{"title":"Mono Platinum Iridium","description":"\u003cdiv id=\"headerarea\"\u003e\n\u003cp\u003eOur extra-fine tip profile features a significantly sharper taper as well as a thinner insulation layer.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.wpi-europe.com\/images\/content\/extra-fine-tip.png\" alt=\"\" width=\"243\" height=\"161\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"content\"\u003e\n\u003cdiv id=\"productcategories\"\u003e\n\u003cdiv class=\"su-tabs  su-tabs-align-center su-tabs-style-2\" data-active=\"1\"\u003e\n\u003cdiv class=\"su-tabs-panes\"\u003e\n\u003ch3 class=\"su-tabs-pane su-clearfix\"\u003eTungsten - Extra Fine Tip - (75 µm X 3\")\u003cbr\u003e \u003c\/h3\u003e\n\u003cdiv class=\"su-tabs-pane su-clearfix\"\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable class=\"table table-striped table-hover csstable\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"sub-title-table\"\u003e\n\u003ctd\u003e\u003cstrong\u003eITEM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eShaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTip Diameter (µm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTip Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance (mOhms)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9315\"\u003eWE30010.01F3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.081 mm\u003c\/td\u003e\n\u003ctd\u003e1-2 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e0.01 meg\u003c\/td\u003e\n\u003ctd\u003eMultiUnit \u0026amp; ERP recording \u0026amp; Stim\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9411\"\u003eWE30010.05F3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.081 mm\u003c\/td\u003e\n\u003ctd\u003e1-2 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e0.05 meg\u003c\/td\u003e\n\u003ctd\u003eMultiUnit \u0026amp; ERP recording \u0026amp; Stim\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9412\"\u003eWE30010.1F3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.081 mm\u003c\/td\u003e\n\u003ctd\u003e1-2 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e0.1 meg\u003c\/td\u003e\n\u003ctd\u003eMultiUnit \u0026amp; ERP recording \u0026amp; Stim\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9413\"\u003eWE30010.5F3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.081 mm\u003c\/td\u003e\n\u003ctd\u003e1-2 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e0.5 meg\u003c\/td\u003e\n\u003ctd\u003eSingle \u0026amp; multiunit rec. \u0026amp; stim.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9414\"\u003eWE30011.0F3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.081 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e1.0 meg\u003c\/td\u003e\n\u003ctd\u003eSingle \u0026amp; multiunit rec. \u0026amp; stim.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9415\"\u003eWE30011.5F3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.081 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e1.5 meg\u003c\/td\u003e\n\u003ctd\u003eSingle \u0026amp; multiunit rec. \u0026amp; stim.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9416\"\u003eWE30012.0F3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.081 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e2.0 meg\u003c\/td\u003e\n\u003ctd\u003eGreater Selectivity \u0026amp; Micro. Stim.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9417\"\u003eWE30012.5F3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.081 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e2.5 meg\u003c\/td\u003e\n\u003ctd\u003eGreater Selectivity - Small Cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9418\"\u003eWE30013.0F3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.081 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e3.0 meg\u003c\/td\u003e\n\u003ctd\u003eGreater Selectivity - Small Cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9419\"\u003eWE30015.0F3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.081 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e5.0 meg\u003c\/td\u003e\n\u003ctd\u003eGreater Selectivity - Small Cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e \u003c\/h3\u003e\n\u003ch3\u003eTungsten - Extra Fine Tip - with Polyimide Tubing - (75 µm X 3\")\u003c\/h3\u003e\n\u003ctable class=\"table table-striped table-hover csstable\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"sub-title-table\"\u003e\n\u003ctd\u003e\u003cstrong\u003eITEM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eShaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTip Diameter (µm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTip Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance (mOhms)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9420\"\u003eWE3PT10.01F3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.145 mm\u003c\/td\u003e\n\u003ctd\u003e1-2 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e0.01 meg\u003c\/td\u003e\n\u003ctd\u003eMultiUnit \u0026amp; ERP recording \u0026amp; Stim\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9421\"\u003eWE3PT10.05F3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.145 mm\u003c\/td\u003e\n\u003ctd\u003e1-2 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e0.05 meg\u003c\/td\u003e\n\u003ctd\u003eMultiUnit \u0026amp; ERP recording \u0026amp; Stim\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9422\"\u003eWE3PT10.1F3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.145 mm\u003c\/td\u003e\n\u003ctd\u003e1-2 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e0.1 meg\u003c\/td\u003e\n\u003ctd\u003eMultiUnit \u0026amp; ERP recording \u0026amp; Stim\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9423\"\u003eWE3PT10.5F3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.145 mm\u003c\/td\u003e\n\u003ctd\u003e1-2 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e0.5 meg\u003c\/td\u003e\n\u003ctd\u003eSingle \u0026amp; multiunit rec. \u0026amp; stim.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9424\"\u003eWE3PT11.0F3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.145 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e1.0 meg\u003c\/td\u003e\n\u003ctd\u003eSingle \u0026amp; multiunit rec. \u0026amp; stim.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9425\"\u003eWE3PT11.5F3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.145 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e1.5 meg\u003c\/td\u003e\n\u003ctd\u003eSingle \u0026amp; multiunit rec. \u0026amp; stim.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9426\"\u003eWE3PT12.0F3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.145 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e2.0 meg\u003c\/td\u003e\n\u003ctd\u003eGreater Selectivity \u0026amp; Micro. Stim.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9427\"\u003eWE3PT12.5F3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.145 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e2.5 meg\u003c\/td\u003e\n\u003ctd\u003eGreater Selectivity - Small Cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9428\"\u003eWE3PT13.0F3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.145 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e3.0 meg\u003c\/td\u003e\n\u003ctd\u003eGreater Selectivity - Small Cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9429\"\u003eWE3PT15.0F3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.145 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e5.0 meg\u003c\/td\u003e\n\u003ctd\u003eGreater Selectivity - Small Cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e \u003c\/h3\u003e\n\u003ch3\u003eTungsten - Extra Fine Tip - (125 µm X 3\")\u003c\/h3\u003e\n\u003ctable class=\"table table-striped table-hover csstable\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"sub-title-table\"\u003e\n\u003ctd\u003e\u003cstrong\u003eITEM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eShaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTip Diameter (µm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTip Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance (mOhms)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9431\"\u003eWE30010.01F5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.127 mm\u003c\/td\u003e\n\u003ctd\u003e1-2 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e0.01 meg\u003c\/td\u003e\n\u003ctd\u003eMultiUnit \u0026amp; ERP recording \u0026amp; Stim\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9432\"\u003eWE30010.05F5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.127 mm\u003c\/td\u003e\n\u003ctd\u003e1-2 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e0.05 meg\u003c\/td\u003e\n\u003ctd\u003eMultiUnit \u0026amp; ERP recording \u0026amp; Stim\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9444\"\u003eWE30010.1F5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.127 mm\u003c\/td\u003e\n\u003ctd\u003e1-2 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e0.1 meg\u003c\/td\u003e\n\u003ctd\u003eMultiUnit \u0026amp; ERP recording \u0026amp; Stim\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9445\"\u003eWE30010.5F5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.127 mm\u003c\/td\u003e\n\u003ctd\u003e1-2 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e0.5 meg\u003c\/td\u003e\n\u003ctd\u003eSingle \u0026amp; multiunit rec. \u0026amp; stim.