{"title":"Electrophysiology","description":"\u003ch1\u003e\u003cspan\u003eElectrophysiology\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eElectrophysiology helps researchers investigate how electrical signals are generated, transmitted and regulated in cells and tissues. Whether you’re recording from a single cell or studying activity across a neural network, a dependable setup helps you capture and interpret those signals. \u003c\/span\u003e\u003cspan\u003eExplore amplifiers for patch clamp, intracellular and extracellular recordings; stimulators for delivering controlled electrical pulses; and stimulus isolators for delivering stimulation while keeping the stimulation circuit electrically separate from the recording setup. Browse the range to find components for building a new system or expanding an existing one.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"74030-isolated-low-noise-bioamplifer-chassis","title":"Chasis bioamplificador aislado y de bajo ruido","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eChasis para el bioamplificador aislado y de bajo ruido\u003c\/h2\u003e\n\u003cp\u003eConsulta lo que necesitas saber \u003ca href=\"\/es\/blog\/post\/wpi-s-low-noise-amplifiers-outperform-cheap-imitations\"\u003eantes de comprar un amplificador\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePide un chasis y carcasa para fuente de alimentación (el artículo en esta página)\u003c\/li\u003e\n\u003cli\u003eSelecciona hasta 8 módulos (\u003ca href=\"\/es\/74020-isolated-low-noise-bioamplifier-single-channel-module\"\u003e\u003cstrong\u003eISO-DAM8A\u003c\/strong\u003e \u003c\/a\u003eo \u003ca href=\"\/es\/bridge8-bridge8-transducer-amplifier-module\"\u003e\u003cstrong\u003eBRIDGE8\u003c\/strong\u003e\u003c\/a\u003e)\u003c\/li\u003e\n\u003cli\u003ePide paneles en blanco (\u003ca href=\"\/es\/74050-isdb-blank-panels\"\u003e\u003cstrong\u003e74050\u003c\/strong\u003e\u003c\/a\u003e) para llenar ranuras vacías\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eVentajas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEl chasis acepta combinación de bioamplificadores y amplificadores de transductores\u003c\/li\u003e\n\u003cli\u003eCuenta flexible de canales (1–8) que permite expansión\u003c\/li\u003e\n\u003cli\u003eFiltro notch que elimina fuentes de ruido de la línea de corriente alterna\u003c\/li\u003e\n\u003cli\u003eAmplitud de salida con ganancia variable\u003c\/li\u003e\n\u003cli\u003eAmplio rango de salida de ±10V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAmplificación de biopotenciales usando microelectrodos metálicos\u003c\/li\u003e\n\u003cli\u003ePotenciales de campo en cortes cerebrales\u003c\/li\u003e\n\u003cli\u003eEAG (Electroantennograma)\u003c\/li\u003e\n\u003cli\u003eERG (Electrorretinograma)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEl \u003cstrong\u003eISO-DAM8A\u003c\/strong\u003e es un sistema compacto modular estándar para montaje en rack con amplificador de corriente continua. Cada canal está eléctricamente aislado de los demás y de tierra. No puede fluir corriente desde los terminales de entrada ni de los electrodos. El instrumento es intrínsecamente seguro y no puede causar ningún estímulo eléctrico ni descarga a la preparación. Además, se minimiza el ruido por bucle de tierra.\u003c\/p\u003e\n\u003ch2\u003eFiltros incluidos con el amplificador\u003c\/h2\u003e\n\u003cp\u003eLos sistemas pueden adquirirse con uno, dos, tres o hasta ocho módulos de preamplificador o combinados con módulos amplificadores de transductores \u003cstrong\u003eBridge8\u003c\/strong\u003e. Luego puedes seleccionar:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUna configuración adecuada de filtro pasa bajos, ganancia y compensación en el panel del amplificador del canal.\u003c\/li\u003e\n\u003cli\u003eFiltro notch añadido para reducir interferencias de frecuencia de línea.\u003c\/li\u003e\n\u003cli\u003ePre-amplificador opcional para etapa de cabeza (ganancia 10x) que permite grabación extracelular (DC) de bajo ruido con \u003cstrong\u003eIso-DAM8A\u003c\/strong\u003e y ofrece mayor ancho de banda de señal que un cable blindado de la misma longitud.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLa configuración del amplificador \u003cstrong\u003eIso-DAM8A\u003c\/strong\u003e y la etapa de cabeza es óptima para usar con nuestros \u003ca href=\"\/es\/products\/supplies-parts-accessories\/electrodes\/electrodes\"\u003emicroelectrodos metálicos\u003c\/a\u003e y puede configurarse fácilmente para muchas aplicaciones. Cada canal del amplificador tiene un conector coaxial (BNC) ubicado en el panel trasero.\u003c\/p\u003e\n\u003ch2\u003eConfiguración de tu sistema ISDB\u003c\/h2\u003e\n\u003cp\u003eEl chasis ISDB (\u003ca href=\"\/es\/74030-isolated-low-noise-bioamplifer-chassis\"\u003e\u003cstrong\u003e74030\u003c\/strong\u003e\u003c\/a\u003e) puede alojar hasta ocho módulos e incluye una fuente de alimentación. Puedes incluir cualquier combinación de módulos amplificadores de transductores \u003ca href=\"\/es\/bridge8-bridge8-transducer-amplifier-module\"\u003e\u003cstrong\u003eBRIDGE8\u003c\/strong\u003e\u003c\/a\u003e o módulos de canal único ISO-DAM8A (\u003ca href=\"\/es\/74020-isolated-low-noise-bioamplifier-single-channel-module\"\u003e\u003cstrong\u003e74020\u003c\/strong\u003e\u003c\/a\u003e). Si eliges menos de ocho módulos, debes pedir los paneles en blanco ISDB (\u003ca href=\"\/es\/74050-isdb-blank-panels\"\u003e\u003cstrong\u003e74050\u003c\/strong\u003e\u003c\/a\u003e) para llenar las ranuras vacías del chasis. Los bioamplificadores ISO-DAM8A incluyen un conector DIN de 8 pines con cable blindado sin terminar de 5 pies. Por favor, especifica el voltaje de línea al hacer el pedido.\u003c\/p\u003e\n\u003cp\u003eAl configurar tu sistema ISDB:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePide un chasis y carcasa para fuente de alimentación (\u003ca href=\"\/es\/74030-isolated-low-noise-bioamplifer-chassis\"\u003e\u003cstrong\u003e74030\u003c\/strong\u003e\u003c\/a\u003e)\u003c\/li\u003e\n\u003cli\u003eSelecciona hasta 8 módulos (\u003ca href=\"\/es\/74020-isolated-low-noise-bioamplifier-single-channel-module\"\u003e\u003cstrong\u003eISO-DAM8A\u003c\/strong\u003e \u003c\/a\u003eo \u003ca href=\"\/es\/bridge8-bridge8-transducer-amplifier-module\"\u003e\u003cstrong\u003eBRIDGE8\u003c\/strong\u003e\u003c\/a\u003e)\u003c\/li\u003e\n\u003cli\u003ePide paneles en blanco (\u003ca href=\"\/es\/74050-isdb-blank-panels\"\u003e\u003cstrong\u003e74050\u003c\/strong\u003e\u003c\/a\u003e) para llenar ranuras vacías\u003c\/li\u003e\n\u003cli\u003eISO-DAM8A \u003ca href=\"\/es\/74020-isolated-low-noise-bioamplifier-single-channel-module\"\u003e\u003cstrong\u003e74020\u003c\/strong\u003e \u003c\/a\u003ees un amplificador de corriente continua\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSistema completo de amplificador de ocho canales con chasis 74030 mostrando ocho módulos \u003ca href=\"\/es\/74020-isolated-low-noise-bioamplifier-single-channel-module\"\u003e74020\u003c\/a\u003e (ISODAM8A) instalados\u003cbr\u003e*También disponible para módulos amplificadores de transductores BRIDGE8 y paneles en blanco (74050).\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/Iso-DAM8a-full_7f8b430e-57f7-43a1-a0bb-cc0a58b4b19f.jpg?v=1765943236\" alt=\"Iso-DAM8a\" width=\"500\" height=\"205\"\u003e\u003c\/p\u003e\n\u003cp\u003eLa foto ilustra un sistema completo de amplificador y se muestra con el chasis 74030 y ocho módulos amplificadores ISO-DAM8A (74020).\u003c\/p\u003e\n\u003cp\u003e*Los módulos se venden por separado.  \u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr bgcolor=\"#e4e4e4\"\u003e\n\u003ctd\u003eFuente de alimentación\u003c\/td\u003e\n\u003ctd\u003eAdaptador de corriente 110-120V\/60Hz o 220-240\/50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensiones de la carcasa\u003c\/td\u003e\n\u003ctd\u003e7 x 17 x 9.2˝ (18 x 43 x 23 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e4e4e4\"\u003e\n\u003ctd\u003ePeso para envío\u003c\/td\u003e\n\u003ctd\u003e10–21 lb. (4.5–9.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42265635651674,"sku":"74030","price":2800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/isdb_e0309281-674f-41e9-b88a-cedf625e29be.jpg?v=1766393128"},{"product_id":"var-2273-constant-current-stimulus-isolator","title":"Aislador de Estímulo de Corriente Constante","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003ePulsos bipolares automatizados para carga neta cero en preparaciones biológicas\u003c\/h2\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCorriente constante\u003c\/li\u003e\n\u003cli\u003eModos de estimulación unipolar y bipolar\u003c\/li\u003e\n\u003cli\u003eAlarma incorporada de no cumplimiento\u003c\/li\u003e\n\u003cli\u003eLa entrada está ópticamente aislada\u003c\/li\u003e\n\u003cli\u003eDisparo TTL estándar\u003c\/li\u003e\n\u003cli\u003eModo de prueba CC\u003c\/li\u003e\n\u003cli\u003eAlimentado por baterías alcalinas o recargables de 9 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOpciones\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #0081c2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eNúmero de parte\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eDescripción\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eTipo de batería\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eIncluye cargador\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eA365RC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA365R con un cargador de baterías A362\u003c\/td\u003e\n\u003ctd\u003eBatería recargable\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eSí\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSYS-A365R\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAislador de alto voltaje, bipolar\u003c\/td\u003e\n\u003ctd\u003eBatería recargable\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSYS-A365D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAislador de alto voltaje, bipolar\u003c\/td\u003e\n\u003ctd\u003eBaterías alcalinas\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e_\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eBeneficios\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEl voltaje de cumplimiento es de 100V o más\u003c\/li\u003e\n\u003cli\u003eEl modo bipolar genera automáticamente pulsos alternos positivos y negativos desde entrada TTL\u003c\/li\u003e\n\u003cli\u003eEl modo de prueba simplifica la verificación del rendimiento\u003c\/li\u003e\n\u003cli\u003eEl aislamiento óptico mejora la seguridad de la preparación y reduce la susceptibilidad al ruido\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrofisiología\u003c\/li\u003e\n\u003cli\u003eEstimulación de cortes cerebrales\u003c\/li\u003e\n\u003cli\u003e\nEstimulación cerebral y del SNC \u003cem\u003ein vivo\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eActivado por comandos lógicos convencionales, Modelo \u003cstrong\u003eA365\u003c\/strong\u003e puede ser activado por cualquier generador de pulsos, estimulador o salida de computadora con pulsos bipolares automatizados para carga neta cero en preparaciones biológicas.\u003c\/p\u003e\n\u003ch2\u003eAlarmas audibles de tono dual\u003c\/h2\u003e\n\u003cp\u003eUn tono suena cuando se detecta un circuito de electrodo abierto o cuando se alcanza el cumplimiento del sistema. Un segundo tono opcional suena cuando se aplica una señal a la entrada. También se proporciona un interruptor de prueba para verificar la carga de la batería.\u003c\/p\u003e\n\u003ch2\u003eEntrega de corriente hasta 10 mA a más de 100V\u003c\/h2\u003e\n\u003cp\u003eLas corrientes de estímulo se ajustan usando una perilla de control de tres dígitos y un interruptor de rango de tres posiciones. La corriente de salida sigue los ajustes de control con una precisión mejor al 1%. La corriente de salida es independiente de la carga, y se desarrolla automáticamente un voltaje suficiente para impulsar la corriente deseada a través de la carga, sujeto solo a los límites de cumplimiento. Modelo \u003cstrong\u003eA360LA\u003c\/strong\u003e produce hasta 10 mA de corriente, en tres rangos, con más de 100 V de cumplimiento.\u003c\/p\u003e\n\u003ch2\u003ePolaridad de Salida Bipolar\u003c\/h2\u003e\n\u003cp\u003eLa polaridad de salida se determina mediante un interruptor pulsador en el panel frontal. La corriente bipolar se alterna mediante la forma de onda de comando, configurando pulsos alternos como positivos o negativos.\u003c\/p\u003e\n\u003ch2\u003eAlimentación\u003c\/h2\u003e\n\u003cp\u003eEste\u003cstrong\u003e\u003ca href=\"\/es\/index.php?src=directory\u0026amp;view=products\u0026amp;srctype=detail\u0026amp;refno=2273\u0026amp;category=Physiology\"\u003e \u003c\/a\u003eA365RC\u003c\/strong\u003e Aislador de Estímulos incluye tanto el \u003cstrong\u003eA365R\u003c\/strong\u003e Aislador de Estímulos como el \u003cstrong\u003eA362\u003c\/strong\u003e cargador de baterías. El recargable \u003cstrong\u003eA365R\u003c\/strong\u003e se suministra con un paquete de baterías de hidruro metálico de níquel. El \u003ca href=\"\/es\/sys-a362-a362-battery-charger\"\u003e\u003cstrong\u003eA362\u003c\/strong\u003e Cargador de Baterías\u003c\/a\u003e es necesario con el \u003cstrong\u003eA365R\u003c\/strong\u003e. \u003c\/p\u003e\n\u003cp\u003e NOTA: No destinado para uso humano.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/A365_IMs.pdf\" target=\"_self\"\u003eManual de instrucciones A365\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:specifications --\u003e\n\u003ctable cellpadding=\"2\" cellspacing=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFORMA DE ONDA DE SALIDA\u003c\/td\u003e\n\u003ctd\u003eCC o pulso de corriente\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eRANGOS DE CORRIENTE DE SALIDA\u003c\/td\u003e\n\u003ctd\u003e0.1, 1.0 y 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eERROR DE AMPLITUD DE CORRIENTE\u003c\/td\u003e\n\u003ctd\u003e0.5% de la escala completa, máx.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eRESOLUCIÓN ACTUAL\u003c\/td\u003e\n\u003ctd\u003e0.1% de la escala completa, típico\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEXCURSIÓN DE VOLTAJE DE CARGA DE SALIDA (CUMPLIMIENTO)\u003c\/td\u003e\n\u003ctd\u003e100 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eUMBRAL DE COMANDO EXTERNO\u003c\/td\u003e\n\u003ctd\u003e5 V a 3 mA, mínimo 10 V, máximo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUMBRAL DE DISPARO\u003c\/td\u003e\n\u003ctd\u003e2.0 V a 0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOLARIDAD DE SALIDA\u003c\/td\u003e\n\u003ctd\u003eReversible, interruptor manual o automático\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eTIEMPO DE SUBIDA Y RETARDO DE CORRIENTE\u003c\/td\u003e\n\u003ctd\u003e6 μs, típico (carga de 1 KΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTIEMPO DE CAÍDA Y RETARDO DE CORRIENTE\u003c\/td\u003e\n\u003ctd\u003e10 μs, típico (carga de 1 KΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eRESISTENCIA DE SALIDA A TIERRA\u003c\/td\u003e\n\u003ctd\u003e10\u003csup\u003e12 \u003c\/sup\u003eΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOPTOACOPLADOR\u003c\/td\u003e\n\u003ctd\u003e2500 V, voltaje mínimo de ruptura nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eALIMENTACIÓN: Modelo A365D (pila seca)\u003c\/td\u003e\n\u003ctd\u003e16 baterías alcalinas de 9 V incluidas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eALIMENTACIÓN: Modelo A365R (recargable)\u003c\/td\u003e\n\u003ctd\u003e16 baterías recargables NiMH de 9 V incluidas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eDIMENSIONES\u003c\/td\u003e\n\u003ctd\u003e8.5 x 3.5 x 5 in. (22 x 9 x 12 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePESO DE ENVÍO\u003c\/td\u003e\n\u003ctd\u003e4 lb. (1.8 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cb\u003eYavich, L., Tanila, H., Vepsäläinen, S., \u0026amp; Jäkälä, P. (s.f.).\u003c\/b\u003e Neurobiología de la enfermedad Papel de la ␣-sinucleína en el reclutamiento presináptico de dopamina. \u003ca href=\"https:\/\/doi.org\/10.1523\/JNEUROSCI.2559-04.2004\"\u003ehttps:\/\/doi.org\/10.1523\/JNEUROSCI.2559-04.2004\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIremonger, K. J., Anderson, T. R., Hu, B., \u0026amp; Kiss, Z. H. T. (s.f.).\u003c\/b\u003e Mecanismos celulares que previenen la activación sostenida de la corteza durante la estimulación subcortical de alta frecuencia. \u003ca href=\"https:\/\/doi.org\/10.1152\/jn.00105.2006\"\u003ehttps:\/\/doi.org\/10.1152\/jn.00105.2006\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eRowland, N. C., \u0026amp; Jaeger, D. (s.f.).\u003c\/b\u003e Las respuestas a la estimulación táctil en las neuronas del núcleo cerebeloso profundo resultan de la activación recurrente en múltiples vías. \u003ca href=\"https:\/\/doi.org\/10.1152\/jn.01100.2007\"\u003ehttps:\/\/doi.org\/10.1152\/jn.01100.2007\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eD ’ambrosio, R., Gordon, D. S., Winn, H. R., ’ambrosio, D., Raimondo, D. S., Gordon, H., \u0026amp; Richard, W. (s.f.).\u003c\/b\u003e Papel diferencial del canal KIR y la bomba Na ϩ \/K ϩ en la regulación del K ϩ extracelular en el hipocampo de rata. \u003ca href=\"https:\/\/doi.org\/10.1152\/jn.00240.2001\"\u003ehttps:\/\/doi.org\/10.1152\/jn.00240.2001\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHuda, R., Mccrimmon, D. R., \u0026amp; Martina, M. (s.f.).\u003c\/b\u003e La modulación del pH de los transportadores gliales de glutamato regula la transmisión sináptica en el núcleo del tracto solitario.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eChen, Y., Beffert, U., Ertunc, M., Tang, T.-S., Kavalali, E. T., Bezprozvanny, I., \u0026amp; Herz, J. (s.f.).\u003c\/b\u003e Desarrollo\/Plasticidad\/Reparación Reelin modula la actividad del receptor NMDA en neuronas corticales. \u003ca href=\"https:\/\/doi.org\/10.1523\/JNEUROSCI.1951-05.2005\"\u003ehttps:\/\/doi.org\/10.1523\/JNEUROSCI.1951-05.2005\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eD ’ambrosio, R., Wenzel, J., Schwartzkroin, P. A., Mckhann Ii, G. M., \u0026amp; Janigro, D. (s.f.).\u003c\/b\u003e Especialización funcional y segregación topográfica de los astrocitos hipocampales.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eD ’ambrosio, R., Maris, D. O., Grady, M. S., Winn, H. R., \u0026amp; Janigro, D. (s.f.).\u003c\/b\u003e Homeostasis de K ؉ alterada y propiedades electrofisiológicas modificadas de la glía hipocampal postraumática.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eJi, H., \u0026amp; Shepard, P. D. (n.d.).\u003c\/b\u003e Behavioral\/Systems\/Cognitive La estimulación de la habenula lateral inhibe las neuronas dopaminérgicas del mesencéfalo en ratas mediante un mecanismo mediado por receptores GABA A. \u003ca href=\"https:\/\/doi.org\/10.1523\/JNEUROSCI.0958-07.2007\"\u003ehttps:\/\/doi.org\/10.1523\/JNEUROSCI.0958-07.2007\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eLee, E., Hong, J., Park, Y.-G., Chae, S., Kim, Y., \u0026amp; Kim, D. (2015).\u003c\/b\u003e La actividad cortical del hemisferio izquierdo modula los efectos del estrés en el comportamiento social. \u003ci\u003eScientific Reports\u003c\/i\u003e, \u003ci\u003e5\u003c\/i\u003e, 13342. \u003ca href=\"https:\/\/doi.org\/10.1038\/srep13342\"\u003ehttps:\/\/doi.org\/10.1038\/srep13342\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eGindrat, A.-D., Quairiaux, C., Britz, J., Brunet, D., Lanz, F., Michel, C. M., \u0026amp; Rouiller, E. M. (2015).\u003c\/b\u003e Mapeo EEG de todo el cuero cabelludo de potenciales evocados somatosensoriales en monos macacos. \u003ci\u003eBrain Structure \u0026amp; Function\u003c\/i\u003e, \u003ci\u003e220\u003c\/i\u003e(4), 2121–2142. \u003ca href=\"https:\/\/doi.org\/10.1007\/s00429-014-0776-y\"\u003ehttps:\/\/doi.org\/10.1007\/s00429-014-0776-y\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAvila, I., \u0026amp; Lin, S.