{"title":"Optische Detektoren","description":"\u003ch1\u003eOptische Detektoren\u003c\/h1\u003e\n\u003cstyle\u003e#html-body [data-pb-style=D7BPKQF]{justify-content:flex-start;display:flex;flex-direction:column;background-position:left top;background-size:cover;background-repeat:no-repeat;background-attachment:scroll}\u003c\/style\u003e\n\u003cdiv data-element=\"main\" data-appearance=\"contained\" data-content-type=\"row\"\u003e\n\u003cdiv data-pb-style=\"D7BPKQF\" data-element=\"inner\" data-video-fallback-src=\"\" data-video-lazy-load=\"true\" data-video-play-only-visible=\"true\" data-video-loop=\"true\" data-background-type=\"image\" data-background-images=\"{}\" data-parallax-speed=\"0.5\" data-enable-parallax=\"0\"\u003e\n\u003cdiv data-element=\"main\" data-appearance=\"default\" data-content-type=\"text\"\u003e\n\u003cp\u003eUnsere Sauerstoffdetektionssysteme sowie Sonden, Glasfaserkabel, Kollimatoren und Spektroskopiezubehör finden Sie auf dieser Seite. Das OXY-MINI Sauerstoffdetektionssystem ist für Prozesssteuerungs- und Biotechnologieanwendungen optimiert. Das OXY-MICRO System ist für biologische Forschungsanwendungen konzipiert, einschließlich Implantation in Gewebe, Zellkulturen, Profilierung von Biofilmen und sedimentbezogenen Bioassays. Das Messprinzip des Sensorsystems basiert auf der Erfassung der Sauerstoffkonzentration als Funktion der Lumineszenzlebensdauer, entweder in gelöster oder gasförmiger Phase.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","products":[{"product_id":"13370-sma-half-length-bulkhead-feedthru-connector-coupler","title":"SMA Halblängen-Durchführungsstecker\/Kupplung","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eEigenschaften\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"page-title\"\u003e\u003cspan class=\"base\" data-ui-id=\"page-title-wrapper\"\u003eSMA-terminiert\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"page-title\"\u003eHalblänge\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"page-title\"\u003eDurchführung für Trennwände\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"page-title\"\u003eGlasfaserstecker (Kuppler)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42262684434522,"sku":"13370","price":25.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/13370_c90233fc-1302-4cad-8251-4b4f52d479a8.jpg?v=1766392796"},{"product_id":"13395-sma-bulkhead-feedthru-connector-coupler","title":"SMA Durchführungsstecker\/Kupplung","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eEigenschaften\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"page-title\"\u003e\u003cspan class=\"base\" data-ui-id=\"page-title-wrapper\"\u003eSMA-terminiert\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"page-title\"\u003eDurchführung für Trennwandmontage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"page-title\"\u003eGlasfaserstecker (Kuppler)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42262687842394,"sku":"13395","price":25.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/13395_8973e149-9ace-4dd1-a2f9-3689973b5feb.jpg?v=1766392812"},{"product_id":"42200-universal-dipping-probe-stand","title":"UNIVERSAL TAUCHSONDENHALTER","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eEigenschaften\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eHält DipTips, DipTip Minis, SpectroPipetter und Biosensoren (Makro und Mikro)\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDas Set enthält:\u003c\/h2\u003e\r\n\u003cp\u003e(1) \u003cstrong\u003e\u003ca href=\"\/de\/503084-frameworks-small-v-base\"\u003e503084\u003c\/a\u003e\u003c\/strong\u003e Kleine V-Basis\u003cbr\u003e(1) \u003cstrong\u003e\u003ca href=\"\/de\/503073-frameworks-polished-stainless-steel-post-25cm-m8\"\u003e503073\u003c\/a\u003e\u003c\/strong\u003e 25 cm Edelstahlpfosten \u003cbr\u003e(1) Halterung, Delrin mit Daumenschraube\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/42200_IS.pdf\" target=\"_blank\"\u003e\u003cstrong\u003eUniversalhalter für Tauchsonden - Anleitung\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42262700327002,"sku":"42200","price":275.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/universal_dippin_4dd66f90511ca_616d8840-840d-42ab-a5fc-f10578a825f6.jpg?v=1766393059"},{"product_id":"56200-inline-fiber-optic-filter-holder-sma","title":"Inline-Faseroptischer Filterhalter (SMA)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eEigenschaften\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eInline-Filter für SMA-terminierte Fasern\u003c\/li\u003e\r\n\u003cli\u003eKollimatoren für UV\/VIS\/NIR\u003c\/li\u003e\r\n\u003cli\u003eFilterdurchmesser 12,5–25,4 mm\u003c\/li\u003e\r\n\u003cli\u003eFilterdicke 2–10 mm\u003c\/li\u003e\r\n\u003cli\u003eErmöglicht das Einsetzen von optischen Filtern innerhalb eines faseroptischen Pfads\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eVorteile\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eKein Streulicht\u003c\/li\u003e\r\n\u003cli\u003eRobustes Design\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eAnwendungen\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eStreulichtfilterung\u003c\/li\u003e\r\n\u003cli\u003eEntfernung von Anregungslicht bei der Fluoreszenzdetektion\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003eFilter mit Außendurchmessern von 8 bis 25,4 mm und Dicken von 2 bis 10 mm können aufgenommen werden. Das Design begrenzt die seitliche und axiale Bewegung des Filters, wenn er im Halter gesichert ist.\u003cbr\u003eZwei faseroptische Kollimatoren sind intern im Halter montiert, um kollimiertes Licht durch den Filter zu leiten und anschließend das gefilterte Licht in die Öffnung der Ausgangsfaser zu fokussieren. Der Spektralbereich wird weitgehend durch die Bandbreite der Glasfasern begrenzt (von UV bis nahes IR mit WPI UV-verbesserten Kabeln).\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/56200-im-071201.pdf\"\u003e56200 Bedienungsanleitung\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42265630081114,"sku":"56200","price":895.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/56200_941e1b11-bc07-4405-811f-a7a293bb2374.jpg?v=1766393085"},{"product_id":"501641-minitip-fiber-optic-oxygen-sensor","title":"MiniTip - Faseroptischer Sauerstoffsensor","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eEigenschaften\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSpitzendurchmesser: 4 mm\u003c\/li\u003e\n\u003cli\u003ePolymer-Glasfaser mit sauerstoffempfindlicher Beschichtung\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:details --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42265726484570,"sku":"501641","price":699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/oxy-mini-aot-minitip_e52b3802-8e80-4dc0-8372-401f06e2ab5c.jpg?v=1766393851"},{"product_id":"501642-miniflow-flow-through-cell-with-integrated-planar-oxygen-senso","title":"MiniFlow - Durchflusszelle mit integriertem planarem Sauerstoffsensor","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eEigenschaften\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDurchflusszelle\u003c\/li\u003e\n\u003cli\u003eIntegrierter Sauerstoffsensor\u003c\/li\u003e\n\u003cli\u003eT-förmig\u003c\/li\u003e\n\u003cli\u003eLuer-Lock-Anschlüsse\u003c\/li\u003e\n\u003cli\u003eAnsprechzeit: 40 s\u003c\/li\u003e\n\u003cli\u003eAusgezeichnete Langzeitstabilität\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:details --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42265727041626,"sku":"501642","price":699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/oxy-mini-aot-miniflow_49b09a19-9380-4058-8664-738d66f2202f.jpg?v=1766393858"},{"product_id":"var-797-microtip-fiber-optic-oxygen-sensor","title":"MicroTip - Faseroptischer Sauerstoffsensor","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eEigenschaften\u003c\/h2\u003e\u003cul\u003e\r\n\u003cli\u003eNadelartiges Gehäuse\u003c\/li\u003e\r\n\u003cli\u003e2,5 m Kabel\u003c\/li\u003e\r\n\u003cli\u003e0-250 % Luftsättigung\u003c\/li\u003e\r\n\u003cli\u003e20 mm Nadel mit 27 Gauge (0,400 mm) Durchmesser\u003c\/li\u003e\r\n\u003cli\u003e50 µm Spitze\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptionen\u003c\/h2\u003e\r\n\u003ctable\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eBestellcode\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd style=\"text-align: left;\"\u003e501656\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left;\"\u003eMicroTip, nadelartiger faseroptischer Sauerstoffsensor, 50 μm Spitze\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left;\"\u003e501656-C\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left;\"\u003eMicroTip, nadelartiges Gehäuse, 50 μm Spitze, optische Isolation\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #ffffff;\"\u003e\r\n\u003ctd style=\"text-align: left;\"\u003e501656-F\u003c\/td\u003e\r\n\u003ctd\u003eMicroTip, nadelartiges Gehäuse, 140 μm flache Spitze\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e\u003cstrong\u003eDetails anzeigen\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDer MicroTip ist ein nadelartiger (27 Gauge) Sauerstoff-Mikrosensor, der für Anwendungen entwickelt wurde, bei denen eine kleine Spitzengröße von 50 µm und eine schnelle Ansprechzeit (t90) von 1 s erforderlich sind. Die sauerstoffempfindliche Sensorspitze besteht aus 140 µm Faser, die auf eine 50 µm Spitze verjüngt ist. Der Sensor ist in einer Edelstahlnadel mit 22 mm Länge und 0,4 mm Durchmesser untergebracht. Dies ermöglicht das Eindringen durch ein Septumgummi oder ähnliches Material. Diese Sensoren sind ideal für Sauerstoffprofile in Sedimenten und Biofilmen.\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e \u003cstrong\u003e501656-C\u003c\/strong\u003e - Dieser Sensor ist für optische Isolation beschichtet. Die optische Isolation ist ein optionales, undurchsichtiges, sauerstoffdurchlässiges Material, das über den Luminophor aufgetragen werden kann, um zu verhindern, dass Umgebungslicht den Sensor erreicht, und auch zu verhindern, dass Anregungslicht entweicht. Diese Beschichtung verlängert die Reaktionszeit aufgrund der zusätzlichen Materialsicht, durch die Sauerstoff diffundieren muss, um den Luminophor zu erreichen.\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cstrong\u003e501656-F \u003c\/strong\u003e- Dieser Sensor hat eine 140 μm flache Spitze.\u003c\/li\u003e\r\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e","brand":"World Precision Instruments","offers":[{"title":"50 µm Spitze | faseroptischer Sauerstoffsensor","offer_id":42265729826906,"sku":"501656","price":414.0,"currency_code":"USD","in_stock":true},{"title":"50 µm Spitze | optische Isolation","offer_id":42265729859674,"sku":"501656-C","price":415.0,"currency_code":"USD","in_stock":true},{"title":"140 µm flache Spitze","offer_id":42265729892442,"sku":"501656-F","price":325.