{"title":"Neurotransmitter Detection","description":"\u003ch1\u003e\u003cspan\u003eElectrochemical Detection of Oxidizable Compounds\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003eCarbon fiber microelectrodes have been used in both the detection of oxidizable compounds (Gonon, et al., 1978; Cahill and Wightman, 1995) and extracellular single-unit recording (Armstrong-James and Millar, 1979). WPI's ultra-sensitive and low-noise carbon fiber (CF) electrodes can be applied, with our Micro-C Potentiostat or similar instruments, in the electrochemical detection of catecholamines (epinephrine, norepinephrine and dopamine), indolamines (serotonin, 5-HT or melatonin), Fe (II) and other oxidizable compounds.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/cf10-cf30.jpg\" alt=\"\" width=\"449\" height=\"449\"\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDiameter: 10 um\u003c\/li\u003e\n\u003cli\u003eLength: 100 um\u003c\/li\u003e\n\u003cli\u003ePack of 5\u003c\/li\u003e\n\u003cli\u003eUltra-sensitive and low noise\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/microcconccurve.jpg\" alt=\"\" width=\"512\" height=\"396\"\u003e\u003c\/p\u003e\n\u003cp\u003eFig. 1-Excellent linearity in response of carbon fiber electrode (\u003cstrong\u003eCF30-500\u003c\/strong\u003e) to dopamine recorded on a \u003cstrong\u003eMicroC\u003c\/strong\u003e. Courtesy: Drs. D Yeomans and X.-T. Wang, University of Illinis at Chicago.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eCF electrodes (diameter of 10 or 30 um) respond with an excellent linearity to the oxidizable compounds and can detect the compounds as low as 0.2 nM. The shorter (25-100 um) CF electrodes are suitable for in vivo amperometric and voltammetric measurements. When used with the \u003ca href=\"https:\/\/www.wpiinc.com\/sys-microc-carbon-fiber-potentiostat\"\u003e\u003cstrong\u003eMicroC \u003c\/strong\u003e\u003c\/a\u003ePotentiostat, these CF electrodes can be activated and renewed in sensitivity for multiple use. The selective detection of catecholamines can be achieved with our Nafion-coated CF electrodes. For selective detection of 5-HT, please contact WPI for more information.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/microcfig2.jpg\" alt=\"\" width=\"476\" height=\"308\"\u003e\u003cbr\u003eFig. 2-Extracellular recording using a carbon electrode in CA1 region of the hippocampus in an anesthetized rat shows ultra-low noise ( ≤5μV). Courtesy: Dr. Carolyn Harley of Memorial University, Newfoundland, Canada.\u003c\/p\u003e","products":[{"product_id":"cf10-100-carbon-fiber-electrode-l-100-um","title":"Carbon Fiber Electrode, L 100 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDiameter: 10 um\u003c\/li\u003e\r\n\u003cli\u003eLength: 100 um\u003c\/li\u003e\r\n\u003cli\u003ePack of 5\u003c\/li\u003e\r\n\u003cli\u003eUltra-sensitive and low noise\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_e3d4d5e4-04b7-4e0a-9a82-abcf269c1d97.jpg?v=1765945657\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eFig. 1-Excellent linearity in response of carbon fiber electrode (\u003ca href=\"\/cf30-500-carbon-fiber-electrode-length-500-um\"\u003e\u003cstrong\u003eCF30-500\u003c\/strong\u003e\u003c\/a\u003e) to dopamine recorded on a MicroC. Courtesy: Drs. D Yeomans and X.-T. Wang, University of Illinis at Chicago.\u003c\/p\u003e\r\n\u003ch2\u003eApplications\u003c\/h2\u003e\r\n\u003cp\u003eCF electrodes (diameter of 10 or 30 um) respond with an excellent linearity to the oxidizable compounds and can detect the compounds as low as 0.2 nM. The shorter (25-100 um) CF electrodes are suitable for in vivo amperometric and voltammetric measurements. When used with the MicroC Potentiostat, these CF electrodes can be activated and renewed in sensitivity for multiple use. The selective detection of catecholamines can be achieved with our Nafion-coated CF electrodes. For selective detection of 5-HT, please contact WPI for more information.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_08d43912-7321-4d82-a55c-4e79740271ea.jpg?v=1765945662\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Extracellular recording using a carbon electrode in CA1 region of the hippocampus in an anesthetized rat shows ultra-low noise ( ≤5μV). Courtesy: Dr. Carolyn Harley of Memorial University, Newfoundland, Canada.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eCF10\/CF30 Carbon Fiber Microelectrodes Instruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eM. Potie, F. Bedioui, J. Devnck\u003c\/strong\u003e \"New Composite Modified Carbon Microfibers for Sensitive and Selective Determination of Physiologically Relevant Concentrations of Nitric Oxide in Solution\" \u003cspan style=\"font-style: italic;\"\u003eElectroanalysis\u003c\/span\u003e 11. 