-C. (2014).\u003c\/b\u003e Señal de saliencia motivacional en el prosencéfalo basal está acoplada con una velocidad de decisión más rápida y precisa. \u003ci\u003ePLoS Biology\u003c\/i\u003e, \u003ci\u003e12\u003c\/i\u003e(3), e1001811. \u003ca href=\"https:\/\/doi.org\/10.1371\/journal.pbio.1001811\"\u003ehttps:\/\/doi.org\/10.1371\/journal.pbio.1001811\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNguyen, D. P., \u0026amp; Lin, S.-C. (2014).\u003c\/b\u003e Un potencial relacionado con eventos en la corteza frontal impulsado por el prosencéfalo basal. \u003ci\u003eELife\u003c\/i\u003e, \u003ci\u003e3\u003c\/i\u003e, e02148. Recuperado de \u003ca rel=\"noopener\" href=\"https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC3974155\/\" target=\"_blank\"\u003ehttps:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC3974155\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHerrera, C., Directores, R., Panetsos, F., Carlos, P., \u0026amp; Trueba, A. (2014).\u003c\/b\u003e TESIS DOCTORAL Efectos de la estimulación artificial de un nervio periférico seccionado sobre la vía somatosensorial desaferentizada de la rata.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eYounce, J. R., Albaugh, D. L., \u0026amp; Shih, Y.-Y. I. (2014).\u003c\/b\u003e Estimulación cerebral profunda con fMRI simultáneo en roedores. \u003ci\u003eJournal of Visualized Experiments\u003c\/i\u003e, (84), e51271–e51271. \u003ca href=\"https:\/\/doi.org\/10.3791\/51271\"\u003ehttps:\/\/doi.org\/10.3791\/51271\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOulad Ben Taib, N., \u0026amp; Manto, M. (2013).\u003c\/b\u003e Series de estimulación DC epidural del cerebelo ajustan la excitabilidad corticomotora. \u003ci\u003eNeural Plasticity\u003c\/i\u003e, \u003ci\u003e2013\u003c\/i\u003e(10), 1–12. \u003ca href=\"https:\/\/doi.org\/10.1155\/2013\/613197\"\u003ehttps:\/\/doi.org\/10.1155\/2013\/613197\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSyvänen, S., Russmann, V., Verbeek, J., Eriksson, J., Labots, M., Zellinger, C., … Potschka, H. (2013).\u003c\/b\u003e Imagen PET con [11C]quinidina y [11C]laniquidar en un modelo crónico de epilepsia en roedores: Impacto de la epilepsia y la respuesta al medicamento. \u003ci\u003eNuclear Medicine and Biology\u003c\/i\u003e, \u003ci\u003e40\u003c\/i\u003e(6), 764–775. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.nucmedbio.2013.05.008\"\u003ehttps:\/\/doi.org\/10.1016\/j.nucmedbio.2013.05.008\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSchroder, E. A., Lefta, M., Zhang, X., Bartos, D. C., Feng, H.-Z., Zhao, Y., … Delisle, B. P. (2013).\u003c\/b\u003e El reloj molecular del cardiomiocito, regulación de Scn5a y susceptibilidad a arritmias. \u003ci\u003eAmerican Journal of Physiology. Cell Physiology\u003c\/i\u003e, \u003ci\u003e304\u003c\/i\u003e(10), C954-65. \u003ca href=\"https:\/\/doi.org\/10.1152\/ajpcell.00383.2012\"\u003ehttps:\/\/doi.org\/10.1152\/ajpcell.00383.2012\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSchmuckermair, C., Gaburro, S., Sah, A., Landgraf, R., Sartori, S. B., \u0026amp; Singewald, N. (2013).\u003c\/b\u003e Efectos conductuales y neurobiológicos de la estimulación cerebral profunda en un modelo murino de comportamiento con alta ansiedad y depresión. \u003ci\u003eNeuropsychopharmacology : Official Publication of the American College of Neuropsychopharmacology\u003c\/i\u003e, \u003ci\u003e38\u003c\/i\u003e(7), 1234–1244. \u003ca href=\"https:\/\/doi.org\/10.1038\/npp.2013.21\"\u003ehttps:\/\/doi.org\/10.1038\/npp.2013.21\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDalby-Brown, W., Jessen, C., Hougaard, C., Jensen, M. L., Jacobsen, T. A., Nielsen, K. S., … Jørgensen, S. (2013).\u003c\/b\u003e Caracterización de un nuevo modulador positivo de alta potencia de los canales Kv7. \u003ci\u003eEuropean Journal of Pharmacology\u003c\/i\u003e, \u003ci\u003e709\u003c\/i\u003e(1–3), 52–63. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.ejphar.2013.03.039\"\u003ehttps:\/\/doi.org\/10.1016\/j.ejphar.2013.03.039\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eLicko, T., Seeger, N., Zellinger, C., Russmann, V., Matagne, A., \u0026amp; Potschka, H. (2013). \u003c\/b\u003eEl tratamiento con lacosamida tras un estado epiléptico atenúa la pérdida neuronal y las alteraciones en la neurogénesis hipocampal en un modelo eléctrico de estado epiléptico en ratas. \u003ci\u003eEpilepsia\u003c\/i\u003e, \u003ci\u003e54\u003c\/i\u003e(7), 1176–1185. \u003ca href=\"https:\/\/doi.org\/10.1111\/epi.12196\"\u003ehttps:\/\/doi.org\/10.1111\/epi.12196\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAtherton, J. F., Menard, A., Urbain, N., \u0026amp; Bevan, M. D. (2013).\u003c\/b\u003e Depresión a corto plazo de la transmisión sináptica globo pálido externo-núcleo subtalámico e implicaciones para el patrón de actividad subtalámica. \u003ci\u003eThe Journal of Neuroscience : The Official Journal of the Society for Neuroscience\u003c\/i\u003e, \u003ci\u003e33\u003c\/i\u003e(17), 7130–7144. \u003ca href=\"https:\/\/doi.org\/10.1523\/JNEUROSCI.3576-12.2013\"\u003ehttps:\/\/doi.org\/10.1523\/JNEUROSCI.3576-12.2013\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSaha, D., Leong, K., Katta, N., \u0026amp; Raman, B. (2013).\u003c\/b\u003e Métodos de grabación multiunidad para caracterizar la actividad neuronal en los circuitos olfativos de la langosta (\u0026amp;lt;em\u0026amp;gt;Schistocerca Americana\u0026amp;lt;\/em\u0026amp;gt;). \u003ci\u003eJournal of Visualized Experiments\u003c\/i\u003e, (71), e50139–e50139. \u003ca href=\"https:\/\/doi.org\/10.3791\/50139\"\u003ehttps:\/\/doi.org\/10.3791\/50139\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHuda, R., McCrimmon, D. R., \u0026amp; Martina, M. (2013).\u003c\/b\u003e La modulación del pH de los transportadores gliales de glutamato regula la transmisión sináptica en el núcleo del tracto solitario. \u003ci\u003eJournal of Neurophysiology\u003c\/i\u003e, \u003ci\u003e110\u003c\/i\u003e(2), 368–377. \u003ca href=\"https:\/\/doi.org\/10.1152\/jn.01074.2012\"\u003ehttps:\/\/doi.org\/10.1152\/jn.01074.2012\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSonner, P. M., \u0026amp; Ladle, D. R. (2013).\u003c\/b\u003e Desarrollo postnatal temprano de la inhibición presináptica gabaérgica de las conexiones aferentes proprioceptivas Ia en la médula espinal de ratón. \u003ci\u003eJournal of Neurophysiology\u003c\/i\u003e, \u003ci\u003e109\u003c\/i\u003e(8), 2118–2128. \u003ca href=\"https:\/\/doi.org\/10.1152\/jn.00783.2012\"\u003ehttps:\/\/doi.org\/10.1152\/jn.00783.2012\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eZhu, Z., Sierra, A., Burnett, C. M.-L. L., Chen, B., Subbotina, E., Koganti, S. R. K., … Zingman, L. V. (2013).\u003c\/b\u003e Los canales de potasio sensibles al ATP en la sarcolema modulan la función del músculo esquelético bajo cargas de trabajo de baja intensidad. \u003ci\u003eThe Journal of General Physiology\u003c\/i\u003e, \u003ci\u003e143\u003c\/i\u003e(1), 119–134. \u003ca href=\"https:\/\/doi.org\/10.1085\/jgp.201311063\"\u003ehttps:\/\/doi.org\/10.1085\/jgp.201311063\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eBrenowitz, S. D., \u0026amp; Regehr, W. G. (2012).\u003c\/b\u003e Imagen presináptica de fibras de proyección mediante inyección in vivo de indicadores de calcio conjugados con dextrano. \u003ci\u003eCold Spring Harbor Protocols\u003c\/i\u003e, \u003ci\u003e2012\u003c\/i\u003e(4), 465–471. \u003ca href=\"https:\/\/doi.org\/10.1101\/pdb.prot068551\"\u003ehttps:\/\/doi.org\/10.1101\/pdb.prot068551\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eLi, W., Janardhan, A. H., Fedorov, V. V, Sha, Q., Schuessler, R. B., \u0026amp; Efimov, I. R. (2011).\u003c\/b\u003e La terapia de desfibrilación auricular multietapa de baja energía termina la fibrilación auricular con menos energía que una descarga única. \u003ci\u003eCirculation. Arrhythmia and Electrophysiology\u003c\/i\u003e, \u003ci\u003e4\u003c\/i\u003e(6), 917–925. \u003ca href=\"https:\/\/doi.org\/10.1161\/CIRCEP.111.965830\"\u003ehttps:\/\/doi.org\/10.1161\/CIRCEP.111.965830\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eMathis, D. M., Furman, J. L., \u0026amp; Norris, C. M. (2011).\u003c\/b\u003e Preparación de cortes agudos de hipocampo de ratas y ratones transgénicos para el estudio de alteraciones sinápticas durante el envejecimiento y la patología amiloide. \u003ci\u003eJournal of Visualized Experiments\u003c\/i\u003e, (49), e2330–e2330. \u003ca href=\"https:\/\/doi.org\/10.3791\/2330\"\u003ehttps:\/\/doi.org\/10.3791\/2330\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eManto, M. U., Hampe, C. S., Rogemond, V., \u0026amp; Honnorat, J. (2011).\u003c\/b\u003e Implicaciones respectivas de los anticuerpos contra la descarboxilasa del glutamato en el síndrome de persona rígida y la ataxia cerebelosa. \u003ci\u003eOrphanet Journal of Rare Diseases\u003c\/i\u003e, \u003ci\u003e6\u003c\/i\u003e(1), 3. \u003ca href=\"https:\/\/doi.org\/10.1186\/1750-1172-6-3\"\u003ehttps:\/\/doi.org\/10.1186\/1750-1172-6-3\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eKim, J., Woo, J., Park, Y.-G., Chae, S., Jo, S., Choi, J. W., … Kim, D. (2011).\u003c\/b\u003e Los canales de Ca\u003csup\u003e2\u003c\/sup\u003e+ tipo T talámicos median disfunciones del lóbulo frontal causadas por un daño similar a la hipoxia en la corteza prefrontal. \u003ci\u003eThe Journal of Neuroscience : The Official Journal of the Society for Neuroscience\u003c\/i\u003e, \u003ci\u003e31\u003c\/i\u003e(11), 4063–4073. \u003ca href=\"https:\/\/doi.org\/10.1523\/JNEUROSCI.4493-10.2011\"\u003ehttps:\/\/doi.org\/10.1523\/JNEUROSCI.4493-10.2011\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSeo, J. H., Jang, I. K., Kim, H., Yang, M. S., Lee, J. E., Kim, H. E., … Cho, S.-R. (2011).\u003c\/b\u003e La inmunomodulación temprana por células madre mesenquimales trasplantadas por vía intravenosa promueve la recuperación funcional en ratas con lesión de la médula espinal. \u003ci\u003eCell Medicine\u003c\/i\u003e, \u003ci\u003e2\u003c\/i\u003e(2), 55–67. \u003ca href=\"https:\/\/doi.org\/10.3727\/215517911X582788\"\u003ehttps:\/\/doi.org\/10.3727\/215517911X582788\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePelkonen, A., Hiltunen, M., Kiianmaa, K., \u0026amp; Yavich, L. (2010).\u003c\/b\u003e Desbordamiento estimulado de dopamina y expresión de alfa-sinucleína en el núcleo accumbens core distinguen ratas criadas para preferencia diferencial por etanol. \u003ci\u003eJournal of Neurochemistry\u003c\/i\u003e, \u003ci\u003e114\u003c\/i\u003e(4), 1168–1176. \u003ca href=\"https:\/\/doi.org\/10.1111\/j.1471-4159.2010.06844.x\"\u003ehttps:\/\/doi.org\/10.1111\/j.1471-4159.2010.06844.x\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFoust, A. J., Schei, J. L., Rojas, M. J., \u0026amp; Rector, D. M. (2008).\u003c\/b\u003e Análisis de ruido in vitro e in vivo para el registro neural óptico. \u003ci\u003eJournal of Biomedical Optics\u003c\/i\u003e, \u003ci\u003e13\u003c\/i\u003e(4), 044038. \u003ca href=\"https:\/\/doi.org\/10.1117\/1.2952295\"\u003ehttps:\/\/doi.org\/10.1117\/1.2952295\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSchei, J. L., McCluskey, M. D., Foust, A. J., Yao, X.-C., \u0026amp; Rector, D. M. (2008). \u003c\/b\u003ePropagación del potencial de acción imagenada con alta resolución temporal mediante microscopía de video en infrarrojo cercano y luz polarizada. \u003ci\u003eNeuroImage\u003c\/i\u003e, \u003ci\u003e40\u003c\/i\u003e(3), 1034–1043. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.neuroimage.2007.12.055\"\u003ehttps:\/\/doi.org\/10.1016\/j.neuroimage.2007.12.055\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFoust, A. J., \u0026amp; Rector, D. M. (2007). \u003c\/b\u003eSeparando ópticamente la hinchazón neural y la despolarización. \u003ci\u003eNeuroscience\u003c\/i\u003e, \u003ci\u003e145\u003c\/i\u003e(3), 887–899. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.neuroscience.2006.12.068\"\u003ehttps:\/\/doi.org\/10.1016\/j.neuroscience.2006.12.068\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eJi, H., \u0026amp; Shepard, P. D. (2007).\u003c\/b\u003e La estimulación de la habenula lateral inhibe las neuronas dopaminérgicas del mesencéfalo de rata mediante un mecanismo mediado por receptores GABA(A). \u003ci\u003eThe Journal of Neuroscience : The Official Journal of the Society for Neuroscience\u003c\/i\u003e, \u003ci\u003e27\u003c\/i\u003e(26), 6923–6930. \u003ca href=\"https:\/\/doi.org\/10.1523\/JNEUROSCI.0958-07.2007\"\u003ehttps:\/\/doi.org\/10.1523\/JNEUROSCI.0958-07.2007\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eLee, B. H., Lee, K. H., Yoon, D. H., Kim, U. J., Hwang, Y. S., Park, S. K., … Jahng, T. (2005).\u003c\/b\u003e Efectos de la metilprednisolona en la conducción neural de los potenciales evocados motores en ratas con lesión medular. \u003ci\u003eJournal of Korean Medical Science\u003c\/i\u003e, \u003ci\u003e20\u003c\/i\u003e(1), 132–138. \u003ca href=\"https:\/\/doi.org\/10.3346\/jkms.2005.20.1.132\"\u003ehttps:\/\/doi.org\/10.3346\/jkms.2005.20.1.132\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAnderson, T., Hu, B., Pittman, Q., \u0026amp; Kiss, Z. H. T. (2004).\u003c\/b\u003e Mecanismos de la estimulación cerebral profunda: un estudio intracelular en el tálamo de rata. \u003ci\u003eThe Journal of Physiology\u003c\/i\u003e, \u003ci\u003e559\u003c\/i\u003e(1), 301–313. \u003ca href=\"https:\/\/doi.org\/10.1113\/jphysiol.2004.064998\"\u003ehttps:\/\/doi.org\/10.1113\/jphysiol.2004.064998\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSokolow, S., Manto, M., Gailly, P., Molgó, J., Vandebrouck, C., Vanderwinden, J.-M., … Schurmans, S. (2004).\u003c\/b\u003e Transmisión neuromuscular deteriorada y necrosis de fibras musculares esqueléticas en ratones sin intercambiador Na\/Ca 3. \u003ci\u003eJournal of Clinical Investigation\u003c\/i\u003e, \u003ci\u003e113\u003c\/i\u003e(2), 265–273. \u003ca href=\"https:\/\/doi.org\/10.1172\/JCI18688\"\u003ehttps:\/\/doi.org\/10.1172\/JCI18688\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eD’Ambrosio, R., Fairbanks, J. P., Fender, J. S., Born, D. E., Doyle, D. L., \u0026amp; Miller, J. W. (2004). \u003c\/b\u003eEpilepsia postraumática tras lesión por percusión de fluido en la rata. \u003ci\u003eBrain : A Journal of Neurology\u003c\/i\u003e, \u003ci\u003e127\u003c\/i\u003e(Pt 2), 304–314. \u003ca href=\"https:\/\/doi.org\/10.1093\/brain\/awh038\"\u003ehttps:\/\/doi.org\/10.1093\/brain\/awh038\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eShaw, B. K., \u0026amp; Kennedy, G. G. (2002).\u003c\/b\u003e Evidencia de diferencias entre especies en el patrón de distribución del receptor de andrógenos en relación con diferencias entre especies en un comportamiento dependiente de andrógenos. \u003ci\u003eJournal of Neurobiology\u003c\/i\u003e, \u003ci\u003e52\u003c\/i\u003e(3), 203–220. \u003ca href=\"https:\/\/doi.org\/10.1002\/neu.10079\"\u003ehttps:\/\/doi.org\/10.1002\/neu.10079\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eYavich, L., \u0026amp; Tiihonen, J. (2000).\u003c\/b\u003e El etanol modula la liberación evocado de dopamina en el núcleo accumbens de ratón: dependencia del estrés social y la dosis. \u003ci\u003eEuropean Journal of Pharmacology\u003c\/i\u003e, \u003ci\u003e401\u003c\/i\u003e(3), 365–373. Recuperado de \u003ca href=\"http:\/\/www.safetylit.org\/citations\/index.php?fuseaction=citations.viewdetails\u0026amp;citationIds%5B%5D=citjournalarticle_271069_38\"\u003ehttp:\/\/www.safetylit.org\/citations\/index.php?fuseaction=citations.viewdetails\u0026amp;citationIds%5B%5D=citjournalarticle_271069_38\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eKnisley, S. B., Trayanova, N., \u0026amp; Aguel, F. (1999).\u003c\/b\u003e Roles del campo eléctrico y la estructura de la fibra en la estimulación eléctrica cardíaca. \u003ci\u003eBiophysical Journal\u003c\/i\u003e, \u003ci\u003e77\u003c\/i\u003e(3), 1404–1417. \u003ca href=\"https:\/\/doi.org\/10.1016\/S0006-3495(99)76989-4\"\u003ehttps:\/\/doi.org\/10.1016\/S0006-3495(99)76989-4\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Alcalino","offer_id":42266068615258,"sku":"SYS-A365D","price":1800.0,"currency_code":"USD","in_stock":true},{"title":"Recargable","offer_id":42266068582490,"sku":"SYS-A365R","price":2300.0,"currency_code":"USD","in_stock":true},{"title":"Recargable con cargador","offer_id":42266068648026,"sku":"A365RC","price":2700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/a365_1_fc747f0d-6742-4e53-b046-ddaebb5c1dcc.jpg?v=1766396620"},{"product_id":"sys-a382-battery-charger","title":"Cargador de Batería","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eCargador innovador de 3 pasos que emplea cargas rápida, media y de mantenimiento\u003c\/li\u003e\r\n\u003cli\u003eCarga con una corriente baja y segura, extendiendo considerablemente la vida útil de la batería\u003c\/li\u003e\r\n\u003cli\u003ePara usar solo con baterías en el Aislador de Estímulos A385\u003c\/li\u003e\r\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/A382-IM.pdf\"\u003eManual de instrucciones A382\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ePOTENCIA\u003c\/td\u003e\r\n\u003ctd\u003e95-135 V o 220-240 V, 50\/60 Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eDIMENSIONES\u003c\/td\u003e\r\n\u003ctd\u003e8.5 x 3.5 x 5 pulg (22 x 9 x 12 cm)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ePESO DE ENVÍO\u003c\/td\u003e\r\n\u003ctd\u003e5 lb (2.3 kg)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266239172698,"sku":"SYS-A382","price":975.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/a382-front_e2948864-4042-4264-8ad1-ce6b91ddd557.jpg?v=1766399584"},{"product_id":"var-su-dpatch-dpatch-system","title":"Sistema dPatch","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eOpciones\u003c\/h2\u003e\n\u003ctable width=\"100%\" style=\"width: 100%;\" class=\"product-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 15.4776%;\"\u003e\u003cstrong\u003eCódigo de pedido\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 38.4522%;\"\u003e\u003cstrong\u003eDescripción\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 46.0701%;\"\u003e\u003cstrong\u003eDetalles\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15.4776%;\"\u003eSU-DPATCH\u003c\/td\u003e\n\u003ctd style=\"width: 38.4522%;\"\u003eSistema dPatch con un cabezal y preamplificador\u003c\/td\u003e\n\u003ctd style=\"width: 46.0701%;\"\u003eIncluye: sistema dPatch con un cabezal y preamplificador, soporte para pipeta 505671, celda modelo, terminal de tornillo para salidas digitales, hardware para montaje en rack; suite de software SutterPatch® con licencia Igor Pro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 15.4776%;\"\u003eSU-DPATCH-2\u003c\/td\u003e\n\u003ctd style=\"width: 38.4522%;\"\u003eSistema dPatch con dos cabezales y preamplificador\u003c\/td\u003e\n\u003ctd style=\"width: 46.0701%;\"\u003eIncluye: sistema dPatch con dos cabezales y preamplificadores, dos soportes para pipetas 505671, dos celdas modelo, terminales de tornillo para salidas digitales, hardware para montaje en rack; suite de software SutterPatch® con licencia Igor Pro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSOPORTE LEGENDARIO\u003c\/h2\u003e\n\u003cp\u003eSutter tiene una larga historia de respaldo a nuestros productos y de mejorarlos continuamente. Mientras otros amplificadores en el mercado no se han actualizado en 20 años, el dPatch seguirá siendo desarrollado y soportado MUCHO tiempo en el futuro. Todos nuestros productos se fabrican en USA, y ofrecemos soporte gratuito si necesita ayuda.