{"title":"Micropipette Holders","description":"\u003ch1\u003eMicropipette Holders and Half Cells\u003c\/h1\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003cp\u003eWPI’s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2mm pins or female 2mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl andCaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\n\u003ch3\u003eHints for selecting and ordering micropipette holders\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDetermine the required electrical connection on the holder. For example, if you wish to connect the holder to a 2mm pin, you should select a holder equipped with a 2mm jack. Most WPI probes require a holder equipped with a 2mm jack.\u003c\/li\u003e\n\u003cli\u003eDecide on the required alignment of the electrical connection (in-line with the glass pipette or at a right angle to it). Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/li\u003e\n\u003cli\u003eDetermine if you want to hold the glass pipette with a rubber gasket (MEH1S) or a screw-cap (MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/li\u003e\n\u003cli\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable, low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection.\u003c\/li\u003e\n\u003cli\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0mm O.D. and standard “syringe-style” luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\", 3\/32\", 1\/8\", 5\/32\" I.D.) are included with each luer-equipped holder.\u003c\/li\u003e\n\u003cli\u003eSome non-WPI preamplifiers or headstages cannot be mounted on micromanipulators. In such cases, a holder equipped with a rod (MEH8) permits the holder to be conveniently mounted on a micromanipulator.\u003c\/li\u003e\n\u003cli\u003eFinally, remember to specify the O.D. of the glass you will be using when you place your order.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eKeep in mind these general principles when considering the micropipettes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMEH6RF\/SF is designed primarily for use with the Model 900A Micropressure System.\u003c\/li\u003e\n\u003cli\u003eEHB1 is for use in electrode beveling.\u003c\/li\u003e\n\u003cli\u003eMEH3SW is for microtitration of chloride with a silver wire as the electrode and a solution of silver nitrate filling the holder.\u003c\/li\u003e\n\u003cli\u003eMPH models do not contain Ag\/AgCl half-cells and are used for pressure injection of substances through microelectrodes.\u003c\/li\u003e\n\u003cli\u003ePicoNozzle, used for pressure injection with PV800 Series PicoPumps, includes an MPH6S holder — which may also be used to couple a micropipette to a syringe.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\"\u003e\n\u003ctbody\u003e\n\u003ctr bgcolor=\"#d4d4d4\"\u003e\n\u003cth\u003e\u003cspan\u003e Order code\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eCustom Order\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eElectric Connection Angle\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eConnector\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eHalf-Cell\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003ePressure Port\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eScrew Cap\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDesigned for WPI Products\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4028\"\u003eEHB1\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003ctd\u003eMale\u003c\/td\u003e\n\u003ctd\u003eWire\u003c\/td\u003e\n\u003ctd\u003eNo Port\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eMBS, 48000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4029\"\u003eEHBF\u003c\/a\u003e\u003cbr\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003ctd\u003eFemale\u003c\/td\u003e\n\u003ctd\u003eWire\u003c\/td\u003e\n\u003ctd\u003eNo Port\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eMBS, 48000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eMBMPH5-7\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e----\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003eFemale Luer\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4033\"\u003e\u003cstrong\u003eMEH145\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e45°\u003c\/td\u003e\n\u003ctd\u003eMale\u003c\/td\u003e\n\u003ctd\u003ePellet\u003c\/td\u003e\n\u003ctd\u003eNo Port\u003c\/td\u003e\n\u003ctd\u003eNo Cap\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4034\"\u003e\u003cstrong\u003eMEH1F45 \u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e45°\u003c\/td\u003e\n\u003ctd\u003eFemale\u003c\/td\u003e\n\u003ctd\u003ePellet\u003c\/td\u003e\n\u003ctd\u003eNo Port\u003c\/td\u003e\n\u003ctd\u003eNo Cap\u003c\/td\u003e\n\u003ctd\u003e705, 773, 767, 721, FD223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4035\"\u003e\u003cstrong\u003eMEH1R\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRight\u003c\/td\u003e\n\u003ctd\u003eMale\u003c\/td\u003e\n\u003ctd\u003ePellet\u003c\/td\u003e\n\u003ctd\u003eNo Port\u003c\/td\u003e\n\u003ctd\u003eNo Cap\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4036\"\u003e\u003cstrong\u003eMEH1RF\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e Yes\u003c\/td\u003e\n\u003ctd\u003eRight\u003c\/td\u003e\n\u003ctd\u003eFemale\u003c\/td\u003e\n\u003ctd\u003ePellet\u003c\/td\u003e\n\u003ctd\u003eNo Port\u003c\/td\u003e\n\u003ctd\u003eNo Cap\u003c\/td\u003e\n\u003ctd\u003e705, 773, 767, 721, FD223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4037\"\u003e\u003cstrong\u003eMEH1S\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003ctd\u003eMale\u003c\/td\u003e\n\u003ctd\u003ePellet\u003c\/td\u003e\n\u003ctd\u003eNo Port\u003c\/td\u003e\n\u003ctd\u003eNo Cap\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4038\"\u003e\u003cstrong\u003eMEH1SF\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003ctd\u003eFemale\u003c\/td\u003e\n\u003ctd\u003ePellet\u003c\/td\u003e\n\u003ctd\u003eNo Port\u003c\/td\u003e\n\u003ctd\u003eNo Cap\u003c\/td\u003e\n\u003ctd\u003e705, 773, 767, 721, FD223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4039\"\u003e\u003cstrong\u003eMEH2R\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e Yes\u003c\/td\u003e\n\u003ctd\u003eRight\u003c\/td\u003e\n\u003ctd\u003eMale\u003c\/td\u003e\n\u003ctd\u003ePellet\u003c\/td\u003e\n\u003ctd\u003eMale Luer\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4040\"\u003e\u003cstrong\u003eMEH2RF\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e Yes\u003c\/td\u003e\n\u003ctd\u003eRight\u003c\/td\u003e\n\u003ctd\u003eFemale\u003c\/td\u003e\n\u003ctd\u003ePellet\u003c\/td\u003e\n\u003ctd\u003eMale Luer\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e705, 773, 767, 721, FD223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4041\"\u003e\u003cstrong\u003eMEH2RFW\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e Yes\u003c\/td\u003e\n\u003ctd\u003eRight\u003c\/td\u003e\n\u003ctd\u003eFemale\u003c\/td\u003e\n\u003ctd\u003eWire\u003c\/td\u003e\n\u003ctd\u003eMale Luer\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e705, 773, 767, 721, FD223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4042\"\u003e\u003cstrong\u003eMEH2RW\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e Yes\u003c\/td\u003e\n\u003ctd\u003eRight\u003c\/td\u003e\n\u003ctd\u003eMale\u003c\/td\u003e\n\u003ctd\u003eWire\u003c\/td\u003e\n\u003ctd\u003eMale Luer\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4043\"\u003e\u003cstrong\u003eMEH2S\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003ctd\u003eMale\u003c\/td\u003e\n\u003ctd\u003ePellet\u003c\/td\u003e\n\u003ctd\u003eMale Luer\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4044\"\u003e\u003cstrong\u003eMEH2SF\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003ctd\u003eFemale\u003c\/td\u003e\n\u003ctd\u003ePellet\u003c\/td\u003e\n\u003ctd\u003eMale Luer\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e705, 773, 767, 721, FD223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4045\"\u003e\u003cstrong\u003eMEH2SFW\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e Yes\u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003ctd\u003eFemale\u003c\/td\u003e\n\u003ctd\u003eWire\u003c\/td\u003e\n\u003ctd\u003eMale Luer\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e705, 773, 767, 721, FD223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4046\"\u003e\u003cstrong\u003eMEH2SW\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003ctd\u003eMale\u003c\/td\u003e\n\u003ctd\u003eWire\u003c\/td\u003e\n\u003ctd\u003eMale Luer\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4047\"\u003e\u003cstrong\u003eMEH345\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e45°\u003c\/td\u003e\n\u003ctd\u003eMale\u003c\/td\u003e\n\u003ctd\u003ePellet\u003c\/td\u003e\n\u003ctd\u003eNo Port\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4048\"\u003e\u003cstrong\u003eMEH3F45\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e Yes\u003c\/td\u003e\n\u003ctd\u003e45°\u003c\/td\u003e\n\u003ctd\u003eFemale\u003c\/td\u003e\n\u003ctd\u003ePellet\u003c\/td\u003e\n\u003ctd\u003eNo Port\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e705, 773, 767, 721, FD223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4049\"\u003e\u003cstrong\u003eMEH3FW45\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e Yes\u003c\/td\u003e\n\u003ctd\u003e45°\u003c\/td\u003e\n\u003ctd\u003eFemale\u003c\/td\u003e\n\u003ctd\u003eWire\u003c\/td\u003e\n\u003ctd\u003ePort\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4050\"\u003e\u003cstrong\u003eMEH3R\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRight\u003c\/td\u003e\n\u003ctd\u003eMale\u003c\/td\u003e\n\u003ctd\u003ePellet\u003c\/td\u003e\n\u003ctd\u003eNo Port\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4051\"\u003e\u003cstrong\u003eMEH3RF\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRight\u003c\/td\u003e\n\u003ctd\u003eFemale\u003c\/td\u003e\n\u003ctd\u003ePellet\u003c\/td\u003e\n\u003ctd\u003eNo Port\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e705, 773, 767, 721, FD223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4052\"\u003e\u003cstrong\u003eMEH3RFW\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e Yes\u003c\/td\u003e\n\u003ctd\u003eRight\u003c\/td\u003e\n\u003ctd\u003eFemale\u003c\/td\u003e\n\u003ctd\u003eWire\u003c\/td\u003e\n\u003ctd\u003eNo Port\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e705, 773, 767, 721, FD223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4053\"\u003e\u003cstrong\u003eMEH3RW\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e Yes\u003c\/td\u003e\n\u003ctd\u003eRight\u003c\/td\u003e\n\u003ctd\u003eMale\u003c\/td\u003e\n\u003ctd\u003eWire\u003c\/td\u003e\n\u003ctd\u003eNo Port\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4054\"\u003e\u003cstrong\u003eMEH3S\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003ctd\u003eMale\u003c\/td\u003e\n\u003ctd\u003ePellet\u003c\/td\u003e\n\u003ctd\u003eNo Port\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4055\"\u003e\u003cstrong\u003eMEH3SBW\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e Yes\u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003ctd\u003eBanana\u003c\/td\u003e\n\u003ctd\u003eWire\u003c\/td\u003e\n\u003ctd\u003eNo Port\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003eISO-80, ISO-DAM8A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4056\"\u003e\u003cstrong\u003eMEH3SF\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003ctd\u003eFemale\u003c\/td\u003e\n\u003ctd\u003ePellet\u003c\/td\u003e\n\u003ctd\u003eNo Port\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e705, 773, 767, 721, FD223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4057\"\u003e\u003cstrong\u003eMEH3SFW\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003ctd\u003eFemale\u003c\/td\u003e\n\u003ctd\u003eWire\u003c\/td\u003e\n\u003ctd\u003eNo Port\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e705, 773, 767, 721, FD223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4058\"\u003e\u003cstrong\u003eMEH3SW\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003ctd\u003eMale\u003c\/td\u003e\n\u003ctd\u003eWire\u003c\/td\u003e\n\u003ctd\u003eNo Port\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4059\"\u003e\u003cstrong\u003eMEH3W45\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e Yes\u003c\/td\u003e\n\u003ctd\u003e45°\u003c\/td\u003e\n\u003ctd\u003eMale\u003c\/td\u003e\n\u003ctd\u003eWire\u003c\/td\u003e\n\u003ctd\u003eNo Port\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e705, 773, 767, 721, FD223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4060\"\u003e\u003cstrong\u003eMEH6RF\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRight\u003c\/td\u003e\n\u003ctd\u003eFemale\u003c\/td\u003e\n\u003ctd\u003ePellet\u003c\/td\u003e\n\u003ctd\u003e2.0-mm Port\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e705, 773, 767, 721, FD223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4061\"\u003e\u003cstrong\u003eMEH6RFW\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e Yes\u003c\/td\u003e\n\u003ctd\u003eRight\u003c\/td\u003e\n\u003ctd\u003eFemale\u003c\/td\u003e\n\u003ctd\u003eWire\u003c\/td\u003e\n\u003ctd\u003e2.0-mm Port\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e705, 773, 767, 721, FD223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4062\"\u003e\u003cstrong\u003eMEH6SF\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003ctd\u003eFemale\u003c\/td\u003e\n\u003ctd\u003ePellet\u003c\/td\u003e\n\u003ctd\u003e2.0-mm