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microtip___fiber_4ede62f1283ad_26e04fc2-33fe-4283-91e8-e5ca3ff73682.jpg?v=1766393888"},{"product_id":"var-2320-bifurcated-fiber-optic-assemblies","title":"Gabelartige Lichtwellenleiter-Baugruppen","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eBifurkierte Lichtwellenleiter-Baugruppen\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eLicht in zwei Fasern kombinieren oder aufteilen\u003c\/li\u003e\r\n\u003cli\u003eFasern mit unterschiedlichen Durchmessern ermöglichen verschiedene Leistungsverhältnisse\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptionen\u003c\/h2\u003e\r\n\u003ctable style=\"height: 110px; width: 525px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eBestellcode\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eFaseroptisch\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd\u003eBIF22\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left;\"\u003eÄhnliche Intensitäten teilen oder kombinieren (200\/200)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: center;\"\u003eBIF44\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left;\"\u003eÄhnliche Intensitäten teilen oder kombinieren (400\/400)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd style=\"text-align: center;\"\u003eBIF62\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left;\"\u003eUV (600) + VIS (200) kombinieren\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: center;\"\u003eBIF66\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left;\"\u003eÄhnliche Intensitäten teilen oder kombinieren (600\/600)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e  \u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eVorteile\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eVerschiedene bifurkierte Fasern für kundenspezifische Anwendungen\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cstrong\u003eAnwendungen\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eReferenzmessung in Dual-Kanal-Spektrometern\u003c\/li\u003e\r\n\u003cli\u003eUV- und VIS-Lichtquellen kombinieren\u003c\/li\u003e\r\n\u003cli\u003eLicht in zwei Probenzellen einkoppeln\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003ch2\u003eVideo\u003c\/h2\u003e\r\n\r\n\u003cp\u003eWPI Photonik-Kompetenzzentrum Array optischer Produkte\u003c\/p\u003e\r\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/YjXWnOc2faM?rel=0\" width=\"747\" height=\"420\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003eWPI Optische Fasern Lösungen für Forscher und Produktentwickler\u003c\/p\u003e\r\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/pesp2ugr4Bc?rel=0\" width=\"747\" height=\"420\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eLänge\u003c\/td\u003e\r\n\u003ctd\u003e1 Meter\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eAnschlüsse\u003c\/td\u003e\r\n\u003ctd\u003eSMA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eWellenlängenbereiche\u003c\/td\u003e\r\n\u003ctd\u003e200-1100 nm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd\u003eKabeltyp\u003c\/td\u003e\r\n\u003ctd\u003eUV-verbessert\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"200\/200","offer_id":42266086146138,"sku":"BIF22","price":627.0,"currency_code":"USD","in_stock":true},{"title":"400\/400","offer_id":42266086178906,"sku":"BIF44","price":675.0,"currency_code":"USD","in_stock":true},{"title":"UV (600) VIS (200)","offer_id":42266086211674,"sku":"BIF62","price":822.0,"currency_code":"USD","in_stock":true},{"title":"600\/600","offer_id":42266086244442,"sku":"BIF66","price":775.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/fo-splitter_82832ddc-6dc6-4ec7-8331-1d83f6870bfd.jpg?v=1766396887"},{"product_id":"fo-600as-sma-anti-solarization-fiber-optic-cables","title":"Anti-Solarisation Glasfaserkabel, 600 µm Kern","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eEigenschaften\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eLichtwellenleiterkabel, 1 m, SMA, 600 µm Kern, Anti-Solarisation\u003c\/li\u003e\r\n\u003cli\u003eUniversal-UV-VIS-Faser \u003c\/li\u003e\r\n\u003cli\u003eSolarisationsresistente Faser\u003c\/li\u003e\r\n\u003cli\u003eSiliziumdioxid-Multimode-Faser, speziell für die Übertragung von UV-Licht entwickelt\u003c\/li\u003e\r\n\u003cli\u003eÜberträgt Licht im sichtbaren Bereich (200 nm–1200 nm)\u003c\/li\u003e\r\n\u003cli\u003eMit SMA-Steckverbindern ausgestattet\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eVorteile\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eFasern stabilisieren sich auf weniger als 5 % Verschlechterung über einen Zeitraum von 20.000 Stunden nach einem anfänglichen Übertragungsverlust („Burn-in“) von weniger als 25 %\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eAnwendungen\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDeep-UV-Spektroskopie\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eAnti-Solarisation\u003c\/h2\u003e\r\n\u003cp\u003eDie Transmission von herkömmlichen UV-verbesserten Siliziumdioxid\/Siliziumdioxid-Fasern nimmt bei Wellenlängen unter 240 nm bei hoher Intensität einer Deuteriumlampe schnell ab. Dieser Effekt wird als „UV-Solarisation“ bezeichnet und entsteht durch die Bildung von Farbzentren im Fasermaterial. Die Lebensdauer einer solchen Faser, definiert durch die 1\/e-Reduktion der Transmission bei 240 nm, beträgt normalerweise weniger als 200 Minuten. Dieser Effekt macht sie für die UV-Spektroskopie unter 240 nm ungeeignet.\u003c\/p\u003e\r\n\u003cp\u003eAnti-Solarisationsfasern, geeignet für Deep-UV-Spektroskopie, lösen dieses Problem. Diese Fasern stabilisieren sich auf weniger als 5 % Verschlechterung über einen Zeitraum von 20.000 Stunden nach einem anfänglichen Übertragungsverlust („Burn-in“) von weniger als 25 %. Zusätzlich verschlechtert sich diese Anti-Solarisationseigenschaft im Laufe der Zeit nicht.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eEigenschaften\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cdiv\u003e• Multimode • Reiner Siliziumdioxidkern • Numerische Apertur: 0,22 ± 0,02 (Standard) • Standard-Druckprüfung: 70 kpsi • Minimaler Biegeradius: 100x Mantelradius (momentan), 600x Mantelradius (langfristig)\u003c\/div\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable style=\"height: 177px; width: 368px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center;\" colspan=\"2\"\u003e\u003cspan style=\"color: #ffffff;\"\u003eSpezifikationen\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMODUS\u003c\/td\u003e\r\n\u003ctd\u003eMultimode\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eKERN\u003c\/td\u003e\r\n\u003ctd\u003eReines Siliziumdioxid\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eNumerische Apertur\u003c\/td\u003e\r\n\u003ctd\u003e0,22 ± 0,02 (Standard)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eStandard-Druckprüfung\u003c\/td\u003e\r\n\u003ctd\u003e70 kpsi\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"2\"\u003eMinimaler Biegeradius\u003c\/td\u003e\r\n\u003ctd\u003e100x Mantelradius (momentan)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e600x Mantelradius (langfristig)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266149159002,"sku":"FO-600AS-SMA","price":375.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/fo-cable_d6eaf4c0-ef7c-4df0-a7ed-e5e473bf5b66.jpg?v=1766397957"},{"product_id":"fo-100-sma1m-uv-enhanced-fiber-optic-cables","title":"UV-verbesserte Glasfaserkabel-FO-100-SMA1M","description":"\u003c!-- section:details --\u003e\n\u003cul\u003e\n\u003cli\u003eUV-verbessertes Glasfaserkabel\u003c\/li\u003e\n\u003cli\u003e10 µm, 1 m Länge, SMA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266150043738,"sku":"FO-100-SMA1M","price":118.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/fiber_optic_cabl_4f4e59390cb0d_6fdf796d-be68-43f2-900e-08d41fdfaff6.jpg?v=1766397964"},{"product_id":"iso-oxy-2-iso-oxy-2-oxygen-sensor-2mm","title":"ISO-OXY-2 Sauerstoffsensor - 2 mm","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eEigenschaften\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGasdurchlässige Polymermembranhülse blockiert Flüssigkeiten, Ionen und Partikel\u003c\/li\u003e\n\u003cli\u003eIntegrierte Referenzelektrode\u003c\/li\u003e\n\u003cli\u003eZur Verwendung mit \u003cstrong\u003eApollo1000\u003c\/strong\u003e, \u003cstrong\u003eApollo4000\u003c\/strong\u003e, \u003ca href=\"\/de\/tbr4100-four-channel-free-radical-analyzer\"\u003e\u003cstrong\u003eTBR4100\u003c\/strong\u003e\u003c\/a\u003e und \u003ca href=\"\/de\/tbr1025-one-channel-free-radical-analyzer\"\u003e\u003cstrong\u003eTBR1025\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eAnsprechzeit: \u0026lt; 10s\u003c\/li\u003e\n\u003cli\u003eNachweisgrenze: 0,1 % bis 100 %\u003c\/li\u003e\n\u003cli\u003eDrift: \u0026lt;1 %\/min\u003c\/li\u003e\n\u003cli\u003eVerpackungseinheit: 1 Stück\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eVorteile\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eClark-Typ Sauerstoffsensor mit einer Spitzenbreite von 2 mm, geeignet für Messungen von sehr kleinen O\u003csub\u003e2\u003c\/sub\u003e-Volumina\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAnwendungen\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eZellkulturen, Zellaufschlämmungen\u003c\/li\u003e\n\u003cli\u003eZellgewebemessungen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDer \u003cstrong\u003eISO-OXY-2\u003c\/strong\u003e ist ein 2,0 mm großer Sensor aus Edelstahl mit austauschbaren Membranhülsen (5378) und einem internen nachfüllbaren Elektrolyten (#\u003ca href=\"\/de\/7326-sys-iso2-filling-solution\"\u003e7326\u003c\/a\u003e).\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/2mmkit_97e1079d-0e4d-42f1-982b-48ca3a6d8731.jpg?v=1765946747\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/2mmkit_97e1079d-0e4d-42f1-982b-48ca3a6d8731.jpg?v=1765946747\" alt=\"2mm Biosensoren werden mit Ersatzteilen geliefert\" width=\"377\" height=\"212\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHINWEIS\u003c\/strong\u003e: Die 2mm Biosensoren werden mit zwei Ersatz-Membranhülsen, einer 1-cc-Spritze, einer MF28G67 MicroFil-Nadel und 10 ml Fülllösung (#\u003ca href=\"\/de\/7326-sys-iso2-filling-solution\"\u003e7326\u003c\/a\u003e) geliefert.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ISO-OXY-2-performance_1ef41956-359e-4071-ae50-1c8a07900f28.jpg?v=1765946753\" alt=\"ISO-OXY-2 Leistungsergebnisse\"\u003e\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ISO-OXY-2_IMs.pdf\" target=\"_self\"\u003e\u003cstrong\u003eISO-OXY-2 Bedienungsanleitung\u003c\/strong\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/Xy_vTV1v-Z0\" width=\"600\" height=\"450\" frameborder=\"0\" data-mce-fragment=\"1\"\u003e\u003c\/iframe\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eANWENDUNG\u003c\/td\u003e\n\u003ctd\u003eZellkulturen, Zellaufschlämmungen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eSENSOR DURCHMESSER\u003c\/td\u003e\n\u003ctd\u003e2,0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eANSPRECHZEIT\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 SEK (90 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eNACHWEISGRENZE\u003c\/td\u003e\n\u003ctd\u003e0,1 % bis 100 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDRIFT\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1 %\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003eEMPFINDLICHKEIT\u003c\/td\u003e\n\u003ctd\u003ek.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePHYSIOLOGISCHE STÖRUNGEN\u003c\/td\u003e\n\u003ctd\u003eKeine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eX. Liu, C. Cheng, N. Zorko, S. Cronin, Y.R. Chen, J.L. Zweier\u003c\/strong\u003e „Biphasische Modulation des vaskulären Stickstoffmonoxid-Katabolismus durch Sauerstoff“ \u003cspan style=\"font-style: italic;\"\u003eAm J Phhsiol Heart circ Physiol\u003c\/span\u003e 287. 