1999: 845-850\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266095517786,"sku":"CF10-100","price":617.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_13_6dc25553-9da7-453c-bd19-4e375c1c32b5.jpg?v=1766396964"},{"product_id":"cf10-250-carbon-fiber-electrode-l-250-um","title":"Carbon Fiber Electrode, L 250 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDiameter: 10 um\u003c\/li\u003e\r\n\u003cli\u003eLength: 250 um\u003c\/li\u003e\r\n\u003cli\u003ePack of 5\u003c\/li\u003e\r\n\u003cli\u003eUltra-sensitive and low noise\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_a62d9011-5ee7-4d22-ac3d-cd8f685aad28.jpg?v=1765945674\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eFig. 1-Excellent linearity in response of carbon fiber electrode (CF30-500) to dopamine recorded on a MicroC. Courtesy: Drs. D Yeomans and X.-T. Wang, University of Illinis at Chicago.\u003c\/p\u003e\r\n\u003ch2\u003eApplications\u003c\/h2\u003e\r\n\u003cp\u003eCF electrodes (diameter of 10 or 30 um) respond with an excellent linearity to the oxidizable compounds and can detect the compounds as low as 0.2 nM. The shorter (25-100 um) CF electrodes are suitable for in vivo amperometric and voltammetric measurements. When used with the MicroC Potentiostat, these CF electrodes can be activated and renewed in sensitivity for multiple use. The selective detection of catecholamines can be achieved with our Nafion-coated CF electrodes. For selective detection of 5-HT, please contact WPI for more information.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_03016fe5-f950-405f-9e35-96e577b46c44.jpg?v=1765945680\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Extracellular recording using a carbon electrode in CA1 region of the hippocampus in an anesthetized rat shows ultra-low noise ( ≤5μV). Courtesy: Dr. Carolyn Harley of Memorial University, Newfoundland, Canada.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eCF10\/CF30 Carbon Fiber Microelectrodes Instruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eM. Potie, F. Bedioui, J. Devnck\u003c\/strong\u003e \"New Composite Modified Carbon Microfibers for Sensitive and Selective Determination of Physiologically Relevant Concentrations of Nitric Oxide in Solution\" \u003cspan style=\"font-style: italic;\"\u003eElectroanalysis\u003c\/span\u003e 11. 1999: 845-850\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266096369754,"sku":"CF10-250","price":617.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_3_03b153a2-dca5-4fa6-bf3d-813a73264d68.jpg?v=1766396975"},{"product_id":"cf10-500-carbon-fiber-electrode-l-500-um","title":"Carbon Fiber Electrode, L 500 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDiameter: 10 um\u003c\/li\u003e\r\n\u003cli\u003eLength: 500 um\u003c\/li\u003e\r\n\u003cli\u003ePack of 5\u003c\/li\u003e\r\n\u003cli\u003eUltra-sensitive and low noise\u003c\/li\u003e\r\n\u003cli\u003eBuilt to order. Please allow up to four weeks manufacturing time.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_7fa4e40e-da05-4595-b4c9-a60899b7eb38.jpg?v=1765945689\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eFig. 1-Excellent linearity in response of carbon fiber electrode (CF30-500) to dopamine recorded on a MicroC. Courtesy: Drs. D Yeomans and X.-T. Wang, University of Illinis at Chicago.\u003c\/p\u003e\r\n\u003ch2\u003eApplications\u003c\/h2\u003e\r\n\u003cp\u003eCF electrodes (diameter of 10 or 30 um) respond with an excellent linearity to the oxidizable compounds and can detect the compounds as low as 0.2 nM. The shorter (25-100 um) CF electrodes are suitable for in vivo amperometric and voltammetric measurements. When used with the MicroC Potentiostat, these CF electrodes can be activated and renewed in sensitivity for multiple use. The selective detection of catecholamines can be achieved with our Nafion-coated CF electrodes. For selective detection of 5-HT, please contact WPI for more information.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_d3b273d0-5cf0-4289-82ba-bf02e9b29850.jpg?v=1765945695\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Extracellular recording using a carbon electrode in CA1 region of the hippocampus in an anesthetized rat shows ultra-low noise ( ≤5μV). Courtesy: Dr. Carolyn Harley of Memorial University, Newfoundland, Canada.