Port\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e705, 773, 767, 721, FD223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4063\"\u003e\u003cstrong\u003eMEH6SFW\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e Yes\u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003ctd\u003eFemale\u003c\/td\u003e\n\u003ctd\u003eWire\u003c\/td\u003e\n\u003ctd\u003e2.0-mm Port\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e705, 773, 767, 721, FD223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4064\"\u003e\u003cstrong\u003eMEH7\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRight\u003c\/td\u003e\n\u003ctd\u003eMale\u003c\/td\u003e\n\u003ctd\u003ePellet\u003c\/td\u003e\n\u003ctd\u003e2.0-mm Port\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4065\"\u003e\u003cstrong\u003eMEH7W\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e Yes\u003c\/td\u003e\n\u003ctd\u003eRight\u003c\/td\u003e\n\u003ctd\u003eMale\u003c\/td\u003e\n\u003ctd\u003eWire\u003c\/td\u003e\n\u003ctd\u003e2.0-mm Port\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4066\"\u003e\u003cstrong\u003eMEH8\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRight\u003c\/td\u003e\n\u003ctd\u003eMale\u003c\/td\u003e\n\u003ctd\u003ePellet\u003c\/td\u003e\n\u003ctd\u003eNo Port\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4067\"\u003e\u003cstrong\u003eMEH900R\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRight\u003c\/td\u003e\n\u003ctd\u003eMale\u003c\/td\u003e\n\u003ctd\u003ePellet\u003c\/td\u003e\n\u003ctd\u003e2.0-mm Port\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e900A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4068\"\u003e\u003cstrong\u003eMEH900S\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003ctd\u003eMale\u003c\/td\u003e\n\u003ctd\u003ePellet\u003c\/td\u003e\n\u003ctd\u003e2.0-mm Port\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e900A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4069\"\u003e\u003cstrong\u003eMPH1\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003eFemale Luer\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4070\"\u003e\u003cstrong\u003eMPH3\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003eMale Luer\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4071\"\u003e\u003cstrong\u003eMPH4\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e2.0-mm Port\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4072\"\u003e\u003cstrong\u003eMPH6P\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eRight\u003c\/td\u003e\n\u003ctd\u003eMale\u003c\/td\u003e\n\u003ctd\u003ePellet\u003c\/td\u003e\n\u003ctd\u003eFemale Luer\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003ePiconozzle Kit (5430-XX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4073\"\u003e\u003cstrong\u003eMPH6R\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eRight\u003c\/td\u003e\n\u003ctd\u003eMale\u003c\/td\u003e\n\u003ctd\u003eWire\u003c\/td\u003e\n\u003ctd\u003eFemale Luer\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003ePiconozzle Kit (5430-XX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.wpi-europe.com\/products\/glass\/micropipette-holders.aspx#productlistitem4074\"\u003e\u003cstrong\u003eMPH6S\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003eFemale Luer\u003c\/td\u003e\n\u003ctd\u003ew\/Cap\u003c\/td\u003e\n\u003ctd\u003ePiconozzle Kit (5430-XX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","products":[{"product_id":"5373-low-noise-cable-for-microelectrode-holder-a-pin-jack-b-pin-jack","title":"Low-Noise Cable for Microelectrode Holder, A: pin\/jack, B: pin\/jack","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eConnector A: Combination pin\/jack\u003c\/li\u003e\r\n\u003cli\u003eConnector B: Combination pin\/jack\u003c\/li\u003e\r\n\u003cli\u003eCable: 2 ft (0.6 m)\u003c\/li\u003e\r\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42262670770266,"sku":"5373","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/5373_0bc0a1cd-e7fd-43cf-b7b2-767b48c57e80.jpg?v=1766392535"},{"product_id":"5374-low-noise-cable-for-microelectrode-holder-a-bnc-male-b-pin","title":"Low-noise cable for Microelectrode Holder, A: BNC (male), B: pin","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eConnector A: BNC (male)\u003c\/li\u003e\n\u003cli\u003eConnector B: 2 mm gold pin\u003c\/li\u003e\n\u003cli\u003eCable: 4 ft (1.2 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable id=\"table006\" class=\"Basic-Table TableOverride-1\" style=\"height: 684px;\" width=\"717\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-16\" style=\"background-color: #0081c2;\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-63\"\u003e\n\u003cp class=\"Table-Row-2\"\u003e\u003cspan class=\"Bold\" style=\"color: #ffffff;\"\u003eOrder code\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-63\"\u003e\n\u003cp class=\"Table-Row-2\"\u003e\u003cspan class=\"Bold\" style=\"color: #ffffff;\"\u003eAPPLICATION\/DESCRIPTION\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-63\"\u003e\n\u003cp class=\"Table-Row-2\"\u003e\u003cspan class=\"Bold\" style=\"color: #ffffff;\"\u003eCONNECTOR A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-63\"\u003e\n\u003cp class=\"Table-Row-2\"\u003e\u003cspan class=\"Bold\" style=\"color: #ffffff;\"\u003eCON­NEC­TOR B\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-63\"\u003e\n\u003cp class=\"Table-Row-2\"\u003e\u003cspan class=\"Bold\" style=\"color: #ffffff;\"\u003eCABLE LENGTH\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-27\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003ca href=\"\/products\/var-2851-bnc-to-bnc-cable\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e2851\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eStandard BNC cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003e6 ft (1.8 m)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-27\" style=\"border-width: 1px; border-color: #e4e4e4; background-color: #e4e4e4;\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003ca href=\"\/5374-low-noise-cable-for-microelectrode-holder-a-bnc-male-b-pin\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e5374\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eLow-noise cable for microelectrode holders\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003e2 mm gold pin\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003e4 ft (1.2 m)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-16\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003ca href=\"\/5375-low-noise-cable-for-microelectrode-holder-a-bnc-male-b-jack\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e5375\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eLow-noise cable for microelectrode holders\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003e2 mm gold jack\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003e4 ft (1.2 m)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-27\" style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003ca href=\"\/13324-13324-adapter-dual-banana-bnc\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e13324\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eAdapter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eDouble-banana (female)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003enone\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-16\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003ca href=\"\/13347-bnc-to-double-banana-connector\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e13347\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eISO2 (chart recorder adapter)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eDouble-banana (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (female)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003enone\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-27\" style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003ca href=\"\/13451-adapter-iso-dam8\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e13451\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eAdapter: Iso-DAM, Iso-DAM8\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (female)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003etwo 2 mm pins\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003e6 in. (15 cm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-16\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003ca href=\"\/13854-bnc-t-connector-male-to-female\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e13854\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC T-connector, male to:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (female)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (female)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003enone\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-27\" style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003ca href=\"\/14254-bnc-straight-adapter\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e14254\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC Straight Adapter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (female)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (female)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003enone\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-16\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e\u003ca href=\"\/var-2851-bnc-to-bnc-cable\"\u003e\u003c\/a\u003e\u003ca href=\"\/var-2851-bnc-to-bnc-cable\"\u003e500184\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eStandard BNC Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003e10 ft (3 m)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-27\" style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003ca href=\"\/500256-bnc-right-angle-adapter\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e500256\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC Right Angle Adapter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (female)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003enone\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-16\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e\u003ca href=\"\/var-2851-bnc-to-bnc-cable\"\u003e\u003c\/a\u003e\u003ca href=\"\/var-2851-bnc-to-bnc-cable\"\u003e500257\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eStandard BNC Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003e6 in. (15 cm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-27\" style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003ca href=\"\/500258-500258-bnc-to-bnc-cable-12-30cm\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e500258\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eStandard BNC Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003e12 in. (30 cm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-16\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e\u003ca href=\"\/var-2851-bnc-to-bnc-cable\"\u003e500259\u003c\/a\u003e\u003ca href=\"\/var-2851-bnc-to-bnc-cable\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eStandard BNC Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003e18 in. (46 cm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-27\" style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-66\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e\u003ca\u003e\u003c\/a\u003e\u003ca href=\"\/cbl102-dam-series-pm-series\"\u003eCBL102\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-66\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eDAM Series, PM Series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-66\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003e3.5 mmMiniPhone plug\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-66\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-66\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003e6 ft (1.8 m)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:details --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42262670868570,"sku":"5374","price":87.