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eTASA DE MUESTREO DE 5 MHz, HASTA 22 BITS DE RESOLUCIÓN\u003c\/h2\u003e\n\u003cp\u003eUna característica única del dPatch es el sistema de muestreo de datos del cabezal. Cada cabezal se muestrea continuamente a 5 MHz. El filtrado de salida tiene trece configuraciones entre 100 Hz y 1 MHz. Se logra una resolución de 18 bits a 1 MHz. Para configuraciones de filtro más bajas, el submuestreo automático aumenta la resolución mientras optimiza las tasas de datos. Con un ancho de banda de 1 kHz, el sistema dPatch proporciona una resolución de señal mejor que 22 bits.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eNO SE REQUIERE REFRIGERACIÓN ACTIVA\u003c\/h2\u003e\n\u003cp\u003eLa refrigeración activa causa numerosos problemas que en realidad generan más \"ruido\" a largo plazo. La refrigeración activa en cabezales amplificadores usa celdas Peltier, que enfrían la electrónica para un rendimiento ligeramente mejor, pero generan un calor considerable en el lado opuesto de la celda. El calor generado causa deriva térmica que hace casi imposible mantener la conexión durante trabajos de un solo canal. Esta es LA FUENTE MÁS COMÚN de lo que los usuarios perciben como \"deriva del manipulador\". Como empresa que fabrica micromanipuladores, somos muy sensibles al rendimiento del sistema dentro de un equipo completo de electrofisiología.\u003c\/p\u003e\n\u003cp\u003eLa refrigeración activa puede ayudar a obtener una especificación de ruido ligeramente mejor en papel, pero en la práctica las desventajas superan con creces la pequeña ganancia en especificaciones. Uno de los objetivos de desarrollo del cabezal dPatch fue lograr un rendimiento de ruido comparable a temperatura ambiente, sin necesidad de un cabezal refrigerado. En los dos modos de retroalimentación resistiva, el amplificador dPatch es incluso más silencioso que cualquiera de los sistemas competidores. Además, la vida útil limitada de los elementos Peltier genera preocupaciones de fiabilidad que consideramos inaceptables.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eSISTEMA DE ADQUISICIÓN DE DATOS INTEGRADO SIGNIFICA QUE NO SE REQUIERE INTERFAZ DE COMPUTADORA DE TERCEROS\u003c\/h2\u003e\n\u003cp\u003eUsando un diseño sin multiplexor, el dPatch ofrece 8 canales de entrada analógica totalmente diferenciales, 4 canales de salida analógica y 16 salidas digitales (TTL). Todos los canales de E\/S se muestrean continuamente (200 kHz para entradas analógicas, 250 kHz para salidas analógicas y digitales) y están disponibles a través de la interfaz de usuario.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eSOFTWARE SUTTERPATCH\u003c\/h2\u003e\n\u003cp\u003eEl sistema amplificador dPatch, en combinación con el software SutterPatch, ha sido diseñado para capturar y almacenar automáticamente todos los ajustes del amplificador, la información de estímulos y los parámetros externos del experimento, y asociarlos en el tiempo con las trazas de datos en bruto. Esto incluye todos los ajustes del amplificador y de adquisición, así como el tiempo y progreso del experimento. El control informático totalmente integrado de las etapas del amplificador significa que el software de adquisición está al tanto del estado interno del amplificador y digitalizador en todo momento y puede rastrear cualquier cambio que ocurra. Esto es independiente de si un cambio se activa automáticamente o es iniciado por el usuario.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan style=\"color: red;\"\u003e●NUEVA FUNCIÓN● \u003c\/span\u003eDYNAMIC CLAMP\u003c\/h2\u003e\n\u003cp\u003eLa arquitectura digital patentada del sistema amplificador dPatch proporciona una plataforma ideal para el dynamic clamp. El dPatch está impulsado por un sistema en chip que ofrece procesamiento paralelo a través de un Field Programmable Gate Array (FPGA) y dos procesadores ARM de alta velocidad. Varios modelos sofisticados de dynamic clamp están implementados dentro de esta arquitectura. En cada modelo, la actualización de los valores de corriente aplicados ocurre sin comunicación entre el dPatch y una computadora. Dependiendo de la complejidad del modelo, se pueden alcanzar tasas de actualización de hasta 500 kHz. \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eSEGUIMIENTO DE OTROS DATOS EXTERNOS\u003c\/h2\u003e\n\u003cp\u003eAdemás de los cambios de estado en el hardware conectado que se rastrean automáticamente, el investigador puede activar manualmente etiquetas para documentar eventos como la aplicación de estímulos usando instrumentos no conectados al amplificador. Se puede registrar y almacenar información sobre parámetros ambientales y una especificación más detallada de las propiedades de la muestra junto con los datos en bruto. Se admiten más de 650 atributos de metadatos. Ejemplos incluyen: especie animal, genotipo, fecha\/hora en que se preparó una muestra celular, soluciones de grabación, resistencia de la pipeta, propiedades del hardware e información detallada sobre los estímulos aplicados.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eVISUALIZACIÓN Y ANÁLISIS DE DATOS\u003c\/h2\u003e\n\u003cp\u003eEl software SutterPatch ha sido diseñado para simplificar la navegación y el análisis de conjuntos de datos complejos. La ventana de alcance soporta múltiples modos de vista tanto en dos dimensiones como en una innovadora visualización tridimensional. La vista 3D es especialmente útil durante el desarrollo de ensayos. Construido sobre la última versión de la probada plataforma Igor Pro, SutterPatch combina la funcionalidad nativa de Igor Pro con una gran cantidad de características adaptadas a aplicaciones de electrofisiología. Tanto el principiante como el usuario experimentado de programas de patch clamp se sentirán cómodos usando el software SutterPatch.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eLos módulos de aplicación proporcionan funcionalidad específica para aplicaciones particulares.\u003cbr\u003e\u003cbr\u003e\u003cem\u003eActualmente disponible:\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMódulo de detección de eventos: Un algoritmo de deconvolución que sobresale en detectar eventos sinápticos miniatura incluso en un fondo ruidoso.\u003c\/li\u003e\n\u003cli\u003eMódulo de análisis de potencial de acción: Gráfico de plano de fase, estadísticas de tiempo y forma de onda.\u003c\/li\u003e\n\u003cli\u003eMódulo de cámara: Una forma fácil de documentar la identidad y condición de la célula registrada.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eUN CABALLO DE BATALLA DE LABORATORIO\u003c\/h2\u003e\n\u003cp\u003eAunque el sistema dPatch está listo para investigación de vanguardia, su conjunto de características lo hace inmediatamente valioso en cualquier laboratorio.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTres rangos de retroalimentación del cabezal para grabaciones óptimas de célula completa y de un solo canal\u003c\/li\u003e\n\u003cli\u003eCompensación automatizada de la capacitancia del electrodo y de la célula completa\u003c\/li\u003e\n\u003cli\u003eCompensación de resistencia en serie\u003c\/li\u003e\n\u003cli\u003eCableado simple, configuración rápida y fácil\u003c\/li\u003e\n\u003cli\u003eAlto rango dinámico del digitalizador que elimina la necesidad de etapas de ganancia variable\u003c\/li\u003e\n\u003cli\u003eAlta velocidad del digitalizador que elimina preocupaciones sobre la tasa de muestreo\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\n\u003cbr\u003eAPLICACIONES COMUNES:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli type=\"square\"\u003eGrabaciones de un solo canal\u003c\/li\u003e\n\u003cli type=\"square\"\u003eInvestigación auditiva y otras señales que cambian rápidamente\u003c\/li\u003e\n\u003cli type=\"square\"\u003eGrabaciones en cortes de tejido\u003c\/li\u003e\n\u003cli type=\"square\"\u003eExperimentos con células cultivadas\u003c\/li\u003e\n\u003cli type=\"square\"\u003eEstudios de líneas celulares de células adherentes o dispersas\u003c\/li\u003e\n\u003cli type=\"square\"\u003eOptogenética\u003c\/li\u003e\n\u003cli type=\"square\"\u003eInvestigación de nanoporo y nanogap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eCARACTERÍSTICAS\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSoporte técnico gratuito\u003c\/li\u003e\n\u003cli\u003eSistema integrado de amplificador patch clamp de uno o dos cabezales y adquisición de datos que asegura una configuración rápida y sencilla\u003c\/li\u003e\n\u003cli\u003eOptimizado para grabaciones de patch clamp de un solo canal y de célula completa en cortes de tejido, células adherentes o disociadas\u003c\/li\u003e\n\u003cli\u003eControl completo por computadora que proporciona compensación automatizada de la capacitancia del electrodo y de la célula completa\u003c\/li\u003e\n\u003cli\u003eVoltaje clamp, current clamp FastFollower™ y capacidad de dynamic clamp totalmente integrada para caracterización completa de la actividad eléctrica celular\u003c\/li\u003e\n\u003cli\u003eReducción de frecuencia de línea en SutterPatch\u003c\/li\u003e\n\u003cli\u003eAmplificador lock-in por software en SutterPatch para mediciones de capacitancia de alta resolución\u003c\/li\u003e\n\u003cli\u003eAncho de banda alto que permite la caracterización de las señales más rápidas\u003c\/li\u003e\n\u003cli\u003eTres rangos de retroalimentación del cabezal para grabaciones de patch clamp de un solo canal y de célula completa\u003c\/li\u003e\n\u003cli\u003eCircuitería de compensación digital integral que proporciona la máxima precisión y fidelidad de la señal\u003c\/li\u003e\n\u003cli\u003eEl software SutterPatch® incluido ofrece gestión de datos versátil, navegación intuitiva y análisis de datos simplificado.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eAccesorios\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePunto de Tierra\u003c\/strong\u003e\u003cbr\u003eEl Punto de Tierra (#505673) proporciona conexiones confiables y de baja resistencia para una configuración de tierra en estrella, el método comprobado para evitar bucles de tierra en cualquier configuración de electrofisiología. Acepta 9 conectores banana + 8 cables pelados de hasta calibre 10 o conectores banana. La base se monta directamente en mesas de aire imperiales o métricas con los tornillos ¼-20 y M6 incluidos. Fabricado en latón macizo mecanizado con conectores banana\/abrazadera chapados.\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.sutter.com\/productLG\/gp-17_lg.jpg\" target=\"_blank\"\u003e\u003cimg align=\"center\" width=\"300\" alt=\"gp-17\" src=\"https:\/\/www.sutter.com\/productSM\/gp-17_sm.jpg\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cbr\u003e\u003cstrong\u003ePanel de expansión dPatch\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.sutter.com\/productLG\/dpa_expansion_3-4_lg.jpg\" target=\"_blank\"\u003e\u003cimg border=\"0\" align=\"center\" width=\"500\" alt=\"Expansión dPatch\" src=\"https:\/\/www.sutter.com\/productSM\/dpa_expansion_3-4_sm.jpg\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:resources --\u003e\n\u003ch2\u003eManual de usuario\u003c\/h2\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.sutter.com\/manuals\/dPatch_SutterPatch_OpMan.pdf\" title=\"\" target=\"_blank\"\u003eManual de operación dPatch \u0026amp; SutterPatch\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eINFORMACIÓN DEL PRODUCTO\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.sutter.com\/PDFs\/Comparison_aX.pdf\"\u003eComparación con la marca aX\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.sutter.com\/Flyers\/DynamicClamp_flyer.pdf\"\u003eFolleto Dynamic Clamp\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.sutter.com\/Flyers\/DPA_flyer.pdf\"\u003eFolleto de ventas dPatch (versión en inglés)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.sutter.com\/Flyers\/SutterPatch_flyer.pdf\"\u003eFolleto de ventas SutterPatch®\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.sutter.com\/PDFs\/Comparison_Amplifier_Systems.pdf\"\u003eComparación de sistemas amplificadores Sutter\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003ePUBLICACIONES CIENTÍFICAS\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.sutter.com\/PDFs\/IPA_dPA_SutterPatch_Publications.pdf\"\u003eExperimentos de interés que involucran sistemas amplificadores Sutter Instrument y software SutterPatch®\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.sutter.com\/PDFs\/Patch_Clamp_Technology_TwentyFirst_Century.pdf\" target=\"_blank\"\u003eCapítulo del libro: Tecnología de Patch Clamp en el siglo veintiuno\u003c\/a\u003e\u003cbr\u003eEn: \u003ca rel=\"noopener\" href=\"https:\/\/doi.org\/10.1007\/978-1-0716-0818-0_2\" target=\"_blank\"\u003eDallas M., Bell D. (eds) Patch Clamp Electrophysiology. Métodos en Biología Molecular, vol 2188. Humana, Nueva York, NY\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eVIDEOS\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/youtu.be\/T2fKGV-eQl8\"\u003eWEBINAR: Clamp Dinámico y Análisis Cruzado de Experimentos\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/yQO33mOaO38\" target=\"_blank\"\u003eVideo Informativo de SutterPatch\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/fTAOWTVw8mc\"\u003eRecorrido por SutterPatch: #1 Introducción\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/OaZ1mCtyb3I\"\u003eRecorrido por SutterPatch: #2 Control del Amplificador\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/IIzmJVZlL_E\"\u003eRecorrido por SutterPatch: #3 Rutinas\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/HVMup1iDVCI\"\u003eRecorrido por SutterPatch: #4 Navegador de Datos y Metadatos\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/hpu_UJmJ3nM\"\u003eRecorrido por SutterPatch: #5 Módulos de Aplicación\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003ePreguntas frecuentes\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: ¿Cómo se compara el dPatch® con otros amplificadores en el mercado?\u003c\/strong\u003e\u003cbr\u003eA: El dPatch utiliza una arquitectura digital de última generación. Al convertir la señal de analógica a digital cerca del cabezal, preservamos la integridad de la señal tanto como es posible. Casi todas las especificaciones de ruido del dPatch superan a las de todos los demás amplificadores en el mercado. Además, el dPatch constituye un sistema completo de patch clamp, todo el hardware y software de adquisición de datos están incluidos, y no se requiere hardware externo para el clamp dinámico. \u003ca href=\"https:\/\/www.sutter.com\/PDFs\/Comparison_aX.pdf\"\u003e(vea nuestra hoja de comparación)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: ¿Por qué el dPatch no tiene refrigeración activa?\u003c\/strong\u003e\u003cbr\u003eA: La refrigeración activa causa numerosos problemas que en realidad generan más \"ruido\" a largo plazo. El calor generado por las celdas Peltier provoca deriva térmica en los manipuladores, haciendo casi imposible mantener el parche mientras se trabaja con un solo canal. Como empresa que fabrica micromanipuladores, somos muy sensibles al rendimiento del sistema dentro de un equipo completo de electrofisiología. La refrigeración activa puede ayudar a obtener una especificación de ruido ligeramente mejor en papel, pero en el mundo real las desventajas superan con creces la pequeña ganancia en especificaciones (Vea la Hoja de Comparación). Además, la vida útil limitada de los elementos Peltier genera preocupaciones de fiabilidad que consideramos inaceptables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: ¿Necesito comprar un digitalizador o software con el dPatch?\u003c\/strong\u003e\u003cbr\u003eA: No, porque el dPatch es inherentemente un diseño digital, no es necesario un digitalizador adicional. El software SutterPatch® y una licencia para IgorPro están incluidos con cada sistema dPatch. El dPatch incluye todo lo que necesita para comenzar a realizar experimentos.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: ¿Puedo adaptar un segundo cabezal a mi sistema dPatch de un solo cabezal más adelante?\u003c\/strong\u003e\u003cbr\u003eA: Sí, las unidades de cabezal\/preamplificador dPatch son intercambiables y autónomas. Toda la información de calibración y ajuste se almacena directamente en la unidad de cabezal\/preamplificador y se lee durante el inicio. Esto facilita añadir un segundo cabezal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: ¿Los cabezales encajan en mi micromanipulador existente?\u003c\/strong\u003e\u003cbr\u003eA: Todos los cabezales Sutter Instrument vienen con un ajuste estándar de cola de milano. Este ajuste fue introducido conjuntamente por Sutter Instrument y Axon Instruments hace casi 30 años y desde entonces ha sido adoptado por la mayoría de los fabricantes de amplificadores de patch clamp y micromanipuladores. Esto hace que los cabezales Sutter sean un reemplazo directo en un equipo existente, en la mayoría de los casos sin siquiera requerir ajustes.\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:specifications --\u003e\n\u003cp\u003eEl amplificador integrado digital dPatch es un sistema controlado por computadora con una o dos cabezas optimizado para aplicaciones de grabación tanto de un solo canal como de célula completa.\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.sutter.com\/productLG\/dpa_back_lg.jpg\" target=\"_blank\"\u003e\u003cimg align=\"center\" width=\"645\" alt=\"Parte trasera de dPatch\" src=\"https:\/\/www.sutter.com\/productSM\/dpa_back_sm.jpg\"\u003e\u003c\/a\u003e\u003cbr\u003e\u003cem\u003epanel trasero de dPatch. (Haga clic para ver más grande)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cem\u003eAmplificador\u003c\/em\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLa arquitectura de hardware permite que toda la conversión de datos se realice cerca de la preparación, lejos de fuentes conocidas de ruido, como fuentes de alimentación y circuitos digitales de alta velocidad.\u003c\/li\u003e\n\u003cli\u003eModos clamp de voltaje y clamp de corriente verdadero con conmutación inteligente entre modos para evitar artefactos de corriente\u003c\/li\u003e\n\u003cli\u003eTres opciones de elementos de retroalimentación para cabeza para optimizar tanto grabaciones de un solo canal como de célula completa\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\" class=\"product-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003ccenter\u003eRetroalimentación\u003cbr\u003eElemento\u003c\/center\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ccenter\u003eRango\u003c\/center\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ccenter\u003eAnalógico\u003cbr\u003eAncho de banda\u003c\/center\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ccenter\u003eRuido\u003cbr\u003eAncho de banda 10 kHz\u003c\/center\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ccenter\u003ePipeta\u003cbr\u003eCompensación\u003cbr\u003eRango\u003c\/center\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ccenter\u003eEn serie\u003cbr\u003eResistencia\u003cbr\u003eRango\u003c\/center\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ccenter\u003eCélula\u003cbr\u003eCapacitancia\u003cbr\u003eRango\u003c\/center\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ccenter\u003eCapacitivo\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e±20 nA\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e1 MHz\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u0026lt; 0.22 pA\u003csub\u003erms\u003c\/sub\u003e\n\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e20 pF\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003eN\/A*\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003eN\/A*\u003c\/center\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ccenter\u003e500 MΩ\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e±20 nA\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u0026gt; 250 kHz\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u0026lt; 0.7 pA\u003csub\u003erms\u003c\/sub\u003e\n\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e20 pF\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e100 MΩ\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e100 pF\u003c\/center\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ccenter\u003e50 MΩ\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e±200 nA\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u0026gt; 250 kHz\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u0026lt; 2.3 pA\u003csub\u003erms\u003c\/sub\u003e\n\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e20 pF\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e10 MΩ\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e1000 pF\u003c\/center\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003e\u003csup\u003e*\u003c\/sup\u003e El rango de retroalimentación capacitiva está optimizado para grabaciones en modo clamp de voltaje de un solo canal. La compensación de célula completa y el modo clamp de corriente están deshabilitados con este rango.