbono (CF30-500) a la dopamina registrada en un MicroC. Cortesía: Dres. D Yeomans y X.-T. Wang, Universidad de Illinois en Chicago.\u003c\/p\u003e\r\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\r\n\u003cp\u003eLos electrodos CF (diámetro de 10 o 30 um) responden con una excelente linealidad a los compuestos oxidable y pueden detectar compuestos en concentraciones tan bajas como 0.2 nM. Los electrodos CF más cortos (25-100 um) son adecuados para mediciones amperométricas y voltamétricas in vivo. Cuando se usan con el Potenciostato Micro-C, estos electrodos CF pueden activarse y renovar su sensibilidad para múltiples usos. La detección selectiva de catecolaminas se puede lograr con nuestros electrodos CF recubiertos con Nafion. Para la detección selectiva de 5-HT, por favor contacte a WPI para más información.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_1f081c2f-c571-4d63-a4e7-9a148d3b596a.jpg?v=1765945759\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Registro extracelular usando un electrodo de carbono en la región CA1 del hipocampo en una rata anestesiada muestra un ruido ultra bajo ( ≤5μV). Cortesía: Dra. Carolyn Harley de la Universidad Memorial, Newfoundland, Canadá.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eManual de instrucciones de microelectrodos de fibra de carbono CF10\/CF30\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eM. Potie, F. Bedioui, J. Devnck\u003c\/strong\u003e \"Nuevas microfibras compuestas modificadas de carbono para la determinación sensible y selectiva de concentraciones fisiológicamente relevantes de óxido nítrico en solución\" \u003cspan style=\"font-style: italic;\"\u003eElectroanálisis\u003c\/span\u003e 11. 1999: 845-850\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266101186650,"sku":"CF30-500","price":975.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_12_8618a2d2-20a1-4070-a422-0a61852f0fb1.jpg?v=1766397018"},{"product_id":"cfn10-100-carbon-fiber-electrode-dia-10-um-length-100-um","title":"Electrodo de Fibra de Carbono, Diámetro 10 um, Longitud 100 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDiámetro: 10 um\u003c\/li\u003e\r\n\u003cli\u003eLongitud: 100 um\u003c\/li\u003e\r\n\u003cli\u003ePaquete de 5\u003c\/li\u003e\r\n\u003cli\u003eUltra sensible y bajo ruido\u003c\/li\u003e\r\n\u003cli\u003eRecubierto con Nafion\u003c\/li\u003e\r\n\u003cli\u003eFabricado por encargo. Por favor permita hasta cuatro semanas para la fabricación.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_bf1615fd-6116-46a7-a977-6d02a787220a.jpg?v=1765945768\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eFig. 1-Excelente linealidad en la respuesta del electrodo de fibra de carbono (CF30-500) a la dopamina registrada en un MicroC. Cortesía: Dres. D Yeomans y X.-T. Wang, Universidad de Illinois en Chicago.\u003c\/p\u003e\r\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\r\n\u003cp\u003eLos electrodos CF (diámetro de 10 o 30 um) responden con una excelente linealidad a los compuestos oxidable y pueden detectar compuestos tan bajos como 0.2 nM. Los electrodos CF más cortos (25-100 um) son adecuados para mediciones amperométricas y voltamétricas \u003cem\u003ein vivo\u003c\/em\u003e. Cuando se usan con el Potenciostato MicroC, estos electrodos CF pueden activarse y renovar su sensibilidad para múltiples usos. La detección selectiva de catecolaminas se puede lograr con nuestros electrodos CF recubiertos con Nafion. Para la detección selectiva de 5-HT, por favor contacte a WPI para más información.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_3925ceaa-8c2d-4ed3-acd2-e1c45613628f.jpg?v=1765945774\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Registro extracelular usando un electrodo de carbono en la región CA1 del hipocampo en una rata anestesiada muestra ruido ultra bajo ( ≤5μV). Cortesía: Dra. Carolyn Harley de la Universidad Memorial, Newfoundland, Canadá.