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/5374_812c2086-7c74-4e33-b600-5b5bd0a0ed16.jpg?v=1766392544"},{"product_id":"5375-low-noise-cable-for-microelectrode-holder-a-bnc-male-b-jack","title":"Low-noise cable for Microelectrode Holder, A: BNC (male), B: jack","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eConnector A: BNC (male)\u003c\/li\u003e\n\u003cli\u003eConnector B: 2 mm gold jack\u003c\/li\u003e\n\u003cli\u003eCable: 4 ft (1.2 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable id=\"table006\" class=\"Basic-Table TableOverride-1\" style=\"height: 684px;\" width=\"717\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-16\" style=\"background-color: #0081c2;\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-63\"\u003e\n\u003cp class=\"Table-Row-2\"\u003e\u003cspan class=\"Bold\" style=\"color: #ffffff;\"\u003eOrder code\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-63\"\u003e\n\u003cp class=\"Table-Row-2\"\u003e\u003cspan class=\"Bold\" style=\"color: #ffffff;\"\u003eAPPLICATION\/DESCRIPTION\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-63\"\u003e\n\u003cp class=\"Table-Row-2\"\u003e\u003cspan class=\"Bold\" style=\"color: #ffffff;\"\u003eCONNECTOR A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-63\"\u003e\n\u003cp class=\"Table-Row-2\"\u003e\u003cspan class=\"Bold\" style=\"color: #ffffff;\"\u003eCON­NEC­TOR B\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-63\"\u003e\n\u003cp class=\"Table-Row-2\"\u003e\u003cspan class=\"Bold\" style=\"color: #ffffff;\"\u003eCABLE LENGTH\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-27\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003ca href=\"\/var-2851-bnc-to-bnc-cable\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e2851\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eStandard BNC cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003e6 ft (1.8 m)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-27\" style=\"border-width: 1px; border-color: #e4e4e4; background-color: #e4e4e4;\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003ca href=\"\/5374-low-noise-cable-for-microelectrode-holder-a-bnc-male-b-pin\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e5374\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eLow-noise cable for microelectrode holders\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003e2 mm gold pin\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003e4 ft (1.2 m)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-16\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003ca href=\"\/5375-low-noise-cable-for-microelectrode-holder-a-bnc-male-b-jack\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e5375\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eLow-noise cable for microelectrode holders\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003e2 mm gold jack\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003e4 ft (1.2 m)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-27\" style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003ca href=\"\/13324-13324-adapter-dual-banana-bnc\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e13324\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eAdapter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eDouble-banana (female)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003enone\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-16\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003ca href=\"\/13347-bnc-to-double-banana-connector\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e13347\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eISO2 (chart recorder adapter)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eDouble-banana (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (female)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003enone\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-27\" style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003ca href=\"\/13451-adapter-iso-dam8\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e13451\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eAdapter: Iso-DAM, Iso-DAM8\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (female)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003etwo 2 mm pins\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003e6 in. (15 cm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-16\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003ca href=\"\/13854-bnc-t-connector-male-to-female\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e13854\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC T-connector, male to:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (female)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (female)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003enone\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-27\" style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003ca href=\"\/14254-bnc-straight-adapter\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e14254\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC Straight Adapter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (female)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (female)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003enone\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-16\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003ca href=\"\/var-2851-bnc-to-bnc-cable\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e500184\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eStandard BNC Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003e10 ft (3 m)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-27\" style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003ca href=\"\/500256-bnc-right-angle-adapter\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e500256\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC Right Angle Adapter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (female)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003enone\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-16\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003ca href=\"\/var-2851-bnc-to-bnc-cable\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e500257\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eStandard BNC Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003e6 in. (15 cm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-27\" style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003ca href=\"\/500258-500258-bnc-to-bnc-cable-12-30cm\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e500258\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eStandard BNC Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003e12 in. (30 cm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-16\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003ca href=\"\/var-2851-bnc-to-bnc-cable\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003e500259\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eStandard BNC Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-65\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003e18 in. (46 cm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"Basic-Table _idGenTableRowColumn-27\" style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd class=\"Basic-Table CellOverride-66\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003ca href=\"\/cbl102-dam-series-pm-series\"\u003e\u003cstrong\u003e\u003cspan class=\"CharOverride-41\"\u003eCBL102\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-66\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eDAM Series, PM Series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-66\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003e3.5 mmMiniPhone plug\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-66\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003eBNC (male)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Basic-Table CellOverride-66\"\u003e\n\u003cp class=\"Basic-Paragraph\"\u003e\u003cspan class=\"CharOverride-41\"\u003e6 ft (1.8 m)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/section:details --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42262671032410,"sku":"5375","price":80.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/5375_1_5dd0c99d-ebb7-40d5-93db-2e862f3db9de.jpg?v=1766392554"},{"product_id":"13620-low-noise-cable-for-microelectrode-holder-a-pin-b-jack","title":"Low-noise cable for Microelectrode Holder, A : pin,  B : jack","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eConnector A: 2 mm gold pin\u003c\/li\u003e\r\n\u003cli\u003eConnector B: 2 mm gold jack\u003c\/li\u003e\r\n\u003cli\u003eCable: 2 ft (0.6 m)\u003c\/li\u003e\r\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42262688137306,"sku":"13620","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/13620-9901_f50930dc-9b19-41a7-931a-022c3664774f.jpg?v=1766392839"},{"product_id":"ehb1-microelectrode-holder-straight-male-connector","title":"Microelectrode Holder, Straight, Male Connector","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eMale Connector\u003c\/li\u003e\r\n\u003cli\u003eWire Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eNo Pressure Port\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eEBH1 is designed for use in electrode beveling and fits capillary glass from 1.0 to 2.0 mm outer diameters.\u003c\/p\u003e\r\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"syringe-style\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\", 3\/32\", 1\/8\", 5\/32\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eHolder Half Cells Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266127040602,"sku":"EHB1","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ehb1_2b5d12ed-5a27-4ab1-b072-dee1a15f10b1.jpg?v=1766397434"},{"product_id":"ehbf-microelectrode-holder-straight-female-connector","title":"Microelectrode Holder, straight, Female Connector","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFemale Connector\u003c\/li\u003e\n\u003cli\u003eWire Half-Cell\u003c\/li\u003e\n\u003cli\u003eNo Pressure Port\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDetails\u003c\/h2\u003e\n\u003cp\u003eAll holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. Please specify diameter of glass you are using when placing your order.\u003c\/p\u003e\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"syringe-style\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\", 3\/32\", 1\/8\", 5\/32\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eHolder Half Cells Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266127106138,"sku":"EHBF","price":143.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/ehbf_d228e5f2-86c3-4720-9455-47fbf860ccc4.jpg?v=1766397441"},{"product_id":"var-3781-microelectrode-holder-mph6s","title":"Microelectrode Holder (MPH6S)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFemale Luer\u003c\/li\u003e\n\u003cli\u003eScrew Cap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOptions\u003c\/h2\u003e\n\u003ctable style=\"height: 49px; width: 331px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #0081c2;\"\u003e\n\u003ctd style=\"text-align: center; width: 180px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 135px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: center;\"\u003e\n\u003ctd style=\"text-align: left; width: 180px;\"\u003e MPH6S10\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 135px;\"\u003e1.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd style=\"text-align: left; width: 180px;\"\u003e MPH6S12\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 135px;\"\u003e1.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"text-align: left; width: 180px;\"\u003e MPH6S15\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 135px;\"\u003e1.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd style=\"text-align: left; width: 180px;\"\u003e MPH6S20\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 135px;\"\u003e2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor use with these WPI Products: Piconozzle Kit (5430-XX)\u003c\/p\u003e\n\u003cp\u003eAll holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. Please specify diameter of glass you are using when placing your order.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard “syringe-style” luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eHolder\/Half-cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266268663898,"sku":"MPH6S10","price":83.0,"currency_code":"USD","in_stock":true},{"title":"1.2 mm","offer_id":42266268696666,"sku":"MPH6S12","price":83.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266268729434,"sku":"MPH6S15","price":83.0,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":42266268762202,"sku":"MPH6S20","price":83.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/mph6s_6d52d05e-74fb-4507-b57e-b315fff4eca8.jpg?v=1766400219"},{"product_id":"var-3783-microelectrode-holder-meh1r","title":"Microelectrode Holder (MEH1R)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eMale Connector\u003c\/li\u003e\r\n\u003cli\u003ePellet Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eNo Pressure Port, No Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"width: 334px; height: 123px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"width: 193.4px; text-align: center;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"width: 124.6px; text-align: center;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"width: 193.4px; text-align: left;\"\u003eMEH1R10\u003c\/td\u003e\r\n\u003ctd style=\"width: 124.6px; text-align: left;\"\u003e1.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"width: 193.4px; text-align: left;\"\u003eMEH1R12\u003c\/td\u003e\r\n\u003ctd style=\"width: 124.6px; text-align: left;\"\u003e1.2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eAll holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. Please specify diameter of glass you are using when placing your order.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eMounting on a Micromanipulator\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eSome non-WPI preamplifiers or headstages cannot be mounted on micromanipulators. In such cases, a holder equipped with a rod (e.g., MEH8) permits the holder to be conveniently mounted on a micromanipulator.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eholder-half-cells-im.pdf\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266268860506,"sku":"MEH1R10","price":82.0,"currency_code":"USD","in_stock":true},{"title":"1.2 mm","offer_id":42266268893274,"sku":"MEH1R12","price":82.