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eCF10\/CF30 Carbon Fiber Microelectrodes Instruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eM. Potie, F. Bedioui, J. Devnck\u003c\/strong\u003e \"New Composite Modified Carbon Microfibers for Sensitive and Selective Determination of Physiologically Relevant Concentrations of Nitric Oxide in Solution\" \u003cspan style=\"font-style: italic;\"\u003eElectroanalysis\u003c\/span\u003e 11. 1999: 845-850\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266097483866,"sku":"CF10-500","price":780.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_109e2aec-57ce-4b50-bd48-34b1a8060cd0.jpg?v=1766396983"},{"product_id":"cf30-100-carbon-fiber-electrode-length-100-um","title":"Carbon Fiber Electrode, Length 100 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDiameter: 30 um\u003c\/li\u003e\r\n\u003cli\u003eLength: 100 um\u003c\/li\u003e\r\n\u003cli\u003ePack of 5\u003c\/li\u003e\r\n\u003cli\u003eUltra-sensitive and low noise\u003c\/li\u003e\r\n\u003cli\u003eBuilt to order. Please allow up to four weeks manufacturing time.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_7222799f-5226-4f27-b10d-aadd2e6bcb15.jpg?v=1765945705\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eFig. 1-Excellent linearity in response of carbon fiber electrode (CF30-500) to dopamine recorded on a MicroC. Courtesy: Drs. D Yeomans and X.-T. Wang, University of Illinis at Chicago.\u003c\/p\u003e\r\n\u003ch2\u003eApplications\u003c\/h2\u003e\r\n\u003cp\u003eCF electrodes (diameter of 10 or 30 um) respond with an excellent linearity to the oxidizable compounds and can detect the compounds as low as 0.2 nM. The shorter (25-100 um) CF electrodes are suitable for in vivo amperometric and voltammetric measurements. When used with the Micro-C Potentiostat, these CF electrodes can be activated and renewed in sensitivity for multiple use. The selective detection of catecholamines can be achieved with our Nafion-coated CF electrodes. For selective detection of 5-HT, please contact WPI for more information.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_bd13e8e1-b97a-4af5-85df-8488e1f47880.jpg?v=1765945710\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Extracellular recording using a carbon electrode in CA1 region of the hippocampus in an anesthetized rat shows ultra-low noise ( ≤5μV). Courtesy: Dr. Carolyn Harley of Memorial University, Newfoundland, Canada.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eCF10\/CF30 Carbon Fiber Microelectrodes Instruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eM. Potie, F. Bedioui, J. Devnck\u003c\/strong\u003e \"New Composite Modified Carbon Microfibers for Sensitive and Selective Determination of Physiologically Relevant Concentrations of Nitric Oxide in Solution\" \u003cspan style=\"font-style: italic;\"\u003eElectroanalysis\u003c\/span\u003e 11. 1999: 845-850\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266098499674,"sku":"CF30-100","price":598.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_1_c934e29a-3f49-44c9-9c98-48c75a973015.jpg?v=1766396991"},{"product_id":"cf30-1000-carbon-fiber-electrode-length-1000-um","title":"Carbon Fiber Electrode, Length 1000 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDiameter: 30 um\u003c\/li\u003e\r\n\u003cli\u003eLength: 1000 um\u003c\/li\u003e\r\n\u003cli\u003ePack of 5\u003c\/li\u003e\r\n\u003cli\u003eUltra-sensitive and low noise\u003c\/li\u003e\r\n\u003cli\u003eBuilt to order. Please allow up to four weeks manufacturing time.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_96d2d802-7130-4baf-b6f1-5f6c98d4868a.jpg?v=1765945720\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eFig. 1-Excellent linearity in response of carbon fiber electrode (CF30-500) to dopamine recorded on a MicroC. Courtesy: Drs. D Yeomans and X.-T. Wang, University of Illinis at Chicago.\u003c\/p\u003e\r\n\u003ch2\u003eApplications\u003c\/h2\u003e\r\n\u003cp\u003eCF electrodes (diameter of 10 or 30 um) respond with an excellent linearity to the oxidizable compounds and can detect the compounds as low as 0.2 nM. The shorter (25-100 um) CF electrodes are suitable for in vivo amperometric and voltammetric measurements. When used with the Micro-C Potentiostat, these CF electrodes can be activated and renewed in sensitivity for multiple use. The selective detection of catecholamines can be achieved with our Nafion-coated CF electrodes. For selective detection of 5-HT, please contact WPI for more information.