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eManual de instrucciones de microelectrodos de fibra de carbono CF10\/CF30\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eL. Yavich, P. Jkl, H.Tanila\u003c\/strong\u003e \"Desbordamiento de noradrenalina en el giro dentado de ratón tras la estimulación del locus coeruleus y natural: monitoreo en tiempo real mediante voltametría in vivo\" \u003cspan style=\"font-style: italic;\"\u003eJ of Neurochemistry\u003c\/span\u003e 95. 2005: 641-650\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266101874778,"sku":"CFN10-100","price":748.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_6_11380561-fad5-40c0-af6e-cac2cff52198.jpg?v=1766397026"},{"product_id":"cfn10-250-carbon-fiber-electrode-dia-10-umlength-250-um","title":"Electrodo de Fibra de Carbono, Diámetro 10 um, Longitud 250 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDiámetro: 10 um\u003c\/li\u003e\r\n\u003cli\u003eLongitud: 250 um\u003c\/li\u003e\r\n\u003cli\u003ePaquete de 5\u003c\/li\u003e\r\n\u003cli\u003eUltra sensible y bajo ruido\u003c\/li\u003e\r\n\u003cli\u003eRecubierto con Nafion\u003c\/li\u003e\r\n\u003cli\u003eFabricado por encargo. Por favor permita hasta cuatro semanas para el tiempo de fabricación.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_bd96a5a8-5ce8-4a2b-a6d5-fa02f36ea82f.jpg?v=1765945784\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eFig. 1-Excelente linealidad en la respuesta del electrodo de fibra de carbono (CF30-500) a dopamina registrado en un MicroC. Cortesía: Dres. D Yeomans y X.-T. Wang, Universidad de Illinois en Chicago.\u003c\/p\u003e\r\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\r\n\u003cp\u003eLos electrodos CF (diámetro de 10 o 30 um) responden con una excelente linealidad a los compuestos oxidable y pueden detectar compuestos tan bajos como 0.2 nM. Los electrodos CF más cortos (25-100 um) son adecuados para mediciones amperométricas y voltamétricas in vivo. Cuando se usan con el Potenciostato MicroC, estos electrodos CF pueden activarse y renovar su sensibilidad para múltiples usos. La detección selectiva de catecolaminas se puede lograr con nuestros electrodos CF recubiertos con Nafion. Para la detección selectiva de 5-HT, por favor contacte a WPI para más información.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_e5dcc476-258f-4c0a-b6a7-83acfa4117d7.jpg?v=1765945789\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Registro extracelular usando un electrodo de carbono en la región CA1 del hipocampo en una rata anestesiada muestra ruido ultra bajo ( ≤5μV). Cortesía: Dra. Carolyn Harley de la Universidad Memorial, Newfoundland, Canadá.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eManual de instrucciones de microelectrodos de fibra de carbono CF10\/CF30\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eL. Yavich, P. Jkl, H.Tanila\u003c\/strong\u003e \"Desbordamiento de noradrenalina en el giro dentado de ratón tras la estimulación del locus coeruleus y natural: monitoreo en tiempo real mediante voltametría in vivo\" \u003cspan style=\"font-style: italic;\"\u003eJ of Neurochemistry\u003c\/span\u003e 95. 2005: 641-650\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266102300762,"sku":"CFN10-250","price":651.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_10_7cae82b9-3dd0-48d3-b487-5c942380292c.jpg?v=1766397034"},{"product_id":"cfn10-50-carbon-fiber-electrode-dia-10-um-length-50-um","title":"Electrodo de Fibra de Carbono, Diámetro 10 um, Longitud 50 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDiámetro: 10 um\u003c\/li\u003e\r\n\u003cli\u003eLongitud: 50 um\u003c\/li\u003e\r\n\u003cli\u003ePaquete de 5\u003c\/li\u003e\r\n\u003cli\u003eUltra sensible y bajo ruido\u003c\/li\u003e\r\n\u003cli\u003eRecubierto con Nafion\u003c\/li\u003e\r\n\u003cli\u003eFabricado por encargo. Por favor permita hasta cuatro semanas para el tiempo de fabricación.