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh1r_ee56b64b-f1ff-42be-9895-a26f24312e44.jpg?v=1766400238"},{"product_id":"var-3784-microelectrode-holder-meh1rf","title":"Microelectrode Holder (MEH1RF)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eFemale Connector\u003c\/li\u003e\r\n\u003cli\u003ePellet Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eNo Pressure Port, No Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMEH1RF10\u003c\/td\u003e\r\n\u003ctd\u003e1.0mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMEH1RF15\u003c\/td\u003e\r\n\u003ctd\u003e1.5mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eFor use with these WPI Products: SYS-705, SYS-773, 767, 721, FD223\u003c\/p\u003e\r\n\u003cp\u003eAll holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. Please specify diameter of glass you are using when placing your order.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eHolder\/Half Cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266268991578,"sku":"MEH1RF10","price":92.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266269024346,"sku":"MEH1RF15","price":92.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh1rf_8193f612-4e6a-4e86-8f04-52d87a9b0d6e.jpg?v=1766400252"},{"product_id":"var-3785-microelectrode-holder-meh1s","title":"Microelectrode Holder (MEH1S)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eMale Connector\u003c\/li\u003e\r\n\u003cli\u003ePellet Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eNo Pressure Port, No Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 49px; width: 279px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 138px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 125px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 138px;\"\u003eMEH1S10\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 125px;\"\u003e1.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 138px;\"\u003eMEH1S12\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 125px;\"\u003e1.2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #ffffff;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 138px;\"\u003eMEH1S15\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 125px;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 138px;\"\u003eMEH1S20\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 125px;\"\u003e2.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eAll holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. Please specify diameter of glass you are using when placing your order.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eMounting on a Micromanipulator\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eSome non-WPI preamplifiers or headstages cannot be mounted on micromanipulators. In such cases, a holder equipped with a rod (e.g., MEH8) permits the holder to be conveniently mounted on a micromanipulator.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eHolder\/Half-cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266269089882,"sku":"MEH1S10","price":92.0,"currency_code":"USD","in_stock":true},{"title":"1.2 mm","offer_id":42266269122650,"sku":"MEH1S12","price":92.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266269155418,"sku":"MEH1S15","price":92.0,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":42266269188186,"sku":"MEH1S20","price":92.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh1s_e955fd8f-fc8c-47cc-b5af-3c71ea5742ec.jpg?v=1766400267"},{"product_id":"var-3786-microelectrode-holder-meh1sf","title":"Microelectrode Holder (MEH1SF)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eFemale Connector\u003c\/li\u003e\r\n\u003cli\u003ePellet Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eNo Pressure Port, No Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 49px; width: 314px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 150.8px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 148.2px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 150.8px;\"\u003eMEH1SF10\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 148.2px;\"\u003e1.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 150.8px;\"\u003eMEH1SF12\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 148.2px;\"\u003e1.2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #ffffff;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 150.8px;\"\u003eMEH1SF15\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 148.2px;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 150.8px;\"\u003eMEH1SF20\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 148.2px;\"\u003e2.0 mm \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eFor use with these WPI Products: SYS-705, SYS-773, 767, 721, FD223\u003c\/p\u003e\r\n\u003cp\u003eAll holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. Please specify diameter of glass you are using when placing your order.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eHolder\/Half-cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266269253722,"sku":"MEH1SF10","price":92.0,"currency_code":"USD","in_stock":true},{"title":"1.2 mm","offer_id":42266269286490,"sku":"MEH1SF12","price":92.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266269319258,"sku":"MEH1SF15","price":92.0,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":42266269352026,"sku":"MEH1SF20","price":92.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh1sf_0152b73e-091d-4277-8555-7ab64b147660.jpg?v=1766400288"},{"product_id":"var-3787-microelectrode-holder-meh2r","title":"Microelectrode Holder (MEH2R)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eSize 1.0mm\u003c\/li\u003e\r\n\u003cli\u003eMale Connector\u003c\/li\u003e\r\n\u003cli\u003ePellet Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eMale Luer\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eAll holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. Please specify diameter of glass you are using when placing your order.\u003c\/p\u003e\r\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eMounting on a Micromanipulator\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eSome non-WPI preamplifiers or headstages cannot be mounted on micromanipulators. In such cases, a holder equipped with a rod (e.g., MEH8) permits the holder to be conveniently mounted on a micromanipulator.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eholder-half-cells-im.pdf\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266269450330,"sku":"MEH2R10","price":115.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh2r_d610d91e-49c8-4d94-9878-40cc17bf85a3.jpg?v=1766400305"},{"product_id":"var-3788-microelectrode-holder-meh2rf","title":"Microelectrode Holder (MEH2RF)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFemale Connector\u003c\/li\u003e\n\u003cli\u003ePellet Half-Cell\u003c\/li\u003e\n\u003cli\u003eMale Luer\u003c\/li\u003e\n\u003cli\u003eScrew Cap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOptions\u003c\/h2\u003e\n\u003ctable style=\"height: 116px; width: 293px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #0081c2;\"\u003e\n\u003ctd style=\"text-align: center; width: 175.2px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 103.2px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: center;\"\u003e\n\u003ctd style=\"text-align: left; width: 175.2px;\"\u003eMEH2RF10\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 103.2px;\"\u003e1.0mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd style=\"text-align: left; width: 175.2px;\"\u003eMEH2RF12\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 103.2px;\"\u003e1.2mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eDetails\u003c\/h2\u003e\n\u003cp\u003eFor use with these WPI Products: SYS-705, SYS-773, 767, 721, FD223\u003c\/p\u003e\n\u003cp\u003eAll holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. Please specify diameter of glass you are using when placing your order.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003eWPI's microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eThe care and use of Microelectrode Holder Half-Cells\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266270498906,"sku":"MEH2RF10","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh2rf_eec5a372-8780-4509-bd57-159e874dc6dc.jpg?v=1766400318"},{"product_id":"var-3789-microelectrode-holder-meh2rfw","title":"Microelectrode Holder (MEH2RFW)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\r\n\u003cli\u003eFemale Connector\u003c\/li\u003e\r\n\u003cli\u003eWire Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eMale Luer\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 116px; width: 250px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 149.6px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 85.6px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 149.6px;\"\u003eMEH2RFW10\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 85.6px;\"\u003e1.0mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 149.6px;\"\u003eMEH2RFW12\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 85.6px;\"\u003e1.2mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #ffffff;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 149.6px;\"\u003eMEH2RFW15\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 85.6px;\"\u003e1.5mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 149.6px;\"\u003eMEH2RFW20\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 85.6px;\"\u003e2.0mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI's microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHolder\/Half Cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266271678554,"sku":"MEH2RFW10","price":115.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266271711322,"sku":"MEH2RFW15","price":115.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh2rfw_b1d4b5ba-bacc-4814-a8e9-66170a33b63a.jpg?v=1766400330"},{"product_id":"var-3790-microelectrode-holder-meh2rw","title":"Microelectrode Holder (MEH2RW)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eMale Connector\u003c\/li\u003e\r\n\u003cli\u003eWire Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eMale Luer\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 107px; width: 304.8px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 156px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 132.8px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 156px;\"\u003eMEH2RW10\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 132.8px;\"\u003e1.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 156px;\"\u003eMEH2RW12\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 132.8px;\"\u003e1.2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 156px;\"\u003eMEH2RW15\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 132.8px;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI's microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eMounting on a Micromanipulator\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eSome non-WPI preamplifiers or headstages cannot be mounted on micromanipulators. In such cases, a holder equipped with a rod (e.g., MEH8) permits the holder to be conveniently mounted on a micromanipulator.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHolder\/Half Cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266272661594,"sku":"MEH2RW10","price":115.0,"currency_code":"USD","in_stock":true},{"title":"1.2 mm","offer_id":42266272596058,"sku":"MEH2RW12","price":115.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266272628826,"sku":"MEH2RW15","price":115.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh2rw_5b098c3e-5ba2-4c83-89e8-a01f10f8d51a.jpg?v=1766400348"},{"product_id":"var-3791-microelectrode-holder-meh2s","title":"Microelectrode Holder (MEH2S)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eMale Connector\u003c\/li\u003e\r\n\u003cli\u003ePellet Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eMale Luer\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 49px; width: 300px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 160px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 124px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 160px;\"\u003e MEH2S10\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 124px;\"\u003e1.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 160px;\"\u003e MEH2S12\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 124px;\"\u003e1.2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #ffffff;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 160px;\"\u003e MEH2S15\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 124px;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eMounting on a Micromanipulator\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eSome non-WPI preamplifiers or headstages cannot be mounted on micromanipulators. In such cases, a holder equipped with a rod (e.g., MEH8) permits the holder to be conveniently mounted on a micromanipulator.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eHolder\/Half-cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266273284186,"sku":"MEH2S10","price":99.0,"currency_code":"USD","in_stock":true},{"title":"1.2 mm","offer_id":42266273316954,"sku":"MEH2S12","price":99.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266273349722,"sku":"MEH2S15","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh2s_104b46ae-a98b-4952-8e9b-9db02c14dd88.jpg?v=1766400364"},{"product_id":"var-3792-microelectrode-holder-meh2sf","title":"Microelectrode Holder (MEH2SF)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eFemale Connector\u003c\/li\u003e\r\n\u003cli\u003ePellet Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eMale Luer\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 49px; width: 288px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 157.8px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 115.2px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 157.8px;\"\u003eMEH2SF10\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 115.2px;\"\u003e1.0 mm \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 157.8px;\"\u003eMEH2SF15\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 115.2px;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eHolder\/Half-cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266273972314,"sku":"MEH2SF10","price":195.