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_6ce96aca-d329-41da-9795-88e26b78eccc.jpg?v=1765945726\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Extracellular recording using a carbon electrode in CA1 region of the hippocampus in an anesthetized rat shows ultra-low noise ( ≤5μV). Courtesy: Dr. Carolyn Harley of Memorial University, Newfoundland, Canada.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eCF10\/CF30 Carbon Fiber Microelectrodes Instruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eM. Potie, F. Bedioui, J. Devnck\u003c\/strong\u003e \"New Composite Modified Carbon Microfibers for Sensitive and Selective Determination of Physiologically Relevant Concentrations of Nitric Oxide in Solution\" \u003cspan style=\"font-style: italic;\"\u003eElectroanalysis\u003c\/span\u003e 11. 1999: 845-850\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266099155034,"sku":"CF30-1000","price":638.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_2_80999054-e9c4-4f7e-be7c-c4aa15144496.jpg?v=1766396999"},{"product_id":"cf30-50-carbon-fiber-electrode-length-50-um","title":"Carbon Fiber Electrode, Length 50 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDiameter: 30 um\u003c\/li\u003e\r\n\u003cli\u003eLength: 50 um\u003c\/li\u003e\r\n\u003cli\u003ePack of 5\u003c\/li\u003e\r\n\u003cli\u003eUltra-sensitive and low noise\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_f4197b9a-8055-4903-8e3a-b0a74aa8513d.jpg?v=1765945738\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eFig. 1-Excellent linearity in response of carbon fiber electrode (CF30-500) to dopamine recorded on a MicroC. Courtesy: Drs. D Yeomans and X.-T. Wang, University of Illinis at Chicago.\u003c\/p\u003e\r\n\u003ch2\u003eApplications\u003c\/h2\u003e\r\n\u003cp\u003eCF electrodes (diameter of 10 or 30 um) respond with an excellent linearity to the oxidizable compounds and can detect the compounds as low as 0.2 nM. The shorter (25-100 um) CF electrodes are suitable for in vivo amperometric and voltammetric measurements. When used with the Micro-C Potentiostat, these CF electrodes can be activated and renewed in sensitivity for multiple use. The selective detection of catecholamines can be achieved with our Nafion-coated CF electrodes. For selective detection of 5-HT, please contact WPI for more information.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_11f44941-36cb-40c3-b1d9-0abef6fd5ac9.jpg?v=1765945744\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Extracellular recording using a carbon electrode in CA1 region of the hippocampus in an anesthetized rat shows ultra-low noise ( ≤5μV). Courtesy: Dr. Carolyn Harley of Memorial University, Newfoundland, Canada.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eCF10\/CF30 Carbon Fiber Microelectrodes Instruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eM. Potie, F. Bedioui, J. Devnck\u003c\/strong\u003e \"New Composite Modified Carbon Microfibers for Sensitive and Selective Determination of Physiologically Relevant Concentrations of Nitric Oxide in Solution\" \u003cspan style=\"font-style: italic;\"\u003eElectroanalysis\u003c\/span\u003e 11. 1999: 845-850\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266100269146,"sku":"CF30-50","price":587.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_7_479d5ce6-8774-471c-85e4-f414a9ea01fb.jpg?v=1766397010"},{"product_id":"cf30-500-carbon-fiber-electrode-length-500-um","title":"Carbon Fiber Electrode, Length 500 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDiameter: 30 um\u003c\/li\u003e\r\n\u003cli\u003eLength: 500 um\u003c\/li\u003e\r\n\u003cli\u003ePack of 5\u003c\/li\u003e\r\n\u003cli\u003eUltra-sensitive and low noise\u003c\/li\u003e\r\n\u003cli\u003eBuilt to order. Please allow up to four weeks manufacturing time.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_2606cfc9-9a97-4771-a2ff-557464cfd0cd.jpg?v=1765945753\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eFig. 1-Excellent linearity in response of carbon fiber electrode (CF30-500) to dopamine recorded on a MicroC. Courtesy: Drs. D Yeomans and X.-T. Wang, University of Illinis at Chicago.\u003c\/p\u003e\r\n\u003ch2\u003eApplications\u003c\/h2\u003e\r\n\u003cp\u003eCF electrodes (diameter of 10 or 30 um) respond with an excellent linearity to the oxidizable compounds and can detect the compounds as low as 0.2 nM. The shorter (25-100 um) CF electrodes are suitable for in vivo amperometric and voltammetric measurements. When used with the Micro-C Potentiostat, these CF electrodes can be activated and renewed in sensitivity for multiple use. The selective detection of catecholamines can be achieved with our Nafion-coated CF electrodes. For selective detection of 5-HT, please contact WPI for more information.