2004: H2421-H2426\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOlson, K. R., Gao, Y., DeLeon, E. R., Arif, M., Arif, F., Arora, N., \u0026amp; Straub, K. D. (2017).\u003c\/b\u003e Katalase als Sulfid-Schwefel-Oxidoreduktase: Ein alter (und moderner?) Regulator reaktiver Schwefel-Spezies (RSS). \u003ci\u003eRedox Biology\u003c\/i\u003e, \u003ci\u003e12\u003c\/i\u003e, 325–339. \u003ca href=\"https:\/\/doi.org\/10.1016\/j.redox.2017.02.021\"\u003ehttps:\/\/doi.org\/10.1016\/j.redox.2017.02.021\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHirai, T., Osamura, T., Ishii, M., \u0026amp; Arai, H. (2016).\u003c\/b\u003e Expression mehrerer cbb3 Cytochrom-c-Oxidase-Isoformen durch Kombinationen mehrerer Iso-Untereinheiten in Pseudomonas aeruginosa. \u003ci\u003eProceedings of the National Academy of Sciences of the United States of America\u003c\/i\u003e, \u003ci\u003e113\u003c\/i\u003e(45), 12815–12819. \u003ca href=\"https:\/\/doi.org\/10.1073\/pnas.1613308113\"\u003ehttps:\/\/doi.org\/10.1073\/pnas.1613308113\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePark, Y. M., Lee, H. J., Jeong, J.-H., Kook, J.-K., Choy, H. E., Hahn, T.-W., \u0026amp; Bang, I. S. (2015).\u003c\/b\u003e Verzweigtkettige Aminosäure-Supplementierung fördert das aerobe Wachstum von Salmonella Typhimurium unter nitrosativem Stress. \u003ci\u003eArchives of Microbiology\u003c\/i\u003e, \u003ci\u003e197\u003c\/i\u003e(10), 1117–1127. \u003ca href=\"https:\/\/doi.org\/10.1007\/s00203-015-1151-y\"\u003ehttps:\/\/doi.org\/10.1007\/s00203-015-1151-y\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266182713434,"sku":"ISO-OXY-2","price":1092.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/iso-oxy-2_1_9cfae048-4e15-49e1-88de-03c55c9d8a8e.jpg?v=1766398349"},{"product_id":"oxy-micro-aot-fiber-optic-oxygen-meter-for-microsensors","title":"Faseroptisches Sauerstoffmessgerät für Mikrosensoren","description":"\u003c!-- section:details --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/OxyMicro.pdf\"\u003eHier klicken, um das aktuelle \u003cstrong\u003eDatenblatt\u003c\/strong\u003e anzusehen\u003c\/a\u003e.\u003c\/p\u003e\r\n\u003ch2\u003eEigenschaften\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eSauerstoff wird während des Experiments nicht verbraucht\u003c\/li\u003e\r\n\u003cli\u003eUnempfindlich gegenüber elektrischen und magnetischen Störungen\u003c\/li\u003e\r\n\u003cli\u003eAusgezeichnete Langzeitstabilität\u003c\/li\u003e\r\n\u003cli\u003eKeine langwierige Polarisation notwendig (wie bei Clark-Typ O2-Elektroden)\u003c\/li\u003e\r\n\u003cli\u003eSchnelle Ansprechzeit \u0026lt; 0,5 s für MicroTip-Sensoren\u003c\/li\u003e\r\n\u003cli\u003eSondenabmessung der MicroTip-Sensoren bis zu 50 µm klein\u003c\/li\u003e\r\n\u003cli\u003eMessung ist in trockenem Gas möglich\u003c\/li\u003e\r\n\u003cli\u003eOptische Isolierung der Sensorspitze verfügbar für fluoreszierende oder photosynthetisch aktive Proben\u003c\/li\u003e\r\n\u003cli\u003eDie Sensoren sind nicht im System enthalten\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eVorteile\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eUnbeeinflusst von Lichtquellenstabilität und Intensitätsschwankungen, da es auf Lumineszenz-Lebensdauer-Messungen basiert.\u003c\/li\u003e\r\n\u003cli\u003eKompakte, tragbare Messgeräte können innen oder außen verwendet werden\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eAnwendungen\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eProzesskontrolle wie Abfüllanlagen in Brauereien und Qualitätskontrolle von Verpackungen (OxyMini)\u003c\/li\u003e\r\n\u003cli\u003eBiotechnologie wie Kontrolle von Zellkulturmedien und nicht-invasive Kontrolle von Bioreaktoren (OxyMini)\u003c\/li\u003e\r\n\u003cli\u003eImplantation von Sauerstoffsensoren in Boden und Bäume (OxyMini)\u003c\/li\u003e\r\n\u003cli\u003eSauerstoffprofile von marinem Sediment, Böden oder Gewebe (OxyMicro)\u003c\/li\u003e\r\n\u003cli\u003eImplantation in lebendes Gewebe wie Herz- oder Muskelgewebe (OxyMicro)\u003c\/li\u003e\r\n\u003cli\u003eKontrolle von Zellkulturmedien in der Biotechnologie (OxyMicro)\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eUnbeeinflusst von Lichtquellenstabilität und Intensität\u003c\/h2\u003e\r\n\u003cp\u003eKonventionelle faseroptische Sauerstoffsensor-Systeme, die auf Intensitätsmessungen basieren, sind in ihrer Genauigkeit durch die Stabilität der Lichtquelle und Schwankungen des Umgebungslichts begrenzt. Durch die Verwendung einer Lumineszenz-Lebensdauer-Messung werden Messungen nicht durch die Stabilität der Lichtquelle, Intensitätsschwankungen durch Faserbiegung oder Änderungen der optischen Eigenschaften der Probe (Trübung, Brechungsindex, Färbung usw.) beeinflusst.\u003c\/p\u003e\r\n\u003cp\u003eKalibrierung: Die Sensoren können durch eine einfache Zweipunktkalibrierung kalibriert werden, 100% Luftsättigung und 0% Luftsättigung.\u003c\/p\u003e\r\n\u003ch2\u003eKompakte, tragbare Messgeräte für Innen- und Außenbereich\u003c\/h2\u003e\r\n\u003cp\u003eDie OxiMini und OxyMicro faseroptischen Sauerstoffmessgeräte sind kompakt und leicht zu transportieren. Für den Innen- und Außeneinsatz konzipiert, können sie über eine RS232-Schnittstelle an einen PC angeschlossen werden. Daten können mit der mitgelieferten Software visualisiert, analysiert und gespeichert werden. Eine vollständige Palette von Sensoren ist verfügbar.\u003c\/p\u003e\r\n\u003ch2\u003eOxyMicro Systeme\u003c\/h2\u003e\r\n\u003cp\u003eOxyMicro ist ein Einkanal-O2-Messgerät für faseroptische O2-Mikrosensoren.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eMicroTip\u003c\/strong\u003e – \u003cimg style=\"float: right;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/oxyMicroTip_sml_e37ddfcb-60da-4838-a51b-4f9d5d17d42e.jpg?v=1765947313\" alt=\"\" align=\"right\"\u003eDer MicroTip (501656) ist ein nadelartiger (27 ga.) Sauerstoff-Mikrosensor, der für Anwendungen entwickelt wurde, bei denen eine kleine Spitzenbreite (50 µm) und eine schnelle Ansprechzeit (t90) von 1 Sekunde erforderlich sind. Die sauerstoffempfindliche Sensorspitze besteht aus einer 140 µm Faser, die auf eine 50 µm Spitze verjüngt ist. Eingebaut in eine 22 mm lange und 0,4 mm dicke Edelstahlnadel, kann sie eine Septummembran oder ähnliches Material durchdringen. Sie sind ideal für Sauerstoffprofile in Sedimenten und Biofilmen.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eMicroFlow\u003c\/strong\u003e – \u003cimg style=\"float: right;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/oxyMicroflow_sml_81f476fe-1f6f-43a5-bac6-8a2ba4ae449f.jpg?v=1765947319\" alt=\"\" align=\"right\"\u003eDer MicroFlow-Sauerstoffsensor (501657) ist ein miniaturisierter faseroptischer chemischer Sensor, optimiert für schnelle Ansprechzeit (t90 \u0026lt; 1 Sekunde in Gasen, \u0026lt; 5 Sekunden in Flüssigkeiten). Die winzige Sonde hat eine Spitzenbreite von 50 µm und ist in eine T-förmige Durchflusszelle integriert, die eine einfache Verbindung über Luer-Lock-Adapter zu externen Schläuchen ermöglicht. Flüssigkeiten (wie Wasser, Blut usw.) können durch die Zelle gepumpt werden.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eMicroImplant\u003c\/strong\u003e – \u003cimg style=\"float: right;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/oxyMicroImplant_sml_06ecca35-7943-4c87-b737-c1081be8d559.jpg?v=1765947324\" alt=\"\" align=\"right\"\u003eDer MicroImplant-Sauerstoffsensor (501658) ist eine implantierbare Sonde (IMP) mit einer Sondenspitze von 50 µm, einer freiliegenden Faserlänge von 5 mm und einem Manteldurchmesser von 900 µm. Er wurde erfolgreich in Krabben, Fischen und Boden implantiert.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/OxyMicro-IM-022003.pdf\" target=\"_self\"\u003eOxyMicro Bedienungsanleitung\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd\u003e \u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMiniTip\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMiniFlow\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMiniSpot\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMicroTip\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMicroFlow\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMicroImplant\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eMESSBEREICH\u003cbr\u003eGELÖST\/GASFÖRMIG\u003c\/td\u003e\r\n\u003ctd\u003e0-45 ppm, 0-100%\u003cbr\u003e0-760 mmHg\u003c\/td\u003e\r\n\u003ctd\u003e0-45 ppm, 0-100%\u003cbr\u003e0-760 mmHg\u003c\/td\u003e\r\n\u003ctd\u003e0-45 ppm, 0-100%\u003cbr\u003e0-760 mmHg\u003c\/td\u003e\r\n\u003ctd\u003e0-45 ppm, 0-100%\u003cbr\u003e0-760 mmHg\u003c\/td\u003e\r\n\u003ctd\u003e0-45 ppm, 0-100%\u003cbr\u003e0-760 mmHg\u003c\/td\u003e\r\n\u003ctd\u003e0-45 ppm, 0-100%\u003cbr\u003e0-760 mmHg\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eANSPRECHZEIT [T₉₀]\u003cbr\u003eGELÖST\/GASFÖRMIG\u003c\/td\u003e\r\n\u003ctd\u003e40 s\u003cbr\u003e10 s\u003c\/td\u003e\r\n\u003ctd\u003e40 s\u003cbr\u003e10 s\u003c\/td\u003e\r\n\u003ctd\u003e40 s\u003cbr\u003e10 s\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 2 s\u003cbr\u003e\u0026lt; 0,5 s\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 2 s\u003cbr\u003e\u0026lt; 0,5 s\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 2 s\u003cbr\u003e\u0026lt; 0,5 s\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eSTERILISATION\u003cbr\u003eETOH, H₂O₂\u003cbr\u003eAUTOCLAVIERBAR*\u003c\/td\u003e\r\n\u003ctd\u003e\n\u003cbr\u003eJ\u003cbr\u003eN\u003c\/td\u003e\r\n\u003ctd\u003e\n\u003cbr\u003eJ\u003cbr\u003eJ\u003c\/td\u003e\r\n\u003ctd\u003e\n\u003cbr\u003eJ\u003cbr\u003eJ\u003c\/td\u003e\r\n\u003ctd\u003e\n\u003cbr\u003eJ\u003cbr\u003eN\u003c\/td\u003e\r\n\u003ctd\u003e\n\u003cbr\u003eJ\u003cbr\u003eJ\u003c\/td\u003e\r\n\u003ctd\u003e\n\u003cbr\u003eJ\u003cbr\u003eJ\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDRIFT**\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 0,1%\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 0,1%\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 0,1%\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 0,3%\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 0,3%\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 0,3%\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eGENAUIGKEIT***\u003c\/td\u003e\r\n\u003ctd colspan=\"6\"\u003e0.2%\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAUFLÖSUNG***\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" colspan=\"6\"\u003e2,75 ±0,01 ppm, 9,00 ±0,05 ppm, 220 ±0,15 ppm, 45,0 ±0,25 mmHg,\u003cbr\u003e150 ±0,75 mmHg, 375 ±2,6 mmHg\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eTEMPERATURBEREICH\u003c\/td\u003e\r\n\u003ctd colspan=\"6\"\u003e-10°C bis 50°C\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSONDENBAU-LÄNGE\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" colspan=\"6\"\u003e2,5 m\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: center;\" colspan=\"7\"\u003e*130°C, 1,5 atm  **100.000 Datenpunkte, 20°C  ***20°C\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266219446362,"sku":"OXY-MICRO-AOT","price":11800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/oxy-micro-aot_1_d293e2ac-b44f-401e-b9af-02bccdf0a2d8.jpg?v=1766399001"},{"product_id":"oxy-mini-aot-fiber-optic-oxygen-meter-for-minisensors","title":"Faseroptisches Sauerstoffmessgerät für Minisensoren","description":"\u003c!