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9434\"\u003eWE30011.0F5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.127 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e1.0 meg\u003c\/td\u003e\n\u003ctd\u003eSingle \u0026amp; multiunit rec. \u0026amp; stim.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9435\"\u003eWE30011.5F5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.127 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e1.5 meg\u003c\/td\u003e\n\u003ctd\u003eSingle \u0026amp; multiunit rec. \u0026amp; stim.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9436\"\u003eWE30012.0F5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.127 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e2.0 meg\u003c\/td\u003e\n\u003ctd\u003eGreater Selectivity \u0026amp; Micro. Stim.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9437\"\u003eWE30012.5F5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.127 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e2.5 meg\u003c\/td\u003e\n\u003ctd\u003eGreater Selectivity - Small Cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9438\"\u003eWE30013.0F5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.127 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e3.0 meg\u003c\/td\u003e\n\u003ctd\u003eGreater Selectivity - Small Cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9451\"\u003eWE30014.0F5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.127 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e4.0 meg\u003c\/td\u003e\n\u003ctd\u003eGreater Selectivity - Small Cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9452\"\u003eWE30015.0F5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.127 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e5.0 meg\u003c\/td\u003e\n\u003ctd\u003eGreater Selectivity - Small Cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9453\"\u003eWE30016.0F5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.127 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e6.0 meg\u003c\/td\u003e\n\u003ctd\u003eGreater Selectivity - Small Cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e \u003c\/h3\u003e\n\u003ch3\u003eTungsten - Extra Fine Tip - with Polyimide Tubing - (125 µm X 3\")\u003c\/h3\u003e\n\u003ctable class=\"table table-striped table-hover csstable\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"sub-title-table\"\u003e\n\u003ctd\u003e\u003cstrong\u003eITEM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eShaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTip Diameter (µm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTip Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance (mOhms)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9442\"\u003eWE3PT10.01F5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.216 mm\u003c\/td\u003e\n\u003ctd\u003e1-2 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e0.01 meg\u003c\/td\u003e\n\u003ctd\u003eMultiUnit \u0026amp; ERP recording \u0026amp; Stim\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9443\"\u003eWE3PT10.05F5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.216 mm\u003c\/td\u003e\n\u003ctd\u003e1-2 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e0.05 meg\u003c\/td\u003e\n\u003ctd\u003eMultiUnit \u0026amp; ERP recording \u0026amp; Stim\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9433\"\u003eWE3PT10.1F5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.216 mm\u003c\/td\u003e\n\u003ctd\u003e1-2 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e0.1 meg\u003c\/td\u003e\n\u003ctd\u003eMultiUnit \u0026amp; ERP recording \u0026amp; Stim\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9430\"\u003eWE3PT10.5F5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.216 mm\u003c\/td\u003e\n\u003ctd\u003e1-2 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e0.5 meg\u003c\/td\u003e\n\u003ctd\u003eSingle \u0026amp; multiunit rec. \u0026amp; stim.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9446\"\u003eWE3PT11.0F5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.216 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e1.0 meg\u003c\/td\u003e\n\u003ctd\u003eSingle \u0026amp; multiunit rec. \u0026amp; stim.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9447\"\u003eWE3PT11.5F5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.216 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e1.5 meg\u003c\/td\u003e\n\u003ctd\u003eSingle \u0026amp; multiunit rec. \u0026amp; stim.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9448\"\u003eWE3PT12.0F5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.216 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e2.0 meg\u003c\/td\u003e\n\u003ctd\u003eGreater Selectivity \u0026amp; Micro. Stim.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9449\"\u003eWE3PT12.5F5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.216 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e2.5 meg\u003c\/td\u003e\n\u003ctd\u003eGreater Selectivity - Small Cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9450\"\u003eWE3PT13.0F5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.216 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e3.0 meg\u003c\/td\u003e\n\u003ctd\u003eGreater Selectivity - Small Cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9439\"\u003eWE3PT14.0F5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.216 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e4.0 meg\u003c\/td\u003e\n\u003ctd\u003eGreater Selectivity - Small Cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9440\"\u003eWE3PT15.0F5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.216 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e5.0 meg\u003c\/td\u003e\n\u003ctd\u003eGreater Selectivity - Small Cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/amplifiers\/accessories\/metal-microelectrodes\/monopolar-electrodes\/tungsten-microelectrodes\/extra-fine-tip-profile.aspx#productlistitem9441\"\u003eWE3PT16.0F5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e0.216 mm\u003c\/td\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003ctd\u003eExtra Fine\u003c\/td\u003e\n\u003ctd\u003e6.0 meg\u003c\/td\u003e\n\u003ctd\u003eGreater Selectivity - Small Cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003cdiv id=\"productcategories\"\u003e\u003c\/div\u003e","products":[{"product_id":"var-8089-pure-iridium-metal-electrodes-profile-c","title":"Pure Iridium Metal Electrodes Profile C","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMulti unit and single unit recording\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePure Iridium Metal Electrodes Profile C Comparison Chart\u003c\/strong\u003e \u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" class=\"sortable\" id=\"c1\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003cth style=\"background-color: #0081c2;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003eOrder code\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"background-color: #0081c2;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"background-color: #0081c2;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eInsulation\u003cbr\u003eThickness\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"background-color: #0081c2;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eShaft\u003cbr\u003eDiameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"background-color: #0081c2;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eNominal\u003cbr\u003eImpedance\u003cbr\u003e±20%\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"background-color: #0081c2;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eTip\u003cbr\u003eDiameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"background-color: #0081c2;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eTypical Use\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eIRM23E05KT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50mm\u003c\/td\u003e\n\u003ctd\u003e3µ\u003c\/td\u003e\n\u003ctd\u003e0.180 mm\u003c\/td\u003e\n\u003ctd\u003e0.5 MΩ\u003c\/td\u003e\n\u003ctd\u003e2-3µ\u003c\/td\u003e\n\u003ctd\u003eMultiunit \u0026amp; ERP recording \u0026amp; stimulation \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eIRM23E15KT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50mm\u003c\/td\u003e\n\u003ctd\u003e3µ\u003c\/td\u003e\n\u003ctd\u003e0.180 mm\u003c\/td\u003e\n\u003ctd\u003e1.5 MΩ\u003c\/td\u003e\n\u003ctd\u003e1-2µ\u003c\/td\u003e\n\u003ctd\u003eSingle and multiunit recording and stimulation \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eIRM23E20KT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50mm\u003c\/td\u003e\n\u003ctd\u003e3µ\u003c\/td\u003e\n\u003ctd\u003e0.180 mm\u003c\/td\u003e\n\u003ctd\u003e2.0 MΩ\u003c\/td\u003e\n\u003ctd\u003e1-2µ\u003c\/td\u003e\n\u003ctd\u003eGreater selectivity \u0026amp; microstimulation \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eIRM23E30KT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50mm\u003c\/td\u003e\n\u003ctd\u003e3µ\u003c\/td\u003e\n\u003ctd\u003e0.180 mm\u003c\/td\u003e\n\u003ctd\u003e3.0 MΩ\u003c\/td\u003e\n\u003ctd\u003e1-2µ\u003c\/td\u003e\n\u003ctd\u003eGreater selectivity - small cells \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTypical Use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMulti unit and single unit recording and stimulation\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKapton tubing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eKapton tubing, indicated by “KT” in the part number, extends from the connector to within 5 mm of the tip, providing stiffness and additional insulation to the electrode shaft. Kapton-clad electrodes are recommended when the electrode is to be inserted through a cannula for extra deep penetration.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/MetalMicroelectrodes_IS.pdf\" target=\"_self\"\u003eUsing Parylene Coated Metal Microelectrodes\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat length do I need?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe overall length of any electrode system is determined primarily on the depth of the tissue one wishes to record or stimulate and the micro-drive system being employed. Tungsten microprobes come in 76 mm or 125 mm (don’t see 125 um on WPI website) lengths or can be custom ordered in any length less than 5 inches. Platinum\/Iridium typically comes in two inch lengths and stainless steel in 51 mm lengths but either can also be specified in shorter lengths or in longer lengths using stainless steel and polyimide tubing. Because of the high expense of pure iridium it is always mounted in stainless steel and polyimide tubing and is typically 50 mm long.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat is the insulation thickness?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAll electrodes except the 3 inch Extra Fine-F profile tungsten microprobe, that have a 1 micron coat of Parylene-C insulation, have 3 microns of Parylene-C. It has been proven that this thickness works best for most all electrode tip profiles we offer. We selected 3 microns to provide a sufficiently small tip profile for getting close to neural elements, ease of electrode insertion and to minimize attenuation for higher impedance electrodes. Attenuation of the signal can occur as a result of capacitive shunting when recording with higher impedance microprobes in deep structures, so additional insulation maybe required in the form of WPI’s KT, polyimide microprobes. The Extra Fine profile (ex. TM31C10) for the 3 inch tungsten electrodes provides an extremely fine microprobe tip which is excellent when recording from small densely packed cell structures.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat tip impedance or exposure do I need?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBecause of our unique fabrication process and the special properties of Parylene-C we are able to expose any microprobe with microscopic precision and reproducibility. Each microprobe is individually exposed under a high power microscope, inspected and electrically characterized. Our microprobes have a lower impedance value for the same tip exposure as other commercially available electrodes. It is therefore recommended that those who have not used our electrodes before specify a range of impedance in order to select the best impedance value for their application. Also since we have been providing microprobes to researchers for over 30 years, we can provide expert advice in selecting the best electrode design for your experimental paradigm. Please contact us and provide information regarding your researcher’s requirements. There is no additional charge for specifying a range of impedance values for any box of microprobes.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat tip profile is best for my application?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe offer a variety of different tip alternatives for those that prefer a specialized electrode profile for their research. The tip selection can provide subtle yet important changes to the performance of the electrode, as described below. It is recommended that first time users consider experimenting with different tip profiles to determine which works best for their recording or stimulation protocols. A-Standard Our standard tip profile features a sharp yet robust point that offers versatile performance and an effective balance between penetration and durability. The most widely used tip profile, we recommend our standard tip for most neural recording applications, though it is also effective for most stimulation protocols. We employ an arc exposure method that provides precise and consistent performance as well as a very wide range of available impedances. While this method results in a small variability in impedance from electrode to electrode, most researchers find it very acceptable for their application. For those that need a more exact tip exposure, we offer a laser exposure service for a small premium. Please contact us if you feel this service is right for you. B-Blunted Our blunted electrodes are engineered to have a more rounded, bullet-shaped tip. For many applications the blunted tip can offer superior stimulation performance, as its shorter profile can lead to the electrode acting more as a point source and providing improved isolation. Many investigators feel that this profile both provides greater selectivity than the conventional sharper tip profiles and is more appropriate for higher-intensity stimulation protocols. Some investigators have also reported observations that the use of blunted tips leads to fewer occurrences of punctured cells. F-Extra fine Our extra-fine tip profile features a significantly sharper taper as well as a thinner insulation layer. This type of electrode is commonly used for shallow preparations where it is necessary to record from small tightly-packed cell populations, such as the striate layers of the visual and auditory cortices. Due to the very delicate nature of these tips, they are only available in tungsten electrodes, in 3-inch (76mm) length and both 0.003\" and 0.005\" (75 and 125 micron) shaft diameter. For penetrations greater than 4 mm in which the tip impedance is greater than 1.5 MΩ, we recommend that an additional layer of polyimide tubing be specified to reduce capacitive shunting and to increase the stiffness of the electrode. H-Heat Treated Our heat-treated electrodes are intended for those investigators who must penetrate their probes through tough membranes, such as the dura mater of larger mammals. By applying a heat source near the electrode tip under a microscope, we have the ability to provide an electrode with a more gradual tapering tip than our standard profile, while also toughening the polymer insulation near the tip. These modifications allow the electrode to be pushed through tough membranes easier and with less risk of tip and insulation damage.