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_038340f4-8365-4143-8152-caf723d75371.jpg?v=1765945802\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eFig. 1-Excelente linealidad en la respuesta del electrodo de fibra de carbono (CF30-500) a la dopamina registrada en un MicroC. Cortesía: Dres. D Yeomans y X.-T. Wang, Universidad de Illinois en Chicago.\u003c\/p\u003e\r\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\r\n\u003cp\u003eLos electrodos CF (diámetro de 10 o 30 um) responden con una excelente linealidad a los compuestos oxidable y pueden detectar compuestos en concentraciones tan bajas como 0.2 nM. Los electrodos CF más cortos (25-100 um) son adecuados para mediciones amperométricas y voltamétricas in vivo. Cuando se usan con el Potenciostato MicroC, estos electrodos CF pueden activarse y renovar su sensibilidad para múltiples usos. La detección selectiva de catecolaminas se puede lograr con nuestros electrodos CF recubiertos con Nafion. Para la detección selectiva de 5-HT, por favor contacte a WPI para más información.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_c526317b-4231-46bd-9d2a-01db8d76437c.jpg?v=1765945808\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Registro extracelular usando un electrodo de carbono en la región CA1 del hipocampo en una rata anestesiada muestra un ruido ultra bajo (≤5μV). Cortesía: Dra. Carolyn Harley de la Universidad Memorial, Newfoundland, Canadá.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eManual de instrucciones de microelectrodos de fibra de carbono CF10\/CF30\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eL. Yavich, P. Jkl, H.Tanila\u003c\/strong\u003e \"Desbordamiento de noradrenalina en el giro dentado de ratón tras la estimulación del locus coeruleus y natural: monitoreo en tiempo real mediante voltametría in vivo\" \u003cspan style=\"font-style: italic;\"\u003eJ of Neurochemistry\u003c\/span\u003e 95. 2005: 641-650\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266102530138,"sku":"CFN10-50","price":840.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_5_46877531-dffa-4171-9f12-1e053236a2aa.jpg?v=1766397045"},{"product_id":"cfn30-100-carbon-fiber-electrode-dia-30-um-l-100-um","title":"Electrodo de Fibra de Carbono, Diámetro 30 um, L 100 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDiámetro: 30 um\u003c\/li\u003e\n\u003cli\u003eLongitud: 100 um\u003c\/li\u003e\n\u003cli\u003ePaquete de 5\u003c\/li\u003e\n\u003cli\u003eUltrasensible y bajo ruido\u003c\/li\u003e\n\u003cli\u003eRecubierto con Nafion\u003c\/li\u003e\n\u003cli\u003eFabricado por encargo. Por favor, permita hasta cuatro semanas para el tiempo de fabricación.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\n\u003cp\u003eLos electrodos de CF (diámetro de 10 o 30 um) responden con una excelente linealidad a los compuestos oxidables y pueden detectar compuestos en concentraciones tan bajas como 0.2 nM. Los electrodos de CF más cortos (25-100 um) son adecuados para mediciones amperométricas y voltamétricas in vivo. Cuando se usan con el Potenciostato Micro-C, estos electrodos de CF pueden activarse y renovar su sensibilidad para múltiples usos. La detección selectiva de catecolaminas se puede lograr con nuestros electrodos de CF recubiertos con Nafion. Para la detección selectiva de 5-HT, por favor contacte a WPI para más información.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eL. Yavich, P. JkI, H.Tanila\u003c\/strong\u003e \"Desbordamiento de noradrenalina en el giro dentado de ratón tras la estimulación del locus coeruleus y natural: monitoreo en tiempo real mediante voltametría in vivo\" \u003cspan style=\"font-style: italic;\"\u003eJ of Neurochemistry\u003c\/span\u003e 95. 2005: 641-650\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266103119962,"sku":"CFN30-100","price":617.