{"product_id":"al-300-aladdin-single-syringe-pump","title":"Aladdin Einzelspritzenpumpe – nur Infusion","description":"\u003c!-- section:details --\u003e\n\u003ctable cellpadding=\"2\" cellspacing=\"0\" border=\"0\" style=\"border-width: 0px; width: 93.9614%; height: 64px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #0081c2;\"\u003e\n\u003ctd style=\"width: 12.3598%;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eBestellcode\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 26.8264%;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eBeschreibung\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 9.69122%;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003e# Pumpen\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 15.7307%;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eHoher Druck\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.8543%;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eProgrammierbar\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 18.5397%;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eInfusion\/Rückzug\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 12.3598%;\"\u003e\u003cstrong\u003eAL-300\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 26.8264%;\"\u003eEinzelspritzenpumpe\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 9.69122%;\"\u003e 1\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 15.7307%;\"\u003e Nein\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 16.8543%;\"\u003eNein\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 18.5397%;\"\u003eNur Infusion \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEigenschaften\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFasst 1 Spritze, bis zu 60 mL. (140 mL teilweise gefüllt)\u003c\/li\u003e\n\u003cli\u003eInfusionsraten von 0,73 µL\/h (1 mL Spritze) bis 1500 mL\/h (60 mL Spritze)\u003c\/li\u003e\n\u003cli\u003eBenutzerfreundliche Tastatur: Spritzendurchmesser einstellen, Pumpgeschwindigkeit wählen, Start drücken\u003c\/li\u003e\n\u003cli\u003eSpritzen-Spülmodus\u003c\/li\u003e\n\u003cli\u003eStromausfallmodus ermöglicht der Pumpe, nach einem Reset weiter zu pumpen\u003c\/li\u003e\n\u003cli\u003eZeigt das insgesamt abgegebene Volumen in mL oder µL an\u003c\/li\u003e\n\u003cli\u003eInfusionsrate kann während des Pumpens geändert werden\u003c\/li\u003e\n\u003cli\u003eWählbare Einheiten für Infusionsraten: mL\/h, µL\/h, mL\/min, µL\/min\u003c\/li\u003e\n\u003cli\u003ePlatzsparendes Gehäuse: Stellfläche nur 5 3\/4\" x 8 3\/4\"\u003c\/li\u003e\n\u003cli\u003eNimmt keinen unnötigen Platz auf Ihrem Labor- oder Produktionsarbeitsplatz ein\u003c\/li\u003e\n\u003cli\u003eMerkt sich vorherige Einstellungen beim Einschalten\u003c\/li\u003e\n\u003cli\u003ePräzise reproduzierbare Flussraten\u003c\/li\u003e\n\u003cli\u003eBetrieb mit dem mitgelieferten 12VDC-Netzteil. Weltweit verfügbare Netzteile\u003c\/li\u003e\n\u003cli\u003eEinmalspritzen, Glas-, Edelstahl-Spritzen und Zubehör werden separat verkauft (Abgebildete Spritze dient nur zur Demonstration)\u003c\/li\u003e\n\u003cli\u003eWeltweit verfügbare Netzteile\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eNur Infusion!\u003c\/h2\u003e\n\u003cp\u003eZieht nicht zurück, kein Volumenziel, keine Computer-Schnittstelle oder Programmierbarkeit.