\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRutinas automáticas de compensación para compensación de pipeta, compensación de célula completa y compensación de resistencia en serie\u003c\/li\u003e\n\u003cli\u003ePredicción y corrección de resistencia en serie programables de forma independiente\u003c\/li\u003e\n\u003cli\u003eFiltro Bessel de 8 polos 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 250, 500, 1000 kHz\u003c\/li\u003e\n\u003cli\u003eProcesamiento de señal de la salida del filtro para aumentar la resolución y reducir el tamaño del archivo de datos\u003c\/li\u003e\n\u003cli\u003eResolución superior a 22 bits con filtro configurado a 1 kHz\u003c\/li\u003e\n\u003cli\u003eAlto rango dinámico de los convertidores analógico a digital elimina la necesidad de etapas de ganancia de salida variables\u003c\/li\u003e\n\u003cli\u003ePotencial de mantenimiento ±1000 mV\u003c\/li\u003e\n\u003cli\u003eCompensación de puente en modo clamp de corriente y compensación de capacitancia de la pipeta\u003c\/li\u003e\n\u003cli\u003eSeguimiento lento del potencial de mantenimiento compensa la deriva durante grabaciones en modo clamp de corriente\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cem\u003eAdquisición de datos\u003c\/em\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSistema de adquisición de datos integrado elimina la necesidad de una tarjeta de adquisición de datos externa\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eTasa de muestreo de 5 MHz por cabeza, resolución de 22 bits\u003c\/li\u003e\n\u003cli\u003e8 entradas analógicas auxiliares, 16 bits totalmente diferenciales, ±10 V, cada una muestreada continuamente a 200 kHz\u003c\/li\u003e\n\u003cli\u003e4 salidas analógicas, 16 bits, ±10 V cada una actualizada continuamente a 250 kHz\u003c\/li\u003e\n\u003cli\u003e16 salidas digitales (TTL) cada una funcionando a 250 kHz\u003c\/li\u003e\n\u003cli\u003eDisparador IN \/ Disparador OUT independiente para la sincronización de instrumentación externa\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eConexión única SuperSpeed USB 3.0 controla la adquisición de datos y el amplificador\u003c\/li\u003e\n\u003cli\u003eFormas de onda de comando complejas\u003c\/li\u003e\n\u003cli\u003eLa adquisición de datos puede iniciarse mediante un reloj interno de microsegundos o un disparador externo (TTL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cem\u003eSoftware SutterPatch\u003c\/em\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConstruido sobre la base de Igor Pro 8 (WaveMetrics, Inc.)\u003c\/li\u003e\n\u003cli\u003eParadigmas y Rutinas proporcionan control experimental completo\u003c\/li\u003e\n\u003cli\u003eEditor de formas de onda para la creación fácil incluso de los patrones de estímulo más complejos o plantillas definidas por el usuario\u003c\/li\u003e\n\u003cli\u003eAssociated Metadata almacena toda la información relevante sobre su experimento\u003c\/li\u003e\n\u003cli\u003eRutinas completas de análisis de datos y gráficos de calidad para publicación\u003c\/li\u003e\n\u003cli\u003eReducción rápida en línea de la frecuencia de la red eléctrica\u003c\/li\u003e\n\u003cli\u003eFunciona en Windows 10 o posterior (64 bits), o Macintosh OS X 10.11 (El Capitan) o versiones más recientes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp align=\"center\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.sutter.com\/productLG\/sutterpatch.jpg\" target=\"_blank\"\u003e\u003cimg align=\"center\" width=\"645\" alt=\"Sutterpatch\" src=\"https:\/\/www.sutter.com\/productLG\/sutterpatch.jpg\"\u003e\u003c\/a\u003e\u003cbr\u003e\u003cem\u003eCaptura de pantalla del software SutterPatch\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eESPECIFICACIONES TÉCNICAS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensiones\u003c\/strong\u003e\u003cbr\u003e\u003cem\u003edPatch:\u003c\/em\u003e 19 in x 11 in x 3.5 in | 48.2 cm x 28 cm x 9 cm\u003cbr\u003e\u003cbr\u003e\u003cem\u003edPatch Preamplifier:\u003c\/em\u003e 7.6 in x 3.5 in x 1.2 in | 19.5 cm x 9 cm x 3 cm\u003cbr\u003e\u003cbr\u003e\u003cem\u003edPatch Headstage:\u003c\/em\u003e 3.7 in x 1.1 in x 0.66 in | 9.5 cm x 2.9 cm x 1.7 cm\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003ePeso\u003c\/strong\u003e\u003cbr\u003e\u003cem\u003edPatch:\u003c\/em\u003e 15 lbs | 6.8 kg\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eEléctrico\u003c\/strong\u003e\u003cbr\u003e110\/240 Voltios\u003cbr\u003eLínea eléctrica de 50\/60 Hertz\u003cbr\u003e\u003cbr\u003e*Patente No. US 10,393,727 B2\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCumple con RoHS\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.sutter.com\/PDFs\/CE\/CE_EU_DoC_DPATCH.pdf\" target=\"_blank\"\u003eCertificado CE DPATCH\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg height=\"53\" width=\"75\" alt=\"Logotipo CE\" src=\"https:\/\/www.sutter.com\/images\/structure\/ce-marking-logo.png\"\u003e   \u003cimg height=\"50\" width=\"50\" alt=\"UKCA\" src=\"https:\/\/www.sutter.com\/images\/structure\/UKCA_74.png\"\u003e   \u003cimg height=\"57\" width=\"65\" alt=\"Chiana CE\" src=\"https:\/\/www.sutter.com\/images\/structure\/China_CE_97.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eREQUISITOS DEL SISTEMA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eConfiguración mínima:\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWindows 10 (64 bits), o MacOS: 10.11, El Capitan o posterior\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProcesador: i5 de doble núcleo\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eMemoria: 8 GB\u003c\/li\u003e\n\u003cli\u003eUnidad de estado sólido (SSD): 500 GB o más\u003c\/li\u003e\n\u003cli\u003eResolución de pantalla: 1024 x 768 (XGA)\u003c\/li\u003e\n\u003cli\u003e1 puerto USB 3.0 SuperSpeed disponible (en la placa principal, no en una tarjeta PCIx o similar)\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003cem\u003eConfiguración recomendada para anchos de banda de \u0026gt;50 kHz:\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWindows 10 (64 bits), o MacOS: 10.11, El Capitan o posterior\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProcesador: i5 de doble núcleo\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eMemoria: 16 GB\u003c\/li\u003e\n\u003cli\u003eUnidad de estado sólido (SSD): 500 GB o más\u003c\/li\u003e\n\u003cli\u003eResolución de pantalla 1920 x 1080 (Full HD)\u003c\/li\u003e\n\u003cli\u003e1 puerto USB 3.0 SuperSpeed disponible (en la placa principal, no en una tarjeta PCIx o similar)\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSistema de gestión y análisis de adquisición de datos SUTTERPATCH®: Incluido con todos los sistemas amplificadores Sutter Instrument\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003csup\u003e1\u003c\/sup\u003e No se admiten sistemas operativos instalados dentro de plataformas de software de virtualización como VMware y Parallels.\u003cbr\u003e\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e En este momento, WaveMetrics no admite completamente Igor Pro en computadoras Mac basadas en la arquitectura Apple Silicon M1. Consulte \u003ca rel=\"noopener\" href=\"https:\/\/www.wavemetrics.com\/news\/igor-and-apple-arm-processors\" target=\"_blank\"\u003ehttps:\/\/www.wavemetrics.com\/news\/igor-and-apple-arm-processors\u003c\/a\u003e para detalles técnicos. Experimentos preliminares indican que el software SutterPatch funciona en estas computadoras, tanto con Igor Pro 8 como 9, y con cada uno de los sistemas amplificadores Sutter conectados. Sin embargo, como con cada nueva tecnología, no podemos excluir completamente incompatibilidades.\u003cbr\u003e\u003cbr\u003e\u003csup\u003e3\u003c\/sup\u003e Los puertos USB 3.0 son compatibles con las especificaciones USB 2.0 High Speed.\u003cbr\u003eNo se admiten los puertos USB 2.0 ‘full-speed’ más lentos, que a veces se encuentran en PCs Windows más antiguos o tarjetas de expansión USB.\u003cbr\u003e\u003cbr\u003ePara verificar USB 2.0 High Speed o USB 3.0 en una computadora PC con Windows, busque en el Panel de control \u0026gt; Administrador de dispositivos \u0026gt; sección Controladores de bus serie universal los controladores de host “Mejorados”. Como esto no proporciona información de mapeo a los puertos físicos de la computadora, y puede haber una mezcla de versiones de puertos USB, debe verificar el rendimiento operativo de cada puerto USB para USB 2.0\/3.0 High Speed. Como indicador visual, los puertos USB 3.0 suelen estar codificados en color azul.\u003cbr\u003e\u003cbr\u003eNo se admiten concentradores USB. No se recomiendan las tarjetas de expansión USB, incluso si cumplen formalmente con las especificaciones High Speed o Super Speed. A menudo están configuradas arquitectónicamente como concentradores USB y pueden provocar errores intermitentes de transferencia que son difíciles de solucionar.\u003cbr\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"53\" width=\"75\" alt=\"Logotipo CE\" src=\"https:\/\/www.sutter.com\/images\/structure\/ce-marking-logo.png\"\u003e\u003cbr\u003e\u003cimg height=\"59\" width=\"72\" alt=\"RoHS\" src=\"https:\/\/www.sutter.com\/images\/structure\/rohs.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Sistema dPatch con un cabezal y preamplificador","offer_id":42267582464090,"sku":"SU-DPATCH","price":29630.01,"currency_code":"USD","in_stock":true},{"title":"Sistema dPatch con dos cabezales y preamplificador","offer_id":42267582496858,"sku":"SU-DPATCH-2","price":35829.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/double_dpa_lg_c7fa529a-e687-4700-bbc0-31dea413bb84.jpg?v=1766414927"},{"product_id":"var-su-ipa-ipa-system","title":"Sistema IPA","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eOpciones\u003c\/h2\u003e\r\n\u003ctable class=\"product-table\" style=\"height: 54px; width: 100%;\" width=\"100%\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"height: 18px;\"\u003e\r\n\u003ctd style=\"text-align: center; height: 18px; width: 15.2358%;\"\u003e\u003cstrong\u003eCódigo de pedido\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; height: 18px; width: 36.5175%;\"\u003e\u003cstrong\u003eDescripción\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 48.2467%;\"\u003e\u003cstrong\u003eDetalles\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 18px;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 15.2358%;\"\u003eSU-IPA\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 36.5175%;\"\u003eSistema IPA con cabezal\u003c\/td\u003e\r\n\u003ctd style=\"width: 48.2467%;\"\u003eIncluye: sistema IPA con cabezal, soporte para pipeta 505671, célula modelo, cable breakout “octopus”, hardware para montaje en rack; suite de software SutterPatch® con licencia Igor Pro\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 18px;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 15.2358%;\"\u003eSU-IPA2\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 36.5175%;\"\u003eSistema IPA doble con dos cabezales\u003c\/td\u003e\r\n\u003ctd style=\"width: 48.2467%;\"\u003eIncluye: sistema IPA doble con dos cabezales, dos soportes para pipetas 505671, célula modelo, cable breakout “octopus”, hardware para montaje en rack; suite de software SutterPatch® con licencia Igor Pro.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003ch2\u003eEntradas y Salidas Externas\u003c\/h2\u003e\r\n\u003cp\u003eSe pueden registrar señales externas, como parámetros ambientales o información de estímulos, usando 4 canales de entrada analógica auxiliares. Los sistemas IPA también soportan el control de hardware periférico, como conmutadores de longitud de onda o de soluciones, con 2 canales de salida analógica y 8 canales digitales (TTL). Como alternativa al cable estándar de breakout, un Panel Patch opcional proporciona una forma ordenada de conectar señales auxiliares en la parte frontal de su rack.\u003c\/p\u003e\r\n\u003ch2\u003eSoftware SutterPatch\u003c\/h2\u003e\r\n\u003cp\u003eEl sistema IPA, en combinación con el software SutterPatch, ha sido diseñado para capturar y almacenar automáticamente todos los ajustes del amplificador, información de estímulos y parámetros externos del experimento, y asociarlos en el tiempo con las trazas de datos en bruto. Esto incluye todos los ajustes del amplificador y de adquisición, así como el tiempo y progreso del experimento. El control informático totalmente integrado de las etapas del amplificador significa que el software de adquisición está al tanto del estado interno del amplificador y digitalizador en todo momento y puede rastrear cualquier cambio que ocurra. Esto es independiente de si un cambio se activa automáticamente o es iniciado por el usuario.\u003c\/p\u003e\r\n\u003ch2\u003eSeguimiento de Otros Datos Externos\u003c\/h2\u003e\r\n\u003cp\u003eAdemás de los cambios de estado en el hardware conectado que se rastrean automáticamente, el experimentador puede activar manualmente etiquetas para documentar eventos como la aplicación de estímulos en instrumentos no conectados al sistema IPA.\u003cbr\u003e\u003cbr\u003eSe puede registrar y almacenar información sobre parámetros ambientales y una especificación más detallada de las propiedades de la muestra junto con los datos en bruto. Se soportan más de 600 atributos de metadatos en total. Ejemplos incluyen: especie animal, cepa, genotipo, fecha\/hora en que se preparó una muestra celular, soluciones de grabación, resistencia de la pipeta, propiedades del hardware e información detallada sobre los estímulos aplicados.\u003c\/p\u003e\r\n\u003ch2\u003eVisualización y Análisis de Datos\u003c\/h2\u003e\r\n\u003cp\u003eEl software SutterPatch ha sido diseñado para simplificar la navegación y el análisis de conjuntos de datos complejos. La ventana de alcance soporta múltiples modos de vista tanto en dos dimensiones como en una innovadora visualización tridimensional. La vista 3D es particularmente útil durante el desarrollo de ensayos. Construido sobre la última versión de la probada plataforma Igor Pro, el programa SutterPatch combina la funcionalidad nativa de Igor Pro con una gran cantidad de características adaptadas a aplicaciones de electrofisiología. Tanto el usuario novato como el experimentado en programas de patch clamp se sentirán cómodos usando el software SutterPatch.\u003c\/p\u003e\r\n\u003cp\u003eLos módulos de aplicación proporcionan funcionalidad enfocada para aplicaciones particulares.\u003c\/p\u003e\r\n\u003cul\u003eActualmente disponible:\r\n\u003cli\u003e\n\u003cem\u003eMódulo de detección de eventos:\u003c\/em\u003e Un algoritmo de deconvolución que destaca en la detección de eventos sinápticos miniatura incluso en un fondo ruidoso\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cem\u003eMódulo de análisis de potencial de acción:\u003c\/em\u003e Gráfica de plano de fase, estadísticas de tiempo y forma de onda\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cem\u003eMódulo de cámara:\u003c\/em\u003e Una forma fácil de documentar la identidad y condición de la célula registrada\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eLos amplificadores integrados de patch clamp IPA y Double IPA son amplificadores controlados por computadora de uno o dos cabezales optimizados para aplicaciones de grabación de célula completa.\u003c\/p\u003e\r\n\u003ch2 style=\"text-align: left;\" align=\"center\"\u003eAPLICACIONES COMUNES\u003c\/h2\u003e\r\n\u003cdiv\u003e\r\n\u003cul\u003e\r\n\u003cli type=\"square\"\u003eGrabaciones en cortes de tejido\u003c\/li\u003e\r\n\u003cli type=\"square\"\u003eExperimentos con células cultivadas\u003c\/li\u003e\r\n\u003cli type=\"square\"\u003eEstudios de líneas celulares de células adheridas o dispersas\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003c\/div\u003e\r\n\u003cdiv\u003e\r\n\u003cul\u003e\r\n\u003cli type=\"square\"\u003e\nPatch clamp \u003cem\u003ein vivo\u003c\/em\u003e\u003c\/li\u003e\r\n\u003cli type=\"square\"\u003eEstudios de redes\u003c\/li\u003e\r\n\u003cli type=\"square\"\u003eOptogenética\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003c\/div\u003e\r\n\u003cdiv\u003e \u003c\/div\u003e\r\n\u003ch2\u003eCARACTERÍSTICAS\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\n\u003cstrong\u003eNUEVO:\u003c\/strong\u003e La combinación de dos dispositivos IPA o Double IPA permite hasta cuatro canales de cabeza para hasta 16 señales\u003c\/li\u003e\r\n\u003cli\u003eSistema integrado de amplificador patch clamp y adquisición de datos que asegura una configuración rápida y sencilla\u003c\/li\u003e\r\n\u003cli\u003eOptimizado para grabaciones de patch clamp de célula completa en cortes de tejido, células adheridas o disociadas\u003c\/li\u003e\r\n\u003cli\u003eControl completo por computadora que proporciona compensación automatizada de la capacitancia del electrodo y de la célula completa\u003c\/li\u003e\r\n\u003cli\u003eCapacidad de pinza de voltaje y corriente para caracterización completa de la actividad eléctrica de las células\u003c\/li\u003e\r\n\u003cli\u003eEl software incluido de SutterPatch destaca en gestión integral de datos, navegación intuitiva y análisis de datos simplificado\u003c\/li\u003e\r\n\u003cli\u003eReducción de frecuencia de línea en SutterPatch\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2 style=\"text-align: left;\" align=\"center\"\u003eACCESORIOS\u003c\/h2\u003e\r\n\u003cp\u003e\u003cstrong\u003ePanel de Parche IPA opcional\u003c\/strong\u003e\u003cbr\u003eLos amplificadores IPA y Double IPA vienen de serie con un cable divisor \"pulpo\" para entradas y salidas auxiliares, y salidas digitales. El Panel de Parche IPA opcional, mecanizado a partir de un bloque de aluminio de ½\" de espesor como la placa frontal del IPA, lleva las conexiones auxiliares de E\/S al frente del rack en un panel de montaje en rack 2U ordenado con conectores BNC. El Panel de Parche IPA incluye un cable conector de 2.5 pies (76 cm) y reemplaza el cable estándar que se envía con el sistema IPA.\u003cbr\u003e\u003ca href=\"https:\/\/www.sutter.com\/productLG\/ipa_patch_lg.jpg\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/www.sutter.com\/productSM\/ipa_patch_sm.jpg\" alt=\"Parche IPA\" width=\"645\" align=\"center\"\u003e\u003c\/a\u003e\u003cbr\u003e\u003cstrong\u003ePunto de tierra\u003c\/strong\u003e\u003cbr\u003eEl Ground Point (505673) proporciona conexiones confiables y de baja resistencia para conexiones de tierra en estrella, el método comprobado para evitar bucles de tierra en cualquier configuración de electrofisiología. Acepta 9 conectores banana + 8 cables pelados de hasta calibre 10 o conectores banana. La base se monta directamente en mesas de aire estándar o métricas con los tornillos ¼-20 y M6 incluidos. Fabricado en latón macizo mecanizado con conectores banana\/abrazadera chapados.