-- section:details --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/OxyMini.pdf\" target=\"_self\"\u003eHier klicken, um das aktuelle \u003cstrong\u003eDatenblatt\u003c\/strong\u003e anzusehen\u003c\/a\u003e.\u003c\/p\u003e\r\n\u003ch2\u003eEigenschaften\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eSauerstoff wird während des Experiments nicht verbraucht\u003c\/li\u003e\r\n\u003cli\u003eUnempfindlich gegenüber elektrischen und magnetischen Störungen\u003c\/li\u003e\r\n\u003cli\u003eAusgezeichnete Langzeitstabilität\u003c\/li\u003e\r\n\u003cli\u003eKeine langwierige Polarisation notwendig (wie bei Clark-Typ O2-Elektroden)\u003c\/li\u003e\r\n\u003cli\u003eSchnelle Ansprechzeit \u0026lt; 0,5 s für MicroTip-Sensoren\u003c\/li\u003e\r\n\u003cli\u003eSondengröße der MicroTip-Sensoren bis zu 50 µm klein\u003c\/li\u003e\r\n\u003cli\u003eMessung ist auch in trockenem Gas möglich\u003c\/li\u003e\r\n\u003cli\u003eOptische Isolierung der Sensorspitze verfügbar für fluoreszierende oder photosynthetisch aktive Proben\u003c\/li\u003e\r\n\u003cli\u003eDie Sensoren sind nicht im System enthalten\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eVorteile\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eUnempfindlich gegenüber Lichtquellenstabilität und Intensitätsschwankungen, da sie auf Lumineszenz-Lebensdauer-Messungen basieren.\u003c\/li\u003e\r\n\u003cli\u003eKompakte, tragbare Messgeräte können innen oder außen verwendet werden\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eAnwendungen\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eProzesskontrolle wie Abfüllanlagen in Brauereien und Qualitätskontrolle von Verpackungen (OxyMini)\u003c\/li\u003e\r\n\u003cli\u003eBiotechnologie wie Kontrolle von Zellkulturmedien und nicht-invasive Kontrolle von Bioreaktoren (OxyMini)\u003c\/li\u003e\r\n\u003cli\u003eImplantation von Sauerstoffsensoren in Boden und Bäume (OxyMini)\u003c\/li\u003e\r\n\u003cli\u003eSauerstoffprofile von marinem Sediment, Böden oder Gewebe (OxyMicro)\u003c\/li\u003e\r\n\u003cli\u003eImplantation in lebendes Gewebe wie Herz- oder Muskelgewebe (OxyMicro)\u003c\/li\u003e\r\n\u003cli\u003eKontrolle von Zellkulturmedien in der Biotechnologie (OxyMicro)\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eUnempfindlich gegenüber Lichtquellenstabilität und Intensität\u003c\/h2\u003e\r\n\u003cp\u003eKonventionelle faseroptische Sauerstoffsensor-Systeme, die auf Intensitätsmessungen basieren, sind in ihrer Genauigkeit durch die Stabilität der Lichtquelle und Umgebungslichtschwankungen begrenzt. Durch die Verwendung der Lumineszenz-Lebensdauer-Messung werden Messungen nicht durch Lichtquellenstabilität, Intensitätsschwankungen durch Faserbiegung oder Änderungen der optischen Eigenschaften der Probe (Trübung, Brechungsindex, Färbung usw.) beeinflusst.\u003c\/p\u003e\r\n\u003cp\u003eKalibrierung: Die Sensoren können durch eine einfache Zweipunktkalibrierung kalibriert werden, 100 % Luftsättigung und 0 % Luftsättigung.\u003c\/p\u003e\r\n\u003ch2\u003eKompakte, tragbare Messgeräte für Innen- und Außenbereich\u003c\/h2\u003e\r\n\u003cp\u003eDie OxiMini- und OxyMicro-faseroptischen Sauerstoffmessgeräte sind kompakt und leicht zu transportieren. Für den Innen- und Außenbereich konzipiert, können sie über eine RS232-Schnittstelle an einen PC angeschlossen werden. Daten können mit der mitgelieferten Software visualisiert, analysiert und gespeichert werden. Eine vollständige Sensorpalette ist verfügbar.\u003c\/p\u003e\r\n\u003ch2\u003eOxyMini-Systeme\u003c\/h2\u003e\r\n\u003cp\u003eDer \u003cstrong\u003eOxyMini\u003c\/strong\u003e ist ein einkanaliges faseroptisches O\u003csub\u003e2\u003c\/sub\u003e-Messgerät für faseroptische O\u003csub\u003e2\u003c\/sub\u003e-Minisensoren. Diese Sensoren basieren auf 2 mm Polymer-Glasfasern und haben eine Länge von 2,5 m.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eMiniTip\u003c\/strong\u003e – Diese Tauchsonde (501641) hat einen Spitzen-Durchmesser von 4 mm und besteht aus einer Polymer-Glasfaser mit einer O2-sensitiven Beschichtung. Ihr Messbereich liegt bei 0–100%. Die Ansprechzeit (t90) beträgt ca. 40 s.\u003cimg style=\"float: right;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/oxyMiniTip_sml_65860f24-c8a4-4398-8735-7536d2330b4e.jpg?v=1765947337\" alt=\"oxyMiniTip\" width=\"250\" height=\"41\" align=\"right\"\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eMiniFlow\u003c\/strong\u003e – Die MiniFlow-Sonde (501642) ist ein miniaturisierter faseroptischer chemischer Sensor, integriert in eine standardmäßige T-förmige Durchflusszelle, die einfach über Luer-Lock-Adapter an externe Schläuche angeschlossen werden kann. Flüssigkeiten können durch die Zelle gepumpt werden. Sie hat eine Ansprechzeit (t90) von ca. 40 s und eine ausgezeichnete Langzeitstabilität.\u003cimg style=\"float: right;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/oxyMiniFlow_sml_28bc6e12-f670-4fcc-9587-a97e8310d3e2.jpg?v=1765947342\" alt=\"oxyMiniFlow\" width=\"250\" height=\"74\" align=\"right\"\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eMiniFoil\u003c\/strong\u003e – Sensormaterial auf einer 1cm² großen Trägerscheibe aus Polyester, die innen in Glasfläschchen geklebt werden kann. Messen Sie die Sauerstoffkonzentration nicht-invasiv und zerstörungsfrei von außen durch die Wand des Fläschchens. Beleuchten Sie die Sensorfolie mit einem Kunststoff-Faseroptikkabel (501644, 01645). Die Wand des Fläschchens muss transparent\/nicht fluoreszierend sein. (Ansprechzeit (t90) ca. 50 s.) Das Material kann in Tiergewebe oder maßgefertigte Gehäuse implantiert werden. \u003cimg style=\"float: right;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/oxyMiniFoil_sml_fedeffb5-3fa5-46a3-bd95-732f2f44fc2b.jpg?v=1765947348\" alt=\"oxyMiniFoil\" width=\"191\" height=\"162\" align=\"right\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eDas OxyMini-System ist für Prozesssteuerung und biotechnologische Anwendungen optimiert. Das Messprinzip des Sensorsystems basiert auf der Erfassung der Sauerstoffkonzentration als Funktion der Lumineszenzlebensdauer, entweder in gelöster oder gasförmiger Phase. Das faseroptische Sauerstoffmessgerät ist kompakt und leicht zu transportieren. Es wurde für den Innen- und Außeneinsatz entwickelt und kann über eine RS232-Schnittstelle an einen PC angeschlossen werden. Daten können mit der mitgelieferten Software visualisiert, analysiert und gespeichert werden. Eine vollständige Palette von Sensoren, die die meisten biomedizinischen Anwendungen abdecken, ist verfügbar.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eMessprinzip\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eKonventionelle faseroptische Sauerstoffsensor-Systeme, die auf Intensitätsmessungen basieren, sind in ihrer Genauigkeit durch die Stabilität der Lichtquelle und Schwankungen des Umgebungslichts begrenzt. Durch die Verwendung einer Lumineszenz-Lebensdauererkennung werden Messungen nicht durch die Stabilität der Lichtquelle, Intensitätsschwankungen durch Faserbiegung oder Änderungen der optischen Eigenschaften der Probe (Trübung, Brechungsindex, Färbung usw.) beeinflusst. Diese Vorteile machen WPI's OxyMini und OxyMicro zum fortschrittlichsten und zuverlässigsten faseroptischen Sauerstoffsystem auf dem Markt.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eKalibrierung\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDie Sensoren können durch eine einfache Zweipunktkalibrierung kalibriert werden, 100% Luftsättigung und 0% Luftsättigung.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/OxyMini-IM-073003r.pdf\" target=\"_self\"\u003eOxyMini Bedienungsanleitung\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd\u003e \u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMiniTip\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMiniFlow\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMiniSpot\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMicroTip\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMicroFlow\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eMicroImplant\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eMESSBEREICH\u003cbr\u003eGELÖST\/GASFÖRMIG\u003c\/td\u003e\r\n\u003ctd\u003e0-45 ppm, 0-100%\u003cbr\u003e0-760 mmHg\u003c\/td\u003e\r\n\u003ctd\u003e0-45 ppm, 0-100%\u003cbr\u003e0-760 mmHg\u003c\/td\u003e\r\n\u003ctd\u003e0-45 ppm, 0-100%\u003cbr\u003e0-760 mmHg\u003c\/td\u003e\r\n\u003ctd\u003e0-45 ppm, 0-100%\u003cbr\u003e0-760 mmHg\u003c\/td\u003e\r\n\u003ctd\u003e0-45 ppm, 0-100%\u003cbr\u003e0-760 mmHg\u003c\/td\u003e\r\n\u003ctd\u003e0-45 ppm, 0-100%\u003cbr\u003e0-760 mmHg\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eANSPRECHZEIT [T₉₀]\u003cbr\u003eGELÖST\/GASFÖRMIG\u003c\/td\u003e\r\n\u003ctd\u003e40 s\u003cbr\u003e10 s\u003c\/td\u003e\r\n\u003ctd\u003e40 s\u003cbr\u003e10 s\u003c\/td\u003e\r\n\u003ctd\u003e40 s\u003cbr\u003e10 s\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 2 s\u003cbr\u003e\u0026lt; 0,5 s\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 2 s\u003cbr\u003e\u0026lt; 0,5 s\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 2 s\u003cbr\u003e\u0026lt; 0,5 s\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eSTERILISATION\u003cbr\u003eETOH, H₂O₂\u003cbr\u003eAUTOCLAVIERBAR*\u003c\/td\u003e\r\n\u003ctd\u003e\n\u003cbr\u003eJ\u003cbr\u003eN\u003c\/td\u003e\r\n\u003ctd\u003e\n\u003cbr\u003eJ\u003cbr\u003eJ\u003c\/td\u003e\r\n\u003ctd\u003e\n\u003cbr\u003eJ\u003cbr\u003eJ\u003c\/td\u003e\r\n\u003ctd\u003e\n\u003cbr\u003eJ\u003cbr\u003eN\u003c\/td\u003e\r\n\u003ctd\u003e\n\u003cbr\u003eJ\u003cbr\u003eJ\u003c\/td\u003e\r\n\u003ctd\u003e\n\u003cbr\u003eJ\u003cbr\u003eJ\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDRIFT**\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 0,1%\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 0,1%\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 0,1%\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 0,3%\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 0,3%\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 0,3%\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eGENAUIGKEIT***\u003c\/td\u003e\r\n\u003ctd colspan=\"6\"\u003e0.2%\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAUFLÖSUNG***\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" colspan=\"6\"\u003e2,75 ±0,01 ppm, 9,00 ±0,05 ppm, 220 ±0,15 ppm, 45,0 ±0,25 mmHg,\u003cbr\u003e150 ±0,75 mmHg, 375 ±2,6 mmHg\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eTEMPERATURBEREICH\u003c\/td\u003e\r\n\u003ctd colspan=\"6\"\u003e-10°C bis 50°C\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSONDENLÄNGE\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\" colspan=\"6\"\u003e2,5 m\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: center;\" colspan=\"7\"\u003e*130°C, 1,5 atm  **100.000 Datenpunkte, 20°C  ***20°C\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266219479130,"sku":"OXY-MINI-AOT","price":11200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/oxy-mini-aot_d927bea9-d4e2-4acc-ac90-f380e777b0eb.jpg?v=1766399011"},{"product_id":"var-7803-oxygen-sensor","title":"Sauerstoffsensor","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eErkennung von O2 für Echtzeitanalysen\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eFluoreszenzdetektor