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eProblems reading the impedance of your metal microelectrodes?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003col\u003e\n\u003cli\u003eCheck your impedance tester, maybe you are testing the impedance values at a different frequency than the 1 Kilohertz.\u003c\/li\u003e\n\u003cli\u003eCheck if your impedance tester doesn’t have a sample and hold circuit in which case the impedance is measured immediately upon pressing the test button and the impedance does not have a chance to stabilize.\u003c\/li\u003e\n\u003cli\u003eUsually the impedance will drop after a few minutes of the electrode being in the saline solution.\u003c\/li\u003e\n\u003cli\u003eSometimes the electrodes can oxidize increasing the impedance in which case we recommend passing about negative 3 to 4.5 volts across the electrode in saline to clean and de-oxidize the electrode.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat electrode configuration do I need?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe presently offer three different electrode configurations at this time, although we have fabricated many custom designs for customers in the past. As you observe what our part numbers look like for our probes, as seen under our Product section, you will notice they have a part number like WE30031.0A5. The 00 portion of the part number specifies the microprobe configuration. Monopolar Electrodes - 00 Implies no special mounting with the sharpened probe being insulated with Parylene-C, having the length, width, tip profile and impedance as specified in the tables for ordering your electrodes. Polyimide Tubing - PT Electrodes which have been mounted into polyimide tubing in order to increase the stiffness and provide additional insulation thickness. This mounting is typically recommended when fairly high impedance electrodes must penetrate deeper layers of the brain or spinal cord. ST Specifies our bipolar or stereotrodes. These electrodes when ordered with impedances less than 0.5 meohms are excellent for localizing stimulation current fields. Higher impedance stereotrodes are excellent for enhancing the isolation of single neural elements by simultaneous recording of multiple units on two closely spaced microelectrodes. The tip spacing is typically equal to the shaft diameter of one of the electrodes used in making the stereotrode. Different tip spacing is available upon request.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat type of connectors are used with our electrodes?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 5482, 5483 pin connectors are attached to the distal end of our electrodes. You can purchase these connectors as well as the mating connector, M202, by clicking here and going to our Accessory Page. Many users prefer to use our electrodes without any connector, which is fine. We will simply remove the connectors for you if requested. There is no discount for this since the connectors are attached at the beginning our fabrication process.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat are the tip exposures for different electrode impedance values?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTip exposures for Heat Tapered \"H\" tip profiles have approximately 15 to 20 percent MORE exposure. Tip exposures for Blunted \"B\" tip profiles have approximately 15 to 20 percent LESS exposure. Tip exposures for Extra Fine \"F\" tip profiles have approximately 10 to 15 percent MORE exposure.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eProblems reading the impedance of your metal microelectrodes?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003col\u003e\n\u003cli\u003eCheck your impedance tester, maybe you are testing the impedance values at a different frequency than the 1 Kilohertz.\u003c\/li\u003e\n\u003cli\u003eCheck if your impedance tester doesn’t have a sample and hold circuit in which case the impedance is measured immediately upon pressing the test button and the impedance does not have a chance to stabilize.\u003c\/li\u003e\n\u003cli\u003eUsually the impedance will drop after a few minutes of the electrode being in the saline solution.\u003c\/li\u003e\n\u003cli\u003eSometimes the electrodes can oxidize increasing the impedance in which case we recommend passing about negative 3 to 4.5 volts across the electrode in saline to clean and de-oxidize the electrode.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"0.180 mm|0.5 Mohm","offer_id":42265682935898,"sku":"IRM23E05KT","price":672.0,"currency_code":"USD","in_stock":true},{"title":"0.180 mm|1.5 Mohm","offer_id":42265682968666,"sku":"IRM23E15KT","price":672.0,"currency_code":"USD","in_stock":true},{"title":"0.180 mm|2.0 Mohm","offer_id":42265683001434,"sku":"IRM23E20KT","price":672.0,"currency_code":"USD","in_stock":true},{"title":"0.180 mm|3.0 Mohm","offer_id":42265682903130,"sku":"IRM23E30KT","price":672.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/monopolar-wpolyimide-tubing_3_77084ad7-6d43-48f7-8584-9dad2b1ae51a.png?v=1766393478"},{"product_id":"ptm23b05-platinum-iridium-metal-electrodes-profile-a","title":"Platinum Iridium Metal Electrodes Profile A","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePlatinum-iridium electrodes\u003c\/li\u003e\n\u003cli\u003eFor Chronic recording and microstimulation\u003c\/li\u003e\n\u003cli\u003ePackage of 5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%;\" colspan=\"2\"\u003e\n\u003ch2\u003ePROS\u003c\/h2\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 11%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/lower-concomitant-impedance_b4808d9a-8e8c-42b3-8150-12b15d4feb45.jpg?v=1765947447\" alt=\"lower concomitant impedance\" width=\"100\" height=\"100\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: #0081c2;\"\u003eLower Concomitant Impedance\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThis probe has lower concomitant impedance compared with tungsten and stainless steel.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 11%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/higher-charge-_transfer-capacity_4aad9dab-deee-4a86-82ad-23e604d434fa.jpg?v=1765947453\" alt=\"higher charge transfer capacity\" width=\"100\" height=\"100\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: #0081c2;\"\u003eHigher Charge Transfer Capacity\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eMaking it perfect for microstimulation, Pt-Ir electrodes have a higher charge transfer capacity compared with tungsten and stainless steel.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 11%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/improved-electrochemical-stability_e0123693-cef1-4070-9740-7dc75ae209bf.jpg?v=1765947459\" alt=\"improved electrochemical stability\" width=\"100\" height=\"100\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: #0081c2;\"\u003eImproved Electrochemical Stability\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003ePt-Ir offers improved electrochemical stability compared with tungsten and stainless steel.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 11%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/Perfect-microstimulation_73dfb894-1227-40fc-b55c-4c2715c670df.jpg?v=1765947465\" alt=\"Perfect for microstimulation\" width=\"100\" height=\"100\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: #0081c2;\"\u003ePerfect for Microstimulation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003ePerfect for microstimulation, with excellent performance that ensures safe stimulation even with small probes.