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_1f081c2f-c571-4d63-a4e7-9a148d3b596a.jpg?v=1765945759\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Extracellular recording using a carbon electrode in CA1 region of the hippocampus in an anesthetized rat shows ultra-low noise ( ≤5μV). Courtesy: Dr. Carolyn Harley of Memorial University, Newfoundland, Canada.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eCF10\/CF30 Carbon Fiber Microelectrodes Instruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eM. Potie, F. Bedioui, J. Devnck\u003c\/strong\u003e \"New Composite Modified Carbon Microfibers for Sensitive and Selective Determination of Physiologically Relevant Concentrations of Nitric Oxide in Solution\" \u003cspan style=\"font-style: italic;\"\u003eElectroanalysis\u003c\/span\u003e 11. 1999: 845-850\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266101186650,"sku":"CF30-500","price":975.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_12_8618a2d2-20a1-4070-a422-0a61852f0fb1.jpg?v=1766397018"},{"product_id":"cfn10-100-carbon-fiber-electrode-dia-10-um-length-100-um","title":"Carbon Fiber Electrode, Dia 10 um, Length 100 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDiameter: 10 um\u003c\/li\u003e\r\n\u003cli\u003eLength: 100 um\u003c\/li\u003e\r\n\u003cli\u003ePack of 5\u003c\/li\u003e\r\n\u003cli\u003eUltra-sensitive and low noise\u003c\/li\u003e\r\n\u003cli\u003eNafion-coated\u003c\/li\u003e\r\n\u003cli\u003eBuilt to order. Please allow up to four weeks manufacturing time.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_bf1615fd-6116-46a7-a977-6d02a787220a.jpg?v=1765945768\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eFig. 1-Excellent linearity in response of carbon fiber electrode (CF30-500) to dopamine recorded on a MicroC. Courtesy: Drs. D Yeomans and X.-T. Wang, University of Illinis at Chicago.\u003c\/p\u003e\r\n\u003ch2\u003eApplications\u003c\/h2\u003e\r\n\u003cp\u003eCF electrodes (diameter of 10 or 30 um) respond with an excellent linearity to the oxidizable compounds and can detect the compounds as low as 0.2 nM. The shorter (25-100 um) CF electrodes are suitable for \u003cem\u003ein vivo\u003c\/em\u003e amperometric and voltammetric measurements. When used with the MicroC Potentiostat, these CF electrodes can be activated and renewed in sensitivity for multiple use. The selective detection of catecholamines can be achieved with our Nafion-coated CF electrodes. For selective detection of 5-HT, please contact WPI for more information.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_3925ceaa-8c2d-4ed3-acd2-e1c45613628f.jpg?v=1765945774\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Extracellular recording using a carbon electrode in CA1 region of the hippocampus in an anesthetized rat shows ultra-low noise ( ≤5μV). Courtesy: Dr. Carolyn Harley of Memorial University, Newfoundland, Canada.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eCF10\/CF30 Carbon Fiber Microelectrodes Instruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eL. Yavich, P. Jkl, H.Tanila\u003c\/strong\u003e \"Noradrenaline overflow in mouse dentate gyrus following locus coeruleus and natural stimulation: real-time monitoring by in vivo voltammetry\" \u003cspan style=\"font-style: italic;\"\u003eJ of Neurochemistry\u003c\/span\u003e 95. 2005: 641-650\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266101874778,"sku":"CFN10-100","price":748.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_6_11380561-fad5-40c0-af6e-cac2cff52198.jpg?v=1766397026"},{"product_id":"cfn10-250-carbon-fiber-electrode-dia-10-umlength-250-um","title":"Carbon Fiber Electrode, Dia 10 um,Length 250 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDiameter: 10 um\u003c\/li\u003e\r\n\u003cli\u003eLength: 250 um\u003c\/li\u003e\r\n\u003cli\u003ePack of 5\u003c\/li\u003e\r\n\u003cli\u003eUltra-sensitive and low noise\u003c\/li\u003e\r\n\u003cli\u003eNafion-coated\u003c\/li\u003e\r\n\u003cli\u003eBuilt to order. Please allow up to four weeks manufacturing time.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_bd96a5a8-5ce8-4a2b-a6d5-fa02f36ea82f.jpg?v=1765945784\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eFig. 1-Excellent linearity in response of carbon fiber electrode (CF30-500) to dopamine recorded on a MicroC. Courtesy: Drs. D Yeomans and X.-T. Wang, University of Illinis at Chicago.