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266273939546,"sku":"MEH2SF15","price":195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh2sf_811ee3c3-6967-4f84-804f-45fcf0a36464.jpg?v=1766400380"},{"product_id":"var-3793-microelectrode-holder-meh2sfw","title":"Microelectrode Holder (MEH2SFW)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eFemale Connector\u003c\/li\u003e\r\n\u003cli\u003eWire Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eMale Luer\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"width: 294.2px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 135px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 144.2px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center; background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 135px;\"\u003eMEH2SFW10\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 144.2px;\"\u003e1.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 135px;\"\u003eMEH2SFW15\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 144.2px;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 135px;\"\u003eMEH2SFW20\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 144.2px;\"\u003e2.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e  \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI's microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHolder\/Half Cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266274103386,"sku":"MEH2SFW10","price":115.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266274037850,"sku":"MEH2SFW15","price":115.0,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":42266274070618,"sku":"MEH2SFW20","price":115.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh2sfw_356d33d4-4e9f-45be-b0b4-4bee3ea3cdf5.jpg?v=1766400395"},{"product_id":"var-3794-microelectrode-holder-meh2sw","title":"Microelectrode Holder (MEH2SW)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eMale Connector\u003c\/li\u003e\r\n\u003cli\u003eWire Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eMale Luer\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 49px; width: 296px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 157px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 123px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 157px;\"\u003e MEH2SW10\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 123px;\"\u003e1.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 157px;\"\u003e MEH2SW12\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 123px;\"\u003e1.2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #ffffff;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 157px;\"\u003e MEH2SW15\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 123px;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 157px;\"\u003e MEH2SW20\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 123px;\"\u003e2.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style” luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eMounting on a Micromanipulator\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eSome non-WPI preamplifiers or headstages cannot be mounted on micromanipulators. In such cases, a holder equipped with a rod (e.g., MEH8) permits the holder to be conveniently mounted on a micromanipulator.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eHolder\/Half-cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266274168922,"sku":"MEH2SW10","price":115.0,"currency_code":"USD","in_stock":true},{"title":"1.2 mm","offer_id":42266274201690,"sku":"MEH2SW12","price":115.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266274234458,"sku":"MEH2SW15","price":115.0,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":42266274267226,"sku":"MEH2SW20","price":115.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh2sw_a328c655-14fa-4a2a-a684-22222807b3dc.jpg?v=1766400414"},{"product_id":"var-3795-microelectrode-holder-meh345","title":"Microelectrode Holder (MEH345)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\r\n\u003cli\u003eMale Connector\u003c\/li\u003e\r\n\u003cli\u003ePellet Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eNo Pressure Port\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"width: 326px; height: 120px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"width: 188.55px; text-align: center;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"width: 121.45px; text-align: center;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"width: 188.55px; text-align: left;\"\u003e MEH34510\u003c\/td\u003e\r\n\u003ctd style=\"width: 121.45px; text-align: left;\"\u003e1.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"width: 188.55px; text-align: left;\"\u003e MEH34512\u003c\/td\u003e\r\n\u003ctd style=\"width: 121.45px; text-align: left;\"\u003e1.2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #ffffff;\"\u003e\r\n\u003ctd style=\"width: 188.55px; text-align: left;\"\u003e MEH34515\u003c\/td\u003e\r\n\u003ctd style=\"width: 121.45px; text-align: left;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"width: 188.55px; text-align: left;\"\u003e MEH34520\u003c\/td\u003e\r\n\u003ctd style=\"width: 121.45px; text-align: left;\"\u003e2.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eMounting on a Micromanipulator\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eSome non-WPI preamplifiers or headstages cannot be mounted on micromanipulators. In such cases, a holder equipped with a rod (e.g., MEH8) permits the holder to be conveniently mounted on a micromanipulator.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eholder-half-cells-im.pdf\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266274398298,"sku":"MEH34510","price":115.0,"currency_code":"USD","in_stock":true},{"title":"1.2 mm","offer_id":42266274431066,"sku":"MEH34512","price":115.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266274463834,"sku":"MEH34515","price":156.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh345_de3f55b8-f3d8-4635-b101-612d6357f7b9.jpg?v=1766400433"},{"product_id":"var-3796-microelectrode-holder-meh3f45","title":"Microelectrode Holder (MEH3F45)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eSize 1.5 mm\u003c\/li\u003e\r\n\u003cli\u003eFemale Connector\u003c\/li\u003e\r\n\u003cli\u003ePellet Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eNo Pressure Port\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003cli\u003e1.0mm available as a standard part \u003ca href=\"\/meh3f4510-microelectrode-holder-meh3f45-10mm-od\"\u003eMEH3F4510 (1.0mm)\u003c\/a\u003e\n\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eholder-half-cells-im.pdf\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.5 mm","offer_id":42266275512410,"sku":"MEH3F4515","price":156.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh3f45_7a236e1a-5694-4174-90d2-b5c7b97dce55.jpg?v=1766400449"},{"product_id":"var-3797-microelectrode-holder-meh3fw45","title":"Microelectrode Holder (MEH3FW45)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eFemale Connector\u003c\/li\u003e\r\n\u003cli\u003eWire Half-Cell\u003c\/li\u003e\r\n\u003cli\u003ePressure Port\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 91px; width: 304px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #ffffff;\"\u003e\r\n\u003ctd style=\"text-align: left;\"\u003e MEH3FW4515\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left;\"\u003e MEH3FW4520\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left;\"\u003e2.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI's microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eMounting on a Micromanipulator\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eSome non-WPI preamplifiers or headstages cannot be mounted on micromanipulators. In such cases, a holder equipped with a rod (e.g., MEH8) permits the holder to be conveniently mounted on a micromanipulator.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHolder\/Half Cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.5 mm","offer_id":42266275840090,"sku":"MEH3FW4515","price":111.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh3fw45_25a72517-47f9-45c9-92cd-5688a8e38bc7.jpg?v=1766400462"},{"product_id":"var-3798-microelectrode-holder-meh3r","title":"Microelectrode Holder (MEH3R)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\r\n\u003cli\u003eMale Connector\u003c\/li\u003e\r\n\u003cli\u003ePellet Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eNo Pressure Port\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 49px; width: 278px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 129px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 133px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 129px;\"\u003e MEH3R10\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 133px;\"\u003e1.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 129px;\"\u003e MEH3R12\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 133px;\"\u003e1.2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #ffffff;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 129px;\"\u003e MEH3R15\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 133px;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 129px;\"\u003e MEH3R20\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 133px;\"\u003e2.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eMounting on a Micromanipulator\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eSome non-WPI preamplifiers or headstages cannot be mounted on micromanipulators. In such cases, a holder equipped with a rod (e.g., MEH8) permits the holder to be conveniently mounted on a micromanipulator.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eThe care and use of Microelectrode Holder Half-Cells\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266276135002,"sku":"MEH3R10","price":177.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266276167770,"sku":"MEH3R15","price":177.0,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":42266276200538,"sku":"MEH3R20","price":177.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh3r_e1535597-ab5f-495a-b335-3dd6c59e07ed.jpg?v=1766400477"},{"product_id":"var-3799-microelectrode-holder-meh3rf","title":"Microelectrode Holder (MEH3RF)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eFemale Connector\u003c\/li\u003e\r\n\u003cli\u003ePellet Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eNo Pressure Port\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 49px; width: 282px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 146px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 120px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center; background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 146px;\"\u003e MEH3RF10\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 120px;\"\u003e1.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #ffffff;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 146px;\"\u003e MEH3RF15\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 120px;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 146px;\"\u003e MEH3RF20\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 120px;\"\u003e2.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eThe care and use of Microelectrode Holder Half-Cells\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266276266074,"sku":"MEH3RF10","price":105.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266276298842,"sku":"MEH3RF15","price":105.0,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":42266276331610,"sku":"MEH3RF20","price":105.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh3rf_8714aade-52cd-46fd-82a8-98c13e8edbb3.jpg?v=1766400493"},{"product_id":"var-3800-microelectrode-holder-meh3rfw","title":"Microelectrode Holder (MEH3RFW)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eFemale Connector\u003c\/li\u003e\r\n\u003cli\u003eWire Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eNo Pressure Port\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 49px; width: 301px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 156.8px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 129.2px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 156.8px;\"\u003eMEH3RFW12\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 129.2px;\"\u003e1.2mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #ffffff;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 156.8px;\"\u003eMEH3RFW15\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 129.2px;\"\u003e1.5mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI's microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHolder\/Half Cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.2 mm","offer_id":42266276429914,"sku":"MEH3RFW12","price":96.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266276462682,"sku":"MEH3RFW15","price":96.