\u003c\/p\u003e\n\u003ch2\u003eAL-300\u003c\/h2\u003e\n\u003cp\u003eDie AL-300 Einzelspritzenpumpe ist eine reine Infusionspumpe ohne Programmierbarkeit. Sie bietet genau die Funktionen, die Sie möchten, und keine, für die Sie nicht bezahlen wollen. Sie pumpt kontinuierlich, bis Sie die Pumpe stoppen, und Sie können die Infusionsrate während des Pumpens ändern. Sie merkt sich die vorherigen Einstellungen beim Einschalten. Der Stromausfallmodus ermöglicht es der Pumpe, nach einem Reset weiter zu pumpen. Sie verfügt außerdem über einen Spritzen-Spülmodus.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenötigen Sie bidirektionale Infusions-\/Rückzugsfunktionen? Oder eine Mehrfachspritzen-Infusionsanlage? \u003c\/strong\u003e\u003cem\u003eSchauen Sie sich unsere weiteren Produkte aus der Aladdin-Serie an:\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAladdin Einzelspritzen-Infusionspumpe (\u003ca href=\"\/de\/var-2300-aladdin-single-syringe-pump\"\u003eAL-1000\u003c\/a\u003e\u003ca href=\"\/de\/var-2300-aladdin-single-syringe-pump\"\u003e\u003c\/a\u003e)\u003c\/li\u003e\n\u003cli\u003eProgrammierbare Mehrfach-Spritzenpumpe mit 6 Kanälen (\u003ca href=\"\/de\/al-6000-multi-barrel-programmable-6-syringe-pump\"\u003eAL-6000\u003c\/a\u003e)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/AL-300_IMs.pdf\"\u003eAL-300 Manuell\u003c\/a\u003e \u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd\u003e \u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eAL-300\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSPRITZENGRÖSSEN\u003c\/td\u003e\r\n\u003ctd\u003ebis zu 60 mL\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eANZAHL DER SPRITZEN\u003c\/td\u003e\r\n\u003ctd\u003e1 \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMOTORTYP\u003c\/td\u003e\r\n\u003ctd\u003eSchrittmotor, 1\/8 bis 1\/2 Schrittmodi  \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eSCHRITTE PRO UMDREHUNG\u003c\/td\u003e\r\n\u003ctd\u003e 400\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSCHRITTWEISE (max. min.)\u003c\/td\u003e\r\n\u003ctd\u003e0,21 µm bis 0,850 µm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eMOTOR-ZU-ANTRIEBSCHRAUBEN-VERHÄLTNIS\u003c\/td\u003e\r\n\u003ctd\u003e15\/28 \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eGESCHWINDIGKEIT (max.\/min.)\u003c\/td\u003e\r\n\u003ctd\u003e3,7742 cm\/min bis 0,004205 cm\/h \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003ePUMPRATEN\u003c\/td\u003e\r\n\u003ctd\u003e1257 mL\/h mit 60 mL Spritze, bis zu 0,73 µL\/h mit 1 mL Spritze\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMAXIMALE KRAFT\u003c\/td\u003e\r\n\u003ctd\u003e 35 lb. bei minimaler Geschwindigkeit, 18 lb. bei maximaler Geschwindigkeit \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eANZAHL DER PROGRAMMPHASEN\u003c\/td\u003e\r\n\u003ctd\u003ek.A.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRS-232 PUMPENNETZWERK\u003c\/td\u003e\r\n\u003ctd\u003ek.A.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eSTROMVERSORGUNG\u003c\/td\u003e\r\n\u003ctd\u003eWandadapter 12 V DC @ 850 mA \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eABMESSUNGEN\u003c\/td\u003e\r\n\u003ctd\u003e22,9 x 14,6 x 11,4 cm (8,75 x 5,75 x 4,5 in.) \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eGEWICHT\u003c\/td\u003e\r\n\u003ctd\u003e1,6 kg (3,6 lb.) \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eMagnetische Tropfen und Mikrobubbles, die unter Fluss zurückgehalten werden... - Wissenschaftliche Abbildung auf ResearchGate. (o. J.). Abgerufen von \u003ca href=\"https:\/\/www.researchgate.net\/figure\/235402692_fig7_Figure-10-Magnetic-droplets-and-microbubbles-being-retained-under-flow-in-vitro-A\"\u003ehttps:\/\/www.researchgate.net\/figure\/235402692_fig7_Figure-10-Magnetic-droplets-and-microbubbles-being-retained-under-flow-in-vitro-A\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eRouer, M., Meilhac, O., Delbosc, S., Louedec, L., Pavon-Djavid, G., Cross, J., … Alsac, J.