\u003c\/p\u003e\r\n\u003ch2\u003eApplications\u003c\/h2\u003e\r\n\u003cp\u003eCF electrodes (diameter of 10 or 30 um) respond with an excellent linearity to the oxidizable compounds and can detect the compounds as low as 0.2 nM. The shorter (25-100 um) CF electrodes are suitable for in vivo amperometric and voltammetric measurements. When used with the MicroC Potentiostat, these CF electrodes can be activated and renewed in sensitivity for multiple use. The selective detection of catecholamines can be achieved with our Nafion-coated CF electrodes. For selective detection of 5-HT, please contact WPI for more information.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_e5dcc476-258f-4c0a-b6a7-83acfa4117d7.jpg?v=1765945789\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Extracellular recording using a carbon electrode in CA1 region of the hippocampus in an anesthetized rat shows ultra-low noise ( ≤5μV). Courtesy: Dr. Carolyn Harley of Memorial University, Newfoundland, Canada.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eCF10\/CF30 Carbon Fiber Microelectrodes Instruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eL. Yavich, P. Jkl, H.Tanila\u003c\/strong\u003e \"Noradrenaline overflow in mouse dentate gyrus following locus coeruleus and natural stimulation: real-time monitoring by in vivo voltammetry\" \u003cspan style=\"font-style: italic;\"\u003eJ of Neurochemistry\u003c\/span\u003e 95. 2005: 641-650\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266102300762,"sku":"CFN10-250","price":651.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_10_7cae82b9-3dd0-48d3-b487-5c942380292c.jpg?v=1766397034"},{"product_id":"cfn10-50-carbon-fiber-electrode-dia-10-um-length-50-um","title":"Carbon Fiber Electrode, Dia 10 um, Length 50 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDiameter: 10 um\u003c\/li\u003e\r\n\u003cli\u003eLength: 50 um\u003c\/li\u003e\r\n\u003cli\u003ePack of 5\u003c\/li\u003e\r\n\u003cli\u003eUltra-sensitive and low noise\u003c\/li\u003e\r\n\u003cli\u003eNafion-coated\u003c\/li\u003e\r\n\u003cli\u003eBuilt to order. Please allow up to four weeks manufacturing time.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_038340f4-8365-4143-8152-caf723d75371.jpg?v=1765945802\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eFig. 1-Excellent linearity in response of carbon fiber electrode (CF30-500) to dopamine recorded on a MicroC. Courtesy: Drs. D Yeomans and X.-T. Wang, University of Illinis at Chicago.\u003c\/p\u003e\r\n\u003ch2\u003eApplications\u003c\/h2\u003e\r\n\u003cp\u003eCF electrodes (diameter of 10 or 30 um) respond with an excellent linearity to the oxidizable compounds and can detect the compounds as low as 0.2 nM. The shorter (25-100 um) CF electrodes are suitable for in vivo amperometric and voltammetric measurements. When used with the MicroC Potentiostat, these CF electrodes can be activated and renewed in sensitivity for multiple use. The selective detection of catecholamines can be achieved with our Nafion-coated CF electrodes. For selective detection of 5-HT, please contact WPI for more information.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_c526317b-4231-46bd-9d2a-01db8d76437c.jpg?v=1765945808\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Extracellular recording using a carbon electrode in CA1 region of the hippocampus in an anesthetized rat shows ultra-low noise ( ≤5μV). Courtesy: Dr. Carolyn Harley of Memorial University, Newfoundland, Canada.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eCF10\/CF30 Carbon Fiber Microelectrodes Instruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eL. Yavich, P. Jkl, H.Tanila\u003c\/strong\u003e \"Noradrenaline overflow in mouse dentate gyrus following locus coeruleus and natural stimulation: real-time monitoring by in vivo voltammetry\" \u003cspan style=\"font-style: italic;\"\u003eJ of Neurochemistry\u003c\/span\u003e 95. 2005: 641-650\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266102530138,"sku":"CFN10-50","price":840.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_5_46877531-dffa-4171-9f12-1e053236a2aa.jpg?v=1766397045"},{"product_id":"cfn30-100-carbon-fiber-electrode-dia-30-um-l-100-um","title":"Carbon Fiber Electrode, Dia 30 um, L 100 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDiameter: 30 um\u003c\/li\u003e\r\n\u003cli\u003eLength: 100 um\u003c\/li\u003e\r\n\u003cli\u003ePack of 5\u003c\/li\u003e\r\n\u003cli\u003eUltra-sensitive and low noise\u003c\/li\u003e\r\n\u003cli\u003eNafion-coated\u003c\/li\u003e\r\n\u003cli\u003eBuilt to order. Please allow up to four weeks manufacturing time.