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh3rfw_b87841cf-39d2-47da-8545-bfb9be560546.jpg?v=1766400510"},{"product_id":"var-3801-microelectrode-holder-meh3rw","title":"Microelectrode Holder (MEH3RW)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eMale Connector\u003c\/li\u003e\r\n\u003cli\u003eWire Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eNo Pressure Port\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 49px; width: 308px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 174px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 119px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 174px;\"\u003eMEH3RW10\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 119px;\"\u003e1.0mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"width: 174px;\"\u003eMEH3RW15\u003c\/td\u003e\r\n\u003ctd style=\"width: 119px;\"\u003e1.5mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI's microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eMounting on a Micromanipulator\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eSome non-WPI preamplifiers or headstages cannot be mounted on micromanipulators. In such cases, a holder equipped with a rod (e.g., MEH8) permits the holder to be conveniently mounted on a micromanipulator.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHolder\/Half Cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266276528218,"sku":"MEH3RW10","price":96.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266276560986,"sku":"MEH3RW15","price":96.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh3rw_0d80dfec-163f-43e5-93cb-fe28e1c9d885.jpg?v=1766400524"},{"product_id":"var-3802-microelectrode-holder-meh3s","title":"Microelectrode Holder (MEH3S)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\r\n\u003cli\u003eMale Connector\u003c\/li\u003e\r\n\u003cli\u003ePellet Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eNo Pressure Port\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 49px; width: 304px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 146px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 142px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 146px;\"\u003e MEH3S10\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 142px;\"\u003e1.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 146px;\"\u003e MEH3S12\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 142px;\"\u003e1.2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #ffffff;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 146px;\"\u003e MEH3S15\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 142px;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 146px;\"\u003e MEH3S20\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 142px;\"\u003e2.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eMounting on a Micromanipulator\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eSome non-WPI preamplifiers or headstages cannot be mounted on micromanipulators. In such cases, a holder equipped with a rod (e.g., MEH8) permits the holder to be conveniently mounted on a micromanipulator.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eHolder\/Half-cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266276659290,"sku":"MEH3S10","price":96.0,"currency_code":"USD","in_stock":true},{"title":"1.2 mm","offer_id":42266276692058,"sku":"MEH3S12","price":96.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266276724826,"sku":"MEH3S15","price":96.0,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":42266276757594,"sku":"MEH3S20","price":96.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh3s_f5b0aee3-2e91-4930-bbe7-f747df24adac.jpg?v=1766400541"},{"product_id":"var-3804-microelectrode-holder-meh3sbw","title":"Microelectrode Holder (MEH3SBW)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eBanana Connector\u003c\/li\u003e\r\n\u003cli\u003eWire Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eNo Pressure Port\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 49px; width: 303px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 150.6px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 137.4px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 150.6px;\"\u003eMEH3SBW10\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 137.4px;\"\u003e1.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd style=\"text-align: left; width: 150.6px;\"\u003eMEH3SBW15\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 137.4px;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI's microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eHolder\/Half Cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266277675098,"sku":"MEH3SBW10","price":200.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266277707866,"sku":"MEH3SBW15","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh3sbw_7f12d979-935b-4d40-89bd-059a01c6d96d.jpg?v=1766400559"},{"product_id":"var-3805-microelectrode-holder-meh3sf","title":"Microelectrode Holder (MEH3SF)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\r\n\u003cli\u003eFemale Connector\u003c\/li\u003e\r\n\u003cli\u003ePellet Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eNo Pressure Port\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 49px; width: 324px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 170.8px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 138.2px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 170.8px;\"\u003e MEH3SF10\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 138.2px;\"\u003e1.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 170.8px;\"\u003e MEH3SF12\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 138.2px;\"\u003e1.2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #ffffff;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 170.8px;\"\u003e MEH3SF15\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 138.2px;\"\u003e 1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 170.8px;\"\u003e MEH3SF20\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 138.2px;\"\u003e 2.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eHolder\/Half-cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266277773402,"sku":"MEH3SF10","price":140.0,"currency_code":"USD","in_stock":true},{"title":"1.2 mm","offer_id":42266277806170,"sku":"MEH3SF12","price":140.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266277838938,"sku":"MEH3SF15","price":140.0,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":42266277871706,"sku":"MEH3SF20","price":140.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh3sf_a929d3ac-00f5-45c0-8c6f-3d2422dd98db.jpg?v=1766400574"},{"product_id":"var-3806-microelectrode-holder-meh3sfw","title":"Microelectrode Holder (MEH3SFW)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\r\n\u003cli\u003eFemale Connector\u003c\/li\u003e\r\n\u003cli\u003eWire Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eNo Pressure Port\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 96px; width: 366px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 206.2px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 146.8px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 206.2px;\"\u003eMEH3SFW10\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 146.8px;\"\u003e1.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 206.2px;\"\u003eMEH3SFW12\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 146.8px;\"\u003e1.2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #ffffff;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 206.2px;\"\u003eMEH3SFW15\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 146.8px;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 206.2px;\"\u003eMEH3SFW20\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 146.8px;\"\u003e2.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI's microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHolder\/Half Cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266277937242,"sku":"MEH3SFW10","price":82.0,"currency_code":"USD","in_stock":true},{"title":"1.2 mm","offer_id":42266277970010,"sku":"MEH3SFW12","price":82.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266278002778,"sku":"MEH3SFW15","price":82.0,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":42266278035546,"sku":"MEH3SFW20","price":82.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh3sfw_9ed271dc-cb95-4072-aa55-7c950fcf393c.jpg?v=1766400592"},{"product_id":"var-3807-microelectrode-holder-meh3sw","title":"Microelectrode Holder (MEH3SW)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eMale Connector\u003c\/li\u003e\r\n\u003cli\u003eWire Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eNo Pressure Port\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 96px; width: 331px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 194.4px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 122.6px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 194.4px;\"\u003eMEH3SW10\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 122.6px;\"\u003e1.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 194.4px;\"\u003eMEH3SW12\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 122.6px;\"\u003e1.2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #ffffff;\"\u003e\r\n\u003ctd style=\"width: 194.4px;\"\u003eMEH3SW15\u003c\/td\u003e\r\n\u003ctd style=\"width: 122.6px;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"width: 194.4px;\"\u003eMEH3SW20\u003c\/td\u003e\r\n\u003ctd style=\"width: 122.6px;\"\u003e2.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI's microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eMounting on a Micromanipulator\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eSome non-WPI preamplifiers or headstages cannot be mounted on micromanipulators. In such cases, a holder equipped with a rod (e.g., MEH8) permits the holder to be conveniently mounted on a micromanipulator.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHolder\/Half Cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266278101082,"sku":"MEH3SW10","price":82.0,"currency_code":"USD","in_stock":true},{"title":"1.2 mm","offer_id":42266278133850,"sku":"MEH3SW12","price":82.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266278166618,"sku":"MEH3SW15","price":82.0,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":42266278199386,"sku":"MEH3SW20","price":82.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh3sw_05c69791-cf3a-467f-8804-0329847a8516.jpg?v=1766400613"},{"product_id":"var-3808-microelectrode-holder-meh3w45","title":"Microelectrode Holder (MEH3W45)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eMale Connector\u003c\/li\u003e\r\n\u003cli\u003eWire Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eNo Pressure Port\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"width: 309px; height: 118px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"width: 180.49px; text-align: center;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"width: 112.51px; text-align: center;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #ffffff;\"\u003e\r\n\u003ctd style=\"width: 180.49px; text-align: left;\"\u003eMEH3W4515\u003c\/td\u003e\r\n\u003ctd style=\"width: 112.51px; text-align: left;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"width: 180.49px; text-align: left;\"\u003eMEH3W4520\u003c\/td\u003e\r\n\u003ctd style=\"width: 112.51px; text-align: left;\"\u003e2.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI's microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHolder\/Half Cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.5 mm","offer_id":42266278264922,"sku":"MEH3W4515","price":82.0,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":42266278297690,"sku":"MEH3W4520","price":82.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh3w45_bb0ef81e-624b-46f6-8f50-aec0c9daec9b.jpg?v=1766400631"},{"product_id":"var-3809-microelectrode-holder-meh6rf","title":"Microelectrode Holder (MEH6RF)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eFemale Connector\u003c\/li\u003e\r\n\u003cli\u003ePellet Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eSize 1.0 mm\u003c\/li\u003e\r\n\u003cli\u003e2.0mm Pressure Port\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eThe care and use of Microelectrode Holder Half-Cells\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266279149658,"sku":"MEH6RF10","price":177.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh6rf_3966d175-5282-442d-bb02-cbcbca70ee0a.jpg?v=1766400645"},{"product_id":"var-3810-microelectrode-holder-meh6rfw","title":"Microelectrode Holder (MEH6RFW)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eFemale Connector\u003c\/li\u003e\r\n\u003cli\u003eWire Half-Cell\u003c\/li\u003e\r\n\u003cli\u003e2.0mm Pressure Port\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 49px; width: 309px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 142.8px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 151.2px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 142.8px;\"\u003eMEH6RFW10\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 151.2px;\"\u003e1.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 142.8px;\"\u003eMEH6RFW12\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 151.2px;\"\u003e1.2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 142.8px;\"\u003eMEH6RFW15\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 151.2px;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI's microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHolder\/Half Cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266279215194,"sku":"MEH6RFW10","price":82.0,"currency_code":"USD","in_stock":true},{"title":"1.2 mm","offer_id":42266279247962,"sku":"MEH6RFW12","price":82.