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_9_3d629af9-4e18-4ae9-866b-d47e41bfbfd5.jpg?v=1766397053"},{"product_id":"cfn30-1000-carbon-fiber-electrode-dia-30-um-l-1000-um","title":"Electrodo de Fibra de Carbono, Diámetro 30 um, L 1000 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDiámetro: 30 um\u003c\/li\u003e\r\n\u003cli\u003eLongitud: 1000 um\u003c\/li\u003e\r\n\u003cli\u003ePaquete de 5\u003c\/li\u003e\r\n\u003cli\u003eUltra sensible y bajo ruido\u003c\/li\u003e\r\n\u003cli\u003eRecubierto con Nafion\u003c\/li\u003e\r\n\u003cli\u003eFabricado por encargo. Por favor permita hasta cuatro semanas para la fabricación.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_0c25b942-91cb-402f-9a50-2a8b99e7848a.jpg?v=1765945821\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eFig. 1-Excelente linealidad en la respuesta del electrodo de fibra de carbono (CF30-500) a la dopamina registrada en un MicroC. Cortesía: Dres. D Yeomans y X.-T. Wang, Universidad de Illinois en Chicago.\u003c\/p\u003e\r\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\r\n\u003cp\u003eLos electrodos CF (diámetro de 10 o 30 um) responden con una excelente linealidad a los compuestos oxidable y pueden detectar compuestos en concentraciones tan bajas como 0.2 nM. Los electrodos CF más cortos (25-100 um) son adecuados para mediciones amperométricas y voltamétricas in vivo. Cuando se usan con el Potenciostato Micro-C, estos electrodos CF pueden activarse y renovar su sensibilidad para múltiples usos. La detección selectiva de catecolaminas se puede lograr con nuestros electrodos CF recubiertos con Nafion. Para la detección selectiva de 5-HT, por favor contacte a WPI para más información.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_6e67a66f-81b2-422e-a695-32c306456a3b.jpg?v=1765945827\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Registro extracelular usando un electrodo de carbono en la región CA1 del hipocampo en una rata anestesiada muestra ruido ultra bajo (≤5μV). Cortesía: Dra. Carolyn Harley de la Universidad Memorial, Newfoundland, Canadá.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eManual de instrucciones de microelectrodos de fibra de carbono CF10\/CF30\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eL. Yavich, P. Jkl, H.Tanila\u003c\/strong\u003e \"Desbordamiento de noradrenalina en el giro dentado de ratón tras la estimulación del locus coeruleus y natural: monitoreo en tiempo real mediante voltametría in vivo\" \u003cspan style=\"font-style: italic;\"\u003eJ of Neurochemistry\u003c\/span\u003e 95. 2005: 641-650\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266103382106,"sku":"CFN30-1000","price":617.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_4_daa8afce-7804-485b-a927-db1bb35c794d.jpg?v=1766397062"},{"product_id":"cfn30-250-carbon-fiber-electrode-dia-30-um-l-250-um","title":"Electrodo de Fibra de Carbono, Diámetro 30 um, L 250 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDiámetro: 30 um\u003c\/li\u003e\n\u003cli\u003eLongitud: 250 um\u003c\/li\u003e\n\u003cli\u003ePaquete de 5\u003c\/li\u003e\n\u003cli\u003eUltra sensible y bajo ruido\u003c\/li\u003e\n\u003cli\u003eRecubierto con Nafion\u003c\/li\u003e\n\u003cli\u003eFabricado por encargo. Por favor permita hasta cuatro semanas para el tiempo de fabricación.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_cda34e48-3c5c-46f2-a0c7-b2aa8528eb36.jpg?v=1765945836\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\n\u003cp\u003eFig. 1-Excelente linealidad en la respuesta del electrodo de fibra de carbono (CF30-500) a la dopamina registrada en un MicroC. Cortesía: Dres. D Yeomans y X.-T. Wang, Universidad de Illinois en Chicago.\u003c\/p\u003e\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\n\u003cp\u003eLos electrodos CF (diámetro de 10 o 30 um) responden con una excelente linealidad a los compuestos oxidable y pueden detectar compuestos en concentraciones tan bajas como 0.2 nM. Los electrodos CF más cortos (25-100 um) son adecuados para mediciones amperométricas y voltamétricas in vivo. Cuando se usan con el Micro-C Potentiostat, estos electrodos CF pueden activarse y renovar su sensibilidad para múltiples usos. La detección selectiva de catecolaminas se puede lograr con nuestros electrodos CF recubiertos de Nafion. Para la detección selectiva de 5-HT, por favor contacte a WPI para más información.