-M. (o. J.). Ein neues murines Modell der endovaskulären Aortenaneurysma-Reparatur. \u003ca href=\"http:\/\/doi.org\/10.3791\/50740\"\u003ehttp:\/\/doi.org\/10.3791\/50740\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eZander, N., Gillan, M., \u0026amp; Sweetser, D. (2016). Recycelte PET-Nanofasern für Wasserfiltrationsanwendungen. \u003cem\u003eMaterials\u003c\/em\u003e, \u003cem\u003e9\u003c\/em\u003e(4), 247. \u003ca href=\"http:\/\/doi.org\/10.3390\/ma9040247\"\u003ehttp:\/\/doi.org\/10.3390\/ma9040247\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eKaddumi, E. G. (2016). Der Einfluss von Reizungen des distalen Kolons auf die Veränderungen der Zystometriemesswerte bei Dehnungen von Speiseröhre und Kolon. \u003cem\u003eInt Braz J Urol\u003c\/em\u003e, \u003cem\u003e42\u003c\/em\u003e, 594–602. \u003ca href=\"http:\/\/doi.org\/10.1590\/S1677-5538.IBJU.2015.0238\"\u003ehttp:\/\/doi.org\/10.1590\/S1677-5538.IBJU.2015.0238\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eMcMillan, K. S., Boyd, M., \u0026amp; Zagnoni, M. (2016). Übergang von Mehrphasen- zu Einphasen-Mikrofluidik für Langzeitkultur und Behandlung von mehrzelligen Sphäroiden. \u003cem\u003eLab Chip\u003c\/em\u003e, \u003cem\u003e16\u003c\/em\u003e(18), 3548–3557. \u003ca href=\"http:\/\/doi.org\/10.1039\/C6LC00884D\"\u003ehttp:\/\/doi.org\/10.1039\/C6LC00884D\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eRademeyer, P., Carugo, D., Lee, J. Y., \u0026amp; Stride, E. (2015). Mikrofluidisches System zur Hochdurchsatzcharakterisierung echogener Partikel. \u003cem\u003eLab Chip\u003c\/em\u003e, \u003cem\u003e15\u003c\/em\u003e(2), 417–428. \u003ca href=\"http:\/\/doi.org\/10.1039\/C4LC01206B\"\u003ehttp:\/\/doi.org\/10.1039\/C4LC01206B\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eSandler, N., Kassamakov, I., Ehlers, H., Genina, N., Ylitalo, T., \u0026amp; Haeggstrom, E. (2014). Schnelle interferometrische Abbildung gedruckter, mit Medikamenten beladener Mehrschichtstrukturen. \u003cem\u003eScientific Reports\u003c\/em\u003e, \u003cem\u003e4\u003c\/em\u003e, 4020. \u003ca href=\"http:\/\/doi.org\/10.1038\/srep04020\"\u003ehttp:\/\/doi.org\/10.1038\/srep04020\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eYao, M., Goult, B. T., Chen, H., Cong, P., Sheetz, M. P., Yan, J., … Chen, H. (2014). Mechanische Aktivierung der Vinculin-Bindung an Talin sperrt Talin in einer entfalteten Konformation ein. \u003cem\u003eScientific Reports\u003c\/em\u003e, \u003cem\u003e4\u003c\/em\u003e, 259–88. \u003ca href=\"http:\/\/doi.org\/10.1038\/srep04610\"\u003ehttp:\/\/doi.org\/10.1038\/srep04610\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eZhang, J., Jiang, D., \u0026amp; Peng, H.-X. (2014). Eine druckbeaufschlagte Filtrationstechnik zur Herstellung von Kohlenstoffnanoröhren-Buckypaper: Struktur, mechanische und leitfähige Eigenschaften. \u003cem\u003eMicroporous and Mesoporous Materials\u003c\/em\u003e, \u003cem\u003e184\u003c\/em\u003e, 127–133. \u003ca href=\"http:\/\/doi.org\/10.1016\/j.micromeso.2013.10.012\"\u003ehttp:\/\/doi.org\/10.1016\/j.micromeso.2013.10.012\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eHorst, M., Milleret, V., Nötzli, S., Madduri, S., Sulser, T., Gobet, R., \u0026amp; Eberli, D. (2014). Erhöhte Porosität von elektrogesponnenen Hybridgerüsten