\u003c\/p\u003e\r\n\u003cp align=\"center\"\u003e\u003ca href=\"https:\/\/www.sutter.com\/productLG\/gp-17_lg.jpg\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/www.sutter.com\/productSM\/gp-17_sm.jpg\" alt=\"GP 17\" width=\"300\" align=\"center\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003ch2\u003eMANUALES DE USUARIO\u003c\/h2\u003e\r\n\u003cp\u003e\u003ca href=\"https:\/\/www.sutter.com\/manuals\/IPA_SutterPatch_QSGuide.pdf\" target=\"new\"\u003eGuía rápida de inicio IPA \u0026amp; SutterPatch\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.sutter.com\/manuals\/IPA_SutterPatch_OpMan.pdf\" target=\"new\"\u003eManual de operación IPA \u0026amp; SutterPatch\u003c\/a\u003e\u003c\/p\u003e\r\n\u003ch2\u003eINFORMACIÓN DEL PRODUCTO\u003c\/h2\u003e\r\n\u003cp\u003e\u003cstrong\u003eFolleto de ventas IPA \/ DOUBLE IPA:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.sutter.com\/Flyers\/IPA_flyer.pdf\" target=\"new\"\u003eInglés\u003c\/a\u003e \/ \u003ca href=\"https:\/\/www.sutter.com\/Flyers\/IPA_flyer_china.pdf\" target=\"new\"\u003eChino\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.sutter.com\/Flyers\/SutterPatch_flyer.pdf\" target=\"new\"\u003eFolleto de ventas de SutterPatch\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.sutter.com\/PDFs\/Comparison_Amplifier_Systems.pdf\" target=\"new\"\u003eComparación de sistemas amplificadores Sutter\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/yQO33mOaO38\" target=\"_blank\" rel=\"noopener\"\u003eVideo Informativo de SutterPatch\u003c\/a\u003e\u003c\/p\u003e\r\n\u003ch2\u003ePUBLICACIONES CIENTÍFICAS\u003c\/h2\u003e\r\n\u003cp\u003e\u003ca href=\"https:\/\/www.sutter.com\/PDFs\/IPA_dPA_SutterPatch_Publications.pdf\" target=\"new\"\u003eExperimentos de interés que involucran sistemas amplificadores Sutter Instrument y software SutterPatch®\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.sutter.com\/PDFs\/Patch_Clamp_Technology_TwentyFirst_Century.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCapítulo de libro: Tecnología Patch Clamp en el Siglo Veintiuno\u003c\/a\u003e\u003cbr\u003eEn: \u003ca href=\"https:\/\/doi.org\/10.1007\/978-1-0716-0818-0_2\" target=\"_blank\" rel=\"noopener\"\u003eDallas M., Bell D. (eds) Patch Clamp Electrophysiology. Methods in Molecular Biology, vol 2188. Humana, New York, NY\u003c\/a\u003e\u003c\/p\u003e\r\n\u003ch2\u003eVIDEOS\u003c\/h2\u003e\r\n\u003cp\u003e\u003ca href=\"https:\/\/youtu.be\/yQO33mOaO38\" target=\"_blank\" rel=\"noopener\"\u003eVideo Informativo de SutterPatch\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/fTAOWTVw8mc\" target=\"new\"\u003eRecorrido por SutterPatch: #1 Introducción\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/OaZ1mCtyb3I\" target=\"new\"\u003eRecorrido por SutterPatch: #2 Control del Amplificador\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/IIzmJVZlL_E\" target=\"new\"\u003eRecorrido por SutterPatch: #3 Rutinas\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/HVMup1iDVCI\" target=\"new\"\u003eRecorrido por SutterPatch: #4 Navegador de Datos y Metadatos\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/hpu_UJmJ3nM\" target=\"new\"\u003eRecorrido por SutterPatch: #5 Módulos de Aplicación\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/T2fKGV-eQl8\" target=\"new\"\u003eWEBINAR: Clamp Dinámico y Análisis Cruzado de Experimentos\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/v.youku.com\/v_show\/id_XNDY0Mzk5OTUyNA\" target=\"new\"\u003eWEBINAR: Clamp Dinámico y Análisis Cruzado de Experimentos (Youku)\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ch2\u003eAmplificador\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eModos de clamp de voltaje y clamp de corriente verdadero con conmutación inteligente entre modos para evitar artefactos de corriente\u003c\/li\u003e\r\n\u003cli\u003eRuido de circuito abierto (RMS) de 1.4 pA en un ancho de banda de 0.1-10 kHz\u003c\/li\u003e\r\n\u003cli\u003eResistencia de retroalimentación del cabezal de 500 MΩ que proporciona un rango máximo de ±20 nA\u003c\/li\u003e\r\n\u003cli\u003eCompensación rápida de capacitancia de pipeta y compensación de toda la célula\u003c\/li\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eCompensación de capacitancia de pipeta hasta 25 pF\u003c\/li\u003e\r\n\u003cli\u003eCompensación de toda la célula: C\u003csub\u003em\u003c\/sub\u003e de 1 a 100 pF ; R\u003csub\u003es\u003c\/sub\u003e de 1 a 100 MΩ\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cli\u003eRutinas automáticas de compensación integradas\u003c\/li\u003e\r\n\u003cli\u003ePredicción y corrección de resistencia en serie (0-100 MΩ)\u003c\/li\u003e\r\n\u003cli\u003eFiltro pasa bajos Bessel de cuatro polos (frecuencia de corte = 0.5 – 20 kHz)\u003c\/li\u003e\r\n\u003cli\u003eGanancia de salida: 0.5-25 mV\/pA (clamp de voltaje); 10-500 mV\/mV (clamp de corriente)\u003c\/li\u003e\r\n\u003cli\u003ePotencial de mantenimiento ±1000 mV\u003c\/li\u003e\r\n\u003cli\u003eCompensación de puente en modo clamp de corriente y neutralización de capacitancia\u003c\/li\u003e\r\n\u003cli\u003eSeguimiento lento del potencial de mantenimiento que compensa la deriva durante grabaciones en modo clamp de corriente\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eAdquisición de datos\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eSistema de adquisición de datos integrado que elimina la necesidad de una tarjeta externa y facilita la configuración\u003c\/li\u003e\r\n\u003cli\u003eConexión USB de alta velocidad única que controla la adquisición de datos y el amplificador\u003c\/li\u003e\r\n\u003cli\u003eHasta 6 u 8 canales de entrada (tasa de muestreo por canal de 0.1 a 50 kHz)\u003c\/li\u003e\r\n\u003cli\u003eTasa de muestreo agregada de hasta 400 kHz\u003c\/li\u003e\r\n\u003cli\u003eModo multiamplificador: se puede conectar una combinación de dos amplificadores IPA o Double IPA, proporcionando hasta 16 canales de entrada\u003c\/li\u003e\r\n\u003cli\u003eFormas de onda de comando complejas\u003c\/li\u003e\r\n\u003cli\u003eEntrada\/salida auxiliar para control de otros instrumentos\u003c\/li\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e4 canales de entrada analógica (±10 V)\u003c\/li\u003e\r\n\u003cli\u003e2 canales de salida analógica (±10 V)\u003c\/li\u003e\r\n\u003cli\u003e8 canales de salida digital (TTL)\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cli\u003eLa adquisición de datos puede iniciarse mediante un reloj interno de microsegundos o un disparador externo (TTL)\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eSoftware SutterPatch®\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eConstruido sobre la base de Igor Pro (WaveMetrics, Inc.)\u003c\/li\u003e\r\n\u003cli\u003eParadigmas y rutinas que proporcionan control experimental completo\u003c\/li\u003e\r\n\u003cli\u003eEditor de formas de onda para la creación fácil de patrones de estímulo incluso complejos o plantillas definidas por el usuario\u003c\/li\u003e\r\n\u003cli\u003eLos metadatos asociados almacenan toda la información relevante sobre su experimento\u003c\/li\u003e\r\n\u003cli\u003eRutinas completas de análisis de datos y gráficos de calidad para publicación\u003c\/li\u003e\r\n\u003cli\u003eFunciona en Windows 10 o posterior (64 bits) o Mac OS X 10.11 (El Capitan) o posterior\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003ca href=\"https:\/\/www.sutter.com\/productLG\/sutterpatch.jpg\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/www.sutter.com\/productLG\/sutterpatch.jpg\" alt=\"Parche Sutter\" width=\"645\" align=\"center\"\u003e\u003c\/a\u003e \u003c\/p\u003e\r\n\u003cp\u003e\u003cem\u003eCaptura de pantalla del software SutterPatch\u003c\/em\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\r\n\u003ch2\u003eESPECIFICACIONES TÉCNICAS\u003c\/h2\u003e\r\n\u003cp\u003e\u003cstrong\u003eDimensiones\u003c\/strong\u003e\u003cbr\u003e\u003cem\u003eIPA®:\u003c\/em\u003e 18.8 in x 11.8 in x 1.8 in | 48 cm x 30 cm x 4.5 cm\u003cbr\u003e\u003cem\u003eDOUBLE IPA®:\u003c\/em\u003e 18.8 in x 11.8 in x 3.5 in | 48 cm x 30 cm x 9 cm\u003cbr\u003e\u003cem\u003eIPA Headstage:\u003c\/em\u003e 4.0 in x 1.4 in x 0.75 in | 10 cm x 3.5 cm x 1.9 cm\u003cbr\u003e\u003cem\u003ePanel de conexiones:\u003c\/em\u003e 18.8 in x 2.0 in x 3.5 in | 48 cm x 5 cm x 9 cm\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003ePeso\u003c\/strong\u003e\u003cbr\u003e\u003cem\u003eIPA:\u003c\/em\u003e 9 lbs | 4 kg\u003cbr\u003e\u003cem\u003eDOUBLE IPA:\u003c\/em\u003e 8.1 lbs | 3.7 kg\u003cbr\u003e\u003cem\u003ePanel de conexiones:\u003c\/em\u003e 3.5 lbs | 1.6 kg\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eEléctrico\u003c\/strong\u003e\u003cbr\u003e110\/240 Voltios\u003cbr\u003eLínea eléctrica de 50\/60 Hertz\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eCumple con RoHS\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.sutter.com\/PDFs\/CE\/CE_EU_DoC_IPA_DOUBLE_IPA.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCertificado CE IPA \u0026amp; DOUBLE IPA\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/www.sutter.com\/images\/structure\/ce-marking-logo.png\" alt=\"CE\" width=\"75\" height=\"53\"\u003e   \u003cimg src=\"https:\/\/www.sutter.com\/images\/structure\/UKCA_74.png\" alt=\"Reino Unido CE\" width=\"50\" height=\"50\"\u003e   \u003cimg src=\"https:\/\/www.sutter.com\/images\/structure\/China_CE_97.png\" alt=\"China CE\" width=\"65\" height=\"57\"\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eREQUISITOS DEL SISTEMA\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cem\u003eConfiguración mínima:\u003c\/em\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eWindows 10 (64 bits), o MacOS: 10.11, El Capitan o posterior\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/li\u003e\r\n\u003cli\u003eProcesador: i5 de doble núcleo\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\r\n\u003cli\u003eMemoria: 3 GB\u003c\/li\u003e\r\n\u003cli\u003eDisco duro: 500 GB o más\u003c\/li\u003e\r\n\u003cli\u003eResolución de pantalla: 1024 x 768 (XGA)\u003c\/li\u003e\r\n\u003cli\u003e1 puerto USB 2.0 High Speed disponible\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cbr\u003e\u003cem\u003eConfiguración recomendada para anchos de banda de \u0026gt;50 kHz:\u003c\/em\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eWindows 10 (64 bits), o MacOS: 10.11, El Capitan o posterior\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/li\u003e\r\n\u003cli\u003eProcesador: i5 de doble núcleo\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\r\n\u003cli\u003eMemoria: 8 GB\u003c\/li\u003e\r\n\u003cli\u003eUnidad de estado sólido (SSD): 500 GB o más\u003c\/li\u003e\r\n\u003cli\u003eResolución de pantalla 1920 x 1080 (Full HD)\u003c\/li\u003e\r\n\u003cli\u003e1 puerto USB 2.0 High Speed disponible\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003eSistema de gestión y análisis de adquisición de datos SUTTERPATCH®: Incluido con todos los sistemas amplificadores Sutter Instrument\u003c\/p\u003e\r\n\u003cp\u003e\u003cem\u003e\u003csup\u003e1\u003c\/sup\u003e Los sistemas operativos instalados dentro de plataformas de software de virtualización como VMware y Parallels no son compatibles.\u003cbr\u003e\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e En este momento, WaveMetrics no soporta completamente Igor Pro en computadoras Mac basadas en la arquitectura Apple Silicon M1. Consulte \u003ca href=\"https:\/\/www.wavemetrics.com\/news\/igor-and-apple-arm-processors\" target=\"_blank\" rel=\"noopener\"\u003ehttps:\/\/www.wavemetrics.com\/news\/igor-and-apple-arm-processors\u003c\/a\u003e para detalles técnicos. Experimentos preliminares indican que el software SutterPatch funciona en estas computadoras, tanto con Igor Pro 8 y 9, y con cada uno de los sistemas amplificadores Sutter conectados. Sin embargo, como con cada nueva tecnología, no podemos excluir completamente incompatibilidades.\u003cbr\u003e\u003cbr\u003e\u003csup\u003e3\u003c\/sup\u003e Los puertos USB 3.0 son compatibles con las especificaciones USB 2.0 High Speed.\u003cbr\u003eLos puertos USB 2.0 ‘full-speed’ más lentos, que a veces se encuentran en PCs Windows más antiguos o tarjetas de expansión USB, no son compatibles.\u003cbr\u003e\u003cbr\u003ePara verificar USB 2.0 High Speed o USB 3.0 en una computadora PC con Windows, busque en el Panel de control \u0026gt; Administrador de dispositivos \u0026gt; sección de controladores de bus serie universal para controladores host “Mejorados”. Como esto no proporciona información de mapeo a los puertos físicos de la computadora, y puede haber una mezcla de versiones de puertos USB, debe verificar el rendimiento operativo de cada puerto USB para USB 2.0\/3.0 High Speed. Como indicador visual, los puertos USB 3.0 suelen estar codificados en color azul.\u003cbr\u003e\u003cbr\u003eLos concentradores USB no son compatibles. Las tarjetas de expansión USB, incluso si cumplen formalmente con las especificaciones High Speed o Super Speed, no se recomiendan. A menudo están configuradas arquitectónicamente como concentradores USB y pueden causar errores intermitentes de transferencia que son difíciles de solucionar.\u003cbr\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Sistema IPA doble con dos cabezales","offer_id":42267583152218,"sku":"SU-IPA2","price":22197.5,"currency_code":"USD","in_stock":true},{"title":"Sistema IPA con cabezal","offer_id":42267583184986,"sku":"SU-IPA","price":17231.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ipa_dipa_lg_1_5bd1743b-856a-41c7-8862-4f1e9e17204b.jpg?v=1766414954"},{"product_id":"iso-80-isolated-differential-amplifier-with-active-probe","title":"Amplificador Diferencial Aislado con Sonda Activa","description":"\u003c!-- section:details --\u003e\n\u003cp\u003e\u003ca href=\"\/es\/blog\/post\/wpi-s-low-noise-amplifiers-outperform-cheap-imitations\"\u003eVea lo que necesita saber antes de comprar un amplificador.\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eExcelente rendimiento de grabación para potenciales de acción nerviosos extracelulares\u003c\/h2\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAlimentado por batería, recargable\u003c\/li\u003e\n\u003cli\u003eFiltrado pasa-altos y pasa-bajos\u003c\/li\u003e\n\u003cli\u003eEtapa remota activa\u003c\/li\u003e\n\u003cli\u003eAmplificación solo de CA\u003c\/li\u003e\n\u003cli\u003eFunción de prueba de impedancia del electrodo\u003c\/li\u003e\n\u003cli\u003eGeneración de corriente para electrodo con selección de polaridad\u003c\/li\u003e\n\u003cli\u003ePosicionamiento de salida variable\u003c\/li\u003e\n\u003cli\u003eLa sonda de reemplazo ISO-80P no necesita enviar el ISO-80 para calibración\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEl kit de inicio incluye 2-CBL102, 2-5469, 2-13388, 3294, 2033, 2034, 2-2035, 2-M3301EH, 5470, EP1.\u003c\/p\u003e\n\u003ch2\u003eBeneficios\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFuente de alimentación de corriente continua ultra silenciosa\u003c\/li\u003e\n\u003cli\u003eBaja susceptibilidad intrínseca a bucles de tierra\u003c\/li\u003e\n\u003cli\u003eAlta relación señal-ruido debido a la etapa remota\u003c\/li\u003e\n\u003cli\u003ePequeña huella\u003c\/li\u003e\n\u003cli\u003eCorriente para estimulación\/marcado histológico\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAmplificación de bio-potenciales usando microelectrodos metálicos\u003c\/li\u003e\n\u003cli\u003ePotenciales de campo en cortes cerebrales\u003c\/li\u003e\n\u003cli\u003eEAG (Electroantennograma)\u003c\/li\u003e\n\u003cli\u003eERG (Electrorretinograma)\u003c\/li\u003e\n\u003cli\u003eMonitoreo de potenciales de acción nerviosos extracelulares\u003c\/li\u003e\n\u003cli\u003eUso para marcado celular, estimulación o limpieza de electrodos\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eIn vivo\u003c\/em\u003e grabación cortical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKit de Inicio\u003c\/h2\u003e\n\u003cp\u003eIncluido con el ISO-80 viene un Kit de Inicio que contiene los siguientes accesorios necesarios para la investigación básica de electrofisiología con electrodos metálicos:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCBL102 Cable, BNC a conector de 3.5 mm, 6 pies (2 m) (dos)\u003c\/li\u003e\n\u003cli\u003e5469 Adaptador, mini-banana a toma de 0.031 (dos)\u003c\/li\u003e\n\u003cli\u003e13388 Adaptador, mini-banana a toma de 2 mm (dos)\u003c\/li\u003e\n\u003cli\u003e3294 Cable, clip de tierra a cable, 3 pies.\u003c\/li\u003e\n\u003cli\u003e2033 Conector mini-banana, negro\u003c\/li\u003e\n\u003cli\u003e2034 Conector mini-banana, rojo\u003c\/li\u003e\n\u003cli\u003e2035 Conector mini-banana soldable para torreta (dos)\u003c\/li\u003e\n\u003cli\u003eEP1 Pellets de Ag\/AgCl (cable de 70 mm) 1 mm de diámetro x 2.5 mm de largo\u003c\/li\u003e\n\u003cli\u003eM3301EH Soporte para electrodo, 14 cm (dos)\u003c\/li\u003e\n\u003cli\u003e5470 conector de 0.031 pulgadas en cable de 12 pulgadas (paquete de 4)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAplicaciones \u003c\/h2\u003e\n\u003cp\u003eHay múltiples aplicaciones disponibles con una variedad de opciones. Aquí puede ver dos configuraciones.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAPLICACIÓN DIFERENCIAL PARA ELECTRODOS METÁLICOS \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEn esta configuración, se utilizan electrodos metálicos con un amplificador diferencial. En esta configuración, se muestra un DAM80, pero fácilmente podría sustituirse por un DAM50 (con 5489), ISO-DAM8A (con 74040) o ISO-80.\u003c\/p\u003e\n\u003cp\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/damsetup2_8a2961a4-1f39-49ef-ab00-60e275e65aeb.jpg?v=1765946604\" alt=\"Aplicación diferencial para electrodos metálicos\" width=\"496\" height=\"330\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ISO-80-Differential-application_6864d541-4bcb-4b2a-9cd9-3a3ce4ee6307.jpg?v=1765946610\" alt=\"Configuración de aplicación diferencial ISO-80\" width=\"85%\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ISO-80-optional-differential-application_7a67ab31-386d-4b3a-a88c-a0a0f42ff0ac.jpg?v=1765946615\" alt=\"Configuración de aplicación diferencial con ISO-80\" width=\"75%\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAPLICACIONES EXTRACELULARES UTILIZANDO VIDRIO\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePara casos raros al usar amplificadores extracelulares con vidrio, puede usar la configuración mostrada a continuación. En esta configuración se muestra un DAM80, pero fácilmente podría sustituirse por un ISODAM8A (con 74040) o ISO-80. Asimismo, esta configuración muestra el mango 2505 (1\/4\" - 6.3mm), pero si tiene un micromanipulador más pequeño, puede necesitar el mango 5444 (3\/16\" - 4.8mm). En esta ilustración se usa MEH7W-10, pero se podría usar cualquier MEH7W del tamaño de vidrio. (MEH7W-10 es vidrio de 1.0mm, MEH7W-12 es vidrio de 1.2mm, MEH7W-15 es vidrio de 1.5mm y MEH7W-20 es vidrio de 2.0mm.) EP2 se usa para conexión a tierra en la ilustración.