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 11%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/bend-_resistance_e9cce1e3-25b7-4948-8088-d1927ea0b2c6.jpg?v=1765947472\" alt=\"Iridium content improves bendresistance\" width=\"100\" height=\"100\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: #0081c2;\"\u003eIridium Content Improves Bend Resistance\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eIridium content in the alloy increases the mechanical hardness, which stiffens the electrode to the point that the bend resistance comes close to that of tungsten.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 11%;\" colspan=\"2\"\u003e\n\u003ch2\u003eCONSIDERATIONS\u003c\/h2\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 11%;\" colspan=\"2\"\u003e\n\u003ch3\u003eAre you performing acute recordings or non-intensive chronic recordings?\u003c\/h3\u003e\n\u003cp\u003eYou may be able to use a tungsten probe instead. Platinum-iridium costs more than tungsten and stainless steel, which makes it less desirable for acute recording and non-intensive chronic recording.\u003c\/p\u003e\n\u003ch3\u003eWill you perform intensive stimulation protocols?\u003c\/h3\u003e\n\u003cp\u003eIntensive stimulation protocols could make platinum-iridium probes succeptible to corrosion and dissolution.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cstrong style=\"font-size: 12px;\"\u003ePlatinum Iridium Profile A Comparison Chart\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable id=\"a1\" class=\"sortable\" border=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr bgcolor=\"#e4e4e4\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003cth\u003eInsulation\u003cbr\u003eThickness\u003c\/th\u003e\n\u003cth\u003eShaft\u003cbr\u003eDiameter\u003c\/th\u003e\n\u003cth\u003eNominal\u003cbr\u003eImpedance\u003cbr\u003e±20%\u003c\/th\u003e\n\u003cth\u003eTip\u003cbr\u003eDiameter\u003c\/th\u003e\n\u003cth\u003eTypical Use\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePTM23B05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51mm\u003c\/td\u003e\n\u003ctd\u003e 3µ\u003c\/td\u003e\n\u003ctd\u003e0.231mm\u003c\/td\u003e\n\u003ctd\u003e0.5MΩ\u003c\/td\u003e\n\u003ctd\u003e2-3µ\u003c\/td\u003e\n\u003ctd\u003eSingle and multi unit recording, stimulation, chronic implant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTypical Use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSingle and multi unit recording, stimulation, chronic implants\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/index.php?src=blog\u0026amp;srctype=detail\u0026amp;refno=19\u0026amp;category=Product%20Information\"\u003e\u003cstrong\u003eSee Metal Microelectrode Selection Guide\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/MetalMicroelectrodes_IS.pdf\" target=\"_self\"\u003eUsing Parylene Coated Metal Microelectrodes\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003ch2\u003eFAQ\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003eWhat length do I need?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eThe overall length of any electrode system is determined primarily on the depth of the tissue one wishes to record or stimulate and the micro-drive system being employed. Tungsten microprobes come in 76 mm or 125 mm (don’t see 125 um on WPI website) lengths or can be custom ordered in any length less than 5 inches. Platinum\/Iridium typically comes in two inch lengths and stainless steel in 51 mm lengths but either can also be specified in shorter lengths or in longer lengths using stainless steel and polyimide tubing. Because of the high expense of pure iridium it is always mounted in stainless steel and polyimide tubing and is typically 50 mm long.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003eWhat is the insulation thickness?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eAll electrodes except the 3 inch Extra Fine-F profile tungsten microprobe, that have a 1 micron coat of Parylene-C insulation, have 3 microns of Parylene-C. It has been proven that this thickness works best for most all electrode tip profiles we offer. We selected 3 microns to provide a sufficiently small tip profile for getting close to neural elements, ease of electrode insertion and to minimize attenuation for higher impedance electrodes. Attenuation of the signal can occur as a result of capacitive shunting when recording with higher impedance microprobes in deep structures, so additional insulation maybe required in the form of WPI’s KT, polyimide microprobes. The Extra Fine profile (ex. TM31C10) for the 3 inch tungsten electrodes provides an extremely fine microprobe tip which is excellent when recording from small densely packed cell structures.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003eWhat tip impedance or exposure do I need?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eBecause of our unique fabrication process and the special properties of Parylene-C we are able to expose any microprobe with microscopic precision and reproducibility. Each microprobe is individually exposed under a high power microscope, inspected and electrically characterized. Our microprobes have a lower impedance value for the same tip exposure as other commercially available electrodes. It is therefore recommended that those who have not used our electrodes before specify a range of impedance in order to select the best impedance value for their application. Also since we have been providing microprobes to researchers for over 30 years, we can provide expert advice in selecting the best electrode design for your experimental paradigm. Please contact us and provide information regarding your researcher’s requirements. There is no additional charge for specifying a range of impedance values for any box of microprobes.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003eWhat tip profile is best for my application?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eWe offer a variety of different tip alternatives for those that prefer a specialized electrode profile for their research. The tip selection can provide subtle yet important changes to the performance of the electrode, as described below. It is recommended that first time users consider experimenting with different tip profiles to determine which works best for their recording or stimulation protocols. A-Standard Our standard tip profile features a sharp yet robust point that offers versatile performance and an effective balance between penetration and durability. The most widely used tip profile, we recommend our standard tip for most neural recording applications, though it is also effective for most stimulation protocols. We employ an arc exposure method that provides precise and consistent performance as well as a very wide range of available impedances. While this method results in a small variability in impedance from electrode to electrode, most researchers find it very acceptable for their application. For those that need a more exact tip exposure, we offer a laser exposure service for a small premium. Please contact us if you feel this service is right for you. B-Blunted Our blunted electrodes are engineered to have a more rounded, bullet-shaped tip. For many applications the blunted tip can offer superior stimulation performance, as its shorter profile can lead to the electrode acting more as a point source and providing improved isolation. Many investigators feel that this profile both provides greater selectivity than the conventional sharper tip profiles and is more appropriate for higher-intensity stimulation protocols. Some investigators have also reported observations that the use of blunted tips leads to fewer occurrences of punctured cells. F-Extra fine Our extra-fine tip profile features a significantly sharper taper as well as a thinner insulation layer. This type of electrode is commonly used for shallow preparations where it is necessary to record from small tightly-packed cell populations, such as the striate layers of the visual and auditory cortices. Due to the very delicate nature of these tips, they are only available in tungsten electrodes, in 3-inch (76mm) length and both 0.003\" and 0.005\" (75 and 125 micron) shaft diameter. For penetrations greater than 4 mm in which the tip impedance is greater than 1.5 MΩ, we recommend that an additional layer of polyimide tubing be specified to reduce capacitive shunting and to increase the stiffness of the electrode. H-Heat Treated Our heat-treated electrodes are intended for those investigators who must penetrate their probes through tough membranes, such as the dura mater of larger mammals. By applying a heat source near the electrode tip under a microscope, we have the ability to provide an electrode with a more gradual tapering tip than our standard profile, while also toughening the polymer insulation near the tip. These modifications allow the electrode to be pushed through tough membranes easier and with less risk of tip and insulation damage.