für optische Sensoren, eine praktikable Alternative zu herkömmlichen chemischen Sensoren\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eMessung von Fluoreszenzlebensdauer, Phase und Intensität\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLED-basierte Photometrie macht dieses Gerät erschwinglich – halb so teuer wie vergleichbare Phasenmesssysteme\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAusgezeichnete Stabilität, extrem geringe Drift und Phasenrauschen\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eEinfache Kalibrierung, Einrichtung und Steuerung\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003eSauerstoffüberwachungskit, inklusive:\r\n\u003cul\u003e\r\n\u003cli\u003ePhasenmesssystem\u003c\/li\u003e\r\n\u003cli\u003eTemperatursonde \u003c\/li\u003e\r\n\u003cli\u003eSensorpatches bei Bestellung auswählen\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptionen\u003c\/h2\u003e\r\n\u003ctable style=\"width: 743px;\" border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 136.063px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eBestellcode\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 592.938px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eBeschreibung\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd style=\"width: 136.063px;\"\u003eFLOX-PATCH\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 592.938px;\"\u003eNicht-invasives Sauerstoffüberwachungskit, inklusive Phasenmesssystem, Temperatursonde; Sensorpatches bei Bestellung auswählen\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr bgcolor=\"#e6e6e6\"\u003e\r\n\u003ctd style=\"width: 136.063px;\"\u003eFLOX-PROBE\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 592.938px;\"\u003e\u003cspan class=\"CharOverride-15\"\u003eIn-Situ-Sauerstoffüberwachungskit, inklusive Phasenmesssystem, Temperatursonde; Sensor bei Bestellung auswählen\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003ch2\u003e Vorteile\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eEigenständiges Tischgerät – unempfindlich gegenüber Faserknicken oder Streulicht\u003c\/li\u003e\r\n\u003cli\u003eEinfache Einrichtung und Steuerung, kombiniert mit Stabilität und Empfindlichkeit, machen dieses Gerät perfekt für Langzeitstudien\u003c\/li\u003e\r\n\u003cli\u003eDrei Beschichtungen für Sonden und Patches bieten viele Optionen\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eAnwendungen\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eSauerstoffmessanwendungen, die Stabilität und Empfindlichkeit gegenüber Drift erfordern und über längere Zeit ungestört bleiben müssen\u003c\/li\u003e\r\n\u003cli\u003eÜberwachen Sie den O₂-Partialdruck in Gasen und wässrigen Lösungen sowie in nicht-wässrigen Dämpfen und Lösungen\u003cbr\u003eÜberwachen Sie Spuren von Sauerstoff in Gasen und Flüssigkeiten\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cstrong\u003eFLOX\u003c\/strong\u003e ist ein Gerät zur Messung von Fluoreszenzlebensdauer, Phase und Intensität. Es verwendet LED-Anregung und Photodiodendetektion mit filterbasierter Wellenlängenauswahl für eine einfache experimentelle Einrichtung und Steuerung.\u003c\/p\u003e\r\n\u003ch2\u003eEigenständiges Gerät\u003c\/h2\u003e\r\n\u003cp\u003eDas kompakte, eigenständige Gerät macht es unempfindlich gegenüber Faserknicken und Streulicht. Es verfügt außerdem über einen großen dynamischen Bereich der optischen Intensität sowie geringe optische und elektronische Übersprechungen und niedrige Drift- und Phasenrauschen.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eFLOX\u003c\/strong\u003e ist besonders nützlich für Sauerstoffmessanwendungen, bei denen Stabilität und Empfindlichkeit gegenüber Drift wichtig sind und bei denen Probenaufbauten über lange Zeiträume ungestört bleiben müssen.\u003c\/p\u003e\r\n\u003ch2\u003eEinfache Einrichtung, ideal für Langzeitstudien\u003c\/h2\u003e\r\n\u003cp\u003eDas neue Sauerstoffmesssystem misst Fluoreszenzlebensdauer, Phase und Intensität, verwendet LED-Anregung und Photodiodendetektion mit filterbasierter Wellenlängenauswahl. Das System ist einfach einzurichten und zu steuern. Wenn Stabilität und Empfindlichkeit gegenüber Drift in Ihrem Sauerstoffmess-Experiment wichtig sind, ist dieses Gerät ideal. Es ist perfekt für Anwendungen, bei denen Probenaufbauten über lange Zeiträume ungestört bleiben müssen.\u003c\/p\u003e\r\n\u003ch2\u003eDrei Beschichtungen für Sonden und Patches verfügbar\u003c\/h2\u003e\r\n\u003cp\u003eDie optischen Sensoren bestehen aus Wandler-Materialien, die auf die Spitzen von Lichtwellenleitern oder auf Substrate wie Patches oder Küvetten aufgebracht sind und ihre optischen Eigenschaften als Reaktion auf spezifische Analyten in ihrer unmittelbaren Umgebung verändern.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eOXY\u003c\/strong\u003e–Der Standard-Sauerstoffsensor zur Überwachung des Sauerstoff-Partialdrucks in Gasen und wässrigen Lösungen ist eine faseroptische Fluoreszenzsonde mit einer proprietären, sauerstoffempfindlichen Beschichtung an der Spitze.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eHIOXY\u003c\/strong\u003e – Entwickelt zur Überwachung des Sauerstoffteilchendrucks in nicht-wässrigen Dämpfen und Lösungen. Die Sensorbeschichtungschemie ist kompatibel mit Ölen, Alkoholen und kohlenwasserstoffbasierten Dämpfen und Flüssigkeiten.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eFOSPOR\u003c\/strong\u003e – Eine neue Generation hochsensibler Sensorbeschichtungen, die zur Überwachung von Sauerstoffspuren in Gasen und Flüssigkeiten verwendet werden kann.\u003c\/p\u003e\r\n\u003cp\u003eDie Sauerstoffsensor-Sonden sind energiesparend und bieten hohe Empfindlichkeit, Reversibilität und Stabilität, ideal für die Fernüberwachung. Die dünne Beschichtung an den Sondenspitzen verbraucht keinen Sauerstoff, was eine kontinuierliche Probenkontaktierung ermöglicht. Sie sind ideal für viskose Proben und unempfindlich gegenüber Störungen durch pH-, Ionenstärken- oder Salzgehaltsschwankungen sowie Biofouling.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/10_orig_71ef576f-84ef-40c5-8472-e98fd8fc684e.png?v=1765948947\" alt=\"Sauerstoffmessungen\" width=\"400\" height=\"237\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eFLOX-Software zeigt Sauerstoffmessungen auf einem verbundenen PC an.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd style=\"width: 200px;\"\u003e\u003cstrong\u003eSonden-Spezifikationen\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\n\u003cstrong\u003eOXY-Formulierung\u003c\/strong\u003e \u003cstrong\u003e(Allzweckbeschichtung)\u003c\/strong\u003e\n\u003c\/td\u003e\r\n\u003ctd\u003e\n\u003cstrong\u003eFOSPOR-Formulierung\u003c\/strong\u003e \u003cstrong\u003e(hohe Empfindlichkeit für niedrige \u003c\/strong\u003e\u003cstrong\u003eO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/strong\u003e\n\u003c\/td\u003e\r\n\u003ctd\u003e\n\u003cstrong\u003eHIOXY-Formulierung\u003c\/strong\u003e \u003cstrong\u003e(für Kohlenwasserstoff-Umgebungen)\u003c\/strong\u003e\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eO\u003csub\u003e2\u003c\/sub\u003e% Bereich (bei 1 ATM)\u003c\/td\u003e\r\n\u003ctd\u003e0-100%\u003c\/td\u003e\r\n\u003ctd\u003e0-\u0026lt;10%\u003c\/td\u003e\r\n\u003ctd\u003e0-20.9%\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDO-Bereich (ppm bei 1 ATM)\u003c\/td\u003e\r\n\u003ctd\u003e0-40 ppm\u003c\/td\u003e\r\n\u003ctd\u003e0-4 ppm\u003c\/td\u003e\r\n\u003ctd\u003e0-8 ppm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eTemperaturbereich\u003c\/td\u003e\r\n\u003ctd\u003e-50 bis +80ºC für Sonden\u003c\/td\u003e\r\n\u003ctd\u003e0 bis +60ºC für Sonden\u003c\/td\u003e\r\n\u003ctd\u003e-50 bis +60ºC\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e0-60 ºC für Patches\u003c\/td\u003e\r\n\u003ctd\u003e0-60ºC für Patches\u003c\/td\u003e\r\n\u003ctd\u003eNicht zutreffend\u003c\/td\u003e\r\n\u003ctd\u003e \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eO\u003csub\u003e2\u003c\/sub\u003e% Auflösung\u003c\/td\u003e\r\n\u003ctd\u003e100 ppm im Gas\u003c\/td\u003e\r\n\u003ctd\u003e10 ppm im Gas\u003c\/td\u003e\r\n\u003ctd\u003e100 ppm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDO-Auflösung (bei Raumtemperatur)\u003c\/td\u003e\r\n\u003ctd\u003e4 ppb\u003c\/td\u003e\r\n\u003ctd\u003e0,4 ppb\u003c\/td\u003e\r\n\u003ctd\u003e4 ppb\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eO\u003csub\u003e2\u003c\/sub\u003e% Genauigkeit\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt;5% des Messwerts\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt;5% des Messwerts\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt;5% des Messwerts\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDO-Genauigkeit\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt;5% des Messwerts\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt;5% des Messwerts\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt;5% des Messwerts\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eMin. nachweisbare Konzentration im Gas\u003c\/td\u003e\r\n\u003ctd\u003e0.01% - 0.05%\u003c\/td\u003e\r\n\u003ctd\u003e0.001% - 0.01%\u003c\/td\u003e\r\n\u003ctd\u003e0.01% - 0.05%\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAnsprechzeit (im Gas)\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 1 Sekunde\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 30-60 Sekunden\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 1 Sekunde\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eAnsprechzeit mit Überzug im Gas\u003c\/td\u003e\r\n\u003ctd\u003e45-60 Sekunden\u003c\/td\u003e\r\n\u003ctd\u003e60-90 Sekunden\u003c\/td\u003e\r\n\u003ctd\u003e \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAnsprechzeit in reinem Wasser\u003c\/td\u003e\r\n\u003ctd\u003e30-45 Sekunden\u003c\/td\u003e\r\n\u003ctd\u003e60-90 Sekunden\u003c\/td\u003e\r\n\u003ctd\u003e~45 Sekunden\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd style=\"width: 200px;\"\u003e\u003cstrong\u003ePatch-Spezifikationen\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\n\u003cstrong\u003eOXY-Formulierung\u003c\/strong\u003e \u003cstrong\u003e(Allzweckbeschichtung)\u003c\/strong\u003e\n\u003c\/td\u003e\r\n\u003ctd\u003e\n\u003cstrong\u003eFOSPOR-Formulierung\u003c\/strong\u003e \u003cstrong\u003e(hohe Empfindlichkeit für niedrige \u003c\/strong\u003e\u003cstrong\u003eO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/strong\u003e\n\u003c\/td\u003e\r\n\u003ctd\u003e\n\u003cstrong\u003eHIOXY-Formulierung\u003c\/strong\u003e \u003cstrong\u003e(für Kohlenwasserstoff-Umgebungen)\u003c\/strong\u003e\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eO\u003csub\u003e2\u003c\/sub\u003e% Bereich (bei 1 ATM)\u003c\/td\u003e\r\n\u003ctd\u003e0-100%\u003c\/td\u003e\r\n\u003ctd\u003e0-10%\u003c\/td\u003e\r\n\u003ctd\u003e0-20%\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDO-Bereich (ppm bei 1 ATM)  \u003c\/td\u003e\r\n\u003ctd\u003e0-40 ppm\u003c\/td\u003e\r\n\u003ctd\u003e0-4 ppm\u003c\/td\u003e\r\n\u003ctd\u003e0-8 ppm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eTemperaturbereich\u003c\/td\u003e\r\n\u003ctd\u003e-20 bis +60 ºC für Patches\u003c\/td\u003e\r\n\u003ctd\u003e0 bis +60 ºC für Patches\u003c\/td\u003e\r\n\u003ctd\u003e-20 bis +60 ºC für Patches\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eO\u003csub\u003e2\u003c\/sub\u003e% Auflösung (20 Sekunden Mittelung)\u003c\/td\u003e\r\n\u003ctd\u003e0.05%\u003c\/td\u003e\r\n\u003ctd\u003e0.01%\u003c\/td\u003e\r\n\u003ctd\u003e \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003e (bei 30 Sekunden Mittelung)\u003c\/td\u003e\r\n\u003ctd\u003e0.05%\u003c\/td\u003e\r\n\u003ctd\u003e \u003c\/td\u003e\r\n\u003ctd\u003e \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDO-Auflösung (bei Raumtemperatur)\u003c\/td\u003e\r\n\u003ctd\u003e20 ppb\u003c\/td\u003e\r\n\u003ctd\u003e4 ppb\u003c\/td\u003e\r\n\u003ctd\u003e20 ppb\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eO\u003csub\u003e2\u003c\/sub\u003e% Genauigkeit\u003c\/td\u003e\r\n\u003ctd\u003e5% des Messwerts\u003c\/td\u003e\r\n\u003ctd\u003e5% des Messwerts\u003c\/td\u003e\r\n\u003ctd\u003e5% des Messwerts\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDO-Genauigkeit\u003c\/td\u003e\r\n\u003ctd\u003e5% des Messwerts\u003c\/td\u003e\r\n\u003ctd\u003e5% des Messwerts\u003c\/td\u003e\r\n\u003ctd\u003e5% des Messwerts\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eMin. nachweisbare Konzentration \u003c\/td\u003e\r\n\u003ctd\u003e0,1% O\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\r\n\u003ctd\u003e0,01% O\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\r\n\u003ctd\u003e \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e  (bei 30 Sekunden Mittelung)\u003c\/td\u003e\r\n\u003ctd\u003e0,1% O\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\r\n\u003ctd\u003e \u003c\/td\u003e\r\n\u003ctd\u003e \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eMinimal nachweisbare Konzentration im Wasser (Raumtemperatur)\u003c\/td\u003e\r\n\u003ctd\u003e40 ppb    \u003c\/td\u003e\r\n\u003ctd\u003e4 ppb\u003c\/td\u003e\r\n\u003ctd\u003e40 ppb\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAnsprechzeit (im Gas)\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt;1 Sekunde\u003c\/td\u003e\r\n\u003ctd\u003e30-60 Sekunden\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt;1 Sekunde\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eAnsprechzeit mit Überzug im Gas\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e~30-45 Sekunden\u003c\/td\u003e\r\n\u003ctd\u003e~60-90 Sekunden\u003c\/td\u003e\r\n\u003ctd\u003e \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAnsprechzeit in reinem Wasser\u003c\/td\u003e\r\n\u003ctd\u003e~45 Sekunden\u003c\/td\u003e\r\n\u003ctd\u003e~60-90 Sekunden\u003c\/td\u003e\r\n\u003ctd\u003e~30-45 Sekunden\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd style=\"width: 200px;\"\u003e\u003cstrong\u003eStabilität (kontinuierliche LED)\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\n\u003cstrong\u003eOXY-Formulierung\u003c\/strong\u003e \u003cstrong\u003e(Allzweckbeschichtung)\u003c\/strong\u003e\n\u003c\/td\u003e\r\n\u003ctd\u003e\n\u003cstrong\u003eFOSPOR-Formulierung\u003c\/strong\u003e \u003cstrong\u003e(hohe Empfindlichkeit für niedrige \u003c\/strong\u003e\u003cstrong\u003eO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/strong\u003e\n\u003c\/td\u003e\r\n\u003ctd\u003e\n\u003cstrong\u003eHIOXY-Formulierung\u003c\/strong\u003e \u003cstrong\u003e(für Kohlenwasserstoff-Umgebungen)\u003c\/strong\u003e\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eLebensdauerstabilität (Tau)\u003c\/td\u003e\r\n\u003ctd\u003e0,0006 µs\/HR\u003c\/td\u003e\r\n\u003ctd\u003e0,003 µs\/HR\u003c\/td\u003e\r\n\u003ctd\u003e0,0002 µs\/HR\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSauerstoffstabilität %\u003c\/td\u003e\r\n\u003ctd\u003e0,01% HR\u003c\/td\u003e\r\n\u003ctd\u003e0,005% HR\u003c\/td\u003e\r\n\u003ctd\u003e0,007% HR\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd style=\"width: 200px;\"\u003e\u003cstrong\u003eSterilisationsanleitung\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\n\u003cstrong\u003eOXY-Formulierung\u003c\/strong\u003e \u003cstrong\u003e(Allzweckbeschichtung)\u003c\/strong\u003e\n\u003c\/td\u003e\r\n\u003ctd\u003e\n\u003cstrong\u003eFOSPOR-Formulierung\u003c\/strong\u003e \u003cstrong\u003e(hohe Empfindlichkeit für niedrige \u003c\/strong\u003e\u003cstrong\u003eO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/strong\u003e\n\u003c\/td\u003e\r\n\u003ctd\u003e\n\u003cstrong\u003eHIOXY-Formulierung\u003c\/strong\u003e \u003cstrong\u003e(für Kohlenwasserstoff-Umgebungen)\u003c\/strong\u003e\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eFormfaktor\u003c\/td\u003e\r\n\u003ctd\u003eSonden\/Patches\u003c\/td\u003e\r\n\u003ctd\u003eSonden\/Patches\u003c\/td\u003e\r\n\u003ctd\u003eSonden\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAutoklavierbar\u003c\/td\u003e\r\n\u003ctd\u003eNein\u003c\/td\u003e\r\n\u003ctd\u003eNoch nicht bestimmt\u003c\/td\u003e\r\n\u003ctd\u003eJa\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd\u003eKalibrierung\u003c\/td\u003e\r\n\u003ctd\u003e \u003c\/td\u003e\r\n\u003ctd\u003e \u003c\/td\u003e\r\n\u003ctd\u003eNach Sterilisation ist ein Einzelpunkt-Reset erforderlich\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eGamma\u003c\/td\u003e\r\n\u003ctd\u003eJa\u003c\/td\u003e\r\n\u003ctd\u003eNoch nicht bestimmt\u003c\/td\u003e\r\n\u003ctd\u003eJa\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003ch2\u003eAuch verfügbare Optionen\u003c\/h2\u003e\r\n\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"2\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cstrong\u003eAL300\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003eEine 500 µm Außendurchmesser (300 µm Kerndurchmesser) aluminiumummantelte Glasfasersonde für Anwendungen, die eine feine räumliche Auflösung erfordern. 300 µm aluminiumummantelte Faserbaugruppe; 500 µm Außendurchmesser, 1 m Länge\u003c\/td\u003e\r\n\u003ctd\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/11_orig.jpg\" alt=\"\"\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cstrong\u003eOR125\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003eDer OR125 ist eine 1\/8\" Außendurchmesser Glasfasersonde, die als direkter Ersatz für 1\/8\" Außendurchmesser O2-Elektroden verwendet wird.\u003cbr\u003e100 µm Glasfaser, Edelstahl-Ferrule; 3,175 mm Außendurchmesser, 63,5 mm Länge\u003c\/td\u003e\r\n\u003ctd\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/12_orig.jpg\" alt=\"\" width=\"131\" height=\"96\"\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\n\u003cstrong\u003eP1600\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\r\n\u003ctd\u003eDer PI600 ist eine mit Silikon ummantelte, polyimidbeschichtete Glasfasersonde, die in Umgebungen eingesetzt wird, in denen eine nichtmetallische Sonde erforderlich ist.\u003cbr\u003e200 oder 600 µm Glasfaser mit Silikonmantel; 710 µm Außendurchmesser, 2 m Länge\u003c\/td\u003e\r\n\u003ctd\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/13_orig.jpg\" alt=\"\" width=\"125\" height=\"68\"\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cstrong\u003eOR125G und OR125GT\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003eDiese Sonden sind 1\/8\" Außendurchmesser Glasfasersonden, die als direkter Ersatz für 1\/8\" Außendurchmesser O2-Elektroden verwendet werden.\u003cbr\u003e1000 µm Glasfaser, Edelstahl-Ferrule; 3,175 mm Außendurchmesser, 63,5 mm Länge\u003c\/td\u003e\r\n\u003ctd\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/14_orig.jpg\" alt=\"\" width=\"120\" height=\"100\"\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cstrong\u003eR Sensorsonde\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e1000 µm Faser in einer Edelstahl-Ferrule 1\/16\"; 1,587 mm Außendurchmesser, 152,4 mm Länge\u003c\/td\u003e\r\n\u003ctd\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/15_orig.jpg\" alt=\"\" width=\"128\" height=\"89\"\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"Nicht-invasives Sauerstoffüberwachungskit","offer_id":42266308313178,"sku":"FLOX-PATCH","price":4473.0,"currency_code":"USD","in_stock":true},{"title":"In-situ-Sauerstoffüberwachungskit","offer_id":42266308345946,"sku":"FLOX-PROBE","price":5812.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/flox_4c4c86fb-6b1b-4505-8a49-67ddb508c6b4.jpg?v=1766401214"},{"product_id":"var-505155-deep-uv-qualified-fiber","title":"Qualifiziertes faseroptisches Kabel Tief-UV-NIR","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eEigenschaften\u003c\/h2\u003e\u003cp\u003e\u003cstrong style=\"color: #000000;\"\u003eQVLUX-Serie \u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eFasermaterial: Hochwertiges Silizium\/Silizium-Stufenindex-Multimode\u003c\/li\u003e\r\n\u003cli\u003eKerngröße: 400µm oder 600µm\u003c\/li\u003e\r\n\u003cli\u003eWellenlänge: UV-VIS 180-1200nm\u003c\/li\u003e\r\n\u003cli\u003eNumerische Apertur (NA): 0,22\u003c\/li\u003e\r\n\u003cli\u003eSteckverbinder: \u003cstrong\u003eSMA 905\u003c\/strong\u003e, FC, ST, DIN, F125, F250, LLG\u003c\/li\u003e\r\n\u003cli\u003eMantel: Silikon-Monocoil-Schlauch\u003c\/li\u003e\r\n\u003cli\u003eTemperaturbereich -40°C bis 120°C\u003c\/li\u003e\r\n\u003cli\u003eNiedrigste Dämpfung bei 180 nm\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eQualifizierte Fasern für UV-optische Messungen \u003c\/h2\u003e\r\n\u003cp\u003eWPIs \u003cstrong\u003eQVLUX\u003c\/strong\u003e-Serie wurde entwickelt, um nicht nur eine überlegene Übertragung im UV-Bereich zu bieten, sondern auch eine hervorragende Konsistenz über die Länge. Das macht \u003cstrong\u003eQVLUX\u003c\/strong\u003e zur perfekten Wahl für kritische Messungen oder wenn „Plug-and-Play“-Fähigkeit ohne Neukalibrierung nach einem Faserbaugruppenwechsel erforderlich ist. Standard-Siliziumfaser zeigt einen „Solarisationseffekt“ bei der Übertragung von Licht im UV-Bereich unter ~280nm. Im Laufe der Zeit, abhängig von der optisch übertragenen Leistung, nimmt die Fähigkeit der Faser, UV-Licht zu übertragen, ab. Unsere QVLUX-Faser bietet eine überlegene Resistenz gegen Solarisation. Die niedrigste Grunddämpfung unserer solarisationsresistenten Faser liegt bei 200nm (\u0026lt;1 dB\/m) und die geringste Solarisation bei 214 nm auf dem Markt. WPI ist das einzige Unternehmen, das nach DIN 58145:2018-01 zertifizierte UV-Fasern und Baugruppen mit geringer Solarisation anbietet.   \u003c\/p\u003e\r\n\u003ch2\u003eQVLUX-Serie 1x1 qualifizierte optische Faserkabel-Optionen\u003c\/h2\u003e\r\n\u003ctable style=\"width: 829px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 89px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eBestellcode\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 144px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003e\u003cstrong\u003eKatalog-Teilenummer\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 473px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eBeschreibung \u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 95px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eKerndurchmesser\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"width: 89px;\"\u003e\r\n\u003cp style=\"text-align: center;\"\u003e505155\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd style=\"width: 144px;\"\u003e\r\n\u003cp style=\"text-align: center;\"\u003eQVLUXDUV-S-0400-025-SMA\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd style=\"width: 473px;\"\u003e\r\n\u003cp style=\"text-align: left;\"\u003eQualifizierte Deep-UV-Faser (180-1200nm),  \u003cstrong\u003e25 cm Länge\u003c\/strong\u003e mit SMA 905 Steckverbindern   \u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd style=\"width: 95px;\"\u003e\r\n\u003cp style=\"text-align: left;\"\u003e400 μm \u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"width: 89px;\"\u003e\r\n\u003cp style=\"text-align: center;\"\u003e505156\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd style=\"width: 144px;\"\u003e\r\n\u003cp style=\"text-align: center;\"\u003eQVLUXDUV-S-0400-100-SMA\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd style=\"width: 473px;\"\u003e\r\n\u003cp style=\"text-align: left;\"\u003eQualifizierte Deep-UV-Faser (180-1200nm),\u003cstrong\u003e 1 m Länge\u003c\/strong\u003e mit SMA 905 Steckverbindern\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 95px;\"\u003e400 μm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd style=\"width: 89px;\"\u003e\r\n\u003cp style=\"text-align: center;\"\u003e505157\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd style=\"width: 144px;\"\u003e\r\n\u003cp style=\"text-align: center;\"\u003eQVLUXDUV-S-0600-025-SMA\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd style=\"width: 473px;\"\u003e\r\n\u003cp style=\"text-align: left;\"\u003eQualifizierte Deep-UV-Faser (180-1200nm),\u003cstrong\u003e 25 cm Länge\u003c\/strong\u003e mit SMA 905 Steckverbindern \u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 95px;\"\u003e600 μm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 89px;\"\u003e505158\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 144px;\"\u003eQVLUXDUV-S-0600-100-SMA\u003c\/td\u003e\r\n\u003ctd style=\"width: 473px;\"\u003eQualifizierte Deep-UV-Faser (180-1200nm),\u003cstrong\u003e 1 Meter Länge\u003c\/strong\u003e mit SMA 905 Steckverbindern \u003c\/td\u003e\r\n\u003ctd style=\"width: 95px;\"\u003e600 μm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd style=\"text-align: center; width: 89px;\"\u003e505163\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 144px;\"\u003eWVLUXDUV-S-0200-100-SMA\u003c\/td\u003e\r\n\u003ctd style=\"width: 473px;\"\u003e100cm Spezial-Siliziumfaser mit 200µm Kerndurchmesser (200-1200nm). Geringe Solarisation bei 214nm\u003c\/td\u003e\r\n\u003ctd style=\"width: 95px;\"\u003e200 µm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003ch2\u003eFür bifurkierte Fasern, Kreuzfasern, gemischte optische Faser-Patchkabel und andere faseroptische Baugruppen, die für Ihr spezielles Projekt gefertigt werden, kontaktieren Sie wpi@wpiinc.com.\u003c\/h2\u003e\r\n\u003ch2\u003eVorteile \u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\r\n\u003cp\u003eQualifizierte proprietäre optische Faser ist WPIs fortschrittlichste Produktlinie für optische Fasern. Sehr widerstandsfähig gegen UV-Licht bis 185nm DIN 58145:2017-01\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n\u003cli\u003e\r\n\u003cp\u003eQualifizierte Faser ermöglicht exzellente Übertragung von UV-Licht in langem optischem Faserstrang\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n\u003cli\u003e\r\n\u003cp\u003eWidersteht UV-bedingter Degradation besser als nahezu alle auf dem Markt erhältlichen optischen Fasern\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n\u003cli\u003e\r\n\u003cp\u003eErmöglicht einen echten „Plug-and-Play“-Austausch\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n\u003cli\u003e\r\n\u003cp\u003eIdeal für OEM und Anwendungen, die Außendienst erfordern oder bei denen mehrere Instrumente für eine Reihe von Tests verwendet werden müssen\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n\u003cli\u003e\r\n\u003cp\u003eEnthält Zertifikat und Daten sowohl zur UV-Transmission als auch zum induzierten Verlust, der durch kontinuierliche Belichtung mit einer 30W-Deuteriumlampe für jede Faser-Materialcharge von 185-360nm erzeugt wird\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eAnwendungen\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eUV-Faseroptik-Spektroskopietechniken, die eine Kopplung an eine Hochleistungs-UV-Quelle, gepulster Laser, erfordern \u003c\/li\u003e\r\n\u003cli\u003eFlüssigkeitschromatographie \u003c\/li\u003e\r\n\u003cli\u003eForensische Medizin\u003c\/li\u003e\r\n\u003cli\u003eUV-Raman \u003c\/li\u003e\r\n\u003cli\u003eMedizin\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eWeitere Faser-Konfigurationen und Fasermaterialien verfügbar: \u003c\/h2\u003e\r\n\u003cp\u003e\u003ca href=\"https:\/\/view.publitas.com\/world-precision-instruments\/2019-main-catalog\/page\/165\"\u003ehttps:\/\/view.publitas.com\/world-precision-instruments\/2019-main-catalog\/page\/165\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003ca href=\"\/de\/qualifiedfo\"\u003e\/qualifiedfo\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003ch2\u003eBroschüre\u003c\/h2\u003e\r\n\u003cp\u003e\u003ca title=\"QVLUXDUV Qualified Fiber brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/QVLUXDUV_BR.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/qvluxduv_tn.png\" alt=\"Laden Sie die QVLUXDUV Glasfaser-Broschüre herunter\" width=\"200\" height=\"300\"\u003e\u003c\/a\u003e\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\r\n\u003ch2\u003eVideo\u003c\/h2\u003e\r\n\u003cp\u003eWPI Photonik-Kompetenzzentrum Array optischer Produkte\u003c\/p\u003e\r\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/YjXWnOc2faM?rel=0\" width=\"747\" height=\"420\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003eWPI Optische Fasern Lösungen für Forscher und Produktentwickler\u003c\/p\u003e\r\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/pesp2ugr4Bc?rel=0\" width=\"747\" height=\"420\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ch2\u003eQVLUXDUV STANDARD-SPEZIFIKATIONEN\u003c\/h2\u003e\r\n\u003cp\u003eUnsere QVLUX-Faser wurde so entwickelt, dass sie nicht nur eine überlegene Übertragung im UV-Bereich bietet, sondern auch eine hervorragende Konsistenz über die Länge aufweist. Dies macht QVLUX zur perfekten Wahl für kritische Messungen oder wenn „Plug-and-Play“-Fähigkeit ohne Neukalibrierung nach einem Faserbaugruppenwechsel erforderlich ist. Unsere QVLUX-Faser bietet überlegene Beständigkeit gegen Solarisation, die niedrigste Grunddämpfung bei 200 nm (\u0026lt;1 dB\/m) und die geringste Solarisation bei 214 nm auf dem Markt. WPI ist das einzige Unternehmen, das DIN 58145:2017-01 zertifizierte UV-Fasern mit geringer Solarisation und Baugruppen anbietet. \u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eFasermaterial: Hochwertiges qualifiziertes Siliziumdioxid \/ Siliziumdioxid-Stufenindex Multimode\u003c\/li\u003e\r\n\u003cli\u003eDIN 58145:2018-01\u003c\/li\u003e\r\n\u003cli\u003eVerfügbare Kerndurchmesser: 400 µm, 600 µm\u003c\/li\u003e\r\n\u003cli\u003eWellenlänge: High OH: DUV-VIS 180-1200 nm\u003c\/li\u003e\r\n\u003cli\u003eNumerische Apertur (NA): 0,22\u003c\/li\u003e\r\n\u003cli\u003eAnschluss: \u003cstrong\u003eSMA 905\u003c\/strong\u003e, FC, ST, DIN, F125 (1,25 mm Ferrule), F250 (2,50 mm Ferrule)\u003c\/li\u003e\r\n\u003cli\u003eMantel: Silikon-Monocoil-Schlauch, Edelstahl-Monocoil\u003c\/li\u003e\r\n\u003cli\u003eTemperaturbereich -40°C bis 120°C\u003c\/li\u003e\r\n\u003cli\u003eNiedrigste Dämpfung bei 180 nm \u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/Certificate2.png\" alt=\"UV-NIR Zertifikat\" width=\"786\" height=\"957\"\u003e\u003c\/p\u003e\n\u003c!-- \/section:specifications --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003eWir bieten OEM-Glasfaserkabel, Glasfaserbaugruppen, optische Sonden, optische Durchflusszellen und optische Sensoren an, die entwickelt, hergestellt und getestet werden, um Wiederholbarkeit von einer optischen Baugruppe zur nächsten zu gewährleisten. Als vertrauenswürdiger Partner für zuverlässige optische Messungen bieten wir: Qualifizierte Glasfaser für UV-Instrumentierungsprodukte mit vordefinierten Parametern oder vom Endanwender spezifizierten Parametern, bifurkierte und gekreuzte Glasfaserbaugruppen mit unterschiedlichen Kerndurchmessern und Faserlängen. Anpassungen sind ebenfalls möglich. Für Y-Baugruppen und X-Baugruppen. Liquid Waveguide Kapillarzelle (LWCC) mit langen Weglängen für kleine Probenvolumina für FIA, HPLC und Prozessanalysen. Fluoreszenzsonden zur Erkennung der transienten Reaktion der freien Ionen-Konzentration. Optischer Sauerstoffsensor zur Erkennung von Sauerstoff in lebendem Gewebe. Unsere proprietäre Glasfaserformulierung und über 50 Jahre Erfahrung in der Baugruppenfertigung ermöglichen es uns, das einzige Unternehmen zu sein, das DIN 58145:2018-01 zertifizierte UV-Fasern mit geringer Solarisation und Baugruppen für den Spektralbereich von 185 nm bis 340 nm anbietet. Dies ermöglicht unseren OEM-Partnern, Wiederholbarkeit und Genauigkeit von einem System zum nächsten zu erzielen. Die Verwendung unserer qualifizierten Glasfasern überwindet die inhärente Schwäche einer Standard-Glasfaser und bietet Vorteile für Entwickler optischer Systeme. Kontaktieren Sie uns und sprechen Sie mit unserem erfahrenen optischen Ingenieurteam über die Integration qualifizierter Fasern in Ihre Designs.\u003c\/p\u003e\r\n\r\n\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"400 µm Kern | 25 cm","offer_id":42266451771482,"sku":"505155","price":250.0,"currency_code":"USD","in_stock":true},{"title":"400 µm Kern | 1 m","offer_id":42266451804250,"sku":"505156","price":510.0,"currency_code":"USD","in_stock":true},{"title":"600 µm Kern | 25 cm","offer_id":42266451837018,"sku":"505157","price":310.0,"currency_code":"USD","in_stock":true},{"title":"600 µm Kern | 1 m","offer_id":42266451869786,"sku":"505158","price":510.0,"currency_code":"USD","in_stock":true},{"title":"200 µm Kern","offer_id":42266451902554,"sku":"505163","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/img_4303_a81f7c4f-478e-4d58-a952-3595f66be53a.jpg?v=1766405784"},{"product_id":"var-505159-qualified-uv-nir","title":"Qualifiziert UV-NIR","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eEigenschaften\u003c\/h2\u003e\n\u003cp\u003eQVLUXNIR-Serie \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFasermaterial: Hochwertiges Siliziumdioxid\/Siliziumdioxid-Stufenindex Multimode\u003c\/li\u003e\n\u003cli\u003eKerngröße: 200µm, 400µm oder 600µm\u003c\/li\u003e\n\u003cli\u003eWellenlänge: UV-NIR 260-2200nm\u003c\/li\u003e\n\u003cli\u003eNumerische Apertur (NA): 0,22\u003c\/li\u003e\n\u003cli\u003eAnschluss: SMA 905, FC, ST, DIN, F125, F250, LLG\u003c\/li\u003e\n\u003cli\u003eMantel: Silikon-Monocoil-Schlauch\u003c\/li\u003e\n\u003cli\u003eTemperaturbereich -40°C bis 120°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eUV-verbesserte Breitband-Glasfaser 260-2200nm\u003c\/h2\u003e\n\u003cp\u003eWPIs \u003cstrong\u003eQVLUXNIR\u003c\/strong\u003e ist eine UV-verbesserte Breitbandfaser 260-2200nm \u003c\/p\u003e\n\u003ch2\u003eQVLUXNIR 1x1 Qualifizierte optische Faserkabeloptionen\u003c\/h2\u003e\n\u003ch2\u003eOptionen\u003c\/h2\u003e\n\u003ctable class=\"product-table\" style=\"width: 829px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 87px;\"\u003e\u003cstrong\u003eBestellcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003e\u003cstrong\u003eKatalog-Teilenummer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 503px;\"\u003e\u003cstrong\u003eBeschreibung\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 87px;\"\u003e\u003cstrong\u003eKerndurchmesser\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 