{"title":"Consultar precio","description":"\u003ch1\u003eConsultar Precio\u003c\/h1\u003e","products":[{"product_id":"13338-ring-light-adapter-for-pzmiii-series","title":"Adaptador de Luz Anular para Serie PZMIII","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePermite montar la luz anular en el cuerpo del microscopio\u003c\/li\u003e\n\u003cli\u003ePerfecto para microscopios de la serie PZMIII\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42262684303450,"sku":"13338","price":34.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ring_light_adapt_49d28015201bf_78ffe2d0-b65b-4eb3-ad35-afee321fb09c.jpg?v=1766392782"},{"product_id":"13685-sp-series-pump-to-pump-linking-cable","title":"Cable de Enlace Bomba a Bomba Serie SP","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eConector A: Enchufe telefónico modular\u003c\/li\u003e\n\u003cli\u003eConector B: Enchufe telefónico modular\u003c\/li\u003e\n\u003cli\u003eCable: 7 pies (2.1 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42262688202842,"sku":"13685","price":11.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/13685_d4df522c-49b8-497d-880e-19844708b010.jpg?v=1766392845"},{"product_id":"var-8089-pure-iridium-metal-electrodes-profile-c","title":"Electrodos de metal puro de iridio perfil C","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRegistro de unidades múltiples y unidades simples\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTabla comparativa del perfil C de electrodos de metal de iridio puro\u003c\/strong\u003e \u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" class=\"sortable\" id=\"c1\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003cth style=\"background-color: #0081c2;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003eCódigo de pedido\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"background-color: #0081c2;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eLongitud\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"background-color: #0081c2;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eAislamiento\u003cbr\u003eGrosor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"background-color: #0081c2;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eEje\u003cbr\u003eDiámetro\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"background-color: #0081c2;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eNominal\u003cbr\u003eImpedancia\u003cbr\u003e±20%\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"background-color: #0081c2;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eConsejo\u003cbr\u003eDiámetro\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"background-color: #0081c2;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eUso típico\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eIRM23E05KT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50mm\u003c\/td\u003e\n\u003ctd\u003e3µ\u003c\/td\u003e\n\u003ctd\u003e0.180 mm\u003c\/td\u003e\n\u003ctd\u003e0.5 MΩ\u003c\/td\u003e\n\u003ctd\u003e2-3µ\u003c\/td\u003e\n\u003ctd\u003eRegistro y estimulación de unidades múltiples y ERP \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eIRM23E15KT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50mm\u003c\/td\u003e\n\u003ctd\u003e3µ\u003c\/td\u003e\n\u003ctd\u003e0.180 mm\u003c\/td\u003e\n\u003ctd\u003e1.5 MΩ\u003c\/td\u003e\n\u003ctd\u003e1-2µ\u003c\/td\u003e\n\u003ctd\u003eRegistro y estimulación de unidades simples y múltiples \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eIRM23E20KT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50mm\u003c\/td\u003e\n\u003ctd\u003e3µ\u003c\/td\u003e\n\u003ctd\u003e0.180 mm\u003c\/td\u003e\n\u003ctd\u003e2.0 MΩ\u003c\/td\u003e\n\u003ctd\u003e1-2µ\u003c\/td\u003e\n\u003ctd\u003eMayor selectividad y microestimulación \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eIRM23E30KT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50mm\u003c\/td\u003e\n\u003ctd\u003e3µ\u003c\/td\u003e\n\u003ctd\u003e0.180 mm\u003c\/td\u003e\n\u003ctd\u003e3.0 MΩ\u003c\/td\u003e\n\u003ctd\u003e1-2µ\u003c\/td\u003e\n\u003ctd\u003eMayor selectividad - células pequeñas \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUso típico\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRegistro y estimulación de unidades múltiples y unidades simples\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTubo de Kapton\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEl tubo de Kapton, indicado por “KT” en el número de parte, se extiende desde el conector hasta 5 mm de la punta, proporcionando rigidez y aislamiento adicional al eje del electrodo. Se recomiendan electrodos recubiertos con Kapton cuando el electrodo debe insertarse a través de una cánula para una penetración extra profunda.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/MetalMicroelectrodes_IS.pdf\" target=\"_self\"\u003eUso de microelectrodos metálicos recubiertos con parileno\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003ePreguntas frecuentes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Qué longitud necesito?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLa longitud total de cualquier sistema de electrodos se determina principalmente por la profundidad del tejido que se desea registrar o estimular y el sistema de microavance que se emplea. Las microsondas de tungsteno vienen en longitudes de 76 mm o 125 mm (no se ve 125 um en el sitio web de WPI) o se pueden pedir a medida en cualquier longitud menor a 5 pulgadas. El platino\/iridio típicamente viene en longitudes de dos pulgadas y el acero inoxidable en longitudes de 51 mm, pero cualquiera de los dos también puede especificarse en longitudes más cortas o en longitudes mayores usando acero inoxidable y tubos de poliamida. Debido al alto costo del iridio puro, siempre se monta en acero inoxidable y tubos de poliamida y típicamente mide 50 mm de largo.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Cuál es el grosor del aislamiento?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTodos los electrodos, excepto el microelectrodo de tungsteno de perfil Extra Fino de 3 pulgadas, que tiene un recubrimiento de 1 micrón de aislamiento de Parylene-C, tienen 3 micrones de Parylene-C. Se ha demostrado que este grosor funciona mejor para casi todos los perfiles de punta de electrodo que ofrecemos. Seleccionamos 3 micrones para proporcionar un perfil de punta suficientemente pequeño para acercarse a los elementos neuronales, facilitar la inserción del electrodo y minimizar la atenuación en electrodos de mayor impedancia. La atenuación de la señal puede ocurrir debido a un cortocircuito capacitivo al grabar con microelectrodos de mayor impedancia en estructuras profundas, por lo que puede ser necesario un aislamiento adicional en forma de microelectrodos KT o de poliimida de WPI. El perfil Extra Fino (por ejemplo, TM31C10) para los electrodos de tungsteno de 3 pulgadas ofrece una punta de microelectrodo extremadamente fina, excelente para grabar en estructuras celulares pequeñas y densamente agrupadas.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Qué impedancia o exposición de punta necesito?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eGracias a nuestro proceso único de fabricación y a las propiedades especiales del Parylene-C, podemos exponer cualquier microelectrodo con precisión y reproducibilidad microscópica. Cada microelectrodo se expone individualmente bajo un microscopio de alta potencia, se inspecciona y se caracteriza eléctricamente. Nuestros microelectrodos tienen un valor de impedancia más bajo para la misma exposición de la punta que otros electrodos disponibles comercialmente. Por lo tanto, se recomienda que quienes no hayan usado nuestros electrodos antes especifiquen un rango de impedancia para seleccionar el mejor valor de impedancia para su aplicación. Además, dado que hemos estado suministrando microelectrodos a investigadores durante más de 30 años, podemos ofrecer asesoramiento experto para seleccionar el mejor diseño de electrodo para su paradigma experimental. Por favor, contáctenos y proporcione información sobre los requisitos de su investigación. No hay cargo adicional por especificar un rango de valores de impedancia para cualquier caja de microelectrodos.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Qué perfil de punta es el mejor para mi aplicación?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOfrecemos una variedad de alternativas de puntas para aquellos que prefieren un perfil de electrodo especializado para su investigación. La selección de la punta puede proporcionar cambios sutiles pero importantes en el rendimiento del electrodo, como se describe a continuación. Se recomienda que los usuarios primerizos consideren experimentar con diferentes perfiles de punta para determinar cuál funciona mejor para sus protocolos de grabación o estimulación. A-Estándar Nuestro perfil de punta estándar presenta un punto afilado pero robusto que ofrece un rendimiento versátil y un equilibrio efectivo entre penetración y durabilidad. El perfil de punta más utilizado, recomendamos nuestra punta estándar para la mayoría de las aplicaciones de grabación neural, aunque también es eficaz para la mayoría de los protocolos de estimulación. Empleamos un método de exposición por arco que proporciona un rendimiento preciso y consistente, así como una amplia gama de impedancias disponibles. Aunque este método resulta en una pequeña variabilidad en la impedancia de un electrodo a otro, la mayoría de los investigadores lo encuentran muy aceptable para su aplicación. Para quienes necesitan una exposición de punta más exacta, ofrecemos un servicio de exposición láser por un pequeño costo adicional. Por favor, contáctenos si considera que este servicio es adecuado para usted. B-Despuntado Nuestros electrodos despuntados están diseñados para tener una punta más redondeada, con forma de bala. Para muchas aplicaciones, la punta despuntada puede ofrecer un rendimiento superior en estimulación, ya que su perfil más corto puede hacer que el electrodo actúe más como una fuente puntual y proporcione un mejor aislamiento. Muchos investigadores consideran que este perfil ofrece mayor selectividad que los perfiles de punta más afilados convencionales y es más apropiado para protocolos de estimulación de mayor intensidad. Algunos investigadores también han reportado observaciones de que el uso de puntas despuntadas conduce a menos casos de células perforadas. F-Extra fina Nuestro perfil de punta extra fina presenta un afilado significativamente más pronunciado, así como una capa de aislamiento más delgada. Este tipo de electrodo se usa comúnmente para preparaciones superficiales donde es necesario registrar poblaciones celulares pequeñas y densamente agrupadas, como las capas estriadas de las cortezas visual y auditiva. Debido a la naturaleza muy delicada de estas puntas, solo están disponibles en electrodos de tungsteno, con una longitud de 3 pulgadas (76 mm) y diámetros de eje de 0.003\" y 0.005\" (75 y 125 micrones). Para penetraciones mayores a 4 mm en las que la impedancia de la punta es superior a 1.5 MΩ, recomendamos especificar una capa adicional de tubo de poliamida para reducir el desvío capacitivo y aumentar la rigidez del electrodo. H-Tratado con calor Nuestros electrodos tratados con calor están destinados a aquellos investigadores que deben penetrar sus sondas a través de membranas resistentes, como la duramadre de mamíferos grandes. Al aplicar una fuente de calor cerca de la punta del electrodo bajo un microscopio, tenemos la capacidad de proporcionar un electrodo con una punta de taper más gradual que nuestro perfil estándar, al mismo tiempo que endurecemos el aislamiento de polímero cerca de la punta. Estas modificaciones permiten que el electrodo se empuje más fácilmente a través de membranas resistentes y con menor riesgo de daño en la punta y el aislamiento.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Problemas para leer la impedancia de sus microelectrodos metálicos?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003col\u003e\n\u003cli\u003eRevise su medidor de impedancia, tal vez esté midiendo los valores de impedancia a una frecuencia diferente a 1 kilohertz.\u003c\/li\u003e\n\u003cli\u003eVerifique si su medidor de impedancia no tiene un circuito de muestra y retención, en cuyo caso la impedancia se mide inmediatamente al presionar el botón de prueba y la impedancia no tiene oportunidad de estabilizarse.\u003c\/li\u003e\n\u003cli\u003ePor lo general, la impedancia disminuirá después de unos minutos de que el electrodo esté en la solución salina.\u003c\/li\u003e\n\u003cli\u003eA veces los electrodos pueden oxidarse aumentando la impedancia, en cuyo caso recomendamos aplicar entre -3 y -4.5 voltios a través del electrodo en solución salina para limpiar y desoxidar el electrodo.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Qué configuración de electrodo necesito?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eActualmente ofrecemos tres configuraciones diferentes de electrodos, aunque en el pasado hemos fabricado muchos diseños personalizados para clientes. Al observar cómo son nuestros números de parte para nuestras sondas, como se ve en la sección de Productos, notará que tienen un número de parte como WE30031.0A5. La parte 00 del número especifica la configuración de la microsonda. Electrodos monopolares - 00 implica que no hay montaje especial, con la sonda afilada aislada con Parylene-C, teniendo la longitud, ancho, perfil de punta e impedancia especificados en las tablas para ordenar sus electrodos. Electrodos con tubo de poliamida - PT que han sido montados en tubo de poliamida para aumentar la rigidez y proporcionar un grosor adicional de aislamiento. Este montaje se recomienda típicamente cuando electrodos de impedancia bastante alta deben penetrar capas más profundas del cerebro o la médula espinal. ST especifica nuestros electrodos bipolares o estereotrodes. Estos electrodos, cuando se ordenan con impedancias menores a 0.5 megaohmios, son excelentes para localizar campos de corriente de estimulación. Estereotrodes de impedancia más alta son excelentes para mejorar el aislamiento de elementos neuronales individuales mediante la grabación simultánea de múltiples unidades en dos microelectrodos muy cercanos. La separación de las puntas suele ser igual al diámetro del eje de uno de los electrodos usados para fabricar el estereotrodo. Se dispone de diferentes separaciones de punta bajo pedido.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Qué tipo de conectores se usan con nuestros electrodos?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLos conectores de pines 5482, 5483 están unidos al extremo distal de nuestros electrodos. Puede comprar estos conectores así como el conector hembra, M202, haciendo clic aquí y yendo a nuestra página de accesorios. Muchos usuarios prefieren usar nuestros electrodos sin ningún conector, lo cual está bien. Simplemente retiraremos los conectores para usted si lo solicita. No hay descuento por esto ya que los conectores se colocan al inicio de nuestro proceso de fabricación.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Cuáles son las exposiciones de punta para diferentes valores de impedancia del electrodo?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLas exposiciones de punta para perfiles de punta \"H\" con afilado por calor tienen aproximadamente un 15 a 20 por ciento MÁS exposición. Las exposiciones de punta para perfiles de punta \"B\" romos tienen aproximadamente un 15 a 20 por ciento MENOS exposición. Las exposiciones de punta para perfiles de punta \"F\" extra finos tienen aproximadamente un 10 a 15 por ciento MÁS exposición.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Problemas para leer la impedancia de sus microelectrodos metálicos?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003col\u003e\n\u003cli\u003eRevise su medidor de impedancia, tal vez esté midiendo los valores de impedancia a una frecuencia diferente a 1 kilohertz.\u003c\/li\u003e\n\u003cli\u003eVerifique si su medidor de impedancia no tiene un circuito de muestra y retención, en cuyo caso la impedancia se mide inmediatamente al presionar el botón de prueba y la impedancia no tiene oportunidad de estabilizarse.\u003c\/li\u003e\n\u003cli\u003ePor lo general, la impedancia disminuirá después de unos minutos de que el electrodo esté en la solución salina.\u003c\/li\u003e\n\u003cli\u003eA veces los electrodos pueden oxidarse aumentando la impedancia, en cuyo caso recomendamos aplicar entre -3 y -4.5 voltios a través del electrodo en solución salina para limpiar y desoxidar el electrodo.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"0,180 mm|3,0 MΩ","offer_id":42265682903130,"sku":"IRM23E30KT","price":672.0,"currency_code":"USD","in_stock":true},{"title":"0,180 mm|0,5 Mohm","offer_id":42265682935898,"sku":"IRM23E05KT","price":672.0,"currency_code":"USD","in_stock":true},{"title":"0,180 mm|1,5 Mohm","offer_id":42265682968666,"sku":"IRM23E15KT","price":672.0,"currency_code":"USD","in_stock":true},{"title":"0,180 mm|2,0 Mohm","offer_id":42265683001434,"sku":"IRM23E20KT","price":672.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/monopolar-wpolyimide-tubing_3_77084ad7-6d43-48f7-8584-9dad2b1ae51a.png?v=1766393478"},{"product_id":"500828-stage-micrometer-1mm-scale-200-div-at-10um","title":"Regla micrómetro de escala lineal 1mm\/0.01mm","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003ePortaobjetos de 1X3\" con objetivo lineal de 1mm grabado en el vidrio hasta marcas de 10μm\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"font-size: 12pt; line-height: 1.3em;\"\u003eLineal 1mm\/100\/0.01mm\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"font-size: 12pt; line-height: 1.3em;\"\u003eMarcas a 50 y 100μm\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"font-size: 12pt; line-height: 1.3em;\"\u003eAdecuado para microscopios verticales a 40X, 100X y 400X\u003c\/span\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable class=\"product-table\" width=\"100%\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eTipo\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eDescripción\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTipo de micrómetro\u003c\/td\u003e\r\n\u003ctd\u003eLínea\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDimensiones del micrómetro\u003c\/td\u003e\r\n\u003ctd\u003e75x25x1.5mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRango de escala\u003c\/td\u003e\r\n\u003ctd\u003eLineal 1mm\/100\/0.01mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTipo de fondo\u003c\/td\u003e\r\n\u003ctd\u003ePositivo\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMaterial\u003c\/td\u003e\r\n\u003ctd\u003eVidrio\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ePeso Neto\u003c\/td\u003e\r\n\u003ctd\u003e0.01kg (0.02lbs)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42265687883866,"sku":"500828","price":198.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/stage_micrometer_4c6d80660b9ec_dc3452e2-f211-44a9-9921-17982e5cfa03.jpg?v=1766393547"},{"product_id":"var-8088-pure-iridium-metal-electrodes-profile-a","title":"Electrodos de metal de iridio puro perfil A","description":"\u003c!-- section:details --\u003e\n\u003cul\u003e\r\n\u003cli\u003ePaquete de 5\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePerfil de electrodos de metal puro de iridio A Comparativa\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003ctable id=\"c1\" class=\"sortable\" style=\"height: 247px; width: 741px;\" border=\"0\"\u003e\r\n\u003cthead\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003cth style=\"background-color: #0081c2; width: 106.895px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003eCódigo de pedido\u003c\/span\u003e\u003c\/th\u003e\r\n\u003cth style=\"background-color: #0081c2; width: 29.1051px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eLargo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\r\n\u003cth style=\"background-color: #0081c2; width: 81px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eAislamiento\u003cbr\u003eGrosor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\r\n\u003cth style=\"background-color: #0081c2; width: 73px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eCaña\u003cbr\u003eDiámetro\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\r\n\u003cth style=\"background-color: #0081c2; width: 88px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eNominal\u003cbr\u003eImpedancia\u003cbr\u003e±20%\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\r\n\u003cth style=\"background-color: #0081c2; width: 73px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eConsejo\u003cbr\u003eDiámetro\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\r\n\u003cth style=\"background-color: #0081c2; width: 244px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eUso típico\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/thead\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"width: 106.895px;\"\u003e\u003cstrong\u003eIRM23E01\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd style=\"width: 29.1051px;\"\u003e50 mm\u003c\/td\u003e\r\n\u003ctd style=\"width: 81px;\"\u003e3µ\u003c\/td\u003e\r\n\u003ctd style=\"width: 73px;\"\u003e0,106 mm\u003c\/td\u003e\r\n\u003ctd style=\"width: 88px;\"\u003e0,1 MΩ\u003c\/td\u003e\r\n\u003ctd style=\"width: 73px;\"\u003e2-3µ\u003c\/td\u003e\r\n\u003ctd style=\"width: 244px;\"\u003eRegistro y estimulación de unidades múltiples y ERP\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd style=\"width: 106.895px;\"\u003e\u003cstrong\u003eIRM23E10\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd style=\"width: 29.1051px;\"\u003e50 mm\u003c\/td\u003e\r\n\u003ctd style=\"width: 81px;\"\u003e3µ\u003c\/td\u003e\r\n\u003ctd style=\"width: 73px;\"\u003e0,106 mm\u003c\/td\u003e\r\n\u003ctd style=\"width: 88px;\"\u003e1,0 MΩ\u003c\/td\u003e\r\n\u003ctd style=\"width: 73px;\"\u003e1-2µ\u003c\/td\u003e\r\n\u003ctd style=\"width: 244px;\"\u003eRegistro y estimulación de unidades simples y múltiples\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"width: 106.895px;\"\u003e\u003cstrong\u003eIRM23E15\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd style=\"width: 29.1051px;\"\u003e50 mm\u003c\/td\u003e\r\n\u003ctd style=\"width: 81px;\"\u003e3µ\u003c\/td\u003e\r\n\u003ctd style=\"width: 73px;\"\u003e0,106 mm\u003c\/td\u003e\r\n\u003ctd style=\"width: 88px;\"\u003e1,5 MΩ\u003c\/td\u003e\r\n\u003ctd style=\"width: 73px;\"\u003e1-2µ\u003c\/td\u003e\r\n\u003ctd style=\"width: 244px;\"\u003eRegistro y estimulación de unidades simples y múltiples\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd style=\"width: 106.895px;\"\u003e\u003cstrong\u003eIRM23E25\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd style=\"width: 29.1051px;\"\u003e50 mm\u003c\/td\u003e\r\n\u003ctd style=\"width: 81px;\"\u003e3µ\u003c\/td\u003e\r\n\u003ctd style=\"width: 73px;\"\u003e0,106 mm\u003c\/td\u003e\r\n\u003ctd style=\"width: 88px;\"\u003e2,5 MΩ\u003c\/td\u003e\r\n\u003ctd style=\"width: 73px;\"\u003e1-2µ\u003c\/td\u003e\r\n\u003ctd style=\"width: 244px;\"\u003eMayor selectividad - células pequeñas\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"width: 106.895px;\"\u003e\u003cstrong\u003eIRM23E30\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd style=\"width: 29.1051px;\"\u003e50 mm\u003c\/td\u003e\r\n\u003ctd style=\"width: 81px;\"\u003e3µ\u003c\/td\u003e\r\n\u003ctd style=\"width: 73px;\"\u003e0,106 mm\u003c\/td\u003e\r\n\u003ctd style=\"width: 88px;\"\u003e3,0 MΩ\u003c\/td\u003e\r\n\u003ctd style=\"width: 73px;\"\u003e1-2µ\u003c\/td\u003e\r\n\u003ctd style=\"width: 244px;\"\u003eMayor selectividad - células pequeñas\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cdiv\u003e \u003c\/div\u003e\r\n\u003cp\u003e\u003cstrong\u003eUso típico\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eRegistro y estimulación de unidades múltiples y unidades simples\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eTubo de Kapton\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eEl tubo de Kapton, indicado por “KT” en el número de parte, se extiende desde el conector hasta 5 mm antes de la punta, proporcionando rigidez y aislamiento adicional al eje del electrodo. Se recomiendan electrodos recubiertos con Kapton cuando el electrodo debe insertarse a través de una cánula para una penetración extra profunda.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/MetalMicroelectrodes_IS.pdf\" target=\"_self\"\u003eUso de microelectrodos metálicos recubiertos con parileno\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003ch2\u003ePreguntas frecuentes\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Qué longitud necesito?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eLa longitud total de cualquier sistema de electrodos se determina principalmente por la profundidad del tejido que se desea registrar o estimular y el sistema de microposicionamiento que se emplea. Las microsondas de tungsteno vienen en longitudes de 76 mm o 125 mm (no se ve 125 um en el sitio web de WPI) o se pueden pedir a medida en cualquier longitud menor a 5 pulgadas. El platino\/iridio típicamente viene en longitudes de dos pulgadas y el acero inoxidable en longitudes de 51 mm, pero cualquiera de los dos también puede especificarse en longitudes más cortas o en longitudes mayores usando acero inoxidable y tubos de poliamida. Debido al alto costo del iridio puro, siempre se monta en tubos de acero inoxidable y poliamida y típicamente mide 50 mm de largo.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Cuál es el grosor del aislamiento?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eTodos los electrodos, excepto el microelectrodo de tungsteno perfil Extra Fino de 3 pulgadas, que tiene un recubrimiento de 1 micrón de aislamiento de Parylene-C, tienen 3 micrones de Parylene-C. Se ha demostrado que este grosor funciona mejor para casi todos los perfiles de punta de electrodo que ofrecemos. Seleccionamos 3 micrones para proporcionar un perfil de punta suficientemente pequeño para acercarse a los elementos neuronales, facilitar la inserción del electrodo y minimizar la atenuación en electrodos de mayor impedancia. La atenuación de la señal puede ocurrir como resultado de un cortocircuito capacitivo al grabar con microelectrodos de mayor impedancia en estructuras profundas, por lo que puede ser necesario un aislamiento adicional en forma de los microelectrodos KT y de poliimida de WPI. El perfil Extra Fino (por ejemplo, TM31C10) para los electrodos de tungsteno de 3 pulgadas ofrece una punta de microelectrodo extremadamente fina, excelente para grabar en estructuras celulares pequeñas y densamente agrupadas.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Qué impedancia o exposición de punta necesito?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eDebido a nuestro proceso único de fabricación y las propiedades especiales del Parylene-C, podemos exponer cualquier microelectrodo con precisión y reproducibilidad microscópica. Cada microelectrodo se expone individualmente bajo un microscopio de alta potencia, se inspecciona y se caracteriza eléctricamente. Nuestros microelectrodos tienen un valor de impedancia más bajo para la misma exposición de la punta que otros electrodos disponibles comercialmente. Por lo tanto, se recomienda que quienes no hayan usado nuestros electrodos antes especifiquen un rango de impedancia para seleccionar el mejor valor de impedancia para su aplicación. Además, dado que hemos estado suministrando microelectrodos a investigadores durante más de 30 años, podemos ofrecer asesoramiento experto para seleccionar el mejor diseño de electrodo para su paradigma experimental. Por favor, contáctenos y proporcione información sobre los requisitos de su investigador. No hay cargo adicional por especificar un rango de valores de impedancia para cualquier caja de microelectrodos.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Qué perfil de punta es el mejor para mi aplicación?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eOfrecemos una variedad de alternativas de punta para aquellos que prefieren un perfil de electrodo especializado para su investigación. La selección de la punta puede proporcionar cambios sutiles pero importantes en el rendimiento del electrodo, como se describe a continuación. Se recomienda que los usuarios primerizos consideren experimentar con diferentes perfiles de punta para determinar cuál funciona mejor para sus protocolos de registro o estimulación. A-Estándar Nuestro perfil de punta estándar presenta un punto afilado pero robusto que ofrece un rendimiento versátil y un equilibrio efectivo entre penetración y durabilidad. El perfil de punta más utilizado, recomendamos nuestra punta estándar para la mayoría de las aplicaciones de registro neural, aunque también es eficaz para la mayoría de los protocolos de estimulación. Empleamos un método de exposición en arco que proporciona un rendimiento preciso y consistente, así como una amplia gama de impedancias disponibles. Aunque este método resulta en una pequeña variabilidad en la impedancia de un electrodo a otro, la mayoría de los investigadores lo encuentran muy aceptable para su aplicación. Para quienes necesitan una exposición de punta más exacta, ofrecemos un servicio de exposición láser por un pequeño costo adicional. Por favor contáctenos si considera que este servicio es adecuado para usted. B-Despuntado Nuestros electrodos despuntados están diseñados para tener una punta más redondeada, con forma de bala. Para muchas aplicaciones, la punta despuntada puede ofrecer un rendimiento superior en estimulación, ya que su perfil más corto puede hacer que el electrodo actúe más como una fuente puntual y proporcione un mejor aislamiento. Muchos investigadores consideran que este perfil ofrece mayor selectividad que los perfiles convencionales de punta más afilada y es más apropiado para protocolos de estimulación de mayor intensidad. Algunos investigadores también han reportado observaciones de que el uso de puntas despuntadas conduce a menos ocurrencias de células perforadas. F-Extra fina Nuestro perfil de punta extra fina presenta un afilado significativamente más pronunciado, así como una capa de aislamiento más delgada. Este tipo de electrodo se usa comúnmente para preparaciones superficiales donde es necesario registrar poblaciones celulares pequeñas y densamente agrupadas, como las capas estriadas de las cortezas visual y auditiva. Debido a la naturaleza muy delicada de estas puntas, solo están disponibles en electrodos de tungsteno, con una longitud de 3 pulgadas (76 mm) y diámetros de eje de 0.003\" y 0.005\" (75 y 125 micrones). Para penetraciones mayores a 4 mm en las que la impedancia de la punta es mayor a 1.5 MΩ, recomendamos especificar una capa adicional de tubo de poliamida para reducir el desvío capacitivo y aumentar la rigidez del electrodo. H-Tratado con calor Nuestros electrodos tratados con calor están destinados a aquellos investigadores que deben penetrar sus sondas a través de membranas resistentes, como la duramadre de mamíferos grandes. Al aplicar una fuente de calor cerca de la punta del electrodo bajo un microscopio, tenemos la capacidad de proporcionar un electrodo con una punta de afilado más gradual que nuestro perfil estándar, además de endurecer el aislamiento de polímero cerca de la punta. Estas modificaciones permiten que el electrodo se empuje más fácilmente a través de membranas resistentes y con menor riesgo de daño en la punta y el aislamiento.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Problemas para leer la impedancia de sus microelectrodos metálicos?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003col\u003e\r\n\u003cli\u003eRevise su medidor de impedancia, tal vez esté midiendo los valores de impedancia a una frecuencia diferente a 1 kilohercio.\u003c\/li\u003e\r\n\u003cli\u003eVerifique si su medidor de impedancia no tiene un circuito de muestra y retención, en cuyo caso la impedancia se mide inmediatamente al presionar el botón de prueba y la impedancia no tiene oportunidad de estabilizarse.\u003c\/li\u003e\r\n\u003cli\u003eNormalmente la impedancia disminuirá después de unos minutos de que el electrodo esté en la solución salina.\u003c\/li\u003e\r\n\u003cli\u003eA veces los electrodos pueden oxidarse aumentando la impedancia, en cuyo caso recomendamos aplicar entre -3 y -4.5 voltios a través del electrodo en solución salina para limpiar y desoxidar el electrodo.\u003c\/li\u003e\r\n\u003c\/ol\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Qué configuración de electrodo necesito?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eActualmente ofrecemos tres configuraciones diferentes de electrodos, aunque en el pasado hemos fabricado muchos diseños personalizados para clientes. Al observar cómo son nuestros números de parte para nuestras sondas, como se ve en la sección de Productos, notará que tienen un número de parte como WE30031.0A5. La parte 00 del número de parte especifica la configuración del microelectrodo. Electrodos monopolares - 00 implica que no hay montaje especial, con la sonda afilada aislada con Parylene-C, teniendo la longitud, ancho, perfil de punta e impedancia según lo especificado en las tablas para ordenar sus electrodos. Electrodos con tubo de poliamida - PT que han sido montados en tubo de poliamida para aumentar la rigidez y proporcionar un grosor adicional de aislamiento. Este montaje se recomienda típicamente cuando electrodos de impedancia bastante alta deben penetrar capas más profundas del cerebro o médula espinal. ST especifica nuestros electrodos bipolares o estereotrodes. Estos electrodos, cuando se ordenan con impedancias menores a 0.5 megaohmios, son excelentes para localizar campos de corriente de estimulación. Estereotrodes de impedancia más alta son excelentes para mejorar el aislamiento de elementos neuronales individuales mediante la grabación simultánea de múltiples unidades en dos microelectrodos muy cercanos. La separación de las puntas suele ser igual al diámetro del eje de uno de los electrodos usados para fabricar el estereotrodo. Se dispone de diferentes separaciones de punta bajo pedido.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Qué tipo de conectores se usan con nuestros electrodos?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eLos conectores de pines 5482, 5483 están unidos al extremo distal de nuestros electrodos. Puede comprar estos conectores así como el conector hembra, M202, haciendo clic aquí y yendo a nuestra página de accesorios. Muchos usuarios prefieren usar nuestros electrodos sin ningún conector, lo cual está bien. Simplemente retiraremos los conectores por usted si lo solicita. No hay descuento por esto ya que los conectores se colocan al inicio de nuestro proceso de fabricación.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Cuáles son las exposiciones de punta para diferentes valores de impedancia del electrodo?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eLas exposiciones de punta para perfiles de punta \"H\" con afilado por calor tienen aproximadamente un 15 a 20 por ciento MÁS exposición. Las exposiciones de punta para perfiles de punta \"B\" romos tienen aproximadamente un 15 a 20 por ciento MENOS exposición. Las exposiciones de punta para perfiles de punta \"F\" extra finos tienen aproximadamente un 10 a 15 por ciento MÁS exposición.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Problemas para leer la impedancia de sus microelectrodos metálicos?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003col\u003e\r\n\u003cli\u003eRevise su medidor de impedancia, tal vez esté midiendo los valores de impedancia a una frecuencia diferente a 1 kilohercio.\u003c\/li\u003e\r\n\u003cli\u003eVerifique si su medidor de impedancia no tiene un circuito de muestra y retención, en cuyo caso la impedancia se mide inmediatamente al presionar el botón de prueba y la impedancia no tiene oportunidad de estabilizarse.\u003c\/li\u003e\r\n\u003cli\u003eNormalmente la impedancia disminuirá después de unos minutos de que el electrodo esté en la solución salina.\u003c\/li\u003e\r\n\u003cli\u003eA veces los electrodos pueden oxidarse aumentando la impedancia, en cuyo caso recomendamos aplicar entre -3 y -4.5 voltios a través del electrodo en solución salina para limpiar y desoxidar el electrodo.\u003c\/li\u003e\r\n\u003c\/ol\u003e\r\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"0,106 mm|1,0 MΩ","offer_id":42265701679194,"sku":"IRM23E10","price":609.0,"currency_code":"USD","in_stock":true},{"title":"0,106 mm|1,5 Mohm","offer_id":42265701711962,"sku":"IRM23E15","price":609.0,"currency_code":"USD","in_stock":true},{"title":"0,106 mm|2,5 Mohm","offer_id":42265701744730,"sku":"IRM23E25","price":609.0,"currency_code":"USD","in_stock":true},{"title":"0,106 mm|0,1 MOhm","offer_id":42265701777498,"sku":"IRM23E01","price":609.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/monopolar-electrodes-wpi_3_1_1_5_0ea64e69-c95e-4c27-b0b0-39dc7c67968d.jpg?v=1766393637"},{"product_id":"var-8271-semi-micro-concentric-bipolar-electrodes-with-extension-rhodes-style-tip","title":"Electrodos bipolares concéntricos semi micro con extensión, punta estilo Rhodes","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eElectrodos bipolares semicónicos microconcentrados con extensión\u003c\/li\u003e\n\u003cli\u003eElija acero inoxidable o platino iridio\u003c\/li\u003e\n\u003cli\u003e411 x 140 x 250 µm, vástago de 10 mm, extensión de 50 mm\u003c\/li\u003e\n\u003cli\u003ePaquete de 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eLos electrodos bipolares concéntricos, diseñados para grabación y estimulación neurológica, son ideales para aplicaciones agudas. El tubo externo de acero inoxidable (E) proporciona soporte para una colocación y manipulación precisas durante la investigación aguda.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCantidad\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePaquete de 3\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/SSM04RC100-tip_med_d0d7ddde-5a2b-4c00-8bcc-754e551b6878.jpg?v=1765943652\" alt=\"punta rhodes\" width=\"500\" height=\"220\"\u003e\u003c\/p\u003e\n\u003ch2\u003eOpciones \u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #0081c2;\" bgcolor=\"#e4e4e4\"\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eCódigo de pedido\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eTipo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eNúcleo metálico  \u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eLongitud (s) \u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eDiámetro exterior total de la\u003cbr\u003esonda (z)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eDiámetro exterior  \u003cbr\u003emanga interior (x)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eExtensión (E)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e4e4e4\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSSM04RC100\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSemiconcéntrico micro con extensión \u003c\/td\u003e\n\u003ctd\u003eAcero inoxidable \u003c\/td\u003e\n\u003ctd\u003e0.4” (10 mm)  \u003c\/td\u003e\n\u003ctd\u003eaislado (411 µm)\u003c\/td\u003e\n\u003ctd\u003e140 µm \u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePTM04RC100\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSemiconcéntrico micro con extensión  \u003c\/td\u003e\n\u003ctd\u003ePlatino iridio\u003c\/td\u003e\n\u003ctd\u003e0.4” (10 mm) \u003c\/td\u003e\n\u003ctd\u003eaislado (411 µm)\u003c\/td\u003e\n\u003ctd\u003e140 µm\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e *Todos tienen un eje exterior de acero inoxidable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/MetalMicroelectrodes_IS.pdf\" target=\"_self\"\u003eUso de microelectrodos metálicos recubiertos de parileno\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003ePreguntas frecuentes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Qué longitud necesito?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLa longitud total de cualquier sistema de electrodos se determina principalmente por la profundidad del tejido que se desea grabar o estimular y el sistema de microavance empleado. Las microsondas de tungsteno vienen en longitudes de 76 mm o 125 mm (no se ve 125 µm en el sitio web de WPI) o pueden pedirse a medida en cualquier longitud menor a 5 pulgadas. El platino\/iridio suele venir en longitudes de dos pulgadas y el acero inoxidable en longitudes de 51 mm, pero cualquiera de ellos también puede especificarse en longitudes más cortas o más largas usando tubos de acero inoxidable y poliamida. Debido al alto costo del iridio puro, siempre se monta en tubos de acero inoxidable y poliamida y típicamente mide 50 mm de largo.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Cuál es el grosor del aislamiento?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTodos los electrodos, excepto la microsonda de tungsteno Extra Fina de 3 pulgadas con perfil F, que tiene un recubrimiento de 1 micrón de aislamiento de Parylene-C, tienen 3 micrones de Parylene-C. Se ha demostrado que este grosor funciona mejor para casi todos los perfiles de punta de electrodos que ofrecemos. Seleccionamos 3 micrones para proporcionar un perfil de punta suficientemente pequeño para acercarse a los elementos neuronales, facilitar la inserción del electrodo y minimizar la atenuación en electrodos de mayor impedancia. La atenuación de la señal puede ocurrir debido a un cortocircuito capacitivo al grabar con microsondas de alta impedancia en estructuras profundas, por lo que puede ser necesario un aislamiento adicional en forma de las microsondas KT de WPI, de poliamida. El perfil Extra Fino (ej. TM31C10) para los electrodos de tungsteno de 3 pulgadas ofrece una punta de microsonda extremadamente fina, excelente para grabar en estructuras celulares pequeñas y densamente agrupadas.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Qué impedancia o exposición de punta necesito?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eGracias a nuestro proceso de fabricación único y las propiedades especiales del Parylene-C, podemos exponer cualquier microsonda con precisión y reproducibilidad microscópica. Cada microsonda se expone individualmente bajo un microscopio de alta potencia, se inspecciona y se caracteriza eléctricamente. Nuestras microsondas tienen un valor de impedancia más bajo para la misma exposición de punta que otros electrodos disponibles comercialmente. Por lo tanto, se recomienda que quienes no hayan usado nuestros electrodos antes especifiquen un rango de impedancia para seleccionar el mejor valor para su aplicación. Además, dado que hemos suministrado microsondas a investigadores durante más de 30 años, podemos ofrecer asesoría experta para seleccionar el mejor diseño de electrodo para su paradigma experimental. Por favor contáctenos y proporcione información sobre los requisitos de su investigación. No hay cargo adicional por especificar un rango de valores de impedancia para cualquier caja de microsondas.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Qué perfil de punta es mejor para mi aplicación?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOfrecemos una variedad de alternativas de punta para quienes prefieren un perfil especializado para su investigación. La selección de la punta puede proporcionar cambios sutiles pero importantes en el rendimiento del electrodo, como se describe a continuación. Se recomienda que los usuarios primerizos experimenten con diferentes perfiles para determinar cuál funciona mejor para sus protocolos de grabación o estimulación. A-Estándar Nuestro perfil estándar presenta una punta afilada pero robusta que ofrece un rendimiento versátil y un equilibrio efectivo entre penetración y durabilidad. Es el perfil de punta más utilizado; recomendamos nuestra punta estándar para la mayoría de las aplicaciones de grabación neural, aunque también es eficaz para la mayoría de los protocolos de estimulación. Empleamos un método de exposición por arco que proporciona un rendimiento preciso y consistente, así como un rango muy amplio de impedancias disponibles. Aunque este método resulta en una pequeña variabilidad de impedancia entre electrodos, la mayoría de los investigadores lo encuentran muy aceptable para su aplicación. Para quienes necesitan una exposición de punta más exacta, ofrecemos un servicio de exposición láser por un pequeño costo adicional. Por favor contáctenos si cree que este servicio es adecuado para usted. B-Despuntado Nuestros electrodos despuntados están diseñados para tener una punta más redondeada, en forma de bala. Para muchas aplicaciones, la punta despuntada puede ofrecer un mejor rendimiento en estimulación, ya que su perfil más corto puede hacer que el electrodo actúe más como una fuente puntual y proporcione mejor aislamiento. Muchos investigadores consideran que este perfil ofrece mayor selectividad que los perfiles de punta más afilados convencionales y es más adecuado para protocolos de estimulación de mayor intensidad. Algunos investigadores también han observado que el uso de puntas despuntadas reduce la frecuencia de células perforadas. F-Extra fino Nuestro perfil de punta extra fina presenta un afilado significativamente mayor y una capa de aislamiento más delgada. Este tipo de electrodo se usa comúnmente para preparaciones superficiales donde es necesario grabar de poblaciones celulares pequeñas y densamente agrupadas, como las capas estriadas de las cortezas visual y auditiva. Debido a la naturaleza muy delicada de estas puntas, solo están disponibles en electrodos de tungsteno, en longitud de 3 pulgadas (76 mm) y diámetros de vástago de 0.003\" y 0.005\" (75 y 125 micrones). Para penetraciones mayores a 4 mm en las que la impedancia de la punta es mayor a 1.5 MΩ, recomendamos especificar una capa adicional de tubo de poliamida para reducir el cortocircuito capacitivo y aumentar la rigidez del electrodo. H-Tratado térmicamente Nuestros electrodos tratados térmicamente están destinados a investigadores que deben penetrar sus sondas a través de membranas resistentes, como la duramadre de mamíferos grandes. Aplicando una fuente de calor cerca de la punta del electrodo bajo un microscopio, podemos proporcionar un electrodo con una punta de afilado más gradual que nuestro perfil estándar, además de endurecer el aislamiento de polímero cerca de la punta. Estas modificaciones permiten que el electrodo se inserte más fácilmente a través de membranas resistentes y con menor riesgo de daño en la punta y el aislamiento.