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003eProblems reading the impedance of your metal microelectrodes?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003col\u003e\r\n\u003cli\u003eCheck your impedance tester, maybe you are testing the impedance values at a different frequency than the 1 Kilohertz.\u003c\/li\u003e\r\n\u003cli\u003eCheck if your impedance tester doesn’t have a sample and hold circuit in which case the impedance is measured immediately upon pressing the test button and the impedance does not have a chance to stabilize.\u003c\/li\u003e\r\n\u003cli\u003eUsually the impedance will drop after a few minutes of the electrode being in the saline solution.\u003c\/li\u003e\r\n\u003cli\u003eSometimes the electrodes can oxidize increasing the impedance in which case we recommend passing about negative 3 to 4.5 volts across the electrode in saline to clean and de-oxidize the electrode.\u003c\/li\u003e\r\n\u003c\/ol\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003eWhat electrode configuration do I need?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eWe presently offer three different electrode configurations at this time, although we have fabricated many custom designs for customers in the past. As you observe what our part numbers look like for our probes, as seen under our Product section, you will notice they have a part number like WE30031.0A5. The 00 portion of the part number specifies the microprobe configuration. Monopolar Electrodes - 00 Implies no special mounting with the sharpened probe being insulated with Parylene-C, having the length, width, tip profile and impedance as specified in the tables for ordering your electrodes. Polyimide Tubing - PT Electrodes which have been mounted into polyimide tubing in order to increase the stiffness and provide additional insulation thickness. This mounting is typically recommended when fairly high impedance electrodes must penetrate deeper layers of the brain or spinal cord. ST Specifies our bipolar or stereotrodes. These electrodes when ordered with impedances less than 0.5 meohms are excellent for localizing stimulation current fields. Higher impedance stereotrodes are excellent for enhancing the isolation of single neural elements by simultaneous recording of multiple units on two closely spaced microelectrodes. The tip spacing is typically equal to the shaft diameter of one of the electrodes used in making the stereotrode. Different tip spacing is available upon request.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003eWhat type of connectors are used with our electrodes?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eThe 5482, 5483 pin connectors are attached to the distal end of our electrodes. You can purchase these connectors as well as the mating connector, M202, by clicking here and going to our Accessory Page. Many users prefer to use our electrodes without any connector, which is fine. We will simply remove the connectors for you if requested. There is no discount for this since the connectors are attached at the beginning our fabrication process.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003eWhat are the tip exposures for different electrode impedance values?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eTip exposures for Heat Tapered \"H\" tip profiles have approximately 15 to 20 percent MORE exposure. Tip exposures for Blunted \"B\" tip profiles have approximately 15 to 20 percent LESS exposure. Tip exposures for Extra Fine \"F\" tip profiles have approximately 10 to 15 percent MORE exposure.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003eProblems reading the impedance of your metal microelectrodes?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003col\u003e\r\n\u003cli\u003eCheck your impedance tester, maybe you are testing the impedance values at a different frequency than the 1 Kilohertz.\u003c\/li\u003e\r\n\u003cli\u003eCheck if your impedance tester doesn’t have a sample and hold circuit in which case the impedance is measured immediately upon pressing the test button and the impedance does not have a chance to stabilize.\u003c\/li\u003e\r\n\u003cli\u003eUsually the impedance will drop after a few minutes of the electrode being in the saline solution.\u003c\/li\u003e\r\n\u003cli\u003eSometimes the electrodes can oxidize increasing the impedance in which case we recommend passing about negative 3 to 4.5 volts across the electrode in saline to clean and de-oxidize the electrode.\u003c\/li\u003e\r\n\u003c\/ol\u003e\r\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266221019226,"sku":"PTM23B05","price":420.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/monopolar-electrodes-wpi_3_1_1_6_48cf5b8d-6901-4602-8edc-f50017cfc7d2.jpg?v=1766399163"},{"product_id":"ptm23b10kt-platinum-iridium-metal-electrodes-profile-c-51-mm-long","title":"Platinum Iridium Metal Electrodes Profile C , 51 mm long-PTM23B10KT","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePlatinum Iridium Profile C, 51 mm \u003c\/li\u003e\n\u003cli\u003eLength : 51 mm\u003c\/li\u003e\n\u003cli\u003eInsulation Thickness : 3µ\u003c\/li\u003e\n\u003cli\u003eShaft Diameter : 0.356mm\u003c\/li\u003e\n\u003cli\u003eNominal Impedance\u003cspan style=\"color: #000000;\"\u003e ±20%\u003c\/span\u003e: 1.0MΩ\u003c\/li\u003e\n\u003cli\u003eTip Diameter : 1-2µ\u003c\/li\u003e\n\u003cli\u003eTypical Use : Single and multi unit recording, stimulation, chronic implants.\u003c\/li\u003e\n\u003cli\u003eQuantity : Package of 5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKapton tubing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eKapton tubing, indicated by “KT” in the part number, extends from the connector to within 5 mm of the tip, providing stiffness and additional insulation to the electrode shaft. Kapton-clad electrodes are recommended when the electrode is to be inserted through a cannula for extra deep penetration.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/index.php?src=blog\u0026amp;srctype=detail\u0026amp;refno=19\u0026amp;category=Product%20Information\"\u003eSee Metal Microelectrode Selection Guide\u003c\/a\u003e\u003ca href=\"\/index.php?src=blog\u0026amp;srctype=detail\u0026amp;refno=19\u0026amp;category=Product%20Information\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/MetalMicroelectrodes_IS.pdf\" target=\"_self\"\u003eUsing Parylene Coated Metal Microelectrodes\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266350288986,"sku":"PTM23B10KT","price":645.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/profilecsingleelectrodewpolymidetubing_68b4fcd6-4166-4287-8b67-179efd4c2406.jpg?v=1766402736"},{"product_id":"ptm123b05kt-platinum-iridium-metal-electrodes-profile-c-305-mm-long","title":"Platinum Iridium Metal Electrodes Profile C , 305 mm long","description":"\u003c!