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eApplications\u003c\/h2\u003e\r\n\u003cp\u003eCF electrodes (diameter of 10 or 30 um) respond with an excellent linearity to the oxidizable compounds and can detect the compounds as low as 0.2 nM. The shorter (25-100 um) CF electrodes are suitable for in vivo amperometric and voltammetric measurements. When used with the Micro-C Potentiostat, these CF electrodes can be activated and renewed in sensitivity for multiple use. The selective detection of catecholamines can be achieved with our Nafion-coated CF electrodes. For selective detection of 5-HT, please contact WPI for more information.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eL. Yavich, P. JkI, H.Tanila\u003c\/strong\u003e \"Noradrenaline overflow in mouse dentate gyrus following locus coeruleus and natural stimulation: real-time monitoring by in vivo voltammetry\" \u003cspan style=\"font-style: italic;\"\u003eJ of Neurochemistry\u003c\/span\u003e 95. 2005: 641-650\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266103119962,"sku":"CFN30-100","price":617.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_9_3d629af9-4e18-4ae9-866b-d47e41bfbfd5.jpg?v=1766397053"},{"product_id":"cfn30-1000-carbon-fiber-electrode-dia-30-um-l-1000-um","title":"Carbon Fiber Electrode, Dia 30 um, L 1000 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDiameter: 30 um\u003c\/li\u003e\r\n\u003cli\u003eLength: 1000 um\u003c\/li\u003e\r\n\u003cli\u003ePack of 5\u003c\/li\u003e\r\n\u003cli\u003eUltra-sensitive and low noise\u003c\/li\u003e\r\n\u003cli\u003eNafion-coated\u003c\/li\u003e\r\n\u003cli\u003eBuilt to order. Please allow up to four weeks manufacturing time.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_0c25b942-91cb-402f-9a50-2a8b99e7848a.jpg?v=1765945821\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\r\n\u003cp\u003eFig. 1-Excellent linearity in response of carbon fiber electrode (CF30-500) to dopamine recorded on a MicroC. Courtesy: Drs. D Yeomans and X.-T. Wang, University of Illinis at Chicago.\u003c\/p\u003e\r\n\u003ch2\u003eApplications\u003c\/h2\u003e\r\n\u003cp\u003eCF electrodes (diameter of 10 or 30 um) respond with an excellent linearity to the oxidizable compounds and can detect the compounds as low as 0.2 nM. The shorter (25-100 um) CF electrodes are suitable for in vivo amperometric and voltammetric measurements. When used with the Micro-C Potentiostat, these CF electrodes can be activated and renewed in sensitivity for multiple use. The selective detection of catecholamines can be achieved with our Nafion-coated CF electrodes. For selective detection of 5-HT, please contact WPI for more information.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_6e67a66f-81b2-422e-a695-32c306456a3b.jpg?v=1765945827\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Extracellular recording using a carbon electrode in CA1 region of the hippocampus in an anesthetized rat shows ultra-low noise ( ≤5μV). Courtesy: Dr. Carolyn Harley of Memorial University, Newfoundland, Canada.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eCF10\/CF30 Carbon Fiber Microelectrodes Instruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eL. Yavich, P. Jkl, H.Tanila\u003c\/strong\u003e \"Noradrenaline overflow in mouse dentate gyrus following locus coeruleus and natural stimulation: real-time monitoring by in vivo voltammetry\" \u003cspan style=\"font-style: italic;\"\u003eJ of Neurochemistry\u003c\/span\u003e 95. 2005: 641-650\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266103382106,"sku":"CFN30-1000","price":617.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_4_daa8afce-7804-485b-a927-db1bb35c794d.jpg?v=1766397062"},{"product_id":"cfn30-250-carbon-fiber-electrode-dia-30-um-l-250-um","title":"Carbon Fiber Electrode, Dia 30 um, L 250 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDiameter: 30 um\u003c\/li\u003e\n\u003cli\u003eLength: 250 um\u003c\/li\u003e\n\u003cli\u003ePack of 5\u003c\/li\u003e\n\u003cli\u003eUltra-sensitive and low noise\u003c\/li\u003e\n\u003cli\u003eNafion-coated\u003c\/li\u003e\n\u003cli\u003eBuilt to order. Please allow up to four weeks manufacturing time.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_cda34e48-3c5c-46f2-a0c7-b2aa8528eb36.jpg?v=1765945836\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\n\u003cp\u003eFig. 1-Excellent linearity in response of carbon fiber electrode (CF30-500) to dopamine recorded on a MicroC. Courtesy: Drs. D Yeomans and X.-T. Wang, University of Illinis at Chicago.