87px;\"\u003e505159\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003eQVLUXNIR-S-0200-100-SMA\u003c\/td\u003e\n\u003ctd style=\"width: 503px;\"\u003e100cm qualifizierte Siliziumdioxidfaser mit 200µm Kerndurchmesser (260-2200nm). Geringe Solarisation bei 248nm\u003c\/td\u003e\n\u003ctd style=\"width: 87px;\"\u003e200 µm Kern\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 87px;\"\u003e505160\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003eQVLUXNIR-S-0400-100-SMA\u003c\/td\u003e\n\u003ctd style=\"width: 503px;\"\u003e\n\u003cp\u003e100cm qualifizierte Siliziumdioxidfaser mit 400µm Kerndurchmesser (260-2200nm). Geringe Solarisation bei 248nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 87px;\"\u003e400 µm Kern\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 87px;\"\u003e505161\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003eQVLUXNIR-S-0600-100-SMA\u003c\/td\u003e\n\u003ctd style=\"width: 503px;\"\u003e100cm qualifizierte Siliziumdioxidfaser mit 600µm Kerndurchmesser (260-2200nm). Geringe Solarisation bei 248nm\u003c\/td\u003e\n\u003ctd style=\"width: 87px;\"\u003e600 µm Kern\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\n\u003cspan style=\"font-size: 1.5em;\"\u003e\u003cbr\u003e\u003c\/span\u003eVorteile\u003c\/h2\u003e\n\u003ch2\u003eGabel-, Kreuz-, Mischfaser-Patchkabel, gebaut für Ihr spezifisches Projekt, Kontakt wpi@wpiinc.com \u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eQualifizierte proprietäre Faser ist WPIs fortschrittlichste Faserproduktlinie. DIN 58145:2017-01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQualifizierte Faser ermöglicht exzellente Übertragung von UV-NIR-Licht in langem Faserlänge und zeigt außergewöhnliche Leistung im Wellenlängenbereich 700-2200nm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWidersteht UV-bedingter Degradation besser als nahezu jede andere Faser auf dem Markt\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eErmöglicht einen echten „Plug-and-Play“-Austausch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIdeal für OEM und Anwendungen, die Außendienst erfordern oder bei denen mehrere Instrumente für eine Reihe von Tests verwendet werden müssen\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnthält Zertifikat und Daten sowohl zur UV-Transmission als auch zum induzierten Verlust, der durch kontinuierliche Belichtung mit einer 30W-Deuteriumlampe für jede Faser-Materialcharge von 185-360nm erzeugt wird\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAnwendungen\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFlüssigkeitschromatographie \u003c\/li\u003e\n\u003cli\u003eForensische Medizin\u003c\/li\u003e\n\u003cli\u003eUV-Raman \u003c\/li\u003e\n\u003cli\u003eMedizin\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/view.publitas.com\/world-precision-instruments\/2019-main-catalog\/page\/165\"\u003ehttps:\/\/view.publitas.com\/world-precision-instruments\/2019-main-catalog\/page\/165\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/de\/qualifiedfo\"\u003e\/qualifiedfo\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003ch2\u003eVideo\u003c\/h2\u003e\r\n\u003cp\u003eWPI Photonik-Kompetenzzentrum Array optischer Produkte\u003c\/p\u003e\r\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/YjXWnOc2faM?rel=0\" width=\"747\" height=\"420\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003eWPI Optische Fasern Lösungen für Forscher und Produktentwickler\u003c\/p\u003e\r\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/pesp2ugr4Bc?rel=0\" width=\"747\" height=\"420\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:specifications --\u003e\n\u003ch2\u003eQVLUXNIR STANDARDSPEZIFIKATIONEN\u003c\/h2\u003e\r\n\u003cp\u003eUnsere QVLUX-Faser wurde so entwickelt, dass sie nicht nur eine überlegene Übertragung im UV-Bereich bietet, sondern auch eine hervorragende Konsistenz über die Länge aufweist. Dies macht QVLUX zur perfekten Wahl für kritische Messungen oder wenn „Plug-and-Play“-Fähigkeit ohne Neukalibrierung nach einem Faserbaugruppenwechsel erforderlich ist. Unsere QVLUX-Faser bietet überlegene Beständigkeit gegen Solarisation, die niedrigste Grunddämpfung bei 200 nm (\u0026lt;1 dB\/m) und die geringste Solarisation bei 214 nm auf dem Markt. WPI ist das einzige Unternehmen, das DIN 58145:2017-01 zertifizierte UV-Fasern mit geringer Solarisation und Baugruppen anbietet. \u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eFasermaterial: Hochwertiges qualifiziertes Siliziumdioxid \/ Siliziumdioxid-Stufenindex Multimode\u003c\/li\u003e\r\n\u003cli\u003eDIN 58145:2018-01\u003c\/li\u003e\r\n\u003cli\u003eVerfügbare Kerndurchmesser: 400 µm, 600 µm\u003c\/li\u003e\r\n\u003cli\u003eWellenlänge: High OH: DUV-VIS 180-1200 nm\u003c\/li\u003e\r\n\u003cli\u003eNumerische Apertur (NA): 0,22\u003c\/li\u003e\r\n\u003cli\u003eAnschluss: \u003cstrong\u003eSMA 905\u003c\/strong\u003e, FC, ST, DIN, F125 (1,25 mm Ferrule), F250 (2,50 mm Ferrule)\u003c\/li\u003e\r\n\u003cli\u003eMantel: Silikon-Monocoil-Schlauch, Edelstahl-Monocoil\u003c\/li\u003e\r\n\u003cli\u003eTemperaturbereich -40°C bis 120°C\u003c\/li\u003e\r\n\u003cli\u003eNiedrigste Dämpfung bei 180 nm \u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/Certificate2.png\" alt=\"UV-NIR Zertifikat\" width=\"786\" height=\"957\"\u003e\u003c\/p\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"400 µm Kern","offer_id":42266456588378,"sku":"505160","price":240.0,"currency_code":"USD","in_stock":true},{"title":"600 µm Kern","offer_id":42266456621146,"sku":"505161","price":250.0,"currency_code":"USD","in_stock":true},{"title":"200 µm Kern","offer_id":42266456653914,"sku":"505159","price":240.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/img_4303_1_4e95e862-1b7a-4459-801d-321bc3eaaf0b.jpg?v=1766406124"},{"product_id":"var-505171-sillica-uv-vis","title":"UV-verbesserte Glasfaserkabel","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eAllzweck UV-verbesserte Glasfaser für UV-VIS-Spektroskopie.  \u003c\/h2\u003e\n\u003ch2\u003eEigenschaften\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWLUXUVIS-Serie \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFasermaterial: Siliziumdioxid\u003c\/li\u003e\n\u003cli\u003eKerngröße: 100um, 200um, 300um, 400um, 600um, 800um, 1000um\u003c\/li\u003e\n\u003cli\u003eWellenlänge: UV-VIS 260-1200nm\u003c\/li\u003e\n\u003cli\u003eNumerische Apertur (NA): 0,22\u003c\/li\u003e\n\u003cli\u003eSteckverbinder: \u003cstrong\u003eSMA 905\u003c\/strong\u003e, FC, ST, DIN, F125, F250, LLG\u003c\/li\u003e\n\u003cli\u003eMantel: Silikon-Monocoil-Schlauch\u003c\/li\u003e\n\u003cli\u003eTemperaturbereich -40C-120C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAllzweck UV-verbesserte Glasfaser \u003c\/h2\u003e\n\u003cp\u003eDie \u003cstrong\u003eWVLUXUVIS\u003c\/strong\u003e-Serie von WPI ist eine vielseitige Faser für UV-VIS-Spektroskopie. \u003c\/p\u003e\n\u003ch2\u003eWVLUXUVIS-Serie Patchkabel: Verbesserte UV-Glasfaser-Optionen\u003c\/h2\u003e\n\u003ctable class=\"product-table\" style=\"width: 829px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003e\u003cstrong\u003eBestellcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 180px;\"\u003e\u003cstrong\u003eKatalog-Teilenummer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 427px;\"\u003e\u003cstrong\u003eBeschreibung \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 106px;\"\u003e\u003cstrong\u003eKerndurchmesser\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003e\n\u003cp\u003e505171\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 180px;\"\u003e\n\u003cp\u003eWVLUXUVIS-S-0100-100-SMA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 427px;\"\u003e\n\u003cp\u003eSiliziumdioxidfaser (260-1200nm), 1 m \u003cstrong\u003eLänge\u003c\/strong\u003e mit SMA 905 Steckverbindern   \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 106px;\"\u003e\n\u003cp\u003e100 μm \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003e\n\u003cp\u003e505172\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 180px;\"\u003e\n\u003cp\u003eWVLUXUVIS-S-0200-100-SMA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 427px;\"\u003e\n\u003cp\u003eSiliziumdioxidfaser (260-1200nm), 1 m \u003cstrong\u003eLänge\u003c\/strong\u003e mit SMA 905 Steckverbindern   \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 106px;\"\u003e200 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003e\n\u003cp\u003e505173\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 180px;\"\u003e\n\u003cp\u003eWVLUXUVIS-S-0300-100-SMA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 427px;\"\u003e\n\u003cp\u003eSiliziumdioxidfaser (260-1200nm), 1 m \u003cstrong\u003eLänge\u003c\/strong\u003e mit SMA 905 Steckverbindern   \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 106px;\"\u003e300 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003e505174\u003c\/td\u003e\n\u003ctd style=\"width: 180px;\"\u003eWVLUXUVIS-S-0400-100-SMA\u003c\/td\u003e\n\u003ctd style=\"width: 427px;\"\u003eSiliziumdioxidfaser (260-1200nm), 1 m \u003cstrong\u003eLänge\u003c\/strong\u003e mit SMA 905 Steckverbindern   \u003c\/td\u003e\n\u003ctd style=\"width: 106px;\"\u003e400 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003e505195\u003c\/td\u003e\n\u003ctd style=\"width: 180px;\"\u003eWVLUXUVIS-S-0600-100-SMA\u003c\/td\u003e\n\u003ctd style=\"width: 427px;\"\u003eSiliziumdioxidfaser (260-1200nm), 1 m \u003cstrong\u003eLänge\u003c\/strong\u003e mit SMA 905 Steckverbindern   \u003c\/td\u003e\n\u003ctd style=\"width: 106px;\"\u003e600 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eBifurkierte, Kreuz- und gemischte Faser-Patchkabel, gebaut für Ihr spezifisches Projekt, Kontakt wpi@wpiinc.com \u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:specifications --\u003e\n\u003cp\u003e\u003cstrong\u003eWLUXUVIS-Serie \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFasermaterial: Siliziumdioxid\u003c\/li\u003e\n\u003cli\u003eKerngröße: 100um, 200um, 300um, 400um, 600um, 800um, 1000um\u003c\/li\u003e\n\u003cli\u003eWellenlänge: UV-VIS 260-1200nm\u003c\/li\u003e\n\u003cli\u003eNumerische Apertur (NA): 0,22\u003c\/li\u003e\n\u003cli\u003eStecker: \u003cb\u003eSMA 905\u003c\/b\u003e, FC, ST, DIN, F125, F250, LLG, N\u003c\/li\u003e\n\u003cli\u003eMantel: Silikon-Monocoil-Schlauch\u003c\/li\u003e\n\u003cli\u003eTemperaturbereich -40C-120C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:specifications --\u003e","brand":"World Precision Instruments","offers":[{"title":"100 µm Kern","offer_id":42266457014362,"sku":"505171","price":180.0,"currency_code":"USD","in_stock":true},{"title":"200 µm Kern","offer_id":42266457047130,"sku":"505172","price":180.0,"currency_code":"USD","in_stock":true},{"title":"300 µm Kern","offer_id":42266457079898,"sku":"505173","price":180.0,"currency_code":"USD","in_stock":true},{"title":"400 µm Kern","offer_id":42266457112666,"sku":"505174","price":180.0,"currency_code":"USD","in_stock":true},{"title":"600 µm Kern","offer_id":42266457145434,"sku":"505195","price":425.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/uv-enhanced_fiber_optic_cable_691f2707-624f-4046-b374-68b598fb4f0a.jpg?v=1766406151"}],"url":"https:\/\/wpiinc.com\/de\/collections\/optical-detectors-1.oembed","provider":"World Precision Instruments","version":"1.0","type":"link"}