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Problemas para leer la impedancia de sus microelectrodos metálicos?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003col\u003e\n\u003cli\u003eRevise su medidor de impedancia, tal vez esté midiendo a una frecuencia diferente a 1 kilohertz.\u003c\/li\u003e\n\u003cli\u003eVerifique si su medidor de impedancia no tiene un circuito de muestreo y retención, en cuyo caso la impedancia se mide inmediatamente al presionar el botón de prueba y no tiene tiempo para estabilizarse.\u003c\/li\u003e\n\u003cli\u003eGeneralmente la impedancia disminuye después de unos minutos de que el electrodo está en solución salina.\u003c\/li\u003e\n\u003cli\u003eA veces los electrodos pueden oxidarse aumentando la impedancia; en ese caso recomendamos aplicar entre -3 y -4.5 voltios al electrodo en solución salina para limpiarlo y desoxidar el electrodo.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Qué configuración de electrodo necesito?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eActualmente ofrecemos tres configuraciones diferentes de electrodos, aunque en el pasado hemos fabricado muchos diseños personalizados para clientes. Al observar nuestros números de parte para las sondas, como se ve en la sección de Productos, notará que tienen un número como WE30031.0A5. La parte 00 del número especifica la configuración de la microsonda. Electrodos monopolares - 00 Indica que no hay montaje especial, con la sonda afilada aislada con Parylene-C, con la longitud, ancho, perfil de punta e impedancia especificados en las tablas para ordenar sus electrodos. Tubo de poliamida - PT Electrodos montados en tubo de poliamida para aumentar la rigidez y proporcionar mayor grosor de aislamiento. Este montaje se recomienda típicamente cuando electrodos de impedancia bastante alta deben penetrar capas profundas del cerebro o médula espinal. ST Especifica nuestros electrodos bipolares o estereotrodes. Estos electrodos, cuando se piden con impedancias menores a 0.5 megaohmios, son excelentes para localizar campos de corriente de estimulación. Los estereotrodes de mayor impedancia son excelentes para mejorar el aislamiento de elementos neuronales individuales mediante la grabación simultánea de múltiples unidades en dos microelectrodos muy cercanos. La separación de las puntas suele ser igual al diámetro del vástago de uno de los electrodos usados para fabricar el estereotrodo. Se dispone de diferentes separaciones de punta bajo pedido.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Qué tipo de conectores se usan con nuestros electrodos?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLos conectores de pines 5482, 5483 se fijan al extremo distal de nuestros electrodos. Puede comprar estos conectores así como el conector hembra, M202, haciendo clic aquí y yendo a nuestra página de accesorios. Muchos usuarios prefieren usar nuestros electrodos sin ningún conector, lo cual está bien. Simplemente retiraremos los conectores si lo solicita. No hay descuento por esto ya que los conectores se fijan al inicio de nuestro proceso de fabricación.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Cuáles son las exposiciones de punta para diferentes valores de impedancia del electrodo?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLas exposiciones de punta para perfiles de punta con afilado térmico \"H\" tienen aproximadamente un 15 a 20 por ciento MÁS exposición. Las exposiciones de punta para perfiles de punta despuntados \"B\" tienen aproximadamente un 15 a 20 por ciento MENOS exposición. Las exposiciones de punta para perfiles de punta extra fina \"F\" tienen aproximadamente un 10 a 15 por ciento MÁS exposición.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Problemas para leer la impedancia de sus microelectrodos metálicos?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003col\u003e\n\u003cli\u003eRevise su medidor de impedancia, tal vez esté midiendo a una frecuencia diferente a 1 kilohertz.\u003c\/li\u003e\n\u003cli\u003eVerifique si su medidor de impedancia no tiene un circuito de muestreo y retención, en cuyo caso la impedancia se mide inmediatamente al presionar el botón de prueba y no tiene tiempo para estabilizarse.\u003c\/li\u003e\n\u003cli\u003eGeneralmente la impedancia disminuye después de unos minutos de que el electrodo está en solución salina.\u003c\/li\u003e\n\u003cli\u003eA veces los electrodos pueden oxidarse aumentando la impedancia; en ese caso recomendamos aplicar entre -3 y -4.5 voltios al electrodo en solución salina para limpiarlo y desoxidar el electrodo.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"Acero inoxidable","offer_id":42265715245146,"sku":"SSM04RC100","price":788.0,"currency_code":"USD","in_stock":true},{"title":"Platino iridio","offer_id":42265715277914,"sku":"PTM04RC100","price":1300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ssm04rc100_3_7a05169f-153a-442c-a540-9e12a534355a.png?v=1766393737"},{"product_id":"501369-wide-field-10x-eyepieces-pair","title":"Oculares PZMIII de campo amplio 10x (par)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOculares de campo amplio 10x para PZMIII\u003c\/li\u003e\n\u003cli\u003eOculares para microscopio, un par\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42265715966042,"sku":"501369","price":277.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/501369_951254b1-3048-48a9-807f-f2edb2a92591.png?v=1766393762"},{"product_id":"501370-wide-field-15x-eyepieces-pair","title":"Oculares PZMIII de campo amplio 15x para microscopio (par)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOculares para microscopio PZMIII\u003c\/li\u003e\n\u003cli\u003eUn par de oculares\u003c\/li\u003e\n\u003cli\u003eAumento de 15x\u003c\/li\u003e\n\u003cli\u003eCampo amplio\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42265717047386,"sku":"501370","price":286.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/501370_e58d1fb9-b118-4de1-b662-726a29b7f62a.png?v=1766393768"},{"product_id":"501371-wide-field-20x-eyepieces-pair","title":"Oculares PZMIII de campo amplio 20x para microscopio (par)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOculares para microscopio PZMIII\u003c\/li\u003e\n\u003cli\u003eUn par de oculares\u003c\/li\u003e\n\u003cli\u003eAumento de 20x\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42265718259802,"sku":"501371","price":286.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/501371_4d41cd3e-d0da-4a21-8ef4-9d9cfc0ae12c.jpg?v=1766393777"},{"product_id":"501372-wide-field-25x-eyepieces-pair","title":"Oculares PZMIII de campo amplio 25x para microscopio (par)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOculares para microscopio PZMIII\u003c\/li\u003e\n\u003cli\u003eUn par de oculares\u003c\/li\u003e\n\u003cli\u003eAumento de 25x\u003c\/li\u003e\n\u003cli\u003eCampo amplio\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42265719341146,"sku":"501372","price":277.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/501372_d7d6603c-ea24-425b-aa08-8c3f85ec7946.jpg?v=1766393784"},{"product_id":"501381-05x-c-mount-ccd-camera-coupler","title":"Acoplador de cámara CCD C-Mount 0.5x para microscopio PZMIII","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible con cámaras que tienen CCD de 0.5 pulgadas\u003c\/li\u003e\n\u003cli\u003ePZMTIII\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eConfiguraciones de Cámara a Microscopio\u003c\/h2\u003e\n\u003cp\u003eConsulte \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microscope-camera-chart.pdf\"\u003eTabla de Microscopio\/Cámara\u003c\/a\u003e en la pestaña de Manuales y Recursos para información sobre la compatibilidad entre Microscopios y Cámaras.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microscope-camera-chart.pdf\"\u003eTabla de Microscopio\/Cámara\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42265720455258,"sku":"501381","price":310.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/0.5x_c_mount_ccd_4f1ed0318fecd_22dec197-3e94-4ce7-904b-798b8d594774.jpg?v=1766393791"},{"product_id":"502004-boom-stand","title":"Soporte de Brazo para Microscopio","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eRequiere soporte de enfoque 502009 (se vende por separado)\u003c\/li\u003e\r\n\u003cli\u003e502004 Soporte Boom sin FM\u003c\/li\u003e\r\n\u003cli\u003ePoste vertical de 39 cm (15.1”)\u003c\/li\u003e\r\n\u003cli\u003eBase horizontal de 52 cm (21”) 285 x 260 x 32 (11 ¼” x 10 ¼”)\u003c\/li\u003e\r\n\u003cli\u003eRotación de barra horizontal 0, 90 y 45 grados\u003c\/li\u003e\r\n\u003cli\u003ePeso de envío 45 lb.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cstrong\u003eNOTA\u003c\/strong\u003e: El soporte de enfoque debe comprarse por separado\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/502004_IMs.pdf\" target=\"_self\"\u003eManual de instrucciones del soporte Boom\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42265791889498,"sku":"502004","price":550.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/502004-side_9541810b-937d-4afa-b830-c639430f4b78.jpg?v=1766394273"},{"product_id":"502005-ball-bearing-boom-stand","title":"Soporte de Brazo con Rodamientos para Microscopio","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eLa construcción de brazo doble con rodamientos de bolas aumenta la estabilidad y permite movimientos horizontales más suaves.\u003c\/li\u003e\r\n\u003cli\u003eLongitud del brazo es de 40 cm\u003c\/li\u003e\r\n\u003cli\u003eEl soporte de enfoque debe comprarse por separado\u003c\/li\u003e\r\n\u003cli\u003eRequiere soporte de enfoque 502009 \u003c\/li\u003e\r\n\u003cli\u003eLongitud de recorrido horizontal de 40 cm (16”)\u003c\/li\u003e\r\n\u003cli\u003ePoste vertical de 39 cm (15.1”)\u003c\/li\u003e\r\n\u003cli\u003econ extensión de 22.5 cm (8.8”) (solo 502005)\u003c\/li\u003e\r\n\u003cli\u003eBase 285 x 260 x 32 (11.25” x10.25”)\u003c\/li\u003e\r\n\u003cli\u003ePeso de envío 49 lb.\u003c\/li\u003e\r\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/502005_IMs.pdf\"\u003eManual de instrucciones del soporte de brazo con rodamientos de bolas 502005\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42265793265754,"sku":"502005","price":668.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ball_bearing_boo_4f1ed5a8d63a1_6454f738-9540-4b2a-80cb-9953f98a512f.jpg?v=1766394280"},{"product_id":"502006-boom-clamp-stand","title":"Soporte de Brazo con Abrazadera para Microscopio","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eSoporte con abrazadera de brazo pesado (requiere montaje de enfoque 502009)\u003c\/li\u003e\r\n\u003cli\u003ePara usar con la cabeza de microscopio PZMIII o PZMIV\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eDetalles\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eEntre la barra horizontal pequeña y el antebrazo ajustable\u003c\/li\u003e\r\n\u003cli\u003eEntre el antebrazo ajustable y la barra horizontal media\u003c\/li\u003e\r\n\u003cli\u003eEntre la barra horizontal media y el soporte de brazo \u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/502006-description_58ee2db5-85cf-421a-8f32-361bd22cebd7.jpg?v=1765943952\" alt=\"502006\"\u003e\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eRequisitos\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eRequiere montaje de enfoque 502009 (se vende por separado)\u003c\/li\u003e\r\n\u003cli\u003eSoporte con abrazadera de brazo sin montaje de enfoque\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ctable class=\"product-table\" style=\"height: 149px; width: 100%;\" width=\"100%\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"height: 18px;\"\u003e\r\n\u003ctd style=\"text-align: center; height: 18px;\"\u003e\u003cstrong\u003eTipo\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; height: 18px;\"\u003e\u003cstrong\u003eDescripción\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 18px;\"\u003e\r\n\u003ctd style=\"height: 18px;\"\u003ePoste vertical\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px;\"\u003e39 cm (15.1”)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 23px;\"\u003e\r\n\u003ctd style=\"height: 23px;\"\u003ePoste horizontal\u003c\/td\u003e\r\n\u003ctd style=\"height: 23px;\"\u003e52 cm (21”) \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 18px;\"\u003e\r\n\u003ctd style=\"height: 18px;\"\u003eBase\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px;\"\u003e285 x 260 x 32 mm (11.25” x 10.25”)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 18px;\"\u003e\r\n\u003ctd style=\"height: 18px;\"\u003eRango de articulación\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px;\"\u003e46 cm (18”)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 18px;\"\u003e\r\n\u003ctd style=\"height: 18px;\"\u003eLongitudes del brazo\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px;\"\u003eL-R 23, 40, 30 cm (9”, 16”, 12”)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 18px;\"\u003e\r\n\u003ctd style=\"height: 18px;\"\u003ePeso de envío\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px;\"\u003e46 lb.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/502006_IMs.pdf\"\u003e\u003cstrong\u003e502006\u003c\/strong\u003e Manual de instrucciones del soporte con abrazadera de brazo\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable style=\"height: 486px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eTipo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eDescripción\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003eTipo de soporte\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003eBrazo flexible\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 18px;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003eAltura del poste vertical\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003e384 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003eLongitud máxima extendida del poste vertical\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003e254 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 18px;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003eDiámetro del poste vertical\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003e37.2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003eTipo de adaptador cruzado\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003eAdaptador de doble orificio\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 18px;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003eLongitud total del brazo\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003e800 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003eLongitud de la barra horizontal media\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003e330 mm (13”)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 18px;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003eLongitud de la barra horizontal ajustable\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003e450 mm (17.72”)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003eLongitud de la barra horizontal corta\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003e170 mm (6.7”)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 18px;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003eÁngulo máximo de apertura en dirección vertical\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003e500 mm (19.7”)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003eOrificio de montaje en el extremo del brazo horizontal\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003eAdaptador final de 15.875 mm (0.625”)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 18px;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003eÁngulo de rotación horizontal\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003eRotación de 360º\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003eRadio máximo de revolución\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003e31.89” (810 mm)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 18px;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003eRadio mínimo de revolución\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003e13” (330 mm)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003eCarga máxima del brazo horizontal\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003e11.34 kg (25 lbs.)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 18px;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003eModo de desplazamiento del brazo horizontal en dirección horizontal\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003eManual\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003eModo de desplazamiento del brazo horizontal en dirección Z\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003eManual\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 18px;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003eTipo de base\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003eBase resistente\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003eForma de la base\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003eRectángulo\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 18px;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003eDimensiones de la base\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003e330 x 330 x 38 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003eTamaño del adaptador de montaje del soporte\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003eØ 22.2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 18px;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003eTratamiento de superficie\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003eElectrochapado negro\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003eMaterial\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003eMetal\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 18px;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003eColor\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003eNegro\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003ePeso\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003e43.8 kg (96.56 lbs.)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 18px;\"\u003e\r\n\u003ctd style=\"height: 18px; width: 351px;\"\u003eDimensiones\u003c\/td\u003e\r\n\u003ctd style=\"height: 18px; width: 291px;\"\u003e500 x 330 x 422 mm (19.7 x 13 x 16.6”)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42265797853274,"sku":"502006","price":923.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/boom_clamp_stand_4e9c74b822f85_18774c8e-656d-46de-99e2-83a2250ce39c.jpg?v=1766394289"},{"product_id":"502007-articulated-arm-and-table-clamp","title":"Soporte de Brazo Articulado con Abrazadera de Mesa para Microscopio","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eMontaje de mesa con brazo articulado sin soporte de enfoque\u003c\/li\u003e\r\n\u003cli\u003eRequiere soporte de enfoque 502009 (se vende por separado) para PZMIII\u003c\/li\u003e\r\n\u003cli\u003eNo recomendado para PZMIV\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetalles\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eEntre la barra horizontal pequeña y el antebrazo ajustable\u003c\/li\u003e\r\n\u003cli\u003eEntre el antebrazo ajustable y la barra horizontal media\u003c\/li\u003e\r\n\u003cli\u003eEntre la barra horizontal media y la abrazadera de mesa \u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/502007-description_0b0a45d0-b68b-4fc0-9dcf-6e95f43292a2.jpg?v=1765943963\" alt=\"502007\" width=\"700\" height=\"728\"\u003e\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/502007_IMs.pdf\"\u003e\u003cstrong\u003e502007 \u003c\/strong\u003e Manual de instrucciones del brazo articulado y abrazadera de mesa\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ctable class=\"product-table\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTipo\u003c\/td\u003e\r\n\u003ctd\u003eDescripciones\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTipo de soporte\u003c\/td\u003e\r\n\u003ctd\u003eBrazo flexible\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eLongitud total del brazo\u003c\/td\u003e\r\n\u003ctd\u003e800 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eLongitud de la barra horizontal media\u003c\/td\u003e\r\n\u003ctd\u003e330 mm (13”)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eLongitud de la barra horizontal ajustable\u003c\/td\u003e\r\n\u003ctd\u003e450 mm (17.72”)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eLongitud de la barra horizontal corta\u003c\/td\u003e\r\n\u003ctd\u003e170 mm (6.7”)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eÁngulo máximo de apertura en dirección vertical\u003c\/td\u003e\r\n\u003ctd\u003e500 mm (19.7”)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOrificio de montaje en el extremo del brazo horizontal\u003c\/td\u003e\r\n\u003ctd\u003eAdaptador final de 15.875 mm (0.625”)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eÁngulo de rotación horizontal\u003c\/td\u003e\r\n\u003ctd\u003eRotación 360º\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRadio máximo de revolución\u003c\/td\u003e\r\n\u003ctd\u003e31.89” (810 mm)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eRadio mínimo de revolución\u003c\/td\u003e\r\n\u003ctd\u003e13” (330 mm)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCarga máxima del brazo horizontal\u003c\/td\u003e\r\n\u003ctd\u003e9.5 kg (20.94 lbs.)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eModo de desplazamiento del brazo horizontal en dirección horizontal\u003c\/td\u003e\r\n\u003ctd\u003eManual\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eModo de desplazamiento del brazo horizontal en dirección Z\u003c\/td\u003e\r\n\u003ctd\u003eManual\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eTipo de base\u003c\/td\u003e\r\n\u003ctd\u003eAbrazadera\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eForma de la base\u003c\/td\u003e\r\n\u003ctd\u003eRectángulo\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eDiámetro del orificio de montaje de la base\u003c\/td\u003e\r\n\u003ctd\u003e22 mm (0.87”)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDimensiones de la base de la abrazadera\u003c\/td\u003e\r\n\u003ctd\u003e104 x 77 x 136 mm (4 x 3 x 4.5”)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eTamaño de apertura de la abrazadera\u003c\/td\u003e\r\n\u003ctd\u003e0–53 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTratamiento de superficie\u003c\/td\u003e\r\n\u003ctd\u003ePintura en spray\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eMaterial\u003c\/td\u003e\r\n\u003ctd\u003eMetal\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eColor\u003c\/td\u003e\r\n\u003ctd\u003eNegro\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003ePeso\u003c\/td\u003e\r\n\u003ctd\u003e5.63 kg (12.4 lbs.)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDimensiones\u003c\/td\u003e\r\n\u003ctd\u003e104 x 450 x 320 mm (4 x 17.7 x 12.6”)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42265799426138,"sku":"502007","price":465.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/articulated_arm__4a6090a42b310_b46320a1-5f8a-44f9-9a82-27ad51cb1a3c.jpg?v=1766394296"},{"product_id":"503051-manual-stage-for-pzmiii","title":"Etapa Manual para PZMIII","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSe monta en la abertura circular de la base PZMiii.\u003c\/li\u003e\n\u003cli\u003eDistancia de recorrido XY: 75x56mm\u003c\/li\u003e\n\u003cli\u003eTamaño del vidrio: 116x96mm\u003c\/li\u003e\n\u003cli\u003eDiámetro activo: 37.6mm\u003c\/li\u003e\n\u003cli\u003eDimensiones: 180x155x27mm\u003c\/li\u003e\n\u003cli\u003eCompatible solo con la base 503102\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42265871089754,"sku":"503051","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/503051_00f68691-b760-48ab-ab7a-f4b611e737ab.jpg?v=1766394495"},{"product_id":"503102-rectangular-base-post-stand-for-pzmiii-pzmiv","title":"Soporte de Poste con Base Rectangular para PZMIII\/PZMIV","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eSoporte de poste de 76 mm (PZMIII)\u003c\/li\u003e\r\n\u003cli\u003eTamaño de la base: 12.6×12.01×0.63\" (320×305×16 mm)\u003c\/li\u003e\r\n\u003cli\u003eSoporte para microscopio: 76 mm\u003c\/li\u003e\r\n\u003cli\u003eTamaño máximo desde el poste vertical hasta el frente de la base: 10.75\" (273 mm)\u003c\/li\u003e\r\n\u003cli\u003ePoste vertical: diámetro 1.26\" (32 mm), altura 12.01\" (305 mm)\u003c\/li\u003e\r\n\u003cli\u003ePoste de extensión: 5.9\" (150 mm)\u003c\/li\u003e\r\n\u003cli\u003ePlaca blanca y negra de 95 mm de diámetro\u003c\/li\u003e\r\n\u003cli\u003ePeso: 6.6 lbs, 3 kg\u003c\/li\u003e\r\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/503102_IMs.pdf\"\u003eManual de instrucciones del soporte de poste para microscopio\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42265890488410,"sku":"503102","price":386.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/rectangular_base_4a608619599bf_d4b07de1-c8e3-4aec-b29d-c0b81a4392e1.jpg?v=1766394605"},{"product_id":"var-8087-elgiloy-stainless-electrode-profile-c","title":"Electrodo Elgiloy-acero inoxidable perfil C","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003e\n\u003cstrong\u003eElgiloy\u003c\/strong\u003e es una aleación de acero inoxidable con un componente de cobalto-cromo. Se usa para electrodos monopolares en aplicaciones especiales y se encuentra frecuentemente en implantes dentales. Su biocompatibilidad es buena y es resistente a la corrosión.\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eElectrodo de Elgiloy\/Acero inoxidable\u003c\/li\u003e\r\n\u003cli\u003ePerfil C\u003c\/li\u003e\r\n\u003cli\u003eLongitud de 76 mm\u003c\/li\u003e\r\n\u003cli\u003eAislamiento de 3 µm\u003c\/li\u003e\r\n\u003cli\u003eDiámetro del eje de 0.61 mm\u003c\/li\u003e\r\n\u003cli\u003eDiámetro de punta de 1–2 µm\u003c\/li\u003e\r\n\u003cli\u003ePara estudios de cerebro profundo\u003c\/li\u003e\r\n\u003cli\u003ePaquete de 3\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ctable width=\"100%\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd style=\"width: 50%;\" colspan=\"2\"\u003e\r\n\u003ch2\u003eVENTAJAS\u003c\/h2\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd style=\"width: 10%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/good-recording-performance_902f85a0-f5b6-4fa9-90ae-e25637639b47.jpg?v=1765944594\" alt=\"Buen rendimiento de registro\" width=\"100\" height=\"100\"\u003e\u003c\/td\u003e\r\n\u003ctd style=\"width: 40%;\"\u003e\r\n\u003ch3\u003e\u003cspan style=\"color: #0081c2;\"\u003eBuen rendimiento de registro\u003c\/span\u003e\u003c\/h3\u003e\r\n\u003cp\u003eElgiloy es un metal versátil con buen rendimiento de registro en aplicaciones agudas y crónicas.\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd style=\"width: 10%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/prussian-blue-staining-techniques_a523facf-a098-48f1-9540-68dcbec04fd0.jpg?v=1765944601\" alt=\"Técnicas de tinción con azul de Prusia\" width=\"100\" height=\"100\"\u003e\u003c\/td\u003e\r\n\u003ctd style=\"width: 40%;\"\u003e\r\n\u003ch3\u003e\u003cspan style=\"color: #0081c2;\"\u003eTécnicas de tinción con azul de Prusia\u003c\/span\u003e\u003c\/h3\u003e\r\n\u003cp\u003eDado que Elgiloy contiene una pequeña cantidad de hierro, permite la identificación visual de los trayectos del electrodo cuando se usan técnicas de tinción con azul de Prusia.\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd style=\"width: 50%;\" colspan=\"2\"\u003e\r\n\u003ch3\u003e \u003c\/h3\u003e\r\n\u003ch2\u003eCONSIDERACIONES\u003c\/h2\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd style=\"width: 50%;\" colspan=\"2\"\u003e\r\n\u003ch3\u003e¿Realizará microestimulación?\u003c\/h3\u003e\r\n\u003cp\u003eSus pobres características de transferencia de carga e inestabilidad electroquímica durante la estimulación hacen que los electrodos de elgiloy sean inadecuados para microestimulación. Considere usar un electrodo de platino-iridio para esa aplicación.\u003c\/p\u003e\r\n\u003ch3\u003e¿Su aplicación implica implantación crónica?\u003c\/h3\u003e\r\n\u003cp\u003ePuede ocurrir corrosión o degradación del rendimiento cuando un electrodo de elgiloy se usa para implantación crónica o para ciertos protocolos de estimulación. Considere usar un electrodo de platino-iridio para esa aplicación.\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003ch2\u003e \u003c\/h2\u003e\r\n\u003ch2\u003eOpciones\u003c\/h2\u003e\r\n\u003cp\u003eTabla comparativa de perfil C Elgiloy\/Acero inoxidable\u003c\/p\u003e\r\n\u003ctable border=\"0\"\u003e\r\n\u003cthead\u003e\r\n\u003ctr bgcolor=\"e4e4e4\"\u003e\r\n\u003cth style=\"background-color: #0081c2;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eArtículo \u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\r\n\u003cth style=\"background-color: #0081c2;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eNominal\u003cbr\u003eImpedancia\u003cbr\u003e±20%\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/thead\u003e\r\n\u003ctbody\u003e\r\n\u003ctr bgcolor=\"e4e4e4\"\u003e\r\n\u003ctd\u003e\u003cstrong\u003eSSM123B10KT\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e1.0 M\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cstrong\u003eSSM123B20KT\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e2.0 M\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"e4e4e4\"\u003e\r\n\u003ctd\u003e\u003cstrong\u003eSSM123B05KT\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e0.5 M\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e  \u003c\/p\u003e\r\n\u003cp\u003e\u003ca href=\"\/es\/blog\/post\/metal-microelectrode-selection-guide\"\u003e\u003cstrong\u003eVer Guía de selección de microelectrodos metálicos\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/MetalMicroelectrodes_IS.pdf\" target=\"_self\"\u003eUso de microelectrodos metálicos recubiertos con parileno\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003ch2\u003ePreguntas frecuentes\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Qué longitud necesito?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eLa longitud total de cualquier sistema de electrodos se determina principalmente por la profundidad del tejido que se desea registrar o estimular y el sistema de microavance que se esté utilizando. Las microsondas de tungsteno vienen en longitudes de 76 mm o 125 mm (no se ve 125 um en el sitio web de WPI) o se pueden pedir a medida en cualquier longitud menor a 5 pulgadas. El platino\/iridio típicamente viene en longitudes de dos pulgadas y el acero inoxidable en longitudes de 51 mm, pero cualquiera de los dos también puede especificarse en longitudes más cortas o en longitudes mayores usando acero inoxidable y tubos de poliamida. Debido al alto costo del iridio puro, siempre se monta en acero inoxidable y tubos de poliamida y típicamente mide 50 mm de largo.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Cuál es el grosor del aislamiento?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eTodos los electrodos, excepto el microelectrodo de tungsteno perfil Extra Fino de 3 pulgadas, que tiene un recubrimiento de 1 micrón de aislamiento de Parylene-C, tienen 3 micrones de Parylene-C. Se ha demostrado que este grosor funciona mejor para casi todos los perfiles de punta de electrodo que ofrecemos. Seleccionamos 3 micrones para proporcionar un perfil de punta suficientemente pequeño para acercarse a los elementos neuronales, facilitar la inserción del electrodo y minimizar la atenuación en electrodos de mayor impedancia. La atenuación de la señal puede ocurrir como resultado de un cortocircuito capacitivo al grabar con microelectrodos de mayor impedancia en estructuras profundas, por lo que puede ser necesario un aislamiento adicional en forma de microelectrodos KT de WPI, de poliimida. El perfil Extra Fino (por ejemplo, TM31C10) para los electrodos de tungsteno de 3 pulgadas ofrece una punta de microelectrodo extremadamente fina, excelente para grabar en estructuras celulares pequeñas y densamente agrupadas.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Qué impedancia o exposición de punta necesito?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eDebido a nuestro proceso único de fabricación y las propiedades especiales del Parylene-C, podemos exponer cualquier microelectrodo con precisión y reproducibilidad microscópicas. Cada microelectrodo se expone individualmente bajo un microscopio de alta potencia, se inspecciona y se caracteriza eléctricamente. Nuestros microelectrodos tienen un valor de impedancia más bajo para la misma exposición de la punta que otros electrodos disponibles comercialmente. Por lo tanto, se recomienda que quienes no hayan usado nuestros electrodos antes especifiquen un rango de impedancia para seleccionar el mejor valor de impedancia para su aplicación. Además, dado que hemos estado suministrando microelectrodos a investigadores durante más de 30 años, podemos ofrecer asesoramiento experto para seleccionar el mejor diseño de electrodo para su paradigma experimental. Por favor, contáctenos y proporcione información sobre los requisitos de su investigador. No hay cargo adicional por especificar un rango de valores de impedancia para cualquier caja de microelectrodos.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Qué perfil de punta es el mejor para mi aplicación?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eOfrecemos una variedad de alternativas de punta diferentes para aquellos que prefieren un perfil de electrodo especializado para su investigación. La selección de la punta puede proporcionar cambios sutiles pero importantes en el rendimiento del electrodo, como se describe a continuación. Se recomienda que los usuarios primerizos consideren experimentar con diferentes perfiles de punta para determinar cuál funciona mejor para sus protocolos de grabación o estimulación. A-Estándar Nuestro perfil de punta estándar presenta un punto afilado pero robusto que ofrece un rendimiento versátil y un equilibrio efectivo entre penetración y durabilidad. El perfil de punta más utilizado, recomendamos nuestra punta estándar para la mayoría de las aplicaciones de grabación neural, aunque también es eficaz para la mayoría de los protocolos de estimulación. Empleamos un método de exposición en arco que proporciona un rendimiento preciso y consistente, así como una gama muy amplia de impedancias disponibles. Aunque este método resulta en una pequeña variabilidad en la impedancia de un electrodo a otro, la mayoría de los investigadores lo encuentran muy aceptable para su aplicación. Para aquellos que necesitan una exposición de punta más exacta, ofrecemos un servicio de exposición láser por un pequeño costo adicional. Por favor contáctenos si considera que este servicio es adecuado para usted. B-Despuntado Nuestros electrodos despuntados están diseñados para tener una punta más redondeada, con forma de bala. Para muchas aplicaciones, la punta despuntada puede ofrecer un rendimiento superior en estimulación, ya que su perfil más corto puede hacer que el electrodo actúe más como una fuente puntual y proporcione un mejor aislamiento. Muchos investigadores consideran que este perfil ofrece mayor selectividad que los perfiles de punta más afilados convencionales y es más apropiado para protocolos de estimulación de mayor intensidad. Algunos investigadores también han reportado observaciones de que el uso de puntas despuntadas conduce a menos ocurrencias de células perforadas. F-Extra fina Nuestro perfil de punta extra fina presenta un afilado significativamente más pronunciado, así como una capa de aislamiento más delgada. Este tipo de electrodo se usa comúnmente para preparaciones superficiales donde es necesario grabar de poblaciones celulares pequeñas y densamente agrupadas, como las capas estriadas de las cortezas visual y auditiva. Debido a la naturaleza muy delicada de estas puntas, solo están disponibles en electrodos de tungsteno, con una longitud de 3 pulgadas (76 mm) y diámetros de eje de 0.003\" y 0.005\" (75 y 125 micrones). Para penetraciones mayores a 4 mm en las que la impedancia de la punta es mayor a 1.5 MΩ, recomendamos especificar una capa adicional de tubo de poliamida para reducir el desvío capacitivo y aumentar la rigidez del electrodo. H-Tratado con calor Nuestros electrodos tratados con calor están destinados a aquellos investigadores que deben penetrar sus sondas a través de membranas resistentes, como la duramadre de mamíferos más grandes. Al aplicar una fuente de calor cerca de la punta del electrodo bajo un microscopio, tenemos la capacidad de proporcionar un electrodo con una punta de afilado más gradual que nuestro perfil estándar, al mismo tiempo que endurecemos el aislamiento de polímero cerca de la punta. Estas modificaciones permiten que el electrodo se empuje a través de membranas resistentes con mayor facilidad y con menos riesgo de daño en la punta y el aislamiento.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Problemas para leer la impedancia de sus microelectrodos metálicos?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003col\u003e\r\n\u003cli\u003eRevise su medidor de impedancia, tal vez esté midiendo los valores de impedancia a una frecuencia diferente a 1 kilohertz.\u003c\/li\u003e\r\n\u003cli\u003eVerifique si su medidor de impedancia no tiene un circuito de muestra y retención, en cuyo caso la impedancia se mide inmediatamente al presionar el botón de prueba y la impedancia no tiene oportunidad de estabilizarse.\u003c\/li\u003e\r\n\u003cli\u003eNormalmente la impedancia disminuirá después de unos minutos de que el electrodo esté en la solución salina.\u003c\/li\u003e\r\n\u003cli\u003eA veces los electrodos pueden oxidarse aumentando la impedancia, en cuyo caso recomendamos aplicar aproximadamente entre -3 y -4.5 voltios a través del electrodo en solución salina para limpiar y desoxidar el electrodo.\u003c\/li\u003e\r\n\u003c\/ol\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Qué configuración de electrodo necesito?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eActualmente ofrecemos tres configuraciones diferentes de electrodos, aunque en el pasado hemos fabricado muchos diseños personalizados para clientes. Al observar cómo son nuestros números de parte para nuestras sondas, como se ve en la sección de Productos, notará que tienen un número de parte como WE30031.0A5. La parte 00 del número de parte especifica la configuración de la microsonda. Electrodos monopolares - 00 implica que no hay montaje especial, con la sonda afilada aislada con Parylene-C, teniendo la longitud, ancho, perfil de punta e impedancia según lo especificado en las tablas para ordenar sus electrodos. Electrodos con Tubo de Poliamida - PT que han sido montados en tubo de poliamida para aumentar la rigidez y proporcionar un grosor adicional de aislamiento. Este montaje se recomienda típicamente cuando electrodos de impedancia bastante alta deben penetrar capas más profundas del cerebro o médula espinal. ST especifica nuestros electrodos bipolares o estereotrodes. Estos electrodos, cuando se ordenan con impedancias menores a 0.5 megaohmios, son excelentes para localizar campos de corriente de estimulación. Estereotrodes de impedancia más alta son excelentes para mejorar el aislamiento de elementos neuronales individuales mediante la grabación simultánea de múltiples unidades en dos microelectrodos muy cercanos. La separación de las puntas es típicamente igual al diámetro del eje de uno de los electrodos usados para fabricar el estereotrodo. Se dispone de diferentes separaciones de punta bajo pedido.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Qué tipo de conectores se usan con nuestros electrodos?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eLos conectores de pines 5482, 5483 están unidos al extremo distal de nuestros electrodos. Puede comprar estos conectores así como el conector hembra, M202, haciendo clic aquí y yendo a nuestra página de accesorios. Muchos usuarios prefieren usar nuestros electrodos sin ningún conector, lo cual está bien. Simplemente retiraremos los conectores por usted si lo solicita. No hay descuento por esto ya que los conectores se colocan al inicio de nuestro proceso de fabricación.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Cuáles son las exposiciones de punta para diferentes valores de impedancia del electrodo?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eLas exposiciones de punta para perfiles de punta \"H\" con afilado por calor tienen aproximadamente entre un 15 y 20 por ciento MÁS exposición. Las exposiciones de punta para perfiles de punta \"B\" romos tienen aproximadamente entre un 15 y 20 por ciento MENOS exposición. Las exposiciones de punta para perfiles de punta \"F\" extra finos tienen aproximadamente entre un 10 y 15 por ciento MÁS exposición.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Problemas para leer la impedancia de sus microelectrodos metálicos?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003col\u003e\r\n\u003cli\u003eRevise su medidor de impedancia, tal vez esté midiendo los valores de impedancia a una frecuencia diferente a 1 kilohertz.\u003c\/li\u003e\r\n\u003cli\u003eVerifique si su medidor de impedancia no tiene un circuito de muestra y retención, en cuyo caso la impedancia se mide inmediatamente al presionar el botón de prueba y la impedancia no tiene oportunidad de estabilizarse.\u003c\/li\u003e\r\n\u003cli\u003eNormalmente la impedancia disminuirá después de unos minutos de que el electrodo esté en la solución salina.\u003c\/li\u003e\r\n\u003cli\u003eA veces los electrodos pueden oxidarse aumentando la impedancia, en cuyo caso recomendamos aplicar aproximadamente entre -3 y -4.5 voltios a través del electrodo en solución salina para limpiar y desoxidar el electrodo.\u003c\/li\u003e\r\n\u003c\/ol\u003e\r\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"0,5 Mohm","offer_id":42265959071834,"sku":"SSM123B05KT","price":375.0,"currency_code":"USD","in_stock":true},{"title":"1,0 MΩ","offer_id":42265959104602,"sku":"SSM123B10KT","price":245.0,"currency_code":"USD","in_stock":true},{"title":"2.0 MΩ","offer_id":42265959137370,"sku":"SSM123B20KT","price":275.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/monopolar-wpolyimide-tubing_1_1ad76a43-a534-428a-832c-c5033fa976e1.png?v=1766395195"},{"product_id":"504123-extension-for-microscope-stands-502004-502005-502006","title":"Extensión para bases pesadas de microscopio (502004, 502005, 502006)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eExtensión para la parte superior de los postes verticales del soporte del microscopio\u003c\/li\u003e\r\n\u003cli\u003eApto para usar con el \u003ca href=\"\/es\/502004-boom-stand\"\u003e502004\u003c\/a\u003e, \u003ca href=\"\/es\/502005-ball-bearing-boom-stand\"\u003e502005 \u003c\/a\u003eo \u003ca href=\"\/es\/502006-boom-clamp-stand\"\u003e502006 \u003c\/a\u003esoportes para microscopios\u003c\/li\u003e\r\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eLongitud de la barra de extensión\u003c\/td\u003e\r\n\u003ctd\u003e280 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDiámetro de la barra de extensión\u003c\/td\u003e\r\n\u003ctd\u003e37.2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003ePoste con rosca en uno o ambos extremos\u003c\/td\u003e\r\n\u003ctd\u003eRosca en un extremo\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTratamiento de superficie\u003c\/td\u003e\r\n\u003ctd\u003eCromo pulido\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eMaterial\u003c\/td\u003e\r\n\u003ctd\u003eMetal\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eColor\u003c\/td\u003e\r\n\u003ctd\u003ePlata\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003ePeso neto\u003c\/td\u003e\r\n\u003ctd\u003e2.31 kg (5.09 lbs.)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42265959923802,"sku":"504123","price":110.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/extension_for_he_4e9c769f64e5d_988037d4-d5d1-4974-b138-2434cc813be6.jpg?v=1766395225"},{"product_id":"504128-reticle-in-10x-eyepiece","title":"Retícula en ocular 10x","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRetícula para ocular de microscopio 10x\u003c\/li\u003e\n\u003cli\u003eDiseñado para usarse con microscopios de la serie PZMIII\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42265960120410,"sku":"504128","price":144.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/reticle_in_10x_e_4e9c75a484a1f_86d79001-89c9-423d-873b-7bcbd3a6e77e.jpg?v=1766395232"},{"product_id":"504129-reticle-in-20x-eyepiece","title":"Retícula de microscopio en ocular 20x","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEsta ocular está diseñada para el microscopio PZMIII\u003c\/li\u003e\n\u003cli\u003eOcular 20x con retículo (compatible con ocular 20x 501371)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42265960775770,"sku":"504129","price":118.