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266279280730,"sku":"MEH6RFW15","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh6rfw_bcb4bf0c-1641-45f6-b7ed-ab2ab3fdb8b9.jpg?v=1766400658"},{"product_id":"var-3811-microelectrode-holder-meh6sf","title":"Microelectrode Holder (MEH6SF)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\r\n\u003cli\u003eFemale Connector\u003c\/li\u003e\r\n\u003cli\u003ePellet Half-Cell\u003c\/li\u003e\r\n\u003cli\u003e2.0mm Pressure Port\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 120px; width: 392px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 223.4px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 154.6px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 223.4px;\"\u003e MEH6SF10\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 154.6px;\"\u003e1.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 223.4px;\"\u003e MEH6SF12\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 154.6px;\"\u003e1.2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #ffffff;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 223.4px;\"\u003e MEH6SF15\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 154.6px;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 223.4px;\"\u003e MEH6SF20\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 154.6px;\"\u003e2.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHolder\/Half-cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266280034394,"sku":"MEH6SF10","price":127.0,"currency_code":"USD","in_stock":true},{"title":"1.2 mm","offer_id":42266280067162,"sku":"MEH6SF12","price":127.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266280099930,"sku":"MEH6SF15","price":127.0,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":42266280132698,"sku":"MEH6SF20","price":127.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh6sf_21e4d496-6e18-493f-bb27-dfc937f64fc2.jpg?v=1766400677"},{"product_id":"var-3813-microelectrode-holder-meh7","title":"Microelectrode Holder (MEH7)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMale Connector\u003c\/li\u003e\n\u003cli\u003ePellet Half-Cell\u003c\/li\u003e\n\u003cli\u003e2.0mm Pressure Port\u003c\/li\u003e\n\u003cli\u003eScrew Cap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOptions\u003c\/h2\u003e\n\u003ctable style=\"height: 49px; width: 307px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #0081c2;\"\u003e\n\u003ctd style=\"text-align: center; width: 127px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 164px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: center;\"\u003e\n\u003ctd style=\"text-align: left; width: 127px;\"\u003e MEH710\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 164px;\"\u003e1.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd style=\"text-align: left; width: 127px;\"\u003e MEH712\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 164px;\"\u003e1.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"text-align: left; width: 127px;\"\u003e MEH715\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 164px;\"\u003e1.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd style=\"text-align: left; width: 127px;\"\u003e MEH720\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 164px;\"\u003e2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eDetails\u003c\/h2\u003e\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMounting on a Micromanipulator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSome non-WPI preamplifiers or headstages cannot be mounted on micromanipulators. In such cases, a holder equipped with a rod (e.g., MEH8) permits the holder to be conveniently mounted on a micromanipulator.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eThe care and use of Microelectrode Holder Half-Cells\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266280198234,"sku":"MEH710","price":142.0,"currency_code":"USD","in_stock":true},{"title":"1.2 mm","offer_id":42266280231002,"sku":"MEH712","price":142.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266280263770,"sku":"MEH715","price":142.0,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":42266280296538,"sku":"MEH720","price":142.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh7_326c23fc-54d6-4ce1-af58-3b3e3a01c9bd.jpg?v=1766400696"},{"product_id":"var-3814-microelectrode-holder-meh7w","title":"Microelectrode Holder (MEH7W)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eMale Connector\u003c\/li\u003e\r\n\u003cli\u003eWire Half-Cell\u003c\/li\u003e\r\n\u003cli\u003e2.0mm Pressure Port\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 49px; width: 287px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 131px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 140px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 131px;\"\u003eMEH7W10\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 140px;\"\u003e1.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 131px;\"\u003eMEH7W12\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 140px;\"\u003e1.2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 131px;\"\u003eMEH7W15\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 140px;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI's microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eMounting on a Micromanipulator\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eSome non-WPI preamplifiers or headstages cannot be mounted on micromanipulators. In such cases, a holder equipped with a rod (e.g., MEH8) permits the holder to be conveniently mounted on a micromanipulator.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eHolder\/Half Cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266280394842,"sku":"MEH7W10","price":82.0,"currency_code":"USD","in_stock":true},{"title":"1.2 mm","offer_id":42266280362074,"sku":"MEH7W12","price":82.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266280427610,"sku":"MEH7W15","price":82.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh7w_4f073aa1-6ea3-4cba-a1d0-871553e09132.jpg?v=1766400715"},{"product_id":"var-3815-microelectrode-holder-meh8","title":"Microelectrode Holder (MEH8)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMale Connector\u003c\/li\u003e\n\u003cli\u003ePellet Half-Cell\u003c\/li\u003e\n\u003cli\u003eNo Pressure Port\u003c\/li\u003e\n\u003cli\u003eScrew Cap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOptions\u003c\/h2\u003e\n\u003ctable style=\"height: 49px; width: 319px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #0081c2;\"\u003e\n\u003ctd style=\"text-align: center; width: 163px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 140px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: center;\"\u003e\n\u003ctd style=\"text-align: left; width: 163px;\"\u003e MEH810\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 140px;\"\u003e1.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd style=\"text-align: left; width: 163px;\"\u003e MEH812\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 140px;\"\u003e1.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"text-align: left; width: 163px;\"\u003e MEH815\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 140px;\"\u003e1.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\n\u003ctd style=\"text-align: left; width: 163px;\"\u003e MEH820\u003c\/td\u003e\n\u003ctd style=\"text-align: left; width: 140px;\"\u003e2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eDetails\u003c\/h2\u003e\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style' luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMounting on a Micromanipulator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSome non-WPI preamplifiers or headstages cannot be mounted on micromanipulators. In such cases, a holder equipped with a rod (e.g., MEH8) permits the holder to be conveniently mounted on a micromanipulator.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eThe care and use of Microelectrode Holder Half-Cells\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266280493146,"sku":"MEH810","price":110.0,"currency_code":"USD","in_stock":true},{"title":"1.2 mm","offer_id":42266280525914,"sku":"MEH812","price":110.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266280558682,"sku":"MEH815","price":110.0,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":42266280591450,"sku":"MEH820","price":110.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh8_f398cda5-7a2d-4b3c-9e18-e5036e9bbe76.jpg?v=1766400731"},{"product_id":"var-3816-microelectrode-holder-meh900r","title":"Microelectrode Holder (MEH900R)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eMale Connector\u003c\/li\u003e\r\n\u003cli\u003ePellet Half-Cell\u003c\/li\u003e\r\n\u003cli\u003e2.0mm Pressure Port\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 120px; width: 356.2px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 171px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 170.2px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center; background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 171px;\"\u003e MEH900R10\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 170.2px;\"\u003e1.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #ffffff;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 171px;\"\u003e MEH900R15\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 170.2px;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 171px;\"\u003e MEH900R20\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 170.2px;\"\u003e2.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eThe care and use of Microelectrode Holder Half-Cells\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266280722522,"sku":"MEH900R10","price":101.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266280755290,"sku":"MEH900R15","price":101.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh900r_626b020d-5533-4857-8960-273077038dc4.jpg?v=1766400753"},{"product_id":"var-3817-microelectrode-holder-meh900s","title":"Microelectrode Holder (MEH900S)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eMale Connector\u003c\/li\u003e\r\n\u003cli\u003ePellet Half-Cell\u003c\/li\u003e\r\n\u003cli\u003e2.0mm Pressure Port\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 120px; width: 368px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 208px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 147px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 208px;\"\u003e MEH900S10\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 147px;\"\u003e1.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 208px;\"\u003e MEH900S12\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 147px;\"\u003e1.2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #ffffff;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 208px;\"\u003e MEH900S15\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 147px;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eHolder\/Half-cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266281115738,"sku":"MEH900S10","price":86.0,"currency_code":"USD","in_stock":true},{"title":"1.2 mm","offer_id":42266281148506,"sku":"MEH900S12","price":86.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266281181274,"sku":"MEH900S15","price":86.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh900s_b4b69465-3d53-423b-bab7-ab133664b344.jpg?v=1766400767"},{"product_id":"var-3818-microelectrode-holder-mph1","title":"Microelectrode Holder (MPH1)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eFemale Luer\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 49px; width: 328px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 161px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 151px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 161px;\"\u003e MPH110\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 151px;\"\u003e1.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 161px;\"\u003e MPH112\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 151px;\"\u003e1.2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #ffffff;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 161px;\"\u003e MPH115\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 151px;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 161px;\"\u003e MPH120\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 151px;\"\u003e2.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eMounting on a Micromanipulator\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eSome non-WPI preamplifiers or headstages cannot be mounted on micromanipulators. In such cases, a holder equipped with a rod (e.g., MEH8) permits the holder to be conveniently mounted on a micromanipulator.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eHolder\/Half-cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266281246810,"sku":"MPH110","price":180.0,"currency_code":"USD","in_stock":true},{"title":"1.2 mm","offer_id":42266281279578,"sku":"MPH112","price":180.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266281312346,"sku":"MPH115","price":180.0,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":42266281345114,"sku":"MPH120","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/mph1_5d83d4ae-f747-422f-bf61-9df598d32e8a.jpg?v=1766400784"},{"product_id":"var-3819-microelectrode-holder-mph3","title":"Microelectrode Holder (MPH3)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\r\n\u003cli\u003eMale Luer\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 49px; width: 322px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 168px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 138px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 168px;\"\u003e MPH310\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 138px;\"\u003e1.