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eCF electrodes (diameter of 10 or 30 um) respond with an excellent linearity to the oxidizable compounds and can detect the compounds as low as 0.2 nM. The shorter (25-100 um) CF electrodes are suitable for in vivo amperometric and voltammetric measurements. When used with the Micro-C Potentiostat, these CF electrodes can be activated and renewed in sensitivity for multiple use. The selective detection of catecholamines can be achieved with our Nafion-coated CF electrodes. For selective detection of 5-HT, please contact WPI for more information.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_a014042c-2133-4ae0-bcee-e87261c43e92.jpg?v=1765945842\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Extracellular recording using a carbon electrode in CA1 region of the hippocampus in an anesthetized rat shows ultra-low noise ( ≤5μV). Courtesy: Dr. Carolyn Harley of Memorial University, Newfoundland, Canada.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eCF10\/CF30 Carbon Fiber Microelectrodes Instruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eL. Yavich, P. Jkl, H.Tanila\u003c\/strong\u003e \"Noradrenaline overflow in mouse dentate gyrus following locus coeruleus and natural stimulation: real-time monitoring by in vivo voltammetry\" \u003cspan style=\"font-style: italic;\"\u003eJ of Neurochemistry\u003c\/span\u003e 95. 2005: 641-650\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266105282650,"sku":"CFN30-250","price":617.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_11_1000985c-878d-4e91-9ee2-4e8b65ca9369.jpg?v=1766397069"},{"product_id":"cfn30-50-carbon-fiber-electrode-dia-30-um-l-50-um","title":"Carbon Fiber Electrode, Dia 30 um, L 50 um","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDiameter: 30 um\u003c\/li\u003e\n\u003cli\u003eLength: 50 um\u003c\/li\u003e\n\u003cli\u003ePack of 5\u003c\/li\u003e\n\u003cli\u003eUltra-sensitive and low noise\u003c\/li\u003e\n\u003cli\u003eNafion-coated\u003c\/li\u003e\n\u003cli\u003eBuilt to order. Please allow up to four weeks manufacturing time.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg style=\"margin: 5px;\" title=\"microcconccurve.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcconccurve_a4a365ca-0c0b-43d1-aa07-62026b957e1a.jpg?v=1765945854\" alt=\"microcconccurve.jpg\" width=\"403\" height=\"311\"\u003e\u003c\/p\u003e\n\u003cp\u003eFig. 1-Excellent linearity in response of carbon fiber electrode (CF30-500) to dopamine recorded on a MicroC. Courtesy: Drs. D Yeomans and X.-T. Wang, University of Illinis at Chicago.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eCF electrodes (diameter of 10 or 30 um) respond with an excellent linearity to the oxidizable compounds and can detect the compounds as low as 0.2 nM. The shorter (25-100 um) CF electrodes are suitable for in vivo amperometric and voltammetric measurements. When used with the Micro-C Potentiostat, these CF electrodes can be activated and renewed in sensitivity for multiple use. The selective detection of catecholamines can be achieved with our Nafion-coated CF electrodes. For selective detection of 5-HT, please contact WPI for more information.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cimg style=\"margin: 5px; width: 412px; height: 267px;\" title=\"microcfig2.jpg\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/microcfig2_a6b6f373-ebd0-4c58-ac83-2e305bd7285b.jpg?v=1765945859\" alt=\"microcfig2.jpg\" width=\"412\" height=\"267\"\u003e\u003cbr\u003eFig. 2-Extracellular recording using a carbon electrode in CA1 region of the hippocampus in an anesthetized rat shows ultra-low noise ( ≤5μV). Courtesy: Dr. Carolyn Harley of Memorial University, Newfoundland, Canada.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/CF10CF30_IMs.pdf\"\u003eCF10\/CF30 Carbon Fiber Microelectrodes Instruction Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:references --\u003e\n\u003cp\u003e\u003cstrong\u003eL. Yavich, P. Jkl, H.Tanila\u003c\/strong\u003e \"Noradrenaline overflow in mouse dentate gyrus following locus coeruleus and natural stimulation: real-time monitoring by in vivo voltammetry\" \u003cspan style=\"font-style: italic;\"\u003eJ of Neurochemistry\u003c\/span\u003e 95. 2005: 641-650\u003c\/p\u003e\n\u003c!-- \/section:references --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266106265690,"sku":"CFN30-50","price":617.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/cf10-500_8_0864a9ce-c4c4-491d-aed3-24568507c0b4.jpg?v=1766397080"}],"url":"https:\/\/wpiinc.com\/collections\/neurotransmitter-detection.oembed","provider":"World Precision Instruments","version":"1.0","type":"link"}