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/reticle_in_20x_e_4e9c7609a6ceb_8a0e9d10-d3b3-4dcf-a6f9-f8ff812c459d.jpg?v=1766395238"},{"product_id":"504134-led-ring-light","title":"Luz anular LED para microscopio","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003ePara microscopios estéreo PZMIII y PZMIV\u003c\/li\u003e\r\n\u003cli\u003eIluminación con luz “blanca” — 72 bombillas LED\u003c\/li\u003e\r\n\u003cli\u003eApertura máxima 61 mm\u003c\/li\u003e\r\n\u003cli\u003eLa luz anular está dividida en cuatro áreas y cada área se enciende y apaga por separado\u003c\/li\u003e\r\n\u003cli\u003eBrillo ajustable\u003c\/li\u003e\r\n\u003cli\u003eSeguro contra ESD\u003c\/li\u003e\r\n\u003cli\u003eFuente de alimentación AC 90-264V, 50\/60 Hz, solo con enchufe US\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg style=\"float: right; margin: 5px;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ringlight-1_e2cb55de-51d0-4998-943e-aeb9985b7cd6.jpg?v=1765944635\" alt=\"ringlight-1.jpg\" width=\"337\" height=\"257\" align=\"right\"\u003e\u003c\/p\u003e\r\n\u003ch2\u003eBeneficios\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eIluminación directa superior más cuatro zonas para sombras\u003c\/li\u003e\r\n\u003cli\u003eBajo costo\u003c\/li\u003e\r\n\u003cli\u003eMenos voluminoso que el halógeno\u003c\/li\u003e\r\n\u003cli\u003eLuz fría sin calor\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eUso con microscopio estéreo\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003eEl gráfico a continuación muestra la intensidad de luz medida en todo el espectro utilizando un espectrómetro de matriz de fotodiodos de alto rendimiento.\u003c\/p\u003e\r\n\u003cp\u003e\u003cimg style=\"margin: 5px; float: left;\" title=\"image004.png\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/image004_33cfd64f-e038-4036-a4bc-42378bef5500.jpg?v=1765944641\" alt=\"image004.png\" width=\"455\" height=\"247\"\u003e\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42265961431130,"sku":"504134","price":277.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/led_ring_light_4ee913356b8f8_c3a112c6-cdbf-47c8-bed8-a03e57499bd6.jpg?v=1766395248"},{"product_id":"var-8270-concentric-bipolar-electrodes-with-extension-rhodes-style-tip","title":"Electrodos Bipolares Concéntricos con Extensión, Punta Estilo Rhodes","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eElectrodos concéntricos bipolares con extensión\u003c\/li\u003e\n\u003cli\u003eElija acero inoxidable o platino iridio\u003c\/li\u003e\n\u003cli\u003e625 x 305 x 500 µm, vástago de 10 mm, extensión de 50 mm\u003c\/li\u003e\n\u003cli\u003ePaquete de 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eLos electrodos bipolares concéntricos, diseñados para grabación y estimulación neurológica, son ideales para aplicaciones agudas. El tubo externo de acero inoxidable (E) proporciona soporte para una colocación y manipulación precisas durante la investigación aguda.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCantidad\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePaquete de 3\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/SSM041RC225-tip_med_c32882a8-51fd-4c67-b8a2-c094a00bb7ad.jpg?v=1765944687\" alt=\"punta rhodes\" width=\"500\" height=\"220\"\u003e\u003c\/p\u003e\n\u003ch2\u003eOpciones \u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #0081c2;\" bgcolor=\"#e4e4e4\"\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eCódigo de pedido\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eTipo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eNúcleo metálico  \u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eLongitud (s) \u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eDiámetro exterior total\u003cbr\u003ede la sonda (z)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eDiámetro exterior  \u003cbr\u003emanga interior (x)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"vertical-align: top;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eExtensión (E)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e4e4e4\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSSM041RC225\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBipolar concéntrico con extensión\u003c\/td\u003e\n\u003ctd\u003eAcero inoxidable \u003c\/td\u003e\n\u003ctd\u003e0.4” (10 mm) \u003c\/td\u003e\n\u003ctd\u003eaislado (625 µm)\u003c\/td\u003e\n\u003ctd\u003e305 µm \u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePTM041RC225\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBipolar concéntrico con extensión \u003c\/td\u003e\n\u003ctd\u003ePlatino iridio\u003c\/td\u003e\n\u003ctd\u003e0.4” (10 mm) \u003c\/td\u003e\n\u003ctd\u003eaislado (625 µm)\u003c\/td\u003e\n\u003ctd\u003e305 µm\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e *Todos tienen un eje exterior de acero inoxidable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/MetalMicroelectrodes_IS.pdf\" target=\"_self\"\u003eUso de microelectrodos metálicos recubiertos con Parylene\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003ePreguntas frecuentes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Qué longitud necesito?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLa longitud total de cualquier sistema de electrodos se determina principalmente por la profundidad del tejido que se desea registrar o estimular y el sistema de microavance que se emplea. Las microsondas de tungsteno vienen en longitudes de 76 mm o 125 mm (no se ve 125 µm en el sitio web de WPI) o pueden pedirse a medida en cualquier longitud menor a 5 pulgadas. El platino\/iridio suele venir en longitudes de dos pulgadas y el acero inoxidable en longitudes de 51 mm, pero cualquiera de ellos también puede especificarse en longitudes más cortas o más largas usando tubos de acero inoxidable y poliamida. Debido al alto costo del iridio puro, siempre se monta en tubos de acero inoxidable y poliamida y típicamente mide 50 mm de largo.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Cuál es el grosor del aislamiento?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTodos los electrodos, excepto la microsonda de tungsteno Extra Fina de 3 pulgadas con perfil F, que tiene un recubrimiento de Parylene-C de 1 micrón, tienen 3 micrones de Parylene-C. Se ha demostrado que este grosor funciona mejor para casi todos los perfiles de punta de electrodos que ofrecemos. Seleccionamos 3 micrones para proporcionar un perfil de punta suficientemente pequeño para acercarse a los elementos neuronales, facilitar la inserción del electrodo y minimizar la atenuación en electrodos de mayor impedancia. La atenuación de la señal puede ocurrir debido a un cortocircuito capacitivo al grabar con microsondas de alta impedancia en estructuras profundas, por lo que puede ser necesario un aislamiento adicional en forma de las microsondas KT de WPI, de poliamida. El perfil Extra Fino (ej. TM31C10) para los electrodos de tungsteno de 3 pulgadas ofrece una punta de microsonda extremadamente fina, excelente para grabar en estructuras celulares pequeñas y densamente agrupadas.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Qué impedancia o exposición de punta necesito?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eGracias a nuestro proceso de fabricación único y las propiedades especiales del Parylene-C, podemos exponer cualquier microsonda con precisión y reproducibilidad microscópicas. Cada microsonda se expone individualmente bajo un microscopio de alta potencia, se inspecciona y se caracteriza eléctricamente. Nuestras microsondas tienen un valor de impedancia más bajo para la misma exposición de punta que otros electrodos disponibles comercialmente. Por lo tanto, se recomienda que quienes no hayan usado nuestros electrodos antes especifiquen un rango de impedancia para seleccionar el mejor valor para su aplicación. Además, dado que hemos suministrado microsondas a investigadores durante más de 30 años, podemos ofrecer asesoría experta para seleccionar el mejor diseño de electrodo para su paradigma experimental. Por favor contáctenos y proporcione información sobre los requisitos de su investigación. No hay cargo adicional por especificar un rango de valores de impedancia para cualquier caja de microsondas.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Qué perfil de punta es mejor para mi aplicación?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOfrecemos una variedad de alternativas de punta para quienes prefieren un perfil especializado para su investigación. La selección de la punta puede proporcionar cambios sutiles pero importantes en el rendimiento del electrodo, como se describe a continuación. Se recomienda que los usuarios primerizos experimenten con diferentes perfiles de punta para determinar cuál funciona mejor para sus protocolos de grabación o estimulación. A-Estándar Nuestro perfil de punta estándar presenta un punto afilado pero robusto que ofrece un rendimiento versátil y un equilibrio efectivo entre penetración y durabilidad. Es el perfil de punta más utilizado; recomendamos nuestra punta estándar para la mayoría de las aplicaciones de grabación neural, aunque también es eficaz para la mayoría de los protocolos de estimulación. Empleamos un método de exposición por arco que proporciona un rendimiento preciso y consistente, así como una amplia gama de impedancias disponibles. Aunque este método resulta en una pequeña variabilidad de impedancia entre electrodos, la mayoría de los investigadores lo encuentran muy aceptable para su aplicación. Para quienes necesitan una exposición de punta más exacta, ofrecemos un servicio de exposición láser por un pequeño costo adicional. Por favor contáctenos si cree que este servicio es adecuado para usted. B-Despuntado Nuestros electrodos despuntados están diseñados para tener una punta más redondeada, en forma de bala. Para muchas aplicaciones, la punta despuntada puede ofrecer un mejor rendimiento en estimulación, ya que su perfil más corto puede hacer que el electrodo actúe más como una fuente puntual y proporcione mejor aislamiento. Muchos investigadores consideran que este perfil ofrece mayor selectividad que los perfiles de punta más afilados convencionales y es más apropiado para protocolos de estimulación de mayor intensidad. Algunos investigadores también han observado que el uso de puntas despuntadas reduce la ocurrencia de células perforadas. F-Extra fino Nuestro perfil de punta extra fino presenta un afilado significativamente mayor y una capa de aislamiento más delgada. Este tipo de electrodo se usa comúnmente en preparaciones superficiales donde es necesario grabar en poblaciones celulares pequeñas y densamente agrupadas, como las capas estriadas de las cortezas visual y auditiva. Debido a la naturaleza muy delicada de estas puntas, solo están disponibles en electrodos de tungsteno, en longitud de 3 pulgadas (76 mm) y diámetros de vástago de 0.003\" y 0.005\" (75 y 125 micrones). Para penetraciones mayores a 4 mm en las que la impedancia de la punta es mayor a 1.5 MΩ, recomendamos especificar una capa adicional de tubo de poliamida para reducir el cortocircuito capacitivo y aumentar la rigidez del electrodo. H-Tratado con calor Nuestros electrodos tratados con calor están destinados a investigadores que deben penetrar sus sondas a través de membranas resistentes, como la duramadre de mamíferos grandes. Aplicando una fuente de calor cerca de la punta del electrodo bajo un microscopio, podemos proporcionar un electrodo con una punta de conicidad más gradual que nuestro perfil estándar, además de endurecer el aislamiento de polímero cerca de la punta. Estas modificaciones permiten que el electrodo se inserte más fácilmente a través de membranas resistentes y con menor riesgo de daño en la punta y el aislamiento.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Problemas para leer la impedancia de sus microelectrodos metálicos?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003col\u003e\n\u003cli\u003eRevise su medidor de impedancia, tal vez esté midiendo a una frecuencia diferente a 1 kilohertz.\u003c\/li\u003e\n\u003cli\u003eVerifique si su medidor de impedancia no tiene un circuito de muestreo y retención, en cuyo caso la impedancia se mide inmediatamente al presionar el botón de prueba y no tiene tiempo para estabilizarse.\u003c\/li\u003e\n\u003cli\u003eGeneralmente la impedancia disminuye después de unos minutos de que el electrodo está en solución salina.\u003c\/li\u003e\n\u003cli\u003eA veces los electrodos pueden oxidarse aumentando la impedancia; en ese caso recomendamos aplicar entre -3 y -4.5 voltios a través del electrodo en solución salina para limpiarlo y desoxidar el electrodo.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Qué configuración de electrodo necesito?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eActualmente ofrecemos tres configuraciones diferentes de electrodos, aunque en el pasado hemos fabricado muchos diseños personalizados para clientes. Al observar nuestros números de parte para las sondas, como se ve en la sección de Productos, notará que tienen un número como WE30031.0A5. La parte 00 del número especifica la configuración de la microsonda. Electrodos monopolares - 00 Indica que no tienen montaje especial, con la sonda afilada aislada con Parylene-C, con la longitud, ancho, perfil de punta e impedancia especificados en las tablas para ordenar sus electrodos. Tubo de poliamida - PT Electrodos montados en tubo de poliamida para aumentar la rigidez y proporcionar mayor grosor de aislamiento. Este montaje se recomienda típicamente cuando electrodos de impedancia bastante alta deben penetrar capas profundas del cerebro o médula espinal. ST Especifica nuestros electrodos bipolares o estereotrodes. Estos electrodos, cuando se piden con impedancias menores a 0.5 megaohmios, son excelentes para localizar campos de corriente de estimulación. Los estereotrodes de mayor impedancia son excelentes para mejorar el aislamiento de elementos neuronales individuales mediante la grabación simultánea de múltiples unidades en dos microelectrodos muy cercanos. La separación de las puntas suele ser igual al diámetro del vástago de uno de los electrodos usados para fabricar el estereotrodo. Se dispone de diferentes separaciones de punta bajo pedido.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Qué tipo de conectores se usan con nuestros electrodos?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLos conectores de pines 5482, 5483 se fijan al extremo distal de nuestros electrodos. Puede comprar estos conectores así como el conector hembra, M202, haciendo clic aquí y yendo a nuestra página de accesorios. Muchos usuarios prefieren usar nuestros electrodos sin ningún conector, lo cual está bien. Simplemente retiraremos los conectores si lo solicita. No hay descuento por esto ya que los conectores se fijan al inicio de nuestro proceso de fabricación.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Cuáles son las exposiciones de punta para diferentes valores de impedancia de electrodos?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLas exposiciones de punta para perfiles de punta con conicidad tratada con calor \"H\" tienen aproximadamente un 15 a 20 por ciento MÁS exposición. Las exposiciones de punta para perfiles de punta despuntados \"B\" tienen aproximadamente un 15 a 20 por ciento MENOS exposición. Las exposiciones de punta para perfiles de punta extra fina \"F\" tienen aproximadamente un 10 a 15 por ciento MÁS exposición.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Problemas para leer la impedancia de sus microelectrodos metálicos?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003col\u003e\n\u003cli\u003eRevise su medidor de impedancia, tal vez esté midiendo a una frecuencia diferente a 1 kilohertz.\u003c\/li\u003e\n\u003cli\u003eVerifique si su medidor de impedancia no tiene un circuito de muestreo y retención, en cuyo caso la impedancia se mide inmediatamente al presionar el botón de prueba y no tiene tiempo para estabilizarse.\u003c\/li\u003e\n\u003cli\u003eGeneralmente la impedancia disminuye después de unos minutos de que el electrodo está en solución salina.\u003c\/li\u003e\n\u003cli\u003eA veces los electrodos pueden oxidarse aumentando la impedancia; en ese caso recomendamos aplicar entre -3 y -4.5 voltios a través del electrodo en solución salina para limpiarlo y desoxidar el electrodo.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"Acero inoxidable","offer_id":42265967067226,"sku":"SSM041RC225","price":788.0,"currency_code":"USD","in_stock":true},{"title":"Platino iridio","offer_id":42265967099994,"sku":"PTM041RC225","price":998.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ssm04rc100_2_bb687b59-ba07-4011-8373-1e0c07bb7a0e.png?v=1766395322"},{"product_id":"504328-mini-centrifuge-purple-lid-2-rotors-240v","title":"Mini Centrífuga, tapa morada, 2 rotores, 240V","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eRotor para microtubos de 8 posiciones\u003c\/li\u003e\r\n\u003cli\u003eCompartimento de almacenamiento para rotor de PCR\u003c\/li\u003e\r\n\u003cli\u003eFuncionamiento silencioso\u003c\/li\u003e\r\n\u003cli\u003eArranca y se detiene en segundos\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003e\u003cimg style=\"float: left; margin: 5px;\" title=\"c1008_myfuge_bottom_hr_emsm.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/c1008_myfuge_bottom_hr_emsm_aa7b6116-4a77-4119-abc6-d24d0eff75af.jpg?v=1765944905\" alt=\"c1008_myfuge_bottom_hr_emsm.jpg\" width=\"267\" height=\"239\"\u003e\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:details --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42265980665946,"sku":"504328","price":430.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/mini_centrifuge__4ff6f1cfa995e_d4efaea3-4189-4737-a179-d8ee11ac1302.jpg?v=1766395544"},{"product_id":"var-2273-constant-current-stimulus-isolator","title":"Aislador de Estímulo de Corriente Constante","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003ePulsos bipolares automatizados para carga neta cero en preparaciones biológicas\u003c\/h2\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCorriente constante\u003c\/li\u003e\n\u003cli\u003eModos de estimulación unipolar y bipolar\u003c\/li\u003e\n\u003cli\u003eAlarma incorporada de no cumplimiento\u003c\/li\u003e\n\u003cli\u003eLa entrada está ópticamente aislada\u003c\/li\u003e\n\u003cli\u003eDisparo TTL estándar\u003c\/li\u003e\n\u003cli\u003eModo de prueba CC\u003c\/li\u003e\n\u003cli\u003eAlimentado por baterías alcalinas o recargables de 9 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOpciones\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #0081c2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eNúmero de parte\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eDescripción\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eTipo de batería\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eIncluye cargador\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eA365RC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA365R con un cargador de baterías A362\u003c\/td\u003e\n\u003ctd\u003eBatería recargable\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eSí\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSYS-A365R\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAislador de alto voltaje, bipolar\u003c\/td\u003e\n\u003ctd\u003eBatería recargable\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSYS-A365D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAislador de alto voltaje, bipolar\u003c\/td\u003e\n\u003ctd\u003eBaterías alcalinas\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e_\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eBeneficios\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEl voltaje de cumplimiento es de 100V o más\u003c\/li\u003e\n\u003cli\u003eEl modo bipolar genera automáticamente pulsos alternos positivos y negativos desde entrada TTL\u003c\/li\u003e\n\u003cli\u003eEl modo de prueba simplifica la verificación del rendimiento\u003c\/li\u003e\n\u003cli\u003eEl aislamiento óptico mejora la seguridad de la preparación y reduce la susceptibilidad al ruido\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrofisiología\u003c\/li\u003e\n\u003cli\u003eEstimulación de cortes cerebrales\u003c\/li\u003e\n\u003cli\u003e\nEstimulación cerebral y del SNC \u003cem\u003ein vivo\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eActivado por comandos lógicos convencionales, Modelo \u003cstrong\u003eA365\u003c\/strong\u003e puede ser activado por cualquier generador de pulsos, estimulador o salida de computadora con pulsos bipolares automatizados para carga neta cero en preparaciones biológicas.\u003c\/p\u003e\n\u003ch2\u003eAlarmas audibles de tono dual\u003c\/h2\u003e\n\u003cp\u003eUn tono suena cuando se detecta un circuito de electrodo abierto o cuando se alcanza el cumplimiento del sistema. Un segundo tono opcional suena cuando se aplica una señal a la entrada. También se proporciona un interruptor de prueba para verificar la carga de la batería.\u003c\/p\u003e\n\u003ch2\u003eEntrega de corriente hasta 10 mA a más de 100V\u003c\/h2\u003e\n\u003cp\u003eLas corrientes de estímulo se ajustan usando una perilla de control de tres dígitos y un interruptor de rango de tres posiciones. La corriente de salida sigue los ajustes de control con una precisión mejor al 1%. La corriente de salida es independiente de la carga, y se desarrolla automáticamente un voltaje suficiente para impulsar la corriente deseada a través de la carga, sujeto solo a los límites de cumplimiento. Modelo \u003cstrong\u003eA360LA\u003c\/strong\u003e produce hasta 10 mA de corriente, en tres rangos, con más de 100 V de cumplimiento.\u003c\/p\u003e\n\u003ch2\u003ePolaridad de Salida Bipolar\u003c\/h2\u003e\n\u003cp\u003eLa polaridad de salida se determina mediante un interruptor pulsador en el panel frontal. La corriente bipolar se alterna mediante la forma de onda de comando, configurando pulsos alternos como positivos o negativos.\u003c\/p\u003e\n\u003ch2\u003eAlimentación\u003c\/h2\u003e\n\u003cp\u003eEste\u003cstrong\u003e\u003ca href=\"\/es\/index.php?src=directory\u0026amp;view=products\u0026amp;srctype=detail\u0026amp;refno=2273\u0026amp;category=Physiology\"\u003e \u003c\/a\u003eA365RC\u003c\/strong\u003e Aislador de Estímulos incluye tanto el \u003cstrong\u003eA365R\u003c\/strong\u003e Aislador de Estímulos como el \u003cstrong\u003eA362\u003c\/strong\u003e cargador de baterías. El recargable \u003cstrong\u003eA365R\u003c\/strong\u003e se suministra con un paquete de baterías de hidruro metálico de níquel. El \u003ca href=\"\/es\/sys-a362-a362-battery-charger\"\u003e\u003cstrong\u003eA362\u003c\/strong\u003e Cargador de Baterías\u003c\/a\u003e es necesario con el \u003cstrong\u003eA365R\u003c\/strong\u003e. \u003c\/p\u003e\n\u003cp\u003e NOTA: No destinado para uso humano.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/A365_IMs.pdf\" target=\"_self\"\u003eManual de instrucciones A365\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:specifications --\u003e\n\u003ctable cellpadding=\"2\" cellspacing=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFORMA DE ONDA DE SALIDA\u003c\/td\u003e\n\u003ctd\u003eCC o pulso de corriente\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eRANGOS DE CORRIENTE DE SALIDA\u003c\/td\u003e\n\u003ctd\u003e0.1, 1.0 y 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eERROR DE AMPLITUD DE CORRIENTE\u003c\/td\u003e\n\u003ctd\u003e0.5% de la escala completa, máx.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eRESOLUCIÓN ACTUAL\u003c\/td\u003e\n\u003ctd\u003e0.1% de la escala completa, típico\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEXCURSIÓN DE VOLTAJE DE CARGA DE SALIDA (CUMPLIMIENTO)\u003c\/td\u003e\n\u003ctd\u003e100 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eUMBRAL DE COMANDO EXTERNO\u003c\/td\u003e\n\u003ctd\u003e5 V a 3 mA, mínimo 10 V, máximo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUMBRAL DE DISPARO\u003c\/td\u003e\n\u003ctd\u003e2.0 V a 0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOLARIDAD DE SALIDA\u003c\/td\u003e\n\u003ctd\u003eReversible, interruptor manual o automático\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eTIEMPO DE SUBIDA Y RETARDO DE CORRIENTE\u003c\/td\u003e\n\u003ctd\u003e6 μs, típico (carga de 1 KΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTIEMPO DE CAÍDA Y RETARDO DE CORRIENTE\u003c\/td\u003e\n\u003ctd\u003e10 μs, típico (carga de 1 KΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eRESISTENCIA DE SALIDA A TIERRA\u003c\/td\u003e\n\u003ctd\u003e10\u003csup\u003e12 \u003c\/sup\u003eΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOPTOACOPLADOR\u003c\/td\u003e\n\u003ctd\u003e2500 V, voltaje mínimo de ruptura nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eALIMENTACIÓN: Modelo A365D (pila seca)\u003c\/td\u003e\n\u003ctd\u003e16 baterías alcalinas de 9 V incluidas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eALIMENTACIÓN: Modelo A365R (recargable)\u003c\/td\u003e\n\u003ctd\u003e16 baterías recargables NiMH de 9 V incluidas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eDIMENSIONES\u003c\/td\u003e\n\u003ctd\u003e8.5 x 3.5 x 5 in. (22 x 9 x 12 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePESO DE ENVÍO\u003c\/td\u003e\n\u003ctd\u003e4 lb. (1.8 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cb\u003eYavich, L., Tanila, H., Vepsäläinen, S., \u0026amp; Jäkälä, P. (s.f.).\u003c\/b\u003e Neurobiología de la enfermedad Papel de la ␣-sinucleína en el reclutamiento presináptico de dopamina. \u003ca href=\"https:\/\/doi.org\/10.1523\/JNEUROSCI.2559-04.2004\"\u003ehttps:\/\/doi.org\/10.1523\/JNEUROSCI.2559-04.2004\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIremonger, K. J., Anderson, T. R., Hu, B., \u0026amp; Kiss, Z. H. T. (s.f.).\u003c\/b\u003e Mecanismos celulares que previenen la activación sostenida de la corteza durante la estimulación subcortical de alta frecuencia. \u003ca href=\"https:\/\/doi.org\/10.1152\/jn.00105.2006\"\u003ehttps:\/\/doi.org\/10.1152\/jn.00105.2006\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eRowland, N. C., \u0026amp; Jaeger, D. (s.f.).\u003c\/b\u003e Las respuestas a la estimulación táctil en las neuronas del núcleo cerebeloso profundo resultan de la activación recurrente en múltiples vías. \u003ca href=\"https:\/\/doi.org\/10.1152\/jn.01100.2007\"\u003ehttps:\/\/doi.org\/10.1152\/jn.01100.2007\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eD ’ambrosio, R., Gordon, D. S., Winn, H. R., ’ambrosio, D., Raimondo, D. S., Gordon, H., \u0026amp; Richard, W. (s.f.).\u003c\/b\u003e Papel diferencial del canal KIR y la bomba Na ϩ \/K ϩ en la regulación del K ϩ extracelular en el hipocampo de rata. \u003ca href=\"https:\/\/doi.org\/10.1152\/jn.00240.2001\"\u003ehttps:\/\/doi.org\/10.1152\/jn.00240.2001\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHuda, R., Mccrimmon, D. R., \u0026amp; Martina, M. (s.f.).\u003c\/b\u003e La modulación del pH de los transportadores gliales de glutamato regula la transmisión sináptica en el núcleo del tracto solitario.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eChen, Y., Beffert, U., Ertunc, M., Tang, T.-S., Kavalali, E. T., Bezprozvanny, I., \u0026amp; Herz, J. (s.f.).\u003c\/b\u003e Desarrollo\/Plasticidad\/Reparación Reelin modula la actividad del receptor NMDA en neuronas corticales. \u003ca href=\"https:\/\/doi.org\/10.1523\/JNEUROSCI.1951-05.2005\"\u003ehttps:\/\/doi.org\/10.1523\/JNEUROSCI.1951-05.2005\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eD ’ambrosio, R., Wenzel, J., Schwartzkroin, P. A., Mckhann Ii, G. M., \u0026amp; Janigro, D. (s.f.).\u003c\/b\u003e Especialización funcional y segregación topográfica de los astrocitos hipocampales.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eD ’ambrosio, R., Maris, D. O., Grady, M. S., Winn, H. R., \u0026amp; Janigro, D. (s.f.).\u003c\/b\u003e Homeostasis de K ؉ alterada y propiedades electrofisiológicas modificadas de la glía hipocampal postraumática.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eJi, H., \u0026amp; Shepard, P. D. (n.d.).\u003c\/b\u003e Behavioral\/Systems\/Cognitive La estimulación de la habenula lateral inhibe las neuronas dopaminérgicas del mesencéfalo en ratas mediante un mecanismo mediado por receptores GABA A. \u003ca href=\"https:\/\/doi.org\/10.1523\/JNEUROSCI.0958-07.2007\"\u003ehttps:\/\/doi.org\/10.1523\/JNEUROSCI.0958-07.2007\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eLee, E., Hong, J., Park, Y.-G., Chae, S., Kim, Y., \u0026amp; Kim, D. (2015).\u003c\/b\u003e La actividad cortical del hemisferio izquierdo modula los efectos del estrés en el comportamiento social. \u003ci\u003eScientific Reports\u003c\/i\u003e, \u003ci\u003e5\u003c\/i\u003e, 13342. \u003ca href=\"https:\/\/doi.org\/10.1038\/srep13342\"\u003ehttps:\/\/doi.org\/10.1038\/srep13342\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eGindrat, A.-D., Quairiaux, C., Britz, J., Brunet, D., Lanz, F., Michel, C. M., \u0026amp; Rouiller, E. M. (2015).\u003c\/b\u003e Mapeo EEG de todo el cuero cabelludo de potenciales evocados somatosensoriales en monos macacos. \u003ci\u003eBrain Structure \u0026amp; Function\u003c\/i\u003e, \u003ci\u003e220\u003c\/i\u003e(4), 2121–2142. \u003ca href=\"https:\/\/doi.org\/10.1007\/s00429-014-0776-y\"\u003ehttps:\/\/doi.org\/10.1007\/s00429-014-0776-y\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAvila, I., \u0026amp; Lin, S.-C. (2014).\u003c\/b\u003e Señal de saliencia motivacional en el prosencéfalo basal está acoplada con una velocidad de decisión más rápida y precisa. \u003ci\u003ePLoS Biology\u003c\/i\u003e, \u003ci\u003e12\u003c\/i\u003e(3), e1001811. \u003ca href=\"https:\/\/doi.org\/10.1371\/journal.pbio.1001811\"\u003ehttps:\/\/doi.org\/10.1371\/journal.pbio.1001811\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNguyen, D. P., \u0026amp; Lin, S.-C. (2014).\u003c\/b\u003e Un potencial relacionado con eventos en la corteza frontal impulsado por el prosencéfalo basal. \u003ci\u003eELife\u003c\/i\u003e, \u003ci\u003e3\u003c\/i\u003e, e02148. Recuperado de \u003ca rel=\"noopener\" href=\"https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC3974155\/\" target=\"_blank\"\u003ehttps:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC3974155\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHerrera, C., Directores, R., Panetsos, F., Carlos, P., \u0026amp; Trueba, A. (2014).\u003c\/b\u003e TESIS DOCTORAL Efectos de la estimulación artificial de un nervio periférico seccionado sobre la vía somatosensorial desaferentizada de la rata.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eYounce, J. R., Albaugh, D. L., \u0026amp; Shih, Y.-Y. I. (2014).\u003c\/b\u003e Estimulación cerebral profunda con fMRI simultáneo en roedores. \u003ci\u003eJournal of Visualized Experiments\u003c\/i\u003e, (84), e51271–e51271. \u003ca href=\"https:\/\/doi.org\/10.3791\/51271\"\u003ehttps:\/\/doi.org\/10.3791\/51271\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOulad Ben Taib, N., \u0026amp; Manto, M. (2013).\u003c\/b\u003e Series de estimulación DC epidural del cerebelo ajustan la excitabilidad corticomotora. \u003ci\u003eNeural Plasticity\u003c\/i\u003e, \u003ci\u003e2013\u003c\/i\u003e(10), 1–12. \u003ca href=\"https:\/\/doi.org\/10.1155\/2013\/613197\"\u003ehttps:\/\/doi.org\/10.1155\/2013\/613197\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSyvänen, S., Russmann, V., Verbeek, J., Eriksson, J., Labots, M., Zellinger, C., … Potschka, H. (2013).\u003c\/b\u003e Imagen PET con [11C]quinidina y [11C]laniquidar en un modelo crónico de epilepsia en roedores: Impacto de la epilepsia y la respuesta al medicamento. \u003ci\u003eNuclear Medicine and Biology\u003c\/i\u003e, \u003ci\u003e40\u003c\/i\u003e(6), 764–775. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.nucmedbio.2013.05.008\"\u003ehttps:\/\/doi.org\/10.1016\/j.nucmedbio.2013.05.008\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSchroder, E. A., Lefta, M., Zhang, X., Bartos, D. C., Feng, H.-Z., Zhao, Y., … Delisle, B. P. (2013).\u003c\/b\u003e El reloj molecular del cardiomiocito, regulación de Scn5a y susceptibilidad a arritmias. \u003ci\u003eAmerican Journal of Physiology. Cell Physiology\u003c\/i\u003e, \u003ci\u003e304\u003c\/i\u003e(10), C954-65. \u003ca href=\"https:\/\/doi.org\/10.1152\/ajpcell.00383.2012\"\u003ehttps:\/\/doi.org\/10.1152\/ajpcell.00383.2012\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSchmuckermair, C., Gaburro, S., Sah, A., Landgraf, R., Sartori, S. B., \u0026amp; Singewald, N. (2013).\u003c\/b\u003e Efectos conductuales y neurobiológicos de la estimulación cerebral profunda en un modelo murino de comportamiento con alta ansiedad y depresión. \u003ci\u003eNeuropsychopharmacology : Official Publication of the American College of Neuropsychopharmacology\u003c\/i\u003e, \u003ci\u003e38\u003c\/i\u003e(7), 1234–1244. \u003ca href=\"https:\/\/doi.org\/10.1038\/npp.2013.21\"\u003ehttps:\/\/doi.org\/10.1038\/npp.2013.21\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDalby-Brown, W., Jessen, C., Hougaard, C., Jensen, M. L., Jacobsen, T. A., Nielsen, K. S., … Jørgensen, S. (2013).\u003c\/b\u003e Caracterización de un nuevo modulador positivo de alta potencia de los canales Kv7. \u003ci\u003eEuropean Journal of Pharmacology\u003c\/i\u003e, \u003ci\u003e709\u003c\/i\u003e(1–3), 52–63. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.ejphar.2013.03.039\"\u003ehttps:\/\/doi.org\/10.1016\/j.ejphar.2013.03.039\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eLicko, T., Seeger, N., Zellinger, C., Russmann, V., Matagne, A., \u0026amp; Potschka, H. (2013). \u003c\/b\u003eEl tratamiento con lacosamida tras un estado epiléptico atenúa la pérdida neuronal y las alteraciones en la neurogénesis hipocampal en un modelo eléctrico de estado epiléptico en ratas. \u003ci\u003eEpilepsia\u003c\/i\u003e, \u003ci\u003e54\u003c\/i\u003e(7), 1176–1185. \u003ca href=\"https:\/\/doi.org\/10.1111\/epi.12196\"\u003ehttps:\/\/doi.org\/10.1111\/epi.12196\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAtherton, J. F., Menard, A., Urbain, N., \u0026amp; Bevan, M. D. (2013).\u003c\/b\u003e Depresión a corto plazo de la transmisión sináptica globo pálido externo-núcleo subtalámico e implicaciones para el patrón de actividad subtalámica. \u003ci\u003eThe Journal of Neuroscience : The Official Journal of the Society for Neuroscience\u003c\/i\u003e, \u003ci\u003e33\u003c\/i\u003e(17), 7130–7144. \u003ca href=\"https:\/\/doi.org\/10.1523\/JNEUROSCI.3576-12.2013\"\u003ehttps:\/\/doi.org\/10.1523\/JNEUROSCI.3576-12.2013\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSaha, D., Leong, K., Katta, N., \u0026amp; Raman, B. (2013).\u003c\/b\u003e Métodos de grabación multiunidad para caracterizar la actividad neuronal en los circuitos olfativos de la langosta (\u0026amp;lt;em\u0026amp;gt;Schistocerca Americana\u0026amp;lt;\/em\u0026amp;gt;). \u003ci\u003eJournal of Visualized Experiments\u003c\/i\u003e, (71), e50139–e50139. \u003ca href=\"https:\/\/doi.org\/10.3791\/50139\"\u003ehttps:\/\/doi.org\/10.3791\/50139\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHuda, R., McCrimmon, D. R., \u0026amp; Martina, M. (2013).\u003c\/b\u003e La modulación del pH de los transportadores gliales de glutamato regula la transmisión sináptica en el núcleo del tracto solitario. \u003ci\u003eJournal of Neurophysiology\u003c\/i\u003e, \u003ci\u003e110\u003c\/i\u003e(2), 368–377. \u003ca href=\"https:\/\/doi.org\/10.1152\/jn.01074.2012\"\u003ehttps:\/\/doi.org\/10.1152\/jn.01074.2012\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSonner, P. M., \u0026amp; Ladle, D. R. (2013).\u003c\/b\u003e Desarrollo postnatal temprano de la inhibición presináptica gabaérgica de las conexiones aferentes proprioceptivas Ia en la médula espinal de ratón. \u003ci\u003eJournal of Neurophysiology\u003c\/i\u003e, \u003ci\u003e109\u003c\/i\u003e(8), 2118–2128. \u003ca href=\"https:\/\/doi.org\/10.1152\/jn.00783.2012\"\u003ehttps:\/\/doi.org\/10.1152\/jn.00783.2012\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eZhu, Z., Sierra, A., Burnett, C. M.-L. L., Chen, B., Subbotina, E., Koganti, S. R. K., … Zingman, L. V. (2013).\u003c\/b\u003e Los canales de potasio sensibles al ATP en la sarcolema modulan la función del músculo esquelético bajo cargas de trabajo de baja intensidad. \u003ci\u003eThe Journal of General Physiology\u003c\/i\u003e, \u003ci\u003e143\u003c\/i\u003e(1), 119–134. \u003ca href=\"https:\/\/doi.org\/10.1085\/jgp.201311063\"\u003ehttps:\/\/doi.org\/10.1085\/jgp.201311063\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eBrenowitz, S. D., \u0026amp; Regehr, W. G. (2012).\u003c\/b\u003e Imagen presináptica de fibras de proyección mediante inyección in vivo de indicadores de calcio conjugados con dextrano. \u003ci\u003eCold Spring Harbor Protocols\u003c\/i\u003e, \u003ci\u003e2012\u003c\/i\u003e(4), 465–471. \u003ca href=\"https:\/\/doi.org\/10.1101\/pdb.prot068551\"\u003ehttps:\/\/doi.org\/10.1101\/pdb.prot068551\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eLi, W., Janardhan, A. H., Fedorov, V. V, Sha, Q., Schuessler, R. B., \u0026amp; Efimov, I. R. (2011).\u003c\/b\u003e La terapia de desfibrilación auricular multietapa de baja energía termina la fibrilación auricular con menos energía que una descarga única. \u003ci\u003eCirculation. Arrhythmia and Electrophysiology\u003c\/i\u003e, \u003ci\u003e4\u003c\/i\u003e(6), 917–925. \u003ca href=\"https:\/\/doi.org\/10.1161\/CIRCEP.111.965830\"\u003ehttps:\/\/doi.org\/10.1161\/CIRCEP.111.965830\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eMathis, D. M., Furman, J. L., \u0026amp; Norris, C. M. (2011).\u003c\/b\u003e Preparación de cortes agudos de hipocampo de ratas y ratones transgénicos para el estudio de alteraciones sinápticas durante el envejecimiento y la patología amiloide. \u003ci\u003eJournal of Visualized Experiments\u003c\/i\u003e, (49), e2330–e2330. \u003ca href=\"https:\/\/doi.org\/10.3791\/2330\"\u003ehttps:\/\/doi.org\/10.3791\/2330\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eManto, M. U., Hampe, C. S., Rogemond, V., \u0026amp; Honnorat, J. (2011).\u003c\/b\u003e Implicaciones respectivas de los anticuerpos contra la descarboxilasa del glutamato en el síndrome de persona rígida y la ataxia cerebelosa. \u003ci\u003eOrphanet Journal of Rare Diseases\u003c\/i\u003e, \u003ci\u003e6\u003c\/i\u003e(1), 3. \u003ca href=\"https:\/\/doi.org\/10.1186\/1750-1172-6-3\"\u003ehttps:\/\/doi.org\/10.1186\/1750-1172-6-3\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eKim, J., Woo, J., Park, Y.-G., Chae, S., Jo, S., Choi, J. W., … Kim, D. (2011).\u003c\/b\u003e Los canales de Ca\u003csup\u003e2\u003c\/sup\u003e+ tipo T talámicos median disfunciones del lóbulo frontal causadas por un daño similar a la hipoxia en la corteza prefrontal. \u003ci\u003eThe Journal of Neuroscience : The Official Journal of the Society for Neuroscience\u003c\/i\u003e, \u003ci\u003e31\u003c\/i\u003e(11), 4063–4073. \u003ca href=\"https:\/\/doi.org\/10.1523\/JNEUROSCI.4493-10.2011\"\u003ehttps:\/\/doi.org\/10.1523\/JNEUROSCI.4493-10.2011\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSeo, J. H., Jang, I. K., Kim, H., Yang, M. S., Lee, J. E., Kim, H. E., … Cho, S.-R. (2011).\u003c\/b\u003e La inmunomodulación temprana por células madre mesenquimales trasplantadas por vía intravenosa promueve la recuperación funcional en ratas con lesión de la médula espinal. \u003ci\u003eCell Medicine\u003c\/i\u003e, \u003ci\u003e2\u003c\/i\u003e(2), 55–67. \u003ca href=\"https:\/\/doi.org\/10.3727\/215517911X582788\"\u003ehttps:\/\/doi.org\/10.3727\/215517911X582788\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePelkonen, A., Hiltunen, M., Kiianmaa, K., \u0026amp; Yavich, L. (2010).\u003c\/b\u003e Desbordamiento estimulado de dopamina y expresión de alfa-sinucleína en el núcleo accumbens core distinguen ratas criadas para preferencia diferencial por etanol. \u003ci\u003eJournal of Neurochemistry\u003c\/i\u003e, \u003ci\u003e114\u003c\/i\u003e(4), 1168–1176. \u003ca href=\"https:\/\/doi.org\/10.1111\/j.1471-4159.2010.06844.x\"\u003ehttps:\/\/doi.org\/10.1111\/j.1471-4159.2010.06844.x\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFoust, A. J., Schei, J. L., Rojas, M. J., \u0026amp; Rector, D. M. (2008).\u003c\/b\u003e Análisis de ruido in vitro e in vivo para el registro neural óptico. \u003ci\u003eJournal of Biomedical Optics\u003c\/i\u003e, \u003ci\u003e13\u003c\/i\u003e(4), 044038. \u003ca href=\"https:\/\/doi.org\/10.1117\/1.2952295\"\u003ehttps:\/\/doi.org\/10.1117\/1.2952295\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSchei, J. L., McCluskey, M. D., Foust, A. J., Yao, X.-C., \u0026amp; Rector, D. M. (2008). \u003c\/b\u003ePropagación del potencial de acción imagenada con alta resolución temporal mediante microscopía de video en infrarrojo cercano y luz polarizada. \u003ci\u003eNeuroImage\u003c\/i\u003e, \u003ci\u003e40\u003c\/i\u003e(3), 1034–1043. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.neuroimage.2007.12.055\"\u003ehttps:\/\/doi.org\/10.1016\/j.neuroimage.2007.12.055\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFoust, A. J., \u0026amp; Rector, D. M. (2007). \u003c\/b\u003eSeparando ópticamente la hinchazón neural y la despolarización. \u003ci\u003eNeuroscience\u003c\/i\u003e, \u003ci\u003e145\u003c\/i\u003e(3), 887–899. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.neuroscience.2006.12.068\"\u003ehttps:\/\/doi.org\/10.1016\/j.neuroscience.2006.12.068\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eJi, H., \u0026amp; Shepard, P. D. (2007).\u003c\/b\u003e La estimulación de la habenula lateral inhibe las neuronas dopaminérgicas del mesencéfalo de rata mediante un mecanismo mediado por receptores GABA(A). \u003ci\u003eThe Journal of Neuroscience : The Official Journal of the Society for Neuroscience\u003c\/i\u003e, \u003ci\u003e27\u003c\/i\u003e(26), 6923–6930. \u003ca href=\"https:\/\/doi.org\/10.1523\/JNEUROSCI.0958-07.2007\"\u003ehttps:\/\/doi.org\/10.1523\/JNEUROSCI.0958-07.2007\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eLee, B. H., Lee, K. H., Yoon, D. H., Kim, U. J., Hwang, Y. S., Park, S. K., … Jahng, T. (2005).\u003c\/b\u003e Efectos de la metilprednisolona en la conducción neural de los potenciales evocados motores en ratas con lesión medular. \u003ci\u003eJournal of Korean Medical Science\u003c\/i\u003e, \u003ci\u003e20\u003c\/i\u003e(1), 132–138. \u003ca href=\"https:\/\/doi.org\/10.3346\/jkms.2005.20.1.132\"\u003ehttps:\/\/doi.org\/10.3346\/jkms.2005.20.1.132\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAnderson, T., Hu, B., Pittman, Q., \u0026amp; Kiss, Z. H. T. (2004).\u003c\/b\u003e Mecanismos de la estimulación cerebral profunda: un estudio intracelular en el tálamo de rata. \u003ci\u003eThe Journal of Physiology\u003c\/i\u003e, \u003ci\u003e559\u003c\/i\u003e(1), 301–313. \u003ca href=\"https:\/\/doi.org\/10.1113\/jphysiol.2004.064998\"\u003ehttps:\/\/doi.org\/10.1113\/jphysiol.2004.064998\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSokolow, S., Manto, M., Gailly, P., Molgó, J., Vandebrouck, C., Vanderwinden, J.-M., … Schurmans, S. (2004).\u003c\/b\u003e Transmisión neuromuscular deteriorada y necrosis de fibras musculares esqueléticas en ratones sin intercambiador Na\/Ca 3. \u003ci\u003eJournal of Clinical Investigation\u003c\/i\u003e, \u003ci\u003e113\u003c\/i\u003e(2), 265–273. \u003ca href=\"https:\/\/doi.org\/10.1172\/JCI18688\"\u003ehttps:\/\/doi.org\/10.1172\/JCI18688\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eD’Ambrosio, R., Fairbanks, J. P., Fender, J. S., Born, D. E., Doyle, D. L., \u0026amp; Miller, J. W. (2004). \u003c\/b\u003eEpilepsia postraumática tras lesión por percusión de fluido en la rata. \u003ci\u003eBrain : A Journal of Neurology\u003c\/i\u003e, \u003ci\u003e127\u003c\/i\u003e(Pt 2), 304–314. \u003ca href=\"https:\/\/doi.org\/10.1093\/brain\/awh038\"\u003ehttps:\/\/doi.org\/10.1093\/brain\/awh038\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eShaw, B. K., \u0026amp; Kennedy, G. G. (2002).\u003c\/b\u003e Evidencia de diferencias entre especies en el patrón de distribución del receptor de andrógenos en relación con diferencias entre especies en un comportamiento dependiente de andrógenos. \u003ci\u003eJournal of Neurobiology\u003c\/i\u003e, \u003ci\u003e52\u003c\/i\u003e(3), 203–220. \u003ca href=\"https:\/\/doi.org\/10.1002\/neu.10079\"\u003ehttps:\/\/doi.org\/10.1002\/neu.10079\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eYavich, L., \u0026amp; Tiihonen, J. (2000).\u003c\/b\u003e El etanol modula la liberación evocado de dopamina en el núcleo accumbens de ratón: dependencia del estrés social y la dosis. \u003ci\u003eEuropean Journal of Pharmacology\u003c\/i\u003e, \u003ci\u003e401\u003c\/i\u003e(3), 365–373. Recuperado de \u003ca href=\"http:\/\/www.safetylit.org\/citations\/index.php?fuseaction=citations.viewdetails\u0026amp;citationIds%5B%5D=citjournalarticle_271069_38\"\u003ehttp:\/\/www.safetylit.org\/citations\/index.php?fuseaction=citations.viewdetails\u0026amp;citationIds%5B%5D=citjournalarticle_271069_38\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eKnisley, S. B., Trayanova, N., \u0026amp; Aguel, F. (1999).