\u003c\/p\u003e\n\u003cp\u003ePara aplicaciones de un solo extremo, sin embargo, un adaptador de cable 2033 en el conector negro puede conectarse al cable 3294. La punta utilizada depende de sus necesidades específicas. En la ilustración, se sugirió TIP1TW1. NOTA que el vidrio no se muestra en la ilustración a continuación. \u003cspan style=\"font-size: 12pt; line-height: 1.3em;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"margin: 5px; width: 469px; height: 418px;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/damsetup1_45eab984-e1ff-407c-b1cd-2933fc4572f4.jpg?v=1765946621\" alt=\"Aplicaciones extracelulares utilizando vidrio\" width=\"469\" height=\"418\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ISO-80-single-ended-application_4ec40597-4d80-4e2a-8b62-d2ca8874bcb8.jpg?v=1765946627\" alt=\"Aplicación de un solo extremo ISO-80\" width=\"80%\"\u003e\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ISO-80_IM.pdf\" target=\"_self\"\u003eManual ISO-80\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResistencia de Entrada\u003c\/td\u003e\r\n\u003ctd\u003e10\u003csup\u003e11\u003c\/sup\u003eΩ, modo común y diferencial\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eCorriente de fuga de entrada\u003c\/td\u003e\r\n\u003ctd\u003e50 pA, máx.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAmplificación\u003c\/td\u003e\r\n\u003ctd\u003ex10\u003csup\u003e2\u003c\/sup\u003e, x10\u003csup\u003e3\u003c\/sup\u003e, x10\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eRelación de rechazo de modo común\u003c\/td\u003e\r\n\u003ctd\u003e100 dB típico @ 50\/60 Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSeñal de ruido equivalente de entrada\u003c\/td\u003e\r\n\u003ctd\u003e0.4 µV rms (0.1-100 Hz) 2.0 µV rms (1 Hz - 10 kHz)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eConfiguración de filtros: Baja frecuencia\u003c\/td\u003e\r\n\u003ctd\u003e5, 10, 100, 300 Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eConfiguración de filtros: Alta frecuencia\u003c\/td\u003e\r\n\u003ctd\u003e100 Hz, 1, 3, 10 kHz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eMáximo rango de voltaje de salida\u003c\/td\u003e\r\n\u003ctd\u003e±8 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRango de impedancia del electrodo\u003c\/td\u003e\r\n\u003ctd\u003e100 kΩ - 10 MΩ @ 300Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eCorriente de estimulación\u003c\/td\u003e\r\n\u003ctd\u003e0 a ±20 µA (corriente constante)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eVoltaje máximo de ESTIMULACIÓN\u003c\/td\u003e\r\n\u003ctd\u003e±15 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eVoltaje máximo del electrodo\u003c\/td\u003e\r\n\u003ctd\u003e±40 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ePantalla\u003c\/td\u003e\r\n\u003ctd\u003eLCD de 3.5 dígitos\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003ePRUEBA DE PILA\u003c\/td\u003e\r\n\u003ctd\u003eIndicador de batería baja\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ePotencia\u003c\/td\u003e\r\n\u003ctd\u003eDos baterías Ni-MH de 9 V y cargador, incluidos\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003ePESO DE ENVÍO\u003c\/td\u003e\r\n\u003ctd\u003e4 lb. (1.8 kg)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42272862208090,"sku":"ISO-80","price":3750.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/iso-80_2_37987a43-ec63-417a-b2f5-da9b815b074a.jpg?v=1766398221"},{"product_id":"sys-dam50-dam50-extracellular-amplifier","title":"Amplificador Extracelular DAM50","description":"\u003c!-- section:details --\u003e\n\u003cp\u003eVea la \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/DAM_DS.pdf\"\u003eFicha técnica\u003c\/a\u003e actual.\u003c\/p\u003e\n\u003cp\u003eVea lo que necesita \u003ca href=\"\/es\/blog\/post\/wpi-s-low-noise-amplifiers-outperform-cheap-imitations\"\u003e saber antes de comprar un amplificador\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eUna familia de amplificadores de muy bajo ruido operados con batería\u003c\/h2\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAlimentado por batería para eliminar el ruido de la red\u003c\/li\u003e\n\u003cli\u003eFiltrado de paso alto y paso bajo\u003c\/li\u003e\n\u003cli\u003eOperación unipolar o diferencial\u003c\/li\u003e\n\u003cli\u003eAmplificación CC\/CA\u003c\/li\u003e\n\u003cli\u003ePosicionamiento variable de salida\u003c\/li\u003e\n\u003cli\u003eConstruido con componentes de alta calidad para asegurar un ruido intrínseco (de disparo) mínimo\u003c\/li\u003e\n\u003cli\u003ePortátil\u003c\/li\u003e\n\u003cli\u003eMontable en rack\u003c\/li\u003e\n\u003cli\u003eEl paquete DAM50 ahora incluye el cable de electrodo metálico blindado 300647 y un cable modular blindado.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBeneficios\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRuido interno muy bajo\u003c\/li\u003e\n\u003cli\u003eFuente de alimentación de CC ultra silenciosa — no requiere CA\u003c\/li\u003e\n\u003cli\u003eBaja susceptibilidad intrínseca a bucles de tierra\u003c\/li\u003e\n\u003cli\u003ePequeña huella\u003c\/li\u003e\n\u003cli\u003eRentable\u003c\/li\u003e\n\u003cli\u003e¡Protección contra descarga electrostática!\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAmplificación de biopotenciales de electrodos metálicos\u003c\/li\u003e\n\u003cli\u003eEstimulación de campo en cortes cerebrales\u003c\/li\u003e\n\u003cli\u003eEAG (Electroantenograma)\u003c\/li\u003e\n\u003cli\u003eERG (Electrorretinograma)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eReducción de ruido con amplificación diferencial\u003c\/h2\u003e\n\u003cp\u003eLa amplificación diferencial es de gran importancia en la grabación bioeléctrica para reducir el efecto siempre presente de interferencia de ruido por inducción de la línea eléctrica. Un amplificador diferencial bien diseñado disminuirá significativamente el ruido de la línea eléctrica (red). Es esencial que la preparación esté conectada con un electrodo a una buena tierra eléctrica, así como al cable de tierra del propio DAM50. Esto debería tener el efecto de reducir en gran medida el potencial inducido electrostáticamente. Además de la tierra de la preparación, se deben hacer dos conexiones de entrada diferenciales mediante electrodos apropiados aplicados al sitio de grabación para registrar de manera óptima una diferencia de potencial bioeléctrico.\u003c\/p\u003e\n\u003ch2\u003eTabla comparativa de características\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #0081c2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eTipo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eDAM50\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eDAM80\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eModo de entrada\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eCA\/CC\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguración de entrada\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eDiferencial\/Unipolar\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eDiferencial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eRango de ganancia\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e100-10,000 (CA)\u003cbr\u003e10-1,000 (CC)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e100 - 10,000 (CA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiltros de paso alto\/bajo\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eSí\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eSí\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eControl de posición de compensación\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eSí\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eSí\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerador de corriente\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eSí\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eCabezal activo remoto\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eSí\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConexión de salida\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBNC\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eMini jack de 3.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eConexión de entrada estándar\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003ecable sin terminar\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eMini banana\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuente de alimentación\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e(2) baterías alcalinas de 9V\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e(2) baterías alcalinas de 9V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e      \u003c\/p\u003e\n\u003ch2\u003eAplicaciones diferenciales para electrodos metálicos\u003c\/h2\u003e\n\u003cp\u003eLas imágenes a continuación muestran dos aplicaciones para electrodos metálicos.  \u003c\/p\u003e\n\u003cp\u003eEn este primer ejemplo, un pellet de electrodo RC1T Ag\/AgCl sellado está cableado al cable del amplificador. Esto también muestra una configuración diferencial.\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"500\" width=\"500\" alt=\"DAM50\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/DAM50_Aa01_cc0dd12a-941d-47e2-91dd-a76af6401480.jpg?v=1765947822\"\u003e\u003c\/p\u003e\n\u003cp\u003eEste segundo ejemplo muestra un pellet de electrodo EP2 plata\/cloruro de plata conectado al adaptador de amplificador 5389. Esto muestra una configuración diferencial. El EP2 es adecuado para su uso en una aplicación craneal de ratón. Para ello, necesita un cable de extensión 3294 para conectarlo al adaptador 5389.\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"500\" width=\"500\" alt=\"Dam50\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/DAM50_Ba01_6829c3a7-86d8-49dc-af3e-7d0aa3ffb495.jpg?v=1765947828\"\u003e\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/dam50-im-082208.pdf\"\u003eManual de instrucciones DAM50\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eIMPEDANCIA DE ENTRADA\u003c\/td\u003e\r\n\u003ctd\u003e10\u003csup\u003e12\u003c\/sup\u003e Ω, modo común y diferencial\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eCORRIENTE DE FUGA DE ENTRADA\u003c\/td\u003e\r\n\u003ctd\u003e50 pA (típico)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSEÑAL DIFERENCIAL MÁXIMA DC\u003c\/td\u003e\r\n\u003ctd\u003e±2.5 V (DAM 50)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eGANANCIA\u003c\/td\u003e\r\n\u003ctd\u003eAC: 100x, 1000x, 10000x, DC: 10x, 100x, 1000x (DAM50)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRELACIÓN DE RECHAZO DE MODO COMÚN\u003c\/td\u003e\r\n\u003ctd\u003e100dB @ 50\/60 Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eCAPACITANCIA DE ENTRADA\u003c\/td\u003e\r\n\u003ctd\u003e20 pF\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRUIDO EN MODO AC\u003c\/td\u003e\r\n\u003ctd\u003e0.4 μV RMS (2uV p-p) 0.1-100 Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eRUIDO EN MODO AC\u003c\/td\u003e\r\n\u003ctd\u003e2.6 μV RMS (10uV p-p) 1 Hz-10 kH\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRUIDO EN MODO DC (DAM50)\u003c\/td\u003e\r\n\u003ctd\u003e(DAM50) 7.5uV RMS (30uV p-p) 3-10 kHz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eAJUSTES DE FILTRO DE ANCHO DE BANDA: Modo AC\u003c\/td\u003e\r\n\u003ctd\u003eBaja frecuencia, 0.1, 1, 10, 300 Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAJUSTES DE FILTRO DE ANCHO DE BANDA: Modo DC (DAM50)\u003c\/td\u003e\r\n\u003ctd\u003eAlta frecuencia, 0.1, 1, 3, 10 kHz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eCONECTORES DE SALIDA\u003c\/td\u003e\r\n\u003ctd\u003eBNC\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRANGO DE VOLTAJE DE SALIDA\u003c\/td\u003e\r\n\u003ctd\u003e±8 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eIMPEDANCIA DE SALIDA\u003c\/td\u003e\r\n\u003ctd\u003e470 Ω\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ePRUEBA DE PILA\u003c\/td\u003e\r\n\u003ctd\u003eTono audible\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eSEÑAL DEL CALIBRADOR\u003c\/td\u003e\r\n\u003ctd\u003eOnda cuadrada de 10 Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ePOSICIÓN\u003c\/td\u003e\r\n\u003ctd\u003eAproximadamente 250 mV\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eCOMANDO EXTERNO\u003c\/td\u003e\r\n\u003ctd\u003eComandos de voltaje de entrada ±10 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eForma de onda de corriente AC o DC\u003c\/td\u003e\r\n\u003ctd\u003e±50μA amplitud máxima @ 200 KΩ\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003ePILAS\u003c\/td\u003e\r\n\u003ctd\u003e2 x 9 V alcalinas (incluidas)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDIMENSIONES:DAM50\u003c\/td\u003e\r\n\u003ctd\u003e8 x 4 x 1.75 in. (20.3 x 10.2 x 4.4 cm)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003ePESO DE ENVÍO\u003c\/td\u003e\r\n\u003ctd\u003e3.5 lb. (1.6 kg)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003eLos siguientes gráficos de ancho de banda para el DAM50 muestran la respuesta del amplificador cuando se usan varios filtros y ganancias. Para imágenes más grandes, haga clic en las miniaturas a continuación. \u003c\/p\u003e\r\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/dam50_graph005.jpg\"\u003e\u003cimg style=\"margin: 5px;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/dam50_graph005sm.jpg\" alt=\"Gráficos de ancho de banda para el DAM50\" width=\"288\" height=\"182\"\u003e\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cem\u003eGANANCIAS: Este gráfico muestra el corte estándar de frecuencia de 3dB en \u003c\/em\u003e el máximo paso de banda del filtro.\u003c\/p\u003e\r\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/dam50_graph004.jpg\"\u003e\u003cimg style=\"margin: 5px;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/dam50_graph004sm.jpg\" alt=\"La frecuencia estándar de 3dB\" width=\"288\" height=\"178\"\u003e\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cem\u003eFILTROS: Se aplicaron varios filtros pasa bajos y pasa altos en la configuración de ganancia AC x1000 para mostrar el ancho de banda y el amplificador DAM50 real. \u003c\/em\u003e\u003c\/p\u003e\n\u003c!-- \/section:specifications --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKim, E. Y., \u0026amp; Virginia, W. (s.f.). Efecto de la hormona del crecimiento en la función sináptica del hipocampo durante la privación de sueño.\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003efull-text. (s.f.).\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eDai, J., Brooks, D. I., \u0026amp; Sheinberg, D. L. (s.f.). Información suplementaria: La optogenética y la microestimulación eléctrica sesgan sistemáticamente la elección visuoespacial en primates.\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eŠkorjanc, A., \u0026amp; Belušič, G. (s.f.). Cómo enseñamos: Proyectos de investigación en aula y laboratorio sobre el flujo sanguíneo y el efecto de sustancias vasoactivas en vasos sanguíneos cutáneos de Xenopus laevis.\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eLiu, Y., Wang, Y., Zhu, G., Sun, J., Bi, X., \u0026amp; Baudry, M. (2016). Un inhibidor selectivo de calpaina-2 mejora el aprendizaje y la memoria al prolongar la activación de ERK. \u003ci\u003eNeuropharmacology\u003c\/i\u003e, \u003ci\u003e105\u003c\/i\u003e, 471–477. \u003ca href=\"http:\/\/doi.org\/10.1016\/j.neuropharm.2016.02.022\"\u003ehttp:\/\/doi.org\/10.1016\/j.neuropharm.2016.02.022\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eZtaou, S., Maurice, N., Camon, J., Guiraudie-Capraz, G., Kerkerian-Le Goff, L., Beurrier, C., … Amalric, M. (2016). Participación de interneuronas colinérgicas estriatales y receptores muscarínicos M1 y M4 en los síntomas motores de la enfermedad de Parkinson. \u003ci\u003eJournal of Neuroscience\u003c\/i\u003e, \u003ci\u003e36\u003c\/i\u003e(35).\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKentish, S. S. J., Frisby, C. L., Kritas, S., Li, H., Hatzinikolas, G., O’Donnell, T. A., … Ahern, G. (2015). Canales TRPV1 y señalización aferente vagal gástrica en ratones delgados y obesos inducidos por dieta alta en grasas. \u003ci\u003ePloS One\u003c\/i\u003e, \u003ci\u003e10\u003c\/i\u003e(8), e0135892. \u003ca href=\"http:\/\/doi.org\/10.1371\/journal.pone.0135892\"\u003ehttp:\/\/doi.org\/10.1371\/journal.pone.0135892\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eBlauvelt, D. G., Sato, T. F., Wienisch, M., \u0026amp; Murthy, V. N. (2013). Actividad espaciotemporal distinta en neuronas principales del bulbo olfatorio de ratón en estados anestesiado y despierto. \u003ci\u003eFrontiers in Neural Circuits\u003c\/i\u003e, \u003ci\u003e7\u003c\/i\u003e. \u003ca href=\"http:\/\/doi.org\/10.3389\/fncir.2013.00046\"\u003ehttp:\/\/doi.org\/10.3389\/fncir.2013.00046\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eBlaise, J. H. (2013). Potenciación a largo plazo de la sinapsis de la vía perforante al giro dentado en ratones en libertad. \u003ci\u003eJournal of Visualized Experiments\u003c\/i\u003e, (81), e50642. \u003ca href=\"http:\/\/doi.org\/10.3791\/50642\"\u003ehttp:\/\/doi.org\/10.3791\/50642\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eWang, H., Siddharthan, V., Kesler, K. K., Hall, J. O., Motter, N. E., Julander, J. G., \u0026amp; Morrey, J. D. (2013). La insuficiencia respiratoria neurológica fatal es común entre las encefalitis virales. \u003ci\u003eThe Journal of Infectious Diseases\u003c\/i\u003e, \u003ci\u003e208\u003c\/i\u003e(4), 573–83. \u003ca href=\"http:\/\/doi.org\/10.1093\/infdis\/jit186\"\u003ehttp:\/\/doi.org\/10.1093\/infdis\/jit186\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eZhang, Q.-X., Lu, R.-W., Curcio, C. A., Yao, X.-C., DC., H., SE., N., … PN, D. (2012). Identificación in vivo de señales ópticas intrínsecas confocales de disfunción retiniana localizada. \u003ci\u003eInvestigative Opthalmology \u0026amp; Visual Science\u003c\/i\u003e, \u003ci\u003e53\u003c\/i\u003e(13), 8139. \u003ca href=\"http:\/\/doi.org\/10.1167\/iovs.12-10732\"\u003ehttp:\/\/doi.org\/10.1167\/iovs.12-10732\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eBadsha, F., Kain, P., Prabhakar, S., Sundaram, S., Padinjat, R., Rodrigues, V., \u0026amp; Hasan, G. (2012). Mutantes en canales TRPC de Drosophila reducen la sensibilidad olfativa al dióxido de carbono. \u003ci\u003ePloS One\u003c\/i\u003e, \u003ci\u003e7\u003c\/i\u003e(11), e49848. \u003ca href=\"http:\/\/doi.org\/10.1371\/journal.pone.0049848\"\u003ehttp:\/\/doi.org\/10.1371\/journal.pone.0049848\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKonow, N., Azizi, E., \u0026amp; Roberts, T. J. (2012). Atenuación de la potencia muscular por el tendón durante la disipación de energía. \u003ci\u003eProceedings. Biological Sciences \/ The Royal Society\u003c\/i\u003e, \u003ci\u003e279\u003c\/i\u003e(1731), 1108–13. \u003ca href=\"http:\/\/doi.org\/10.1098\/rspb.2011.1435\"\u003ehttp:\/\/doi.org\/10.1098\/rspb.2011.1435\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eChen, S., Mohajerani, M. H., Xie, Y., \u0026amp; Murphy, T. H. (2012). Análisis optogenético de la excitabilidad neuronal durante isquemia global revela déficits selectivos en el procesamiento sensorial tras la reperfusión en la corteza de ratón. \u003ci\u003eThe Journal of Neuroscience : The Official Journal of the Society for Neuroscience\u003c\/i\u003e, \u003ci\u003e32\u003c\/i\u003e(39), 13510–9. \u003ca href=\"http:\/\/doi.org\/10.1523\/JNEUROSCI.1439-12.2012\"\u003ehttp:\/\/doi.org\/10.1523\/JNEUROSCI.1439-12.2012\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eMorrey, J. D., Siddharthan, V., Wang, H., Hall, J. O., Motter, N. E., Skinner, R. D., \u0026amp; Skirpstunas, R. T. (2010). Supresión neurológica de electromiografías del diafragma en hámsters infectados con el virus del Nilo Occidental. \u003ci\u003eJournal of Neurovirology\u003c\/i\u003e, \u003ci\u003e16\u003c\/i\u003e(4), 318–329. \u003ca href=\"http:\/\/doi.org\/10.3109\/13550284.2010.501847\"\u003ehttp:\/\/doi.org\/10.3109\/13550284.2010.501847\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eBrundage, C. M., \u0026amp; Taylor, B. E. (2010). Neuroplasticidad de la respuesta ventilatoria central hipercápnica: deterioro inducido por teratógenos y recuperación posterior durante el desarrollo. \u003ci\u003eDevelopmental Neurobiology\u003c\/i\u003e, \u003ci\u003e70\u003c\/i\u003e(10), 726–35. \u003ca href=\"http:\/\/doi.org\/10.1002\/dneu.20806\"\u003ehttp:\/\/doi.org\/10.1002\/dneu.20806\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKim, E., Grover, L. M., Bertolotti, D., \u0026amp; Green, T. L. (2010). La hormona del crecimiento rescata la función sináptica del hipocampo tras la privación de sueño. \u003ci\u003eAmerican Journal of Physiology. Regulatory, Integrative and Comparative Physiology\u003c\/i\u003e, \u003ci\u003e298\u003c\/i\u003e(6), R1588-96. \u003ca href=\"http:\/\/doi.org\/10.1152\/ajpregu.00580.2009\"\u003ehttp:\/\/doi.org\/10.1152\/ajpregu.00580.2009\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKavlie, R. G., Kernan, M. J., \u0026amp; Eberl, D. F. (2010). La audición en Drosophila requiere TilB, una proteína conservada asociada con la motilidad ciliar. \u003ci\u003eGenetics\u003c\/i\u003e, \u003ci\u003e185\u003c\/i\u003e(1), 177–88. \u003ca href=\"http:\/\/doi.org\/10.1534\/genetics.110.114009\"\u003ehttp:\/\/doi.org\/10.1534\/genetics.110.114009\u003c\/a\u003e \u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eLenti, L., Domoki, F., Gáspár, T., Snipes, J. A., Bari, F., \u0026amp; Busija, D. W. (2009). N-Metil-d-Aspartato induce hiperemia cortical mediante mecanismos dependientes e independientes de la depresión cortical propagada en ratas. \u003ci\u003eMicrocirculation\u003c\/i\u003e, \u003ci\u003e16\u003c\/i\u003e(7), 629–639. \u003ca href=\"http:\/\/doi.org\/10.1080\/10739680903131510\"\u003ehttp:\/\/doi.org\/10.1080\/10739680903131510\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eSu, C.