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 168px;\"\u003e MPH312\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 138px;\"\u003e1.2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #ffffff;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 168px;\"\u003e MPH315\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 138px;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 168px;\"\u003e MPH320\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 138px;\"\u003e2.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eMounting on a Micromanipulator\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eSome non-WPI preamplifiers or headstages cannot be mounted on micromanipulators. In such cases, a holder equipped with a rod (e.g., MEH8) permits the holder to be conveniently mounted on a micromanipulator.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eHolder\/Half-cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266281508954,"sku":"MPH310","price":83.0,"currency_code":"USD","in_stock":true},{"title":"1.2 mm","offer_id":42266281541722,"sku":"MPH312","price":83.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266281574490,"sku":"MPH315","price":83.0,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":42266281607258,"sku":"MPH320","price":83.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/mph3_d2db7217-dcd8-404b-9fec-0f81708f6147.jpg?v=1766400802"},{"product_id":"var-3820-microelectrode-holder-mph4","title":"Microelectrode Holder (MPH4)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e2.0mm Pressure Port\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 49px; width: 318px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 166px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 136px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 166px;\"\u003e MPH410\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 136px;\"\u003e1.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 166px;\"\u003e MPH412\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 136px;\"\u003e1.2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #ffffff;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 166px;\"\u003e MPH415\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 136px;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 166px;\"\u003e MPH420\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 136px;\"\u003e2.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI™s microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\", 3\/32\", 1\/8\", 5\/32\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eMounting on a Micromanipulator\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eSome non-WPI preamplifiers or headstages cannot be mounted on micromanipulators. In such cases, a holder equipped with a rod (e.g., MEH8) permits the holder to be conveniently mounted on a micromanipulator.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eHolder\/Half-cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266281705562,"sku":"MPH410","price":83.0,"currency_code":"USD","in_stock":true},{"title":"1.2 mm","offer_id":42266281738330,"sku":"MPH412","price":83.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266281771098,"sku":"MPH415","price":83.0,"currency_code":"USD","in_stock":true},{"title":"2.0 mm","offer_id":42266281803866,"sku":"MPH420","price":83.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/mph4_8c539c7f-ee57-43db-9d4c-64e03b2f57eb.jpg?v=1766400824"},{"product_id":"var-3821-microelectrode-holder-mph6p","title":"Microelectrode Holder (MPH6P)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eMale Connector\u003c\/li\u003e\r\n\u003cli\u003ePellet Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eFemale Luer\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 87px; width: 336px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 193.111px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 136.179px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 193.111px;\"\u003eMPH6P10\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 136.179px;\"\u003e1.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 193.111px;\"\u003eMPH6P12\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 136.179px;\"\u003e1.2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd style=\"text-align: left; width: 193.111px;\"\u003eMPH6P15\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 136.179px;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI's microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard “syringe-style” luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\"\u003eHolder\/Half-cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266283212890,"sku":"MPH6P10","price":93.0,"currency_code":"USD","in_stock":true},{"title":"1.2 mm","offer_id":42266283278426,"sku":"MPH6P12","price":93.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266283245658,"sku":"MPH6P15","price":93.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/mph6p_2579ae61-eb07-4347-83d3-f70c226aadea.jpg?v=1766400843"},{"product_id":"var-3822-microelectrode-holder-mph6r","title":"Microelectrode Holder (MPH6R)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eMale Connector\u003c\/li\u003e\r\n\u003cli\u003eWire Half-Cell\u003c\/li\u003e\r\n\u003cli\u003eFemale Luer\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 120px; width: 329px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 171.4px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 143.6px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 171.4px;\"\u003e MPH6R10\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 143.6px;\"\u003e1.0 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 171.4px;\"\u003e MPH6R12\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 143.6px;\"\u003e1.2 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #ffffff;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 171.4px;\"\u003e MPH6R15\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 143.6px;\"\u003e1.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eWPI's microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eElectrical Connections \u0026amp; angle\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRubber gasket vs Screw cap\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePellet vs Wire\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePressure Port Choices\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard “syringe-style” luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHolder\/Half Cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266283475034,"sku":"MPH6R10","price":83.0,"currency_code":"USD","in_stock":true},{"title":"1.2 mm","offer_id":42266283409498,"sku":"MPH6R12","price":83.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266283442266,"sku":"MPH6R15","price":83.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/mph6r_a0bfc1af-fe75-4132-b9f8-e1f9a4df0ef7.jpg?v=1766400859"},{"product_id":"var-8004-microelectrode-holder-meh6sfw","title":"Microelectrode Holder (MEH6SFW)","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eFemale Connector\u003c\/li\u003e\r\n\u003cli\u003eWire Half-Cell\u003c\/li\u003e\r\n\u003cli\u003e2.0mm Pressure Port\u003c\/li\u003e\r\n\u003cli\u003eScrew Cap\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch2\u003eOptions\u003c\/h2\u003e\r\n\u003ctable style=\"height: 109px; width: 380px;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr style=\"background-color: #0081c2;\"\u003e\r\n\u003ctd style=\"text-align: center; width: 188px;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eOrder code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd style=\"text-align: center; width: 177px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 188px;\"\u003eMEH6SFW10\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 177px;\"\u003e1.0 mm OD\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"text-align: center;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 188px;\"\u003eMEH6SFW12\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 177px;\"\u003e1.2 mm OD\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr style=\"background-color: #e4e4e4;\"\u003e\r\n\u003ctd style=\"text-align: left; width: 188px;\"\u003eMEH6SFW15\u003c\/td\u003e\r\n\u003ctd style=\"text-align: left; width: 177px;\"\u003e1.5 mm OD\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eDetails\u003c\/h2\u003e\r\n\u003cp\u003eFor use with these WPI Products: SYS-705, SYS-773, 767, 721, FD223\u003c\/p\u003e\r\n\u003cp\u003eAll holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. Please specify diameter of glass you are using when placing your order.\u003c\/p\u003e\r\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cp\u003eWPI's microelectrode holder-half-cells couple fluid-filled glass micropipettes to high input impedance amplifiers. A Ag\/AgCl pellet (or a silver wire) molded into the holder body provides stable potential. Electrical connection is made via male 2 mm pins or female 2 mm sockets. The pipette may be mounted axially or at right angles to the holder. Pipettes are held with screw-caps or rubber gaskets (without caps). Filling WPI microelectrode holders with electrolytes containing chloride results in stable electrode potential. Suitable electrolytes include KCl, NaCl and CaCl2. Holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. (Call WPI regarding custom designs for other glass diameters.) The holder style you select will depend on your experimental application, space, and instrumentation.\u003c\/p\u003e\r\n\u003ch2\u003eElectrical Connections \u0026amp; angle\u003c\/h2\u003e\r\n\u003cp\u003eDetermine the required electrical connection on the holder: for example, if you wish to connect the holder to a 2 mm pin you should select a holder equipped with a 2 mm jack. Most WPI probes require a holder equipped with a 2 mm jack. Decide on the required alignment of the electrical connection: either in-line with the glass pipette, or at a right angle to it. Space considerations in your experimental setup and requirements imposed by other pieces of equipment typically determine which alignment is appropriate.\u003c\/p\u003e\r\n\u003ch2\u003eRubber gasket vs Screw cap\u003c\/h2\u003e\r\n\u003cp\u003eDetermine if you want to hold the glass pipette by a rubber gasket (e.g., MEH1S) or a screw-cap (e.g., MEH3S). Rubber gaskets offer easier insertion and removal of glass pipettes whereas screw-caps provide more secure mounts for micropipetters.\u003c\/p\u003e\r\n\u003ch2\u003ePellet vs Wire\u003c\/h2\u003e\r\n\u003cp\u003eChoose a holder with either a silver wire or a silver\/silver chloride pellet for the metal\/liquid coupling. Silver\/silver chloride pellets provide a more stable low-noise baseline which is important for low-noise DC recording. Pellets require the glass pipette and holder to be free of air bubbles to achieve a good connection. Silver wire holders are durable and are easier to use when the holder is equipped with a pressure port because the fluid in the pipette does not have to be filled to the top of the pipette to achieve a good electrical connection\u003c\/p\u003e\r\n\u003ch2\u003ePressure Port Choices\u003c\/h2\u003e\r\n\u003cp\u003eChoose a holder equipped with a pressure port only when you want to pressure inject liquid from the pipette. Two types of ports are available: 2.0 mm O.D. and standard \"\"syringe-style\"\" luer. The luer port is often recommended because it makes assembly and disassembly much easier. Quick-connect luer fittings for four common sizes of tubing (1\/16\"\", 3\/32\"\", 1\/8\"\", 5\/32\"\" I.D.) are included with each luer-equipped holder.\u003c\/p\u003e\n\u003c!-- \/section:details --\u003e\n\n\u003c!-- section:resources --\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/holder-half-cells-im.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHolder\/Half Cells Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/section:resources --\u003e","brand":"World Precision Instruments","offers":[{"title":"1.0 mm","offer_id":42266343145562,"sku":"MEH6SFW10","price":100.0,"currency_code":"USD","in_stock":true},{"title":"1.2 mm","offer_id":42266343080026,"sku":"MEH6SFW12","price":100.0,"currency_code":"USD","in_stock":true},{"title":"1.5 mm","offer_id":42266343112794,"sku":"MEH6SFW15","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/meh6sfw_5359c23d-feee-4a31-8f6d-2d6b311a9132.jpg?v=1766402327"},{"product_id":"5371-low-noise-cable-for-microelectrode-holder-a-pin-b-pin","title":"Low-noise cable for Microelectrode Holder, A: pin, B: pin","description":"\u003c!-- section:details --\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eUse as 2 mm pin-socket to 2 mm pin-socket or with 2 mm tip-plug stackable\u003c\/li\u003e\r\n\u003cli\u003eCable: 2 ft (0.6 m)\u003c\/li\u003e\r\n\u003c\/ul\u003e\n\u003c!-- \/section:details --\u003e","brand":"World Precision Instruments","offers":[{"title":"Default Title","offer_id":42266446430298,"sku":"5371","price":20.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/7993\/1994\/files\/5371_2181.jpg?v=1766405332"}],"url":"https:\/\/wpiinc.com\/collections\/micropipette-holders.oembed","provider":"World Precision Instruments","version":"1.0","type":"link"}