\u003c\/b\u003e Roles del campo eléctrico y la estructura de la fibra en la estimulación eléctrica cardíaca. \u003ci\u003eBiophysical Journal\u003c\/i\u003e, \u003ci\u003e77\u003c\/i\u003e(3), 1404–1417. \u003ca href=\"https:\/\/doi.org\/10.1016\/S0006-3495(99)76989-4\"\u003ehttps:\/\/doi.org\/10.1016\/S0006-3495(99)76989-4\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Recargable","offer_id":42266068582490,"sku":"SYS-A365R","price":2300.0,"currency_code":"USD","in_stock":true},{"title":"Alcalino","offer_id":42266068615258,"sku":"SYS-A365D","price":1800.0,"currency_code":"USD","in_stock":true},{"title":"Recargable con cargador","offer_id":42266068648026,"sku":"A365RC","price":2700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/a365_1_fc747f0d-6742-4e53-b046-ddaebb5c1dcc.jpg?v=1766396620"},{"product_id":"var-2274-high-current-stimulus-isolator","title":"Aislador de Estímulo de Alta Corriente","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eAislador de estímulo de corriente constante con rango de corriente de 100 mA\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCorriente constante hasta 100 mA\u003c\/li\u003e\n\u003cli\u003eModos de estimulación unipolar o bipolar\u003c\/li\u003e\n\u003cli\u003eAlarma incorporada de incumplimiento\u003c\/li\u003e\n\u003cli\u003eLa entrada está ópticamente aislada\u003c\/li\u003e\n\u003cli\u003eDisparo TTL estándar\u003c\/li\u003e\n\u003cli\u003eModo de prueba de corriente continua\u003c\/li\u003e\n\u003cli\u003eAlimentado por seis baterías recargables de plomo-ácido\u003c\/li\u003e\n\u003cli\u003eCumplimiento de 36V\u003c\/li\u003e\n\u003cli\u003eInterruptores de polaridad de salida y encendido\/apagado de salida\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOpciones\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #0081c2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eCódigo de pedido\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eDescripción\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eTipo de batería\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eIncluye cargador\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eA385RC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA385R con un cargador de batería A382\u003c\/td\u003e\n\u003ctd\u003eBatería recargable\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eSí\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSYS-A385R\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAislador de alta corriente\u003c\/td\u003e\n\u003ctd\u003eBatería recargable\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eBeneficios \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCapacidad de corriente de 100 mA\u003c\/li\u003e\n\u003cli\u003eEl modo bipolar genera automáticamente pulsos alternos positivos y negativos desde la entrada TTL\u003c\/li\u003e\n\u003cli\u003eEl modo de prueba simplifica la verificación del rendimiento\u003c\/li\u003e\n\u003cli\u003eEl aislamiento óptico mejora la seguridad de la preparación y reduce la susceptibilidad al ruido\u003c\/li\u003e\n\u003cli\u003eLos LED de estado de carga de la batería mantienen informado al experimentador sobre el estado de la batería\u003c\/li\u003e\n\u003cli\u003eCargador incluido a precio descontado cuando el sistema se compra como \u003cstrong\u003eA385RC \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAplicaciones \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrofisiología muscular\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eEstimulación muscular in vivo\/in vitro\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEl \u003cstrong\u003eA385\u003c\/strong\u003e es una fuente de corriente ópticamente aislada, que puede generar hasta 100 mA de pulsos de corriente constante unipolares o bifásicos o corriente continua. La duración del pulso se controla manualmente o mediante un comando externo de 5V. La amplitud de la corriente de salida se determina mediante un potenciómetro de 3 dígitos y 10 vueltas. El voltaje máximo de salida entre los electrodos estimulantes es de +36V.\u003c\/p\u003e\n\u003ch2\u003eEntrega corrientes positivas, negativas o bipolares\u003c\/h2\u003e\n\u003cp\u003ePara la entrega bipolar, la polaridad de la salida puede alternarse al estado de polaridad opuesto con cada pulso sucesivo presentado en la entrada. La duración del pulso se controla mediante un voltaje aplicado externamente. El conector de entrada es un BNC estándar, permitiendo usar señales TTL de un sistema de adquisición de datos.\u003c\/p\u003e\n\u003ch2\u003eExcelente precisión y repetibilidad\u003c\/h2\u003e\n\u003cp\u003eLa amplitud de salida se controla mediante un dial de 3 dígitos y diez vueltas como porcentaje del rango seleccionado: por ejemplo, una configuración de 45.6 en el rango de 0-10 mA se traduce en 4.56 mA en la salida. La precisión y repetibilidad son excelentes. Diseñado para estimulación subcutánea, el voltaje máximo de salida en los electrodos estimulantes es de 36 voltios, reduciendo la posibilidad de descargas transcutáneas accidentales. Suena una alarma de cumplimiento\/salida cuando se alcanza el límite de 36V. El circuito interno asegura que los electrodos estén en cortocircuito durante los períodos inactivos (función \"exhaustor de electrodos\"). El \u003cstrong\u003eA385\u003c\/strong\u003e no es apropiada para estimulación transcutánea.\u003c\/p\u003e\n\u003ch2\u003eBatería recargable\u003c\/h2\u003e\n\u003cp\u003eLa capacidad de 1.2 amperios-hora de las seis baterías recargables de plomo-ácido de alta resistencia garantiza que los experimentos durante todo el día no se interrumpan por baterías descargadas cuando se cargan diariamente. Las luces indicadoras y las alarmas audibles mantienen al usuario constantemente informado sobre el estado de carga de la batería. Las baterías se recargan mediante \u003cstrong\u003eA382\u003c\/strong\u003e Cargador del sistema, que está diseñado especialmente para el \u003cstrong\u003eA385\u003c\/strong\u003e, e incluido con el \u003cstrong\u003eA385RC\u003c\/strong\u003e. \u003c\/p\u003e\n\u003cp\u003eNOTA: No está destinado para uso humano.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/A385-IM.pdf\" target=\"_self\"\u003eManual de instrucciones A385\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:specifications --\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFORMA DE ONDA DE SALIDA\u003c\/td\u003e\n\u003ctd\u003eCC o pulso de corriente\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eRANGOS DE CORRIENTE DE SALIDA\u003c\/td\u003e\n\u003ctd\u003e1, 10 y 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eERROR DE AMPLITUD DE CORRIENTE\u003c\/td\u003e\n\u003ctd\u003e0.5% de la escala completa, máximo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eREPETIBILIDAD DE RESOLUCIÓN DE CORRIENTE\u003c\/td\u003e\n\u003ctd\u003e0.1% de la escala completa, típico\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEXCURSIÓN DE VOLTAJE DE CARGA DE SALIDA (CUMPLIMIENTO)\u003c\/td\u003e\n\u003ctd\u003e36 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eVOLTAJE DE COMANDO EXTERNO\u003cbr\u003e  POLARIDAD DE SALIDA\u003cbr\u003e  TIEMPO DE SUBIDA Y RETARDO DE CORRIENTE\u003cbr\u003e  TIEMPO DE CAÍDA Y RETARDO DE CORRIENTE\u003cbr\u003e  RESISTENCIA DE SALIDA A TIERRA\u003cbr\u003e  OPTOACOPLADOR\u003c\/td\u003e\n\u003ctd\u003e5 V a 3 mA mínimo, 8.5 V máximo\u003cbr\u003eEntrega reversible, interruptor manual o conmutación electrónica bipolar\u003cbr\u003e6 μs, típico (carga de 1 KΩ)\u003cbr\u003e10 μs, típico (carga de 1 KΩ)\u003cbr\u003e10\u003csup\u003e12 \u003c\/sup\u003eΩ\u003cbr\u003e2500 V, voltaje mínimo de ruptura nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\" bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003ePOTENCIA\u003c\/td\u003e\n\u003ctd\u003eSeis baterías recargables de plomo-ácido (requiere cargador complementario A382)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eDIMENSIONES\u003c\/td\u003e\n\u003ctd\u003e8.5 x 3.5 x 5 in. (22 x 9 x 12 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\" bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003ePESO DE ENVÍO\u003c\/td\u003e\n\u003ctd\u003e5 lb. (2.3 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cb\u003eLin, C., Disterhoft, J., \u0026amp; Weiss, C. (2016).\u003c\/b\u003e Condicionamiento clásico del parpadeo ocular señalizado por bigotes en ratones con la cabeza fija. \u003ci\u003eJournal of Visualized Experiments\u003c\/i\u003e, (109), e53310–e53310. \u003ca href=\"https:\/\/doi.org\/10.3791\/53310\"\u003ehttps:\/\/doi.org\/10.3791\/53310\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePathak, D., Shields, L. Y., Mendelsohn, B. A., Haddad, D., Lin, W., Gerencser, A. A., … Nakamura, K. (2015).\u003c\/b\u003e El papel del ATP derivado de las mitocondrias en el reciclaje de vesículas sinápticas. \u003ci\u003eJournal of Biological Chemistry\u003c\/i\u003e, \u003ci\u003e290\u003c\/i\u003e(37), 22325–22336. \u003ca href=\"https:\/\/doi.org\/10.1074\/jbc.M115.656405\"\u003ehttps:\/\/doi.org\/10.1074\/jbc.M115.656405\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePan, P.-Y., Marrs, J., \u0026amp; Ryan, T. A. (2015).\u003c\/b\u003e El transportador vesicular de glutamato 1 orquesta el reclutamiento de otras proteínas de carga de vesículas sinápticas durante el reciclaje de vesículas sinápticas. \u003ci\u003eThe Journal of Biological Chemistry\u003c\/i\u003e, \u003ci\u003e290\u003c\/i\u003e(37), 22593–22601. \u003ca href=\"https:\/\/doi.org\/10.1074\/jbc.M115.651711\"\u003ehttps:\/\/doi.org\/10.1074\/jbc.M115.651711\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eZarzoso, M., Mironov, S., Guerrero-Serna, G., Willis, B. C., \u0026amp; Pandit, S. V. (2014).\u003c\/b\u003e Remodelación ventricular en conejos con dieta alta en grasas sostenida. \u003ci\u003eActa Physiologica\u003c\/i\u003e, \u003ci\u003e211\u003c\/i\u003e(1), 36–47. \u003ca href=\"https:\/\/doi.org\/10.1111\/apha.12185\"\u003ehttps:\/\/doi.org\/10.1111\/apha.12185\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePan, P.-Y., \u0026amp; Ryan, T. A. (2012).\u003c\/b\u003e La calbindina controla la probabilidad de liberación en las neuronas dopaminérgicas del área tegmental ventral. \u003ci\u003eNature Neuroscience\u003c\/i\u003e, \u003ci\u003e15\u003c\/i\u003e(6), 813–815. \u003ca href=\"https:\/\/doi.org\/10.1038\/nn.3099\"\u003ehttps:\/\/doi.org\/10.1038\/nn.3099\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eLi, T., Finch, E. A., Graham, V., Zhang, Z.-S., Ding, J.-D., Burch, J., … Rosenberg, P. (2012).\u003c\/b\u003e La señalización STIM1-Ca(2+) es necesaria para el crecimiento hipertrófico del músculo esquelético en ratones. \u003ci\u003eMolecular and Cellular Biology\u003c\/i\u003e, \u003ci\u003e32\u003c\/i\u003e(15), 3009–3017. \u003ca href=\"https:\/\/doi.org\/10.1128\/MCB.06599-11\"\u003ehttps:\/\/doi.org\/10.1128\/MCB.06599-11\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Aislador de alta corriente","offer_id":42266069303386,"sku":"SYS-A385R","price":2600.0,"currency_code":"USD","in_stock":true},{"title":"A385R con cargador de batería A382","offer_id":42266069336154,"sku":"A385RC","price":2800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/a385_1_21c50241-dbef-4ba6-8e57-5073212a442a.jpg?v=1766396637"},{"product_id":"var-2275-linear-stimulus-isolator","title":"Aislador de Estímulo Lineal","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eReplica una forma de onda programada de cualquier forma o polaridad\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eCrea una réplica de corriente constante de formas de onda analógicas\u003c\/li\u003e\r\n\u003cli\u003eLa amplitud de la corriente de salida está controlada por voltaje\u003c\/li\u003e\r\n\u003cli\u003eVoltaje de entrada de –10V a +10V\u003c\/li\u003e\r\n\u003cli\u003e3 rangos de corriente de 100 μA a 10 mA\u003c\/li\u003e\r\n\u003cli\u003eResistencias de prueba integradas\u003c\/li\u003e\r\n\u003cli\u003ePantalla digital muestra la corriente entregada para corrientes no variables de duración adecuada\u003c\/li\u003e\r\n\u003cli\u003eAjuste de compensación de salida ±70 V rango de cumplimiento\u003c\/li\u003e\r\n\u003cli\u003eElija baterías: NiMH con cargador (A395RC), Alcalinas (SYS-A395D), NiMH (SYS-A395R)\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOpciones\u003c\/h2\u003e\r\n\u003ctable\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eNúmero de pieza\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eDescripción\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eTipo de batería\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eIncluye cargador\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003e\u003cstrong\u003eA395RC\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003eA395R con cargador de baterías A362\u003c\/td\u003e\r\n\u003ctd\u003e17 pilas recargables NiMH de 9V\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\"\u003eSí\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cstrong\u003eSYS-A395R\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003eAislador lineal de estímulo\u003c\/td\u003e\r\n\u003ctd\u003e17 pilas recargables NiMH de 9V\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\"\u003eNo\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003e\u003cstrong\u003eSYS-A395D\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003eAislador lineal de estímulo\u003c\/td\u003e\r\n\u003ctd\u003e17 pilas alcalinas de 9V\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\"\u003e_\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eBeneficios\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eLa amplitud de la corriente está controlada por voltaje\u003c\/li\u003e\r\n\u003cli\u003eResistencias de prueba integradas\u003c\/li\u003e\r\n\u003cli\u003eLos LED de error se iluminan cuando la corriente es menor que la ordenada por el voltaje de control\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eNeurociencia\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eTodos los aisladores de estímulo WPI están diseñados para suministrar corriente constante, porque el umbral de corriente (no el voltaje) es el parámetro más cuantitativamente reproducible para la estimulación de nervios y músculos. Modelo \u003cstrong\u003eA395\u003c\/strong\u003e dispensa corriente de manera reproducible desde sus terminales de salida; la amplitud está determinada por el RANGO de corriente seleccionado y el voltaje de entrada. La amplitud de la corriente es “constante”, es decir, independiente de la resistencia de la carga, siempre que el producto I x R (carga) no exceda el voltaje disponible de la batería. Un indicador visual (los LED de cumplimiento) muestra si I x R alcanza este límite. Cuando la unidad está fuera de cumplimiento, uno de los dos LED (etiquetados - y +) se ilumina, dependiendo de la dirección en que fluye la corriente. Modelo \u003cstrong\u003eA395D\u003c\/strong\u003e puede generar un voltaje de 70V o más a través de sus terminales de SALIDA. Puede estar seguro de que la amplitud de la corriente es la seleccionada siempre que la caída de voltaje a través de la carga (camino del electrodo de estímulo) no alcance la magnitud del voltaje de alimentación. Los LED de cumplimiento serán visibles. Entonces, sabrá que:\u003c\/p\u003e\r\n\u003cp\u003e• Se seleccionó demasiada corriente para una carga dada o\u003c\/p\u003e\r\n\u003cp\u003e• La resistencia entre electrodos era demasiado alta o el circuito del electrodo estaba abierto.\u003c\/p\u003e\r\n\u003ch2\u003eSalida de corriente definida por el usuario en varias formas\u003c\/h2\u003e\r\n\u003cp\u003eModelo \u003cstrong\u003eA395\u003c\/strong\u003e genera una corriente de salida definida por el usuario con forma de onda; CC, CA, pulso y combinaciones. Funciona con batería, está fotoeléctricamente aislado de la tensión de entrada, el instrumento regenera corrientes de salida que son linealmente proporcionales a las formas de onda de tensión analógica proporcionadas por su convertidor D\/A o generador de señales (ver diagrama abajo).\u003c\/p\u003e\r\n\u003cp\u003eEl \u003cstrong\u003eA395\u003c\/strong\u003e es ideal para adquisición de datos y generadores de estimuladores.\u003c\/p\u003e\r\n\u003ch2\u003eEntrega de corriente para rangos seleccionados\u003c\/h2\u003e\r\n\u003cp\u003eUna entrada de 10 V produce la corriente máxima de salida para el rango de corriente seleccionado. (Por ejemplo, 100 µA, 1 mA o 10 mA) Los controles del panel frontal permiten generar corriente continua. Las señales aplicadas externamente pueden superponerse simultáneamente (desplazamiento de CC). Las lámparas de advertencia indican circuito abierto o condiciones de corriente excesiva.\u003c\/p\u003e\r\n\u003ch2\u003eEl medidor digital muestra corriente continua o promedio de salida\u003c\/h2\u003e\r\n\u003cp\u003eEl medidor de pantalla digital muestra la corriente continua medida o la corriente promedio de salida. Las lámparas de sobrecarga indican cuando la tensión de salida ha alcanzado el límite positivo o negativo de tensión de cumplimiento. \u003cbr\u003e\u003cimg style=\"margin: 5px;\" title=\"a395io.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/a395io_d206c5a4-8b4e-4197-9884-761a1c6cb823.jpg?v=1765945527\" alt=\"a395io.jpg\" width=\"392\" height=\"176\"\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eNOTA\u003c\/strong\u003e: No está destinado para uso humano.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/A395-IM.pdf\" target=\"_self\"\u003eManual de instrucciones A395\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCORRIENTE DE SALIDA, Imax\u003c\/td\u003e\r\n\u003ctd\u003e3 rangos: 100 μA, 1 mA y 10 mA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eRANGO DE TENSIÓN DE SALIDA\u003c\/td\u003e\r\n\u003ctd\u003e±70 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eANCHO DE BANDA DE SALIDA\u003c\/td\u003e\r\n\u003ctd\u003e10 kHz (medido a través de carga de 1 KΩ)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eRESISTENCIA DE ENTRADA\u003c\/td\u003e\r\n\u003ctd\u003e\u0026gt;20 MΩ\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTENSIÓN DE ENTRADA @ Imax\u003c\/td\u003e\r\n\u003ctd\u003e±10 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eERROR DE LINEALIDAD DE ENTRADA\/SALIDA\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt;0.5%\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTIEMPO DE SUBIDA Y BAJADA\u003c\/td\u003e\r\n\u003ctd\u003e26 μs @ 10 KΩ\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eALIMENTACIÓN: Modelo A395D\u003c\/td\u003e\r\n\u003ctd\u003e17 baterías alcalinas de 9 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eALIMENTACIÓN: Modelo A395R\u003c\/td\u003e\r\n\u003ctd\u003e17 baterías recargables NiMH de 9 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eDIMENSIONES\u003c\/td\u003e\r\n\u003ctd\u003e6.5 x 4 x 3.5 in. (16 x 10 x 9 cm)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ePESO DE ENVÍO\u003c\/td\u003e\r\n\u003ctd\u003e4 lb. (1.8 kg)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cb\u003eChemla, S., Witharana, W. K. L., \u0026amp; McNaughton, B. L. (2016).\u003c\/b\u003e Efectos espacio-temporales posteriores a la estimulación transcraneal de corriente continua sobre la actividad evocado sensorial en la S 1 de rata: un estudio piloto VSDI. Recuperado de \u003ca href=\"https:\/\/www.semanticscholar.org\/paper\/Spatiotemporal-after-effects-of-transcranial-direct-Chemla-Witharana\/ebfca5444c8b7c0133217e62756e75f4c0c727d5\"\u003ehttps:\/\/www.semanticscholar.org\/paper\/Spatiotemporal-after-effects-of-transcranial-direct-Chemla-Witharana\/ebfca5444c8b7c0133217e62756e75f4c0c727d5\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003eMárquez-Ruiz, J., Ammann, C., Leal-Campanario, R., Ruffini, G., Gruart, A., \u0026amp; Delgado-García, J. M. (2016).\u003c\/b\u003e La percepción táctil sintética inducida por estimulación transcraneal de corriente alterna puede sustituir al estímulo sensorial natural en conejos comportándose. \u003ci\u003eScientific Reports\u003c\/i\u003e, \u003ci\u003e6\u003c\/i\u003e(1), 19753. \u003ca href=\"https:\/\/doi.org\/10.1038\/srep19753\"\u003ehttps:\/\/doi.org\/10.1038\/srep19753\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003eKim, H. N., Jung, W. B., Kang, M. J., Im, G. H., Lee, J. H., \u0026amp; Choe, B.-Y. (2015). \u003c\/b\u003eCambios en el metabolismo cerebral de glucosa en el cerebro de rata tras estimulación eléctrica de la pata delantera a diferentes frecuencias. \u003ci\u003eNeuroReport\u003c\/i\u003e, \u003ci\u003e26\u003c\/i\u003e(4), 197–205. \u003ca href=\"https:\/\/doi.org\/10.1097\/WNR.0000000000000327\"\u003ehttps:\/\/doi.org\/10.1097\/WNR.0000000000000327\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003eMadison, R. D., Robinson, G. A., Krarup, C., Moldovan, M., Li, Q., \u0026amp; Wilson, W. A. (2014).\u003c\/b\u003e Electrofóresis in vitro y electrofisiología in vivo del nervio periférico usando estimulación con campo DC. \u003ci\u003eJournal of Neuroscience Methods\u003c\/i\u003e, \u003ci\u003e225\u003c\/i\u003e, 90–96. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.jneumeth.2014.01.018\"\u003ehttps:\/\/doi.org\/10.1016\/j.jneumeth.2014.01.018\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003eAli, M. M., Sellers, K. K., \u0026amp; Fröhlich, F. (2013).\u003c\/b\u003e La estimulación transcraneal con corriente alterna modula la actividad de redes corticales a gran escala mediante resonancia de red. \u003ci\u003eThe Journal of Neuroscience : The Official Journal of the Society for Neuroscience\u003c\/i\u003e, \u003ci\u003e33\u003c\/i\u003e(27), 11262–11275. \u003ca href=\"https:\/\/doi.org\/10.1523\/JNEUROSCI.5867-12.2013\"\u003ehttps:\/\/doi.org\/10.1523\/JNEUROSCI.5867-12.2013\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003eAyata, C., Shin, H. K., Dileköz, E., Atochin, D. N., Kashiwagi, S., Eikermann-Haerter, K., \u0026amp; Huang, P. L. (2013).\u003c\/b\u003e La hiperlipidemia altera los reflejos cerebrovasculares y empeora el defecto de perfusión isquémica. \u003ci\u003eJournal of Cerebral Blood Flow \u0026amp; Metabolism\u003c\/i\u003e, \u003ci\u003e33\u003c\/i\u003e(6), 954–962. \u003ca href=\"https:\/\/doi.org\/10.1038\/jcbfm.2013.38\"\u003ehttps:\/\/doi.org\/10.1038\/jcbfm.2013.38\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003eVastani, N., Seifert, B., Spahn, D. R., \u0026amp; Maurer, K. (2013).\u003c\/b\u003e Sensibilidades de los nervios aferentes sensoriales primarios de rata al magnesio. \u003ci\u003eEuropean Journal of Anaesthesiology\u003c\/i\u003e, \u003ci\u003e30\u003c\/i\u003e(1), 21–28. \u003ca href=\"https:\/\/doi.org\/10.1097\/EJA.0b013e32835949ab\"\u003ehttps:\/\/doi.org\/10.1097\/EJA.0b013e32835949ab\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003eJacob, S., Johansson, C., \u0026amp; Fridberger, A. (2013).\u003c\/b\u003e Alteraciones inducidas por ruido en la mecánica coclear, electromotilidad y amplificación coclear. \u003ci\u003ePflügers Archiv - Revista Europea de Fisiología\u003c\/i\u003e, \u003ci\u003e465\u003c\/i\u003e(6), 907–917. \u003ca href=\"https:\/\/doi.org\/10.1007\/s00424-012-1198-4\"\u003ehttps:\/\/doi.org\/10.1007\/s00424-012-1198-4\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003ePothmann, L., Wilkens, L. A., \u0026amp; Hofmann, M. H. (2012).\u003c\/b\u003e Dos modos de procesamiento de información en el sistema electrosensorial del pez pala (Polyodon spathula). \u003ci\u003eJournal of Comparative Physiology A\u003c\/i\u003e, \u003ci\u003e198\u003c\/i\u003e(1), 1–10. \u003ca href=\"https:\/\/doi.org\/10.1007\/s00359-011-0681-2\"\u003ehttps:\/\/doi.org\/10.1007\/s00359-011-0681-2\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003eCouchman, K., Grothe, B., \u0026amp; Felmy, F. (2010).\u003c\/b\u003e Las neuronas del Olivar Superior Medial reciben sorprendentemente pocas entradas excitatorias e inhibitorias con fuerza equilibrada y dinámica a corto plazo. \u003ci\u003eJournal of Neuroscience\u003c\/i\u003e, \u003ci\u003e30\u003c\/i\u003e(50), 17111–17121. \u003ca href=\"https:\/\/doi.org\/10.1523\/JNEUROSCI.1760-10.2010\"\u003ehttps:\/\/doi.org\/10.1523\/JNEUROSCI.1760-10.2010\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003eTai, C., Wang, J., Wang, X., Roppolo, J. R., \u0026amp; de Groat, W. C. (2007). \u003c\/b\u003eReflejo de vaciado en gatos con lesión crónica de la médula espinal inducido por la estimulación y bloqueo de los nervios pudendos. \u003ci\u003eNeurourology and Urodynamics\u003c\/i\u003e, \u003ci\u003e26\u003c\/i\u003e(6), 879–886. \u003ca href=\"https:\/\/doi.org\/10.1002\/nau.20430\"\u003ehttps:\/\/doi.org\/10.1002\/nau.20430\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003eLang, P. M., Burgstahler, R., Haberberger, R. V, Sippel, W., \u0026amp; Grafe, P. (2005).\u003c\/b\u003e Un péptido de conus bloquea los receptores nicotínicos de axones no mielinizados en nervios humanos. \u003ci\u003eNeuroreport\u003c\/i\u003e, \u003ci\u003e16\u003c\/i\u003e(5), 479–483. Recuperado de \u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/15770155\"\u003ehttp:\/\/www.ncbi.nlm.nih.gov\/pubmed\/15770155\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003eIrnich, D., Tracey, D. J., Polten, J., Burgstahler, R., \u0026amp; Grafe, P. (2002).\u003c\/b\u003e El ATP estimula axones periféricos en humanos, ratas y ratones--participación diferencial de los receptores adenosínicos A(2B) y purinérgicos P2X. \u003ci\u003eNeuroscience\u003c\/i\u003e, \u003ci\u003e110\u003c\/i\u003e(1), 123–129. Recuperado de \u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/11882377\"\u003ehttp:\/\/www.ncbi.nlm.nih.gov\/pubmed\/11882377\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003eIrnich, D., Burgstahler, R., Bostock, H., \u0026amp; Grafe, P. (2001).\u003c\/b\u003e El ATP afecta tanto a los axones como a las células de Schwann de las fibras C no mielinizadas. \u003ci\u003ePain\u003c\/i\u003e, \u003ci\u003e92\u003c\/i\u003e(3), 343–350. Recuperado de \u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/11376907\"\u003ehttp:\/\/www.ncbi.nlm.nih.gov\/pubmed\/11376907\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"NiMH","offer_id":42266071203930,"sku":"SYS-A395R","price":2700.0,"currency_code":"USD","in_stock":true},{"title":"Alcalino","offer_id":42266071236698,"sku":"SYS-A395D","price":2300.0,"currency_code":"USD","in_stock":true},{"title":"Recargable con cargador","offer_id":42266071269466,"sku":"A395RC","price":2900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/a395_2_0922e145-cec0-44ec-ba40-4656879a8914.jpg?v=1766396656"},{"product_id":"ez-155-stand-alone-vaporizer-unit","title":"Unidad Vaporizadora Independiente con Conectores Macho y Hembra","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePara usar con sistemas de anestesia EZ\u003c\/li\u003e\n\u003cli\u003eGraduaciones finas para un control preciso\u003c\/li\u003e\n\u003cli\u003eDisponible en tres configuraciones\u003c\/li\u003e\n\u003cli\u003eCompatible con el EZ-7000 y el EZ-B800\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266132906074,"sku":"EZ-155","price":1595.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ez-155_c3b1e70e-c8d0-4e39-9db4-84ce56c8fa97.jpg?v=1766397641"},{"product_id":"ez-e27000-mobile-workstation-22-x-21-top","title":"Estación de Trabajo Móvil, superficie 22\" x 21\"","description":"\u003c!-- section:details --\u003e\n\u003cp class=\"body-text\"\u003eDos estaciones de trabajo móviles, construidas con acero inoxidable de alta resistencia y ruedas con bloqueo, integran todos tus componentes EZ-Anesthesia en una unidad portátil. Los estantes laterales abiertos acomodan cilindros de 20 lb, y los prácticos orificios de 2\" permiten una fácil instalación de las líneas de gas y eléctricas. Debajo de la superficie de trabajo de cada estación móvil hay un estante abierto y un gabinete con cerradura. \u003cstrong\u003e E-25000 \u003c\/strong\u003e ofrece una superficie de trabajo de 42\"x24\" y puede contener hasta cuatro cilindros. El E-27000 tiene una superficie de trabajo de 22\"x21\" y puede contener hasta dos cilindros. Estos sistemas son fáciles de montar y proporcionan máxima flexibilidad y movilidad.\u003c\/p\u003e\n\u003cp class=\"body-text\"\u003e\u003cimg style=\"margin: 5px; float: left; width: 264px; height: 480px;\" title=\"27000loaded.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/27000loaded_0d0c6b94-be93-488b-9bdb-347d135a66aa.jpg?v=1765946350\" alt=\"27000loaded.jpg\" width=\"264\" height=\"480\"\u003e\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266140573786,"sku":"EZ-E27000","price":4662.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ez-e27000_8c7c3df5-b839-45db-8241-4f015aec36f2.jpg?v=1766397815"},{"product_id":"flexref-flexible-dri-ref-reference-electrode","title":"Electrodo de referencia flexible Dri-Ref","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDiámetro de 1.5 mm\u003c\/li\u003e\n\u003cli\u003eFuga de electrolito extremadamente baja\u003c\/li\u003e\n\u003cli\u003ePotencial estable y reproducible con baja resistencia\u003c\/li\u003e\n\u003cli\u003eResistente químicamente a ácidos y bases fuertes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBeneficios\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePuede usarse con electrodos selectivos de iones sin contaminación del electrodo de referencia\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMedición de bajo volumen y baja concentración de sal (SDR)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePuede usarse con electrodos selectivos de iones\u003c\/h2\u003e\n\u003cp\u003eAunque la solución interna de relleno contiene KCl, la baja fuga de fluido significa que Dri-Ref puede usarse en combinación con electrodos selectivos de iones, incluidos los de K.\u003csup\u003e+\u003c\/sup\u003e y Cl\u003csup\u003e-\u003c\/sup\u003e, sin contaminación significativa del electrodo de referencia.\u003cbr\u003eLos electrodos Dri-Ref son resistentes químicamente a ácidos y álcalis fuertes. Los electrodos Dri-Ref no son adecuados para su uso en disolventes orgánicos. Además, el FLEXREF largo y delgado puede manipularse fácilmente para adaptarse a configuraciones experimentales difíciles.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSUPER-Dri-Ref\u003c\/strong\u003e – Con un diámetro de 2 mm, SUPER-Dri-Ref no presenta fuga de electrolito. Exhibiendo la estabilidad eléctrica de una celda de referencia clásica de unión fluida, este electrodo muestra baja resistencia y un potencial de media celda estable, esencialmente independiente de la concentración de electrolito de la muestra. SUPER-Dri-Ref es ideal para mediciones de bajo volumen y baja concentración de sal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrodo de referencia micro\u003c\/strong\u003e – Con solo 450 µm de diámetro y una pulgada de largo, el nuevo electrodo de referencia DRIREF-450 puede usarse junto con otros sensores en áreas con espacio limitado y volúmenes de muestra muy pequeños.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReferencia Luer-Tip\u003c\/strong\u003e – La conexión macho luer en la parte frontal del DRIREF-L permite conectarlo fácilmente a un puerto hembra luer.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/DriRef_IM.pdf\"\u003eManual de instrucciones Flex Ref\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:specifications --\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #0081c2;\"\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eDRIREF-450\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eDRIREF-5\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eDRIREF-2\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eFLEXREF\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eSDR\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eDRIREF-L\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eDRIREF-5SH\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eDRIREF-2SH\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eLONGITUD\u003c\/td\u003e\n\u003ctd\u003e2.54 cm\u003c\/td\u003e\n\u003ctd\u003e9 cm\u003c\/td\u003e\n\u003ctd\u003e13 cm\u003c\/td\u003e\n\u003ctd\u003e13 cm\u003c\/td\u003e\n\u003ctd\u003e9 cm\u003c\/td\u003e\n\u003ctd\u003e7.5 cm\u003c\/td\u003e\n\u003ctd\u003e3.5 cm\u003c\/td\u003e\n\u003ctd\u003e2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDIÁMETRO\u003c\/td\u003e\n\u003ctd\u003e450 µm\u003c\/td\u003e\n\u003ctd\u003e4.7 mm\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003ctd\u003e1.5 mm\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003ctd\u003eLuer estándar\u003c\/td\u003e\n\u003ctd\u003e4.7 mm\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eCONSTRUCCIÓN\u003c\/td\u003e\n\u003ctd\u003eVidrio recubierto\u003c\/td\u003e\n\u003ctd\u003eEpoxi\u003c\/td\u003e\n\u003ctd\u003eIsoplast™\u003c\/td\u003e\n\u003ctd\u003eTeflón™\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003ctd\u003ePolipropileno\u003c\/td\u003e\n\u003ctd\u003eEpoxi\u003c\/td\u003e\n\u003ctd\u003eIsoplast™\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRESISTENCIA (TÍPICA)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 K Ω\u003c\/td\u003e\n\u003ctd\u003e~500 Ω\u003c\/td\u003e\n\u003ctd\u003e~2.7 KΩ\u003c\/td\u003e\n\u003ctd\u003e~2.7 KΩ\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 KΩ\u003c\/td\u003e\n\u003ctd\u003e~500 Ω\u003c\/td\u003e\n\u003ctd\u003e~500 Ω\u003c\/td\u003e\n\u003ctd\u003e~2.7 KΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eFUGA DE ELECTROLITO (ML\/HR)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e~7.4×10⁻⁷\u003c\/td\u003e\n\u003ctd\u003e ~5.7×10⁻⁸\u003c\/td\u003e\n\u003ctd\u003e ~5.7×10⁻⁸\u003c\/td\u003e\n\u003ctd\u003e —\u003c\/td\u003e\n\u003ctd\u003e7.4×10⁻⁷\u003c\/td\u003e\n\u003ctd\u003e~7.4×10⁻⁷\u003c\/td\u003e\n\u003ctd\u003e~5.7×10⁻⁸\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLONGITUD DEL CABLE\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"8\"\u003e30 pulg. (76 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eCONECTOR\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"8\"\u003e Punta de 2 mm       \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolución de relleno\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"8\"\u003e KCl       \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266148405338,"sku":"FLEXREF","price":158.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/flexref_6de6300c-fa58-4c47-8fc6-37c2a9b9945c.png?v=1766397950"},{"product_id":"iso-cop-2-iso-cop-2-carbon-monoxide-sensor-2mm","title":"Sensor de monóxido de carbono ISO-COP-2 - 2mm","description":"\u003c!-- section:details --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ISO-COP_DS.pdf\" target=\"_self\"\u003eHaga clic aquí para ver la hoja de datos más reciente.\u003c\/a\u003e\u003c\/p\u003e\r\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003ePara usar con \u003cstrong\u003eApollo1000\u003c\/strong\u003e, \u003cstrong\u003eApollo4000\u003c\/strong\u003e, \u003ca href=\"\/es\/tbr4100-four-channel-free-radical-analyzer\"\u003e\u003cstrong\u003eTBR4100\u003c\/strong\u003e\u003c\/a\u003e y \u003ca href=\"\/es\/tbr1025-one-channel-free-radical-analyzer\"\u003e\u003cstrong\u003eTBR1025\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/li\u003e\r\n\u003cli\u003eTiempo de respuesta: \u0026lt;10 seg\u003c\/li\u003e\r\n\u003cli\u003eLímite mínimo de detección: ~10nM\u003c\/li\u003e\r\n\u003cli\u003eSensibilidad: ~0.5pA\/nM\u003c\/li\u003e\r\n\u003cli\u003eAplicación: Cultivos celulares\u003c\/li\u003e\r\n\u003cli\u003ePaquete de 1\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp class=\"p2\"\u003e \u003c\/p\u003e\r\n\u003cp class=\"p2\"\u003eEste sensor de CO está compuesto por un cuerpo de acero inoxidable de 2.0mm con una funda cubierta por una membrana reemplazable. La funda está llena de electrolito. Es un sensor amperométrico diseñado para usarse en cultivos celulares y aplicaciones similares.\u003c\/p\u003e\r\n\u003cp class=\"p2\"\u003eEn principio, el CO difunde a través de la membrana permeable al gas y luego se oxida a CO\u003csub\u003e2\u003c\/sub\u003e en el electrodo de trabajo del sensor. Esta oxidación\u003cspan class=\"Apple-converted-space\"\u003e  \u003c\/span\u003ecrea una corriente con una magnitud directamente relacionada con la concentración de CO en solución.\u003c\/p\u003e\r\n\u003cp class=\"p2\"\u003eEstá diseñado para usarse con los analizadores de radicales libres \u003cspan class=\"s1\"\u003e\u003cstrong\u003eTRB4100 \u003c\/strong\u003e\u003c\/span\u003e(4 canales) o \u003cspan class=\"s1\"\u003e\u003cstrong\u003eTBR1025 \u003c\/strong\u003e\u003c\/span\u003e(1 canal)\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003ede WPI.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eNOTA\u003c\/strong\u003e: Los biosensores de 2mm vienen con una funda de membrana de repuesto, una jeringa de 1cc, una aguja MicroFil MF28G67 y 10mL de solución de llenado.\u003c\/p\u003e\r\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/2mmkit_32fb4c10-9e4c-4b80-b795-44058e210142.jpg?v=1765946641\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/2mmkit_32fb4c10-9e4c-4b80-b795-44058e210142.jpg?v=1765946641\" alt=\"Los biosensores de 2mm vienen con piezas de repuesto\" width=\"377\" height=\"212\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003ctable\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/Xy_vTV1v-Z0\" width=\"600\" height=\"450\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/DNCFTwzAoo4\" width=\"600\" height=\"450\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/www.fasebj.org\/content\/early\/2005\/01\/27\/fj.04-2169fje.full.pdf\" target=\"_blank\"\u003e\u003cstrong\u003eRoberto Motterlini, Philip Sawle, Sandip Bains, Jehad Hammad, Roger Alberto, Roberta Foresti, Colin J. Green\u003c\/strong\u003e \"CORM-A1: una nueva molécula liberadora de monóxido de carbono con actividad farmacológica\" \u003cem\u003eThe FASEB Journal\u003c\/em\u003e artículo exprés 10.1096\/fj.04-2169fje, 19 de noviembre de 2004.\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266180255834,"sku":"ISO-COP-2","price":1467.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/iso-cop-2_7f05b7f7-13ba-49b4-b067-ea397c6f3e71.jpg?v=1766398235"},{"product_id":"var-2962-hydrogen-peroxide-microsensors","title":"Microsensores de peróxido de hidrógeno","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eMediciones cuantitativas directas de peróxido de hidrógeno en muestras biológicas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrodo de referencia incorporado\u003c\/li\u003e\n\u003cli\u003eSensor de peróxido de hidrógeno integrado irrompible con dimensión de punta de 100 µm\u003c\/li\u003e\n\u003cli\u003ePara uso con Apollo1000, Apollo4000, \u003cstrong\u003e\u003ca href=\"\/es\/tbr4100-four-channel-free-radical-analyzer\"\u003eTBR4100\u003c\/a\u003e\u003c\/strong\u003e y \u003cstrong\u003e\u003ca href=\"\/es\/tbr1025-one-channel-free-radical-analyzer\"\u003eTBR1025\u003c\/a\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eRequiere cable \u003ca href=\"\/es\/91580-microsensor-adapter-cable\"\u003e\u003cstrong\u003e91580\u003c\/strong\u003e\u003c\/a\u003e (se vende por separado)\u003c\/li\u003e\n\u003cli\u003ePaquete de 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOpciones\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #0081c2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eCódigo de pedido\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003e\u003cspan class=\"choice\"\u003eLongitud de la punta\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003e\u003cspan class=\"choice\"\u003eDiámetro de la fibra\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eForma\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eCantidad del paquete\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISO-HPO-100\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-5 mm\u003c\/td\u003e\n\u003ctd\u003e100 µm\u003c\/td\u003e\n\u003ctd\u003eRecto\u003c\/td\u003e\n\u003ctd\u003epaquete de 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eISO-HPO-100-LXX \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-10 mm\u003c\/td\u003e\n\u003ctd\u003e100 µm\u003c\/td\u003e\n\u003ctd\u003eForma en L, longitud personalizada\u003c\/td\u003e\n\u003ctd\u003epaquete de 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e- Sensor disponible en incrementos de longitud de 1 mm (por ejemplo, 1 mm, 2 mm, 3 mm...)\u003cbr\u003e- La sensibilidad del sensor varía con la longitud y el diámetro.\u003c\/p\u003e\n\u003cp\u003eVea la última \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/biosensors_DS.pdf\"\u003eFicha técnica del biosensor\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/6GzNh0XRfq8\" width=\"560\" height=\"315\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2\u003eBeneficios\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTiempo de respuesta: \u0026lt; 5 s (90%)\u003c\/li\u003e\n\u003cli\u003eLímite de detección: 1 nM - 1 mM\u003c\/li\u003e\n\u003cli\u003eDeriva: \u0026lt; 1.0 pA\/min. (\u0026lt; 2 pA\/min. para la forma en L)\u003c\/li\u003e\n\u003cli\u003eSensibilidad: 1 pA\/nM \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDetección de HPO en tejido\/microvasos\u003c\/li\u003e\n\u003cli\u003eForma en L para estudios en baño de tejido\u003c\/li\u003e\n\u003cli\u003eHipodérmico para fácil inserción en tejido\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA pesar de la reconocida importancia de este oxidante en biología, las mediciones en tiempo real a bajas concentraciones han sido difíciles. Los sensores de peróxido de hidrógeno desarrollados por WPI están diseñados para complementar los enfoques fluorescentes de alta sensibilidad existentes con una medición cuantitativa directa en muestras biológicas en el rango bajo de nM.\u003c\/p\u003e\n\u003cp\u003eEl \u003cstrong\u003eISO-HPO-2 \u003c\/strong\u003ees un sensor de acero inoxidable de 2.0 mm, con mangas de membrana reemplazables (600012) y un electrolito interno recargable (100042). Está diseñado para su uso en cultivos celulares y aplicaciones similares.\u003c\/p\u003e\n\u003cp\u003eEl \u003cstrong\u003eISO-HPO-100\u003c\/strong\u003e es un micro sensor de peróxido de hidrógeno con un diámetro de punta de 100 µm diseñado para su uso en tejidos y aplicaciones similares. El diseño se basa en un electrodo sensor de alambre de platino recubierto con una membrana patentada para mejorar la detección de H\u003csub\u003e2\u003c\/sub\u003eO\u003csub\u003e2\u003c\/sub\u003e.\u003c\/p\u003e\n\u003cp\u003eEstos sensores incorporan la tecnología patentada de electrodos combinados de WPI, mediante la cual el elemento sensor de peróxido de hidrógeno y el electrodo de referencia separado están encerrados dentro de un diseño único de sonda con blindaje de Faraday. Se ha demostrado que este diseño mejora el rendimiento durante las mediciones y minimiza el tamaño total del sensor.\u003c\/p\u003e\n\u003cp\u003eNuestros sensores de peróxido de hidrógeno (H\u003csub\u003e2\u003c\/sub\u003eO\u003csub\u003e2\u003c\/sub\u003e) funcionan con los analizadores de radicales libres \u003cstrong\u003eTBR4100\u003c\/strong\u003e y \u003cstrong\u003eTBR1025\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003ePeróxido de hidrógeno en sistemas biológicos\u003c\/h2\u003e\n\u003cp\u003eEl peróxido de hidrógeno se produce en sistemas biológicos por vías controladas a bajas concentraciones que afectan la señalización celular. A concentraciones más altas, las células inflamatorias producen cantidades locales intensas de este oxidante para eliminar patógenos. En el progreso de enfermedades humanas, puede ocurrir la formación descontrolada de peróxido de hidrógeno a partir de la cadena respiratoria mitocondrial y enzimas como la xantina oxidasa (Prof. Victor Darley-Usmar, Univ. de Alabama, comunicación personal). \u003c\/p\u003e\n\u003ch2\u003eSensor de peróxido de hidrógeno en una vaina hipodérmica\u003c\/h2\u003e\n\u003cp\u003eEl \u003cstrong\u003eISO-HPO-100H\u003c\/strong\u003e está encerrado en una aguja hipodérmica. La imagen a continuación muestra la punta de la aguja y el sensor encerrado visto a través de un microscopio.\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/tip002sm_a5a3ce79-2125-4e09-a276-f6da4716f7f2.jpg?v=1765946650\" alt=\"Punta de aguja\" width=\"395\" height=\"327\"\u003e \u003c\/p\u003e\n\u003ch2\u003eSensor de peróxido de hidrógeno en forma de L\u003c\/h2\u003e\n\u003cp\u003eEl \u003cstrong\u003eISO-HPO-100-L\u003c\/strong\u003e es un sensor único de óxido nítrico en forma de L diseñado específicamente para su uso en estudios de baño de tejido y aplicaciones similares (por ejemplo, ver el \u003cstrong\u003eMYOBATH\u003c\/strong\u003e de WPI). La forma del sensor ha sido diseñada para facilitar la colocación del electrodo dentro del lumen del vaso tisular bajo estudio.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ISO_HPO_100_L_Hy_4edd30744b4b0_1bab3427-4e88-405a-bbfd-163bef7411a2.jpg?v=1765946656\" alt=\"ISO-HPO-100L en forma de L\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ISO-HPO-100_IM.pdf\" target=\"_self\"\u003eManual de instrucciones ISO-HPO-100\u003cbr\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd valign=\"middle\"\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"middle\"\u003e\r\n\u003cp\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eISO-HPO-100\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"middle\"\u003e\r\n\u003cp\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eISO-HPO-100 H\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd valign=\"middle\"\u003eAPLICACIÓN\u003c\/td\u003e\r\n\u003ctd valign=\"middle\"\u003eTejido\/Microvasos\u003c\/td\u003e\r\n\u003ctd valign=\"middle\"\u003eVaina hipodérmica\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"middle\"\u003eDIÁMETRO DEL SENSOR\u003c\/td\u003e\r\n\u003ctd valign=\"middle\"\u003e100 µm\u003c\/td\u003e\r\n\u003ctd valign=\"middle\"\u003e100 µm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd valign=\"middle\"\u003eTIEMPO DE RESPUESTA\u003c\/td\u003e\r\n\u003ctd valign=\"middle\"\u003e\u0026lt; 5 SEG (90%)\u003c\/td\u003e\r\n\u003ctd valign=\"middle\"\u003e\u0026lt; 5 SEG (90%)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"middle\"\u003eLÍMITE DE DETECCIÓN\u003c\/td\u003e\r\n\u003ctd valign=\"middle\"\u003e1 nM a 1 mM\u003c\/td\u003e\r\n\u003ctd valign=\"middle\"\u003e\u0026lt; 10 nM a 1 mM\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd valign=\"middle\"\u003eDERIVA\u003c\/td\u003e\r\n\u003ctd valign=\"middle\"\u003e\u0026lt; 2.0 pA\/min\u003c\/td\u003e\r\n\u003ctd valign=\"middle\"\u003e\u0026lt; 2.0 pA\/min\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"middle\"\u003eSENSIBILIDAD\u003c\/td\u003e\r\n\u003ctd valign=\"middle\"\u003e1 pA\/nM\u003c\/td\u003e\r\n\u003ctd valign=\"middle\"\u003e1 pA\/nM\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd class=\"td7\" valign=\"middle\"\u003eINTERFERENCIA FISIOLÓGICA\u003c\/td\u003e\r\n\u003ctd valign=\"middle\"\u003eContactar a WPI\u003c\/td\u003e\r\n\u003ctd valign=\"middle\"\u003eContactar a WPI\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eXie, L., Feng, H., Li, S., Meng, G., Liu, S., Tang, X., … Ji, Y. (2016). SIRT3 media el efecto antioxidante del sulfuro de hidrógeno en células endoteliales. \u003ci\u003eAntioxidants \u0026amp; Redox Signaling\u003c\/i\u003e, \u003ci\u003e24\u003c\/i\u003e(6), 329–343. \u003ca href=\"http:\/\/doi.org\/10.1089\/ars.2015.6331\"\u003ehttp:\/\/doi.org\/10.1089\/ars.2015.6331\u003c\/a\u003e \u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Recto, Personalizar longitud de punta 1-5 mm","offer_id":42266181927002,"sku":"ISO-HPO-100","price":1750.0,"currency_code":"USD","in_stock":true},{"title":"Forma L, Personalizar longitud de punta 1-10 mm","offer_id":42266181992538,"sku":"ISO-HPO-100-LXX","price":1525.