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_a014042c-2133-4ae0-bcee-e87261c43e92.jpg?v=1765945842\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Registro extracelular usando un electrodo de carbono en la región CA1 del hipocampo en una rata anestesiada muestra ruido ultra bajo (≤5μV). Cortesía: Dra. Carolyn Harley de la Universidad Memorial, Newfoundland, Canadá.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eManual de instrucciones de microelectrodos de fibra de carbono CF10\/CF30\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eL. Yavich, P. Jkl, H.Tanila\u003c\/strong\u003e \"Desbordamiento de noradrenalina en el giro dentado de ratón tras la estimulación del locus coeruleus y natural: monitoreo en tiempo real mediante voltametría in vivo\" \u003cspan style=\"font-style: italic;\"\u003eJ of Neurochemistry\u003c\/span\u003e 95. 2005: 641-650\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266105282650,"sku":"CFN30-250","price":617.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_11_1000985c-878d-4e91-9ee2-4e8b65ca9369.jpg?v=1766397069"},{"product_id":"cfn30-50-carbon-fiber-electrode-dia-30-um-l-50-um","title":"Electrodo de Fibra de Carbono, Diámetro 30 um, L 50 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDiámetro: 30 um\u003c\/li\u003e\n\u003cli\u003eLongitud: 50 um\u003c\/li\u003e\n\u003cli\u003ePaquete de 5\u003c\/li\u003e\n\u003cli\u003eUltra sensible y bajo ruido\u003c\/li\u003e\n\u003cli\u003eRecubierto con Nafion\u003c\/li\u003e\n\u003cli\u003eFabricado por encargo. Por favor permita hasta cuatro semanas para el tiempo de fabricación.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_a4a365ca-0c0b-43d1-aa07-62026b957e1a.jpg?v=1765945854\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\n\u003cp\u003eFig. 1-Excelente linealidad en la respuesta del electrodo de fibra de carbono (CF30-500) a la dopamina registrada en un MicroC. Cortesía: Dres. D Yeomans y X.-T. Wang, Universidad de Illinois en Chicago.\u003c\/p\u003e\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\n\u003cp\u003eLos electrodos CF (diámetro de 10 o 30 um) responden con una excelente linealidad a los compuestos oxidable y pueden detectar compuestos en concentraciones tan bajas como 0.2 nM. Los electrodos CF más cortos (25-100 um) son adecuados para mediciones amperométricas y voltamétricas in vivo. Cuando se usan con el Micro-C Potenciostato, estos electrodos CF pueden activarse y renovar su sensibilidad para múltiples usos. La detección selectiva de catecolaminas se puede lograr con nuestros electrodos CF recubiertos con Nafion. Para la detección selectiva de 5-HT, por favor contacte a WPI para más información.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_a6b6f373-ebd0-4c58-ac83-2e305bd7285b.jpg?v=1765945859\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Registro extracelular usando un electrodo de carbono en la región CA1 del hipocampo en una rata anestesiada muestra ruido ultra bajo (≤5μV). Cortesía: Dra. Carolyn Harley de la Universidad Memorial, Newfoundland, Canadá.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eManual de instrucciones de microelectrodos de fibra de carbono CF10\/CF30\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eL. Yavich, P. Jkl, H.Tanila\u003c\/strong\u003e \"Desbordamiento de noradrenalina en el giro dentado de ratón tras la estimulación del locus coeruleus y natural: monitoreo en tiempo real mediante voltametría in vivo\" \u003cspan style=\"font-style: italic;\"\u003eJ of Neurochemistry\u003c\/span\u003e 95. 2005: 641-650\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266106265690,"sku":"CFN30-50","price":617.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_8_0864a9ce-c4c4-491d-aed3-24568507c0b4.jpg?v=1766397080"}],"url":"https:\/\/wpiinc.com\/es\/collections\/neurotransmitter-detection.oembed","provider":"World Precision Instruments","version":"1.0","type":"link"}