-- section:details --\u003e\n\u003ctable id=\"a1\" class=\"sortable\" style=\"width: 924px;\" border=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr bgcolor=\"#e4e4e4\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003cth\u003eInsulation\u003cbr\u003eThickness\u003c\/th\u003e\n\u003cth\u003eShaft\u003cbr\u003eDiameter\u003c\/th\u003e\n\u003cth\u003eNominal\u003cbr\u003eImpedance\u003cbr\u003e±20%\u003c\/th\u003e\n\u003cth\u003eTip\u003cbr\u003eDiameter\u003c\/th\u003e\n\u003cth\u003eTypical Use\u003c\/th\u003e\n\u003cth\u003eQuantity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePTM123B05KT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305mm\u003c\/td\u003e\n\u003ctd\u003e3µ\u003c\/td\u003e\n\u003ctd\u003e0.37mm\u003c\/td\u003e\n\u003ctd\u003e0.5MΩ\u003c\/td\u003e\n\u003ctd\u003e1-2µ\u003c\/td\u003e\n\u003ctd\u003eDeep brain studies\u003c\/td\u003e\n\u003ctd\u003ePackage of 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePlatinum Iridium Profile C, 305 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%;\" colspan=\"2\"\u003e\n\u003ch2\u003ePROS\u003c\/h2\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 11%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/lower-concomitant-impedance_4afc781a-9a78-426c-b98a-463cb975c84b.jpg?v=1765949521\" alt=\"lower concomitant impedance\" width=\"100\" height=\"100\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: #0081c2;\"\u003eLower Concomitant Impedance\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThis probe has lower concomitant impedance compared with tungsten and stainless steel.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 11%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/higher-charge-_transfer-capacity_3a0bfe49-b516-4238-8975-1b646b9e1a77.jpg?v=1765949527\" alt=\"higher charge transfer capacity\" width=\"100\" height=\"100\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: #0081c2;\"\u003eHigher Charge Transfer Capacity\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eMaking it perfect for microstimulation, Pt-Ir electrodes have a higher charge transfer capacity compared with tungsten and stainless steel.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 11%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/improved-electrochemical-stability_0f30f816-18f5-4a9a-80fd-c5014282c331.jpg?v=1765949534\" alt=\"improved electrochemical stability\" width=\"100\" height=\"100\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: #0081c2;\"\u003eImproved Electrochemical Stability\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003ePt-Ir offers improved electrochemical stability compared with tungsten and stainless steel.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 11%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/Perfect-microstimulation_6c4dd264-db7c-40a8-9eeb-865fced20987.jpg?v=1765949540\" alt=\"Perfect for microstimulation\" width=\"100\" height=\"100\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: #0081c2;\"\u003ePerfect for Microstimulation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003ePerfect for microstimulation, with excellent performance that ensures safe stimulation even with small probes.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 11%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/bend-_resistance_40c4ee43-ba23-4ae5-9a9a-40e61c03239a.jpg?v=1765949546\" alt=\"Iridium content improves bendresistance\" width=\"100\" height=\"100\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39%;\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: #0081c2;\"\u003eIridium Content Improves Bend Resistance\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eIridium content in the alloy increases the mechanical hardness, which stiffens the electrode to the point that the bend resistance comes close to that of tungsten.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 11%;\" colspan=\"2\"\u003e\n\u003ch2\u003eCONSIDERATIONS\u003c\/h2\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 11%;\" colspan=\"2\"\u003e\n\u003ch3\u003eAre you performing acute recordings or non-intensive chronic recordings?\u003c\/h3\u003e\n\u003cp\u003eYou may be able to use a tungsten probe instead. Platinum-iridium costs more than tungsten and stainless steel, which makes it less desirable for acute recording and non-intensive chronic recording.\u003c\/p\u003e\n\u003ch3\u003eWill you perform intensive stimulation protocols?\u003c\/h3\u003e\n\u003cp\u003eIntensive stimulation protocols could make platinum-iridium probes succeptible to corrosion and dissolution.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTypical User\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDeep brain studies\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKapton tubing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eKapton tubing, indicated by “KT” in the part number, extends from the connector to within 5 mm of the tip, providing stiffness and additional insulation to the electrode shaft. Kapton-clad electrodes are recommended when the electrode is to be inserted through a cannula for extra deep penetration.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/index.php?src=blog\u0026amp;srctype=detail\u0026amp;refno=19\u0026amp;category=Product%20Information\"\u003eSee Metal Microelectrode Selection Guide\u003c\/a\u003e\u003ca href=\"\/index.php?src=blog\u0026amp;srctype=detail\u0026amp;refno=19\u0026amp;category=Product%20Information\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/MetalMicroelectrodes_IS.pdf\" target=\"_self\"\u003eUsing Parylene Coated Metal Microelectrodes\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003ch2\u003eFAQ\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003eWhat length do I need?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eThe overall length of any electrode system is determined primarily on the depth of the tissue one wishes to record or stimulate and the micro-drive system being employed. Tungsten microprobes come in 76 mm or 125 mm (don’t see 125 um on WPI website) lengths or can be custom ordered in any length less than 5 inches. Platinum\/Iridium typically comes in two inch lengths and stainless steel in 51 mm lengths but either can also be specified in shorter lengths or in longer lengths using stainless steel and polyimide tubing. Because of the high expense of pure iridium it is always mounted in stainless steel and polyimide tubing and is typically 50 mm long.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003eWhat is the insulation thickness?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eAll electrodes except the 3 inch Extra Fine-F profile tungsten microprobe, that have a 1 micron coat of Parylene-C insulation, have 3 microns of Parylene-C. It has been proven that this thickness works best for most all electrode tip profiles we offer. We selected 3 microns to provide a sufficiently small tip profile for getting close to neural elements, ease of electrode insertion and to minimize attenuation for higher impedance electrodes. Attenuation of the signal can occur as a result of capacitive shunting when recording with higher impedance microprobes in deep structures, so additional insulation maybe required in the form of WPI’s KT, polyimide microprobes. The Extra Fine profile (ex. TM31C10) for the 3 inch tungsten electrodes provides an extremely fine microprobe tip which is excellent when recording from small densely packed cell structures.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003eWhat tip impedance or exposure do I need?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eBecause of our unique fabrication process and the special properties of Parylene-C we are able to expose any microprobe with microscopic precision and reproducibility. Each microprobe is individually exposed under a high power microscope, inspected and electrically characterized. Our microprobes have a lower impedance value for the same tip exposure as other commercially available electrodes. It is therefore recommended that those who have not used our electrodes before specify a range of impedance in order to select the best impedance value for their application. Also since we have been providing microprobes to researchers for over 30 years, we can provide expert advice in selecting the best electrode design for your experimental paradigm. Please contact us and provide information regarding your researcher’s requirements. There is no additional charge for specifying a range of impedance values for any box of microprobes.