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/iso-hpo-100_4d9d964f-5e77-4639-a487-e1b351bb0428.jpg?v=1766398243"},{"product_id":"iso-hpo-2-hydrogen-peroxide-macro-sensor","title":"Macrosensor de peróxido de hidrógeno","description":"\u003c!-- section:details --\u003e\n\u003cp\u003eConsulte la última \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/biosensors_DS.pdf\"\u003eFicha Técnica del Biosensor\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eManga de membrana de polímero permeable al gas que bloquea líquidos, iones y partículas\u003c\/li\u003e\n\u003cli\u003eElectrodo de referencia incorporado\u003c\/li\u003e\n\u003cli\u003ePara uso con \u003cstrong\u003eApollo1000\u003c\/strong\u003e, \u003cstrong\u003eApollo4000\u003c\/strong\u003e, \u003ca href=\"\/es\/tbr4100-four-channel-free-radical-analyzer\"\u003e\u003cstrong\u003eTBR4100\u003c\/strong\u003e\u003c\/a\u003e y \u003cstrong\u003e\u003ca href=\"\/es\/tbr1025-one-channel-free-radical-analyzer\"\u003eTBR1025\u003c\/a\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePaquete de 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBeneficios\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTiempo de respuesta: \u0026lt; 5 s (90%)\u003c\/li\u003e\n\u003cli\u003eLímite de detección: \u0026lt; 100 nM a 100 μM (100 mM personalizado)\u003c\/li\u003e\n\u003cli\u003eDeriva: \u0026lt; 0.2 pA\/min\u003c\/li\u003e\n\u003cli\u003eSensibilidad: 8 pA\/μM\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCultivos celulares\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eEl \u003cstrong\u003eISO-HPO-2 \u003c\/strong\u003ees un sensor de acero inoxidable de 2.0 mm, con mangas de membrana reemplazables (600012) y un electrolito interno recargable (100042). Está diseñado para su uso en cultivos celulares y aplicaciones similares.\u003c\/p\u003e\n\u003cp\u003eEl \u003cstrong\u003eISO-HPO-100\u003c\/strong\u003e es un microsensor de peróxido de hidrógeno con punta de 100 µm de diámetro diseñado para su uso en tejidos y aplicaciones similares. El diseño se basa en un electrodo sensor de alambre de platino recubierto con una membrana patentada para mejorar la detección de H\u003csub\u003e2\u003c\/sub\u003eO\u003csub\u003e2 \u003c\/sub\u003e.\u003c\/p\u003e\n\u003cp\u003eEstos sensores incorporan la tecnología de electrodos combinados patentada por WPI, mediante la cual el elemento sensor de peróxido de hidrógeno y el electrodo de referencia separado están encerrados dentro de un diseño de sonda con blindaje de Faraday. Se ha demostrado que este diseño mejora el rendimiento durante las mediciones y minimiza el tamaño total del sensor.\u003c\/p\u003e\n\u003cp\u003eNuestros sensores de peróxido de hidrógeno (H\u003csub\u003e2\u003c\/sub\u003eO\u003csub\u003e2\u003c\/sub\u003e) funcionan con los analizadores de radicales libres \u003cstrong\u003eTBR4100\u003c\/strong\u003e y \u003cstrong\u003eTBR1025\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNOTA\u003c\/strong\u003e: Los biosensores de 2 mm vienen con una manga de membrana de repuesto, jeringa de 1 cc, una aguja MicroFil \u003cstrong\u003eMF28G67\u003c\/strong\u003e y 10 mL de solución de llenado.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/2mmkit_93e7fd8b-0317-4f27-ab94-04b5f5fbb1f9.jpg?v=1765946668\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/2mmkit_93e7fd8b-0317-4f27-ab94-04b5f5fbb1f9.jpg?v=1765946668\" alt=\"Los biosensores de 2mm vienen con piezas de repuesto\" width=\"377\" height=\"212\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003ePeróxido de hidrógeno en sistemas biológicos\u003c\/h2\u003e\n\u003cp\u003eEl peróxido de hidrógeno se produce en sistemas biológicos por vías controladas a bajas concentraciones que afectan la señalización celular. A concentraciones más altas, las células inflamatorias producen cantidades locales intensas de este oxidante para eliminar patógenos. En el progreso de enfermedades humanas, puede ocurrir la formación descontrolada de peróxido de hidrógeno a partir de la cadena respiratoria mitocondrial y enzimas como la xantina oxidasa (Prof. Victor Darley-Usmar, Univ. de Alabama, comunicación personal). \u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ISO-HPO-2_IMs.pdf\" target=\"_self\"\u003eManual de instrucciones ISO-HPO-2\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/Xy_vTV1v-Z0\" width=\"600\" height=\"450\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/DNCFTwzAoo4\" width=\"600\" height=\"450\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cb\u003eOlson, K. R., Gao, Y., DeLeon, E. R., Arif, M., Arif, F., Arora, N., \u0026amp; Straub, K. D. (2017).\u003c\/b\u003e Catalasa como oxido-reductasa sulfuro-sulfuro: un regulador antiguo (¿y moderno?) de especies reactivas de azufre (RSS). \u003ci\u003eRedox Biology\u003c\/i\u003e, \u003ci\u003e12\u003c\/i\u003e, 325–339. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.redox.2017.02.021\"\u003ehttps:\/\/doi.org\/10.1016\/j.redox.2017.02.021\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDeLeon, E. R., Gao, Y., Huang, E., Arif, M., Arora, N., Divietro, A., … Olson, K. R. (2016). \u003c\/b\u003eUn caso de identidad equivocada: ¿son las especies reactivas de oxígeno en realidad especies reactivas de sulfuro? \u003ci\u003eAmerican Journal of Physiology-Regulatory, Integrative and Comparative Physiology\u003c\/i\u003e, \u003ci\u003e310\u003c\/i\u003e(7), R549–R560. \u003ca href=\"https:\/\/doi.org\/10.1152\/ajpregu.00455.2015\"\u003ehttps:\/\/doi.org\/10.1152\/ajpregu.00455.2015\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOrellano, L. A. A., Almeida, S. A., Campos, P. P., \u0026amp; Andrade, S. P. (2015).\u003c\/b\u003e Efectos angiopreventivos versus angiopromotores del alopurinol en el modelo de esponja murina. \u003ci\u003eMicrovascular Research\u003c\/i\u003e, \u003ci\u003e101\u003c\/i\u003e, 118–126. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.mvr.2015.07.003\"\u003ehttps:\/\/doi.org\/10.1016\/j.mvr.2015.07.003\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePandolfi, C., Pottosin, I., Cuin, T., Mancuso, S., \u0026amp; Shabala, S. (2010). \u003c\/b\u003eEspecificidad de los efectos de las poliaminas en la cinética del flujo iónico inducido por NaCl y la mejora del estrés salino en plantas. \u003ci\u003ePlant and Cell Physiology\u003c\/i\u003e, \u003ci\u003e51\u003c\/i\u003e(3), 422–434. \u003ca href=\"https:\/\/doi.org\/10.1093\/pcp\/pcq007\"\u003ehttps:\/\/doi.org\/10.1093\/pcp\/pcq007\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266182025306,"sku":"ISO-HPO-2","price":1550.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/iso-hpo-2_6c772d74-c587-4420-a12b-3d8335e88b1e.jpg?v=1766398265"},{"product_id":"iso-nop-nitric-oxide-sensor-2mm","title":"Sensor de óxido nítrico - 2mm","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\u003cul\u003e\r\n\u003cli\u003eExcelente sensibilidad al NO: 2 pA\/nM\u003c\/li\u003e\r\n\u003cli\u003eTiempo de respuesta rápido: \u0026lt; 5 s\u003c\/li\u003e\r\n\u003cli\u003eAltamente sensible\u003c\/li\u003e\r\n\u003cli\u003ePara uso con \u003cstrong\u003eApollo1000\u003c\/strong\u003e, \u003cstrong\u003eApollo4000\u003c\/strong\u003e, \u003ca href=\"\/es\/tbr4100-four-channel-free-radical-analyzer\"\u003e\u003cstrong\u003eTBR4100\u003c\/strong\u003e\u003c\/a\u003e y \u003ca href=\"\/es\/tbr1025-one-channel-free-radical-analyzer\"\u003e\u003cstrong\u003eTBR1025\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/li\u003e\r\n\u003cli\u003eLímite inferior de detección: 1 nM\u003c\/li\u003e\r\n\u003cli\u003ePaquete de 1\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eBeneficios\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eSensores de NO de 2 mm para detección de NO en cultivos celulares\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eCultivo celular, suspensión celular\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eNOTA\u003c\/strong\u003e: Los biosensores de 2 mm vienen con una funda de membrana de repuesto, jeringa de 1 cc, una aguja MicroFil MF28G67 y 10 mL de solución de llenado.\u003c\/p\u003e\r\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/2mmkit_4b5419ee-2154-4580-923a-98d55a408454.jpg?v=1765946678\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/2mmkit_4b5419ee-2154-4580-923a-98d55a408454.jpg?v=1765946678\" alt=\"Los biosensores de 2 mm vienen con piezas de repuesto\" width=\"377\" height=\"212\"\u003e\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cem\u003e\u003cimg style=\"float: right; margin: 5px;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/nopx-ray_0d88dc0c-bbb8-4fa9-b917-17c565023a14.jpg?v=1765946684\" alt=\" una radiografía abdominal\" width=\"219\" height=\"298\" align=\"right\"\u003eLa imagen (a la derecha) muestra una radiografía abdominal de un aparato que consiste en dos sondas personalizadas ISO-NOP de óxido nítrico, un catéter de pH de 4 canales y un tubo nasogástrico de teflón. (Cortesía del Prof. K.E.L. McColl, Departamento Universitario de Medicina y Terapéutica, Western Infirmary, Glasgow, Escocia., lijima, K., et al. Gastroenterology 2003:\u003cstrong\u003e122\u003c\/strong\u003e:1248-1257)\u003c\/em\u003e\u003c\/p\u003e\r\n\u003ch2\u003eSelectividad de los sensores de NO de WPI\u003c\/h2\u003e\r\n\u003cp\u003eEl sensor ideal de NO debe ser insensible a otras especies reactivas que probablemente estén presentes en el entorno de medición. El sensor convencional de NO de fibra de carbono recubierto con Nafion exhibe una gran respuesta a dichas especies. La tecnología única del sensor de NO de WPI utiliza una membrana superficial novedosa que amplifica la respuesta al NO mientras elimina las respuestas a una amplia gama de especies reactivas, incluyendo nitrito, ácido ascórbico, peróxido de hidrógeno, catecolaminas y mucho más.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ISONOP_IMs.pdf\" target=\"_self\"\u003eManual de instrucciones ISO-NOP con procedimiento de calibración\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ctable\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/Xy_vTV1v-Z0\" width=\"600\" height=\"450\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/DgP0Riv9eS8\" width=\"600\" height=\"450\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eDiámetro exterior\u003c\/td\u003e\r\n\u003ctd\u003e2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTiempo de respuesta\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 5 s\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eLímite\/rango inferior de detección\u003c\/td\u003e\r\n\u003ctd\u003e1 nM\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eLímite\/rango superior de detección\u003c\/td\u003e\r\n\u003ctd\u003e80 µM (más allá de 80 µM, no se garantiza la precisión del sensor)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eSensibilidad nominal (sensor nuevo)\u003c\/td\u003e\r\n\u003ctd\u003e≤2 pA\/nM\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eInterferente (Coeficiente de selectividad)\u003c\/td\u003e\r\n\u003ctd\u003eNaNO\u003csub\u003e2\u003c\/sub\u003e (10\u003csup\u003e-6\u003c\/sup\u003e o mejor)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eDeriva\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt;1 pA\/min.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eVoltaje de Poise\u003c\/td\u003e\r\n\u003ctd\u003e865 mV\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eCorriente típica de línea base en reposo, 25°C\u003c\/td\u003e\r\n\u003ctd\u003e3,000 pA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRango aceptable de línea base\u003c\/td\u003e\r\n\u003ctd\u003e1,000-8,000 pA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eTiempo de polarización\u003c\/td\u003e\r\n\u003ctd\u003eMás de 12 horas\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSolución de polarización recomendada\u003c\/td\u003e\r\n\u003ctd\u003e0.1 M KI\/H\u003csub\u003e\u003csub\u003e2\u003c\/sub\u003e\u003c\/sub\u003eSO\u003csub\u003e4\u003c\/sub\u003e\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eInterferencia fisiológica\u003c\/td\u003e\r\n\u003ctd\u003eNinguno\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cobject id=\"wobj-841-iso-nop-q\" style=\"width: 100%; height: 193px;\" data=\"https:\/\/www.bioz.com\/v_widget_6_0\/841\/iso-nop\/\" type=\"text\/html\" width=\"300\" height=\"150\"\u003e\u003c\/object\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cdiv id=\"bioz-w-pb-841-iso-nop-q-div\" style=\"width: 100%;\"\u003e\n\u003ca id=\"bioz-w-pb-841-iso-nop-q\" style=\"font-size: 12px; text-decoration: none; color: #00afe9;\" href=\"https:\/\/www.bioz.com\/\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg style=\"width: 11px; height: 11px; vertical-align: baseline; padding-bottom: 0px; margin-left: 0px; margin-bottom: 0px; float: none;\" src=\"https:\/\/cdn.bioz.com\/assets\/favicon.png\" alt=\"impulsado por bioz\"\u003e Impulsado por Bioz\u003c\/a\u003e \u003ca style=\"font-size: 12px; text-decoration: none; float: right; color: transparent;\" href=\"https:\/\/www.bioz.com\/result\/iso-nop\/product\/World%20Precision%20Instruments\/?cn=iso-nop\" target=\"_blank\" rel=\"noopener\"\u003e Ver más detalles en Bioz\u003c\/a\u003e\n\u003c\/div\u003e\r\n\u003c!------------------------------ end embed code ---------------------------------------\u003e\r\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266182123610,"sku":"ISO-NOP","price":1150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/iso-nop_dbb257ea-1d20-4c8d-8d94-00d8fd1b99a5.jpg?v=1766398271"},{"product_id":"var-2968-micro-nitric-oxide-sensors","title":"Microsensores de óxido nítrico","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eSensores de 7 y 30 µm con rendimiento excepcional – ideales para tejidos y microvasos\u003c\/h2\u003e\n\u003ctable style=\"height: 17px;\" align=\"right\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 251px; text-align: center;\" bgcolor=\"#fe8800\"\u003e\u003cspan style=\"color: #ffffff; font-size: 14pt;\"\u003e\u003cstrong\u003e \u003cspan style=\"color: #ffffff;\"\u003e\u003ca href=\"\/es\/var-3422-snap-s-nitroso-n-acetyl-d-penicillamine\"\u003e¡No olvides el SNAP!\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003eExcelente selectividad para NO\u003c\/li\u003e\n\u003cli\u003eTiempo de respuesta rápido\u003c\/li\u003e\n\u003cli\u003eAltamente sensible\u003c\/li\u003e\n\u003cli\u003ePara uso con \u003cstrong\u003eApollo1000\u003c\/strong\u003e, \u003cstrong\u003eApollo4000\u003c\/strong\u003e, \u003ca href=\"\/es\/tbr4100-four-channel-free-radical-analyzer\"\u003e\u003cstrong\u003eTBR4100\u003c\/strong\u003e\u003c\/a\u003e y \u003ca href=\"\/es\/tbr1025-one-channel-free-radical-analyzer\"\u003e\u003cstrong\u003eTBR1025\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eRequiere cable \u003ca href=\"\/es\/91580-microsensor-adapter-cable\"\u003e\u003cstrong\u003e91580\u003c\/strong\u003e\u003c\/a\u003e (se venden por separado)\u003c\/li\u003e\n\u003cli\u003ePaquete de 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOpciones\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #0081c2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eCódigo de pedido\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003e\u003cspan class=\"choice\"\u003eLongitud\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003e\u003cspan class=\"choice\"\u003eDiámetro de punta\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003e\u003cspan class=\"choice\"\u003eForma\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISO-NOP007\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2 mm\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e7 µm\u003c\/td\u003e\n\u003ctd\u003eRecto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISO-NOPF3005\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.5 mm\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e30 µm \u003c\/td\u003e\n\u003ctd\u003eRecto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISO-NOPF3020\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2 mm\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e30 µm \u003c\/td\u003e\n\u003ctd\u003eRecto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/DgP0Riv9eS8\" width=\"560\" height=\"315\"\u003e\u003c\/iframe\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e Beneficios\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRespuesta lineal en un amplio rango dinámico de concentración de NO\u003c\/li\u003e\n\u003cli\u003eLos electrodos secos no requieren fundas ni solución de llenado\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMedición de NO en microvasos\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEl \u003cstrong\u003eISO-NOP007\u003c\/strong\u003e tiene un diámetro de punta de solo 7 micrones y una longitud de 2 mm. La respuesta es lineal en un amplio rango dinámico de concentración de NO. El diseño se basa en una sola fibra de carbono recubierta con la membrana selectiva de NO de WPI. Un límite de detección de aproximadamente 1 nM de NO hace que este electrodo sea ideal para su uso en tejidos y microvasos.\u003c\/p\u003e\n\u003cp\u003eEl \u003cstrong\u003eISO-NOP30\u003c\/strong\u003e tiene un diámetro de punta de 30 micrones y está disponible en dos longitudes de punta diferentes: \u003cstrong\u003eISO-NOP3020\u003c\/strong\u003e tiene una longitud de punta de 2 mm, \u003cstrong\u003eISO-NOP3005\u003c\/strong\u003e tiene una longitud de punta de 0.5 mm). La respuesta es lineal en un amplio rango dinámico de concentración de NO. El diseño se basa en una sola fibra de carbono recubierta con la membrana selectiva de NO de WPI. Un límite de detección de aproximadamente 1 nM de NO hace que estos electrodos sean ideales para su uso en tejidos y microvasos.\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/current-time_b171e42e-2e35-4017-82b1-906d8bc47d95.jpg?v=1765946694\" alt=\"Sensor de óxido nítrico-Medición simultánea de fuerza\" width=\"631\" height=\"456\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eRespuesta de un sensor de NO de 7μm (ISO-NOP007) a adiciones sucesivas de NO (100nM). El recuadro muestra la linealidad del gráfico de calibración resultante.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/iso-no12_d98af86f-eb83-45de-9950-7c977e4b8730.jpg?v=1765946699\" alt=\"Sensor de óxido nítrico-cambios en la concentración de NO\" width=\"622\" height=\"344\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eMedición simultánea de fuerza (trazo superior) y cambios en la concentración de NO (trazo inferior) en (A) la arteria mesentérica superior de rata relajada con ACh y (B) una pequeña arteria humana relajada con ACh y SNAP. En esta arteria, la oxihemoglobina (oxyHb) revirtió parcialmente el aumento en la concentración de NO con solo un pequeño cambio en la fuerza. [U. Simonsen, et al., J. Physiol., 1999, \u003cstrong\u003e516\u003c\/strong\u003e: 271-282.]\u003c\/em\u003e\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/NO_Microsensors_IM.pdf\" target=\"_self\"\u003eManual de instrucciones de microsensores de NO\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable border=\"1\" cellspacing=\"0\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd\u003e \u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eISO-NOP007\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eISO-NOP3005\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eISO-NOP3020\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDiámetro exterior\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e 7 µm\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e30 μm\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e30 µm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eLongitud disponible\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e2 mm \u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e0.5 mm\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTiempo de respuesta\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e\u0026lt; 3 segundos \u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e\u0026lt; 3 segundos\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e\u0026lt; 3 segundos\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eLímite\/rango mínimo de detección\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e0.5 nM \u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e1 nM\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e1 nM\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSensibilidad nominal-Nuevo sensor\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e≥1 pA\/nM \u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e≥1.4 pA\/nM\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e≥1.5 pA\/nM\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eDeriva de línea base\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003eninguno \u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003eninguno\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e ninguno\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eVoltaje de Poise\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e865 mV \u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e865 mV\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e865 mV \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eCorriente típica de línea base en reposo, 25°C\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e300 pA \u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e1000 pA\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e500 pA \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRango aceptable de línea base\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e200-1500 pA \u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e150-3500 pA\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003e500-5000 pA \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eTiempo de polarización\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003eMás de 1 hora \u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003eMás de 1 hora\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"left\"\u003eMás de 1 hora \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c!-- \/section:specifications --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003eDantas, B. P. V, Ribeiro, T. P., Assis, V. L., Furtado, F. F., Assis, K. S., Alves, J. S., … Braga, V. A. (2014). Vasorelajación inducida por una nueva naftoquinona-oxima está mediada por la vía NO-sGC-cGMP. \u003ci\u003eMolecules (Basel, Switzerland)\u003c\/i\u003e, \u003ci\u003e19\u003c\/i\u003e(7), 9773–9785. \u003ca href=\"https:\/\/doi.org\/10.3390\/molecules19079773\"\u003ehttps:\/\/doi.org\/10.3390\/molecules19079773\u003c\/a\u003e  \u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"7 um, 2 mm","offer_id":42266182320218,"sku":"ISO-NOP007","price":1122.0,"currency_code":"USD","in_stock":true},{"title":"30 um, 0.5 mm","offer_id":42266182352986,"sku":"ISO-NOP3005","price":1282.0,"currency_code":"USD","in_stock":true},{"title":"30 um, 2 mm","offer_id":42266182385754,"sku":"ISO-NOP3020","price":1250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/iso_nop3005_12b90198-38fa-4fc3-97ec-a6885a87f0bb.jpg?v=1766398280"},{"product_id":"var-2973-iso-nopf-flexible-nitric-oxide-sensor","title":"Sensor flexible de óxido nítrico ISO-NOPF","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003e¡Sensor único y flexible de NO! Diseñado para arterias, microvasos, aplicaciones in vivo y aplicaciones similares\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ca href=\"\/es\/var-3422-snap-s-nitroso-n-acetyl-d-penicillamine\" tabindex=\"0\"\u003e\u003cspan style=\"font-size: 14pt;\" class=\"pdf-button\"\u003e¡No olvide el SNAP!\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExcelente selectividad para NO\u003c\/li\u003e\n\u003cli\u003eTiempo de respuesta rápido\u003c\/li\u003e\n\u003cli\u003eAltamente sensible\u003c\/li\u003e\n\u003cli\u003ePara uso con \u003cstrong\u003e\u003ca href=\"\/es\/tbr4100-four-channel-free-radical-analyzer\"\u003eTBR4100\u003c\/a\u003e\u003c\/strong\u003e y \u003cstrong\u003e\u003ca href=\"\/es\/tbr1025-one-channel-free-radical-analyzer\"\u003eTBR1025\u003c\/a\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eRequiere cable \u003ca href=\"\/es\/91580-microsensor-adapter-cable\"\u003e\u003cstrong\u003e91580\u003c\/strong\u003e\u003c\/a\u003e (se vende por separado)\u003c\/li\u003e\n\u003cli\u003eLímite mínimo de detección: 0.2 nM\u003c\/li\u003e\n\u003cli\u003eElija diámetro, longitud y forma\u003c\/li\u003e\n\u003cli\u003ePaquete\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003ePaquete de 2 ISO-NOPF200\u003c\/li\u003e\n\u003cli\u003ePaquete de 2 ISO-NOPF100\u003c\/li\u003e\n\u003cli\u003ePaquete de 2 ISO-NOPF500-CXX\u003c\/li\u003e\n\u003cli\u003ePaquete de 2 ISO-NOPF200-L10\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNota: Se requieren 3 días para pruebas antes del envío.\u003c\/p\u003e\n\u003ch2\u003eOpciones\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #0081c2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eCódigo de pedido\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003e\u003cspan class=\"choice\"\u003eLongitud de la punta\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003e\u003cspan class=\"choice\"\u003eDiámetro de la punta\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003e\u003cspan class=\"choice\"\u003eForma\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003e\u003cspan class=\"choice\"\u003ePaquete de\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: center; background-color: #e4e4e4;\"\u003e\n\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003eISO-NOPF100\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-5 mm\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e100 µm\u003c\/td\u003e\n\u003ctd\u003eRecto\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd style=\"background-color: #ffffff; text-align: left;\"\u003e\u003cstrong\u003eISO-NOPF200\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"background-color: #ffffff; text-align: center;\"\u003e1-5 mm\u003c\/td\u003e\n\u003ctd style=\"background-color: #ffffff; text-align: center;\"\u003e200 µm \u003c\/td\u003e\n\u003ctd style=\"background-color: #ffffff; text-align: center;\"\u003eRecto \u003c\/td\u003e\n\u003ctd style=\"background-color: #ffffff; text-align: center;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eISO-NOPF200-L10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 10 mm\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 200 µm\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eForma en L \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISO-NOPF100-Lxx\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-10 mm\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e 100 µm\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eForma en L\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eISO-NOPF200-Lxx\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-10 mm\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e200 µm\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eForma en L\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMás \u003ca href=\"\/es\/products\/instruments\/analyzers\/analyzers\/biosensors\/nitric-oxide-sensors\" rel=\"noopener\" target=\"_blank\"\u003esensores de óxido nítrico\u003c\/a\u003e \u003c\/p\u003e\n\u003ch2\u003eBeneficios\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSensor flexible, casi irrompible\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\nMedición de óxido nítrico \u003cem\u003ein vivo\u003c\/em\u003e \u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg alt=\"Sensor flexible de óxido nítrico\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ISO_NOPF200_Nitr_4ede60d98772d_sml_8861ffdc-2d28-4656-8b6e-4f2ba390db9e.jpg?v=1765946709\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003eLos electrodos \u003cstrong\u003eISO-NOPF\u003c\/strong\u003e están disponibles en diámetros de 100 µm, 200 µm y 500 µm. Utilizando los últimos avances en nanotecnología y ciencia de materiales, los científicos del Laboratorio de Sensores de WPI han creado estos sensores de NO completamente flexibles y prácticamente irrompibles. Los nuevos sensores se basan en un elemento sensor de NO de grafito compuesto combinado con un electrodo de referencia. La superficie del sensor está recubierta con una membrana selectiva de NO única y multicapa. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSensor único y flexible de NO\u003cstrong\u003e\u003cimg align=\"right\" height=\"182\" width=\"252\" alt=\"Gráfico in vivo\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/invivograph.jpg\" style=\"float: right; margin: 5px;\"\u003e\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp\u003eDiseñado para arterias, microvasos, aplicaciones in vivo y aplicaciones similares. El gráfico (a la derecha) muestra la respuesta del \u003cstrong\u003eISO-NOPF\u003c\/strong\u003e al NO.\u003c\/p\u003e\n\u003ch2\u003eDiseño\u003c\/h2\u003e\n\u003cp\u003eEstos sensores se basan en un elemento sensor de NO de grafito compuesto combinado con un electrodo de referencia. La superficie del sensor está recubierta con una membrana selectiva de NO única y multicapa.\u003c\/p\u003e\n\u003ch2\u003eSelectividad de los sensores de NO de WPI\u003c\/h2\u003e\n\u003cp\u003eEl sensor ideal de NO debe ser insensible a otras especies reactivas que probablemente estén presentes en el entorno de medición. El sensor convencional de NO de fibra de carbono recubierto con Nafion muestra una gran respuesta a dichas especies. La tecnología única de sensores de NO de WPI utiliza una membrana superficial novedosa que amplifica la respuesta al NO mientras elimina las respuestas a una amplia gama de especies reactivas, incluyendo nitrito, ácido ascórbico, peróxido de hidrógeno, catecolaminas y mucho más.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNOTA\u003c\/strong\u003e: ISO-NOPF200 es un sensor de 5 mm de largo, con longitudes personalizadas disponibles (1, 2, 3, 4 mm). Al pedir longitudes personalizadas, use el número de pieza \u003cstrong\u003eISO-NOPF200-CXX\u003c\/strong\u003e y reemplace el \u003cstrong\u003eXX\u003c\/strong\u003e con la longitud deseada. Por ejemplo, si desea una punta de sensor flexible de 1 mm, el número de pieza debe ser \u003cstrong\u003eISO-NOPF200-C01\u003c\/strong\u003e. Este sensor se puede pedir en las siguientes longitudes personalizadas: 1 mm, 2 mm, 3 mm o 4 mm. Seleccione su opción en la lista desplegable antes de realizar su pedido.\u003c\/p\u003e\n\u003cp\u003eEl \u003cstrong\u003eISO-NOPF500\u003c\/strong\u003e es un sensor de óxido nítrico diseñado como los sensores secos de fibra de carbono \u003ca href=\"\/es\/var-2973-iso-nopf-flexible-nitric-oxide-sensor\"\u003e\u003cstrong\u003eISO-NOPF\u003c\/strong\u003e \u003c\/a\u003e, sin embargo, funciona como un sensor tradicional \u003ca href=\"\/es\/iso-nop-nitric-oxide-sensor-2mm\"\u003e\u003cstrong\u003eISO-NOP\u003c\/strong\u003e \u003c\/a\u003ede 2mm. El sensor se puede pedir en una variedad de longitudes de 5 a 10mm. Incorpora la tecnología propietaria de electrodos combinados de WPI, en la que el elemento sensor de óxido nítrico y el electrodo de referencia separado están encerrados dentro de un diseño de sensor único y protegido. \u003c\/p\u003e\n\u003cp\u003eEl \u003ca href=\"\/es\/iso-nop-nitric-oxide-sensor-2mm\"\u003e\u003cstrong\u003eISO-NOP\u003c\/strong\u003e \u003c\/a\u003efue el sensor original de óxido nítrico, ideal para cultivos celulares, suspensiones celulares y muchas otras aplicaciones. El nuevo \u003cstrong\u003eISO-NOPF500 \u003c\/strong\u003epuede usarse de la misma manera, pero ofrece varias ventajas:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNo requiere mangas ni soluciones de llenado\u003c\/li\u003e\n\u003cli\u003eFlexible y duradero, como otros \u003ca href=\"\/es\/var-2973-iso-nopf-flexible-nitric-oxide-sensor\"\u003e\u003cstrong\u003eISO-NOPF\u003c\/strong\u003e \u003c\/a\u003esensores\u003c\/li\u003e\n\u003cli\u003eAlta sensibilidad para un tiempo de respuesta rápido–diez veces más sensible que el \u003ca href=\"\/es\/iso-nop-nitric-oxide-sensor-2mm\"\u003e\u003cstrong\u003eISO-NOP\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePuede usarse en condiciones ácidas\u003c\/li\u003e\n\u003cli\u003ePunta de sensor más larga que el \u003ca href=\"\/es\/iso-nop-nitric-oxide-sensor-2mm\"\u003e\u003cstrong\u003eISO-NOP\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eRango lineal más amplio que el \u003ca href=\"\/es\/iso-nop-nitric-oxide-sensor-2mm\"\u003e\u003cstrong\u003eISO-NOP\u003c\/strong\u003e \u003c\/a\u003e(el rango depende de la longitud de la punta del sensor)\u003c\/li\u003e\n\u003cli\u003eCalibración con el método SNAP o Nitrito\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNOTA\u003c\/strong\u003e: Al pedir longitudes personalizadas, use el número de pieza \u003cstrong\u003eISO-NOPF500-CXX\u003c\/strong\u003e y reemplace \u003cstrong\u003eXX\u003c\/strong\u003e con la longitud deseada. Por ejemplo, si desea una punta de sensor flexible de 10mm, el número de pieza debe ser \u003cstrong\u003eISO-NOPF500-C10\u003c\/strong\u003e. Este sensor se puede pedir en las siguientes longitudes personalizadas: 5mm, 6mm, 7mm, 8mm, 9mm o 10mm. \u003c\/p\u003e\n\u003ch2\u003eSensor en forma de L\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"Sensor de óxido nítrico en forma de L\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ISO_NOPF200L10.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003eEl \u003cstrong\u003eISO-NOPF200-L10\u003c\/strong\u003e es un sensor de óxido nítrico único en forma de L diseñado específicamente para su uso en estudios de baño de tejidos y aplicaciones similares. La forma del sensor ha sido diseñada para facilitar la colocación del electrodo dentro del lumen del vaso tisular bajo estudio. El \u003cstrong\u003eISO-NOPF200-L10\u003c\/strong\u003e tiene una punta flexible (diámetro de 200 µm).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/NO_Microsensors_IM.pdf\" target=\"_self\"\u003eManual de instrucciones NO Microsensores\u003c\/a\u003e\u003c\/p\u003e\r\n\u003ch2\u003eVídeo\u003c\/h2\u003e\r\nCloruro de cobre\r\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/DgP0Riv9eS8\" width=\"560\" height=\"315\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable border=\"1\" cellspacing=\"0\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd\u003e \u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eISO-NOPF-100\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eISO-NOPF-200\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eISO-NOPF200-L10\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003e\u003cstrong\u003eISO-NOPF500-CXX\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDiámetro exterior\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e100 μm\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e200 μm\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e200 µm\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e\u003cspan\u003e500 μm\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eLongitud disponible\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e1-5 mm (la longitud del sensor varía en 1 mm \u003cbr\u003e incrementos - 1 mm, 2 mm, 3 mm...)\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e1-5 mm (la longitud del sensor varía en 1 mm \u003cbr\u003e incrementos - 1 mm, 2 mm, 3 mm...)\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e10 mm\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e\n\u003cspan\u003e5-10mm (la longitud del sensor varía en 1 mm \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eincrementos - 1 mm, 2 mm, 3 mm...)\u003c\/span\u003e\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTiempo de respuesta\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e \u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e\u0026lt; 5 segundos\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e\u0026lt; 5 segundos\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e\u003cspan\u003e\u0026lt; 10 segundos\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eLímite\/rango mínimo de detección\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e0.2 nM \u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e0.2 nM\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e0.2 nM\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e\u003cspan\u003e0.2 nM\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSensibilidad nominal - Sensor nuevo\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e≥10 pA\/nM \u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e≥20 pA\/nM\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e≥50 pA\/nM\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e\u003cspan\u003e≥20 pA\/nM\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eDeriva de línea base\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003eninguno \u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003eninguno\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003eninguno\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e\u003cspan\u003eninguno\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eVoltaje de polarización\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e865 mV \u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e865 mV\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e865 mV\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e\u003cspan\u003e865 mV\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eCorriente típica en línea base en reposo, 25°C\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e 2000 pA\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e2500 pA\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e3500 pA\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e\u003cspan\u003e5000 pA\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRango aceptable de línea base\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e500-8000 pA \u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e500-8000 pA\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e500-8000 pA\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e\u003cspan\u003e3000-25000 pA\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eTiempo de polarización\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e2+ horas \u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e2+ horas\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e8+ horas\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" align=\"right\"\u003e\u003cspan\u003e8+ horas\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cdiv\u003e\u003cspan style=\"text-align: -webkit-right; background-color: #e6e6e6;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c!-- \/section:specifications --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eH. Lob, A.C. Rosenkranz, T. Breitenbach, R. Berkels, G. Drummond, R. Roesen\u003c\/strong\u003e \"Acciones antioxidantes y de conservación de óxido nítrico de dihidropiridinas e inhibidores de la ECA difieren en células endoteliales humanas\" \u003cspan style=\"font-style: italic;\"\u003eInternational J of Experimental and Clinical Pharmacology\u003c\/span\u003e 76. 2008:\u003c\/p\u003e\r\n\u003cp\u003eDiferencias en cepas murinas en la angiogénesis inflamatoria de heridas internas en diabetes. \u003cb\u003e(2017).\u003c\/b\u003e \u003ci\u003eBiomedicine \u0026amp; Pharmacotherapy\u003c\/i\u003e, \u003ci\u003e86\u003c\/i\u003e, 715–724.  \u003ca href=\"https:\/\/doi.org\/10.1016\/J.BIOPHA.2016.11.146\"\u003ehttps:\/\/doi.org\/10.1016\/J.BIOPHA.2016.11.146\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003eMocca, B., Yin, D., Gao, Y., \u0026amp; Wang, W. (2015).\u003c\/b\u003e El óxido nítrico producido por Moraxella catarrhalis tiene roles duales en la patogenicidad y eliminación de la infección en cocultivos de células bacterianas y hospedadoras. \u003ci\u003eNitric Oxide\u003c\/i\u003e, \u003ci\u003e51\u003c\/i\u003e, 52–62. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.niox.2015.10.001\"\u003ehttps:\/\/doi.org\/10.1016\/j.niox.2015.10.001\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003eCho, Y., Park, Y. M., Barate, A. K., Park, S.-Y., Park, H. J., Lee, M. R., … Hahn, T.-W. (2015).\u003c\/b\u003e El papel de rpoS, hmp y ssrAB en Salmonella enterica Gallinarum y evaluación de un mutante con triple deleción como candidato a vacuna viva en gallinas ponedoras Lohmann. \u003ci\u003eJournal of Veterinary Science\u003c\/i\u003e, \u003ci\u003e16\u003c\/i\u003e(2), 187–194. Recuperado de \u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/25549217\"\u003ehttp:\/\/www.ncbi.nlm.nih.gov\/pubmed\/25549217\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003eOrellano, L. A. A., Almeida, S. A., Campos, P. P., \u0026amp; Andrade, S. P. (2015).\u003c\/b\u003e Efectos angiopreventivos versus angiopromotores del alopurinol en el modelo de esponja murina. \u003ci\u003eMicrovascular Research\u003c\/i\u003e, \u003ci\u003e101\u003c\/i\u003e, 118–126. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.mvr.2015.07.003\"\u003ehttps:\/\/doi.org\/10.1016\/j.mvr.2015.07.003\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003eBradley, S. A., \u0026amp; Steinert, J. R. (2015).\u003c\/b\u003e Caracterización y comparación de perfiles temporales de liberación de donantes generadores de óxido nítrico. \u003ci\u003eJournal of Neuroscience Methods\u003c\/i\u003e, \u003ci\u003e245\u003c\/i\u003e, 116–124. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.jneumeth.2015.02.024\"\u003ehttps:\/\/doi.org\/10.1016\/j.jneumeth.2015.02.024\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003eLiu, S., Gu, T., Fu, J., Li, X., Chronakis, I. S., \u0026amp; Ge, M. (2014).\u003c\/b\u003e Nanopartículas híbridas de puntos cuánticos y polieter hiperramificado para la entrega y detección en tiempo real de óxido nítrico. \u003ci\u003eMaterials Science and Engineering: C\u003c\/i\u003e, \u003ci\u003e45\u003c\/i\u003e, 37–44. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.msec.2014.08.070\"\u003ehttps:\/\/doi.org\/10.1016\/j.msec.2014.08.070\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003eAraújo, F. A., Rocha, M. A., Capettini, L. S. A., Campos, P. P., Ferreira, M. A. N. D., Lemos, V. S., \u0026amp; Andrade, S. P. (2013).\u003c\/b\u003e El inhibidor de la 3-hidroxi-3-metilglutaril coenzima A reductasa (fluvastatina) disminuye la angiogénesis inflamatoria en ratones. \u003ci\u003eAPMIS\u003c\/i\u003e, \u003ci\u003e121\u003c\/i\u003e(5), 422–430. \u003ca href=\"https:\/\/doi.org\/10.1111\/apm.12031\"\u003ehttps:\/\/doi.org\/10.1111\/apm.12031\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003eDiniz, T., Pereira, A., Capettini, L., Santos, M., Nagem, T., Lemos, V., \u0026amp; Cortes, S. (2013).\u003c\/b\u003e Mecanismo del efecto vasodilatador de xantonas mono-oxigenadas: un estudio de relación estructura-actividad. \u003ci\u003ePlanta Medica\u003c\/i\u003e, \u003ci\u003e79\u003c\/i\u003e(16), 1495–1500. \u003ca href=\"https:\/\/doi.org\/10.1055\/s-0033-1350803\"\u003ehttps:\/\/doi.org\/10.1055\/s-0033-1350803\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003eRaithel, M., Hagel, A. F., Zopf, Y., Bijlsma, P. B., de Rossi, T. M., Gabriel, S., … Konturek, P. C. (2012).\u003c\/b\u003e Análisis de la liberación inmediata ex vivo de óxido nítrico de la mucosa colónica humana en alergia gastrointestinal, enfermedad inflamatoria intestinal y controles. \u003ci\u003eJournal of Physiology and Pharmacology : An Official Journal of the Polish Physiological Society\u003c\/i\u003e, \u003ci\u003e63\u003c\/i\u003e(4), 317–325. Recuperado de \u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/23070080\"\u003ehttp:\/\/www.ncbi.nlm.nih.gov\/pubmed\/23070080\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003eAraújo, F. A., Rocha, M. A., Ferreira, M. A., Campos, P. P., Capettini, L. S., Lemos, V. S., \u0026amp; Andrade, S. P. (2011).\u003c\/b\u003e La angiogénesis inflamatoria intraperitoneal inducida por implantes se atenúa con fluvastatina. \u003ci\u003eClinical and Experimental Pharmacology and Physiology\u003c\/i\u003e, \u003ci\u003e38\u003c\/i\u003e(4), 262–268. \u003ca href=\"https:\/\/doi.org\/10.1111\/j.1440-1681.2011.05496.x\"\u003ehttps:\/\/doi.org\/10.1111\/j.1440-1681.2011.05496.x\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003eTang, X., Chen, J., Wang, W.-H., Liu, T.-W., Zhang, J., Gao, Y.-H., … Zheng, H.-L. (2011).\u003c\/b\u003e Cambios en la producción de óxido nítrico durante el crecimiento de Microcystis aeruginosa. \u003ci\u003eEnvironmental Pollution\u003c\/i\u003e, \u003ci\u003e159\u003c\/i\u003e(12), 3784–3792. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.envpol.2011.06.042\"\u003ehttps:\/\/doi.org\/10.1016\/j.envpol.2011.06.042\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003eAndrews, A. M., Jaron, D., Buerk, D. G., Kirby, P. L., \u0026amp; Barbee, K. A. (2010). \u003c\/b\u003eMedición directa y en tiempo real del óxido nítrico producido por cizallamiento en células endoteliales in vitro. \u003ci\u003eNitric Oxide\u003c\/i\u003e, \u003ci\u003e23\u003c\/i\u003e(4), 335–342. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.niox.2010.08.003\"\u003ehttps:\/\/doi.org\/10.1016\/j.niox.2010.08.003\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003eMantione, K. J., \u0026amp; Stefano, G. B. (2004). \u003c\/b\u003eUna sonda de óxido nítrico en tiempo real subnanomolar: liberación in vivo de óxido nítrico en el corazón. \u003ci\u003eMedical Science Monitor : International Medical Journal of Experimental and Clinical Research\u003c\/i\u003e, \u003ci\u003e10\u003c\/i\u003e(4), MT47-9. Recuperado de \u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/15039652\"\u003ehttp:\/\/www.ncbi.nlm.nih.gov\/pubmed\/15039652\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"1-5 mm, 200 um","offer_id":42266182484058,"sku":"ISO-NOPF200","price":1375.0,"currency_code":"USD","in_stock":true},{"title":"1-5 mm, 100 um","offer_id":42266182516826,"sku":"ISO-NOPF100","price":1525.0,"currency_code":"USD","in_stock":true},{"title":"10 mm, 200 um","offer_id":42266182549594,"sku":"ISO-NOPF200-L10","price":1792.0,"currency_code":"USD","in_stock":true},{"title":"1-10 mm, 100 um","offer_id":42266182582362,"sku":"ISO-NOPF100-LXX","price":1675.0,"currency_code":"USD","in_stock":true},{"title":"1-10 mm, 200 um","offer_id":42266182615130,"sku":"ISO-NOPF200-LXX","price":1550.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/iso_nopf500_nitr_4e8ef75404efc_dc9bd3c4-5392-4fa5-ace9-fa5d40ac2ee8.jpg?v=1766398305"},{"product_id":"iso-oxy-2-iso-oxy-2-oxygen-sensor-2mm","title":"Sensor de oxígeno ISO-OXY-2 - 2mm","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eManga de membrana de polímero permeable al gas que bloquea líquidos, iones y partículas\u003c\/li\u003e\n\u003cli\u003eElectrodo de referencia incorporado\u003c\/li\u003e\n\u003cli\u003ePara uso con \u003cstrong\u003eApollo1000\u003c\/strong\u003e, \u003cstrong\u003eApollo4000\u003c\/strong\u003e, \u003ca href=\"\/es\/tbr4100-four-channel-free-radical-analyzer\"\u003e\u003cstrong\u003eTBR4100\u003c\/strong\u003e\u003c\/a\u003e y \u003ca href=\"\/es\/tbr1025-one-channel-free-radical-analyzer\"\u003e\u003cstrong\u003eTBR1025\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eTiempo de respuesta: \u0026lt; 10s\u003c\/li\u003e\n\u003cli\u003eLímite de detección: 0.1% a 100%\u003c\/li\u003e\n\u003cli\u003eDeriva: \u0026lt;1%\/min\u003c\/li\u003e\n\u003cli\u003ePaquete de 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBeneficios\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSensor de oxígeno tipo Clark con punta de 2 mm, puede usarse para medición de O\u003csub\u003e2\u003c\/sub\u003e en volúmenes muy pequeños\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCultivo celular, suspensiones celulares\u003c\/li\u003e\n\u003cli\u003eMediciones de tejido celular\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eEl \u003cstrong\u003eISO-OXY-2\u003c\/strong\u003e es un sensor de acero inoxidable de 2.0 mm, con mangas de membrana reemplazables (5378) y un electrolito interno recargable (#\u003ca href=\"\/es\/7326-sys-iso2-filling-solution\"\u003e7326\u003c\/a\u003e).\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/2mmkit_97e1079d-0e4d-42f1-982b-48ca3a6d8731.jpg?v=1765946747\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/2mmkit_97e1079d-0e4d-42f1-982b-48ca3a6d8731.jpg?v=1765946747\" alt=\"Los biosensores de 2 mm vienen con piezas de repuesto\" width=\"377\" height=\"212\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNOTA\u003c\/strong\u003e: Los biosensores de 2 mm vienen con dos mangas de membrana de repuesto, jeringa de 1 cc, aguja MicroFil MF28G67 y 10 mL de solución de llenado (#\u003ca href=\"\/es\/7326-sys-iso2-filling-solution\"\u003e7326\u003c\/a\u003e).\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ISO-OXY-2-performance_1ef41956-359e-4071-ae50-1c8a07900f28.jpg?v=1765946753\" alt=\"Resultados de rendimiento del ISO-OXY-2\"\u003e\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ISO-OXY-2_IMs.pdf\" target=\"_self\"\u003e\u003cstrong\u003eManual de instrucciones ISO-OXY-2\u003c\/strong\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/Xy_vTV1v-Z0\" width=\"600\" height=\"450\" frameborder=\"0\" data-mce-fragment=\"1\"\u003e\u003c\/iframe\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAPLICACIÓN\u003c\/td\u003e\n\u003ctd\u003eCultivos celulares, suspensiones celulares\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eDIÁMETRO DEL SENSOR\u003c\/td\u003e\n\u003ctd\u003e2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTIEMPO DE RESPUESTA\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 SEG (90%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eLÍMITE DE DETECCIÓN\u003c\/td\u003e\n\u003ctd\u003e0.1 % a 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDERIVA\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1%\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eSENSIBILIDAD\u003c\/td\u003e\n\u003ctd\u003eNo disponible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eINTERFERENCIA FISIOLÓGICA\u003c\/td\u003e\n\u003ctd\u003eNinguna\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eX. Liu, C. Cheng, N. Zorko, S. Cronin, Y.R. Chen, J.L. Zweier\u003c\/strong\u003e \"Modulación bifásica del catabolismo vascular del óxido nítrico por oxígeno\" \u003cspan style=\"font-style: italic;\"\u003eAm J Phhsiol Heart circ Physiol\u003c\/span\u003e 287. 2004: H2421-H2426\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOlson, K. R., Gao, Y., DeLeon, E. R., Arif, M., Arif, F., Arora, N., \u0026amp; Straub, K. D. (2017).\u003c\/b\u003e Catalasa como oxidorreductasa de sulfuro-sulfuro: un regulador antiguo (¿y moderno?) de especies reactivas de azufre (RSS). \u003ci\u003eRedox Biology\u003c\/i\u003e, \u003ci\u003e12\u003c\/i\u003e, 325–339. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.redox.2017.02.021\"\u003ehttps:\/\/doi.org\/10.1016\/j.redox.2017.02.021\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHirai, T., Osamura, T., Ishii, M., \u0026amp; Arai, H. (2016).\u003c\/b\u003e Expresión de múltiples isoformas de citocromo c oxidasa cbb3 mediante combinaciones de múltiples isosubunidades en Pseudomonas aeruginosa. \u003ci\u003eProceedings of the National Academy of Sciences of the United States of America\u003c\/i\u003e, \u003ci\u003e113\u003c\/i\u003e(45), 12815–12819. \u003ca href=\"https:\/\/doi.org\/10.1073\/pnas.1613308113\"\u003ehttps:\/\/doi.org\/10.1073\/pnas.1613308113\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePark, Y. M., Lee, H. J., Jeong, J.-H., Kook, J.-K., Choy, H. E., Hahn, T.-W., \u0026amp; Bang, I. S. (2015).\u003c\/b\u003e La suplementación con aminoácidos de cadena ramificada promueve el crecimiento aeróbico de Salmonella Typhimurium bajo condiciones de estrés nitrosativo. \u003ci\u003eArchives of Microbiology\u003c\/i\u003e, \u003ci\u003e197\u003c\/i\u003e(10), 1117–1127. \u003ca href=\"https:\/\/doi.org\/10.1007\/s00203-015-1151-y\"\u003ehttps:\/\/doi.org\/10.1007\/s00203-015-1151-y\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266182713434,"sku":"ISO-OXY-2","price":1092.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/iso-oxy-2_1_9cfae048-4e15-49e1-88de-03c55c9d8a8e.jpg?v=1766398349"},{"product_id":"lab-trax-4-labtrax-4-channel-data-acquisition","title":"Adquisición de Datos LabTrax de 4 Canales","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eResolución de 16 bits\u003c\/li\u003e\n\u003cli\u003eIncluye software LabScribe\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequiere\u003c\/strong\u003e \u003ca href=\"\/es\/var-2851-bnc-to-bnc-cable\"\u003eCables BNC-BNC \u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003ePara más información sobre las funciones disponibles en el software \u003cstrong\u003eLabScribe\u003c\/strong\u003e para \u003cstrong\u003eLab-Trax\u003c\/strong\u003e, \u003ca href=\"\/es\/blog\/post\/labscribe-software-for-labtrax\" target=\"_blank\" rel=\"noopener\"\u003evea el artículo\u003c\/a\u003e.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003eManuales\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/TBR_IM.pdf\" target=\"_self\"\u003eManual de instrucciones TBR\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/lab-trax-416-im-102407.pdf\"\u003eHardware de adquisición de datos Lab-Trax-4\/16 de 4 canales\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e  \u003c\/p\u003e\r\n\u003ch2\u003eSoftware para LabScribe (anteriormente LabTrax)\u003c\/h2\u003e\r\n\u003cp\u003e\u003cstrong\u003eLabScribe v4:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eSistema operativo Windows: Win10\/Win 11\u003cbr\u003eMac OS: OSX 10.13 y superior\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eHardware de computadora:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eEspecificaciones mínimas: Procesador Dual Core, memoria de 4GB o más.\u003cbr\u003eEspecificaciones recomendadas: Procesador Quad Core de 64 bits, memoria de 8GB o más.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eHardware de computadora para Seguimiento Ocular:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eEspecificaciones recomendadas: CPU Intel i7 o superior, 16GB de RAM, unidad de estado sólido de 256 GB, tarjeta gráfica\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eTabletas:\u003c\/strong\u003e\u003cbr\u003eTabletas que ejecutan la versión completa de Windows 8 o Windows 10, como Surface Pro, Dell Venue Pro, Asus Transformer Book, VivoTad, Toshiba Encore, etc. (Windows RT no es compatible)\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eCaracterísticas del software LabScribe v4\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eLa última versión, LabScribe incluye varias funciones adicionales fáciles de usar para adquisición, mejoras en la interfaz de usuario, potentes capacidades de análisis y rutinas automatizadas de post-procesamiento. \u003cbr\u003e• Macro: LabScribe 4 añade la capacidad de automatizar tareas en LabScribe usando macros.\u003cbr\u003e• Constructor de Experimentos: Las macros pueden usarse como constructor de experimentos para estudios psicológicos.\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eMuestra imágenes, videos y otros medios\u003c\/li\u003e\r\n\u003cli\u003eMuestra texto y colores\u003c\/li\u003e\r\n\u003cli\u003eUsa Hojas de cálculo\u003c\/li\u003e\r\n\u003cli\u003eControla el Estimulador y las salidas digitales\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e• Usa Macros para grabar los datos en múltiples archivos, esto reduce el tamaño del archivo facilitando el análisis de los datos.\u003cbr\u003e• Importar y aplicar configuraciones de un archivo a otro. Esto permite al usuario aplicar las mismas configuraciones a un conjunto de archivos de datos que fueron grabados.\u003cbr\u003e• Diálogo simplificado de Eventos y AutoFind\u003cbr\u003e• Ocultar\/Mostrar marcas de imagen\u003cbr\u003e• Módulo Metabólico:\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eNueva pantalla en línea que simplifica la calibración.\u003c\/li\u003e\r\n\u003cli\u003eControla cintas de correr Woodway o Trackmaster\u003c\/li\u003e\r\n\u003cli\u003eControla el Ergómetro Lode\u003c\/li\u003e\r\n\u003cli\u003eControla bicicletas de entrenamiento ANT+ FEC, como la Watt Bike.\u003c\/li\u003e\r\n\u003cli\u003eGráficos en línea para cálculos metabólicos, como VO2, VCO2...\u003c\/li\u003e\r\n\u003cli\u003eOtras mejoras en módulos de análisis\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e• Captura de Video\u003cbr\u003e• Módulo de Análisis de Clasificación de Picos\u003cbr\u003e• Análisis de contracción linfática\u003cbr\u003e• Exportación de intervalo RR agregada al menú Avanzado-\u0026gt;ECG para cálculos de HRV usando Kubios\u003cbr\u003e• Seguimiento Ocular: Se agregó visualización de mapa de calor\u003cbr\u003e• Soporte para IX-GSR, iWire-AM, oxímetro de pulso USB, sistema ECG para ratón neonatal.\u003cbr\u003e• Función cruzada entre canales de tiempo, se agregó Tiempo a máximo, mínimo, para calcular el tiempo de tránsito, para medir la velocidad de la onda del pulso.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eDescargar: v4.345 (Instalador completo ~700M)\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"https:\/\/firebasestorage.googleapis.com\/v0\/b\/x-caregiver-recruiting.firebasestorage.app\/o\/wpi-pdf%2FLabScribe4_Mac.pkg?alt=media\u0026amp;token=6f57eb8f-697b-45d3-8412-654f54c6734c\"\u003eInstalador para Macintosh\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/firebasestorage.googleapis.com\/v0\/b\/x-caregiver-recruiting.firebasestorage.app\/o\/wpi-pdf%2FLabScribe4_Installer_WIN10.exe?alt=media\u0026amp;token=a75d440d-aba4-4c34-aa06-ae0961d6abc6\"\u003eInstalador para Windows (32 o 64 bits)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/Templates_LS4.zip\" target=\"_self\"\u003eArchivos de ejemplo\u003c\/a\u003e – Archivo ZIP que incluye manuales de hardware y software, SIN grabación de demostración, ejemplos de hojas de cálculo de concentración. (Templates_LS3.zip)\u003c\/p\u003e\r\n\u003cp\u003eNota: La instalación de los controladores generalmente es solo para departamentos de TI o para aplicaciones de investigación. Todos los instaladores del software LabScribe incluyen controladores autoextraíbles para sistemas operativos que incluyen Vista-Win10 y OS10.13 y superiores.  \u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eNúmero de entradas\u003c\/td\u003e\r\n\u003ctd\u003e4\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eResolución ADC\u003c\/td\u003e\r\n\u003ctd\u003e16 bits\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTasa máxima de muestreo\u003c\/td\u003e\r\n\u003ctd\u003e10,000 muestras \/ seg agregadas\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eConectores de entrada\u003c\/td\u003e\r\n\u003ctd\u003eBNC, 50 ohmios\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eImpedancia de Entrada\u003c\/td\u003e\r\n\u003ctd\u003e1M Ohm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eRango de Entrada\u003c\/td\u003e\r\n\u003ctd\u003e±10 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRuido del sistema\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 1mV (1 parte en 20,000)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eEntrada\/Salida digital\u003c\/td\u003e\r\n\u003ctd\u003e4 entradas 4 salidas\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFuente de energía\u003c\/td\u003e\r\n\u003ctd\u003eAlimentado por USB\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eCorriente de operación\u003c\/td\u003e\r\n\u003ctd\u003e100 mA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eInterfaz para PC\u003c\/td\u003e\r\n\u003ctd\u003eUSB 2.0\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eVoltaje máximo de entrada\u003c\/td\u003e\r\n\u003ctd\u003e±10 voltios (100 con sonda x10)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003eRequisitos recomendados para computadora:\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eWindows OS: Win10\u003c\/li\u003e\r\n\u003cli\u003eMac OS: OSX 10.13 y superior\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003eHardware de computadora para LabScribe:\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eEspecificaciones mínimas: Procesador Dual Core, memoria de 4GB o más.\u003c\/li\u003e\r\n\u003cli\u003eEspecificaciones recomendadas: Procesador Quad Core de 64 bits, memoria de 8GB o más.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003eHardware de computadora para Seguimiento Ocular:\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e Especificaciones recomendadas: CPU Intel i7 o superior, 16GB de RAM, unidad de estado sólido de 256 GB, tarjeta gráfica\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003eTabletas:\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eTabletas que ejecutan la versión completa de Windows 8 o Windows 10, como Surface Pro, Dell Venue Pro, Asus Transformer Book, VivoTad, Toshiba Encore, etc. (Windows RT no es compatible)\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266190577754,"sku":"LAB-TRAX-4","price":2300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/lab-trax-4_1_b98b7c91-4604-4219-baa2-299b16b94769.jpg?v=1766398524"},{"product_id":"nce-nerve-cuff-electrodes","title":"Electrodos para Manguito Nervioso","description":"\u003c!-- section:details --\u003e\n\u003cp\u003eNuestros electrodos de manguito nervioso pueden fabricarse según sus especificaciones. Vea todas las opciones que puede elegir. Por favor, utilice este formulario para crear un pedido. Un ejecutivo de cuenta de WPI revisará su solicitud y se pondrá en contacto con usted lo antes posible.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ca rel=\"noopener\" href=\"\/es\/pages\/concentric-nerve-cuff\" target=\"_blank\"\u003e\u003cspan style=\"“font-size: 14;\" class=\"button\"\u003eFormulario de pedido para manguito nervioso concéntrico\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ca rel=\"noopener\" href=\"\/es\/pages\/nerve-cuff-standard\" target=\"_blank\"\u003e\u003cspan style=\"“font-size: 14;\" class=\"button\"\u003eFormulario de pedido para manguito nervioso estándar\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ca rel=\"noopener\" href=\"\/es\/pages\/x-wide-contacts-nerve-cuff\" target=\"_blank\"\u003e\u003cspan style=\"“font-size: 14;\" class=\"button\"\u003eFormulario de pedido para manguitos nerviosos de contactos extra anchos\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/NCE_DS.pdf\"\u003eConsulte la hoja de datos actual de NCE\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePara experimentos agudos\/crónicos\u003c\/li\u003e\n\u003cli\u003eDe 1 a 24 sitios de electrodos\u003c\/li\u003e\n\u003cli\u003eAmplia gama de diámetros internos disponibles, desde 5 mm hasta tan pequeños como 56 µm\u003c\/li\u003e\n\u003cli\u003eElectrodos metálicos de platino, acero inoxidable y platino\/iridio\u003c\/li\u003e\n\u003cli\u003eArreglos de electrodos personalizables, incluyendo concéntricos y tri-bipolares\u003c\/li\u003e\n\u003cli\u003eAdaptable para conectarse con el sistema de adquisición de su elección\u003c\/li\u003e\n\u003cli\u003eAdecuado para investigación en roedores, felinos, aves y primates\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"p1\"\u003eConfiguraciones\u003c\/h2\u003e\n\u003cp class=\"p1\"\u003e\u003cimg align=\"right\" height=\"174\" width=\"233\" alt=\"Cómo configurar su electrodo de manguito nervioso\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/nce-electrodes4_94b2b7b9-b07a-46c7-9e94-417998638c9e.png?v=1765947253\" style=\"float: right;\"\u003eEstán disponibles muchas combinaciones personalizadas de diámetros internos y arreglos de contactos para manguitos nerviosos estándar, micro y nano.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003cp class=\"p1\"\u003e1 suturas opcionales\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e2 de 1 a 24 contactos (Platino, Platino\/Iridio o Acero Inoxidable)\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e3 longitud personalizada\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e4 diámetro personalizado\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e5 cables trenzados de acero inoxidable\u003c\/p\u003e\n\u003ch3 class=\"p1\"\u003eManguito Nervioso Estándar\u003c\/h3\u003e\n\u003cp class=\"p1\"\u003eEstán disponibles muchas combinaciones personalizadas de diámetros internos y arreglos de contactos.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cspan style=\"font-size: 1.17em;\"\u003eManguito Nervioso Tri-bipolar\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eEstán disponibles conjuntos complejos tripolares de grabación\/estimulación.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cimg height=\"133\" width=\"301\" alt=\"El manguito nervioso tripolar tiene 3 conjuntos de electrodos para grabación\/estimulación.\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/nce-electrodes2_c7a3f996-675e-4f00-9c02-1969007b6ac2.png?v=1765947259\"\u003e\u003c\/p\u003e\n\u003ch3 class=\"p1\"\u003eManguito Nervioso Concéntrico\u003c\/h3\u003e\n\u003cp class=\"p1\"\u003eLos electrodos concéntricos tienen múltiples contactos alrededor de un solo punto del nervio, permitiendo la grabación o estimulación en diferentes ubicaciones alrededor del mismo punto.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cimg height=\"143\" width=\"300\" alt=\"Los electrodos concéntricos tienen múltiples contactos alrededor de un solo punto del nervio, permitiendo la grabación o estimulación en diferentes ubicaciones alrededor del mismo punto.\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/nce-electrodes3_5534969e-24f0-42d9-9cd5-6be629313d74.png?v=1765947264\"\u003e\u003c\/p\u003e\n\u003ch3 class=\"p1\"\u003eManguitos Nerviosos con Contactos de Ancho X\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cimg align=\"right\" height=\"172\" width=\"299\" alt=\"Contactos de ancho x en estos electrodos de manguito nervioso\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/nce-x_wide-characteristics_med_01defeb3-be9f-43a9-874a-d25c7ba71434.jpg?v=1765947270\" style=\"float: right;\"\u003eContactos de cinta de platino extragrandes que maximizan el área de superficie del electrodo mientras mantienen la fiabilidad y personalización\u003c\/li\u003e\n\u003cli\u003eIdeal para cualquier estudio de estimulación eléctrica, especialmente aquellos que utilizan estimulación en KHz para bloquear la actividad de los nervios periféricos\u003c\/li\u003e\n\u003cli\u003eUmbrales más bajos y márgenes de seguridad aumentados le brindan nueva libertad para desarrollar paradigmas de estimulación aún más efectivos\u003c\/li\u003e\n\u003cli\u003eLas mismas características de mejora de fiabilidad que nuestros manguitos estándar, incluyendo uniones reforzadas y cables helicoidales especialmente diseñados, que proporcionan la mejor longevidad implantada en la industria\u003c\/li\u003e\n\u003cli\u003eEspecificaciones totalmente personalizables, incluyendo el espaciamiento de contactos, longitud del manguito y características del cable, con una amplia gama de diámetros internos disponibles desde más de 6 mm hasta 300 µm.\u003c\/li\u003e\n\u003cli\u003eConfigurable tanto para uso agudo como crónico\u003c\/li\u003e\n\u003cli\u003eOpciones de conector para cualquier sistema de estimulación o registro disponible\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLa utilidad clave de estos manguitos la proporciona la gran área de superficie de contacto, ideal para estudios que requieren niveles altos de corriente y cuando se usa estimulación eléctrica en kilohertz para lograr el bloqueo de la actividad en nervios periféricos. Las impedancias reducidas aseguran que la salida de las fuentes de estimulación no se atenúe, que no haya acumulación destructiva de carga y que se logre un bloqueo verdadero de la actividad nerviosa.\u003c\/p\u003e\n\u003ch2 class=\"p1\"\u003eEsterilización\u003c\/h2\u003e\n\u003cp class=\"p1\"\u003eLos manguitos nerviosos están hechos completamente de materiales autoclavables — caucho de silicona, teflón y acero inoxidable. Pueden ser autoclavados con vapor sin precauciones especiales. Si se prefiere la esterilización por gas (EtO), asegúrese de empacar los manguitos nerviosos en una bolsa permeable al gas y permitir un tiempo adecuado de desgasificación (al menos 48 horas) para asegurarse de que todos los gases tóxicos hayan sido desorbidos del caucho de silicona. \u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/NCE_IM.pdf\" target=\"_blank\"\u003eInstrucciones de uso\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:specifications --\u003e\n\u003ch2 class=\"Heading-1\"\u003eOpciones disponibles\u003c\/h2\u003e\n\u003ctable cellpadding=\"2\" cellspacing=\"0\" border=\"1\" style=\"border-width: 1px;\" class=\"Basic-Table TableOverride-1\" id=\"table001\"\u003e\n\u003ccolgroup\u003e \u003ccol class=\"_idGenTableRowColumn-1\"\u003e \u003ccol class=\"_idGenTableRowColumn-2\"\u003e \u003ccol class=\"_idGenTableRowColumn-3\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #0081c2;\" class=\"Basic-Table _idGenTableRowColumn-4\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-1\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-1\"\u003e\n\u003cp class=\"Body-text\"\u003e\u003cspan style=\"color: #ffffff;\" class=\"Bold CharOverride-3\"\u003eTipo de metal\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-2\"\u003e\n\u003cp class=\"Body-text\"\u003e\u003cspan style=\"color: #ffffff;\" class=\"Bold CharOverride-3\"\u003eDiámetro interior\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-5\"\u003e\n\u003ctd rowspan=\"3\" class=\"Basic-Table CellOverride-3\"\u003e\n\u003cp class=\"Body-text ParaOverride-4\"\u003e\u003cspan class=\"CharOverride-1\"\u003eEstándar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-4\"\u003e\n\u003cp class=\"Body-text\"\u003e\u003cspan class=\"CharOverride-1\"\u003e125μm trenzado de acero inoxidable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-4\"\u003e\n\u003cp class=\"Body-text\"\u003e\u003cspan class=\"CharOverride-1\"\u003e1.0 – 5.0mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-4\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-4\"\u003e\n\u003cp class=\"Body-text\"\u003e\u003cspan class=\"CharOverride-1\"\u003e100μm Platino\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-4\"\u003e\n\u003cp class=\"Body-text\"\u003e\u003cspan class=\"CharOverride-1\"\u003e1.0 – 2.0mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-4\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-4\"\u003e\n\u003cp class=\"Body-text\"\u003e\u003cspan class=\"CharOverride-1\"\u003e250μm Platino*\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-4\"\u003e\n\u003cp class=\"Body-text\"\u003e\u003cspan class=\"CharOverride-1\"\u003e2.0 – 5.0mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-5\"\u003e\n\u003ctd rowspan=\"2\" class=\"Basic-Table CellOverride-3\"\u003e\n\u003cp class=\"Body-text ParaOverride-4\"\u003e\u003cspan class=\"CharOverride-1\"\u003eMicro Cuff\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-4\"\u003e\n\u003cp class=\"Body-text\"\u003e\u003cspan class=\"CharOverride-1\"\u003e100μm Platino\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-4\"\u003e\n\u003cp class=\"Body-text\"\u003e\u003cspan class=\"CharOverride-1\"\u003e0.5 – 0.75mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-5\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-4\"\u003e\n\u003cp class=\"Body-text\"\u003e\u003cspan class=\"CharOverride-1\"\u003e50μm Platino\/Iridio\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-4\"\u003e\n\u003cp class=\"Body-text\"\u003e\u003cspan class=\"CharOverride-1\"\u003e0.3mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-6\"\u003e\n\u003ctd rowspan=\"2\" class=\"Basic-Table CellOverride-3\"\u003e\n\u003cp class=\"Body-text ParaOverride-4\"\u003e\u003cspan class=\"CharOverride-1\"\u003eNano Cuff\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-4\"\u003e\n\u003cp class=\"Body-text\"\u003e\u003cspan class=\"CharOverride-1\"\u003e25µm Platino\/Iridio\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-4\"\u003e\n\u003cp class=\"Body-text\"\u003e\u003cspan class=\"CharOverride-1\"\u003e160 - 250µm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-6\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-4\"\u003e\n\u003cp class=\"Body-text\"\u003e\u003cspan class=\"CharOverride-1\"\u003e12.5µm Platino\/Iridio\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-4\"\u003e\n\u003cp class=\"Body-text\"\u003e\u003cspan class=\"CharOverride-1\"\u003e56 - 140µm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"Body-text\"\u003e\u003cspan class=\"CharOverride-1\"\u003e* Recomendado para estimulación\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Heading-1\"\u003e \u003c\/p\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266217185370,"sku":"NCE","price":0.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/nce-electrodes_b6274b61-6e22-470f-80ad-9bc5f89966c7.jpg?v=1766398918"},{"product_id":"ptm23b05-platinum-iridium-metal-electrodes-profile-a","title":"Electrodos Metálicos de Platino Iridio Perfil A","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrodos de platino-iridio\u003c\/li\u003e\n\u003cli\u003ePara grabación crónica y microestimulación\u003c\/li\u003e\n\u003cli\u003ePaquete de 5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%;\" colspan=\"2\"\u003e\n\u003ch2\u003eVENTAJAS\u003c\/h2\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 11%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/lower-concomitant-impedance_b4808d9a-8e8c-42b3-8150-12b15d4feb45.jpg?v=1765947447\" alt=\"impedancia concomitante más baja\" width=\"100\" height=\"100\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: #0081c2;\"\u003eImpedancia Concomitante Más Baja\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eEsta sonda tiene una impedancia concomitante más baja en comparación con el tungsteno y el acero inoxidable.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 11%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/higher-charge-_transfer-capacity_4aad9dab-deee-4a86-82ad-23e604d434fa.jpg?v=1765947453\" alt=\"mayor capacidad de transferencia de carga\" width=\"100\" height=\"100\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: #0081c2;\"\u003eMayor Capacidad de Transferencia de Carga\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eLo que lo hace perfecto para microestimulación, los electrodos de Pt-Ir tienen una mayor capacidad de transferencia de carga en comparación con el tungsteno y el acero inoxidable.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 11%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/improved-electrochemical-stability_e0123693-cef1-4070-9740-7dc75ae209bf.jpg?v=1765947459\" alt=\"estabilidad electroquímica mejorada\" width=\"100\" height=\"100\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: #0081c2;\"\u003eEstabilidad Electroquímica Mejorada\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eEl Pt-Ir ofrece una estabilidad electroquímica mejorada en comparación con el tungsteno y el acero inoxidable.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 11%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/Perfect-microstimulation_73dfb894-1227-40fc-b55c-4c2715c670df.jpg?v=1765947465\" alt=\"Perfecto para microestimulación\" width=\"100\" height=\"100\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: #0081c2;\"\u003ePerfecto para Microestimulación\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003ePerfecto para microestimulación, con un rendimiento excelente que garantiza una estimulación segura incluso con sondas pequeñas.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 11%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/bend-_resistance_e9cce1e3-25b7-4948-8088-d1927ea0b2c6.jpg?v=1765947472\" alt=\"El contenido de iridio mejora la resistencia a la flexión\" width=\"100\" height=\"100\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: #0081c2;\"\u003eEl Contenido de Iridio Mejora la Resistencia a la Flexión\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eEl contenido de iridio en la aleación aumenta la dureza mecánica, lo que endurece el electrodo hasta el punto de que la resistencia a la flexión se acerca a la del tungsteno.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 11%;\" colspan=\"2\"\u003e\n\u003ch2\u003eCONSIDERACIONES\u003c\/h2\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 11%;\" colspan=\"2\"\u003e\n\u003ch3\u003e¿Está realizando grabaciones agudas o grabaciones crónicas no intensivas?\u003c\/h3\u003e\n\u003cp\u003ePodría usar una sonda de tungsteno en su lugar. El platino-iridio cuesta más que el tungsteno y el acero inoxidable, lo que lo hace menos deseable para grabaciones agudas y grabaciones crónicas no intensivas.\u003c\/p\u003e\n\u003ch3\u003e¿Realizará protocolos intensivos de estimulación?\u003c\/h3\u003e\n\u003cp\u003eLos protocolos intensivos de estimulación podrían hacer que las sondas de platino-iridio sean susceptibles a la corrosión y disolución.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cstrong style=\"font-size: 12px;\"\u003ePerfil de Platino Iridio A Tabla Comparativa\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable id=\"a1\" class=\"sortable\" border=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr bgcolor=\"#e4e4e4\"\u003e\n\u003cth\u003eArtículo\u003c\/th\u003e\n\u003cth\u003eLargo\u003c\/th\u003e\n\u003cth\u003eAislamiento\u003cbr\u003eGrosor\u003c\/th\u003e\n\u003cth\u003eCaña\u003cbr\u003eDiámetro\u003c\/th\u003e\n\u003cth\u003eNominal\u003cbr\u003eImpedancia\u003cbr\u003e±20%\u003c\/th\u003e\n\u003cth\u003eConsejo\u003cbr\u003eDiámetro\u003c\/th\u003e\n\u003cth\u003eUso típico\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePTM23B05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51mm\u003c\/td\u003e\n\u003ctd\u003e 3µ\u003c\/td\u003e\n\u003ctd\u003e0.231mm\u003c\/td\u003e\n\u003ctd\u003e0.5MΩ\u003c\/td\u003e\n\u003ctd\u003e2-3µ\u003c\/td\u003e\n\u003ctd\u003eRegistro de unidad simple y múltiple, estimulación, implante crónico\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUso típico\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRegistro de unidad simple y múltiple, estimulación, implantes crónicos\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/es\/index.php?src=blog\u0026amp;srctype=detail\u0026amp;refno=19\u0026amp;category=Product%20Information\"\u003e\u003cstrong\u003eVer Guía de Selección de Microelectrodos Metálicos\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/MetalMicroelectrodes_IS.pdf\" target=\"_self\"\u003eUso de microelectrodos metálicos recubiertos con parileno\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003ch2\u003ePreguntas frecuentes\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Qué longitud necesito?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eLa longitud total de cualquier sistema de electrodos se determina principalmente por la profundidad del tejido que se desea registrar o estimular y el sistema de microposicionamiento que se emplea. Las microsondas de tungsteno vienen en longitudes de 76 mm o 125 mm (no se ve 125 um en el sitio web de WPI) o se pueden pedir a medida en cualquier longitud menor a 5 pulgadas. El platino\/iridio típicamente viene en longitudes de dos pulgadas y el acero inoxidable en longitudes de 51 mm, pero cualquiera de los dos también puede especificarse en longitudes más cortas o en longitudes mayores usando acero inoxidable y tubos de poliamida. Debido al alto costo del iridio puro, siempre se monta en tubos de acero inoxidable y poliamida y típicamente mide 50 mm de largo.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Cuál es el grosor del aislamiento?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eTodos los electrodos, excepto el microelectrodo de tungsteno perfil Extra Fino de 3 pulgadas, que tiene un recubrimiento de 1 micrón de aislamiento de Parylene-C, tienen 3 micrones de Parylene-C. Se ha demostrado que este grosor funciona mejor para casi todos los perfiles de punta de electrodo que ofrecemos. Seleccionamos 3 micrones para proporcionar un perfil de punta suficientemente pequeño para acercarse a los elementos neuronales, facilitar la inserción del electrodo y minimizar la atenuación en electrodos de mayor impedancia. La atenuación de la señal puede ocurrir como resultado de un cortocircuito capacitivo al grabar con microelectrodos de mayor impedancia en estructuras profundas, por lo que puede ser necesario un aislamiento adicional en forma de los microelectrodos KT y de poliimida de WPI. El perfil Extra Fino (por ejemplo, TM31C10) para los electrodos de tungsteno de 3 pulgadas ofrece una punta de microelectrodo extremadamente fina, excelente para grabar en estructuras celulares pequeñas y densamente agrupadas.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Qué impedancia o exposición de punta necesito?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eDebido a nuestro proceso único de fabricación y las propiedades especiales del Parylene-C, podemos exponer cualquier microelectrodo con precisión y reproducibilidad microscópica. Cada microelectrodo se expone individualmente bajo un microscopio de alta potencia, se inspecciona y se caracteriza eléctricamente. Nuestros microelectrodos tienen un valor de impedancia más bajo para la misma exposición de la punta que otros electrodos disponibles comercialmente. Por lo tanto, se recomienda que quienes no hayan usado nuestros electrodos antes especifiquen un rango de impedancia para seleccionar el mejor valor de impedancia para su aplicación. Además, dado que hemos estado suministrando microelectrodos a investigadores durante más de 30 años, podemos ofrecer asesoramiento experto para seleccionar el mejor diseño de electrodo para su paradigma experimental. Por favor, contáctenos y proporcione información sobre los requisitos de su investigador. No hay cargo adicional por especificar un rango de valores de impedancia para cualquier caja de microelectrodos.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Qué perfil de punta es el mejor para mi aplicación?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eOfrecemos una variedad de alternativas de punta para aquellos que prefieren un perfil de electrodo especializado para su investigación. La selección de la punta puede proporcionar cambios sutiles pero importantes en el rendimiento del electrodo, como se describe a continuación. Se recomienda que los usuarios primerizos consideren experimentar con diferentes perfiles de punta para determinar cuál funciona mejor para sus protocolos de registro o estimulación. A-Estándar Nuestro perfil de punta estándar presenta un punto afilado pero robusto que ofrece un rendimiento versátil y un equilibrio efectivo entre penetración y durabilidad. El perfil de punta más utilizado, recomendamos nuestra punta estándar para la mayoría de las aplicaciones de registro neural, aunque también es eficaz para la mayoría de los protocolos de estimulación. Empleamos un método de exposición en arco que proporciona un rendimiento preciso y consistente, así como una amplia gama de impedancias disponibles. Aunque este método resulta en una pequeña variabilidad en la impedancia de un electrodo a otro, la mayoría de los investigadores lo encuentran muy aceptable para su aplicación. Para quienes necesitan una exposición de punta más exacta, ofrecemos un servicio de exposición láser por un pequeño costo adicional. Por favor contáctenos si considera que este servicio es adecuado para usted. B-Despuntado Nuestros electrodos despuntados están diseñados para tener una punta más redondeada, con forma de bala. Para muchas aplicaciones, la punta despuntada puede ofrecer un rendimiento superior en estimulación, ya que su perfil más corto puede hacer que el electrodo actúe más como una fuente puntual y proporcione un mejor aislamiento. Muchos investigadores consideran que este perfil ofrece mayor selectividad que los perfiles convencionales de punta más afilada y es más apropiado para protocolos de estimulación de mayor intensidad. Algunos investigadores también han reportado observaciones de que el uso de puntas despuntadas conduce a menos ocurrencias de células perforadas. F-Extra fina Nuestro perfil de punta extra fina presenta un afilado significativamente más pronunciado, así como una capa de aislamiento más delgada. Este tipo de electrodo se usa comúnmente para preparaciones superficiales donde es necesario registrar poblaciones celulares pequeñas y densamente agrupadas, como las capas estriadas de las cortezas visual y auditiva. Debido a la naturaleza muy delicada de estas puntas, solo están disponibles en electrodos de tungsteno, con una longitud de 3 pulgadas (76 mm) y diámetros de eje de 0.003\" y 0.005\" (75 y 125 micrones). Para penetraciones mayores a 4 mm en las que la impedancia de la punta es mayor a 1.5 MΩ, recomendamos especificar una capa adicional de tubo de poliamida para reducir el desvío capacitivo y aumentar la rigidez del electrodo. H-Tratado con calor Nuestros electrodos tratados con calor están destinados a aquellos investigadores que deben penetrar sus sondas a través de membranas resistentes, como la duramadre de mamíferos grandes. Al aplicar una fuente de calor cerca de la punta del electrodo bajo un microscopio, tenemos la capacidad de proporcionar un electrodo con una punta de afilado más gradual que nuestro perfil estándar, además de endurecer el aislamiento de polímero cerca de la punta. Estas modificaciones permiten que el electrodo se empuje más fácilmente a través de membranas resistentes y con menor riesgo de daño en la punta y el aislamiento.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Problemas para leer la impedancia de sus microelectrodos metálicos?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003col\u003e\r\n\u003cli\u003eRevise su medidor de impedancia, tal vez esté midiendo los valores de impedancia a una frecuencia diferente a 1 kilohercio.\u003c\/li\u003e\r\n\u003cli\u003eVerifique si su medidor de impedancia no tiene un circuito de muestra y retención, en cuyo caso la impedancia se mide inmediatamente al presionar el botón de prueba y la impedancia no tiene oportunidad de estabilizarse.\u003c\/li\u003e\r\n\u003cli\u003eNormalmente la impedancia disminuirá después de unos minutos de que el electrodo esté en la solución salina.\u003c\/li\u003e\r\n\u003cli\u003eA veces los electrodos pueden oxidarse aumentando la impedancia, en cuyo caso recomendamos aplicar entre -3 y -4.5 voltios a través del electrodo en solución salina para limpiar y desoxidar el electrodo.\u003c\/li\u003e\r\n\u003c\/ol\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Qué configuración de electrodo necesito?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eActualmente ofrecemos tres configuraciones diferentes de electrodos, aunque en el pasado hemos fabricado muchos diseños personalizados para clientes. Al observar cómo son nuestros números de parte para nuestras sondas, como se ve en la sección de Productos, notará que tienen un número de parte como WE30031.0A5. La parte 00 del número de parte especifica la configuración del microelectrodo. Electrodos monopolares - 00 implica que no hay montaje especial, con la sonda afilada aislada con Parylene-C, teniendo la longitud, ancho, perfil de punta e impedancia según lo especificado en las tablas para ordenar sus electrodos. Electrodos con tubo de poliamida - PT que han sido montados en tubo de poliamida para aumentar la rigidez y proporcionar un grosor adicional de aislamiento. Este montaje se recomienda típicamente cuando electrodos de impedancia bastante alta deben penetrar capas más profundas del cerebro o médula espinal. ST especifica nuestros electrodos bipolares o estereotrodes. Estos electrodos, cuando se ordenan con impedancias menores a 0.5 megaohmios, son excelentes para localizar campos de corriente de estimulación. Estereotrodes de impedancia más alta son excelentes para mejorar el aislamiento de elementos neuronales individuales mediante la grabación simultánea de múltiples unidades en dos microelectrodos muy cercanos. La separación de las puntas suele ser igual al diámetro del eje de uno de los electrodos usados para fabricar el estereotrodo. Se dispone de diferentes separaciones de punta bajo pedido.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Qué tipo de conectores se usan con nuestros electrodos?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eLos conectores de pines 5482, 5483 están unidos al extremo distal de nuestros electrodos. Puede comprar estos conectores así como el conector hembra, M202, haciendo clic aquí y yendo a nuestra página de accesorios. Muchos usuarios prefieren usar nuestros electrodos sin ningún conector, lo cual está bien. Simplemente retiraremos los conectores por usted si lo solicita. No hay descuento por esto ya que los conectores se colocan al inicio de nuestro proceso de fabricación.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Cuáles son las exposiciones de punta para diferentes valores de impedancia del electrodo?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eLas exposiciones de punta para perfiles de punta \"H\" con afilado por calor tienen aproximadamente un 15 a 20 por ciento MÁS exposición. Las exposiciones de punta para perfiles de punta \"B\" romos tienen aproximadamente un 15 a 20 por ciento MENOS exposición. Las exposiciones de punta para perfiles de punta \"F\" extra finos tienen aproximadamente un 10 a 15 por ciento MÁS exposición.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003e¿Problemas para leer la impedancia de sus microelectrodos metálicos?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003col\u003e\r\n\u003cli\u003eRevise su medidor de impedancia, tal vez esté midiendo los valores de impedancia a una frecuencia diferente a 1 kilohercio.\u003c\/li\u003e\r\n\u003cli\u003eVerifique si su medidor de impedancia no tiene un circuito de muestra y retención, en cuyo caso la impedancia se mide inmediatamente al presionar el botón de prueba y la impedancia no tiene oportunidad de estabilizarse.\u003c\/li\u003e\r\n\u003cli\u003eNormalmente la impedancia disminuirá después de unos minutos de que el electrodo esté en la solución salina.\u003c\/li\u003e\r\n\u003cli\u003eA veces los electrodos pueden oxidarse aumentando la impedancia, en cuyo caso recomendamos aplicar entre -3 y -4.5 voltios a través del electrodo en solución salina para limpiar y desoxidar el electrodo.\u003c\/li\u003e\r\n\u003c\/ol\u003e\r\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266221019226,"sku":"PTM23B05","price":420.