-K., Ho, C.-M., Kuo, H.-H., Wen, Y.-C., \u0026amp; Chai, C.-Y. (2009). Expresión de c-Fos correlacionada con el sistema simpático en la médula espinal de ratas neonatales in vitro. \u003ci\u003eJournal of Biomedical Science\u003c\/i\u003e, \u003ci\u003e16\u003c\/i\u003e(1), 44. \u003ca href=\"http:\/\/doi.org\/10.1186\/1423-0127-16-44\"\u003ehttp:\/\/doi.org\/10.1186\/1423-0127-16-44\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eBrundage, C. M., \u0026amp; Taylor, B. E. (2009). El momento y la duración de la exposición al nicotina durante el desarrollo contribuyen a la atenuación de la respuesta neuroventilatoria hipercápnica en renacuajos. \u003ci\u003eDevelopmental Neurobiology\u003c\/i\u003e, \u003ci\u003e69\u003c\/i\u003e(7), 451–61. \u003ca href=\"http:\/\/doi.org\/10.1002\/dneu.20720\"\u003ehttp:\/\/doi.org\/10.1002\/dneu.20720\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eOrem, N. R., Xia, L., \u0026amp; Dolph, P. J. (2006). Un papel esencial para la endocitosis de rodopsina mediante la interacción de la arrestina visual con el adaptador AP-2. \u003ci\u003eJournal of Cell Science\u003c\/i\u003e, \u003ci\u003e119\u003c\/i\u003e(Pt 15), 3141–8. \u003ca href=\"http:\/\/doi.org\/10.1242\/jcs.03052\"\u003ehttp:\/\/doi.org\/10.1242\/jcs.03052\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eMarkham, M. R., \u0026amp; Stoddard, P. K. (2005). La hormona adrenocorticotrópica mejora la masculinidad de una señal eléctrica de comunicación al modular la forma de onda y el tiempo de los potenciales de acción dentro de células individuales. \u003ci\u003eThe Journal of Neuroscience : The Official Journal of the Society for Neuroscience\u003c\/i\u003e, \u003ci\u003e25\u003c\/i\u003e(38), 8746–54. \u003ca href=\"http:\/\/doi.org\/10.1523\/JNEUROSCI.2809-05.2005\"\u003ehttp:\/\/doi.org\/10.1523\/JNEUROSCI.2809-05.2005\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eCartford, M. C. (2004). La norepinefrina cerebelosa modula el aprendizaje del condicionamiento clásico de parpadeo con retardo: Evidencia de señalización postsináptica vía PKA. \u003ci\u003eLearning \u0026amp; Memory\u003c\/i\u003e, \u003ci\u003e11\u003c\/i\u003e(6), 732–737. \u003ca href=\"http:\/\/doi.org\/10.1101\/lm.83104\"\u003ehttp:\/\/doi.org\/10.1101\/lm.83104\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eJonker, D. M., Vermeij, D. A. C., Edelbroek, P. M., Voskuyl, R. A., Piotrovsky, V. K., \u0026amp; Danhof, M. (2003). Análisis farmacodinámico de la interacción entre Tiagabina y Midazolam con un modelo alostérico que incorpora la transducción de señales. \u003ci\u003eEpilepsia\u003c\/i\u003e, \u003ci\u003e44\u003c\/i\u003e(3), 329–338. \u003ca href=\"http:\/\/doi.org\/10.1046\/j.1528-1157.2003.37802.x\"\u003ehttp:\/\/doi.org\/10.1046\/j.1528-1157.2003.37802.x\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003evan den Pol, A. N., Ghosh, P. K., Liu, R., Li, Y., Aghajanian, G. K., \u0026amp; Gao, X.-B. (2002). La hipocretina (orexina) aumenta la actividad neuronal y la sincronía celular en el locus coeruleus en desarrollo de ratones que expresan GFP. \u003ci\u003eThe Journal of Physiology\u003c\/i\u003e, \u003ci\u003e541\u003c\/i\u003e(1), 169–185. \u003ca href=\"http:\/\/doi.org\/10.1113\/jphysiol.2002.017426\"\u003ehttp:\/\/doi.org\/10.1113\/jphysiol.2002.017426\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eRansom, C. B., Ransom, B. R., \u0026amp; Sontheimer, H. (2000). Acumulación extracelular de K+ dependiente de la actividad en el nervio óptico de rata: el papel de las bombas de Na+ gliales y axonales. \u003ci\u003eThe Journal of Physiology\u003c\/i\u003e, \u003ci\u003e522 Pt 3\u003c\/i\u003e, 427–42. Recuperado de \u003ca href=\"http:\/\/www.pubmedcentral.nih.gov\/articlerender.fcgi?artid=2269766\u0026amp;tool=pmcentrez\u0026amp;rendertype=abstract\"\u003ehttp:\/\/www.pubmedcentral.nih.gov\/articlerender.fcgi?artid=2269766\u0026amp;tool=pmcentrez\u0026amp;rendertype=abstract\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eAlloway, P. G., \u0026amp; Dolph, P. J. (1999). Un papel para la fosforilación dependiente de la luz de la arrestina visual. \u003ci\u003eProceedings of the National Academy of Sciences\u003c\/i\u003e, \u003ci\u003e96\u003c\/i\u003e(11), 6072–6077. \u003ca href=\"http:\/\/doi.org\/10.1073\/pnas.96.11.6072\"\u003ehttp:\/\/doi.org\/10.1073\/pnas.96.11.6072\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eLipchik, G. L., Holroyd, K. A., France, C. R., Kvaal, S. A., Segal, D., Cordingley, G. E., … McCool, H. R. (1996). Mecanismos centrales y periféricos en la cefalea tensional crónica. \u003ci\u003ePain\u003c\/i\u003e, \u003ci\u003e64\u003c\/i\u003e(3), 467–75. Recuperado de \u003ca href=\"http:\/\/www.pubmedcentral.nih.gov\/articlerender.fcgi?artid=2128054\u0026amp;tool=pmcentrez\u0026amp;rendertype=abstract\"\u003ehttp:\/\/www.pubmedcentral.nih.gov\/articlerender.fcgi?artid=2128054\u0026amp;tool=pmcentrez\u0026amp;rendertype=abstract\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKnuckey, N. W., Palm, D., Primiano, M., Epstein, M. H., \u0026amp; Johanson, C. E. (1995). La N-Acetilcisteína mejora la supervivencia neuronal en el hipocampo tras isquemia transitoria del cerebro anterior en ratas. \u003ci\u003eStroke\u003c\/i\u003e, \u003ci\u003e26\u003c\/i\u003e(2), 305–311. \u003ca href=\"http:\/\/doi.org\/10.1161\/01.STR.26.2.305\"\u003ehttp:\/\/doi.org\/10.1161\/01.STR.26.2.305\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42272907067482,"sku":"SYS-DAM50","price":2100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/dam50-cable_f63449e3-728b-4aa5-8ae4-b8de3c817ee7.png?v=1766399605"},{"product_id":"sys-dam80-extracellular-amplifier-with-active-probe","title":"Amplificador Extracelular con Sonda Activa","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eUna familia de amplificadores extracelulares operados con batería y de muy bajo ruido\u003c\/h2\u003e\n\u003cp\u003eEl Kit de Inicio DAM80 incluye: 2-CBL102, 5469, 2-13388, 3294, 2033, 2034, 2-2035\u003c\/p\u003e\n\u003cp\u003eVea la \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/DAM_DS.pdf\"\u003eFicha Técnica\u003c\/a\u003e actual.\u003c\/p\u003e\n\u003cp\u003eVea lo que necesita \u003ca href=\"\/es\/blog\/post\/wpi-s-low-noise-amplifiers-outperform-cheap-imitations\"\u003esaber antes de comprar un amplificador\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAlimentado por batería para eliminar ruido de línea\u003c\/li\u003e\n\u003cli\u003eFiltrado pasa altos y pasa bajos\u003c\/li\u003e\n\u003cli\u003eOperación simple o diferencial\u003c\/li\u003e\n\u003cli\u003eSolo amplificación de CA\u003c\/li\u003e\n\u003cli\u003eIncluye etapa activa de bajo ruido\u003c\/li\u003e\n\u003cli\u003ePosicionamiento de salida variable\u003c\/li\u003e\n\u003cli\u003eConstruido con componentes de alta calidad para asegurar un ruido intrínseco (de disparo) mínimo\u003c\/li\u003e\n\u003cli\u003ePortátil\u003c\/li\u003e\n\u003cli\u003eMontable en rack\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBeneficios\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRuido interno muy bajo\u003c\/li\u003e\n\u003cli\u003eFuente de alimentación de CC ultra silenciosa — no requiere CA\u003c\/li\u003e\n\u003cli\u003eBaja susceptibilidad intrínseca a bucles de tierra\u003c\/li\u003e\n\u003cli\u003ePequeña huella\u003c\/li\u003e\n\u003cli\u003eRentable\u003c\/li\u003e\n\u003cli\u003e¡Protección contra Descargas Electroestáticas!\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAmplificación de biopotenciales de electrodos metálicos\u003c\/li\u003e\n\u003cli\u003eEstimulación de campo en cortes cerebrales\u003c\/li\u003e\n\u003cli\u003eEAG (Electroantennograma)\u003c\/li\u003e\n\u003cli\u003eERG (Electrorretinograma)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eLos amplificadores de la serie \u003cstrong\u003eDAM\u003c\/strong\u003e de WPI son bien conocidos como un estándar de la industria para la amplificación de potenciales extracelulares. Estos bioamplificadores alimentados por batería están diseñados con un perfil compacto que permite al usuario ubicar la unidad más cerca de la preparación y así minimizar longitudes de cable que contribuyen al ruido. Cada amplificador está equipado con filtros seleccionables de alta y baja frecuencia, y un control de posición para compensar potenciales galvánicos que puedan desarrollarse durante la grabación.\u003c\/p\u003e\n\u003cp\u003eEl kit de inicio (incluido) se muestra en la imagen a continuación.\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"432\" width=\"576\" alt=\"El Kit de Inicio DAM80 incluye los componentes mostrados en la imagen.\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/dam80kit_992d4f69-2fd4-4886-8b14-9e75dd253c82.jpg?v=1765947842\" style=\"margin: 5px;\"\u003e\u003c\/p\u003e\n\u003ch2\u003eCabezal activo remoto\u003c\/h2\u003e\n\u003cp\u003eEl \u003cstrong\u003eDAM80\u003c\/strong\u003e, un amplificador solo de CA, cuenta con una sonda de etapa activa de muy bajo ruido que puede montarse en micromanipuladores para grabación cortical cercana, para grabación extracelular desde microelectrodos de vidrio o metal de alta impedancia. La unidad también proporciona una corriente con compuerta para marcado de tejido. Se recomienda el soporte para microelectrodos \u003ca href=\"\/es\/var-3814-microelectrode-holder-meh7w\"\u003e\u003cstrong\u003eMEH7W-XX\u003c\/strong\u003e\u003c\/a\u003e (se vende por separado) para microelectrodos de vidrio.\u003c\/p\u003e\n\u003ch2\u003eGeneración de Corriente\u003c\/h2\u003e\n\u003cp\u003eEl DAM80 es perfecto para generación de corriente con compuerta o manual para marcado histológico, iontoforesis o estimulación celular. Incluye una etapa activa remota de muy bajo ruido que es útil para amplificación de muy alta impedancia utilizando electrodos de vidrio o metal.\u003c\/p\u003e\n\u003ch2\u003ePortabilidad\u003c\/h2\u003e\n\u003cp\u003eLos amplificadores de la serie \u003cstrong\u003eDAM\u003c\/strong\u003e pueden usarse como unidades independientes sobre cualquier superficie, o utilizar el hardware opcional de montaje con abrazadera para ubicarlos convenientemente dentro del área de trabajo. Alternativamente, un par de amplificadores puede montarse en un rack estándar con un kit de montaje en rack (#\u003cstrong\u003e3484\u003c\/strong\u003e). Hay una variedad de accesorios de conexión disponibles para configurar su aplicación. \u003c\/p\u003e\n\u003ch2\u003eTabla comparativa de características\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #0081c2;\"\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eDAM50\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eDAM80\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eModo de entrada\u003c\/td\u003e\n\u003ctd\u003eCA\/CC\u003c\/td\u003e\n\u003ctd\u003eCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguración de entrada\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eDiferencial\/Unipolar\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eDiferencial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eRango de ganancia\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e100-10,000 (CA)\u003cbr\u003e10-1,000 (CC)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e100 - 10,000 (CA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiltros alto\/bajo\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eSí\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eSí\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eControl de posición de compensación\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eSí\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eSí\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerador de corriente\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eSí\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eCabezal activo remoto\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eSí\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConexión de salida\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBNC\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eMini jack de 3.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eConexión de entrada estándar\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003ecable sin terminar\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eMini banana\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuente de alimentación\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e(2) pilas alcalinas de 9V\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e(2) pilas alcalinas de 9V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"contentcontainer\" id=\"appnotescontainer\"\u003e\n\u003cp\u003eHay múltiples aplicaciones disponibles con una variedad de opciones. Aquí puede ver dos configuraciones.\u003c\/p\u003e\n\u003ch2\u003eAplicaciones diferenciales para electrodos de metal\u003c\/h2\u003e\n\u003cp\u003eEn esta configuración, se usan electrodos de metal con un amplificador diferencial. En esta configuración, se muestra un \u003ca href=\"\/es\/sys-dam80-extracellular-amplifier-with-active-probe\"\u003e\u003cstrong\u003eDAM80\u003c\/strong\u003e \u003c\/a\u003e, pero fácilmente podría sustituirse por un \u003ca href=\"\/es\/sys-dam50-dam50-extracellular-amplifier\"\u003e\u003cstrong\u003eDAM50\u003c\/strong\u003e \u003c\/a\u003e (con \u003ca href=\"\/es\/5489-optional-probe-for-dam50\"\u003e\u003cstrong\u003e5489\u003c\/strong\u003e\u003c\/a\u003e), \u003cstrong\u003eISO-DAM8A\u003c\/strong\u003e (con \u003ca href=\"\/es\/74040-iso-dam8a-active-headstage\"\u003e\u003cstrong\u003e74040\u003c\/strong\u003e\u003c\/a\u003e) o un \u003ca href=\"\/es\/iso-80-isolated-differential-amplifier-with-active-probe\"\u003e\u003cstrong\u003eISO-80\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"330\" width=\"496\" alt=\"APLICACIÓN DIFERENCIAL PARA ELECTRODOS DE METAL\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/damsetup2_21a259c3-95dc-41ab-923f-28dc4772870e.jpg?v=1765947848\"\u003e\u003c\/p\u003e\n\u003ch2\u003eAplicaciones extracelulares utilizando microelectrodos de vidrio\u003c\/h2\u003e\n\u003cp\u003ePara casos raros en los que se utilizan amplificadores extracelulares con vidrio, puede usar la configuración que se muestra a continuación. En esta configuración, se muestra un DAM80, pero fácilmente podría sustituirlo por un \u003cstrong\u003eISO-DAM8A\u003c\/strong\u003e (con \u003ca href=\"\/es\/74040-iso-dam8a-active-headstage\"\u003e\u003cstrong\u003e74040\u003c\/strong\u003e\u003c\/a\u003e) o un \u003ca href=\"\/es\/iso-80-isolated-differential-amplifier-with-active-probe\"\u003e\u003cstrong\u003eISO-80\u003c\/strong\u003e\u003c\/a\u003e. De igual manera, esta configuración muestra el mango \u003ca href=\"\/es\/2505-electrode-handle-63-mm\"\u003e\u003cstrong\u003e2505\u003c\/strong\u003e \u003c\/a\u003e (1\/4\" - 6.3mm), pero si tiene un micromanipulador más pequeño, puede necesitar el mango \u003ca href=\"\/es\/5444-electrode-handle-48-mm\"\u003e\u003cstrong\u003e5444\u003c\/strong\u003e \u003c\/a\u003e (3\/16\" - 4.8mm). En esta ilustración, se usa \u003ca rel=\"noopener\" href=\"\/es\/var-3814-microelectrode-holder-meh7w\" target=\"_blank\"\u003e\u003cstrong\u003eMEH7W-10\u003c\/strong\u003e \u003c\/a\u003e, pero podría usarse cualquier tamaño de vidrio \u003ca rel=\"noopener\" href=\"\/es\/var-3814-microelectrode-holder-meh7w\" target=\"_blank\"\u003e\u003cstrong\u003eMEH7W\u003c\/strong\u003e \u003c\/a\u003e. (\u003ca rel=\"noopener\" href=\"\/es\/var-3814-microelectrode-holder-meh7w\" target=\"_blank\"\u003e\u003cstrong\u003eMEH7W-10\u003c\/strong\u003e \u003c\/a\u003e es vidrio de 1.0mm, \u003ca rel=\"noopener\" href=\"\/es\/var-3814-microelectrode-holder-meh7w\" target=\"_blank\"\u003e\u003cstrong\u003eMEH7W-12\u003c\/strong\u003e \u003c\/a\u003e es vidrio de 1.2mm, \u003ca rel=\"noopener\" href=\"\/es\/var-3814-microelectrode-holder-meh7w\" target=\"_blank\"\u003e\u003cstrong\u003eMEH7W-15\u003c\/strong\u003e \u003c\/a\u003e es vidrio de 1.5mm y \u003ca href=\"\/es\/var-3814-microelectrode-holder-meh7w\"\u003e\u003cstrong\u003eMEH7W-20\u003c\/strong\u003e \u003c\/a\u003e es vidrio de 2.0mm.) Para la conexión a tierra en la ilustración se usa \u003ca href=\"\/es\/var-2739-ag-agcl-electrode\"\u003e\u003cstrong\u003eEP2\u003c\/strong\u003e \u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePara aplicaciones de un solo extremo, sin embargo, un adaptador de cable \u003ca href=\"\/es\/2033-black-insulated-mini-banana-plug\"\u003e\u003cstrong\u003e2033\u003c\/strong\u003e\u003c\/a\u003e en el conector negro puede conectarse al cable \u003ca href=\"\/es\/3294-ground-wire-for-dam80-probe\"\u003e\u003cstrong\u003e3294\u003c\/strong\u003e\u003c\/a\u003e. La punta utilizada depende de sus necesidades específicas. En la ilustración, se sugirió \u003ca href=\"\/es\/var-3564-pre-pulled-glass-pipettes\"\u003e\u003cstrong\u003eTIP1TW1\u003c\/strong\u003e \u003c\/a\u003e. NOTA que el vidrio no se muestra en la ilustración a continuación.