verbessert die Blasengewebe-Regeneration. \u003cem\u003eJournal of Biomedical Materials Research. Part A\u003c\/em\u003e, \u003cem\u003e102\u003c\/em\u003e(7), 2116–24. \u003ca href=\"http:\/\/doi.org\/10.1002\/jbm.a.34889\"\u003ehttp:\/\/doi.org\/10.1002\/jbm.a.34889\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eXue, N., Li, X., Bertulli, C., Li, Z., Patharagulpong, A., Sadok, A., … Ridley, A. (2014). Schnelles Musterbilden einer 1-D kollagenen Topographie als ECM-Protein-Fibrillenplattform für die Bildzytometrie. \u003cem\u003ePloS One\u003c\/em\u003e, \u003cem\u003e9\u003c\/em\u003e(4), e93590. \u003ca href=\"http:\/\/doi.org\/10.1371\/journal.pone.0093590\"\u003ehttp:\/\/doi.org\/10.1371\/journal.pone.0093590\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eHosny, N. A., Mohamedi, G., Rademeyer, P., Owen, J., Wu, Y., Tang, M.-X., … Kuimova, M. K. (2013). Kartierung der Mikroblasenviskosität mittels Fluoreszenzlebensdauer-Bildgebung von molekularen Rotoren. \u003cem\u003eProceedings of the National Academy of Sciences\u003c\/em\u003e, \u003cem\u003e110\u003c\/em\u003e(23), 9225–9230. \u003ca href=\"http:\/\/doi.org\/10.1073\/pnas.1301479110\"\u003ehttp:\/\/doi.org\/10.1073\/pnas.1301479110\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eTonurist, K., Thomberg, T., Janes, A., \u0026amp; Lust, E. (2013). Spezifische Leistung von elektrischen Doppelschichtkondensatoren basierend auf verschiedenen Separator-Materialien und nicht-wässrigen Elektrolyten. \u003cem\u003eECS Transactions\u003c\/em\u003e, \u003cem\u003e50\u003c\/em\u003e(43), 181–189. \u003ca href=\"http:\/\/doi.org\/10.1149\/05043.0181ecst\"\u003ehttp:\/\/doi.org\/10.1149\/05043.0181ecst\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eBahnemann, J., Rajabi, N., Fuge, G., Barradas, O., Müller, J., Pörtner, R., \u0026amp; Zeng, A.-P. (2013). Ein neues integriertes Lab-on-a-Chip-System für schnelle dynamische Studien an Säugerzellen unter physiologischen Bedingungen im Bioreaktor. \u003cem\u003eCells\u003c\/em\u003e, \u003cem\u003e2\u003c\/em\u003e(2), 349–360. \u003ca href=\"http:\/\/doi.org\/10.3390\/cells2020349\"\u003ehttp:\/\/doi.org\/10.3390\/cells2020349\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eZhang, J., Jiang, D., Peng, H.-X., \u0026amp; Qin, F. (2013). Verbesserte mechanische und elektrische Eigenschaften von Kohlenstoffnanoröhren-Buckypaper durch in situ Vernetzung. \u003cem\u003eCarbon\u003c\/em\u003e, \u003cem\u003e63\u003c\/em\u003e, 125–132. \u003ca href=\"http:\/\/doi.org\/10.1016\/j.carbon.2013.06.047\"\u003ehttp:\/\/doi.org\/10.1016\/j.carbon.2013.06.047\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eYin, B., Kuranov, R. V., McElroy, A. B., Kazmi, S., Dunn, A. K., Duong, T. Q., \u0026amp; Milner, T. E. (2013). Dualwellenlängen photothermische optische Kohärenztomographie zur Bildgebung der Sauerstoffsättigung im Mikrovaskulaturblut. \u003cem\u003eJournal of Biomedical Optics\u003c\/em\u003e, \u003cem\u003e18\u003c\/em\u003e(5), 56005. \u003ca href=\"http:\/\/doi.org\/10.1117\/1.JBO.18.5.056005\"\u003ehttp:\/\/doi.org\/10.1117\/1.JBO.18.5.056005\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eTonurist, K., Thomberg, T., Janes, A., Romann, T., Sammelselg, V., \u0026amp; Lust, E. (2013). Polymorphes Verhalten und Morphologie elektrogesponnener Poly(Vinylidenfluorid)-Separator-Materialien für nicht-wässrige Elektrolyt-basierte elektrische Doppelschichtkondensatoren. \u003cem\u003eECS Transactions\u003c\/em\u003e, \u003cem\u003e50\u003c\/em\u003e(45), 