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/monopolar-electrodes-wpi_3_1_1_6_48cf5b8d-6901-4602-8edc-f50017cfc7d2.jpg?v=1766399163"},{"product_id":"ptm3cc02ins-concentric-bipolar-microelectrode-76-mm-0013-inch","title":"Microelectrodo Bipolar Concéntrico, 76 mm, 0.013 pulgadas","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePlatino Iridio NS fino (3\", 76mm)\u003c\/li\u003e\n\u003cli\u003eImpedancia 200K\u003c\/li\u003e\n\u003cli\u003ePunta de 2-3μm\u003c\/li\u003e\n\u003cli\u003ePaquete de 5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"product-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003eArtículo\u003c\/td\u003e\n\u003ctd\u003eLongitud\u003c\/td\u003e\n\u003ctd\u003eEspesor de\u003cbr\u003eaislamiento\u003c\/td\u003e\n\u003ctd\u003eDiámetro del\u003cbr\u003eeje\u003c\/td\u003e\n\u003ctd\u003eDiámetro de la\u003cbr\u003epunta\u003c\/td\u003e\n\u003ctd\u003eUso típico\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePTM3CC02INS\u003c\/td\u003e\n\u003ctd\u003e76mm \u003c\/td\u003e\n\u003ctd\u003e3µm\u003c\/td\u003e\n\u003ctd\u003e0.400 mm \u003c\/td\u003e\n\u003ctd\u003e2-3µ\u003c\/td\u003e\n\u003ctd\u003eConcéntrico\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNúcleo metálico: \u003c\/strong\u003ePt\/Ir NS fino\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpedancia: \u003c\/strong\u003e200K\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiámetro exterior de la sonda (total): \u003c\/strong\u003eAislado (325μm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiámetro del núcleo: \u003c\/strong\u003e50.8μm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensión Y: \u003c\/strong\u003e0.25mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensión X con poliamida: \u003c\/strong\u003e126μm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCantidad: \u003c\/strong\u003ePaquete de 5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/MetalMicroelectrodes_IS.pdf\" target=\"_self\"\u003eUso de microelectrodos metálicos recubiertos con Parylene\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003ePreguntas frecuentes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Qué longitud necesito?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLa longitud total de cualquier sistema de electrodos se determina principalmente por la profundidad del tejido que se desea registrar o estimular y el sistema de microavance que se emplea. Las microsondas de tungsteno vienen en longitudes de 76 mm o 125 mm (no se ve 125 um en el sitio web de WPI) o pueden pedirse a medida en cualquier longitud menor a 5 pulgadas. El platino\/iridio suele venir en longitudes de dos pulgadas y el acero inoxidable en longitudes de 51 mm, pero ambos también pueden especificarse en longitudes más cortas o más largas usando acero inoxidable y tubos de poliamida. Debido al alto costo del iridio puro, siempre se monta en acero inoxidable y tubos de poliamida y típicamente mide 50 mm de largo.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Cuál es el espesor del aislamiento?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTodos los electrodos, excepto la microsonda de tungsteno Extra Fina-F de 3 pulgadas, que tiene un recubrimiento de 1 micrón de aislamiento de Parylene-C, tienen 3 micrones de Parylene-C. Se ha demostrado que este espesor funciona mejor para casi todos los perfiles de punta de electrodos que ofrecemos. Seleccionamos 3 micrones para proporcionar un perfil de punta suficientemente pequeño para acercarse a los elementos neuronales, facilitar la inserción del electrodo y minimizar la atenuación en electrodos de alta impedancia. La atenuación de la señal puede ocurrir debido a un cortocircuito capacitivo al registrar con microsondas de alta impedancia en estructuras profundas, por lo que puede ser necesario un aislamiento adicional en forma de microsondas KT de WPI con poliamida. El perfil Extra Fino (ej. TM31C10) para los electrodos de tungsteno de 3 pulgadas ofrece una punta de microsonda extremadamente fina, excelente para registrar en estructuras celulares pequeñas y densamente agrupadas.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Qué impedancia o exposición de punta necesito?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eGracias a nuestro proceso de fabricación único y las propiedades especiales del Parylene-C, podemos exponer cualquier microsonda con precisión microscópica y reproducibilidad. Cada microsonda se expone individualmente bajo un microscopio de alta potencia, se inspecciona y se caracteriza eléctricamente. Nuestras microsondas tienen un valor de impedancia más bajo para la misma exposición de punta que otros electrodos disponibles comercialmente. Por lo tanto, se recomienda que quienes no hayan usado nuestros electrodos antes especifiquen un rango de impedancia para seleccionar el mejor valor para su aplicación. Además, dado que hemos suministrado microsondas a investigadores por más de 30 años, podemos ofrecer asesoría experta para seleccionar el mejor diseño de electrodo para su paradigma experimental. Por favor contáctenos y proporcione información sobre los requisitos de su investigación. No hay cargo adicional por especificar un rango de valores de impedancia para cualquier caja de microsondas.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Qué perfil de punta es mejor para mi aplicación?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOfrecemos una variedad de alternativas de punta para quienes prefieren un perfil especializado para su investigación. La selección de la punta puede proporcionar cambios sutiles pero importantes en el rendimiento del electrodo, como se describe a continuación. Se recomienda que los usuarios primerizos experimenten con diferentes perfiles para determinar cuál funciona mejor para sus protocolos de registro o estimulación. A-Estándar Nuestro perfil estándar presenta una punta afilada pero robusta que ofrece un rendimiento versátil y un equilibrio efectivo entre penetración y durabilidad. Es el perfil de punta más utilizado; recomendamos nuestro perfil estándar para la mayoría de aplicaciones de registro neural, aunque también es efectivo para la mayoría de protocolos de estimulación. Empleamos un método de exposición por arco que proporciona un rendimiento preciso y consistente, así como un rango muy amplio de impedancias disponibles. Aunque este método genera una pequeña variabilidad en la impedancia entre electrodos, la mayoría de los investigadores lo encuentran muy aceptable para su aplicación. Para quienes necesitan una exposición de punta más exacta, ofrecemos un servicio de exposición láser por un pequeño costo adicional. Por favor contáctenos si cree que este servicio es adecuado para usted. B-Despuntado Nuestros electrodos despuntados están diseñados con una punta más redondeada, en forma de bala. Para muchas aplicaciones, la punta despuntada puede ofrecer un mejor rendimiento en estimulación, ya que su perfil más corto puede hacer que el electrodo actúe más como una fuente puntual y proporcione mejor aislamiento. Muchos investigadores consideran que este perfil ofrece mayor selectividad que los perfiles convencionales más afilados y es más apropiado para protocolos de estimulación de mayor intensidad. Algunos investigadores también han observado que el uso de puntas despuntadas reduce la ocurrencia de células perforadas. F-Extra fino Nuestro perfil extra fino presenta un afilado significativamente mayor y una capa de aislamiento más delgada. Este tipo de electrodo se usa comúnmente en preparaciones superficiales donde es necesario registrar poblaciones celulares pequeñas y densamente agrupadas, como las capas estriadas de las cortezas visual y auditiva. Debido a la naturaleza muy delicada de estas puntas, solo están disponibles en electrodos de tungsteno, en longitud de 3 pulgadas (76mm) y diámetros de eje de 0.003\" y 0.005\" (75 y 125 micrones). Para penetraciones mayores a 4 mm en las que la impedancia de la punta es mayor a 1.5 MΩ, recomendamos especificar una capa adicional de tubo de poliamida para reducir el cortocircuito capacitivo y aumentar la rigidez del electrodo. H-Tratado térmicamente Nuestros electrodos tratados térmicamente están destinados a investigadores que deben penetrar sus sondas a través de membranas resistentes, como la duramadre de mamíferos grandes. Aplicando una fuente de calor cerca de la punta del electrodo bajo un microscopio, podemos proporcionar un electrodo con una punta de afilado más gradual que nuestro perfil estándar, además de endurecer el aislamiento de polímero cerca de la punta. Estas modificaciones permiten que el electrodo atraviese membranas resistentes con mayor facilidad y menor riesgo de daño en la punta y el aislamiento.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Problemas para leer la impedancia de sus microelectrodos metálicos?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003col\u003e\n\u003cli\u003eVerifique su medidor de impedancia, tal vez esté midiendo a una frecuencia diferente a 1 kilohertz.\u003c\/li\u003e\n\u003cli\u003eCompruebe si su medidor de impedancia no tiene un circuito de muestreo y retención, en cuyo caso la impedancia se mide inmediatamente al presionar el botón de prueba y no tiene tiempo para estabilizarse.\u003c\/li\u003e\n\u003cli\u003eGeneralmente la impedancia disminuye después de unos minutos de que el electrodo está en solución salina.\u003c\/li\u003e\n\u003cli\u003eA veces los electrodos pueden oxidarse aumentando la impedancia; en ese caso recomendamos aplicar entre -3 y -4.5 voltios a través del electrodo en solución salina para limpiarlo y desoxidar el electrodo.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Qué configuración de electrodo necesito?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eActualmente ofrecemos tres configuraciones diferentes de electrodos, aunque en el pasado hemos fabricado muchos diseños personalizados para clientes. Al observar nuestros números de parte para las sondas, como se ve en la sección de Productos, notará que tienen un número como WE30031.0A5. La parte \"00\" del número especifica la configuración de la microsonda. Electrodos monopolares - 00 Indica que no hay montaje especial, con la sonda afilada aislada con Parylene-C, con la longitud, ancho, perfil de punta e impedancia especificados en las tablas para ordenar sus electrodos. Tubo de poliamida - PT Electrodos montados en tubo de poliamida para aumentar la rigidez y proporcionar mayor espesor de aislamiento. Este montaje se recomienda típicamente cuando electrodos de impedancia bastante alta deben penetrar capas más profundas del cerebro o médula espinal. ST Especifica nuestros electrodos bipolares o estereotrodes. Estos electrodos, cuando se piden con impedancias menores a 0.5 megaohmios, son excelentes para localizar campos de corriente de estimulación. Los estereotrodes de mayor impedancia son excelentes para mejorar el aislamiento de elementos neuronales individuales mediante el registro simultáneo de múltiples unidades en dos microelectrodos cercanos. La separación de las puntas suele ser igual al diámetro del eje de uno de los electrodos usados para fabricar el estereotrodo. Se dispone de diferentes separaciones de punta bajo pedido.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Qué tipo de conectores se usan con nuestros electrodos?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLos conectores de pines 5482, 5483 están fijados al extremo distal de nuestros electrodos. Puede comprar estos conectores así como el conector hembra, M202, haciendo clic aquí y visitando nuestra página de accesorios. Muchos usuarios prefieren usar nuestros electrodos sin ningún conector, lo cual está bien. Simplemente retiraremos los conectores si lo solicita. No hay descuento por esto ya que los conectores se fijan al inicio de nuestro proceso de fabricación.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Cuáles son las exposiciones de punta para diferentes valores de impedancia del electrodo?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLas exposiciones de punta para perfiles de punta con afilado térmico \"H\" tienen aproximadamente un 15 a 20 por ciento MÁS de exposición. Las exposiciones de punta para perfiles despuntados \"B\" tienen aproximadamente un 15 a 20 por ciento MENOS de exposición. Las exposiciones de punta para perfiles extra finos \"F\" tienen aproximadamente un 10 a 15 por ciento MÁS de exposición.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e¿Problemas para leer la impedancia de sus microelectrodos metálicos?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003col\u003e\n\u003cli\u003eVerifique su medidor de impedancia, tal vez esté midiendo a una frecuencia diferente a 1 kilohertz.\u003c\/li\u003e\n\u003cli\u003eCompruebe si su medidor de impedancia no tiene un circuito de muestreo y retención, en cuyo caso la impedancia se mide inmediatamente al presionar el botón de prueba y no tiene tiempo para estabilizarse.\u003c\/li\u003e\n\u003cli\u003eGeneralmente la impedancia disminuye después de unos minutos de que el electrodo está en solución salina.\u003c\/li\u003e\n\u003cli\u003eA veces los electrodos pueden oxidarse aumentando la impedancia; en ese caso recomendamos aplicar entre -3 y -4.5 voltios a través del electrodo en solución salina para limpiarlo y desoxidar el electrodo.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266221051994,"sku":"PTM3CC02INS","price":775.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/con-bipolar-wpi_1_d9180f08-2b50-4471-9a9b-e2254cfb4be0.jpg?v=1766399171"},{"product_id":"r-8-8-wpi01-ring-light-guide-for-pzm-and-pzmiii-series-microscopes","title":"Guía de Luz Anular para Microscopios de las Series PZM y PZMIII","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePara usar con microscopios de las series PZM y PZMIII\u003c\/li\u003e\n\u003cli\u003ePermite una iluminación sin sombras\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266222624858,"sku":"R-8-8-WPI01","price":579.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/r-8-8-wpi01_eef40fc7-e8bd-4fd0-93a5-609d20e5d000.jpg?v=1766399234"},{"product_id":"var-3317-replacement-rems-hts-electrode","title":"Electrodo REMS HTS de Repuesto","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eElectrodos de reemplazo para usar con el sistema de medición robótica TEER REMS\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOpciones\u003c\/h2\u003e\r\n\u003ctable\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eCódigo de pedido\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eDescripción\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cstrong\u003eREMS-24\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003eElectrodo REMS HTS de reemplazo para placa Millipore de 24 pocillos\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003e\u003cstrong\u003eREMS-24M\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003eElectrodo REMS HTS de reemplazo para placas de inserto de cultivo celular Millicell-24\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cstrong\u003eREMS-96\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003eElectrodo REMS HTS de reemplazo para placa Millipore de 96 pocillos\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003e\u003cstrong\u003eREMS-96C\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003eElectrodo REMS HTS de reemplazo para placa Corning de 96 pocillos\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/Replacement_REMS_50742840e4bf8_6f47c0fb-9e5d-4091-bb1f-01ae4ea1d7a9.jpg?v=1765947538\" alt=\"REMS-24\" width=\"597\" height=\"304\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eElectrodo de reemplazo para usar con placas de 24 pocillos.\u003c\/p\u003e\r\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/Replacement_REMS_4a859eee679b4_8cc3591f-7cce-49d0-8bb8-076caef4fcf6.jpg?v=1765947544\" alt=\"REMS-96\" width=\"219\" height=\"123\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eElectrodo de reemplazo y electrodo ficticio para usar con placas de 96 pocillos.\u003c\/p\u003e\r\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/REMS-24M_med_b1df6dc9-1e8c-416e-b5b3-627462c5aa29.jpg?v=1765947549\" alt=\"Electrodo de reemplazo REMS-24M\" width=\"500\" height=\"333\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eElectrodo de reemplazo y electrodo ficticio para usar con placas de inserto de cultivo celular Millicell-24.\u003c\/p\u003e\r\n\u003ch2\u003ePlacas de pocillos para usar con la medición robótica TEER REMS\u003c\/h2\u003e\r\n\u003cp\u003eLas siguientes placas pueden usarse con el sistema REMS:\u003c\/p\u003e\r\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd colspan=\"2\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eREMS-24\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eREMS-24M\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eREMS-96\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eREMS-96\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eREMS-96C\u003c\/strong\u003e \u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003eCorning HTS Transwell\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003eBD Falcon HTS MultiWell\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003eMillicell-24\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003eMillipore HTS96 Multiwell\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003eBD Falcon\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003eCorning HTS Transwell\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd style=\"text-align: center;\"\u003e3378\u003cbr\u003e3379\u003cbr\u003e3396\u003cbr\u003e3397\u003cbr\u003e3398\u003cbr\u003e3399\u003c\/td\u003e\r\n\u003ctd style=\"background-color: #e4e4e4; text-align: center;\"\u003e351180\u003cbr\u003e351181\u003cbr\u003e351182\u003cbr\u003e351183\u003cbr\u003e351184\u003cbr\u003e351185\u003cbr\u003e354803\u003cbr\u003e354804\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\"\u003ePSHT010R1\u003cbr\u003ePSST010R1\u003cbr\u003ePSMT010R1\u003cbr\u003ePSET010R1\u003cbr\u003ePSRP010R1\u003c\/td\u003e\r\n\u003ctd style=\"background-color: #e4e4e4; text-align: center;\"\u003ePSHT004R1\u003cbr\u003ePSRP004R1\u003cbr\u003ePSHT010R5\u003cbr\u003ePSRP004R5\u003cbr\u003ePSHT004S5\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\"\u003e351130\u003cbr\u003e351131\u003cbr\u003e351161\u003cbr\u003e351162\u003cbr\u003e351163\u003cbr\u003e351164\u003cbr\u003e353938\u003c\/td\u003e\r\n\u003ctd style=\"background-color: #e4e4e4; text-align: center;\"\u003e3380\u003cbr\u003e3392\u003cbr\u003e3381\u003cbr\u003e3391\u003cbr\u003e3385\u003cbr\u003e3386\u003cbr\u003e3387\u003cbr\u003e3388\u003cbr\u003e3374\u003cbr\u003e3384\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003ch2\u003ePlacas de muestra\u003c\/h2\u003e\r\n\u003ctable style=\"width: 100%; height: 668px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"height: 145px;\"\u003e\r\n\u003ctd style=\"width: 28.8538%; height: 145px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/3378.jpg\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/3378_thm_5a90c850-2912-425c-b840-dc53866cfee1.jpg?v=1765947555\" alt=\"\" width=\"100\" height=\"70\"\u003e\u003cbr\u003eHaga clic para ampliar.\u003c\/a\u003e\u003c\/td\u003e\r\n\u003ctd style=\"width: 70.224%; height: 145px;\"\u003e\r\n\u003cp\u003eEsta es una placa Corning #3378 de 24 pocillos que puede usarse con el \u003cstrong\u003eREMS-24\u003c\/strong\u003e o el \u003cstrong\u003eSTX100C\u003c\/strong\u003e.\u003c\/p\u003e\r\n\u003cp\u003eLa placa BD Falcon de 24 pocillos es prácticamente idéntica a esta. Para usar con \u003cstrong\u003eREMS-24\u003c\/strong\u003e o \u003cstrong\u003eSTX100F\u003c\/strong\u003e.\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 145px;\"\u003e\r\n\u003ctd style=\"width: 28.8538%; height: 145px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/BDFalcon96.jpg\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/BDFalcon96_thm_37e5a34e-6ed9-47b1-8eed-fcd0888e0d35.jpg?v=1765947560\" alt=\"\" width=\"100\" height=\"68\"\u003e\u003cbr\u003eHaga clic para ampliar.\u003c\/a\u003e\u003c\/td\u003e\r\n\u003ctd style=\"width: 70.224%; height: 145px;\"\u003eEsta es una placa BD Falcon de 96 pocillos que puede usarse con el \u003cstrong\u003eREMS-96\u003c\/strong\u003e.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 145px;\"\u003e\r\n\u003ctd style=\"width: 28.8538%; height: 145px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/MPcaco2.jpg\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/MPcaco2_thm_044fb496-9cf4-4c31-8675-26b80d077712.jpg?v=1765947566\" alt=\"\" width=\"100\" height=\"67\"\u003e\u003cbr\u003eHaga clic para ampliar.\u003c\/a\u003e\u003c\/td\u003e\r\n\u003ctd style=\"width: 70.224%; height: 145px;\"\u003eEsta es una placa Millipore Multiscreen CaCo2 que puede usarse con el \u003cstrong\u003eREMS-96\u003c\/strong\u003e o el \u003cstrong\u003eSTX100M\u003c\/strong\u003e.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 145px;\"\u003e\r\n\u003ctd style=\"width: 28.8538%; height: 145px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/3391.jpg\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/3391_thm_52368e72-fc45-4e31-933d-4b59e2dafc2f.jpg?v=1765947571\" alt=\"\" width=\"100\" height=\"71\"\u003e\u003cbr\u003eHaga clic para ampliar.\u003c\/a\u003e\u003c\/td\u003e\r\n\u003ctd style=\"width: 70.224%; height: 145px;\"\u003eEsta es una placa Corning 3391 HTS Traswell 96 que puede usarse con el \u003cstrong\u003eREMS-96C\u003c\/strong\u003e o el \u003cstrong\u003eSTX100C96\u003c\/strong\u003e. \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"height: 88px;\"\u003e\r\n\u003ctd style=\"width: 28.8538%; height: 88px;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/millicell24-plate_thm_8b2e2e8f-2ad3-4f2a-86f4-1be75c4bec86.jpg?v=1765947577\" alt=\"placa de pocillos millicell-24\" width=\"110\" height=\"66\"\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/millicell24-plate.jpg\"\u003eHaga clic para ampliar.\u003c\/a\u003e\n\u003c\/td\u003e\r\n\u003ctd style=\"width: 70.224%; height: 88px;\"\u003eEsta es una placa de inserto de cultivo celular Millicell-24 que puede usarse con el REMS-24M\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp style=\"margin-left: 24.0pt; text-indent: -24.0pt;\"\u003eSharma, A., Lee, J., Fonseca, A. G., Moshensky, A., Kothari, T., Sayed, I. M., Ibeawuchi, S.-R., Pranadinata, R. F., Ear, J., Sahoo, D., Crotty-Alexander, L. E., Ghosh, P., \u0026amp; Das, S. (2021). Los cigarrillos electrónicos comprometen la barrera intestinal y desencadenan inflamación. \u003cem\u003eISCIENCE\u003c\/em\u003e, \u003cem\u003e24\u003c\/em\u003e, 102035. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.isci.2021.102035\"\u003ehttps:\/\/doi.org\/10.1016\/j.isci.2021.102035\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24.0pt; text-indent: -24.0pt;\"\u003eSayed, I. M., Tindle, C., Fonseca, A. G., Ghosh, P., \u0026amp; Das, S. (2021). Ensayos funcionales con monocapas de enteroides derivados de pacientes humanos para evaluar la barrera intestinal humana. \u003cem\u003eSTAR Protocols\u003c\/em\u003e, \u003cem\u003e2\u003c\/em\u003e(3), 100680. \u003ca href=\"https:\/\/doi.org\/10.1016\/J.XPRO.2021.100680\"\u003ehttps:\/\/doi.org\/10.1016\/J.XPRO.2021.100680\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Milipore 24","offer_id":42266225180762,"sku":"REMS-24","price":7000.0,"currency_code":"USD","in_stock":true},{"title":"Millicell 24","offer_id":42266225213530,"sku":"REMS-24M","price":7000.0,"currency_code":"USD","in_stock":true},{"title":"Millipore 96","offer_id":42266225246298,"sku":"REMS-96","price":7000.0,"currency_code":"USD","in_stock":true},{"title":"Corning 96","offer_id":42266225279066,"sku":"REMS-96C","price":7000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/replacement_rems_50742840e4bf8_59be3413-749e-4399-b42c-14bb9fec0ca7.jpg?v=1766399289"},{"product_id":"stx2-chopstick-electrode-set-for-evom2-4mm","title":"Electrodos STX2 TEER tipo Palillos, Equivalente Mersstx01","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eEsterilización\u003c\/h2\u003e\r\n\u003cp\u003eSTX2 puede ser esterilizado con EtO, alcohol o un bactericida\u003c\/p\u003e\r\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eElectrodos dobles de ancho fijo de 4mm\u003c\/li\u003e\r\n\u003cli\u003e1mm de grosor\u003c\/li\u003e\r\n\u003cli\u003eUso en pocillos de cultivo celular\u003c\/li\u003e\r\n\u003cli\u003eCompatible con EVOM™, EVOM2, ERS, ERS2 (Millipore)\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ctable\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/YK1mtLovckQ\" width=\"600\" height=\"450\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/fW1x9vKK18Q?rel=0\" width=\"600\" height=\"450\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/o2ykItULEQg?rel=0\" width=\"600\" height=\"450\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/td\u003e\r\n\u003ctd\u003e \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/STX2-DC.pdf\"\u003eDeclaración de conformidad\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/STX2_IM.pdf\"\u003eManual de instrucciones STX2\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:references --\u003e\n\u003c!------------------------------ start embed code -------------------------------------\u003e\r\n\u003cobject id=\"wobj-841-STX2-q\" type=\"text\/html\" data=\"https:\/\/www.bioz.com\/v_widget_6_0\/841\/STX2\/\" style=\"width:100%; height: 193px\"\u003e\u003c\/object\u003e \u003cdiv id=\"bioz-w-pb-841-STX2-q-div\" style=\"width: 100%\"\u003e\n\u003ca id=\"bioz-w-pb-841-STX2-q\" style=\"font-size: 12px;text-decoration:none;color:#00AFE9\" href=\"https:\/\/www.bioz.com\/\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.bioz.com\/assets\/favicon.png\" style=\"width:11px;height:11px;vertical-align: baseline;padding-bottom:0px;margin-left:0px;margin-bottom:0px;float:none\" alt=\"impulsado por bioz\"\u003e Impulsado por Bioz\u003c\/a\u003e \u003ca style=\"font-size: 12px;text-decoration:none;float: right;color:transparent\" href=\"https:\/\/www.bioz.com\/result\/STX2\/product\/World%20Precision%20Instruments\/?cn=STX2\" target=\"_blank\"\u003e Ver más detalles en Bioz\u003c\/a\u003e\n\u003c\/div\u003e\r\n\u003c!------------------------------ end embed code ---------------------------------------\u003e\r\n\u003c!-- \u003cp\u003e\u003cstrong\u003eL.Ye, T.A. Martin, C. Parry, G.M. Harrison, R.E. Mansel, W.G. Jiang\u003c\/strong\u003e \"Biphasic effects of 17-Î²-estradiol on expression of occuludin and transendothelial resistance and paracellular permeability inhuman vascular endothelial cells\" \u003cspan style=\"font-style: italic;\"\u003eJ of Cellular Physiology\u003c\/span\u003e 196. 2003: 362-369\u003c\/p\u003e --\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266235764826,"sku":"STX2","price":575.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/stx2_8a8ff1cc-35d3-4846-95d3-9d2cbc834d01.jpg?v=1766399531"},{"product_id":"sys-705-ultra-quiet-intracellular-amplifier","title":"Amplificador Intracelular Ultra Silencioso","description":"\u003c!-- section:details --\u003e\n\u003cp\u003e\u003ca href=\"\/es\/blog\/post\/wpi-s-low-noise-amplifiers-outperform-cheap-imitations\"\u003eVea lo que necesita saber antes de comprar un amplificador\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEscudo de guardia conducido\u003c\/li\u003e\n\u003cli\u003ePuerto de prueba\u003c\/li\u003e\n\u003cli\u003ePuerto de tierra\u003c\/li\u003e\n\u003cli\u003ePortátil\u003c\/li\u003e\n\u003cli\u003eCabezal remoto\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBeneficios\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRentable\u003c\/li\u003e\n\u003cli\u003eAlimentado por batería\u003c\/li\u003e\n\u003cli\u003eCompensación de capacitancia\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMedir potenciales de acción intracelulares\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectro 705\u003c\/strong\u003e incluye 1 unidad de cada \u003ca href=\"\/es\/var-3786-microelectrode-holder-meh1sf\"\u003eSoporte para microelectrodo\u003c\/a\u003e: MEH1SF10, MEH1SF12, MEH1SF15 y MEH1SF20. Se recomienda el \u003ca href=\"\/es\/var-3316-reference-cells\"\u003eRC1T\u003c\/a\u003e para el electrodo de referencia.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectro 705\u003c\/strong\u003e, un preamplificador electrométrico de bajo ruido, banda ancha y alimentado por batería, está diseñado para la medición de voltaje intracelular. Dos unidades 705 pueden enlazarse para formar un par electrométrico diferencial de alta impedancia. Cada instrumento incluye una sonda activa miniatura chapada en oro a la que se puede conectar un microelectrodo usando el soporte para microelectrodo WPI suministrado.\u003c\/p\u003e\n\u003ch2\u003eCabezal remoto\u003c\/h2\u003e\n\u003cp\u003eFácilmente montada en cualquier manipulador, esta sonda compacta, que contiene la primera etapa de amplificación, incluye un soporte para microelectrodo que se conecta directamente a la entrada de la sonda.\u003c\/p\u003e\n\u003ch2\u003eAlimentación por batería\u003c\/h2\u003e\n\u003cp\u003eCuatro baterías alcalinas de 9V (incluidas) alimentan el \u003cstrong\u003eElectro 705\u003c\/strong\u003e durante aproximadamente 500 horas, proporcionando una fuente de energía limpia y de bajo ruido, haciendo del \u003cstrong\u003eElectro 705\u003c\/strong\u003e el amplificador más silencioso disponible. Las baterías pueden probarse fácilmente con solo presionar un botón.\u003c\/p\u003e\n\u003ch2\u003eCompensación de capacitancia\u003c\/h2\u003e\n\u003cp\u003eCorrige la pérdida de tiempo de subida causada por la capacidad del electrodo. Se puede neutralizar hasta 50 pF de capacidad en paralelo del electrodo.\u003c\/p\u003e\n\u003ch2\u003eEscudo de guardia conducido\u003c\/h2\u003e\n\u003cp\u003eLa capacitancia parásita puede reducirse aún más colocando el escudo de guardia conducido (incluido) sobre el soporte del microelectrodo en el extremo de entrada de la sonda.\u003c\/p\u003e\n\u003ch2\u003eFunciones de prueba\u003c\/h2\u003e\n\u003cp\u003eUn circuito Tickler ofrece una oscilación momentánea que ayuda a lograr la penetración celular. El \u003cstrong\u003eElectro 705\u003c\/strong\u003e proporciona una corriente de prueba de electrodo de 1 nA. La resistencia del electrodo se monitorea en la salida 1X como un voltaje (1 mV\/M). El puerto de prueba de la sonda permite la comodidad de probar el ruido intrínseco y la ganancia del amplificador sin conexiones externas engorrosas. La corriente de fuga del cabezal también puede ajustarse con mínimo esfuerzo. El control de posición de línea base añade o resta hasta 300 mV a la salida del cabezal, permitiendo anular voltajes artefacto como potenciales de unión líquida antes de la grabación.\u003c\/p\u003e\n\u003ch2\u003eSalida diferencial\u003c\/h2\u003e\n\u003cp\u003eDos unidades \u003cstrong\u003eElectro 705\u003c\/strong\u003e pueden conectarse en tándem para crear un sistema opcional de sonda amplificadora diferencial.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/Electro705_IMs.pdf\" target=\"_self\"\u003eManual de instrucciones Electro705\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eImpedancia de entrada\u003c\/td\u003e\r\n\u003ctd\u003e10\u003csup\u003e12\u003c\/sup\u003e Ω, en paralelo con 1pF\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eImpedancia de salida\u003c\/td\u003e\r\n\u003ctd\u003e100 Ω, ambas salidas\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eGanancia\u003c\/td\u003e\r\n\u003ctd\u003eX1: ±0.1%\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eRango de voltaje de entrada\u003c\/td\u003e\r\n\u003ctd\u003e±5 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTiempo de subida\u003c\/td\u003e\r\n\u003ctd\u003e15 µs, 10-90%\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eNivel de ruido\u003c\/td\u003e\r\n\u003ctd\u003e500 μV pico a pico*\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCompensación de capacitancia de entrada\u003c\/td\u003e\r\n\u003ctd\u003e0-50 pF\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eCorriente de fuga de la compuerta\u003c\/td\u003e\r\n\u003ctd\u003e±10 pA, ajustable a cero\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ePrueba de resistencia del electrodo\u003c\/td\u003e\r\n\u003ctd\u003e1 mV\/MΩ\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003ePosicionamiento de CC\u003c\/td\u003e\r\n\u003ctd\u003e±300 mV\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRechazo de modo común\u003c\/td\u003e\r\n\u003ctd\u003e\u0026gt;10\u003csup\u003e4\u003c\/sup\u003e (en modo diferencial)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eAlimentación\u003c\/td\u003e\r\n\u003ctd\u003eCuatro pilas alcalinas de 9 V, incluidas\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDimensiones\u003c\/td\u003e\r\n\u003ctd\u003e8.5 x 3.5 x 2.2 in. (22 x 9 x 6 cm)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003ePeso de envío\u003c\/td\u003e\r\n\u003ctd\u003e5 lb. (2.3 kg)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eWan, E., Kushner, J. S., Zakharov, S., Nui, X.-W., Chudasama, N., Kelly, C., … Marx, S. O. (2013). La reducción de la corriente del canal BK en músculo liso vascular subyace a la vasoconstricción inducida por insuficiencia cardíaca en ratones. \u003ci\u003eFASEB Journal : Official Publication of the Federation of American Societies for Experimental Biology\u003c\/i\u003e, \u003ci\u003e27\u003c\/i\u003e(5), 1859–67. \u003ca href=\"http:\/\/doi.org\/10.1096\/fj.12-223511\"\u003ehttp:\/\/doi.org\/10.1096\/fj.12-223511\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eGokina, N. I., Bonev, A. D., Gokin, A. P., \u0026amp; Goloman, G. (2013). Papel de la señalización de Ca2+ alterada en células endoteliales en la disfunción vascular uteroplacentaria durante el embarazo diabético en ratas. \u003ci\u003eAmerican Journal of Physiology - Heart and Circulatory Physiology\u003c\/i\u003e, \u003ci\u003e304\u003c\/i\u003e(7).\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eThomas, R. C., \u0026amp; Bers, D. M. (2013). Cómo fabricar minielectrodos sensibles al calcio. \u003ci\u003eCold Spring Harbor Protocols\u003c\/i\u003e, \u003ci\u003e2013\u003c\/i\u003e(4), 370–3. \u003ca href=\"http:\/\/doi.org\/10.1101\/pdb.prot072850\"\u003ehttp:\/\/doi.org\/10.1101\/pdb.prot072850\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKinoshita, H., Matsuda, N., Iranami, H., Ogawa, K., Hatakeyama, N., Azma, T., … Yamazaki, M. (2012). El pretratamiento con isoflurano preserva la función del canal K+ sensible al trifosfato de adenosina en la arteria humana expuesta al estrés oxidativo causado por niveles altos de glucosa. \u003ci\u003eAnesthesia \u0026amp; Analgesia\u003c\/i\u003e, \u003ci\u003e115\u003c\/i\u003e(1), 54–61. \u003ca href=\"http:\/\/doi.org\/10.1213\/ANE.0b013e318254270d\"\u003ehttp:\/\/doi.org\/10.1213\/ANE.0b013e318254270d\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eHaba, M., Kinoshita, H., Matsuda, N., Azma, T., Hama-Tomioka, K., Hatakeyama, N., … Hatano, Y. (2009). Efecto beneficioso del propofol sobre la función del canal K+ sensible al trifosfato de adenosina arterial afectada por tromboxano. \u003ci\u003eAnesthesiology\u003c\/i\u003e, \u003ci\u003e111\u003c\/i\u003e(2), 279–286. \u003ca href=\"http:\/\/doi.org\/10.1097\/ALN.0b013e3181a918a0\"\u003ehttp:\/\/doi.org\/10.1097\/ALN.0b013e3181a918a0\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eZheng, J., \u0026amp; Pollack, G. H. (2006). Exclusión de solutos y distribución potencial cerca de superficies hidrofílicas. En \u003ci\u003eWater and the Cell\u003c\/i\u003e (pp. 165–174). Dordrecht: Springer Netherlands. \u003ca href=\"http:\/\/doi.org\/10.1007\/1-4020-4927-7_8\"\u003ehttp:\/\/doi.org\/10.1007\/1-4020-4927-7_8\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003ePeters, O., Back, T., Lindauer, U., Busch, C., Megow, D., Dreier, J., \u0026amp; Dirnagl, U. (1998). Aumento de la formación de especies reactivas de oxígeno tras la oclusión permanente y reversible de la arteria cerebral media en la rata, \u003ci\u003e18\u003c\/i\u003e(2), 196–205. \u003ca href=\"http:\/\/doi.org\/10.1097\/00004647-199802000-00011\"\u003ehttp:\/\/doi.org\/10.1097\/00004647-199802000-00011\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266235797594,"sku":"SYS-705","price":2800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/705-front_5a2fdcee-735a-40d4-b3cb-7445abfd79b3.jpg?v=1766399540"},{"product_id":"sys-773-duo-773-electrometer","title":"Electrómetro Duo 773","description":"\u003c!-- section:details --\u003e\n\u003cp\u003e\u003ca href=\"\/es\/blog\/post\/wpi-s-low-noise-amplifiers-outperform-cheap-imitations\"\u003eVea lo que necesita saber antes de comprar un amplificador\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eBeneficios\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRegistro de canal dual, simple extremo\u003c\/li\u003e\n\u003cli\u003eRegistro diferencial\u003c\/li\u003e\n\u003cli\u003eEl circuito puente anula la caída de voltaje del electrodo\u003c\/li\u003e\n\u003cli\u003eAsignar filtro paso bajo a cualquiera de los canales\u003c\/li\u003e\n\u003cli\u003eEl canal de impedancia muy alta puede usarse con ISE intracelular\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrofisiología intracelular usando micropipetas afiladas\u003c\/li\u003e\n\u003cli\u003eRegistro intracelular en cortes cerebrales\u003c\/li\u003e\n\u003cli\u003e\nRegistro intracelular \u003cem\u003ein vivo\u003c\/em\u003e del cerebro y la médula espinal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ciframe style=\"font-size: 12px;\" src=\"https:\/\/www.youtube.com\/embed\/hJGEkjS3OUk?rel=0\" width=\"560\" height=\"315\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003ePara estudios intracelulares duales o diferenciales, el \u003cstrong\u003eDuo773 \u003c\/strong\u003e tiene controles separados de capacidad negativa y filtrado activo incorporado que permite el equilibrio preciso de constantes de tiempo para mediciones diferenciales sin artefactos. Viene completo con dos cabezales de sonda, sondas de 10\u003csup\u003e15\u003c\/sup\u003eΩ y 10\u003csup\u003e11\u003c\/sup\u003eΩ para monitorear señales de microelectrodos específicos de iones, así como electrodos llenos de KCl.\u003c\/p\u003e\n\u003ch2\u003eCabezal para posicionamiento preciso\u003c\/h2\u003e\n\u003cp\u003eDos sondas activas miniatura chapadas en oro y selladas con epoxi pueden posicionarse directamente en el sitio de medición. Los soportes para microelectrodos que contienen semielectrodos electroquímicos de Ag\/AgCl se conectan directamente a las sondas. La capacitancia parásita puede reducirse colocando el escudo de guardia conducido incluido sobre el soporte del microelectrodo al final de la sonda.\u003c\/p\u003e\n\u003ch2\u003eCompensación de capacidad\u003c\/h2\u003e\n\u003cp\u003eEl canal A puede compensar hasta 10 pF de capacidad de derivación del electrodo y el canal B puede compensar hasta 50 pF.\u003c\/p\u003e\n\u003ch2\u003eCircuito Tickler para penetración\u003c\/h2\u003e\n\u003cp\u003eUn circuito Tickler ayuda en la penetración celular. La frecuencia y amplitud de las oscilaciones pueden variar según las diferencias en el grosor de la membrana o el tamaño celular. La duración del tickle puede controlarse usando el interruptor momentáneo, un pedal o aplicando una señal a la entrada remota del tickler.\u003c\/p\u003e\n\u003ch2\u003eFiltros activos\u003c\/h2\u003e\n\u003cp\u003eLos ajustes de paso bajo en un filtro activo de -40 dB\/década varían el corte de 1 a 30 kHz. Se puede seleccionar la salida de la sonda o del puente para el filtrado.\u003c\/p\u003e\n\u003ch2\u003eInyección de corriente\u003c\/h2\u003e\n\u003cp\u003eEl canal B puede expulsar corriente a través del microelectrodo aplicando una señal de comando al conector de entrada de estímulo. La salida resultante de la sonda será una réplica de corriente constante de la señal de entrada. Se proporcionan dos rangos de entrega de corriente: 50 nA y 500 nA o mediante una fuente externa. Esta fuente puede ser útil para entregar corrientes hiperpolarizantes para estabilizar el potencial de la membrana celular y como corriente de retención para la microiontoforesis.\u003c\/p\u003e\n\u003ch2\u003eBalance del puente\u003c\/h2\u003e\n\u003cp\u003eResta el voltaje excesivo del electrodo asociado con la entrega de corriente a través de la micropipeta de registro. Las resistencias del electrodo de hasta 1000 MΩ pueden equilibrarse en dos rangos. La señal equilibrada está disponible en los conectores de salida del panel frontal x10 o x50.\u003c\/p\u003e\n\u003ch2\u003eSalidas independientes\u003c\/h2\u003e\n\u003cp\u003eEl \u003cstrong\u003eDuo773\u003c\/strong\u003e tiene una salida para cada sonda independiente de la ganancia, filtrado o balance. Además, el \u003cstrong\u003eDuo773\u003c\/strong\u003e tiene una salida 10x y una 50x para fácil integración con la mayoría de los programas de adquisición de datos.\u003c\/p\u003e\n\u003ch2\u003eConfiguración típica\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/Duo773-setup_4017456d-121f-4e59-8d5b-9a0fbd855624.jpg?v=1765947782\" alt=\"Esquema de configuración Duo773\"\u003e\u003c\/p\u003e\n\u003cp\u003eVer \u003ca href=\"\/es\/blog\/post\/choosing-cables-and-connectors\" rel=\"noopener\" target=\"_blank\"\u003eCables y Conectores\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eVer \u003ca href=\"\/es\/blog\/post\/compare-dri-ref-reference-electrodes\" rel=\"noopener\" target=\"_blank\"\u003eelectrodos de referencia Dri-Ref\u003c\/a\u003e. \u003c\/p\u003e\n\u003ch2\u003eSoportes opcionales para amplificadores intracelulares\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/773-Holder-Options_548c4a34-c4b6-4b79-8337-dcc14934184b.jpg?v=1765947787\" alt=\"Soportes Duo773\" width=\"336\" height=\"305\"\u003e\u003c\/p\u003e\n\u003cp\u003eOtros \u003ca href=\"\/es\/blog\/post\/a-visual-catalog-of-electrode-holders\" rel=\"noopener\" target=\"_blank\"\u003esoportes para microelectrodos\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/Duo773_IM.pdf\" target=\"_self\"\u003eManual de instrucciones DUO773\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:specifications --\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #0081c2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eETAPA DE CABEZA (SONDA)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003e712P (rojo, puerto B)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003e715P (azul, puerto A)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eIMPEDANCIA DE ENTRADA DE SONDA ACTIVA\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10\u003csup\u003e11\u003c\/sup\u003e Ω\u003c\/td\u003e\n\u003ctd\u003e10\u003csup\u003e15\u003c\/sup\u003e Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGANANCIA\u003c\/td\u003e\n\u003ctd\u003ex1, x10\u003c\/td\u003e\n\u003ctd\u003ex1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eRESISTENCIA DE SALIDA \u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRANGO DE TENSIÓN DE SALIDA\u003c\/td\u003e\n\u003ctd\u003e±10 V\u003c\/td\u003e\n\u003ctd\u003e±10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eTENSIÓN MÁXIMA DE ENTRADA \u003c\/td\u003e\n\u003ctd\u003e±15 V\u003c\/td\u003e\n\u003ctd\u003e±15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCORRIENTE DE FUGA DE LA SONDA\u003c\/td\u003e\n\u003ctd\u003e5 X 10\u003csup\u003e-12\u003c\/sup\u003e A\u003c\/td\u003e\n\u003ctd\u003e10\u003csup\u003e-14\u003c\/sup\u003e A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eRANGO DE AJUSTE DE POSICIÓN DC\u003c\/td\u003e\n\u003ctd\u003e± 300 mV\u003c\/td\u003e\n\u003ctd\u003e± 300 mV \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCORRIENTE DE PRUEBA DE RESISTENCIA DEL ELECTRODO\u003c\/td\u003e\n\u003ctd\u003e1 nA\u003c\/td\u003e\n\u003ctd\u003e1 pA, 1 nA seleccionable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eCOMPENSACIÓN DE CAPACIDAD DE ENTRADA \u003c\/td\u003e\n\u003ctd\u003e+10 a -50 pF\u003c\/td\u003e\n\u003ctd\u003e0 a -10 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\" bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eRUIDO\u003cbr\u003e  Entrada en corto 712P \u003cbr\u003e  Resistencia de carbono 20 MΩ\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003e\u0026lt;50 µV p-p ancho de banda 10 kHz\u003cbr\u003e\u0026lt;200 µV p-p ancho de banda 10 kHz\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003e\u0026lt;50 µV p-p ancho de banda 10 kHz\u003cbr\u003e\u0026lt;200 µV p-p ancho de banda 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eTIEMPO DE SUBIDA\u003cbr\u003e  10-90% entrada directa señal pequeña\u003cbr\u003e  10-90% a través de 20 MΩ (-C \"encendido\")\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cbr\u003e1 µs, típico\u003cbr\u003e25 µs, típico \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eINYECCIÓN DE CORRIENTE (solo 712P)**\u003cbr\u003e  Corriente DC interna\u003cbr\u003e  Corriente comandada externamente 712P (rojo, puerto B)\u003cbr\u003e  Factor de comando de corriente externo\u003cbr\u003e  Monitor de corriente\u003cbr\u003e  Conformidad\u003cbr\u003e  Balance del puente\u003cbr\u003e  Ganancia del amplificador de puente\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003e± 50 nA rango bajo, ± 500 nA rango alto\u003cbr\u003e± 500 nA rango bajo, ±5 µA rango alto\u003cbr\u003e20 mV\/nA rango bajo, 2 mV\/nA rango alto\u003cbr\u003e100mV\/nA rango bajo, 10mV\/nA rango alto\u003cbr\u003e3V rango bajo, 10V rango alto\u003cbr\u003e0-100 MΩ, 0-1000 MΩ\u003cbr\u003ex 10, x 50\u003c\/td\u003e\n\u003ctd\u003e n\/a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eFILTRO PASA BAJOS\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e40 dB\/década, variable continuamente 1-30 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd\u003eFusible (modelos antiguos)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e120 V: 0.5 A, rápido, 0.25x1.25” USA\u003cbr\u003e230 V: 0.25 A, rápido, 0.25x1.25” USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eFusible (modelos 2019)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e120 V: 0.5 A, rápido, 5 x 20 mm métrico\u003cbr\u003e230 V: 0.25 A, rápido, 5 x 20 mm métrico\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSECCIÓN DEL MEDIDOR\u003cbr\u003e  Pantalla\u003cbr\u003e  Rangos\u003cbr\u003e  Precisión y resolución\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cbr\u003eLED de 3.5 dígitos\u003cbr\u003e200 mV, 2000 mV, 20 V, 200 nA, 2000 nA \u003cbr\u003e1 dígito\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eDIMENSIONES: \u003cbr\u003e  Instrumento\u003cbr\u003e  Sonda\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cbr\u003e17 x 5.25 x 10 in. (43 x 13 x 25 cm)\u003cbr\u003eDiámetro: 12 mm Longitud: 34 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eALIMENTACIÓN\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e95-135 V o 220-240 V, 50\/60 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003ePESO DE ENVÍO\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 lb. (7 kg) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCERTIFICACIÓN\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCE, CSA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"p1\"\u003e\u003cem\u003e* Aunque las corrientes inyectadas son “constantes,” la corriente máxima en una situación dada siempre estará limitada por la conformidad del sistema de 10 V.