\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"418\" width=\"469\" alt=\"APLICACIONES EXTRACELULARES UTILIZANDO VIDRIO\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/damsetup1_81b0fb71-843c-40ff-a980-343604d34af6.jpg?v=1765947854\" style=\"margin: 5px;\"\u003e\u003c\/p\u003e\n\u003cp\u003e   \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- \/section:details --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/DAM80_IMs.pdf\" target=\"_self\"\u003eManual de instrucciones DAM80\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:specifications --\u003e\n\u003ctable cellpadding=\"2\" cellspacing=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIMPEDANCIA DE ENTRADA\u003c\/td\u003e\n\u003ctd\u003e10\u003csup\u003e12 \u003c\/sup\u003eΩ, modo común y diferencial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eCORRIENTE DE FUGA DE ENTRADA\u003c\/td\u003e\n\u003ctd\u003e50 pA (típico)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRELACIÓN DE RECHAZO DE MODO COMÚN\u003c\/td\u003e\n\u003ctd\u003e100 dB @ 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eCAPACITANCIA DE ENTRADA\u003c\/td\u003e\n\u003ctd\u003e20 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRUIDO EN MODO AC\u003c\/td\u003e\n\u003ctd\u003e0.4 µV RMS (2uV p-p) 0.1-100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eRUIDO EN MODO AC\u003c\/td\u003e\n\u003ctd\u003e2.6 µV RMS (10uV p-p) 1Hz-10 kH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAJUSTES DEL FILTRO DE BANDA, Modo AC\u003c\/td\u003e\n\u003ctd\u003eBaja frecuencia, 0.1, 1, 10, 300 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eAJUSTES DEL FILTRO DE BANDA: Modo AC (DAM80)\u003c\/td\u003e\n\u003ctd\u003eAlta frecuencia, 0.1, 1, 3, 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCONECTORES DE SALIDA\u003c\/td\u003e\n\u003ctd\u003eConector MiniPhone de 3.5 mm en DAM80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eRANGO DE VOLTAJE DE SALIDA\u003c\/td\u003e\n\u003ctd\u003e±8V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIMPEDANCIA DE SALIDA\u003c\/td\u003e\n\u003ctd\u003e470 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003ePRUEBA DE PILA\u003c\/td\u003e\n\u003ctd\u003eTono audible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEÑAL DEL CALIBRADOR\u003c\/td\u003e\n\u003ctd\u003eOnda cuadrada de 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003ePOSICIÓN\u003c\/td\u003e\n\u003ctd\u003eAproximadamente 250 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFUENTE DE CORRIENTE:DAM80: Generador DC\u003c\/td\u003e\n\u003ctd\u003e0 a ±50 µA, variable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eCOMANDO EXTERNO\u003c\/td\u003e\n\u003ctd\u003eComandos de voltaje de entrada ±10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForma de onda de corriente AC o DC\u003c\/td\u003e\n\u003ctd\u003e±50 µA amplitud máxima @ 200 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003ePILAS\u003c\/td\u003e\n\u003ctd\u003e2 x 9 V alcalinas (incluidas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDIMENSIONES:DAM80\u003c\/td\u003e\n\u003ctd\u003e7 x 4 x 1.75 in. (17.8 x 10.2 x 4.4 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003ePESO DE ENVÍO\u003c\/td\u003e\n\u003ctd\u003e3.5 lb. (1.6 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:references --\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eDonnelly, W. T., Bartlett, D., \u0026amp; Leiter, J. C. (2016). La serotonina en el núcleo del tracto solitario acorta el quimiorreflejo laríngeo en ratas neonatales anestesiadas. \u003ci\u003eExperimental Physiology\u003c\/i\u003e, \u003ci\u003e101\u003c\/i\u003e(7), 946–961. \u003ca href=\"http:\/\/doi.org\/10.1113\/EP085716\"\u003ehttp:\/\/doi.org\/10.1113\/EP085716\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eFeng, B., Joyce, S. C., \u0026amp; Gebhart, G. F. (2016). Activación optogenética de aferentes mecánicamente insensibles en el colon-recto de ratón revela quimiosensibilidad. \u003ci\u003eAmerican Journal of Physiology - Gastrointestinal and Liver Physiology\u003c\/i\u003e, \u003ci\u003e310\u003c\/i\u003e(10).\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKaldenbach, F., Bleckmann, H., \u0026amp; Kohl, T. (2016). Respuestas de unidades tectales sensibles al infrarrojo de la víbora de foseta Crotalus atrox a objetos en movimiento. \u003ci\u003eJournal of Comparative Physiology A\u003c\/i\u003e, \u003ci\u003e202\u003c\/i\u003e(6), 389–398. \u003ca href=\"http:\/\/doi.org\/10.1007\/s00359-016-1076-1\"\u003ehttp:\/\/doi.org\/10.1007\/s00359-016-1076-1\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eMustafina, A. N., Koroleva, K. S., Giniatullin, R. A., \u0026amp; Sitdikova, G. F. (2016). Canales iónicos sensibles al ácido como objetivo del sulfuro de hidrógeno en neuronas trigeminales de rata. \u003ci\u003eBioNanoScience\u003c\/i\u003e, 1–3. \u003ca href=\"http:\/\/doi.org\/10.1007\/s12668-016-0237-6\"\u003ehttp:\/\/doi.org\/10.1007\/s12668-016-0237-6\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eOrton, L. D., Papasavvas, C. A., \u0026amp; Rees, A. (2016). El control de ganancia comisural mejora la representación en el mesencéfalo de la localización del sonido. \u003ci\u003eThe Journal of Neuroscience : The Official Journal of the Society for Neuroscience\u003c\/i\u003e, \u003ci\u003e36\u003c\/i\u003e(16), 4470–81. \u003ca href=\"http:\/\/doi.org\/10.1523\/JNEUROSCI.3012-15.2016\"\u003ehttp:\/\/doi.org\/10.1523\/JNEUROSCI.3012-15.2016\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003ePalanca-Castan, N., Laumen, G., Reed, D., \u0026amp; Köppl, C. (2016). El componente de interacción binaural en el búho común (Tyto alba) presenta pocas diferencias con respecto a datos de mamíferos. \u003ci\u003eJournal of the Association for Research in Otolaryngology\u003c\/i\u003e, 1–13. \u003ca href=\"http:\/\/doi.org\/10.1007\/s10162-016-0583-7\"\u003ehttp:\/\/doi.org\/10.1007\/s10162-016-0583-7\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eFeng, B., \u0026amp; Gebhart, G. F. (2015). \u0026amp;lt;em\u0026amp;gt;Caracterización funcional in vitro\u0026amp;lt;\/em\u0026amp;gt; de terminaciones aferentes colorrectales en ratón. \u003ci\u003eJournal of Visualized Experiments\u003c\/i\u003e, (95), e52310–e52310. \u003ca href=\"http:\/\/doi.org\/10.3791\/52310\"\u003ehttp:\/\/doi.org\/10.3791\/52310\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eGholami, M., Moradpour, F., Semnanian, S., Naghdi, N., \u0026amp; Fathollahi, Y. (2015). La administración crónica de salicilato de sodio mejora la potenciación a largo plazo del pico poblacional tras una combinación de estimulación en ráfaga primada a frecuencia theta y la aplicación transitoria de pentylenetetrazol en neuronas CA1 del hipocampo de rata. \u003ci\u003eEuropean Journal of Pharmacology\u003c\/i\u003e, \u003ci\u003e767\u003c\/i\u003e, 165–174. \u003ca href=\"http:\/\/doi.org\/10.1016\/j.ejphar.2015.10.021\"\u003ehttp:\/\/doi.org\/10.1016\/j.ejphar.2015.10.021\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKim, Y.-J., \u0026amp; Kang, T.-C. (2015). El papel de TRPC6 en la susceptibilidad a convulsiones y el daño neuronal relacionado con convulsiones en el giro dentado de la rata. \u003ci\u003eNeuroscience\u003c\/i\u003e, \u003ci\u003e307\u003c\/i\u003e, 215–230. \u003ca href=\"http:\/\/doi.org\/10.1016\/j.neuroscience.2015.08.054\"\u003ehttp:\/\/doi.org\/10.1016\/j.neuroscience.2015.08.054\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKulthinee, S., Wyss, J. M., \u0026amp; Roysommuti, S. (2015). La suplementación con taurina previene el efecto adverso de la ingesta alta de azúcar sobre el control de la presión arterial tras isquemia\/reperfusión cardíaca en ratas hembras. \u003ci\u003eAdvances in Experimental Medicine and Biology\u003c\/i\u003e, \u003ci\u003e803\u003c\/i\u003e, 597–611. \u003ca href=\"http:\/\/doi.org\/10.1007\/978-3-319-15126-7_48\"\u003ehttp:\/\/doi.org\/10.1007\/978-3-319-15126-7_48\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eBouabid, S., Delaville, C., De Deurwaerdère, P., Lakhdar-Ghazal, N., \u0026amp; Benazzouz, A. (2014). El parkinsonismo atípico inducido por manganeso se asocia con actividad alterada de los ganglios basales y cambios en los niveles tisulares de monoaminas en la rata. \u003ci\u003ePLoS ONE\u003c\/i\u003e, \u003ci\u003e9\u003c\/i\u003e(6), e98952. \u003ca href=\"http:\/\/doi.org\/10.1371\/journal.pone.0098952\"\u003ehttp:\/\/doi.org\/10.1371\/journal.pone.0098952\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eGal, R., Kaiser, M., Haspel, G., Libersat, F., Fouad, K., Libersat, F., … Yack, J. (2014). Arsenal sensorial en el aguijón de la avispa joya parasitoide y su posible papel en la identificación de cerebros de cucaracha. \u003ci\u003ePLoS ONE\u003c\/i\u003e, \u003ci\u003e9\u003c\/i\u003e(2), e89683. \u003ca href=\"http:\/\/doi.org\/10.1371\/journal.pone.0089683\"\u003ehttp:\/\/doi.org\/10.1371\/journal.pone.0089683\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eHuo, B.-X., Smith, J. B., \u0026amp; Drew, P. J. (2014). Acoplamiento y desacoplamiento neurovascular en la corteza durante la locomoción voluntaria. \u003ci\u003eThe Journal of Neuroscience : The Official Journal of the Society for Neuroscience\u003c\/i\u003e, \u003ci\u003e34\u003c\/i\u003e(33), 10975–81. \u003ca href=\"http:\/\/doi.org\/10.1523\/JNEUROSCI.1369-14.2014\"\u003ehttp:\/\/doi.org\/10.1523\/JNEUROSCI.1369-14.2014\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eHermann, P. M., Park, D., Beaulieu, E., \u0026amp; Wildering, W. C. (2013). Evidencia de disfunción de la memoria mediada por inflamación en gasterópodos: inhibidores putativos de PLA2 y COX abolieron el fallo de memoria a largo plazo inducido por desafíos inmunes sistémicos. \u003ci\u003eBMC Neuroscience\u003c\/i\u003e, \u003ci\u003e14\u003c\/i\u003e(1), 83. \u003ca href=\"http:\/\/doi.org\/10.1186\/1471-2202-14-83\"\u003ehttp:\/\/doi.org\/10.1186\/1471-2202-14-83\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKam, T.-I., Song, S., Gwon, Y., Park, H., Yan, J.-J., Im, I., … Jung, Y.-K. (2013). FcγRIIb media la neurotoxicidad del amiloide-β y el deterioro de la memoria en la enfermedad de Alzheimer. \u003ci\u003eThe Journal of Clinical Investigation\u003c\/i\u003e, \u003ci\u003e123\u003c\/i\u003e(7), 2791–802. \u003ca href=\"http:\/\/doi.org\/10.1172\/JCI66827\"\u003ehttp:\/\/doi.org\/10.1172\/JCI66827\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003ePark, H.-J., Bonmassar, G., Kaltenbach, J. A., Machado, A. G., Manzoor, N. F., \u0026amp; Gale, J. T. (2013). Activación del sistema nervioso central inducida por microestimulación magnética. \u003ci\u003eNature Communications\u003c\/i\u003e, \u003ci\u003e4\u003c\/i\u003e, 2463. \u003ca href=\"http:\/\/doi.org\/10.1038\/ncomms3463\"\u003ehttp:\/\/doi.org\/10.1038\/ncomms3463\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eSanchez-Jimenez, A., Torets, C., \u0026amp; Panetsos, F. (2013). Procesamiento complementario de la información háptica por neuronas de adaptación lenta y rápida en la vía trigeminotalámica. Electrofisiología, modelado matemático y simulaciones de neuronas relacionadas con vibrisas. \u003ci\u003eFrontiers in Cellular Neuroscience\u003c\/i\u003e, \u003ci\u003e7\u003c\/i\u003e, 79. \u003ca href=\"http:\/\/doi.org\/10.3389\/fncel.2013.00079\"\u003ehttp:\/\/doi.org\/10.3389\/fncel.2013.00079\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eSotoyama, H., Namba, H., Chiken, S., Nambu, A., \u0026amp; Nawa, H. (2013). La exposición a la citocina EGF conduce a una hiperactividad anormal de las neuronas GABA pallidales: implicaciones para la esquizofrenia y su modelado. \u003ci\u003eJournal of Neurochemistry\u003c\/i\u003e, \u003ci\u003e126\u003c\/i\u003e(4), 518–28. \u003ca href=\"http:\/\/doi.org\/10.1111\/jnc.12223\"\u003ehttp:\/\/doi.org\/10.1111\/jnc.12223\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eJirakulsomchok, D., Napawachirahat, S., Kunbootsri, N., Suttitum, T., Wannanon, P., Wyss, J. M., \u0026amp; Roysommuti, S. (2012). Respuesta renal deteriorada a la infusión portal de solución salina hipertónica en ratas tratadas con adriamicina. \u003ci\u003eClinical and Experimental Pharmacology and Physiology\u003c\/i\u003e, \u003ci\u003e39\u003c\/i\u003e(7), 636–641. \u003ca href=\"http:\/\/doi.org\/10.1111\/j.1440-1681.2012.05722.x\"\u003ehttp:\/\/doi.org\/10.1111\/j.1440-1681.2012.05722.x\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKato, Y. X., Furukawa, S., Samejima, K., Hironaka, N., \u0026amp; Kashino, M. (2012). Método basado en poliimida fotosensible para fabricar diversas arquitecturas de electrodos neuronales. \u003ci\u003eFrontiers in Neuroengineering\u003c\/i\u003e, \u003ci\u003e5\u003c\/i\u003e. \u003ca href=\"http:\/\/doi.org\/10.3389\/fneng.2012.00011\"\u003ehttp:\/\/doi.org\/10.3389\/fneng.2012.00011\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eOhnami, S., Kato, A., Ogawa, K., Shinohara, S., Ono, H., \u0026amp; Tanabe, M. (2012). Efectos del milnaciprán, un inhibidor de la recaptación de 5-HT y noradrenalina, sobre los potenciales de campo evocados por fibras C en la potenciación a largo plazo espinal y el dolor neuropático. \u003ci\u003eBritish Journal of Pharmacology\u003c\/i\u003e, \u003ci\u003e167\u003c\/i\u003e(3), 537–47. \u003ca href=\"http:\/\/doi.org\/10.1111\/j.1476-5381.2012.02007.x\"\u003ehttp:\/\/doi.org\/10.1111\/j.1476-5381.2012.02007.x\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eRazy-Krajka, F., Brown, E. R., Horie, T., Callebert, J., Sasakura, Y., Joly, J.-S., … Vernier, P. (2012). Modulación monoaminérgica de la fotorecepción en ascidias: evidencia de un territorio proto-hipotálamo-retiniano. \u003ci\u003eBMC Biology\u003c\/i\u003e, \u003ci\u003e10\u003c\/i\u003e(1), 45. \u003ca href=\"http:\/\/doi.org\/10.1186\/1741-7007-10-45\"\u003ehttp:\/\/doi.org\/10.1186\/1741-7007-10-45\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eHu, W., Bi, Y., Zhang, K., Meng, F., \u0026amp; Zhang, J. (2011). La estimulación eléctrica de alta frecuencia en el núcleo accumbens de ratas tratadas con morfina suprime el disparo neuronal en regiones cerebrales relacionadas con la recompensa. \u003ci\u003eMedical Science Monitor : International Medical Journal of Experimental and Clinical Research\u003c\/i\u003e, \u003ci\u003e17\u003c\/i\u003e(6), BR153-60. Recuperado de \u003ca href=\"https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC3539543\" rel=\"noopener\" target=\"_blank\"\u003ehttps:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC3539543\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKim, J.-E., \u0026amp; Kang, T.-C. (2011). El complejo receptor P2X7–pannexina-1 disminuye la susceptibilidad a convulsiones mediada por receptores muscarínicos de acetilcolina en ratones. \u003ci\u003eJournal of Clinical Investigation\u003c\/i\u003e, \u003ci\u003e121\u003c\/i\u003e(5), 2037–2047. \u003ca href=\"http:\/\/doi.org\/10.1172\/JCI44818\"\u003ehttp:\/\/doi.org\/10.1172\/JCI44818\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKim, J.-E., \u0026amp; Kang, T.-C. (2011). El complejo receptor P2X7-pannexina-1 disminuye la susceptibilidad a convulsiones mediada por receptores muscarínicos de acetilcolina en ratones. \u003ci\u003eThe Journal of Clinical Investigation\u003c\/i\u003e, \u003ci\u003e121\u003c\/i\u003e(5), 2037–47. \u003ca href=\"http:\/\/doi.org\/10.1172\/JCI44818\"\u003ehttp:\/\/doi.org\/10.1172\/JCI44818\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eSchwarz, D., Bloom, D., Castro, R., Pagán, O. R., \u0026amp; Jiménez-Rivera, C. A. (2011). El partenólido bloquea el efecto de la cocaína sobre la actividad de disparo espontáneo de neuronas dopaminérgicas en el área tegmental ventral. \u003ci\u003eCurrent Neuropharmacology\u003c\/i\u003e, \u003ci\u003e9\u003c\/i\u003e(1), 17–20. \u003ca href=\"http:\/\/doi.org\/10.2174\/157015911795017010\"\u003ehttp:\/\/doi.org\/10.2174\/157015911795017010\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eBedi, S. S., Yang, Q., Crook, R. J., Du, J., Wu, Z., Fishman, H. M., … Walters, E. T. (2010). La actividad espontánea crónica generada en los somas de nociceptores primarios está asociada con comportamientos relacionados con el dolor tras una lesión de la médula espinal. \u003ci\u003eJournal of Neuroscience\u003c\/i\u003e, \u003ci\u003e30\u003c\/i\u003e(44), 14870–14882. \u003ca href=\"http:\/\/doi.org\/10.1523\/JNEUROSCI.2428-10.2010\"\u003ehttp:\/\/doi.org\/10.1523\/JNEUROSCI.2428-10.2010\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eGwak, Y. S., Unabia, G. C., \u0026amp; Hulsebosch, C. E. (2009). La activación de p-38alpha MAPK contribuye a la hiperexcitabilidad neuronal en regiones caudales alejadas de la lesión medular. \u003ci\u003eExperimental Neurology\u003c\/i\u003e, \u003ci\u003e220\u003c\/i\u003e(1), 154–61. \u003ca href=\"http:\/\/doi.org\/10.1016\/j.expneurol.2009.08.012\"\u003ehttp:\/\/doi.org\/10.1016\/j.expneurol.2009.08.012\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eGwak, Y. S., Crown, E. D., Unabia, G. C., \u0026amp; Hulsebosch, C. E. (2008). Propentofilina atenúa la alodinia, la activación glial y modula el tono GABAérgico tras lesión de la médula espinal en ratas. \u003ci\u003ePain\u003c\/i\u003e, \u003ci\u003e138\u003c\/i\u003e(2), 410–22. \u003ca href=\"http:\/\/doi.org\/10.1016\/j.pain.2008.01.021\"\u003ehttp:\/\/doi.org\/10.1016\/j.pain.2008.01.021\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eGreger, B., Kateb, B., Gruen, P., \u0026amp; Patterson, P. H. (2007). Dispositivo híbrido implantable crónicamente, cánula-electrodo, para evaluar los efectos de moléculas en señales electrofisiológicas en animales en libertad. \u003ci\u003eJournal of Neuroscience Methods\u003c\/i\u003e, \u003ci\u003e163\u003c\/i\u003e(2), 321–325. \u003ca href=\"http:\/\/doi.org\/10.1016\/j.jneumeth.2007.03.017\"\u003ehttp:\/\/doi.org\/10.1016\/j.jneumeth.2007.03.017\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eZhao, P., Waxman, S. G., \u0026amp; Hains, B. C. (2006). Expresión de canales de sodio en el núcleo ventral posterolateral del tálamo tras lesión del nervio periférico. \u003ci\u003eMolecular Pain\u003c\/i\u003e, \u003ci\u003e2\u003c\/i\u003e, 27. \u003ca href=\"http:\/\/doi.org\/10.1186\/1744-8069-2-27\"\u003ehttp:\/\/doi.org\/10.1186\/1744-8069-2-27\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eCharles, C. J., Jardine, D. L., Nicholls, M. G., \u0026amp; Richards, A. M. (2005). La adrenomedulina aumenta la actividad del nervio simpático cardíaco en ovejas conscientes normales. \u003ci\u003eThe Journal of Endocrinology\u003c\/i\u003e, \u003ci\u003e187\u003c\/i\u003e(2), 275–81. \u003ca href=\"http:\/\/doi.org\/10.1677\/joe.1.06337\"\u003ehttp:\/\/doi.org\/10.1677\/joe.1.06337\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKaminski, R. M., Marini, H., Kim, W.-J., \u0026amp; Rogawski, M. A. (2005). Actividad anticonvulsiva de androsterona y etiocholanolona. \u003ci\u003eEpilepsia\u003c\/i\u003e, \u003ci\u003e46\u003c\/i\u003e(6), 819–827. \u003ca href=\"http:\/\/doi.org\/10.1111\/j.1528-1167.2005.00705.x\"\u003ehttp:\/\/doi.org\/10.1111\/j.1528-1167.2005.00705.x\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eLi, X., Conklin, D., Pan, H.-L., \u0026amp; Eisenach, J. C. (2003). La modulación alostérica del receptor de adenosina reduce la hipersensibilidad tras inflamación periférica mediante un mecanismo central. \u003ci\u003eThe Journal of Pharmacology and Experimental Therapeutics\u003c\/i\u003e, \u003ci\u003e305\u003c\/i\u003e(3), 950–5. \u003ca href=\"http:\/\/doi.org\/10.1124\/jpet.102.047951\"\u003ehttp:\/\/doi.org\/10.1124\/jpet.102.047951\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eMasino, S. A. (2003). Comparación cuantitativa entre imagen funcional y disparo de unidad única en la corteza somatosensorial de rata. \u003ci\u003eJournal of Neurophysiology\u003c\/i\u003e, \u003ci\u003e89\u003c\/i\u003e(3), 1702–12. \u003ca href=\"http:\/\/doi.org\/10.1152\/jn.00860.2002\"\u003ehttp:\/\/doi.org\/10.1152\/jn.00860.2002\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eWichmann, T., Kliem, M. A., \u0026amp; DeLong, M. R. (2001). Efectos antiparkinsonianos y conductuales de la inactivación de la substantia nigra pars reticulata en primates hemiparkinsonianos. \u003ci\u003eExperimental Neurology\u003c\/i\u003e, \u003ci\u003e167\u003c\/i\u003e(2), 410–24. \u003ca href=\"http:\/\/doi.org\/10.1006\/exnr.2000.7572\"\u003ehttp:\/\/doi.org\/10.1006\/exnr.2000.7572\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42272907264090,"sku":"SYS-DAM80","price":3400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/dam80-angle_f93695dc-3aa8-43df-9023-a37909d3ab92.jpg?v=1766399620"}],"url":"https:\/\/wpiinc.com\/es\/collections\/electrophysiology.oembed","provider":"World Precision Instruments","version":"1.0","type":"link"}