49–58. \u003ca href=\"http:\/\/doi.org\/10.1149\/05045.0049ecst\"\u003ehttp:\/\/doi.org\/10.1149\/05045.0049ecst\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eZander, N. E., Orlicki, J. A., Rawlett, A. M., \u0026amp; Beebe, T. P. (2013). Elektrogesponnene Polycaprolacton-Gerüste mit angepasster Porosität durch zwei Ansätze für verbesserte zelluläre Infiltration. \u003cem\u003eJournal of Materials Science. Materials in Medicine\u003c\/em\u003e, \u003cem\u003e24\u003c\/em\u003e(1), 179–87. \u003ca href=\"http:\/\/doi.org\/10.1007\/s10856-012-4771-7\"\u003ehttp:\/\/doi.org\/10.1007\/s10856-012-4771-7\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eHerricks, T., Avril, M., Janes, J., Smith, J. D., \u0026amp; Rathod, P. K. (2013). Klonale Varianten von Plasmodium falciparum zeigen unter dynamischen Flussbedingungen eine enge Bandbreite an Rollgeschwindigkeiten zum Wirtsrezeptor CD36. \u003cem\u003eEukaryotic Cell\u003c\/em\u003e, \u003cem\u003e12\u003c\/em\u003e(11), 1490–8. \u003ca href=\"http:\/\/doi.org\/10.1128\/EC.00148-13\"\u003ehttp:\/\/doi.org\/10.1128\/EC.00148-13\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eFerreira, D. S., Reis, R. L., \u0026amp; Azevedo, H. S. (2013). Peptidbasierte Mikrokapseln, hergestellt durch Selbstassemblierung und Mikrofluidik, als kontrollierte Umgebungen für Zellkulturen. \u003cem\u003eSoft Matter\u003c\/em\u003e, \u003cem\u003e9\u003c\/em\u003e(38), 9237. \u003ca href=\"http:\/\/doi.org\/10.1039\/c3sm51189h\"\u003ehttp:\/\/doi.org\/10.1039\/c3sm51189h\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eBirngruber, T., Ghosh, A., Perez-Yarza, V., Kroath, T., Ratzer, M., Pieber, T. R., \u0026amp; Sinner, F. (2013). Cerebrale offene Flussmikroperfusion: eine neue in vivo Technik zur kontinuierlichen Messung des Stofftransports über die intakte Blut-Hirn-Schranke. \u003cem\u003eClinical and Experimental Pharmacology \u0026amp; Physiology\u003c\/em\u003e, \u003cem\u003e40\u003c\/em\u003e(12), 864–71. \u003ca href=\"http:\/\/doi.org\/10.1111\/1440-1681.12174\"\u003ehttp:\/\/doi.org\/10.1111\/1440-1681.12174\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eLuboz, V., Promayon, E., Chagnon, G., Alonso, T., Favier, D., Barthod, C., \u0026amp; Payan, Y. (2012). Validierung eines leichten Absauggeräts zur in vivo Weichgewebecharakterisierung (LASTIC) Validierung eines leichten Absauggeräts für in vivo. \u003cem\u003eWeichgewebecharakterisierung\u003c\/em\u003e, \u003cem\u003e8415\u003c\/em\u003e, 243–256.\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eOwen, J., Zhou, B., Rademeyer, P., Tang, M.-X., Pankhurst, Q., Eckersley, R., \u0026amp; Stride, E. (2012). Verständnis der Struktur und des Bildungsmechanismus einer neuen magnetischen Mikroschaum-Formulierung. \u003cem\u003eTheranostics\u003c\/em\u003e, \u003cem\u003e2\u003c\/em\u003e(12), 1127–1139. \u003ca href=\"http:\/\/doi.org\/10.7150\/thno.4307\"\u003ehttp:\/\/doi.org\/10.7150\/thno.4307\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp style=\"margin-left: 24pt; text-indent: -24.0pt;\"\u003eDesai, P. (2006). Vergleich von Wurzelkanalspülsystemen zur Reduktion intrakanaler Mikroorganismen unter Verwendung von Kochsalzlösung – eine In-vitro-Studie.\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266076807258,"sku":"AL-300","price":380.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/AL-300.png?v=1773775068","url":"https:\/\/wpiinc.com\/de\/products\/al-300-aladdin-single-syringe-pump","provider":"World Precision Instruments","version":"1.0","type":"link"}