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cem\u003e**La etapa de cabeza 712P puede usarse en los canales A o B, sin embargo, las especificaciones de Inyección de Corriente no se aplican cuando se usa en el canal A. La etapa de cabeza 715P no puede usarse en el canal B.\u003c\/em\u003e\u003c\/p\u003e\n\u003c!-- \/section:specifications --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:references --\u003e\n\u003cp\u003ePLantas Empleadas Como Dispositivos Sensoriales | Proyectos | FP7-ICT | CORDIS | Comisión Europea. (s.f.). Recuperado el 27 de noviembre de 2018, de \u003ca href=\"https:\/\/cordis.europa.eu\/project\/rcn\/103686_en.html\"\u003ehttps:\/\/cordis.europa.eu\/project\/rcn\/103686_en.html\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eZhang, J., Chen, M., Li, B., Lv, B., Jin, K., Zheng, S., … Long, C. (2016).\u003c\/b\u003e Actividad rítmica estriatal alterada en ratones knockout de cilindromatosis debido a una inhibición gabaérgica aumentada. \u003ci\u003eNeuropharmacology\u003c\/i\u003e, \u003ci\u003e110\u003c\/i\u003e, 260–267. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.neuropharm.2016.06.021\"\u003ehttps:\/\/doi.org\/10.1016\/j.neuropharm.2016.06.021\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCros, C., Chaigne, S., Pascarel-Auclerc, C., Benoist, D., Walton, R., Pasdois, P., … Brette, F. (2016).\u003c\/b\u003e 0514 : Aislamiento de miocitos cardíacos del corazón humano. \u003ci\u003eArchives of Cardiovascular Diseases Supplements\u003c\/i\u003e, \u003ci\u003e8\u003c\/i\u003e(3), 230. \u003ca href=\"https:\/\/doi.org\/10.1016\/S1878-6480(16)30430-X\"\u003ehttps:\/\/doi.org\/10.1016\/S1878-6480(16)30430-X\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eMañé, N., Viais, R., Martínez-Cutillas, M., Gallego, D., Correia-de-Sá, P., \u0026amp; Jiménez, M. (2016).\u003c\/b\u003e Gradiente inverso de la cotransmisión inhibitoria nitrérgica y purinérgica en el colon de ratón. \u003ci\u003eActa Physiologica\u003c\/i\u003e, \u003ci\u003e216\u003c\/i\u003e(1), 120–131. \u003ca href=\"https:\/\/doi.org\/10.1111\/apha.12599\"\u003ehttps:\/\/doi.org\/10.1111\/apha.12599\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eChang, J.-H., Cheng, P.-Y., Hsu, C.-H., Chen, Y.-C., \u0026amp; Hong, P.-D. (2016).\u003c\/b\u003e Efectos del acetaminofén en la contractilidad de la aurícula izquierda. \u003ci\u003eActa Cardiologica Sinica\u003c\/i\u003e, \u003ci\u003e32\u003c\/i\u003e(4), 485–490. Recuperado de \u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/27471362\"\u003ehttp:\/\/www.ncbi.nlm.nih.gov\/pubmed\/27471362\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHuo, Q., Chen, M., He, Q., Zhang, J., Li, B., Jin, K., … Yang, L. (2016).\u003c\/b\u003e La disfunción gabaérgica cortical prefrontal contribuye a la duración aberrante del estado UP en ratones knockout de APP. \u003ci\u003eCerebral Cortex (New York, N.Y. : 1991)\u003c\/i\u003e. \u003ca href=\"https:\/\/doi.org\/10.1093\/cercor\/bhw218\"\u003ehttps:\/\/doi.org\/10.1093\/cercor\/bhw218\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSpong, K. E., Rodríguez, E. C., \u0026amp; Robertson, R. M. (2016).\u003c\/b\u003e La despolarización propagada en el cerebro de Drosophila es inducida por la inhibición de la Na+\/K+-ATPasa y mitigada por una disminución en la actividad de la proteína quinasa G. \u003ci\u003eJournal of Neurophysiology\u003c\/i\u003e, \u003ci\u003e116\u003c\/i\u003e(3).\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eMañé, N., Jiménez-Sábado, V., \u0026amp; Jiménez, M. (2016). \u003c\/b\u003eBPTU, un antagonista alostérico del receptor P2Y1, bloquea las respuestas neuromusculares inhibitorias mediadas por nervios en el tracto gastrointestinal de roedores. \u003ci\u003eNeuropharmacology\u003c\/i\u003e, \u003ci\u003e110\u003c\/i\u003e, 376–385. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.neuropharm.2016.07.033\"\u003ehttps:\/\/doi.org\/10.1016\/j.neuropharm.2016.07.033\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eBredeloux, P., Finday, I., Pasqualin, C., Yu, A., \u0026amp; Maupoil, V. (2016).\u003c\/b\u003e 0194 : Consecuencias funcionales de la activación de receptores -adrenérgicos en las venas pulmonares y aurículas izquierdas de rata. \u003ci\u003eArchives of Cardiovascular Diseases Supplements\u003c\/i\u003e, \u003ci\u003e8\u003c\/i\u003e(3). \u003ca href=\"https:\/\/doi.org\/10.1016\/S1878-6480(16)30431-1\"\u003ehttps:\/\/doi.org\/10.1016\/S1878-6480(16)30431-1\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCoskun, D., Britto, D. T., Kochian, L. V., \u0026amp; Kronzucker, H. J. (2016). \u003c\/b\u003e¿Hasta qué punto llegan los flujos iónicos? Una reevaluación del modelo de dos mecanismos para el transporte de K+ en raíces de plantas. \u003ci\u003ePlant Science\u003c\/i\u003e, \u003ci\u003e243\u003c\/i\u003e, 96–104. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.plantsci.2015.12.003\"\u003ehttps:\/\/doi.org\/10.1016\/j.plantsci.2015.12.003\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eMagown, P., Shettar, B., Zhang, Y., \u0026amp; Rafuse, V. F. (2015).\u003c\/b\u003e Activación óptica directa de fibras musculares esqueléticas controla eficientemente la contracción muscular y atenúa la atrofia por denervación. \u003ci\u003eNature Communications\u003c\/i\u003e, \u003ci\u003e6\u003c\/i\u003e(1), 8506. \u003ca href=\"https:\/\/doi.org\/10.1038\/ncomms9506\"\u003ehttps:\/\/doi.org\/10.1038\/ncomms9506\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eYi, F., Ling, T.-Y., Lu, T., Wang, X.-L., Li, J., Claycomb, W. C., … Lee, H.-C. (2015).\u003c\/b\u003e Regulación a la baja de los canales de potasio activados por calcio de pequeña conductancia en las aurículas de ratones diabéticos. \u003ci\u003eThe Journal of Biological Chemistry\u003c\/i\u003e, \u003ci\u003e290\u003c\/i\u003e(11), 7016–7026. \u003ca href=\"https:\/\/doi.org\/10.1074\/jbc.M114.607952\"\u003ehttps:\/\/doi.org\/10.1074\/jbc.M114.607952\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003evan der Schoot, C., \u0026amp; Rinne, P. L. H. (2015).\u003c\/b\u003e Mapeo de campos simplásmicos en el meristemo apical del brote usando iontoforesis y mediciones de potencial de membrana (pp. 157–171). \u003ca href=\"https:\/\/doi.org\/10.1007\/978-1-4939-1523-1_11\"\u003ehttps:\/\/doi.org\/10.1007\/978-1-4939-1523-1_11\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eChatterjee, S. K., Das, S., Maharatna, K., Masi, E., Santopolo, L., Mancuso, S., \u0026amp; Vitaletti, A. (2015).\u003c\/b\u003e Explorando estrategias para la clasificación de estímulos externos usando características estadísticas de la respuesta eléctrica de plantas. \u003ci\u003eJournal of The Royal Society Interface\u003c\/i\u003e, \u003ci\u003e12\u003c\/i\u003e(104), 20141225–20141225. \u003ca href=\"https:\/\/doi.org\/10.1098\/rsif.2014.1225\"\u003ehttps:\/\/doi.org\/10.1098\/rsif.2014.1225\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePan, X., Zhang, Z., Huang, Y.-Y., Zhao, J., \u0026amp; Wang, L. (2015).\u003c\/b\u003e Efectos electrofisiológicos de la dexmedetomidina en los nodos sinoauriculares de conejos. \u003ci\u003eActa Cardiologica Sinica\u003c\/i\u003e, \u003ci\u003e31\u003c\/i\u003e(6), 543–549. Recuperado de \u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/27122920\"\u003ehttp:\/\/www.ncbi.nlm.nih.gov\/pubmed\/27122920\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHuang, J., Dosdall, D. J., Cheng, K., Li, L., Rogers, J. M., \u0026amp; Ideker, R. E. (2014).\u003c\/b\u003e La importancia de la activación de Purkinje en la fibrilación ventricular de larga duración. \u003ci\u003eJournal of the American Heart Association\u003c\/i\u003e, \u003ci\u003e3\u003c\/i\u003e(1), e000495. \u003ca href=\"https:\/\/doi.org\/10.1161\/JAHA.113.000495\"\u003ehttps:\/\/doi.org\/10.1161\/JAHA.113.000495\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAltamirano, F., Eltit, J. M., Robin, G., Linares, N., Ding, X., Pessah, I. N., … López, J. R. (2014).\u003c\/b\u003e El influjo de Ca \u003csup\u003e2+\u003c\/sup\u003e a través del intercambiador Na \u003csup\u003e+\u003c\/sup\u003e \/Ca \u003csup\u003e2+\u003c\/sup\u003e está aumentado en el músculo esquelético con hipertermia maligna. \u003ci\u003eJournal of Biological Chemistry\u003c\/i\u003e, \u003ci\u003e289\u003c\/i\u003e(27), 19180–19190. \u003ca href=\"https:\/\/doi.org\/10.1074\/jbc.M114.550764\"\u003ehttps:\/\/doi.org\/10.1074\/jbc.M114.550764\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAltamirano, F., Perez, C. F., Liu, M., Widrick, J., Barton, E. R., Allen, P. D., … Lopez, J. R. (2014).\u003c\/b\u003e La aceleración periódica de todo el cuerpo es una terapia eficaz para mejorar la distrofia muscular en ratones mdx. \u003ci\u003ePLoS ONE\u003c\/i\u003e, \u003ci\u003e9\u003c\/i\u003e(9), e106590. \u003ca href=\"https:\/\/doi.org\/10.1371\/journal.pone.0106590\"\u003ehttps:\/\/doi.org\/10.1371\/journal.pone.0106590\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eLiu, D.-H., Huang, X., Guo, X., Meng, X.-M., Wu, Y.-S., Lu, H.-L., … Xu, W.-X. (2014).\u003c\/b\u003e Remodelación de canales de potasio dependientes de voltaje en la hipertrofia del músculo liso intestinal murino inducida por obstrucción parcial. \u003ci\u003ePLoS ONE\u003c\/i\u003e, \u003ci\u003e9\u003c\/i\u003e(2), e86109. \u003ca href=\"https:\/\/doi.org\/10.1371\/journal.pone.0086109\"\u003ehttps:\/\/doi.org\/10.1371\/journal.pone.0086109\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eMousavi, S. A. R., Chauvin, A., Pascaud, F., Kellenberger, S., \u0026amp; Farmer, E. E. (2013). \u003c\/b\u003eLos genes GLUTAMATE RECEPTOR-LIKE median la señalización de heridas de hoja a hoja. \u003ci\u003eNature\u003c\/i\u003e, \u003ci\u003e500\u003c\/i\u003e(7463), 422–426. \u003ca href=\"https:\/\/doi.org\/10.1038\/nature12478\"\u003ehttps:\/\/doi.org\/10.1038\/nature12478\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAltamirano, F., Valladares, D., Henríquez-Olguín, C., Casas, M., López, J. R., Allen, P. D., \u0026amp; Jaimovich, E. (2013).\u003c\/b\u003e El tratamiento con nifedipino reduce la concentración de calcio en reposo, la expresión génica oxidativa y apoptótica, y mejora la función muscular en ratones mdx con distrofia. \u003ci\u003ePLoS ONE\u003c\/i\u003e, \u003ci\u003e8\u003c\/i\u003e(12), e81222. \u003ca href=\"https:\/\/doi.org\/10.1371\/journal.pone.0081222\"\u003ehttps:\/\/doi.org\/10.1371\/journal.pone.0081222\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eChen, J., Du, L., Xiao, Y.-T., \u0026amp; Cai, W. (2013).\u003c\/b\u003e Disrupción de las redes de células intersticiales de Cajal tras una resección masiva del intestino delgado. \u003ci\u003eWorld Journal of Gastroenterology\u003c\/i\u003e, \u003ci\u003e19\u003c\/i\u003e(22), 3415. \u003ca href=\"https:\/\/doi.org\/10.3748\/wjg.v19.i22.3415\"\u003ehttps:\/\/doi.org\/10.3748\/wjg.v19.i22.3415\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eEltit, J. M., Ding, X., Pessah, I. N., Allen, P. D., \u0026amp; Lopez, J. R. (2013).\u003c\/b\u003e Los canales catiónicos sarcolemales no específicos son críticos para la patogénesis de la hipertermia maligna. \u003ci\u003eThe FASEB Journal\u003c\/i\u003e, \u003ci\u003e27\u003c\/i\u003e(3), 991–1000. \u003ca href=\"https:\/\/doi.org\/10.1096\/fj.12-218354\"\u003ehttps:\/\/doi.org\/10.1096\/fj.12-218354\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHafke, J. B., Höll, S.-R., Kühn, C., \u0026amp; van Bel, A. J. E. (2013).\u003c\/b\u003e Enfoque electrofisiológico para determinar parámetros cinéticos de la captación de sacarosa por elementos cribosos individuales o células del parénquima del floema en plantas intactas de Vicia faba. \u003ci\u003eFrontiers in Plant Science\u003c\/i\u003e, \u003ci\u003e4\u003c\/i\u003e, 274. \u003ca href=\"https:\/\/doi.org\/10.3389\/fpls.2013.00274\"\u003ehttps:\/\/doi.org\/10.3389\/fpls.2013.00274\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eGuo, X., Huang, X., Wu, Y., Liu, D., Lu, H., Kim, Y., … Xu, W. (2012).\u003c\/b\u003e La regulación a la baja de la biosíntesis de sulfuro de hidrógeno acompaña la disfunción de las células intersticiales de Cajal murinas en la obstrucción ileal parcial. \u003ci\u003ePLoS ONE\u003c\/i\u003e, \u003ci\u003e7\u003c\/i\u003e(11), e48249. \u003ca href=\"https:\/\/doi.org\/10.1371\/journal.pone.0048249\"\u003ehttps:\/\/doi.org\/10.1371\/journal.pone.0048249\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eUEHLEIN, N., SPERLING, H., HECKWOLF, M., \u0026amp; KALDENHOFF, R. (2012).\u003c\/b\u003e La acuaporina PIP1;2 de Arabidopsis regula la captación celular de CO2. \u003ci\u003ePlant, Cell \u0026amp; Environment\u003c\/i\u003e, \u003ci\u003e35\u003c\/i\u003e(6), 1077–1083. \u003ca href=\"https:\/\/doi.org\/10.1111\/j.1365-3040.2011.02473.x\"\u003ehttps:\/\/doi.org\/10.1111\/j.1365-3040.2011.02473.x\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAltamirano, F., López, J. R., Henríquez, C., Molinski, T., Allen, P. D., \u0026amp; Jaimovich, E. (2012).\u003c\/b\u003e El aumento del calcio intracelular en reposo modula la expresión génica de la sintasa inducible de óxido nítrico dependiente de NF-κB en miotubos esqueléticos distróficos \u003ci\u003emdx\u003c\/i\u003e. \u003ci\u003eJournal of Biological Chemistry\u003c\/i\u003e, \u003ci\u003e287\u003c\/i\u003e(25), 20876–20887. \u003ca href=\"https:\/\/doi.org\/10.1074\/jbc.M112.344929\"\u003ehttps:\/\/doi.org\/10.1074\/jbc.M112.344929\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHamaguchi, K., Yamamoto, N., Nakagawa, T., Furuyashiki, T., Narumiya, S., \u0026amp; Ito, J. (2012).\u003c\/b\u003e Papel del receptor tipo PGE 4 en la función auditiva y la pérdida auditiva inducida por ruido en ratones. \u003ci\u003eNeuropharmacology\u003c\/i\u003e, \u003ci\u003e62\u003c\/i\u003e(4), 1841–1847. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.neuropharm.2011.12.007\"\u003ehttps:\/\/doi.org\/10.1016\/j.neuropharm.2011.12.007\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eArmstrong, G. A. B., Rodríguez, E. C., \u0026amp; Meldrum Robertson, R. (2012).\u003c\/b\u003e La aclimatación al frío modula la homeostasis de K+ en el cerebro de Drosophila melanogaster durante el coma por frío. \u003ci\u003eJournal of Insect Physiology\u003c\/i\u003e, \u003ci\u003e58\u003c\/i\u003e(11), 1511–1516. \u003ca href=\"https:\/\/doi.org\/10.1016\/J.JINSPHYS.2012.09.006\"\u003ehttps:\/\/doi.org\/10.1016\/J.JINSPHYS.2012.09.006\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTsai, C.-F., Chen, Y.-C., Lin, Y.-K., Chen, S.-A., \u0026amp; Chen, Y.-J. (2011).\u003c\/b\u003e Efectos electromecánicos del inhibidor directo de la renina (aliskiren) en la vena pulmonar y el atrio. \u003ci\u003eBasic Research in Cardiology\u003c\/i\u003e, \u003ci\u003e106\u003c\/i\u003e(6), 979–993. \u003ca href=\"https:\/\/doi.org\/10.1007\/s00395-011-0206-8\"\u003ehttps:\/\/doi.org\/10.1007\/s00395-011-0206-8\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHan, Y., Huang, X., Guo, X., Wu, Y., Liu, D., Lu, H., … Xu, W. (2011). \u003c\/b\u003e Evidencia de que el sulfuro de hidrógeno endógeno ejerce un efecto excitatorio sobre la motilidad gástrica en ratones. \u003ci\u003eEuropean Journal of Pharmacology\u003c\/i\u003e, \u003ci\u003e673\u003c\/i\u003e(1–3), 85–95. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.ejphar.2011.10.018\"\u003ehttps:\/\/doi.org\/10.1016\/j.ejphar.2011.10.018\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHaugan, B. M., Halberg, K. A., Jespersen, Å., Prehn, L. R., \u0026amp; Møbjerg, N. (2010).\u003c\/b\u003e Caracterización funcional del uréter primario de vertebrados: Estructura y mecanismos de transporte iónico del conducto pronefrico en larvas de ajolote (Amphibia). \u003ci\u003eBMC Developmental Biology\u003c\/i\u003e, \u003ci\u003e10\u003c\/i\u003e(1), 56. \u003ca href=\"https:\/\/doi.org\/10.1186\/1471-213X-10-56\"\u003ehttps:\/\/doi.org\/10.1186\/1471-213X-10-56\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eLi, H., Ding, X., Lopez, J. R., Takeshima, H., Ma, J., Allen, P. D., \u0026amp; Eltit, J. M. (2010).\u003c\/b\u003e La entrada de Ca \u003csup\u003e2+\u003c\/sup\u003e en reposo mediada por Orai1 deteriorada reduce el [Ca \u003csup\u003e2+\u003c\/sup\u003e ] citosólico y la carga de Ca \u003csup\u003e2+\u003c\/sup\u003e en el retículo sarcoplásmico en miotubos en reposo con eliminación de junctophilin 1. \u003ci\u003eJournal of Biological Chemistry\u003c\/i\u003e, \u003ci\u003e285\u003c\/i\u003e(50), 39171–39179. \u003ca href=\"https:\/\/doi.org\/10.1074\/jbc.M110.149690\"\u003ehttps:\/\/doi.org\/10.1074\/jbc.M110.149690\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eRuonala, R., Rinne, P. L. H., Kangasjarvi, J., \u0026amp; van der Schoot, C. (2008). \u003c\/b\u003eLa expresión de CENL1 en el meristemo de la costilla afecta la elongación del tallo y la transición a la dormancia en Populus. \u003ci\u003eTHE PLANT CELL ONLINE\u003c\/i\u003e, \u003ci\u003e20\u003c\/i\u003e(1), 59–74. \u003ca href=\"https:\/\/doi.org\/10.1105\/tpc.107.056721\"\u003ehttps:\/\/doi.org\/10.1105\/tpc.107.056721\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eKeller, C. P., Barkosky, R. R., Seil, J. E., Mazurek, S. A., \u0026amp; Grundstad, M. L. (2008).\u003c\/b\u003e La respuesta eléctrica de las raíces de Phaseolus vulgaris a la exposición abrupta a hidroquinona. \u003ci\u003ePlant Signaling \u0026amp; Behavior\u003c\/i\u003e, \u003ci\u003e3\u003c\/i\u003e(9), 633–640. Recuperado de \u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/19513254\"\u003ehttp:\/\/www.ncbi.nlm.nih.gov\/pubmed\/19513254\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eMcDonnell, B., Hamilton, R., Fong, M., Ward, S. M., \u0026amp; Keef, K. D. (2008). \u003c\/b\u003e Evidencia funcional de transmisión neuromuscular purinérgica inhibitoria en el esfínter anal interno de ratón. \u003ci\u003eAmerican Journal of Physiology-Gastrointestinal and Liver Physiology\u003c\/i\u003e, \u003ci\u003e294\u003c\/i\u003e(4), G1041–G1051. \u003ca href=\"https:\/\/doi.org\/10.1152\/ajpgi.00356.2007\"\u003ehttps:\/\/doi.org\/10.1152\/ajpgi.00356.2007\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eLew, R. R. (2007).\u003c\/b\u003e Corrientes iónicas y flujos de iones en hifas de Neurospora crassa. \u003ci\u003eJournal of Experimental Botany\u003c\/i\u003e, \u003ci\u003e58\u003c\/i\u003e(12), 3475–3481. \u003ca href=\"https:\/\/doi.org\/10.1093\/jxb\/erm204\"\u003ehttps:\/\/doi.org\/10.1093\/jxb\/erm204\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePatterson, E., Po, S. S., Scherlag, B. J., \u0026amp; Lazzara, R. (2005).\u003c\/b\u003e Disparo desencadenado en venas pulmonares iniciado por estimulación nerviosa autónoma in vitro. \u003ci\u003eHeart Rhythm\u003c\/i\u003e, \u003ci\u003e2\u003c\/i\u003e(6), 624–631. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.hrthm.2005.02.012\"\u003ehttps:\/\/doi.org\/10.1016\/j.hrthm.2005.02.012\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCho, S. Y., Beckett, E. A., Baker, S. A., Han, I., Park, K. J., Monaghan, K., … Koh, S. D. (2005).\u003c\/b\u003e Una conductancia de potasio sensible al pH (TASK) y su función en el tracto gastrointestinal murino. \u003ci\u003eThe Journal of Physiology\u003c\/i\u003e, \u003ci\u003e565\u003c\/i\u003e(Pt 1), 243–259. \u003ca href=\"https:\/\/doi.org\/10.1113\/jphysiol.2005.084574\"\u003ehttps:\/\/doi.org\/10.1113\/jphysiol.2005.084574\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eKreindler, J. L., Jackson, A. D., Kemp, P. A., Bridges, R. J., \u0026amp; Danahay, H. (2005). \u003c\/b\u003eInhibición de la secreción de cloruro en células epiteliales bronquiales humanas por extracto de humo de cigarrillo. \u003ci\u003eAmerican Journal of Physiology-Lung Cellular and Molecular Physiology\u003c\/i\u003e, \u003ci\u003e288\u003c\/i\u003e(5), L894–L902. \u003ca href=\"https:\/\/doi.org\/10.1152\/ajplung.00376.2004\"\u003ehttps:\/\/doi.org\/10.1152\/ajplung.00376.2004\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eVerheule, S., Sato, T., Everett, T., Engle, S. K., Otten, D., Rubart-von der Lohe, M., … Olgin, J. E. (2004).\u003c\/b\u003e Mayor vulnerabilidad a la fibrilación auricular en ratones transgénicos con fibrosis auricular selectiva causada por sobreexpresión de TGF-β1. \u003ci\u003eCirculation Research\u003c\/i\u003e, \u003ci\u003e94\u003c\/i\u003e(11), 1458–1465. \u003ca href=\"https:\/\/doi.org\/10.1161\/01.RES.0000129579.59664.9d\"\u003ehttps:\/\/doi.org\/10.1161\/01.RES.0000129579.59664.9d\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHwang, H.-R., Shen, Y.-F., Chen, Y.-C., Liu, C.-P., \u0026amp; Lin, C.-I. (2004). \u003c\/b\u003eEfectos del ácido ciclopiazónico en actividades desencadenadas en músculo ventricular y cardiomiocitos aislados de corazones de hámster. \u003ci\u003eThe Chinese Journal of Physiology\u003c\/i\u003e, \u003ci\u003e47\u003c\/i\u003e(3), 137–142. Recuperado de \u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/15612531\"\u003ehttp:\/\/www.ncbi.nlm.nih.gov\/pubmed\/15612531\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eErmilov, L. G., Schmalz, P. F., Miller, S. M., \u0026amp; Szurszewski, J. H. (2004).\u003c\/b\u003e Modulación por PACAP del reflejo colon-ganglio mesentérico inferior en cobayos. \u003ci\u003eThe Journal of Physiology\u003c\/i\u003e, \u003ci\u003e560\u003c\/i\u003e(1), 231–247. \u003ca href=\"https:\/\/doi.org\/10.1113\/jphysiol.2004.070060\"\u003ehttps:\/\/doi.org\/10.1113\/jphysiol.2004.070060\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eBruusgaard, J. C., Liestøl, K., Ekmark, M., Kollstad, K., \u0026amp; Gundersen, K. (2003).\u003c\/b\u003e Número y distribución espacial de núcleos en las fibras musculares de ratones normales estudiados in vivo. \u003ci\u003eThe Journal of Physiology\u003c\/i\u003e, \u003ci\u003e551\u003c\/i\u003e(Pt 2), 467–478. \u003ca href=\"https:\/\/doi.org\/10.1113\/jphysiol.2003.045328\"\u003ehttps:\/\/doi.org\/10.1113\/jphysiol.2003.045328\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eLennon, V. A., Ermilov, L. G., Szurszewski, J. H., \u0026amp; Vernino, S. (2003).\u003c\/b\u003e La inmunización con receptor neuronal nicotínico de acetilcolina induce enfermedad autoinmune neurológica. \u003ci\u003eThe Journal of Clinical Investigation\u003c\/i\u003e, \u003ci\u003e111\u003c\/i\u003e(6), 907–913. \u003ca href=\"https:\/\/doi.org\/10.1172\/JCI17429\"\u003ehttps:\/\/doi.org\/10.1172\/JCI17429\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eChen, Y. J., Chen, S. A., Chang, M. S., \u0026amp; Lin, C. I. (2000).\u003c\/b\u003e Actividad arritmogénica del músculo cardíaco en las venas pulmonares del perro: implicación para la génesis de la fibrilación auricular. \u003ci\u003eCardiovascular Research\u003c\/i\u003e, \u003ci\u003e48\u003c\/i\u003e(2), 265–273. Recuperado de \u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/11054473\"\u003ehttp:\/\/www.ncbi.nlm.nih.gov\/pubmed\/11054473\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eWard, S. M., Beckett, E. A., Wang, X., Baker, F., Khoyi, M., \u0026amp; Sanders, K. M. (2000).\u003c\/b\u003e Las células intersticiales de Cajal median la neurotransmisión colinérgica de las neuronas motoras entéricas. \u003ci\u003eThe Journal of Neuroscience : The Official Journal of the Society for Neuroscience\u003c\/i\u003e, \u003ci\u003e20\u003c\/i\u003e(4), 1393–1403. Recuperado de \u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/10662830\"\u003ehttp:\/\/www.ncbi.nlm.nih.gov\/pubmed\/10662830\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eKilb, W., \u0026amp; Schlue, W. R. (1999).\u003c\/b\u003e Mecanismo de la acidificación intracelular inducida por kainato en neuronas Retzius de sanguijuela. \u003ci\u003eBrain Research\u003c\/i\u003e, \u003ci\u003e824\u003c\/i\u003e(2), 168–182. Recuperado de \u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/10196447\"\u003ehttp:\/\/www.ncbi.nlm.nih.gov\/pubmed\/10196447\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHara, M., Shvilkin, A., Rosen, M. R., Danilo, P., \u0026amp; Boyden, P. A. (1999).\u003c\/b\u003e Potenciales de acción en estado estacionario y no estacionario en el atrio fibrilante canino: adaptación anormal a la frecuencia y sus posibles mecanismos. \u003ci\u003eCardiovascular Research\u003c\/i\u003e, \u003ci\u003e42\u003c\/i\u003e(2), 455–469. Recuperado de \u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/10533581\"\u003ehttp:\/\/www.ncbi.nlm.nih.gov\/pubmed\/10533581\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eMuto, S., Asano, Y., Seldin, D., \u0026amp; Giebisch, G. (1999).\u003c\/b\u003e La bomba de Na+ basolateral modula las conductancias apicales de Na+ y K+ en los conductos colectores corticales de conejo. \u003ci\u003eThe American Journal of Physiology\u003c\/i\u003e, \u003ci\u003e276\u003c\/i\u003e(1 Pt 2), F143-58. Recuperado de \u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/9887090\"\u003ehttp:\/\/www.ncbi.nlm.nih.gov\/pubmed\/9887090\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHara, M., Danilo, P. R., \u0026amp; Rosen, M. R. (1998).\u003c\/b\u003e Efectos de los esteroides gonadales en la repolarización ventricular y en la respuesta a E4031. \u003ci\u003eUndefined\u003c\/i\u003e. Recuperado de \u003ca href=\"https:\/\/www.semanticscholar.org\/paper\/Effects-of-gonadal-steroids-on-ventricular-and-on-Hara-Danilo\/1be02ac45630bf87ec224f8484890f68981572e3\"\u003ehttps:\/\/www.semanticscholar.org\/paper\/Effects-of-gonadal-steroids-on-ventricular-and-on-Hara-Danilo\/1be02ac45630bf87ec224f8484890f68981572e3\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eWelsh, D. G., Jackson, W. F., \u0026amp; Segal, S. S. (1998).\u003c\/b\u003e El oxígeno induce acoplamiento electromecánico en células musculares lisas arteriolares: un papel para los canales de Ca \u003csup\u003e2+\u003c\/sup\u003e tipo L. \u003ci\u003eAmerican Journal of Physiology-Heart and Circulatory Physiology\u003c\/i\u003e, \u003ci\u003e274\u003c\/i\u003e(6), H2018–H2024. \u003ca href=\"https:\/\/doi.org\/10.1152\/ajpheart.1998.274.6.H2018\"\u003ehttps:\/\/doi.org\/10.1152\/ajpheart.1998.274.6.H2018\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eKuwana, S., Okada, Y., \u0026amp; Natsui, T. (1998).\u003c\/b\u003e Efectos del calcio y magnesio extracelulares en el control respiratorio central en el tronco encefálico-médula espinal de ratas neonatas. \u003ci\u003eBrain Research\u003c\/i\u003e, \u003ci\u003e786\u003c\/i\u003e(1–2), 194–204. Recuperado de \u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/9555011\"\u003ehttp:\/\/www.ncbi.nlm.nih.gov\/pubmed\/9555011\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eBotha, C. E. J., \u0026amp; Cross, R. H. M. (1997).\u003c\/b\u003e Frecuencia de plasmodesmos en relación con el transporte a corta distancia y la carga de floema en hojas de cebada (Hordeum vulgare). El floema no se carga directamente desde el simplasto. \u003ci\u003ePhysiologia Plantarum\u003c\/i\u003e, \u003ci\u003e99\u003c\/i\u003e(3), 355–362. \u003ca href=\"https:\/\/doi.org\/10.1111\/j.1399-3054.1997.tb00547.x\"\u003ehttps:\/\/doi.org\/10.1111\/j.1399-3054.1997.tb00547.x\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eKeef, K. D., Murray, D. C., Sanders, K. M., \u0026amp; Smith, T. K. (1997).\u003c\/b\u003e La liberación basal de óxido nítrico induce un patrón motor oscilatorio en el colon canino. \u003ci\u003eThe Journal of Physiology\u003c\/i\u003e, \u003ci\u003e499 ( Pt 3)\u003c\/i\u003e(Pt 3), 773–786. Recuperado de \u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/9130172\"\u003ehttp:\/\/www.ncbi.nlm.nih.gov\/pubmed\/9130172\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFelle, H. H., \u0026amp; Hepler, P. K. (1997).\u003c\/b\u003e El gradiente de concentración citosólica de Ca2+ en pelos radiculares de Sinapis alba revelado por pruebas con microelectrodos selectivos de Ca2+ e imágenes de razón Fura-Dextran. \u003ci\u003ePlant Physiology\u003c\/i\u003e, \u003ci\u003e114\u003c\/i\u003e(1), 39–45. Recuperado de \u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/12223687\"\u003ehttp:\/\/www.ncbi.nlm.nih.gov\/pubmed\/12223687\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eLu, G., Qian, X., Berezin, I., Telford, G. L., Huizinga, J. D., \u0026amp; Sarna, S. K. (1997). \u003c\/b\u003eLa inflamación modula la actividad mioeléctrica y contráctil colónica in vitro y las células intersticiales de Cajal. \u003ci\u003eThe American Journal of Physiology\u003c\/i\u003e, \u003ci\u003e273\u003c\/i\u003e(6 Pt 1), G1233-45. Recuperado de \u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/9435548\"\u003ehttp:\/\/www.ncbi.nlm.nih.gov\/pubmed\/9435548\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eWang, R., \u0026amp; Crawford, N. M. (1996).\u003c\/b\u003e Identificación genética de un gen involucrado en el transporte constitutivo de alta afinidad de nitrato en plantas superiores. \u003ci\u003eProceedings of the National Academy of Sciences of the United States of America\u003c\/i\u003e, \u003ci\u003e93\u003c\/i\u003e(17), 9297–9301. Recuperado de \u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/8799195\"\u003ehttp:\/\/www.ncbi.nlm.nih.gov\/pubmed\/8799195\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eWoodruff, R. I., \u0026amp; Telfer, W. H. (1994).\u003c\/b\u003e Gradiente en estado estacionario de la actividad de iones calcio a través de los puentes intercelulares que conectan ovocitos y células nodrizas en Hyalophora cecropia. \u003ci\u003eArchives of Insect Biochemistry and Physiology\u003c\/i\u003e, \u003ci\u003e25\u003c\/i\u003e(1), 9–20. \u003ca href=\"https:\/\/doi.org\/10.1002\/arch.940250103\"\u003ehttps:\/\/doi.org\/10.1002\/arch.940250103\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eKeef, K. D., Du, C., Ward, S. M., McGregor, B., \u0026amp; Sanders, K. M. (1993).\u003c\/b\u003e Regulación neural inhibitoria entérica del músculo circular del colon humano: papel del óxido nítrico. \u003ci\u003eGastroenterology\u003c\/i\u003e, \u003ci\u003e105\u003c\/i\u003e(4), 1009–1016. \u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/8104837\/\" target=\"_blank\" rel=\"noopener\"\u003ehttps:\/\/pubmed.ncbi.nlm.nih.gov\/8104837\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eStark, M. E., Bauer, A. J., \u0026amp; Szurszewski, J. H. (1991).\u003c\/b\u003e Efecto del óxido nítrico en el músculo circular del intestino delgado canino. \u003ci\u003eThe Journal of Physiology\u003c\/i\u003e, \u003ci\u003e444\u003c\/i\u003e, 743–761. Recuperado de \u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/1688034\"\u003ehttp:\/\/www.ncbi.nlm.nih.gov\/pubmed\/1688034\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eButt, A. M., Jones, H. C., \u0026amp; Abbott, N. J. (1990). \u003c\/b\u003eResistencia eléctrica a través de la barrera hematoencefálica en ratas anestesiadas: un estudio del desarrollo. \u003ci\u003eThe Journal of Physiology\u003c\/i\u003e, \u003ci\u003e429\u003c\/i\u003e, 47–62. Recuperado de \u003ca href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/2277354\"\u003ehttp:\/\/www.ncbi.nlm.nih.gov\/pubmed\/2277354\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eWright, J. P., Fisher, D. B., Kelling, F., Furch, A. C. U., Gaupels, F., \u0026amp; Bel, A. J. E. van. (1981).\u003c\/b\u003e Medición del potencial de la membrana del tubo criboso. \u003ci\u003ePLANT PHYSIOLOGY\u003c\/i\u003e, \u003ci\u003e67\u003c\/i\u003e(4), 845–848. \u003ca href=\"https:\/\/doi.org\/10.1104\/pp.67.4.845\"\u003ehttps:\/\/doi.org\/10.1104\/pp.67.4.845\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266237206618,"sku":"SYS-773","price":9500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/sys-773_edffecb7-43c9-4c42-8873-7ad7f58b99e7.jpg?v=1766399546"},{"product_id":"sys-a362-a362-battery-charger","title":"Cargador de Baterías A362","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eRequerido para \u003cstrong\u003eA320R\u003c\/strong\u003e, \u003ca href=\"https:\/\/www.wpiinc.com\/var-2273-constant-current-stimulus-isolator\"\u003e\u003cstrong\u003eA365R\u003c\/strong\u003e \u003c\/a\u003ey \u003ca href=\"https:\/\/www.wpiinc.com\/var-2275-linear-stimulus-isolator\"\u003e\u003cstrong\u003eA395R\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003eRecarga el paquete de baterías de níquel-cadmio o NiMH de alto voltaje en el \u003cstrong\u003eA320R\u003c\/strong\u003e, \u003ca href=\"https:\/\/www.wpiinc.com\/var-2273-constant-current-stimulus-isolator\"\u003e\u003cstrong\u003eA365R\u003c\/strong\u003e \u003c\/a\u003ey \u003ca href=\"https:\/\/www.wpiinc.com\/var-2275-linear-stimulus-isolator\"\u003e\u003cstrong\u003eA395R\u003c\/strong\u003e\u003c\/a\u003eLa lámpara LED indica el estado de carga. La lámpara LED indica el estado de carga. Carga completa durante la noche.\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDimensiones: 2.8 x 4.1 x 5\" (7x10x13 cm) \u003c\/li\u003e\r\n\u003cli\u003ePeso de envío: 4 lb. (1.8 kg)\u003c\/li\u003e\r\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/A362-IM.pdf\" target=\"_self\"\u003eManual de instrucciones A362\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003cp\u003eRequerido para \u003ca href=\"\/es\/var-2271-stimulator-isolator-for-precise-current-delivery\"\u003e\u003cstrong\u003eA320R\u003c\/strong\u003e\u003c\/a\u003e, \u003ca href=\"\/es\/var-2273-constant-current-stimulus-isolator\"\u003e\u003cstrong\u003eA365R\u003c\/strong\u003e \u003c\/a\u003ey \u003ca href=\"\/es\/var-2275-linear-stimulus-isolator\"\u003e\u003cstrong\u003eA395R\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266237435994,"sku":"SYS-A362","price":850.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/a362_1_ee75b187-2e23-43cb-af0b-5c440b567801.jpg?v=1766399576"},{"product_id":"sys-a382-battery-charger","title":"Cargador de Batería","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eCargador innovador de 3 pasos que emplea cargas rápida, media y de mantenimiento\u003c\/li\u003e\r\n\u003cli\u003eCarga con una corriente baja y segura, extendiendo considerablemente la vida útil de la batería\u003c\/li\u003e\r\n\u003cli\u003ePara usar solo con baterías en el Aislador de Estímulos A385\u003c\/li\u003e\r\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/A382-IM.pdf\"\u003eManual de instrucciones A382\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ePOTENCIA\u003c\/td\u003e\r\n\u003ctd\u003e95-135 V o 220-240 V, 50\/60 Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eDIMENSIONES\u003c\/td\u003e\r\n\u003ctd\u003e8.5 x 3.5 x 5 pulg (22 x 9 x 12 cm)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ePESO DE ENVÍO\u003c\/td\u003e\r\n\u003ctd\u003e5 lb (2.3 kg)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266239172698,"sku":"SYS-A382","price":975.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/a382-front_e2948864-4042-4264-8ad1-ce6b91ddd557.jpg?v=1766399584"},{"product_id":"sys-bp1-blood-pressure-monitor","title":"Monitor de Presión Arterial","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMonitorea presión, fuerza, temperatura\u003c\/li\u003e\n\u003cli\u003eMonitorea la presión arterial o venosa en animales\u003c\/li\u003e\n\u003cli\u003eMuestra la presión arterial sistólica, diastólica o promedio\u003c\/li\u003e\n\u003cli\u003eSYS-BP1 no incluye el transductor BLPR2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBeneficios\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBLPR2 puede usarse para la medición directa de la presión arterial y venosa en vasos sanguíneos de animales\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoreo invasivo de la presión arterial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eBP1 acepta el transductor de presión arterial BLPR2 de WPI (derecha) así como otros transductores de presión arterial. Un monitor de audio proporciona una señal con tono y amplitud variables, permitiéndole escuchar los cambios en la presión arterial. La pantalla LCD digital muestra valores promedio o pico de la señal de 0 a 1999 mV. Con un manómetro opcional (no incluido — vea \u003ca href=\"\/es\/var-3529-pressure-manometer\"\u003e\u003cstrong\u003ePM015D\/R\u003c\/strong\u003e\u003c\/a\u003e), puede calibrar la pantalla para leer en mmHg. El conector de salida para grabadora permite la conexión directa a una grabadora de pluma, osciloscopio o computadora mediante un sistema de adquisición de datos.\u003c\/p\u003e\n\u003cp\u003eSuministrado estéril, BLPR2 es preciso, lineal y estable con la temperatura. Puede ser esterilizado en frío con Rapicide OPA o un bactericida similar.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/es\/blpr2-blood-pressure-transducer-cable\"\u003eBLPR2\u003c\/a\u003e viene equipado con un cable de 12' y conector compatible con la unidad de acondicionamiento de señal de cuatro canales TBM4M Transbridge de WPI y el monitor de presión arterial BP1 de un solo canal. El cable tiene un conector de bloqueo resistente a la humedad. Un lumen continuo y uniforme elimina lugares donde se puedan formar y alojar burbujas. El camino del fluido transparente es fácil de inspeccionar. Fácil de montar — el cuerpo ranurado del transductor acepta una correa de Velcro.\u003c\/p\u003e\n\u003cp\u003ePara facilitar la configuración y operación, se incluye un stopcock de cuatro vías que permite un llenado, enjuague y puesta a cero del transductor de forma sencilla. Normalmente, el stopcock se ubica entre el transductor y el catéter del animal, donde puede usarse para poner a cero, enjuagar o eliminar burbujas del transductor rápidamente.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/BP-1-IM.pdf\" target=\"_self\"\u003eManual de instrucciones BP-1\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable border=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr bgcolor=\"#e4e4e4\"\u003e\n\u003ctd\u003eAmplificación\u003c\/td\u003e\n\u003ctd\u003ex1, x10, x100, variable (x5-x1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAncho de banda, señal pequeña (-3dB)\u003c\/td\u003e\n\u003ctd\u003e300kHz (x1)\u003cbr\u003e 30kHz (x10)\u003cbr\u003e 3kHz (x100)\u003cbr\u003e 0.3kHz (x1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e4e4e4\"\u003e\n\u003ctd\u003eRango de voltaje de salida\u003c\/td\u003e\n\u003ctd\u003e±5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorriente máxima de salida\u003c\/td\u003e\n\u003ctd\u003e2mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e4e4e4\"\u003e\n\u003ctd\u003eImpedancia de entrada, cada entrada\u003c\/td\u003e\n\u003ctd\u003e100kΩ || 0.01μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltaje aplicado al transductor\u003c\/td\u003e\n\u003ctd\u003e10V nominal, varía con la carga; 25mA, máximo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e4e4e4\"\u003e\n\u003ctd\u003eMedidor digital de panel\u003c\/td\u003e\n\u003ctd\u003e0-1999mV (calibrado en presión mmHg cuando se suministra con manómetro) El medidor muestra valor promedio o ± pico (1-20Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFusible (modelos antiguos)\u003c\/td\u003e\n\u003ctd\u003e120 V: 0.12A, lento, 0.25x1.25” USA\u003cbr\u003e230 V: 0.06A, lento, 0.25x1.25” USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\n\u003ctd\u003eFusible (modelos 2019)\u003c\/td\u003e\n\u003ctd\u003e120 V: 0.12A, lento, 5 x 20 mm métrico\u003cbr\u003e230 V: 0.06A, lento, 5 x 20 mm métrico\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlimentación\u003c\/td\u003e\n\u003ctd\u003e95-135V o 220-240V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#e4e4e4\"\u003e\n\u003ctd\u003eDimensiones\u003c\/td\u003e\n\u003ctd\u003e8.5x5.12x10\" (21.6x13x25.44cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeso para envío\u003c\/td\u003e\n\u003ctd\u003e11 lb. (5kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eF.M. Akgur, G.B. Zibari, J.C. McDonald, D.N. Granger, M.F. Brown\u003c\/strong\u003e \"Cinética de la expresión de P-Selectina en lechos vasculares regionales después de la resucitación por shock hemorrágico: una pista sobre el mecanismo de fallo multiorgánico\" \u003cspan style=\"font-style: italic;\"\u003eShock\u003c\/span\u003e 13. 2000: 140-144\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266241466458,"sku":"SYS-BP1","price":2670.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/bp1_blpr2_fd6f318b-5977-4baf-a1b9-bbb11f9b14ea.jpg?v=1766399597"},{"product_id":"sys-tbm4m-4-channel-transducer-amplifier","title":"Amplificador de Transductor de 4 Canales","description":"\u003c!-- section:details --\u003e\n\u003cp\u003e\u003ca href=\"\/es\/blog\/post\/wpi-s-low-noise-amplifiers-outperform-cheap-imitations\"\u003eVea lo que necesita saber antes de comprar un amplificador\u003c\/a\u003e.\u003c\/p\u003e\r\n\u003ch2\u003eCaracterísticas\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eCompatible con muchos tipos diferentes de transductores basados en resistencia\u003c\/li\u003e\r\n\u003cli\u003eLos transductores de fuerza resistivos WPI se conectan directamente\u003c\/li\u003e\r\n\u003cli\u003eSoporta operación de puente resistivo completo o de un solo extremo\u003c\/li\u003e\r\n\u003cli\u003eControl de compensación de salida\u003c\/li\u003e\r\n\u003cli\u003eCuatro rangos de ganancia de 1 a 1000 ×\u003c\/li\u003e\r\n\u003cli\u003eProporciona voltaje de “excitación” para transductores de puente resistivo\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eBeneficios\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eProporcionado con conectores en blanco para interfaz con cualquier transductor de puente resistivo\u003c\/li\u003e\r\n\u003cli\u003eLos LED de balance de puente proporcionan una señal visual de que los transductores sin carga están en estado de salida cero\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eAplicaciones\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eAmplifica señales de galgas extensiométricas resistivas y otros transductores configurados en puente resistivo\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003eLos transductores pueden conectarse a Transbridge a través de cualquiera de los conectores de 8 pines en el panel frontal. Se proporcionan cuatro enchufes DIN de 8 pines de repuesto con cada instrumento para permitirle recablear cables de transductores de otros fabricantes y conectarlos a Transbridge. Cada canal de Transbridge puede usarse en modo Puente Completo o Medio Puente de forma independiente. Para tipos de transductores distintos a puentes resistivos, como circuitos activos de transistores, dispositivos magnéticos, fotocélulas o piezoeléctricos, los amplificadores diferenciales del instrumento aún pueden usarse eficazmente para amplificación de señal en modos diferencial (puente completo) y de un solo extremo (medio puente).\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/TBM4M_IMs.pdf\" target=\"_self\"\u003eManual de instrucciones TBM4M\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCanales\u003c\/td\u003e\r\n\u003ctd\u003e4\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eAmplificación de voltaje\u003c\/td\u003e\r\n\u003ctd\u003ex1, x10, x100, x1000\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAjuste de compensación de voltaje\u003c\/td\u003e\r\n\u003ctd\u003e±50 mV\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eRuido\u003c\/td\u003e\r\n\u003ctd\u003e.4 µV p-p (0.1 a 10 Hz, G=100)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eLinealidad\u003c\/td\u003e\r\n\u003ctd\u003e± .001% del FSR G=1; ± .01% del FSR, G=1000\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eRango de voltaje de salida\u003c\/td\u003e\r\n\u003ctd\u003e±10 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCorriente máxima de salida\u003c\/td\u003e\r\n\u003ctd\u003e2 mA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eImpedancia de entrada, cada entrada\u003c\/td\u003e\r\n\u003ctd\u003e10\u003csup\u003e10 \u003c\/sup\u003eΩ\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eExcitación del transductor\u003c\/td\u003e\r\n\u003ctd\u003e10VCC (±5 V) aprox.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eAncho de banda, señal pequeña\u003c\/td\u003e\r\n\u003ctd\u003e1 MHz (x1), 80 KHz (x10), 10 KHz (x100), 1.0 KHz (x1000)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFusible (modelos antiguos)\u003c\/td\u003e\r\n\u003ctd\u003e120 V: 0.12A, Lento, 0.25x1.25” USA\u003cbr\u003e230 V: 0.06A, Lento, 0.25x1.25” USA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eFusible (modelos 2019)\u003c\/td\u003e\r\n\u003ctd\u003e120 V: 0.12A, Lento, 5 x 20 mm métrico\u003cbr\u003e230 V: 0.06A, Lento, 5 x 20 mm métrico\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDimensiones\u003c\/td\u003e\r\n\u003ctd\u003e8.5 x 5.12 x 10 in. (21.6 x 13 x 25.44 cm)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003ePeso de envío\u003c\/td\u003e\r\n\u003ctd\u003e11 lb. (5 kg)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266243661914,"sku":"SYS-TBM4M","price":3750.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/sys-tbm4m_d0c473bc-6bdc-4d79-b206-da35149eca6a.jpg?v=1766399678"}],"url":"https:\/\/wpiinc.com\/es\/collections\/call-for-price.oembed?page=2","provider":"World Precision Instruments","version":"1.0","type":"link"}