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003eWhat tip profile is best for my application?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eWe offer a variety of different tip alternatives for those that prefer a specialized electrode profile for their research. The tip selection can provide subtle yet important changes to the performance of the electrode, as described below. It is recommended that first time users consider experimenting with different tip profiles to determine which works best for their recording or stimulation protocols. A-Standard Our standard tip profile features a sharp yet robust point that offers versatile performance and an effective balance between penetration and durability. The most widely used tip profile, we recommend our standard tip for most neural recording applications, though it is also effective for most stimulation protocols. We employ an arc exposure method that provides precise and consistent performance as well as a very wide range of available impedances. While this method results in a small variability in impedance from electrode to electrode, most researchers find it very acceptable for their application. For those that need a more exact tip exposure, we offer a laser exposure service for a small premium. Please contact us if you feel this service is right for you. B-Blunted Our blunted electrodes are engineered to have a more rounded, bullet-shaped tip. For many applications the blunted tip can offer superior stimulation performance, as its shorter profile can lead to the electrode acting more as a point source and providing improved isolation. Many investigators feel that this profile both provides greater selectivity than the conventional sharper tip profiles and is more appropriate for higher-intensity stimulation protocols. Some investigators have also reported observations that the use of blunted tips leads to fewer occurrences of punctured cells. F-Extra fine Our extra-fine tip profile features a significantly sharper taper as well as a thinner insulation layer. This type of electrode is commonly used for shallow preparations where it is necessary to record from small tightly-packed cell populations, such as the striate layers of the visual and auditory cortices. Due to the very delicate nature of these tips, they are only available in tungsten electrodes, in 3-inch (76mm) length and both 0.003\" and 0.005\" (75 and 125 micron) shaft diameter. For penetrations greater than 4 mm in which the tip impedance is greater than 1.5 MΩ, we recommend that an additional layer of polyimide tubing be specified to reduce capacitive shunting and to increase the stiffness of the electrode. H-Heat Treated Our heat-treated electrodes are intended for those investigators who must penetrate their probes through tough membranes, such as the dura mater of larger mammals. By applying a heat source near the electrode tip under a microscope, we have the ability to provide an electrode with a more gradual tapering tip than our standard profile, while also toughening the polymer insulation near the tip. These modifications allow the electrode to be pushed through tough membranes easier and with less risk of tip and insulation damage.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003eProblems reading the impedance of your metal microelectrodes?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003col\u003e\r\n\u003cli\u003eCheck your impedance tester, maybe you are testing the impedance values at a different frequency than the 1 Kilohertz.\u003c\/li\u003e\r\n\u003cli\u003eCheck if your impedance tester doesn’t have a sample and hold circuit in which case the impedance is measured immediately upon pressing the test button and the impedance does not have a chance to stabilize.\u003c\/li\u003e\r\n\u003cli\u003eUsually the impedance will drop after a few minutes of the electrode being in the saline solution.\u003c\/li\u003e\r\n\u003cli\u003eSometimes the electrodes can oxidize increasing the impedance in which case we recommend passing about negative 3 to 4.5 volts across the electrode in saline to clean and de-oxidize the electrode.\u003c\/li\u003e\r\n\u003c\/ol\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003eWhat electrode configuration do I need?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eWe presently offer three different electrode configurations at this time, although we have fabricated many custom designs for customers in the past. As you observe what our part numbers look like for our probes, as seen under our Product section, you will notice they have a part number like WE30031.0A5. The 00 portion of the part number specifies the microprobe configuration. Monopolar Electrodes - 00 Implies no special mounting with the sharpened probe being insulated with Parylene-C, having the length, width, tip profile and impedance as specified in the tables for ordering your electrodes. Polyimide Tubing - PT Electrodes which have been mounted into polyimide tubing in order to increase the stiffness and provide additional insulation thickness. This mounting is typically recommended when fairly high impedance electrodes must penetrate deeper layers of the brain or spinal cord. ST Specifies our bipolar or stereotrodes. These electrodes when ordered with impedances less than 0.5 meohms are excellent for localizing stimulation current fields. Higher impedance stereotrodes are excellent for enhancing the isolation of single neural elements by simultaneous recording of multiple units on two closely spaced microelectrodes. The tip spacing is typically equal to the shaft diameter of one of the electrodes used in making the stereotrode. Different tip spacing is available upon request.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003eWhat type of connectors are used with our electrodes?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eThe 5482, 5483 pin connectors are attached to the distal end of our electrodes. You can purchase these connectors as well as the mating connector, M202, by clicking here and going to our Accessory Page. Many users prefer to use our electrodes without any connector, which is fine. We will simply remove the connectors for you if requested. There is no discount for this since the connectors are attached at the beginning our fabrication process.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003eWhat are the tip exposures for different electrode impedance values?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eTip exposures for Heat Tapered \"H\" tip profiles have approximately 15 to 20 percent MORE exposure. Tip exposures for Blunted \"B\" tip profiles have approximately 15 to 20 percent LESS exposure. Tip exposures for Extra Fine \"F\" tip profiles have approximately 10 to 15 percent MORE exposure.\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003eProblems reading the impedance of your metal microelectrodes?\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003col\u003e\r\n\u003cli\u003eCheck your impedance tester, maybe you are testing the impedance values at a different frequency than the 1 Kilohertz.\u003c\/li\u003e\r\n\u003cli\u003eCheck if your impedance tester doesn’t have a sample and hold circuit in which case the impedance is measured immediately upon pressing the test button and the impedance does not have a chance to stabilize.\u003c\/li\u003e\r\n\u003cli\u003eUsually the impedance will drop after a few minutes of the electrode being in the saline solution.\u003c\/li\u003e\r\n\u003cli\u003eSometimes the electrodes can oxidize increasing the impedance in which case we recommend passing about negative 3 to 4.5 volts across the electrode in saline to clean and de-oxidize the electrode.\u003c\/li\u003e\r\n\u003c\/ol\u003e\r\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266353827930,"sku":"PTM123B05KT","price":425.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/profilecsingleelectrodewpolymidetubing_fd160e2f-6815-4506-8682-9640e3075930.jpg?v=1766402763"}],"url":"https:\/\/wpiinc.com\/collections\/mono-platinum-iridium.oembed","provider":"World Precision Instruments","version":"1.0","type":"link"}